Total Articulating Service Column - TASC 2000 Series lements The TASC Pendant is available in single and double arm configurations ach joint has a rotation range up to 330 Pendant head can be custom-designed to accommodate a large variety of medical gas outlets and electrical devices Pnuematic brake is available to lock the pendant once it is placed into position quipment carrier is available to combine workplaces and save space in the room Description The TASC 2000 Series Pendants are designed to conveniently dispense medical gas and electrical services in the operating room suite or intensive care environment. The TASC Pendant is available in a single or double arm configuration and with or without vertical movement. The pendant arm has rotation at the ceiling, at the elbow of the upper and lower arm, and at the pendant head. The medical gas and electrical systems are complete for single point connection to each gas service and electrical circuit at the mounting platform. The mounting platform shall be designed to support the arm and the optional equipment carrier. The platform shall include 6" long pigtails, with gas specific DISS connections for mistake-free installation. The support platform will also include an electrical junction box. The arm length of the TASC 2401 is 39.4" (1000 mm) from the center point of the ceiling tube to the pendant head. The arm length of the TASC 2402 is 39.4"(1000 mm) for the upper arm and 39.4" (1000 mm) for the lower arm. The arm length of the TASC 2831 is 35.4" (900 mm) from the center point of the ceiling tube to the pendant head. The arm length of the TASC 2832 is 39.4" (1000 mm) for the upper arm and 35.4" (900 mm) for the lower arm. ach pivoting point of the arm has permanentlylubricated rotating bearing and adjustable stops for controlling the degree of rotation. ach pivoting point has the capability of up to 330 lateral rotation. The electrical motor system shall control the up and down vertical deflection of the pendant head through 23.6" (600 mm) of travel. The power requirements for the motor shall be 115 volt/1 phase/60 hertz. The pendant head shall be designed for a maximum of 10 medical gas outlets (quick connect or DISS), and any combination of 10 electrical outlets, grounding jacks, or monitoring receptacles. The pendant head will remain in its working position at all points along the 330º arc of travel and in any vertical position, even with an electrical supply failure. All medical gas outlets (quick connect and DISS) are color-coded and labeled for quick identification. An equipment carrier can be attached to the pendant head to position shelves for monitors and other surgical or critical care equipment. The shelves can be equipped with drawers, brackets, and rail systems. The carrier improves space management by locating equipment from the floor to the pendant.
Product Data Technical Data Ceiling Mounting Support System Height Adjustments Pendant Head Supply Terminals Suspended ceiling depth up to 1200 mm Mounting on concrete ceiling with heavy-duty anchor Maximum moment on structural ceiling - 3000 Nm Approximate weight TASC 2401 77 lbs (35 kg) TASC 2402 110 lbs (50 kg) TASC 2831 110 lbs (50 kg) TASC 2832 154 lbs (70 kg) Ceiling heights TASC 2401 100.80" to 134.25" TASC 2402 106.30" to 139.80" TASC 2831 104.30" to 157.50" TASC 2832 110.00" to 141.70" Length of support arm TASC 2401 1000 mm (39.37") TASC 2402 1000 mm (39.37")/1000 mm (39.37") TASC 2831 900 mm (35.43") TASC 2832 1000 mm (39.37")/900 mm (35.43") Maximum loads TASC 2401 100 kg TASC 2402 40 kg TASC 2831 70 kg TASC 2832 70 kg AC electric motor - single phase - 110/60hz Lifting range - 600 mm (23.62") Rotation range - gradually adjustable up to 330 Medical gas outlets Maximum 10 gas and/or vacuum lectrical outlets Maximum 10 electrical power sockets
TASC 2401/2402 TASC 2401 Quantity TASC 2402 Quantity
TASC 2831/2832 TASC 2831 Quantity TASC 2832 Quantity
CILIN MOUNTIN PLATFORM Figure 1: Ceiling Support Structure xample Installing the TASC Ceiling Mounting Platform 1. The ceiling mounting platform is equipped with the necessary medical gas pigtails to allow the contractor to connect to the piping system. 2. The mounting platform is available for delivery prior to the shipment of the complete Pendant. Once the mounting platform is installed the ceiling can be completed. 3. The Pendant is mounted directly to the mounting platform.
ORDRIN INFORMARION Chemetron Ceiling Pendents are manufactured to customer specifications. The following steps must be completed prior to the manufacture of the ceiling column. Step 1 Indicate the style of pendent. Style TASC 2401 TASC 2402 TASC 2831 TASC 2832 Step 2 Indicate the ceiling height of the room in which the ceiling column will be located. The ceiling column is designed for heights of 8 6 to 10 0. Ceiling heights less than 8 6 will require sub-mounting. Ceiling Height Step 3 Select standard for medical gas outlets U.S. Style Quantity ISO Style Notes eneral information to remember when selecting the devices in a ceiling column: To ensure proper position of medical gas and electrical outlets, position the as and lectrical ID in the desired location. The gas and electrical outlets must be separated into the left and right side of the pendant head. If 10 medical gas outlets are selected, a maximum of 4 vacuum and evacuation outlets can be installed. Normal and emergency electrical receptacles cannot be located in the same row of outlets. These devices cannot be installed into the same electrical back box. Specify color for electrical duplex outlets (Normal, mergency) Monitor receptacles should be wired under monitor manufacturer s recommendations for proper shielding. Adjacent electrical receptacles will be provided in double or triple configurations with common back box and cover. Adjacent ground receptacles or other adjacent electrical receptacles of the same type will be furnished with common back box and cover plate for installation convenience. Location 8 on the selection table is not available on Models 2831 and 2832. This location contains the vertical movement switch. Step 4 Select the style of medical gas outlet installed in the ceiling column. If nitrogen is used in the column indicate the style of outlet to be installed Chemetron Quick-Connect Oxequip Quick-Connect Nitrogen Dyna-Con Connect2 Medaes Compatible DISS DISS Puritan Bennett Quick-Connect Schrader Step 5 The drawing on the next page shows the views of the pendant head. On the selection grid indicate the location of the medical gas and electrical devices required on the pendant. If a location does not require a device a blank plate will be installed. As shown on the grid, medical gas and electrical outlets cannot be located in the same plate, they must be separated.
Ordering information and Outlet COnfiguration 10 9 10 9 Back View 7 1 2 3 1 2 3 7 8 4 5 6 4 5 6 8 Side View Front View Medical as/lectrical Services and Types Side View Medical as Service QC DISS 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 Oxygen Outlet Vacuum Outlet Air Outlet N2O Outlet Nitrogen Outlet Not Available vacuation Outlet Carbon Dioxide Outlet CO2/O2 < 7% lectrical Service 115V 220V 20 Amp Receptacle Red 20 Amp Receptacle Ivory Twist Lock 20 Amp round Receptacle Not Available Double round Receptacle Remote Monitor Provision -K 5-Pin 37-Pin Monitor Receptacle
Accessories Accessory Quantity Weight Catalog # Universal quipment Carrier 490 mm Wide 24.1 lbs. 81-25-0001 690 mm Wide 28.5 lbs. 81-25-0002 quipment Carrier Respiratory Monitoring 490 mm Wide 42.4 lbs. 81-25-0003 690 mm Wide 51.8 lbs. 81-25-0004 quipment Rods 700 mm Long 4.2 lbs. 81-25-0010 900 mm Long 7.5 lbs. 81-15-0011
Accessories Accessory Quantity Weight Catalog # quipment Consoles 600 mm Wide 9.7 lbs. 81-25-0020 800 mm Wide 13.9 lbs. 81-25-0021 Deposit Console 5.1 lbs. 81-25-0022 Console for Swiveling Rail 0.9 lbs. 81-25-0023 Shelves (1-drawer model shown) 1 Drawer 25.2 lbs. 81-25-0030 2 Drawers 33.3 lbs. 81-25-0031 Parallel Rails 600 mm Wide 2.7 lbs. 81-25-0040 800 mm Wide 3.6 lbs. 81-25-0041
Accessories Accessory Quantity Weight Catalog # Double Swiveling Rail 1.4 lbs. 81-25-0050 Compact Rail 2.0 lbs. 81-25-0051 Support Rail 0.9 lbs. 81-25-0052 Surrounding Rails Inside (shown as smaller rail) Outside (shown as larger rail) 4.2 lbs. 81-25-0053 4.9 lbs. 81-25-0054 Surrounding Rail, Small 4.2 lbs. 81-25-0055
Accessories Accessory Quantity Weight Catalog # Wire Baskets 200 mm Deep (shown on right) 300 mm Deep (shown on left) 600 mm Deep (shown in middle) 1.0 lbs. 81-25-0070 1.0 lbs. 81-25-0071 1.0 lbs. 81-25-0072 Hinged Arm 2.2 lbs. 81-25-0074 Infusion Support (IV Bottle holder 6 hooks) 4.4 lbs. 81-25-0074 CVP Pole 3.6 lbs. 81-25-0075 Cable Holder Set (shown on left) Rail Clips (10/set) (shown on right) 1.0 lbs. 81-25-0076 1.0 lbs. 81-25-0077
Accessories Accessory Quantity Weight Catalog # Twin Bracket Clamp 0.5 lbs. 81-25-0078 Pneumatic Brake 1.1 lbs. 81-25-0100 Suction Bottle Slide Adapter 81-25-0101 Shelf with Writing Surface 17.0 lbs. 81-25-0120
Accessories Accessory Quantity Weight Catalog # Swivel Cabinet with 1 Drawer 6.6 lbs. 81-25-0121 Swivel Cabinet (with 2 Drawers shown) with 2 Drawers 8.8 lbs. 81-25-0122 with 3 Drawers 11.1 lbs. 81-25-0123 Cable Remote Control 0.7 lbs. 81-25-0200 All specifications are nominal and subject to change without notice. Warranty See Allied Statement of Warranties for details 2001 Allied Healthcare Product, Inc. Printed U.S.A. Form No. 81-00-2000 May 2001 Customer Service: USA: (800) 444-3940 FAX: (800) 477-7701 Canada/ Mexico: (800) 446-0552 FAX: (800) 246-6201 International: (314) 268-1683 FAX: (314) 771-5183 1720 Sublette Avenue St. Louis, MO 63110 USA (314)771-2400 www.alliedhpi.com ISO 9001 CRTIFID