MultiMeter 44. Transmitter-regulator with 1, 2 or 3 channels. Quality at a reasonable price

Similar documents
Concise catalogue Water-Industry

Date SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1

Steam and Water Analysers

Corporate Profile. needs and product demands. CON 08X /03 Rev 0

SECTION Free/Available Chlorine Analysis System

Krypton K CL2. Measuring and control system for free chlorine. applications. description. Low maintenance by automatic sensor cleaning

K 100 (W) DES. Disinfectant measurement. Applications. Description. Intuitive and simple menu Safety by password function. Disinfection.

Chlorine / Chlorine Dioxide Measurement liquisys S CCM 223 / 253

High Pressure Conductivity Monitor

SECTION Fluorescent Dissolved Oxygen Measuring System

Inductive Conductivity

Dissolved Oxygen Measurement liquisys M COM 223 / 253

Measuring Recording Online Monitoring Regulation Alarming

ATSTORM v2. The sensor with FCES technology is connected to the interface with a communication cable.

HIGH CAPACITY PRODUCT LINE

Entwicklung + Fertigung + Service: Heerweg 15 D, Denkendorf Tel.: / Fax.: /

HIGH CAPACITY PRODUCT LINE

Inductive Conductivity Measurement. Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement symbol.

BC3250. Blowdown Controller

MEAS CAL ALARM WASH CONF APT4000 CC ENCLOSURE TYPE 2

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

CTT8 TEMPERATURE MONITOR DEVICE

MEAS CAL ALARM WASH CONF APT4000 TC

Toroidal Conductivity Transmitters Series APT4000 Specifications

MO n : 12JMC rév A

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

OPERATION MANUAL. THE JENCO MODEL 6230 MICROCOMPUTER BASED ph/mv/temp PORTABLE METER JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS

Stratos MS. Internationally recognizable icons provide operating information and draw attention to unusual operating states.

Dissolved Oxygen Measurement liquisys S COM 223 / 253

Dew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510

MEAS CAL ALARM CONF APT2000 CC ENCLOSURE TYPE 2

SCAN200E USER S MANUAL

Free Chlorine Measuring System

UDA2182 Universal Dual Analyzer

Instruction manual. Analyt 2 / Analyt 3

COBRIX3 multibev. Online Beverage Analyzer. ::: Unique Density & Concentration Meters

203RE ph v 1.0 Instructions

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals

Inductive. Range. S410/IND Electrodeless Conductivity Sensors

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

OPTISENS TUR 2000 Technical Datasheet

Gas Controller Module GC-06

Process & TeMPerATUre UniversAl input DigiTAl MeTers

Analyze IT Zirconia Oxygen Analyzer for Small Boiler Applications

UDA2182 Universal Dual Analyzer

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual

Personal ph, ph/orp, Conductivity Meters PH71/PH72/SC72

Process Alarm Module RTA 421

Dissolved Oxygen Analyzers

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

Controller Specification Sheet

1.7. Insulation fault evaluators EDS460/490 EDS461/491

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

Turbimax CUE21 / CUE22

MEAS CAL ALARM WASH CONF APT4000 PH ENCLOSURE TYPE 2. Description

RS485 MODBUS Module 8AI

Figure 1 DirectLine DL423 Sensor. Description, continued

I/A Series 716C 1/16 DIN Temperature Controller

SCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances

MEAS CAL ALARM WASH CONF APT4000 PH ENCLOSURE TYPE 2. Description

TEMON 4-C. Doc. N MO-0368-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 4-C OPERATION MANUAL. Microener- Copyright 2010 FW 2.1 Date Rev.

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

EC 6-295P220S001. smart guide 2 OPERATION. 2.1 How to turn the instrument ON/OFF. If you have to turn the instrument ON/OFF:

Multi-Gas-Controller MGC2

LC1350 Level Controller

Personal ph, ph/orp, Conductivity Meters

PREVENTIVE PROTECTION PROTECCIÓN PREVENTIVA

AquaLynx 200 ADX. Monitoring and Control System. Background. Operation

Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE

ZDT GP Series High Temperature Zirconia Oxygen Analyzer. Superior technology and quality from the world leader in oxygen measurement

Dew point set DS 400

Detection, Protection, Innovation

XWA11V. Walk-In Temp / Door /Alarm / Light Module

Hydrazine Analyzer Series 2171 Specifications

Personal ph, ph/orp, Conductivity Meters

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

Low Temperature Zirconia Oxygen Analyzer

Two-Channel Gas Controller

Model Q45P/R. ph/orp Monitor...

RVP310. Heating Controller. Building Technologies HVAC Products

eed quality electronic design USER s MANUAL

1 4 DIN Dissolved Oxygen Controller

ST Wiring diagram. Product description. Standard temperature controller. Order number

portable gas analyser

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. SIL1 reliability. Gas Detection Control Panel

SECTION INDUCTIVE CONDUCTIVITY ANALYZERS

PolyGard 2-channel Gas Controller MGC-03

Air & Water Heat Pump R832

Operating Instructions XWA11V XWA11V. Walk-In Temp / Door /Alarm / Light Module

RAYCHEM NGC-30 COMPONENTS

873A Series Electrochemical Analyzers ph, Contacting Conductivity, Electrodeless Conductivity, and Resistivity

PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207

Miniature Infrared Temperature Sensors with Optional Touch Screen Display. PSC-SSS-PM with touch screen display (-CRT version)

JENCO ELECTRONICS, LTD.

Transcription:

MultiMeter 44 Transmitter-regulator with 1, 2 or 3 channels MultiMeter 44 is a modular meter that can be configured with one, two or three channels. It can be delivered with only one measuring channel, with possibility for channel extension by the user. The three channels can measure the same parameter or three different parameters. The MultiMeter 44 is very easy to program and use. The customer does not need specific learnings. MM 44 is the best instrument for DO (dissolved oxygen) measurement in waste water. It is able to work with amperometric sensor and optical sensor based on the fluorescence principle. With this instrument CRISON consolidates to the high-performance instrumentation. MM 44 with the option PROFIBUS DP can be integrated in industrial communication net. Quality at a reasonable price

MultiMeter 44 Field or panel mounting instrument, configured with one, two or three measuring channels. Key features: Simultaneous visualization of all measured parameters. Security code prevents measurement interruption by unauthorized personnel. Only authorized personnel have an access to instrument programming and calibration. Direct calibration in ph, redox and conductivity, with automatic recognition of the standards and rejection criteria for sensors in poor conditions. One single temperature sensor can be used for the temperature compensation in the different channels. Alarm and sensor cleaning relays in the basic instrument. Moreover, two limit relays per each measuring channel. Two programmable analogical outputs per each measuring channel. For example, ph and temperature. Interface RS 232 as standard. Interface RS 485 (optional). PROFIBUS (optional). Software in 4 languages: Spanish, English, Italian and Catalan. Measurements presentation in standard format or in big format. Data Logger for 400 readings per channel. Description ph 7 Advantages: Up to three instruments in one. Instrument very easy to use thanks to the elaborated software. Indirect calibration, readjusting any value inside the measuring range, including the temperature without need to dismount the sensors. Display and keypad protected by a cover closing hermetically. Protection IP 65. Possibility for software updating in situ. Field or panel installation without distinction. 5 years guarantee for the instrument. Technical support directly from the factory. Very competitive price. Up to 3 channel extension by the user. Maximum security of measurement The instrument controls continuously the sensors. If the sensor s signal does not change during a defined period, an alarm is activated. The alarm activates if there is a sharp signal change too. On the graph, two examples of ph measurement are shown. ALARM t ph 7 ALARM t Long life keypad, Special for industrial use. Backlit display. Operating and assisting messages. ABS enclosure. IP 65 protection. Shock resistant. Transparent cover with easy opening. MP-5 connector. For Data Logger emptying. Cable glands. For cable entrance. 2 MultiMeter 44

MultiMeter 44 Two visualization modes Standard mode. Display of measurement Information display during calibration Information display in programming of one channel ph 7.15 25 C mv 612 OD 0.36 mg/l 25.2 C CALIBRATING mv Insert electrode in 220 mv buffer Start... 25 C C1 PROGRAMMING C1 Units Temperature Control with relays Alarm Output, ph Big display mode. Pressing the key the display changes into big display mode. The corresponding data to every measuring channel are appearing successively making possible the visualization from long distance. ph 7.15 1 25 CmV 615 2 Dimentions 215 mm 100 mm 55 mm 210 mm ESC * OK IP 65 Frontal view Side view Side view (panel) Installation Field Panel MultiMeter 44 3

MultiMeter 44. Diagrams blocks Basic instrument It is formed by the essential parts of the instrument and by the common parts for all channels such as RS outputs and relays for alarm and sensor cleaning. It is non-functional set that must be completed with measuring/regulating boards required by the user (1, 2 or 3). Alarm relay. This relay can be activated due to different reasons in accordance with the programming of every channel. The reason for alarm activation is shown on the display. Sensor cleaning relay. It is used for activation of an electrovalve or a pump which supplies air or liquid flow over the sensor installed in the corresponding housing. Communications. outputs. Incorporated in every measuring board. Interface RS 232. Included in all instruments independently of their configuration. Interface RS 485. This option must be ordered. It is used for communication of several instruments with a. PROFIBUS DP. This option must be ordered. It is used for the integration of the instrument in PROFIBUS system. 230 VCA RS 232 Basic instrument configuration 230 VCA RS 232 RS 485 Sensor s cleaning Alarm GSM Memory module Sensor s cleaning Alarm GSM Memory module Other instruments, MM 485 application Basic instrument configuration + RS 485 option Measuring-regulating boards Every measuring board includes two outputs, one for the measured parameter and the other for the temperature. The boards include two limits relays that can be programmed without distinction as minimum or maximum limits. Regulation ON / OFF: it is performed by programming suitably the relays that activate and deactivate with a delay. The hysteresis is programmable. Proportional: - Using the limit relays that activate during time proportional to the distance between the real reading and the optimal value. - Using the output, programming the value corresponding to the control start. 230 VCA RS 232 PROFIBUS DP Basic instrument configuration + PROFIBUS Sensor s cleaning Alarm GSM Memory module 44 10 Board for measurement of ph / redox and C The electrodes are connected directly to a terminal strip, no need of special connectors. The high impedance of the electrode is protected and warranted by the system Guard Ring. Redox calibration with standard 220 mv, indirect calibration or by introducing the data of an electrode calibrated previously. ph / mv + ph/mv ph/mv 4 MultiMeter 44

44 20 Board for measurement of conductivity and C Electronic circuit with variable frequencies adapted to the conventional cells (platinum) and to the special titanium CRISON cells. Automatic scale change to obtain maximum resolution. The cable resistance is automatically compensated by the electronic circuit. EC EC E.C. + 44 30 Board for dissolved oxygen measurement with amperometric sensor, with membrane Salinity and atmospheric pressure correction by manual data introduction. During calibration, the current reading of the electrode is shown, giving indications about electrode conditions. Calibration possibilities: - In one point in air with 100% relative humidity. - Manual calibration at any value at the measuring range. D.O. + (amperometric) D.O. D.O. 44 40 Board for dissolved oxygen measurement with optical sensor (fluorescence) The communication between the sensor and the board uses the protocol MODBUS. Manual calibration at any value at the measuring range. O.D. O.D. D.O. + (Optical) 44 50 Board for measurement of free residual chlorine Double signal entrance: - Amperometric electrode, gold-cupper. - Redox electrode, platinum. The instrument works exclusively with one of the two sensors. The amperometric electrode calibrates manually against DPD 1. The instrument, thanks to the sensor alarm detects automatically the possible flow drop. Cl2 + Cl2 mv Cl2 MultiMeter 44 5

MultiMeter 44 Communications Apart from the two outputs per each measuring channel, MultiMeter 44 offers several possibilities for digital communication. RS 232 Interface MultiMeter 44 in all versions includes RS 232 interface that can be used for: Extracting the information from the Data Logger. For this purpose memory module must be connected directly to the external MP-5 connector. Sending alarm messages through GSM to a mobile phone. Communication with a for data sending on-line, or data extraction from the Data Logger. The data can be captured with standard application as Hyperterminal of Windows. RS-232 GSM Memory module RS-232 RS-232 RS 485 interface (optional) Under order MultiMeter 44 can be supplied with RS 485 interface. In this way, several instruments can be connected to one. For this, a RS 485 / USB convertor is required. The CRISON application MM 485 makes easy the data acquisition. RS-485 RS-485 Convertor USB PROFIBUS DP output (optional) Under order MultiMeter 44 can be supplied with PROFIBUS DP output. PROFIBUS allows the global integration of information proceeding from different instruments. This is a standard protocol available in the majority of control systems in factories. PROFIBUS DP 6 MultiMeter 44

Specifications Measuring range...with ph board ph -2.00... 16.00 mv, ± 2000 Temperature, -20... 150 C...with EC board EC, 0.1 µs/cm... 500 ms/cm Salt, 5 mg/l... 278 g/l NaCl T.D.S., 0... 199 g/l Resistivity, 5... 100 M Temperature, -20... 150 C...with DO board (Amperometric)...with DO board (Optical) % saturation, 0... 200 % Concentration, 0... 20 mg/l Temperature, 0... 50 C % saturation, 0... 250 % Concentration, 0... 25 mg/l Temperature, 0... 50 C...with Cl 2 board Concentration, 0... 5 mg/l Temperature, 0... 100 C mv, ± 2000 (with redox electrode) Temperature sensor Pt 1000 for ph, EC and Cl 2 NTC for DO Calibration with standards ph, 1, 2 or 3 buffers among ph 2.00, 4.01, 7.00, 9.21 and 10.90 at 25. mv, in 1 point, 220 mv at 25. EC, 1, 2 or 3 standards among 147 µs/cm, 1413 µs/cm, 12.88 ms/cm and 80.4 ms/cm at 25 C. DO (Amperometric) in 1 point in air with relative humidity 100 %. Indirect calibration Readjusting any ph, mv, EC, DO, chlorine or temperature value. Measuring control ON/OFF and Proportional. Programmable analogical outputs Two per measured channel. 4...20. Maximum R. 500. Communication RS 232. RS 485 and PROFIBUS (optional). Relays Contacts, maximum charge: CA < 250 V / < 3 A / < 750 VA. Manual verification of installation Relays actuation and outputs. SMS message sending. Languages Spanish, Italian, English and Catalan. Display Graphic, backlit liquid crystal, 128 x 64 dots. Keypad 7 keys membrane. Material PET with protective treatment. Power supply 230 ±10 %, 45-65 Hz (other tensions, please consult). Consumption 6 VA. Protection: class II. Overvoltage category: II. Electrical security According to UNE-EN 61010-1 E.M.C. (Electromagnetic compatibility) According to CE, UNE-EN 61000-6-1:2002, UNE-EN 61000-6-2:2002, UNE-EN 61000-6-3:2002/ A11, UNE-EN 61000-6-4:2002. Ambient conditions Working temperature: 0...50. Storage temperature: -20...65. Relative humidity < 80 %. Enclosure IP 65 protection. Material, ABS. Physical parameters Weight 1800 g. Size: 210 x 215 x 100 mm. How to order MultiMeter 44 Code Basic instrument 44 00 MultiMeter 44, wall-mounting, 220 VCA 44 01 MultiMeter 44, wall-mounting, 24 VCA 44 02 MultiMeter 44 P, panel-mounting, 220 VCA 44 03 MultiMeter 44 P, panel-mounting, 24 VCA NOTA: To order instruments with the option RS 485, add 485 to the code 44 0X. To order instruments with the option PROFIBUS, add PRO to the code 44 0X. Code Electronic boards 44 10... ph / mv + C. 44 20... E.C. + C 44 30... D.O. + C, for amperometric sensor (membrane) 44 40... D.O. + C, for optical sensor (fluorescence) 44 50... Chlorine + C, for amperometric sensor MultiMeter 44 7

Housings for the correct installation of the sensors Ask for specific leaflet Electrodes and housings Código 065-E, Edición Abril 2008 Instruments designed and manufactured in Spain by CRISON INSTRUMENTS, S.A. Riera Principal 34-36 08328 ALELLA Tel. +34 935 409 320 Fax +34 935 559 300 E-Mail info@crison.es www.crisoninstruments.com