Installation Instructions. Remanufactured Veeder-Root Overfill Alarm and. Acknowledgement Switch. Overfill Alarm PMP # OEM #

Similar documents
Installation Instructions. Remanufactured Veeder-Root Sump Sensor. PMP # 62208, Replaces Veeder-Root # , -209

Installation Instructions. Remanufactured Veeder-Root Position Sensitive Sump Sensor. PMP # Replaces Veeder-Root #

Remanufactured Veeder-Root Discriminating Dispenser Pan and Containment Sump Sensors

Installation Instructions. Remanufactured Veeder-Root Steel Tank Interstitial Sensor. PMP # 62420, Replaces Veeder-Root # , -460

Manual No: Revision: C. Overfill Alarm. Installation Guide

Single-Point Mini Hydrostatic Sensor for Double-Wall Sumps

Manual No: Revision: D. Mag Sump Sensor. Installation Guide

Manual No: Revision: D. Sump Sensor. Installation Guide

Manual No: Revision: E. Groundwater Sensor. Installation Guide

Manual No: Revision: J. Groundwater Sensor. Installation Guide

Interstitial Liquid Sensor - Fiberglass Tanks

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

ONTIME TIMER SPECIFICATION

Owner s Manual. Model AC375C Refrigerant Recovery, Recycle, and Recharge Unit

36" GLASS SEALED-BURNER GAS COOKTOP

PLL. Pump-Lead-Lag. Provides Pump Rotation, Auxiliary Pump Activation, and Pump Failure Alarm Control. Installation and Operation Manual

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

TS-RA1, TS-RA2 and TS-RK Tank Overfill Alarms

Safety, Installation, and Operation Manual

Instruction Manual. Bucket Oil Pump

SAVE THESE INSTRUCTIONS

Application Note on Reading the Vigilohm IM400 Insulation Monitoring Device Installed in Conext Core XC and XC-NA Series Inverters

Refrigerant Recovery Machine. Model No Operating Manual

K00364 Electronic Bin Thermostat

Heliport Perimeter Light Type MIJ

Remote Relay Module (RRM)

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

TLS-300 UST Monitoring and Leak Detection System

PLL Pump-Lead-Lag. Provides Pump Rotation, Auxiliary Pump Activation, and Pump Failure Alarm Control. Installation and Operation Manual

Installation, Operation & Service Manual

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

GasScanner 4C. Four Channel Monitor. Operator s Manual. MINT-0280-XX Rev. A 02/25/08

2 To 1 Sensor Input Box

Instruction Leaflet. Read instructions before operating. Retain for future reference.

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

Instruction Leaflet. Read instructions before operating. Retain for future reference.

Series: MBC1-TC Mini Benchtop Temperature Controller

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

Instruction Manual. Dogeroo, Super Dogeroo, and Mini Dogeroo

USER MANUAL SAVE THESE INSTRUCTIONS

Manual No: Revision: H. MicroSensor. Installation Guide

SSF1610B-CN TRUSTED FOR OVER 100 YEARS. 16 inch (40cm) Oscillating. Stand Fan. Instruction Leaflet PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS

CENTERLINE 2100 Motor Control Center (MCC) Doors and Units with Vertical Operating Handles

Beacon 800 Gas Monitor Operator s Manual

Model 8780 INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS. Tempering Skid General Area Classification & Class I Division 2. No.

Model 9001EXP Alarm. NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

FLCH4R Garage and Utility Electric Heater

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

Operating Manual. Gasgard 100 Control System. Order No.: /00. MSAsafety.com

La Crosse Technology WT-8002U. Digital Clock with Indoor Temperature

Installation and Operation Manual

SUTTON 52 CEILING FAN

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

Controllers. Instruction Manual WARNING

ELSTON 52 CEILING FAN

Carbon Monoxide (CO) Detecting Ventilation Fan Controller Model COSTAR 24VC-e Single Relay

CurrentGuard TM. Installation, Operation and Maintenance Manual. CurrentGuardTM. Flush Mount. Surge Protective Devices A00

Owner s Manual & Safety Instructions

Instruction Leaflet. Read instructions before operating. Retain for future reference.

ELECTRIC FIREPLACE OWNER S MANUAL

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

TOUCHDOWN 48 CEILING FAN

ATA11U03. Non-Programmable Heat Pump Thermostat. Installation Manual. 97B0082N06 Revised: 16 September, 2013 FOR INSTALLER AND OWNER ONLY

PWW Drinkwell 2 Gallon Pet Fountain

Carbon Monoxide (CO) Detecting Ventilation Fan Controller Model 120VC Single Relay (100/25 PPM) (200/35 PPM)

USER'S INFORMATION MANUAL

Instruction Manual. Nacho Cheese Dispenser and Warmer

Always keep this manual in a safe readily accessible location. MODEL SERIAL SERVICE COMPANY TELEPHONE NUMBER

FAN POWERED VAV TERMINALS

INSTALLATION MANUAL CT-200

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

Installation Manual February Opticom Infrared System. Model 575 Confirmation Light Kit

ASG EZ-9000GR Tape Dispenser User Manual ASG #66136

be liable for any other loss or damage, whether direct, indirect, incidental or consequential.

SYSTEM CONTROL KIT Model: CK-41P

CPS-1 USER S MANUAL AIR INLET / CURTAIN CONTROL

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

INSTALLER S & OWNER S MANUAL

CabLite Luminous Auto Light Control Installation Manual

DUST FREE CARBON Whole House Air Purifier

BOLT ION 2-IN-1 CORDLESS VACUUM USER GUIDE REMANUFACTURED 1312R. For How-To videos, go to

Hot Dog Roller Grills

Installation Instructions

FAN POWERED VAV TERMINALS

Wrap-Around TOTE Tank / IBC Heaters (TOTE and TOT Series)

Analog Room Pressure Monitor RPC Series

TECHNICAL DATA OBSOLETE

Greentrol Automation, Inc.

Instruction Manual. Cheddar Easy All-In-One Cheese Corn Shop

Variable Speed Flow Controller

Ultrasonic Wall Switch Occupancy Sensor Single Circuit

OPERATION & INSTALLATION MANUAL

Model 9001, Alarm

Model 405 AIRGARD Fume Hood Monitor

ST. KITTS CEILING FAN

Steam Humidifier Fan Pack Installation & Maintenance Instructions

INSTALLER S & OWNER S MANUAL

AquiTron. AT-LDM Liquid Detection Module INSTALLATION INSTRUCTIONS

Transcription:

Manual Number: 01-62-768 Revision : 1.2 Date: 03/20/17 Installation Instructions Remanufactured Veeder-Root Overfill Alarm and Acknowledgement Switch Overfill Alarm PMP # 62625 OEM # 790091-001 Acknowledgement Switch PMP #62626 OEM #790095-001

Contents Disclaimer... 2 Related Manuals... 3 Safety Symbols... 3 BEFORE YOU BEGIN... 4 SAFETY PRECAUTIONS FOR INSTALLATION AND MAINTENANCE... 4 Description... 5 Compatibility... 5 Alarm Components... 5 Wiring the Overfill with an Acknowledgement Switch... 6 Wiring the Overfill without an Acknowledgement Switch... 7 Adjusting the Overfill Alarm Horn Volume... 8 Adjusting the Overfill Alarm Timer Cycle... 8 Testing the Overfill Alarm with the Acknowledgment Switch... 8 Programming the Console... 9 Testing the Overfill Alarm with the Console (and Periodic Testing)... 9 Overfill Alarm without the Acknowledgement Switch... 9 Overfill Alarm with the Acknowledgement Swith... 9 Disclaimer All product or company s names, trade names, trademarks, parts numbers and part descriptions may be the trademarks of their respective owners, and are used for reference or identification purposes only. PMP does not claim any right to or affiliation with such owners. The PMP product described here is remanufactured and sold by PMP and is not the product of any other identified manufacturer. 2

Related Manuals This installation requires specific knowledge of Veeder-Root equipment and you may need to refer to the following OEM manuals to complete the installation: 576013-589 Overfill Alarm Installation Guide 576013-623 TLS-3XX Series Console System Setup Manual 576013-879 TLS-3XX Series Console Site Prep and Installation Manual 577013-879 TLS-4XX Series Console Site Prep and Installation Manual 576013-818 TLS-3XX Series Consoles Troubleshooting Guide Safety Symbols The following safety symbols are used to alert you to potential hazards and precautions that should be taken. These symbols are not intended to alert you to all of the potential hazards you could be exposed to while working in a service station environment. These symbols cannot replace common sense and industry practices. Read and understand all of the written material related to the installation of this product. If you are un-sure of any aspect of this product, contact PMP for clarification Attention. Pay particular attention to the text adjacent to the use of this symbol to alert you to safety or operational issues. Remove / disconnect all power before proceeding with this installation. Potential shock hazard. Test circuit to verify power has been disconnected Cordon off work area with barriers to avoid contact with traffic Use appropriate safety equipment including equipment that may be mandated by federal, state and local regulations 3

BEFORE YOU BEGIN Service station equipment has both electricity and hazardous, flammable and potentially explosive liquid. Failure to follow the precautions below and instructions in this guide may result in serious injury and death. Follow all rules, codes and laws that apply in your area. Veeder-Root requires training certifications for contractors who install and set up equipment related to the TLS-350. Installers of this product must have a Veeder-Root certification of Level 2/3. Be sure that you have familiarized yourself with these requirements and determined if you are qualified to perform this installation. PMP shall not be liable for errors contained herein or for incidental or consequential damages in connection with furnishing, performance or use of this publication. PMP reserves the right to change product features or the information contained in this publication. Failure to install this product in accordance with OEM instructions and warnings will result in voiding of all warranties connected with this product and may damage the environment. SAFETY PRECAUTIONS FOR INSTALLATION AND MAINTENANCE Only a person with knowledge and experience with service station equipment should perform this work. Always make sure ALL power to the equipment you are working with is turned OFF before starting any maintenance. Note that more than one disconnect switch may be required to de-energize the equipment for maintenance and servicing. Use a voltmeter to make sure ALL circuits in the dispenser are deenergized. Failure to do so may result in serious injury. 4

Description Thank you for purchasing PMP Corporation s Overfill Alarm (#62625) and / or the optional Acknowledgement Switch (#62626). When used in conjunction with your tank gauge, the Overfill Alarm provides an exterior alarm to alert the driver of a high product or overfill condition during bulk delivery. The optional Acknowledgement Switch provides a method for the driver or station operator to acknowledge the alarm by pressing the Reset button without needing access to the tank gauge to silence the alarm. The Acknowledged light will remain lit until the tank gauge has printed an inventory increase report. The Acknowledgement Switch also provides a convenient Test button to allow periodic testing. Depending on your tank gauge and / or site configuration, additional hardware may be required. For example, if connecting the Overfill Alarm to a TLS-350, an Input /Output Combination module or 4 Relay Output module may be required. Be sure to read and understand your tank gauge documentation prior to beginning the installation process. Compatibility Console Series TLS-450 8600 TLS-350R* 8482 TLS-350* 8470 TLS-300 8485 TLS-250 7841 TLS-250i 7941 *An Input/Output Combination Module (329299-00x) or 4-Relay Output Module (329359-00x) Module is required. Verify your system is properly equipped before starting the installation. Alarm Components PMP Number OEM Number Description 62625 790091-001 Overfill Alarm 62626 790095-001 Alarm Acknowledgement Switch Mount the Overfill Alarm and Acknowledgement Switch 1. Turn-off power to the system. 2. Block off the work area. 3. Check your local building codes to be sure there are no requirements for where the Overfill Alarm and Acknowledgement Switch are mounted. 4. Depending on where you choose to mount the Overfill Alarm and Acknowledgement Switch, firmly mount using the 4 holes on the mounting tabs provided on each box (hardware not included). 5

Wiring the Overfill with an Acknowledgement Switch Wire used for this installation must have a rating of at least 90 C, must be 14 or 16 AWG and be color coded. Use the color illustration below as guide. However, the colors used are for clarity. The actual wire colors you use may be dictated by national and local codes. 1. Install one wire between terminal 1 of the Overfill Alarm to terminal 2 of the Acknowledgement Switch. 2. Install one wire between terminal 2 of the Overfill Alarm to terminal 3 of the Acknowledgement Switch. 3. Install one wire between 120 vac neutral to terminal 4 of the Acknowledgement Switch. 4. Install one wire between 120 vac line to terminal 5 of the Acknowledgement Switch 5. Install one wire between terminal 5 of the Acknowledgement Switch to Common terminal of the console relay output. 6. Install one wire between terminal 1 of the Acknowledgement Switch to the Normally Open terminal of the console relay output. 120 vac Terminal Block Position TLS Relay Output Overfill Alarm Acknowledgement Switch Normally Open Common 1 1 2 2 3 Neutral 4 Line 5 6

Wiring the Overfill without an Acknowledgement Switch Wire used for this installation must have a rating of at least 90 C, must be 14 or 16 AWG and be color coded. Use the color illustration below as guide. However, the colors used are for clarity. The actual wire colors you use may be dictated by national and local codes. 1. Connect one wire between 120 vac Neutral to terminal 1 of the Overfill Alarm. 2. Connect one wire between 120 vac Line to common terminal of the console relay output. 3. Connect one wire between the Normally Open terminal of the console relay output to terminal 2 of the Overfill Alarm Terminal Block Position TLS Relay Output Overfill Alarm Normally Open Common 120 vac Neutral Line 2 1 7

Adjusting the Overfill Alarm Horn Volume 1. The adjustment screw is on the front of the horn body. 2. Locate the screw where shown. 3. Using a 1/16 hex key, turn the screw counterclockwise to make the horn louder. Turn the screw clockwise to make the horn quieter. Adjusting the Overfill Alarm Timer Cycle 1. Loosen the 4 screws which hold the Overfill Alarm door closed. 2. Slide the brackets out of the way and open the door. 3. Locate the timer module located inside the Overfill Alarm. 4. You can adjust the time will remain on between 0 60 seconds. Adjust the time by turning the knob to the desired setting. Clockwise to increase the time, counterclockwise to decrease the time. 5. When finished, close the door and retighten the brackets and cover screws. Testing the Overfill Alarm with the Acknowledgment Switch 1. If you have chosen to install the optional Acknowledgement Switch, ensure the power is on to the Overfill Alarm and the Acknowledgement Switch 2. Press and hold the TEST button located on the side of the Acknowledgement Switch. 3. The Overfill Alarm will sound and the red beacon will start flashing. 4. If you continue to hold the TEST button, the horn will turn off at the pre-determined time set above. 5. The red beacon will continue to flash until the TEST button is released. Test Button 8

Programming the Console 1. Consult your console manuals on how to properly program the console to assign the Overfill Alarm to the desired relay output along with programming the set points at which the alarm will be activated. 2. The following is a high-level view of the programming steps necessary for a TLS-350 / TLS-300 console: Testing the Overfill Alarm with the Console (and Periodic Testing) 1. After you have installed the Overfill Alarm and the Acknowledgement Switch (if installed), turn power Off to the console and the Overfill Alarm / Acknowledgement Switch. 2. Install a jumper wire between the two relay contacts being used for the Overfill Alarm. For example: Overfill Alarm without the Acknowledgement Switch 1. Restore power to the console and Overfill Alarm. The alarm will sound immediately after power is restored. The beacon should also begin flashing. 2. Turn off power to the console and Overfill Alarm. Remove the jumper wire between the relay contacts. 3. Restore power to the console and Overfill Alarm. Overfill Alarm with the Acknowledgement Swith 1. Restore power to the console and Overfill Alarm. The alarm will sound immediately after power is restored. The beacon should also begin flashing. 2. Press the RESET button on the front of the Acknowledgement Switch. The alarm horn and the flashing beacon should turn off. However, the ACKNOWLEDGED light on the front of the Acknowledgement Switch should turn on. The light will remain on until the cause of the alarm has been addressed. 3. Turn off power to the console and Overfill Alarm. Remove the jumper wire between the relay contacts. 9

All product or company s names, trade names, trademarks, parts numbers and part descriptions may be the trademarks of their respective owners, and are used for reference or identification purposes only. PMP does not claim any right to or affiliation with such owners. The PMP product described here is manufactured or remanufactured and sold by PMP and is not the product of any other identified manufacturer. 10