FOREST FIRE CONTINGENCY PLAN

Similar documents
University of Maryland FIRE EVACUATION PLAN

Emergency Evacuation Plan and Implementation Guidelines The Pennsylvania State University

FIRE EVACUATION PLAN PRATT STREET PARKING GARAGE AND ATHLETIC CENTER POLICE FIRE MEDICAL EMERGENCY

University of Maryland FIRE EVACUATION PLAN NATIONAL DENTAL MUSEUM POLICE FIRE MEDICAL EMERGENCY Anyone discovering excessive heat,

Mulch fires, trash can fires, or other fire outside a building should be reported by the following methods:

Life Safety Plan Updated January 2017

RAMBLER PARK FIRE SAFETY INFORMATION

Emergency Evacuation Plan and Implementation Guidelines The Pennsylvania State University

Mukwonago Community Library Emergency Procedures

Emergency Evacuation Plan and Implementation Guidelines The Pennsylvania State University

Emergency Evacuation Plan South Patterson Building (SPB)

Emergency Evacuation Plan and Implementation Guidelines The Pennsylvania State University BLUE BAND BUILDING ( )

University of Maryland FIRE EVACUATION PLAN Columbus Center POLICE FIRE MEDICAL EMERGENCY - 911

Emergency Evacuation Plan and Implementation Guidelines The Pennsylvania State University ARTS COTTAGE ( )

Emergency Evacuation Plan

Emergency Guidelines Part II. North Campus

Emergency Planning and Preparedness

EMERGENCY INFORMATION

LINDENWOOD UNIVERSITY BASIC EMERGENCY ACTION PLANS

2012 SunTrust Center ERT Annual Review. 919 East Main St. Richmond, VA

Ten-Point Checklist for Emergency Preparedness

COLUMBUS STATE COMMUNITY COLLEGE EMPLOYEE SAFETY MANUAL

Harvard University - OEB Glasshouse Emergency Evacuation Plan

[Name/title] is the Alternate Safety Officer/ Alternate Emergency Coordinator.

FIRE AND FIRE FITTING By Mr. Prashant Sansare

Exit Routes. Introduction/Overview. OSHA Regulations. Exit Route

Emergency Action Plan

FLOOR WARDEN TRAINING 2016

Non-Emergency Direct Line Telephone Numbers. Emergency Direct Line Telephone Numbers

Department of Chemistry Emergency Action Plan

Emergency Evacuation Plan. Kettering Labs. School of Engineering

ANNUAL FIRE SAFETY REPORT OF 2017 SAINT JOSEPH SEMINARY COLLEGE

Fire Safety Guide. Emergency Number:

Business Emergency Plan

FIRE SAFETY PLAN PART 1 BUILDING INFORMATION SECTION. Type of Construction: Combustible Non-Combustible

Agency for Health Care Administration

FIRE SAFETY PRACTICES AND PROCEDURES

Emergency Action Plan

NYU RESIDENTIAL FIRE SAFETY PLAN PART I - BUILDING INFORMATION SECTION

RESIDENT FIRE AND EMERGENCY PREPAREDNESS HANDBOOK

DUKE CLINIC SITE-SPECIFIC FIRE PLAN Part II General Statement. Fire Procedures

American Red Cross and the Centers for Disease Control. Shelter In-Place Overview

September 1, Sincerely, Mike Montgomery Fire Marshal. M.S. Montgomery Fire Marshal

DUNCAN STUDENT CENTER. Emergency Action Plan

Patrick County Horizons Jeb Stuart Hwy. Stuart, Va

Agency for Health Care Administration

FIRE SAFETY PLAN PART 1 BUILDING INFORMATION SECTION

Museum Towers EVACUATION PROCEDURE IN CASE OF FIRE

Family Foster Home Fire Safety Evaluation Checklist Instructions

Fire and Evacuation Guide

Department of Veterinary Medicine

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT SPORTS CENTRE

Learn About Fires Every day, Americans experience the horror of fire but most people don't understand it.

Emergency Evacuation Plan

Evacuation Fire Safety Program

I. Scope: II. Environmental Health and Safety Fire Alarm System Impairment Program - Guideline Revision Date: April, 2018

San Jose State University Building Emergency Team Program

Fire Safety Guide. Emergency Numbers:

Kaufert Laboratory Building Emergency Plan

Fire Safety: At Home & At Work. Volunteer Annual Review 2017

SECTION 7 EVACUATION PROCEDURES

Purpose of Emergency Response Program Emergency Response Team / Leader Evacuation Procedures Building Life Safety System Virtual Evacuation Building

Fire Evacuation Plan Bressler Research Building. UMB POLICE or

Facility Emergency Action Plans

EMERGENCY PROCEDURES FLIP CHART

Annual Fire Safety Report Icahn School of Medicine at Mount Sinai Aron Hall September, 2016

St. John s University Fire Safety Plan

Fire Evacuation Plan Health Sciences & Human Services Library. UMB POLICE or

Safety Manual Section 7 Fire/Life Safety

In just two minutes, a fire can become life-threatening. In five minutes, a residence can be engulfed in flames.

TAMUCC Fire Safety Training

GENERAL AREAS OF INSPECTION

PLAN REVIEW SUBMITTAL GUIDE

Take your keys, coat, and any important information with you.

Fire Safety Checklist

PERSONS NEEDING ASSISTANCE who are unable to quickly walk down the exit stairwells should follow these alternative procedures:

Emergency Contact Information. TO REPORT ANY EMERGENCY (Police, Fire, Ambulance): Plant. (310) Environmental Health and Safety Hotline

Liberal Arts and Humanities. Building # 275. Emergency Evacuation Plan

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT NEW BUILDINGS

1080 Marina Village Parkway, Suite 501 Alameda, CA (510) Fax (510) HVAC DESIGN INTENT

Haecker Hall Building Emergency Plan

Fire Safety Guide. Emergency Number:

Safety And Fire Prevention. A guide to help Community Living Support Staff prepare for, respond to and prevent emergencies in a residential setting.

FIRE EMERGENCY POLICY

November Safety Subject

During the holiday season, electrical fires are one of the leading causes of damage to residential structures. Specific causes included:

FINLEY HALL EMERGENCY EVACUATION PLAN

October 1, Full *2 Sprinkler System

COUNTY OF ALAMEDA County Administrator s Office Risk Management Unit th Street, 3 rd Floor, Oakland, CA 94607

EMERGENCY TELEPHONE NUMBERS

Emergency Response Procedures

HUDSON VALLEY COMMUNITY COLLEGE BUILDING EMERGENCY ACTION PLAN FOR OUTSIDE EMERGENCY ASSISTANCE: DIAL 911 TO REACH THE SARATOGA CTY POLICE & FIRE

2010 Fire Log Fire Log. Annual Fire Safety Report

Emergency Procedures Quick Reference Guide

Emergency Preparedness Plan

VICI. Emergency Evacuation Plan

UNCONTROLLED IF PRINTED. Issued with the authority of the Chief Commissioner and General Manager of Scouts Australia NSW

Denver Fire Department Fire Prevention Division

EMERGENCY EVACUATION POLICY FOR 100 CHEROKEE STREET BUILDING

St. John s University

Transcription:

LARGE BINOCULAR TELESCOPE OBSERVATORY FOREST FIRE CONTINGENCY PLAN Prepared 8 July 2003 by J. Waack CAN# 004s001c Revised 30 August 2004 by J. M. Hill and L. Vaughn Revised 07 June 2011 by R. Ortega Revised 20 April 2012 by J. K. Little and J. M. Hill CONTENTS: WHAT TO DO IF THERE IS A FOREST FIRE NEAR LBT 2 I. FOREST FIRE IMMEDIATE CHECKLIST 3 II. LOCATIONS OF EMERGENCY SUPPLIES AT LBTO 4 III. SECURE THE LBTO FIXED ENCLOSURE AGAINST FOREST FIRES 6 IV. SECURE THE TELESCOPE AND ROTATING BUILDING 8 V. SECURE THE FIXED BUILDING FOR MINIMAL OCCUPATION 10 VI. LBT ENCLOSURE POWER SHUTDOWN 12 1

WHAT TO DO IF THERE IS A FOREST FIRE NEAR LBT The threat of a forest fire on Mt. Graham is always a distinct possibility. Major fires have occurred near the observatory in 1996 and 2004. In the event of a forest fire, never assume that you should evacuate the site. In fact, never assume anything. The Forest Service should make these decisions. Because of the rough topography of the mountain, it would be impossible to tell exactly where the fire is or if the road is clear. Even if it looks favorable, during the long trip down the mountain the fire could shift and you could easily become trapped. Remain on site at the observatory until you are given clearance to leave. If a forest fire threatens the site, the LBT enclosure is the safest place to be. The building should withstand a fire and keep you safe. Until the designated Incident Commander is on site, follow the instructions of the Responsible LBTO or MGIO personnel. They are trained to handle emergencies such as this. This document describes the specific emergency procedures for the LBTO in case a forest fire threatens. See the MGIO Contingency Plan for more general emergency procedures, emergency phone numbers and radio frequencies. In the event that the Responsible LBTO member (Observatory Manager or Assistant Manager or designee) is not present; designate someone to "take charge". Also get in contact with the Responsible LBTO or MGIO member in case of a fire. Follow the instructions in Sections I, II and III to prepare for fire approaching LBTO. If there is additional time, use the procedures in Section IV to secure the telescope and rotating building. If chilled water/glycol from the MGIO utility building is off and/or if personnel are abandoning the site, follow the additional instructions in Section V to shut down power in the LBT building. 2

I. FOREST FIRE IMMEDIATE CHECKLIST The following is a checklist of things to do at the LBTO/MGIO site when a forest fire threatens. 1) Move as many vehicles as will fit, into the LBTO auxiliary building (high bay). Those that won't fit should be moved away from all buildings, downhill if possible. Also, the remaining vehicles should be parked away from each other and facing toward the escape path (access road). Leave the keys in the ignition. NEVER LEAVE A VEHICLE PARKED BLOCKING THE ROADWAY. 2) LBTO staff should turn off all outside air intake fans by following the procedure in Section III. As time permits, make certain the fixed building is secured. (see Section III of this document for the detailed procedures.) 3) Upon entering the LBTO, follow the instructions of the LBTO staff. If a staff member is not immediately available, the first floor (Level 1) lobby is considered a safe zone. There you will find a list of emergency supplies and their locations. As soon as possible, move to the preferred safe zone, the second floor (Level 2) lounge area. 4) LBTO staff members on site should inform others of the location of available drinking water, food, blankets, oxygen supply, flashlights/ emergency lighting, fire extinguishers, first aid kit, telephone and MGIO communications radios. If there are no LBTO staff members on site, a list of emergency supplies and locations is posted in the lounge area (see Section II of this document). 5) A crown fire in the forest usually moves very quickly (depending on wind, fuel and slope of the terrain). Remain calm, monitor the radio traffic and await further instructions. 6) For communication using the radios: as long as there is electricity, use the base station MGIO radio(s). Save the battery operated hand held radios in case of a power failure. Responsible personnel, to minimize radio traffic and maintain positive communication, should be the only ones using radios. 3

II. LOCATIONS OF EMERGENCY SUPPLIES AT LBTO LBT floor plans are available in the lobby and on the second floor. In the lounge/ kitchen area on Level 2, directly off the stairs/ elevator, you will find an ample supply of bottled water and food. Some additional bottled water may be found in the lobby. A supply of distilled water is in the aux bay on the south wall that can be used in case of emergency, do not leave the safe area unless authorized. Medical oxygen cylinders are located in Level 1 lobby area, outside the observatory manager s office, Level 2 lounge area has 2 cylinders located against the wall, Level 5 and Level 6 outside the elevators, Level 7 behind the locked elevator door. Refer to oxygen cylinder layout map for additional locations. First aid kits are located in the lobby area on Level 1, in the pier outside high bay door 117, Level 2 in the kitchen by the windows, Level 5 outside aux control room 502, on Level 6 there is a small first aid kit with additional eye wash in the galley outside the elevator. In the control room, adjacent to the lounge on Level 2, you will find a list of emergency telephone numbers, flashlights and a base station MGIO communications radio. A portable defibrillator unit, AED, is located in the lounge area on Level 2 by the first aid kit and a second one in the police shack. Do not leave the safe area unless authorized to do so. Blankets and other comfort items can be found in the sleeping rooms located just down the hall from the lounge area on Level 2. Large (on wheels) Type ABC dry chemical fire extinguishers are located on Level 1 (lobby), Level 2 (lounge and hallway) and Level 5 (areas with windows). Medium Type A water fire extinguishers are located in the lobby on Level 1, and in the lounge on Level 2. Small type ABC dry chemical fire extinguishers are 4

located near the elevator lobbies on all levels and at other strategic places around the building. Refer to the fire extinguisher layout map for additional locations. The fire pump and controller for the LBT internal building sprinklers are located on Level 1 in Room 118, Fire Suppression Room. (On the North side opposite the instrument room) The main fire alarm panel PP12B-12 is located in the east end of the electrical equipment room. If the horns go off, follow the instructions on the front of the panel. An auxiliary alarm panel is located in the lobby entryway. 5

III. SECURE THE LBTO FIXED ENCLOSURE AGAINST FOREST FIRES These instructions assume that the LBT building will be occupied during the fire with power on and chilled water/glycol available. These steps are intended to optimize the habitability of the fixed building as a fire burns over, and to minimize the chance of having a structure fire. 1) In the event that an LBTO staff member is not present, designate someone to "take charge". Also get in contact with the Responsible LBTO or MGIO member. Take a "head count" and make certain everyone has signed in and is accounted for. Interface with MGIO and the Forest Service as necessary. 2) Shut off power to the "Outside Air" air handler -- Unit # AH0304. This will stop smoke from being pulled into the fixed building ventilation system for Level 2. This air handler is located on Level 3 Lower, Room 305 (off the north stairwell). Circuit breaker 31 in panel PP22A in computer room B, Room 212, will also shut off AH0304. 3) Shut off power for additional air handlers: a) AH0101, circuit breaker 38 in PP12A, located in the power distribution room 115 across from the substation transformer. b) AH0103, circuit breaker 26 in PP11A, located in the mechanical room 112. c) AH0102, circuit breaker 1 in PP11D, located in the power distribution room 115 across from the substation transformer. d) AH0104, circuit breaker 2 in PP11D, located in the power distribution room 115 across from the substation transformer. e) Close the dampers to the 2 outside air intakes, covers located in the cleaning room 116 need to have the power shut off at the disconnect and have the damper closed. This will stop smoke from being pulled into the fixed building ventilation system for Level 1. One intake is at the west end of the Auxiliary Building high bay (normally closed), and the other is on the north exterior wall (also can refer to section 5 for further details). f) Shut off power to the exhaust fan s EF0303 and EF0302 located on the southeast corner of the aux. bay on Level 1. g) Make sure all bedrooms windows are closed. 6

4) Instruct everyone as to the location of emergency equipment and supplies. Also, instruct everyone to stay away from the windows and to remain in the lounge/ kitchen/ control room area on Level 2 until further instructed. 5) Designate two people to monitor Levels 1 and 2 for window breakage and anything else detrimental to the welfare of personnel or the structure/site. Be certain to monitor all windows from a safe distance from the windows. Large Type "A" fire extinguishers are available on these Levels. All of the exterior windows and the hallway windows are tempered glass. 6) Move furniture and flammables away from the windows on Levels 1 and 2. Raise the dark shades. 7) Close all "fire doors" on Levels 1, 2 & 3. (Hallway doors, etc.) 8) Make certain the MGIO communications radio is turned on and set to the MGIO Repeater channel (Channel 1 = MGIO RPTR). As long as there is electricity, use the base station radio(s). Save the battery operated MGIO radios for use during a power failure. Responsible personnel, to minimize radio traffic and maintain positive communication, should only use radios. In case the Repeater on Heliograph Peak stops working, switch to the MGIO Bypass channel (Channel 2 = MGIO Bypass) for local communications. 9) Move any flammable materials away from the exterior walls of the building. Check the outside of the building as well as the inside of the exterior walls if this can be done safely. Do a good sweep of Level 3 lower. 10) Turn on the FM radio/tv to catch news broadcasts. 7

IV. SECURE THE TELESCOPE AND ROTATING BUILDING As time permits, secure other telescope and enclosure systems in the LBT rotating building. It is especially important to turn off these systems if chilled water/ glycol is not available from the utility building. Otherwise they may overheat. 1) Level 5: Make certain the shutter doors are closed and latched. Make certain the observing chamber ventilation doors are closed. 2) Level 4: Close the Stealth Exhaust Louvers by turning the Local/Remote switches adjacent to the louvers to the off position. 3) Shutdown power to non-essential telescope and enclosure systems. These can be shut down manually from the motor control center on Level 4, simply turn off all the breakers in the motor control center you don t need to worry about which is which. a. Stealth exhaust fans b. Mirror ventilation blowers c. Chillers d. Mirror support air compressors e. Oil central unit for hydrostatic bearings f. Bogie drives g. Rotating building crane h. Shutter drives and vent doors i. Chamber air handlers 4) Move furniture and flammables away from the windows on Level 5. Raise the dark shades. 5) Shutdown the Telescope Computer Systems on Level 5, and the TCS and instrument computer systems on Level 2 (see separate procedure). Usually you will want to keep the networking and firewall systems running while the building is occupied. 8

6) The ventilation louvers in the snow melting system on Level 10 should be closed. This is their normal state, and we rarely melt snow in fire season, so this is very low priority. The key switch in the ECS remote PLC will close these. a) On Level 4 in the ECS remote PLC located across the MCC, is a key switch inside the PLC cabinet for shutting down. You must insert the key and turn to activate shutdown mode to snowmelt, which closes the louvers on Level 10 and the plenum. This key also shuts down stealth fan s on Level 4, shuts down mirror ventilation blower s and closes damper s and shuts down fans, shuts down dome cooling air handler on Level 5, shuts down exhaust fans and closes louvers on Level 4 EF401, EF402. Key will be hanging in the cabinet. 9

V. SECURE THE FIXED BUILDING FOR MINIMAL OCCUPATION These instructions assume that the LBT fixed building will be minimally occupied during the fire with power on but chilled water/glycol off. 1) If you need to shut off glycol at the utility building and secure the utility building: a. You must shutdown the boiler on the first Level of the utility building by turning it to the off position, then shut down fresh intake exhaust fan EF0002 by turning off circuit breaker 27 located in panel AL in the MGIO building on the wall behind the generators. b. Go to second Level in the utility building and turn off the power by closing the disconnect to chiller CH0001, CH0002 then turn off the disconnect to fans P2-1, P2-2, P2-3, P2-4, P2-5 and P1-1, P1-2, P1-3, P1-4, P1-5, P1-6. Shut off the disconnect for fans EF0001 and PH0001-4 also. c. Need to roll down the screens in the utility building on Level 2 - will need ¼ screws, ¼ drill, and ¼ chuck to secure screens down. 2) All of the Computer Systems in the LBT Control Rooms on Level 2 should be shut down if the building does not have cooling water/glycol. (see separate procedure) See the breakers in panel PP22-UPS-1 in computer room A. 3) Turn OFF the circulation air handlers for Level 2 -- Unit AH0301 for the lounge and kitchen is controlled by circuit breaker 32 in panel PP22D in room 235. Unit AH0303 for the sleeping rooms is controlled by circuit breaker 31 in panel PP22D in room 235. Unit AH0302 for the control room is controlled by breaker 32 in panel PP22A in room 212, computer room B. 4) Shut off power to disconnect for the circulation air handlers for Level 1 also refer to section III for further instructions: 10

a. Unit AH0101 for the mechanical room has its own disconnect in room 112 (also controlled by breaker 38 in PP12A located in the power distribution room 115 across from the substation transformer). b. Unit AH0103 for the offices and lobby is controlled by circuit breaker 26 in panel PP11A in mechanical room 112. c. Unit AH0106 for the fixed building elevator has its own disconnect in room 112 (also controlled by breaker 37 in panel PP12A located in the power distribution room 115 across from the substation transformer). Leave AH0106 on if the elevator is in use. d. Unit AH0105 for Storage 118 (Fire Pump Room) is controlled by circuit breaker 22 in panel PP12A. e. Turn OFF air handlers AH0102 and AH0104 by opening circuit breakers 1 and 2 in panel PP11D located in the power distribution room 115 across from the substation transformer). Beware that turning off these air handlers or shutting down the main chillers will result in significant heating of the Electrical Equipment room. 11

VI. LBT ENCLOSURE POWER SHUTDOWN These instructions assume that the LBT building will be completely evacuated during the fire with power off and chilled water/glycol off. If time permits, carry out the shutdown procedures in Section IV above. If not, proceed directly to full power shutdown as listed below. 1) In the Electrical Equipment Room on the north side of Level 1, press the two red trip buttons for the S1 Transformer Feeder (feeds 4160VAC to the rotating building) and the S2 Transformer Feeder (feeds 4160VAC to the fixed building). This will shut off all the electrical power to the enclosure except for the main 25 kvac feed coming into the Electrical Equipment Room, and the UPS units, which will drain themselves in 10-15 minutes. The fire pump for the interior sprinkler system will still have power available as long as the utility building is distributing 25kVAC power to the site. Try to locate an authorized electrical personnel employee to do this for you. NOTE: THIS WILL DISABLE THE DIGITAL TELEPHONE SYSTEM FOR THE ENTIRE MGIO SITE. 12

Doc_info_start Title: LBTO Forest Fire Contingency Plan Document Type: Documentation Source: Steward Observatory Issued by: John Waack Date_of_Issue: 8 July 2003 Revised by: John Little Date_of_Revision: 16 April 2012 Checked by: John Little Date_of_Check: 20 April 2012 Accepted by: John Hill Date_of_Acceptance: 20 April 2012 Released by: Date_of_Release: File Type: MS Word Local Name: LBTO Forest Fire Contingency Plan Category: Overview General Sub-Category: Documentation Assembly: Safety Procedures Sub-Assembly: Part Name: CAN Designation: 004s001 Revision: b Doc_info_end 13