Thank you for choosing EnviroVent

Similar documents
November This product has been reconfigured Please read these instructions

MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER

01 Safety. IMPORTANT Be sure to have read and understood these instructions before beginning the installation process.

Wiring the fan correctly...

Thank you for choosing EnviroVent

HOTLINE:

Watch the heatsava video

Wiring the fan correctly...

energisava 200 WALL & FLOOR MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER

230V & SELV INSTALLATION GUIDE FOR ENGINEER / INSTALLER IPX4 IPX5

Thank you for choosing EnviroVent

HOTLINE:

energisava 200 CEILING MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER

ECo 2 Wall USER GUIDE FOR RESIDENT

ECo 2 Wall INSTALLATION GUIDE FOR ENGINEER / INSTALLER

PIV & MIV Loft Mounted Unit INSTALLATION GUIDE FOR ENGINEER / INSTALLER

Introducing the RetroVent

KUDOS. Instruction leaflet

Slimline 150 & 300 Exceptionally low energy consumption. High Efficiency, Low Profile Heat Recovery Range

Lo-Carbon SELV Tempra

Filterless Infinity Designed to Perform. Built to Last. WC, Bathroom & Kitchen

CLASSIC-100. Instruction leaflet. Instruction leaflet

airooncentre.co.uk irconcentre.co.uk Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Quick Order Hotline or

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

fact fact fact result No quibble, 7 year warranty. No strings attached. No fans going to landfill sites Happy tenants Money saved

energisava 300 & 400 Constant flow technology High Efficiency Whole House Heat Recovery Systems

energisava 200 High performance in a compact unit High Efficiency Whole House Heat Recovery System

Filterless Extract Fan. WC, Bathroom + Kitchen

GUH90 90 cm Canopy Hood

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

Stainless Steel Chimney Extractor

Centrif Duo & Centrif Duo Plus

60cm Chimney Extractor

GUH52SD 52 cm GUH75 75 cm Canopy Hood

Stainless Steel Chimney Extractor

I n s t r u c t i o n m a n u a l f o r b u i l t - i n h o o d. Model code: BORA600

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS.

Model: Kair Whole House Ventilator Model Number: KHRVWH2000

60cm Integrated Turbo Extractor

ECO dmev Decentralised MEV

Lo-Carbon Quadra Centrifugal Fan

FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans

isense & isense-ht 230V Flush Mounted Domestic Continuous Extract Fans

Installation and Maintenance

BWT6.3GL Cooker Hood 60 cm Glass chimney hood

BT16.4SS-HK BT19.4SS-HK Cooker Hood

I tho Advance. Heat recovery ventilation unit. User manual A6_ Ventilator Advance ENGELS.indd /0111/ED

Stainless Steel T-Box Extractor

MODEL: DV72 R & L. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual

Cyclone 7 Designed to Perform. Built to Last. WC. Bathroom & Kitchen

BFR6 / BFR9 Rangehood

Lo-Carbon Quadra SELV

Internal/External Wall/Window Fan Range GX6. Installation and maintenance instructions Retain for future use

Simply Silent Contour 4 (100mm) Axial Extraction Fan

UBGHFF60W 60cm Gas on Glass Gas Hob

BWTC6510GL Cooker Hood 60 cm Glass cooker hood in stainless steel. BWTC9510GL Cooker Hood 90 cm Glass cooker hood in stainless steel

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside

Electronically controlled instantaneous water heater. MCX: 27300, and models. Installation instructions

Installation and Maintenance Instructions for the Installer. Please refer to the User Manual for instructions on how to operate the system

Lucci Designer Hi Flow Exhaust Fan

ECOLEC PANEL HEATERS GENERAL NOTES.

90cm Chimney Extractor

Xpelair Simply Silent TM Contour Fan

MRXBOX95B-LOFT. Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Loft Mounting. Installation and Maintenance

Xpelair Simply Silent DX150

BLOW DRY & GO HAIR KIT

Stainless Steel and Glass Angled Extractor

condensation mould high humidity

Installation & Operating Instructions

INSTRUCTIONS AND WARRANTY

IXL Eco Ventflo. User Guide. Model: (200mm) - Extraction Rate: 340m 3 /h Model: (250mm) - Extraction Rate: 490m 3 /h

IF IN DOUBT, INSTALLATION SHOULD BE MADE BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH CURRENT WIRING REGULATIONS.

Warnings, Safety Information and Guidance

Island Extractor. Instructions & Installation LAM

WHHR Midi & Midi Lite

Installation and Maintenance

INSTRUCTIONS AND WARRANTY

GEH9026G Cooker Hood

ELIX 1003 IPX4. Energy Efficient Centrifugal Fan with EC Motor Installation and Operating Instructions

INSTRUCTIONS FOR USE

Centair CMEV.4 / CMEV.4e / CMEV.4eHT Mechanical Extract Ventilation (MEV) System Installation Instructions

Installation and Maintenance

ELEGANCE IPX4 IPX7. Low Carbon Fan with EC Motor Installation and Operating Instructions. 6 models:

ZIP InLine. Models: ES3, ES4 & ES6. Electronic Instantaneous Water Heaters. ES3, ES4 & ES6 Instructions. V1.09 Page 1 November / 2015

Xpelair Simply Silent TM DX100 Fan

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS IMPORTANT: READ AND SAVE THESE INSTRUCTIONS FOR THE BENEFIT OF THE USER

Compact Cyclonic Bagless Upright Vacuum Cleaner

Installation and Maintenance

User Manual for your GEH6017 & GEH9017 Cooker Hood

Personal Blender User guide

Installation and Maintenance

Purge Ventilation Unit. Product Manual. ventilation systems TP625

Saletto. Operating Instructions. Low Profile Panel Heaters Models: LPP050 LPP075 LPP100 LPP150. A world of expertise

Double Door - Dual Zone Wine Cooler

Girona. Operating Instructions. Glass Panel Heaters. Models: GFP050 W/B GFP075 W/B GFP100 W/B GFP150 W/B GFP200 W/B. A world of expertise

CMX-S. Company name: Contact: Tel: Central Mechanical Extract Ventilation (cmev) appliance. Installation and Operating Instructions

Xpelair Simply Silent DX100B

INSTALLATION & USER INSTRUCTIONS

Baxi Combi 133 HE Plus Baxi Combi 100 HE Plus Baxi Combi 80 HE Plus. User s Operating Instructions

Turbo Cyclonic Pro Bagless Cylinder Vacuum Cleaner

Transcription:

Contents 01 Introduction 2 02 Technical Specification 3-4 03 Wiring Diagrams 5-6 04 Safety 7-8 05 Controls 8 06 Box Contents 9 07 Tools Checklist 10 08 Installation Steps 11 09 Installation 12-22 10 RF Controller (Optional) 23 11 Cleaning & Maintenance 24-26 12 Guarantee 27 01 Introduction Designed for through the wall installation, the heatsava is ideal for both refurbishment and new build properties. The outside diameter of the heat exchange casing is smaller than a standard wall sleeve and can therefore utilize an existing one already in place. The heatsava also takes into account the complexities of different wall depths to offer 4 different main lengths that the heat exchange casing is manufactured to (see page 4). The unit is installed from the inside out to allow for ease of installation in highrise applications. The heatsava is exceptionally versatile and can be installed horizontally or vertically in 4 different positions through 360. The unit has been designed to operate continuously. Thank you for choosing EnviroVent The fastest growing ventilation company in the UK Ensure that this product is treated with care, installed and maintained correctly i.e. for the life of the building. Remember, if you have any problems please call our dedicated Technical Team. 2 SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL

02 Technical Specifications Unit Dimensions Rear Assembly (Extract Fan) Centre Assembly (Electronics) Front Cover Cowl End Heat Cell Fan Adaptor Assembly (Supply Fan) AFTER INSTALLING THIS UNIT PLEASE PASS ONTO END USER DO NOT THROW AWAY 3

02 Technical Specifications Heat Cells Options Wall Depth mm (A) Cell Order Size mm (B) 100-330 330 331-430 430 431-500 500 501-600 600 Ø150 Ø100 4 SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL

03 Wiring Diagrams - Mains NOTE: This unit is supplied as a mains version (option 1). See next page for SELV (option 2). Connect 2 core cable into existing wiring NOTE: Discard SELV box if installing mains version (option 1) Fan Board Power Supply AFTER INSTALLING THIS UNIT PLEASE PASS ONTO END USER DO NOT THROW AWAY 5

03 Wiring Diagrams - SELV SELV (option 2). SELV box and lid Fan Board Mains Remove power supply from the unit Place in SELV box SELV Box must be secured using the 4 fixing points Power Supply Use tags to restrain cable 12v Make electrical connections as shown Secure the lid with screw. 6 SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL

04 Safety Be sure to have read and understood these instructions before beginning the installation process. All wiring must comply with Building Regulations and the current I.E.E. Wiring Regulations (BS7671) or the equivalent standards for your country. The final installation should be examined and tested by a qualified electrician. Make sure the mains supply complies with the rating label for voltage, frequency and phase. IPX4 Rated This unit has been tested to IPX4 and is suitable for installation within Zone 1 of bathrooms. However, we recommend that you must not position the unit near any water devices such as taps, shower heads or jets and ensure water is not aimed directly at the unit. Do not use jets or shower heads etc to clean this unit. Never modify the fan or electronics. Do not store inflammable products in the vicinity of this product. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. For a bathroom application the power supply should be installed outside the bathroom as it is 230V. IMPORTANT: This unit draws air in from atmosphere and you must ensure that any emissions from any other systems such as gas or oil boilers, do not contaminate the air entering the heatsava product. Therefore, before installation, consider where the external cowl will be located in relation to any boiler flues etc. Externally, you must ensure that the unit is positioned a minimum distance away of; 1 metre horizontally, 1 metre below or 3 metres above any boiler flue etc. In kitchens, if the unit has to be fitted above a cooker, it must be installed a minimum distance of 650mm above electric cookers and 750mm above gas cookers, and not have a pullcord fitted. AFTER INSTALLING THIS UNIT PLEASE PASS ONTO END USER DO NOT THROW AWAY 7

04 Safety Electrical Assembly When wiring the unit in, a suitable disconnect device such as a fused spur should be used, do not use a plug. The means of disconnecting the unit from the mains power supply must be incorporated in the fixed wiring in accordance with the wiring rules. There must be a necessity to allow disconnection of the appliance from the supply after installation, unless the appliance incorporates a switch complying with the wiring regulations The disconnection may be achieved by incorporating a switch in the fixed wiring in accordance with the wiring regulations. The electrical install comprises of a power supply unit or a low voltage box - SELV. See pages 5-6 for wiring diagrams. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. 05 Controls Pullcord (Manual) The heatsava comes complete with a pull cord to activate the boost if required. Pull once to activate the boost and once to deactivate. Summer Mode (Automatic) During warmer days, the heatsava prevents warm air from entering the room and switches to provide extract ventilation only. As the temperature falls it automatically returns to heat recovery mode. Frost Protection (Automatic) Intelligent Humidity Tracking (Automatic) The heatsava has been engineered with intelligent controls to think for itself, meaning that you don t need to press any buttons or light switches to turn it on. When the heatsava senses a rise in humidity, caused by increased moisture generation such as through cooking or showering, the extract and supply airflows will slowly begin to increase in direct proportion to the increase in humidity. It will then automatically track back down again when humidity falls. This controls condensation quietly and efficiently. The heatsava has an automatic built-in frost protection mechanism to prevent any damage to the heat exchange cell in cold conditions. 8 SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL

06 Box Contents Description Quantity Item heatsava Unit 1x Heat Cell 1x Instructions Guide 1x SELV Box 1x Halo (Wall Kit Contents) 1x Wall Seal 1x Fixing Template 1x Fixing Kit 1x 8G X 2.0 - (Fixing Kit Contents) 10x Red Wall Plugs - (Fixing Kit Contents) 10x Terminal Block (Spare) 1x AFTER INSTALLING THIS UNIT PLEASE PASS ONTO END USER DO NOT THROW AWAY 9

07 Tools Checklist (Not supplied) Description Item Core Drill Electric Screwdriver Long & Short Screwdriver Small Terminal Screwdriver Spirit Level Cutting Pliers Long Nose Pliers Ladder Solvent Cement Silicone 10 SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL

08 Installation Steps Step Instruction Page Number 1 Read Instructions 12 2 Boiler flue exclusion zone 12 3 Use the template to position and orientate the unit 12 4 Check unit size & wall depth 13 5 Clearance from walls and ceilings 14 6 Heat cell cowl orientation 15 7 Use marking template 16 8 Drill fixing holes 16 9 Drill core hole 16 10 Wall sleeve 17 11 Rubber wall seal 18 12 Fit pull cord to suit orientation 20 13 Fix unit to wall 21 14 Make electrical connection 21 15 Check unit is working 21 16 Fit halo to outside if required 22 17 Wireless control (optional) 23 18 Inform building owner/user on how to operate the system 19 Give instructions to end user These checks are required to ensure the proper function of this unit. For EnviroVent Technical help call 0345 27 27 810 AFTER INSTALLING THIS UNIT PLEASE PASS ONTO END USER DO NOT THROW AWAY 11

09 Installation IMPORTANT: This unit draws air in from atmosphere and you must ensure that any emissions from any other systems such as gas or oil boilers, do not contaminate the air entering the heatsava product. Therefore, before installation, consider where the external cowl will be located in relation to any boiler flues etc. Externally, you must ensure that the unit is positioned a minimum distance away of; 1 metre horizontally, 1 metre below or 3 metres above any boiler flue etc. In kitchens, if the unit has to be fitted above a cooker, it must be installed a minimum distance of 650mm above electric cookers and 750mm above gas cookers, and not have a pullcord fitted. Read instructions 2 4 Cell? 3 1 12 SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL

09 Installation Select Unit Ø150 Ø100 Wall Depth mm (A) Cell Order Size mm (B) 100-330 330 331-430 430 431-500 500 501-600 600 AFTER INSTALLING THIS UNIT PLEASE PASS ONTO END USER DO NOT THROW AWAY 13

09 Installation Clearance - Walls The heatsava has been designed to allow easy installation into an existing wall sleeve which is located near the ceiling. When core drilling into an existing wall, make sure you have enough space to move around and distance between the wall and any objects nearby i.e cupboards (Fig.5). heatsava LEAVE ADEQUATE CLEARANCE Ensure the unit is sited in a suitable position for adequate clearance on all sides for easy access to the unit for maintenance purposes and to ensure that access to the release clips on the front cover is not inhibited. cupboard Fig.5 Plan layout Ceiling 20mm min 20mm min Cover release clips Clearance - Ceilings First measure the wall depth. If installing into a new build application, we recommend that the unit should be installed in the position below (option 1). If installing into an existing wall sleeve which is located near to the ceiling, the heatsava can be installed horizontally or vertically (options 2-4). Option 1 Option 2 Ceiling 30mm min 30mm min Option 3 Option 4 Pullcord positions shown. Pullcord NOT supplied with wireless version of product. 14 SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL

09 Installation 12 Heat Cell - Cowl Orientation When fitting the heat cell into a wall, ensure that the cowl end is correctly orientated with the end always facing down. (Fig 4.) 9 Cell Cell 3 Cowl Fig.3 Fig.4 6 Solvent Cement (not supplied) X4 AFTER INSTALLING THIS UNIT PLEASE PASS ONTO END USER DO NOT THROW AWAY 15

09 Installation Select core drill size 100 107mm 117mm Wall Sleeve Wall Seal 150 158mm 162mm Wall Sleeve Wall Seal Template X3 Use either holes A or B 107, 117, 158, 162 16 SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL

09 Installation Wall Sleeve - Choose rubber wall seal or wall sleeve installation. Wall sleeve not supplied A 99mm (100) or 149mm (150) Ø overall B 100mm or 150mm Ø internal (min) C 107mm or 158mm Ø Use existing sleeve or insert new sleeve into wall. X X =X A B Wall sleeve C Cement =X Apply cement around sleeve and insert through wall. AFTER INSTALLING THIS UNIT PLEASE PASS ONTO END USER DO NOT THROW AWAY 17

09 Installation Rubber Wall Seal - Choose rubber wall seal or wall sleeve installation. 117mm or 162mm Ø =X =X 18 SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL

09 Installation Solvent Cement 117mm or 162mm Ø AFTER INSTALLING THIS UNIT PLEASE PASS ONTO END USER DO NOT THROW AWAY 19

09 Installation Pullcord - See page 14 for pullcord options. Option 3 & 4 Option 1 & 2 20 SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL

09 Installation X3, A or B Make electrical connection - See pages 5 and 6 AFTER INSTALLING THIS UNIT PLEASE PASS ONTO END USER DO NOT THROW AWAY 21

09 Installation External - Fit halo if required Silicone (not supplied) Installation Completed 22 SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL

10 RF Controller (Optional) To pair an additional RF controller 1. Turn the unit off at the isolation point. 2. Restore power; for 20 seconds from restart the unit will be in pairing mode. 3. Press the remote button once within the 20 seconds and the control will pair to the unit. 4. Successful pairing is indicated by a green light on the control. Press button once to show current function. Press button again within 3 seconds to move to next function (trickle & boost only). Other functions are automatic, each function has an indicator light, which operates once selected. AFTER INSTALLING THIS UNIT PLEASE PASS ONTO END USER DO NOT THROW AWAY 23

11 Cleaning & Maintenance Cleaning General cleaning of the vents and cells should be every 6 months max, or as required, as environments will vary. Service Maintenance Intervals General maintenance should ideally take place every 12 months and should be carried out only by a competent tradesperson adhering to the instructions. 5 Year Service The heat exchange cell and all components and parts should be inspected every 5 years. x2 Disconnect 2 clips and remove fan adaptor by using 4 screws 24 SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL

11 Cleaning & Maintenance AFTER INSTALLING THIS UNIT PLEASE PASS ONTO END USER DO NOT THROW AWAY 25

11 Cleaning & Maintenance Damp cloth Soft brush Vacuum 26 SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL

12 Guarantee The EnviroVent heatsava is covered by a full 5 year warranty which will benefit the occupier over many years. What should I do if I have a problem? If, after thoroughly reading this booklet, you feel that your heatsava is not working correctly, you can telephone 0345 27 27 810 (operational from 8:00am to 5:30pm Monday to Friday), and ask for technical assistance. You will either be given guidance over the telephone, or an arrangement will be made for an engineer to visit. In any event, please have the following information ready. This will enable your call to be dealt with quickly and efficiently. Please note that proof of purchase by the way of a receipt is required and that any fans bought from an unapproved source, including but not limited to online auction websites, will render the guarantee invalid. Serial number of the unit: 12 Warranty We appreciate you choosing this quality EnviroVent product, which is designed and manufactured to the highest specification in Harrogate, North Yorkshire. We are confident that you will be delighted with the performance of the system and the resulting improvement in air quality in your home after the installation of the unit. Your warranty covers any defect or break down that arises due to faulty materials or construction. WARRANTY CONDITIONS AND EXCLUSIONS The system must be correctly installed and operated according to the instructions contained in the user guide supplied. The warranty will be rendered invalid if the system has been serviced, maintained, repaired, taken apart or tampered with by any person not authorised by EnviroVent Ltd. The warranty will be rendered invalid if the unit is turned off. Turning the unit off can damage it. The warranty does not cover accidental damage, misuse or abuse. The warranty is in addition to your statutory or legal rights. The guarantee will only be honoured from approved suppliers. AFTER INSTALLING THIS UNIT PLEASE PASS ONTO END USER DO NOT THROW AWAY 27

EnviroVent Ltd EnviroVent House Hornbeam Business Park Harrogate HG2 8PA 01423 810 810 info@envirovent.com www.envirovent.com E&OE MKT ENV252-V15-28.03.17 Due to our policy of continuous innovation and improvement EnviroVent reserves the right to alter products specification and appearance without notice.