Similar documents
IRRIGATION EQUIPMENT LTD. The Perfect Solution for Water Filtration and Irrigation Problems

DLKF. EBARA Submersible Sewage Pumps Specifications Project: Model: Chk d: Date:

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

Service Data Vickers. Piston Pumps. PVH98/106 Variable Displacement Piston Pump - 11 Design M-2208-S. Revised 05/01/97

Industrial Processing Solutions

Commercial, Residential & Institutional Pumps, Tanks, & Accessories

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

Vickers. Service Data. Piston Pumps. PVH57/63 Variable Displacement Piston Pump - 11 Design M-2206-S. Revised 11/01/97

SECTION XXXXX POSITIVE DISPLACEMENT BLOWER WITH SOUNDSEAL COMPACT ENCLOSURE

Model CV-1F Grooved End Swing Check Valves. General Description. Technical Data. Installation. Page 1 of 6 FEBRUARY 2016 TFP1550. Worldwide Contacts

3020/3120 Series DEMING PUMPS. Frame-mounted and close-coupled Enclosded and semi-enclosed impeller Capacities to 4,000 GPM Heads to 780 feet

1600 Series Rotating Suction Screen

Vertical Heavy Duty Pumps

CombiChem. Centrifugal pumps according to ISO 5199 and ISO 2858 / EN (DIN 24256)

Encyclon Inc. Cyclonic Filtration Systems

VSA SEWAGE PUMP. Capacities to 1600 gpm, Heads to 120, Horsepower range 3/4 thru 40, 3 thru 6 discharge, 1750 and 1150 operation.

MODEL 652A MODEL 654A MODEL 652A MODEL 653A MODEL 651A AURORA. 650 Series SINGLE STAGE SOLIDS HANDLING PUMPS

Family Curve. Submersible Grinder Pumps 1¼" and 3" Discharge. Effluent/Grinder Pumps.

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

380 Series Multi-Stage Centrifugal Pumps

COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ. Steady-State Efficiency - up to 81% Input - 30,000 to 75,000 Btuh

Family Curve. Submersible Grinder Pumps 1¼" and 2" Discharge. Effluent/Grinder Pumps.

Tel Group

STATION MODEL: KPCG21-24x48 PUMP MODEL: KEEN KPCG21 VOLTAGE: 230 PHASE: 1 TANK DIMENSIONS: 24 DIAMETER X 48 DEEP

Service Data Vickers. Piston Pumps. PVH74/81 Variable Displacement Piston Pump - 11 Design M-2207-S. Revised 11/01/97

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

568X, 587X, 588X Series

SECTION AIR COMPRESSORS AND ACCESSORIES

Beverage Processing System

End-Suction Centrifugal Pump

End-Suction Centrifugal Pump

STAINLESS STEEL UNITS

Owner's Manual. (200 Gallon Lawn Service Skid Sprayer) Technical Specifications. Operation. General Information. Warranty/Parts/Service

Propeller Fans. Industrial And Commercial Fans Belt And Direct Drive. Your Clean Air Source!

Vacuum filters. Established for industrial dewatering

Roto-Jet I & II Tube Cleaning Systems

Wilo IL Vertical Split-Coupled Inline Pumps

Models Series Series

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

380 Series Multi-Stage Centrifugal Pumps

569, 570, 571, 572 Series

MODEL PR16 POWER ROTARY

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

KEENER GRINDER PUMPS

TM Series. Induced Draft, Counter Flow Optional Accessories

SECTION PLUMBING EQUIPMENT Piping (Plumbing). 2. Division 16 - Electrical Wiring and Connections.

Our Purifier systems

Goulds Large Capacity, Single Stage, Double Suction Pump

TITAN FLOW CONTROL, INC.

GH Series End Suction Centrifugal Pumps For Flows to 2,500 GPM

46920 County Rd E Center, CO Phone: Fax: Pump Rebuild Report. Union/Flowserve 6x8 MQF, 7 stage

GRAVITY SCREEN FILTER

OPERATION AND INSTRUCTION MANUAL NORCLEAN POWERED EDDY CURRENT VACUUM RECOVERY SYSTEM WITH WATER TRAP OPTION

InterSeptor Centrifugal Separators Operating & Maintenance Manual

TURBO AND HIGH PRESSURE REGENERATIVE BLOWERS

(2) 325 tpd York Chlorine Liquefier Systems

Packaged Semi-Instantaneous Steam Fired Water Heater

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

Quality & Service Since For the Reduction of Metal Turnings to Shoveling Chips for Briquetting or Pneumatic Conveying

DNJ SERIES PUMPS END SUCTION CLOSE COUPLED

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

J SERIES. Technical Specifications. Centrifugal Pumps for J Series Condensate & Boiler Feed Pumps. Features

569, 570, 571, 572 Series

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

SERVICE MANUAL. 300 Series Motorized 35650, 35651, 35652, 36750, 36751, and Model

Ampco s Complete Line of AC SERIES PUMPS AC, AC+, IC+

Deluge Valves. Model 68 DE\ EL. Electrically Actuated Remote-Reset Deluge Valve. Dorot Fire Protection Division. Certification & compliance by design

INSTALLATION AND SERVICE MANUAL FOR THE TAC1000-P FAN SERIES (PNEUMATIC CONTROL) TAC1000-H FAN SERIES (HYDRAULIC CONTROL)

Models Series Series

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

Model 6050-Series. PumpAgents.com - buy pumps and parts online SELF-PRIMING PUMPS. Model 6050-Series

Taco 00 Series Cartridge Circulators

INSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 1

Posi-Drain. A non-clogging straight-through flow path design. Removes condensate, (oil and water) from compressed air systems.

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

BASCO TYPE T and TC MOISTURE SEPARATORS and TRAP. ...world leaders in heat transfer technology

Semi-Automatic Suction Screen Filters 3"-4 Angle. Service & Maintenance Manual

Turbo-blowers and Turbo-compressors

Experience In Motion. WXH and WXM Utility-Grade Multistage Ring Section Pumps

Crushers, Mills and Stock Treatment

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V.

THREADING TURNING MILLING BROACHING RUBBING HONING SPINNING LAPPING HOBBING DRILLING

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 21 Fire Suppression 3000 Fire Pumps

.2 Section Waste Management and Disposal..5 Section Motors, Drives and Guards for Mechanical Systems.

ASEPTIC SAMPLING VALVES SANITARY SAMPLING VALVES SANITARY SAMPLING BOTTLE TANK BOTTOM ASEPTIC VALVE

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS

1 1/8 Inch Centrifugal Pump Operation and Maintenance Guide

Metso in filtration. Mechanical dewatering by pressure

Air. Pressure. Motion. nnnnnnnn

Autotrol Performa FA Valve

INSTRUCTION AND REPAIR MANUAL

SERIES 24. Series 24 Features. Commercial, Forced Draft, Hot Water or Steam Boiler. The right fit for any commercial job

Condensate Boiler Feed Water Make-Up

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS

High Capacity Instantaneous Steam Fired Water Heater

Hi-Pres. Self Contained A/C Unit HI-PRES MARINE & OFFSHORE

Ribbon Blenders and other horizontal mixers

Transcription:

Water Strainers

S.P. KINNEY MODEL A STRAINER APPLICATIONS The Model A is designed for continuous removal of suspended particles from all types of liquids. Applications are in industrial plants using river, lake, well, or sea water for cooling, descaling, bearing lubrication, spraying, quenching, and similar purposes. Pipe line sizes: - or larger upon application. Liquids other than water, such as chemicals, acids, white water (paper mills), sewage, and ammonia flushing liquor (coke plants) can also be effectively strained. INSTALLATION Installation is made on the discharge side of a pump or in any piping system operating under a positive pressure. The mini mum working pressure required to effectively clean the strain ing media is 0 psi. The strainer is compact with small face- to-face, width, and height dimensions. AUTOMATIC BACKWASH CONTROL In lieu of a manually operated backwash valve, an automatic control can be furnished to permit intermittent backflushing. This control consists of an electric or pneumatically operated ball valve, actuated by a timer or a pressure differential switch (or both). ADJUSTMENT AND SHEARING ACTION The clearance between the backwash slot and the drum is equal to or smaller than the opening presented in the media and can be adjusted easily by two locknuts on the threaded part of the top section of the shaft. DESIGN The strainer consists of a conical drum with a number of threaded holes containing one of many types of straining media. The drum is supported on a rotating shaft fitted with bearings and is contained in a body having a vertical backwash slot opening adjacent to the drum surface. OPERATION The liquid to be strained enters the inlet connection located in the lower portion of the body and flows around the outer surface of the drum. The suspended particles are retained in the media pockets, and the clean liquid passes through the media to the inside and bottom opening of the drum. The clean water can then continue through the outlet connection located diametrically opposite the inlet. BACKWASH As each row of straining media passes the backwash slot, a reversal of flow occurs, flushing the suspended particles from the media pockets. This reversal of flow is caused by a pressure differential between the interior of the strainer and the atmosphere. The backwash flow rate is exceptionally low and will vary, depending on the amount of suspended particles in the liquid. The backwash slot con tains a knife-like edge which enables the strainer to shear debris such as wood, shells, fish, and other suspended mate rials which may extend beyond the surface of the drum with no resultant damage to the drum, straining media, or drive unit. INSPECTION The Kinney Model A strainer eliminates troublesome disassembly by providing an opening in the side of the strainer body. To inspect the straining media, simply remove the cover and manually rotate the drum. As each row of media passes the inspection opening, easy access to the media is achieved.

CUSTOM BUILT IN THE U.S. All S.P. Kinney strainers are custom built to order in the United States using only the highest grade American steel. CALL TODAY Call us today at 1-800--1118 or visit www.spkinney.com to set up a free consultation. STRAINER SIZE-A 8 10 1 1 1 0 0 MODEL A CAST DIMENSIONS (inches) B C D E F G H 18 18. 18. 1 1 1 7 8 90 1 1 1..1 8. 9.7 10. 10. 1 17... 7.. 9 9. 11 1. 1. 19. 0 17.7 1. 7 8 9. 9.7 0. 79.87 81 10 107 119.7 1. 1. 17.7.7.7 8. 10.7 1.1 1 17.1 19.1.7 8.. 9.7 1. 1. * * * * * *. 9 0.7 80. 89.7 111.87 11 19.7 18 17.7 19.7. 9. MOTOR H.P.....7.7.7 1 1 1. 1. APPROX. SHIP WT. LBS 0 1,00 1,800,00,80,00 8,00 11,000 1,700 18,00 7,000,000 PART Body Drum Media Media Retainers Shaft CONSTRUCTION STANDARD SEA WATER WHITE WATER AMMONIACAL LIQUOR Cast Iron Cast Iron As Specified Delrin Steel Cast Iron Cast Iron Aluminum Bronze Stainless Steel As Specified As Specified Delrin Delrin Stainless Steel Stainless Steel Cast Iron Cast Iron As Specified Stainless Steel Stainless Steel *Two backwash openings **Dimensions provided above are for reference only. Actual dimensions shall be provided on certified drawings when order is placed. ***Additional sizes and variations may be available for custom builds. Please call for information.

S.P. KINNEY MODEL AP STRAINER APPLICATIONS The Model AP is designed for continuous removal of suspended particles from all types of liquids. Applications are in industrial plants using river, lake, well, or sea water for cooling, descaling, bearing lubrication, spraying, quenching, and similar purposes. Pipeline sizes: - or larger upon application. Liquids other than water, such as chemicals, acids, white water (paper mills), sewage, and ammonia flushing liquor (coke plants) can also be effectively strained. AUTOMATIC BACKWASH CONTROL In lieu of manually operated backwash valves, an automatic control can be furnished to permit intermittent backflushing. This control consists of electric or pneumatically operated ball valves (one at the backwash inlet and one at the backwash outlet), actuated by a timer or a pressure differential switch (or both). ADJUSTMENT AND SHEARING ACTION The clearance between the backwash slot and the drum and the clearance between the drum and the backwash shoe is INSTALLATION Used when working pressure is low. The strainer is compact - with small face-to-face, width, and height dimensions. DESIGN The Model AP strainer consists of a conical drum with a number of threaded holes containing one of many types of straining media. The drum is supported on a rotating shaft fitted with bearings and is contained in a body having a vertical backwash slot opening. A pressure backwash shoe is inserted inside the drum, directly opposite the backwash slot. OPERATION The liquid to be strained enters the inlet connection located in the lower portion of the body and flows around the outer surface of the drum. The suspended particles are retained in the media pockets, and the clean liquid passes through the media to the inside and bottom opening of the drum. The clean water can then continue through the outlet connection located diametrically opposite the inlet. BACKWASH High pressure liquid from the discharge side of the pump or from some other source is diverted to the backwash shoe. As each row of straining media passes between the backwash shoe and the backwash slot, the high pressure liquid flushes the suspended particles from the media. The amount of high pressure liquid needed to effect proper backflushing is low and will vary, depending on the amount of suspended particles in the liquid being strained. equal to or smaller than the opening presented in the media. Adjustment of the clearance between the backwash slot and the drum is accomplished by two locknuts on the threaded part of the top section of the shaft. The clearance between the drum and the backwash shoe is adjusted at the bottom of the backwash shoe. The backwash slot contains a knife-like edge which enables the strainer to shear debris such as wood, shells, fish, and other suspended materials which may extend beyond the surface of the drum with no resultant damage to the drum, straining media, or drive unit. INSPECTION The Kinney Model AP strainer eliminates troublesome disassembly by providing an opening in the side of the strainer body. To inspect the straining media, simply remove the cover and manually rotate the drum. As each row of media passes the inspection opening, easy access to the media is achieved.

CUSTOM BUILT IN THE U.S. All S.P. Kinney strainers are custom built to order in the United States using only the highest grade American steel. CALL TODAY Call us today at 1-800--1118 or visit www.spkinney.com to set up a free consultation. STRAINER SIZE-AP 8 10 1 1 1 0 0 MODEL AP CAST DIMENSIONS (inches) B C D E F G H J K 18 18. 18. 1 1 1 7 8 90 1. 1. 1..1 8. 9.7 10. 10. 1 17... 7. 9 9. 11 1. 1. 19. 0. 8 9. 9 9 9.7 8. 79.87 81 10 107 1 1. 180 19..7.7.7 8. 10.7 1.1 1 17.1 19.1.7 8.7.7 0 * * * * * * 9 9 9 7.87 97. 108.1 18.7 10 19. 19. 09. 10.7 81. 0. 7 7 7. 8.1 8. 9. 9.. 8.7. 7. 1. 1. 1. 1. 1.. MOTOR H.P.....7.7.7 1 1 1. 1. APPROX. SHIP WT. LBS 1,0 1,890,00,00,0 8,900 11,0 1,90 19,80,00 1,000 CONSTRUCTION PART STANDARD SEA WATER WHITE WATER AMMONIACAL LIQUOR Body Cast Iron Cast Iron Cast Iron Cast Iron Drum Cast Iron Aluminum Bronze Stainless Steel Cast Iron Media As Specified As Specified As Specified As Specified Media Retainers Delrin Delrin Delrin Stainless Steel Shaft Steel Stainless Steel Stainless Steel Stainless Steel Backwash Shoe Cast Iron Aluminum Bronze Stainless Steel Cast Iron *Two backwash openings. **Dimensions provided above are for reference only. Actual dimensions shall be provided on certified drawings when order is placed. ***Additional sizes and variations may be available for custom builds. Please call for information.

S.P. KINNEY MODEL AFW-1 STRAINER APPLICATIONS The Model AFW-1 is a light duty strainer designed for continuous removal of suspended particles from all types of liquids. Applications are in industrial plants using river, lake, well or sea water for cooling, descaling, bearing lubrication, spraying, quenching and similar purposes. Pipeline size: -8. Liquids other than water, such as chemicals, acids, white water (paper mills), sewage plants, and ammonia flushing liquor (coke plants) can also be effectively strained. INSTALLATION Installation is made on the discharge side of a pump or in any piping system operating under a positive pressure. The minimum working pressure required to effectively clean the straining media is 0 psi. The strainer is compact with small face-to-face width and height dimensions. Installation can be made in a horizontal or vertical pipeline. DESIGN Similar to many of the automatic strainers on the market, the Model AFW-1 consists of a one-piece stainless steel cylindrical well screen drum with slotted openings ranging from.00 through.07. Within the drum is contained a rotor, which is essentially a hollow rotating shaft supporting two pads extended on each side. These pads are flush with the inside of the drum surface. OPERATION The liquid to be strained enters the inlet connection located in the lower portion of the body and flows upward into the inner surface of the drum. The suspended particles are retained, and the clean water can then continue through the outlet connection located diametrically opposite the inlet. BACKWASH As the rotor sweeps over the drum, a reversal of flow occurs, flushing the suspended particles from the media into the rotor and out through the backwash opening. This reversal of flow is caused by a pressure differential between the interior of the strainer and the atmosphere. The backwash flow rate is exceptionally low and will vary, depending on the amount of the suspended particles in the liquid. The backwash piping should discharge downward into an open funnel immediately after the backwash valve. AUTOMATIC BACKWASH CONTROL In lieu of a manually operated backwash valve, an automatic control can be furnished to permit intermittent backflushing. This control consists of an electric or pneumatically operated ball valve, actuated by a timer or a pressure differential switch (or both).

STRAINER SIZE-A 8 10 1 1 1 18 0 0 MODEL AFW-1 STRAINERS DIMENSIONS (inches) B C D E F G H 18 18. 18. 1 1 8 8 7 * * *.... 7 9.7.7. 7. 8. 10. 1. 1. 18. 17. 17. 0 7 7 9..87 0. 8.7 1. 7.1 70. 70. 90. 89. 99. 11.1 10. * * * 8. 9. 11 1 1.7 1.7 19.1 19.1.7 9. 1. 1. 9. 8 7. 78.87 99.7 99.7 10 19 1. 1.1 181 MOTOR H.P..........0.0.0.0.0.0 APPROX. SHIP WT. LBS 70 0 0 90 1,00 1,0,000,70,0,0,77 7,00 9,0 1,000 CONSTRUCTION PART STANDARD SEA WATER WHITE WATER AMMONIACAL LIQUOR Body Cst Iron or Fab Stl Cast Iron Cast Iron/Stn. Stl Cast Iron Drum-Wedge Wire Stainless Steel Stainless Steel Stainless Steel Stainless Steel Media (Str. Opening) As Specified As Specified As Specified As Specified Rotor Cast Iron Stainless Steel Stainless Steel Cast Iron *Two backwash openings **Dimensions provided above are for reference only. Actual dimensions shall be provided on certified drawings when order is placed. ***Additional sizes and variations may be available for custom builds. Please call for information. CUSTOM BUILT IN THE U.S. All S.P. Kinney strainers are custom built to order in the United States using only the highest grade American steel. CALL TODAY Call us today at 1-800--1118 or visit www.spkinney.com to set up a free consultation.

S.P. KINNEY MODEL AM STRAINER APPLICATIONS The Model AM is a manual strainer designed for removal of suspended particles from all types of liquids. Applications are in industrial plants using river, lake, well, or sea water for cooling, descaling, bearing lubrication, spraying, quenching, and similar purposes. Pipe line sizes: -. Liquids other than water, such as chemicals, acids, white water (paper mills), sewage, and ammonia flushing liquor (coke plants) can also be effectively strained. INSTALLATION Installation is made on the discharge side of a pump or in any piping system operating under a positive pressure. The minimum working pressure required to effectively clean the straining media is 0 psi. The strainer is compact with small face-to-face width and height dimensions. DESIGN The strainer consists of a straight drum with a number of threaded holes containing one of many types of straining media. The drum is supported on a rotating shaft which can be turned manually with a hand crank in a body having a vertical backwash slot opening adjacent to the drum surface. INSPECTION The Kinney Model AM strainer eliminates troublesome disassembly for cleaning and inspection by providing an opening in the side of the strainer body. To inspect the straining media simply remove the cover and manually rotate the drum. As each row of media passes the inspection opening, easy access to the media is achieved. OPERATION The liquid to be strained enters the inlet connection located in the lower portion of the body and flows around the outer surface of the drum. The suspended particles are retained in the media pockets, and the clean liquid passes through the media to the inside and bottom opening of the drum. The clean water can then continue through the outlet connection located diametrically opposite the inlet. BACKWASH The drum is manually turned, and as each row of straining media passes the backwash slot a reversal of flow occurs, flushing the suspended particles from the media pockets. This reversal of flow is caused by a pressure differential between the interior of the strainer and the atmosphere. The backwash flow rate is exceptionally low and will vary, depending on the amount of suspended particles in the liquid. BACKWASH CONTROL A manually operated valve is supplied for installation on the backwash outlet line to permit intermittent backflushing. ADJUSTMENT AND SHEARING ACTION The clearance between the backwash slot and the drum is equal to or smaller than the opening presented in the media. The backwash slot contains a knife-like edge which enables the strainer to shear debris such as wood, shells, fish, and other suspended materials that may extend beyond the surface of the drum with no resultant damage to the drum or the straining media.

CUSTOM BUILT IN THE U.S. All S.P. Kinney strainers are custom built to order in the United States using only the highest grade American steel. CALL TODAY Call us today at 1-800--1118 or visit www.spkinney.com to set up a free consultation.

S.P. KINNEY MODEL FF AND CUSTOM STRAINERS APPLICATIONS S.P. Kinney offers a wide range of custom manual and automatic designs to meet any dimensional, pressure, or temperature requirements that a customer may have. If your custom needs fall outside our standard product offerings, please contact us directly so our engineering team may put together a custom water filtration package designed specifically for you. CUSTOM BUILT IN THE U.S. All S.P. Kinney strainers are custom built to order in the United States using only the highest grade American steel. CALL TODAY Call us today at 1-800--1118 or visit www.spkinney.com to set up a free consultation.

S.P. KINNEY ENGINEERS, INC. 1 FIRST AVE. P.O. BOX, CARNEGIE, PA 110-0, USA PHONE: 1-800--1118 FAX: (1) 7-890 WWW.SPKINNEY.COM INFO@SPKINNEY.COM