Heatless Regenerative Air Dryers

Similar documents
HEATLESS DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL

EXHAUST PURGE DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL MODEL RE-231 THROUGH RE-252

Heated Desiccant Air Dryer

WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS

NON-CYCLING REFRIGERATED AIR/GAS DRYERS QPNC 75 to QPNC 250 OPERATOR S MANUAL

HEATLESS REGENERATIVE DRYERS

Heatless Regenerative Compressed Air Dryers. Compressed Air System Products. Made in America

HEATLESS REGENERATIVE COMPRESSED AIR DRYER models THL-200 through THL- 5000

MR Series Heatless Mini Regenerative Desiccant Dryer. Operator s Manual

Fred C. Gilbert Co. 106 Norris Road Bakersfield, Ca fax

INGERSOLLrAND AIR COMPRESSORS CAUTION: HMD SERIES AIR DRYERS MODELS 18 THROUGH 385 OPERATORS/ INSTRUCTION MANUAL REPLACEMENT PARTS

DHW Series INSTRUCTION MANUAL. Pressure Swing Desiccant Compressed Air Dryer Models 7 through 50 scfm

DESICCANT DRYER USER MANUAL

MDH Series Air Dryer. User s Guide

Dry Air Pac ENGINEERED COMPRESSED AIR DRYING SYSTEMS FOR COLD STORAGE/ FREEZER ROOM DRY PIPE SPRINKLER SYSTEMS

Single Tower Heat Reactivated Desiccant Air Dryer

Installation, Operation, and Maintenance Instructions. Heatless Regenerative Air Dryers and HLD-PAK Dryer/Filter Packages HLD-25 through HLD-6250

Operation and Maintenance Manual. Dryer Package. Model Number: Job Number: Date Shipped: Date Started Up: Electrical: 120 V single phase - AC

VSA Series Air Dryer. User s Guide

HS Dryer. Smart Solutions for Drying Compressed Air. Single Tower Heat Reactivated Desiccant Air Dryer. Engineered Air Products

HS Dryer. Smart Solutions for Drying Compressed Air. Single Tower Heat Reactivated Desiccant Air Dryer. Engineered Air Products

Overview of HL series heatless regenerative dryers.

Dual Tower Heat Reactivated Desiccant Air Dryer

Owners Manual Refrigerated Air Dryer MHT SERIES

OPERATING MANUAL MODEL AIR 1500TM AIR DRYER

150-3,000 scfm AEHD Series. Desiccant Air Dryers AEHD Series. Externally Heated Desiccant Air Dryer 150-3,000 scfm. Front Page

Regenerative Desiccant Dryers. KAD, KED, KBD and Hybritec Series

DRY-PAK INDUSTRIAL AIR DRYER Installation and Instruction Manual

DESICCANT DRYER USER MANUAL

Laboratory Enclosed Rotary Screw Air Compressor System with Air Treatment Center Package

SECTION AIR COMPRESSORS AND ACCESSORIES

DGH Series Global Air Treatment

Corrosion Dry Air Pak

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer

DESICCANT DRYER USER MANUAL

AirCel. Heated Regenerative Desiccant Dryers. AEHD Externally Heated, HRE Blower Purge, and HRS-L Zero Purge Series

Desiccant Air Dryers. ABP Series. Blower Purge Desiccant Air Dryer 70-8,000 scfm

Quality Components as a basis for Quality Equipment

ECLIPSE DESICCANT DRYERS ZHA HEATED PURGE MODELS

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350

Owner s Manual Refrigerated Compressed Air Dryers Model F-100

Externally Heated Exhaust Purge Regenerative Compressed Air Dryer

CDT Series MCGUIRE AIR COMPRESSORS INC MCGUIRE AIR COMPRESSORS INC Heatless Desiccant Air Dryers 40 5,400 SCfm

INSTALLATION, OPERATION & MAINTENANCE MANUAL FOR PREP-40 PORTABLE COMPRESSED AIR DRYER SYSTEM model FR-800 (P/N )

MODEL MW200 MODEL MW600 AIR DRYER

Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls

SERIES HC Heat-of-Compression Compressed Air Dryer

GRF-SERIES REFRIGERATION TYPE NON CYCLING STANDARD

INSTALLATION, OPERATION & MAINTENANCE MANUAL FOR DRY PAK PACKAGED COMPRESSED AIR TREATMENT SYSTEM MODEL: DPP-150 WARNING

ZPA Heatless Regeneration ZHA Heated Regeneration ZBA Heated Blower Regeneration

Desiccant Dryers. Desiccant Dryers. Heatless Heated Purge Blower Purge Modular

Equipment Designed for Industrial Applications

Desiccant Air Dryers. Heatless, Heated and Heated Blower

HEATLESS DESICCANT AIR DRYERS

Owner s Manual Refrigerated Compressed Air Dryer Model F-50

Desiccant Air Drying Technologies HCS Series HCL Series HCT Series

EN Installation and Operation Manual

ZERO AIR GENERATOR MODEL 7000 INSTRUCTION MANUAL

Refrigerated & Desiccant Compressed Air Dryer Product Selector

SSB Blower Purge Desiccant Dryers SSE Heat Reactivated Desiccant Dryers 220 to 10,500 scfm

NEWGATE TECHNOLOGIES, INC.

CDH Series Heatless Desiccant Dryers CFM

SERIES 101T MOISTURE ANALYZER QUICK START GUIDE

SULLAIR DESICCANT DRYERS

Trident Breathing Air System

(PD[ $LU 'U\HU 5 ( ) 5, * ( 5 $ 7 ( ' 7 < 3 ( & ( 6 6 ( ' $, 5 ' 5 < ( 5 6 ('5&) ದ ('5&) Instructions Manual

CLEAN, DRY COMPRESSED AIR

Rev. A AUGUST 2012 RNP SERIES REFRIGERATED COMPRESSED AIR DRYERS OPERATOR MANUAL RNP25 RNP35 RNP50

10/09/2014. SFD Air Dryer Owner s Manual

Polar Air Dryer. Instructions Manual PDRCF PDRCF R E F R I G E R A T E D T Y P E C O M P R E S S E D A I R D R Y E R S

Desiccant Drying DRYPOINT XC. efficient low dew point heatless desiccant drying. Truth in Compressed Air.

COMPRESSED AIR DRYER INSTRUCTION MANUAL BLOWER PURGE DESICCANT DRYERS. Contents

P6500W Air Dryer User s Guide

Dual Column Dehydrating Breather Manual

DESICCANT AIR DRYERS. BD + CD + CD series

Moduflex. Desiccant Air Dryer P3TJA13A1AN - P3TJA13A7AN. USER GUIDE (Original Language) Dry Air System NL DE FR FI SV NO DA EL ES PT IT PL SK CS ET HU

HTD. High Temperature Non-Cycling Refrigerated Compressed Air Dryers. Operation & Maintenance Manual. MODELS HTD 21 thru HTD 100

Heat Les Desiccant Compressed Air Dryers. DSE Series DSS Series DHD Series

Owners Manual UA75 TO UA1200 SERIES Refrigerated Air Dryer

Owner s Manual Refrigerated Compressed Air Dryers Models F-3528, F-3529, F-3530, F-3531 & F-3532

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

DESICCANT AIR DRYERS. BD + CD + CD series

DRYMAX DRYMAX DRYMAX DRYMAX

DRY AIR SYSTEMS, INC Metro Boulevard Maryland Heights, Missouri (314) fax (314)

Condensate Drain Valves

POD Silo Dehumidifier Series. with Logo! TM PLC POD-150 DOCUMENT: POD IM 14 DEC NOVATEC, Inc All Rights Reserved

ultra-high purity compressed air dryers flow capacity: scfm ( Nm 3 /hr)

TWP & TWB Series Externally Heated and Blower Purge Desiccant Air Dryers

P4200PM / P5000PM Remote Air Dryer User s Guide

INSTRUCTION MANUAL FOR LECTRODRYER BAC-50 HYDROGEN DRYING SYSTEM. Lectrodryer Serial Number:

MDX. Non-Cycling Refrigerated Compressed Air Dryers with zero-loss Intellidrain Drain Trap. Operation & Maintenance Manual MDX MODELS 18 THRU 250

OPERATING INSTRUCTIONS AND PARTS LIST FOR. P05860-H2 (heatless) Nitrogen Bottle Replacement Unit

Regenerative Desiccant Dryers. KAD, KED, KBD, and Hybritec Series. kaeser.com

MDX. Non-Cycling Refrigerated Compressed Air Dryers with zero-loss Intellidrain. Operation & Maintenance Manual MODELS MDX

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

Titus Air Systems. TDD Series. The need for clean and dry compressed air. Energy efficiency

Unique, Energy-Saving Models HC & SP World Leader in Regenerative Dryer Technology

Reciprocating Instrument Air System. Installation Operation and Maintenance Manual 5-20 Hp

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N

Transcription:

Heatless Regenerative Air Dryers CPAD Series / CPADM Series Owner s Manual Jan. 2009

DATE OF PURCHASE MODEL SERIAL NO. Record above information from nameplate. Retain this information for future reference. 1

TABLE OF CONTENTS General Information 4 Receiving Inspection 4 Safety Instructions 4 Disclaimer of Warranty 5 Desiccant Replacement Procedures 6 Filling Procedure 6 Molecular Sieve Option 6 Draining Procedure 6 Desiccant Disposal 6 Installation & Operation 7 CPAD Series Heatless Air Dryer Installation & Operation General 8 Start-Up Procedure 8 Adjustments 9 DMP Microprocessor Control with Cycle Knight 9 Sequence of Operation 10 Shutdown Procedure 11 CPADM Mini Series Heatless Air Dryer Installation & Operation General 13 Theory of Operation 13 Start-Up Procedure 13 Operational Observation 13 Maintenance 14 CPAD Series Heatless Air Dryer Maintenance General 14 Daily 14 Weekly 14 Monthly 14 Three Months 14 Twelve Months 14 Dewpoint Sensor (Optional) 14 Mufflers 14 CPADM Mini Series Heatless Air Dryer Maintenance General 15 Daily 15 Weekly 15 Three Months 15 Twelve Months 15 Mufflers 15 Desiccant Replacement Procedure 15 Desiccant Disposal 15 2

Dewpoint Display Key Functions 17 Setting Point and Programming 17 Measurement Range 17 Options Listing with Explanation (CPAD Only) 19 Audible Alarm 19 Failure to Shift Alarm 19 High Humidity Alarm 19 Moisture Indicator 19 Panel Lights 19 PLC Controller 19 Dewpoint Demand Control DPD 19 Troubleshooting 20 3

GENERAL INFORMATION The Chicago Pneumatic Drying System is designed to remove moisture from compressed air. When properly installed, the unit requires little maintenance or adjustment. A list of service parts is provided on the attached parts list. WARNING DO NOT install, operate, maintain, adjust or service this unit without thoroughly reading this manual. This manual contains important safety information. Read THOROUGHLY and follow the Safety Instructions provided in this manual and posted on the unit. Keep this manual near the unit and in a safe place. Replace this manual if it becomes torn or dirty and cannot be properly used. Please read the Installation & Operation section of this manual before attempting to operate the unit. Please read the Maintenance and Troubleshooting sections of this manual before beginning any maintenance or service work on this unit. RECEIVING INSPECTION Inspect equipment. Any concealed shipping damage must be reported to the carrier immediately. Damage claims should be filed by the consignee with the carrier. SAFETY INSTRUCTIONS When using air compressors and compressed air accessories, basic safety rules and precautions must always be followed, including the following: 1. READ ALL INSTRUCTIONS FULLY. 2. WIRING & BREAKERS Wiring, breakers and other electrical equipment must conform to local and national electrical codes. Do not operate this unit with damaged wiring or after the unit or air handling parts have been dropped or damaged in any manner. Notify authorized service facility for examination, repair or other adjustments. WARNING Comply with the National Electrical Code, Federal, State and Local Codes when installing or operating this unit. 3. USE SUITABLE PARTS & ACCESSORIES Do not use air pressurized accessories or parts in the air system not suitable for the maximum air pressure used. Be sure maximum pressure specified by the accessory manufacturer is well above the working pressure of your compressor. 4. RELEASE AIR PRESSURE SLOWLY Fast moving air will stir up dust and debris, which may be harmful. Release air pressure slowly when depressurizing your system to avoid bodily injury. All the equipment shipped F.O.B. becomes the property of the purchaser. In all cases of damage, visible or suspected, contact your local distributor or Chicago Pneumatic before attempting to install equipment. SERVICE INQUIRIES: Provide Model No., Serial No., Operating Pressure, Inlet Temperature, Nature of Problem. See Dryer Specification Tag located on the control panel. 4

5. SECURE DRAIN LINES Fasten drain lines from prefilter/separator to floor or drain. Pressurized air will periodically pass through drain lines, which will cause an unsecured line to whip and may cause bodily injury. WARNING Air from compressor and from air drying system, as equipped, is not safe for human respiration (breathing). To provide safe, breathable air, compressor must be capable of producing at least Grade D breathing air as described in Compressed Gas Association Commodity Specification G7.1-1966. Special filtering, purifying and associated alarm equipment must be used to convert compressed air to Breathing Air. Other special precautions must also be taken. DISCLAIMER OF WARRANTY If this unit is used to produce breathing air, the special equipment and precautions expressed in OSHA 29 CFR 1910.134 for specifications of the necessary equipment and special precautions to make Breathing Air MUST BE used or any warranties are VOID and manufacturer disclaims any liability whatsoever for loss, personal injury or damage. CAUTION Connect oil coalescing prefilter with automatic drain before the dryer to prevent any oil or slugs of water carryover into the desiccant. Connect particulate afterfilter downstream of the dryer to retain any desiccant dust flowing into the process air lines. Refer to OSHA 29 CFR 1910.134. 5

DESICCANT REPLACEMENT PROCEDURES Chicago Pneumatic uses Activated Alumina Grade A desiccant for all standard heatless air dryers. Dryers up to 1500 SCFM are factory filled with desiccant. Dryers 1800 SCFM and larger are supplied with loose desiccant in 50 lb. bags. The dryer must be filled with desiccant before start-up. Dryers ranging from 5 SCFM to 500 SCFM use 1/8" diameter desiccant. Dryers 650 SCFM and larger use a mix of 1/8 and 1/4" size desiccant. See the dryer specification sheet or dryer data tag for amounts per tower. FILLING PROCEDURE For CPADM models refer to Page 15. 1. Make sure the dryer is depressurized. 2. Remove the plugs or flanges from the fill ports located on the top of the pressure vessels. 3. Using a flashlight, inspect the inside of each vessel to be sure they are empty. MOLECULAR SIEVE OPTION (LOW DEWPOINT) Dryers with optional Molecular Sieve are filled with the Activated Alumina first and the Molecular Sieve last. The Molecular Sieve is used as a polishing agent to lower the dewpoint temperature. NOTE: The proper amount of desiccant may or may not fill the vessel to the top. DRAINING PROCEDURE The desiccant can be removed by the two methods listed below. MAKE SURE THE DRYER IS DEPRESSURIZED PRIOR TO REMOVING THE FILL OR DRAIN PORT. Method #1 Remove the drain port and drain the desiccant into buckets which are then poured into the proper dumpster or receptacle. 4. Verify that the desiccant drain port located in the bottom of the pressure vessel is closed tightly. 5. Desiccant is available in 50# bags, or 300# barrels. Divide the desiccant into equal amounts for each tower, and verify the correct amount by the specification tag located on the electrical panel. Towers can be filled manually with desiccant bags. A fork lift or overhead crane should be used when filling with 300# barrels. 6. Dryers 650 SCFM and larger use two sizes of desiccant. For all heat reactivated models, fill the tower with the 1/4" diameter Activated Alumina first, followed by 1/8" Activated Alumina. The large desiccant (1/4 size) is used to disperse the inlet air flow. 7. Close the fill ports and put the dryer in service. Refer to the Start-Up Procedure listed in this manual. Method #2 Usually used for large dryers (1000 SCFM and larger). An industrial dry vacuum cleaner is required for this method. 1. Remove the desiccant fill port. 2. Using an industrial vacuum cleaner, remove the desiccant from the vessel. 3. Open the desiccant drain port and remove the remaining desiccant. DESICCANT DISPOSAL Desiccant is not considered a hazardous waste, unless contaminated with oil or other toxic substances. Disposal of the desiccant should be handled by a local waste management company. 6

INSTALLATION & OPERATION FIGURE 1 COMPRESSED AIR SYSTEM RECOMMENDED INSTALLATION FLOW DIAGRAM 7

CPAD SERIES HEATLESS AIR DRYER INSTALLATION & OPERATION General 1. Install dryer on a level base, indoors or under a shed. 2. During shipment, flange and connecting bolts can come loose. All bolts should be checked and tightened as needed. 3. Make sure when the piping is in place that no undue stress is placed on dryer connections. Union joints or flexible connections are recommended to relieve stress. Also, properly support the pipes as needed with hangers or brackets. Air piping must be installed by an experienced pipe fitter. 4. Equip dryer with inlet and outlet isolation valves and a bypass valve for ease of servicing and start-up. 5. Connect electric power to the dryer through a properly sized fused disconnect switch. 6. Reactivation exhaust may be piped away from the dryer, making sure proper pipe size is used. The pipe size should be increased by one size at the valve, and one additional pipe diameter size for every ten-foot run to reduce back pressure. 7. ELECTRICAL CONNECTIONS: Follow the recognized local and municipal electrical codes. All components must be load rated as approved by NEC, NEMA, CSA and UL. DANGER High voltage could cause death or serious injury. Disconnect all power supplies before installing or working on electrical components. 8. During shipment, wire connections may become loose. Per U.L. specification, torque screws inside enclosure to 20 in-lbs. 9. GROUNDING: It is mandatory that the dryer be grounded. Use an adequate ground with the conductor sized to NEC. 11. LEAK TEST: All the dryers are tested at the factory for any leaks before shipment. An air leak could develop during transportation or installation. Pressurize the system and check for any leaks. Start-Up Procedure 1. Keeping the dryer isolation outlet valve closed, slowly pressurize both the adsorbent chambers to the line pressure. 2. Check for any leaks in the system. 3. When both adsorbent chambers are at line pressure, push ON button. 4. One inlet valve will close, and one purge valve will open and depressurize one adsorbent chamber. This may take as long as 3 minutes. 5. Adjust the purge pressure to the recommended setting, and lock the valve locking mechanism in place. 6. Slowly open the dryer isolation outlet valve to pressurize the downstream system. 7. Observe the dryer operation through one or two complete cycles. Adjustments & Settings 1. Adjust the purge pressure to the recommended level PSIG. 2. Dewpoint Demand Setpoint: High Humidity Alarm Setpoint: (See dewpoint display settings on Page 17) DMP Microprocessor Control with Cycle Knight INTRODUCTION 1. GENERAL: The DMP controller is a microprocessor controlled, seven (7) channel sequence timer with LED display features. The DMP controller consists of the main control unit and a remote LED and timer. 10. STORAGE: In case of extended storage period before the installation, follow these simple procedures: a. Seal or cover all the parts b. Wrap the electrical enclosure c. Wrap the mufflers d. If the desiccant is shipped loose, store it inside to avoid any rain or water damage. 8

2. SEQUENCE OF OPERATION: The sequence of operation is based on a five (5) minute or ten (10) minute NEMA Cycle. For either cycle length, onehalf of the total time is for adsorption of moisture from the process gas and one-half is for desiccant regeneration. Specifics of the timing sequence are detailed in Figure 2, the Sequence of Operation Diagram (SDG-2). If power is interrupted and then reapplied, the DMP controller will start the timing at zero. At all times during operation, the current status of the timing cycle is indicated graphically by the LEDs. 3. FEATURES LED sequence annunciator indicating R/L tower drying/regenerating, demand cycle indicator (opt.), high humidity alarm (opt.), fail to shift alarm (opt.). 5 or 10 minute NEMA cycle selector Alarm reset button MODE OF OPERATION 1. START UP: The Digital Microprocessor Sequence Controller will start to operate as soon as the unit is turned on. The load outputs will recycle on and off based on a five (5) minute or ten (10) minute NEMA Cycle. The sequence will proceed according to the Sequence of Operation Diagram SDG-2. See Figure 2. The timing starts at zero. 2. NEMA CYCLE: The DMP Controller can be set to operate in a 5 minute NEMA Cycle or a 10 minute NEMA Cycle. The cycle can be selected via a slide switch at the back of the timer. 3. RELAY OUTPUTS (DRY CONTACTS): There are two relay outputs for remote annunciation. The output is normally open rated for 10 AMPS resistive at 125VAC, 5 AMPS resistive at 30VDC. The outputs are for the inhibit Failure to Switch and High Humidity. If one or both inhibits are made, the relays will be energized and the LED on the timer will light up. 4. ALARM LED AND RELAY OUTPUTS: These will only be reset by pushing the button. FIGURE 2 SDG-2: 10 MINUTE SEQUENCE OF OPERATION DIAGRAM 9

CAUTION This unit may be damaged by electrostatic discharge. Follow procedures for static sensitive parts when handling, shipping or installing this unit. OPTIONAL CONTROLS AND ALARMS 1. DEWPOINT DEMAND SEQUENCE CONTROL: The dewpoint demand mode function will be operational if there are 5 minutes before the end of the drying cycle, and the dewpoint is below the preset level. When in the dewpoint demand mode, all of the timing functions stop. The yellow LED on the timer will light up. When the dewpoint reaches the preset dewpoint level, the towers will switch and the normal mode cycle will commence. The dewpoint demand mode function will be disabled if the dewpoint is above the preset level or normal cycle is selected. 2. HIGH HUMIDITY: The high humidity alarm function is indicated by a red LED on the timer. The high humidity relay will energize for remote annunciation. All the normal functions will be maintained. 3. FAIL TO SHIFT: The fail to shift inhibit will be energized if the inhibit switch remains closed for 5 seconds beyond the normal cycle. Fail to shift will be indicated by the red LED on the timer and the fail to shift relay will be energized for remote annunciation. The fail to shift inhibit is an indication of a malfunction of the tower switching valves or purge exhaust valves. Sequence of Operation The sequence of operation of the Heatless Regenerative Dryer can be readily followed by referring to the following flow schematic on Page 12. The operation is fully automatic, controlled by the DMP, pneumatic timer or PLC controller. During initial start-up, before ON button is pushed and the towers pressurized with air, both inlet valves stay in the OPEN position and the purge valves stay in the CLOSED position. This type of fail safe valve operation allows the air to dry through both the towers, without any purge in the event of loss of power to dryer. This will give you extended drying time until desiccant chambers are saturated. At time equal to 0.0 minutes, the right tower air inlet valve is open to allow the air to pass through the right tower. The left tower inlet valve is closed. The saturated compressed air/gas passes through the desiccant in the right tower, where the desiccant adsorbs the moisture. The dry air, at a pressure dewpoint of -40 F/C or less, exits through the right outlet check valve and goes out into the plant air system through the afterfilter. At time equal to 0.1 minutes, the left tower purge valve opens to fully depressurize the desiccant bed, and commence the regeneration cycle. NOTE: As soon as the purge valve has opened, adjust the purge adjustment valve to the recommended purge control setting. This adjustment should only be required once, and then the locking mechanism should be locked in place. A portion of dry outlet air is diverted and passed through a series of regulating and flow control valves to meter the measured quantity of air for regeneration. The pressure of this purge air is regulated by the purge adjustment valve at the specified purge pressure on the meter gauge. This dry purge air at low pressure passes through the right purge check valve and is introduced into the right tower. The purge air picks up the moisture from the desiccant and exhausts into the atmosphere through the purge valve and purge muffler CAUTION Frost or ice development on the regenerating tower is a sign of low inlet air temperatures. Due to the expansion of the purge air, cooling may develop icing in the desiccant. Temperature of the purge air is determined by the temperature of the air during the drying cycle and should be greater than +70 F (> +70 F). Adsorption of moisture by the desiccant results in the release of heat of adsorption, which is retained in the bed to assist in desiccant regeneration. NOTE: During the regeneration air flow through the desiccant bed, the tower pressure gauge should read 0 PSIG. Any higher pressure is an indication of a plugged muffler, which will retard the regeneration of desiccant. The desiccant is designed to handle air saturated with water vapor only. Any liquids or slugs of water tend to decrease the efficiency of the desiccant and retard the regeneration process to provide the designed dewpoint. 10

At time equal to 4.3 minutes, the purge valve closes. The purge air entering the tower starts to repressurize the chamber. At time equal to 4.4 minutes, the repressurizing valve is energized to open and repressurize the tower to line pressure (standard with models 400 scfm and larger). At time equal to 5 minutes, the left tower inlet valve opens, and the right tower inlet valve closes, so the flow of wet air/gas is switched from right chamber to the left chamber. At time equal to 5.1 minutes, the right tower purge valve opens to commence the regeneration cycle and the above process is then repeated on the opposite towers Shutdown Procedure Heatless type dryers operate on a standard time cycle of 10 minutes, 5 minutes drying and 5 minutes regenerating. This cycle should not be interrupted. If the dryer needs to be shut down for a certain shift or weekend; the dryer should be turned off at the end of the 5 minute regenerating cycle, and with both towers at line pressure. If servicing is required advance the time sequence so the purge valves close, and pressurize both towers. At this time, the dryer can be turned off. 1. If the compressed air system has been piped with a bypass around the dryer, then the following should be completed: a. Open the bypass valve to allow process flow to continue downstream. Then close the dryer outlet isolation valve on the dryer bypass piping. b. Push the OFF button. c. Close the dryer inlet isolation valve on the dryer bypass piping. At this time the dryer is isolated and can be depressurized for servicing. 2. If the compressed air system has not been piped with a bypass, then the following should be completed: a. Push the OFF button. b. The tower switching valves are normally open valves; therefore, with the power off the inlet valves to the towers will be open, and the purge valves will close. This will give you extended drying time until desiccant chambers are saturated. For normal dryer shutdown, wait until both towers are at line pressure. At this time the purge valves will close. 11

FIGURE 3 CPAD SERIES HEATLESS AIR DRYER FLOW DIAGRAM 12

CPADM MINI SERIES HEATLESS AIR DRYER INSTALLATION & OPERATION General 1. If base mounted, secure base plate to hard surface, or hang securely on a wall. 2. Dryer should be installed indoors or under a shed. 3. Equip dryer with inlet and outlet isolation valves and a bypass valve for ease of servicing and start-up. 4. Connect electric power to the dryer through a properly sized fused disconnect switch. 5. Reactivation exhaust may be piped away from the dryer, making sure proper pipe size is used. For every ten-foot run, increase the pipe diameter by one size to reduce back pressure. 6. ELECTRICAL CONNECTIONS: Follow the recognized local and municipal electrical codes. All components must be load rated as approved by NEC, NEMA, CSA and UL. 7. During shipment, wire connections may become loose. Per UL specification, torque screws inside enclosure to 20 in-lbs. 8. GROUNDING: It is mandatory that the dryer be grounded. Use an adequate ground with the conductor sized to NEC. 9. STORAGE: In case of extended storage period before the installation, follow these simple procedures: a. Seal or cover all the parts b. Wrap the electrical enclosure c. Wrap the mufflers d. If the desiccant is shipped loose, store it inside to avoid any rain or water damage. 10. LEAK TEST: All the dryers are tested at the factory for any leaks before shipment. An air leak could develop during transportation or installation. Pressurize the system and check for any leaks. Drying: 5 minutes Regeneration: 4 minutes, 20 seconds (continuous flow) Repressurizing: 40 seconds While one adsorbent filled tower is drying the inlet flow at the line pressure, in the upward direction for 5 minutes, the other tower goes through a mode of desiccant regeneration in counter flow for 4 minutes, 20 seconds. Start-Up Procedure 1. Leave the dryer power supply disconnected. 2. Keeping the dryer isolation outlet valve closed, slowly pressurize both the desiccant chambers to the line pressure. 3. Check for any leaks in the system. 4. Purge valve should be closed at this time (N.C. vavle) 5. Connect the dryer power supply 6. The purge valve should open and depressurize one desiccant chamber. 7. Run the dryer through one or two cycles before slowly opening the dryer isolation outlet valve. Operational Observation 1. The drying chamber should be at the line pressure indicated on the drying chamber pressure gauge. 2. The reactivation chamber should be at 0 PSIG. (Any higher pressure is an indication of some malfunction; refer to Troubleshooting Guide on Page 20.) 3. The standard time cycle is 10 minutes. While one chamber is drying for 5 minutes the other chamber goes through a mode of desiccant reactivation and purge for about 4.3 minutes. The purge exhaust valve then closes to allow the chamber to repressurize to line pressure before switch-over occurs at the end of 5 minutes. Theory of Operation The CPADM Mini Series Heatless Regenerative Air Dryer features State of the Art design. The 4-way inlet valve and outlet shuttle valve make these dryers troublefree in operation and require very little maintenance. Standard Heatless Regenerative Air Dryers operate on a 10 minute NEMA cycle. 13

CPAD SERIES HEATLESS AIR DRYER MAINTENANCE WARNING Disconnect power and depressurize the dryer completely before starting maintenance procedures. General During the first month, clean or replace the pilot air filter element and repeat periodically. Also, clean the exhaust mufflers. Replace mufflers if the tower pressure gauge reads any back pressure during the regeneration cycle. No lubrication is required for any system. Daily Check auto drain on prefilter every shift. Weekly 1. Check the dryer s sequence of operation, and valve operation. 2. Check the purge control setting. 3. Check the operating conditions; inlet pressure, inlet temperature and the flow rate. 4. Check the moisture indicator. ORANGE color indicates DRY conditions. If the color is TRANSLUCENT, refer to the moisture indicator chart on alarm conditions for probable cause. (Optional equipment) 5. Check the purge mufflers for blockage. Possible indication is back pressure on tower under regeneration. Replace if necessary. 6. Check the pressure drop across prefilter and afterfilter. Replace the elements when the differential reaches 5-10 PSID. Monthly Check the pilot air filter element. Replace if necessary. Three Months 1. Every three (3) months, close the purge adjusting valve momentarily to check for any leaks in the inlet and/or check valves indicated by air coming through the exhaust mufflers. MAINTENANCE 2. Check the prefilter and afterfilter elements for excessive clogging or possible damage. Replace as necessary. 3. Blow down relief valves. 4. Check outlet dewpoint conditions. Twelve Months 1. Close the inlet and outlet valves on the dryer or bypass the dryer and completely depressurize the dryer system. Open the desiccant fill port and check visually. If desiccant is contaminated with oil or broken, replace the desiccant. 2. Check for leaking check valves per Table 1 symptoms C & D in Troubleshooting Guide. Repair or replace as necessary. 3. Remove the inlet switching valves and purge exhaust valves. Clean and replace worn out seats and seals. 4. Inspect the pilot air cylinders for leaks or worn out seals. Repair or replace as necessary. 5. Check repressurizing valve. Repair or replace as necessary. 6. Check pilot air solenoid valves for possible defects. Dewpoint Sensor (Optional) It is recommended to recalibrate the sensor probe annually to maintain accuracy. Contact your local distributor or factory for exchange policy. Calibration: To maintain accuracy, replace the probe every two years. Probe Replacement: Turn the normal/demand selector switch to the normal position. This will disable the contacts for Dewpoint Demand. Isolate and depressurize the probe chamber. Remove, and replace the probe. Pressurize the probe chamber and connect the sensor cable. A small amount of sample air (approximately 2-10 SCFH) should expel out the chamber needle valve. Mufflers Purge mufflers are installed to reduce the noise level. The mufflers tend to plug up and increase back pressure over time due to oil carryover and contaminants from compressor, or due to desiccant dust at the initial startup. To eliminate back pressure, replace muffler after three months, or when the back pressure increases in the regenerating tower. 14

CPADM MINI SERIES HEATLESS AIR DRYER MAINTENANCE WARNING Disconnect power and depressurize the dryer completely before starting maintenance procedures. General Clean the exhaust mufflers. Replace mufflers if there is any back pressure on the tower in the regeneration cycle. No lubrication is required, or should be used on any of the components. Daily 1. Check auto drain on prefilter every shift. 2. Follow the start-up procedure. Weekly 1. Check the shifting, purge and repressurization operation. 2. Check the operating conditions; inlet pressure, inlet temperature and the flow rate. 3. Check the moisture indicator. ORANGE color indicates DRY conditions. If the color is TRANSLUCENT, refer to the Troubleshooting Guide on Page 20 for probable cause. (Optional equipment.) 4. Check the purge mufflers for blockage. Possible indication is back pressure on tower under regeneration. Replace if necessary. 5. Check the pressure drop across prefilter and afterfilter. Replace the elements if the pressure drop exceeds 7 PSID. Three Months 1. Check the prefilter and afterfilter elements for excessive clogging or possible damage. Replace as necessary. 2. Check outlet dewpoint conditions. Twelve Months 1. Close the inlet and outlet valves on the dryer or bypass the dryer and completely depressurize the dryer system. Open the desiccant fill port and check visually. If desiccant is contaminated with oil or broken, replace the desiccant. 2. Inspect and clean the 4-way switching valve, purge solenoid valve and shuttle valve. Repair or replace as necessary. Mufflers Purge mufflers are installed to reduce the noise level. The mufflers tend to plug up and increase back pressure over time due to oil carryover and contaminants from compressor, or due to desiccant dust at the initial startup. To eliminate back pressure, replace muffler after one month of operation, and/or when the back pressure increases to 5 PSIG in the regenerating tower. Desiccant Replacement Procedure Activated Alumina Grade A 1/8 diameter is used for all standard CPADM Mini Series Heatless Regenerative Air Dryers. Filling Procedures: 1. Make sure the dryer is depressurized. 2. Remove the upper and lower interconnecting pipe and valves. 3. Remove the desiccant retaining screens on both ends of the desiccant chambers. Remove all desiccant. 4. Using a flash light, inspect the inside of each vessel to be sure they are empty. 5. Install the bottom desiccant screens and make sure they are secured tightly. 6. Begin filling the towers. 7. Install the top desiccant screens, and all of the interconnecting pipe and valves. 8. Refer to the star-up procedure listed in the manual. Desiccant Disposal Desiccant is not considered a hazardous waste, unless contaminated with oil or other toxic substances. Disposal of the desiccant should be handled by a local waste management company. 15

FIGURE 4 CPADM MINI SERIES HEATLESS AIR DRYER FLOW DIAGRAM 16

DEWPOINT DISPLAY KEY FUNCTIONS MEASUREMENT RANGE 1. Max. value: +68 o F 2. min. value: -148 o F Error Messages. ErrL = Open circuit, Sensor disconnected. ErrH = Over Range. FIGURE 5 DIGITAL DISPLAY SETPOINT PROGRAMMING Dryer with dew point demand option: Alarm set-point values are refereed to as ALr1 and ALr2 in the menu. To access the relevant alarm set-point, press the SET button once for ALr1 and twice for ALr2. To adjust the set-point press one of the ARROW buttons. The display will now flash the current set-point. Use the ARROW buttons to adjust to the required value. Press the SET button and the new value will be saved. Pressing the P button will exit the alarm setting mode without saving the new value. Standard setting: 1. ALr1: -20 o F (high humidity alarm) 2. ALr2: -40 o F (dew point demand) Setting for models with low dew point option: 1. ALr1: -70 o F (high humidity alarm) 2. ALr2: -100 o F (dew point demand) 17

SENSOR BLUE GREEN RED AL2 - + ma Output AL N L Power FIGURE 6 DEWPOINT DEMAND (DPD) OPTION WIRING 18

OPTIONS LISTING WITH EXPLANATION (CPAD only) AUDIBLE ALARM The Audible Alarm consists of a buzzer with reset push button and ON/OFF selector switch. The audible alarm provides an audible warning to alert an operator that the dryer is not functioning properly. This option is used with options such as Failure to Shift Alarm or High Humidity Alarm. FAILURE TO SHIFT ALARM The Failure to Shift Alarm consists of an alarm light that illuminates if the desiccant towers fail to shift at a prescribed time. Dry contacts are provided for remote annunciation. HIGH HUMIDITY ALARM The High Humidity Alarm consists of an alarm light controlled by a hygrometer that senses the dewpoint at the outlet of the air dryer. This alarm illuminates when the dewpoint reaches -20 F (-29 C) and above. A small amount of sample air is required for operation. Dry contacts are provided for remote annunciation. Calibration: To maintain accuracy, replace the probe every two years. Probe Replacement: Turn the normal/demand selector switch to the normal position. This will disable the contacts for Dewpoint Demand. Isolate and depressurize the probe chamber. Replace the probe. Pressurize the probe chamber and turn the power back on. MOISTURE INDICATOR The moisture indicator consists of a small, clear, polycarbonate filter filled with a color change silica gel. It is located at the outlet of the dryer. When the dewpoint is below -10 F (-23 C), the desiccant is deep orange. When the dewpoint is above -10 F (-23 C), the desiccant is translucent. A small amount of sample air is required for operation. FILTER HOUSING SILICA GEL PANEL LIGHTS The Panel Light option consists of four lights: Left Tower Drying, Right Tower Drying, Left Tower Regenerating, and Right Tower Regenerating. These lights are for dryer sequence indication. PLC CONTROLLER PLC Controller can also be added to control the operation of standard regenerative dryers. Typically Square D or Allen Bradley PLCs are used. DEWPOINT DEMAND CONTROL DPD The Dewpoint Demand control is an energy saver that can extend the drying cycle without purging, during periods of lower moisture loads. The Dewpoint Demand system offers, in one compact package, the utmost in flexibility and accuracy sensing the actual dewpoint of the outlet air. The hygrometer senses the dewpoint at the outlet of the dryer at the end of the drying cycle, and extends the drying cycle until the preset adjustable dewpoint setpoint is reached. During this extended drying cycle, the purge valves are closed and the opposite tower is pressurized and prepared for the drying cycle. The dewpoint demand option reduces purge loss and extends valve life. This option consists of the following: Digital Dewpoint Display Adjustable Setpoints Demand Cycle Light High Humidity Alarm Light with Dry Contact 4-20mA Output Calibration: To maintain accuracy, the probe should be recalibrated annually. Recalibrated probes are available through your local distributor. Probe Replacement: Isolate and depressurize the probe chamber. Disconnect the sensor cable from the sensor. Remove, and replace the probe. Pressurize the probe chamber and connect the sensor cable. A small amount of sample air (approximately 2-10 SCFH) should expel out the chamber needle valve. FIGURE 7 MOISTURE INDICATOR 19

TROUBLESHOOTING Table 1 Troubleshooting Guide for CPAD Series Heatless Regenerative Dryers Symptoms Cause Remedy A. Elevated Dewpoint. 1. Low purge flow. B. High back pressure on regenerating tower. NOTE: The tower should be at 0 PSIG during regeneration cycle. Any back pressure will result in improper regeneration. 2. Low inlet pressure. 3. Excess moisture carryover. 4. High inlet temperature. 5. Excess air/gas inlet flow. 6. Desiccant coated with oil. 7. Regeneration temperature low. 8. Dewpoint monitor out of calibration. 1. Muffler plugged. 2. Check valves leaking. NOTE: To test for leaking check valves during regeneration cycle, shut the purge adjusting valve. If gas is still passing through, it is an indication of leaking check valves. 1. Reset purge pressure at the recommended pressure. 2. Recalculate purge pressure setting from the chart. 3. Check prefilter element. Check drains at prefilter and afterfilter. 4. Check aftercooler operation. 5. Check total output of compressors. 6. Depressurize dryer and inspect desiccant. 7. *See B. 8. Recalibrate probe. 1. Replace mufflers. 2. Repair or replace faulty check valves. 3. Excess purge flow. 4. Restricted purge exhaust piping. 5. Too high purge. C. Excessive flow through mufflers. 1. Check valves leaking. NOTE: To test for leaking, check valves during regeneration cycle, shut the purge adjusting valve. If gas is still passing through, it is an indication of leaking check valves. 2. Inlet valves did not switch. 3. Purge valve stays open. 4. Repressurizing valve does not close. 3. Check and reset the purge pressure. 4. Remove obstruction or replace with larger size pipe. 5. Check purge calibration, plot and reset. 1. Repair or replace faulty check valves. 2. See E1 to E4. 3. Check purge solenoid and valve. Repair or replace faulty purge valve or solenoid. 4. Check repressurizing solenoid and valve. Repair or replace faulty repressurizing valve or solenoid. 20

Table 1 Troubleshooting Guide for CPAD Series Heatless Regenerative Dryers, continued Symptoms Cause Remedy D. No gas flow through the dryer. 1. Both inlet valves closed due to low inlet pressure. 1. Manually open the inlet valve by turning the shaft or the ON E. Failure to switch alarm light. 1. Inlet valves did not switch. 2. Faulty timer. 3. Insufficient pilot air pressure. 4. Cylinder leaking or seized up. F. High pressure drop in dryer. 1. Desiccant retainer screens plugged. 2. Excess flow. 3. High purge flow. 4. Purge valve stays open. 5. Repressurizing valve stays open. G. Dryer fails to purge. 1. Orifice plate plugged. 2. Purge valve fails to open. 3. Purge valve closed. 4. Purge check valve blocked. actuator. 1. Check pilot air solenoid valve. Repair if necessary. 2. Replace timer. 3. Clean or replace pilot filter element. 4. Repair or replace pilot air cylinder. 1. Replace desiccant retainer screens. 2. Check inlet flow conditions. 3. Check and reset purge pressure. 4. Check repressurizing solenoid valve, repair or replace if necessary. Check timer. 5. See C4. 1. Clean the orifice plate. 2. See F3. 3. Reset proper purge pressure. 4. Inspect purge check valve. Replace if necessary. H. High dewpoint alarm light. See chart on alarm conditions. I. Moisture indicator color turned translucent (wet conditions). 1. Bleed valve closed. 2. See probable cause on #1. J. Tower fails to pressurize. 1. Purge valve stays open. 2. Repressurizing valve faulty. K. Tower does not pressurize fully. 1. Inlet pressure low. 2. Purge pressure too low. 3. Repressurizing period too short. L. Excess desiccant dust. NOTE: If the regenerating tower does not pressurize fully, desiccant attrition takes place at the time of tower switchover. 1. See J & K. 2. Excess flow due to greater demand in process or addition of extra compressors. 1. Open the bleed valve to allow small amount of air to constantly flow through the gel. 1. See F3. 2. See C4. 1. Calibrate and plot purge pressure and reset. 2. Reset proper purge pressure. 3. Check timer sequence of operation. 2. Check outlet flow. 21

Table 2 Troubleshooting Guide for CPADM Mini Series Heatless Regenerative Dryers Symptoms Cause Remedy A. Elevated Dewpoint 1. Low inlet pressure. 1. Increase pressure (minimum 75 PSIG), or reduce flow. 2. Excess moisture carryover. 2. Check drains at aftercooler and prefilter. 3. Excess gas inlet flow. 3. Check the total output of compressors. 4. Desiccant coated with oil. 4. Depressurize the dryer and replace the desiccant. 5. Low inlet air temperature. 5. Raise inlet temperature above 75 F (24 C). B. High back pressure on regenerating tower. 1. Muffler plugged. 2. Shuttle valve leaking. NOTE: The tower should be at 0 PSIG during regeneration cycle. Any back pressure will result in improper regeneration. C. Excessive flow through mufflers. 1. Check valves sticking. 2. Purge valve sticking. 3. Timer short-circuited. D. Failure to switch. 1. Inlet valves did not switch. 2. Timer short-circuited. E. High pressure drop in dryer. 1. Desiccant retainer screens plugged. 2. High purge flow. 3. Purge valve stays open. F. Dryer fails to purge. 1. Orifice plate plugged. 2. Purge valve stuck closed. 1. Replace mufflers. 2. Clean, repair or replace faulty valve. 1. Clean, repair or replace valve. 2. Clean, repair or replace valve. 3. Replace faulty timer. 1. Clean, repair or replace valve. 2. Replace faulty timer. 1. Replace desiccant retainer screens. 2. See. C1 to C3. 3. Clean, repair or replace valve. 1. Clean the orifice plate. 2. Clean, repair or replace valve. 22

CP Compressors 1800 Overview Drive Rock Hill, SC 29730 Phone: 877-861-2722 Fax: 803-817-7468 www.cpcompressors.com