Thermal comfort investigation on a naturally ventilated two- storey residential house in Malaysia

Similar documents
Experimental performance evaluation of heat pump by using CO 2. as a refrigerant. IOP Conference Series: Materials Science and Engineering

Building Coverage Ratio at the Eastern Corridor of Jalan Ir. H. Djuanda Bandung

SRC: Smart Reminder Clock

Computer Simulation Investigation on the Effect of Channelled and Unchannelled Screens on Smoke Contamination in Atriums Upper Balconies

Experimental study of hybrid loop heat pipe using pump assistance for high heat flux system

The Research of Performance Comparison of Displacement and Mixing Ventilation System in Catering Kitchen *

Modeling of Ceiling Fan Based on Velocity Measurement for CFD Simulation of Airflow in Large Room

Capillary Tube and Thermostatic Expansion Valve Comparative Analysis in Water Chiller Air Conditioning

To investigate the surface properties for increasing efficiency of solar water heater

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

Modeling and Simulation of Axial Fan Using CFD Hemant Kumawat

Performance Study of Solar Heat Pipe with Different Working Fluids and Fill Ratios

Evaluation of moisture content in drying of grated coconut meat using grain moisture meter

Design Evolution: From Rolling Piston to Revolving Vane to Cross-Vane Expandercompressor

Numerical investigation on the effect of channelled and unchannelled screens on smoke contamination in atriums upper balconies with open upstand

Indoor Air of a Double-Storey Residential House in Malaysia

[Eswaran, 3(3): March, 2014] ISSN: Impact Factor: 1.852

Factors affecting quality of social interaction park in Jakarta

EXPERIMENTAL AND CFD STUDIES ON SURFACE CONDENSATION

Soil-roots Strength Performance of Extensive Green Roof by Using Axonopus Compressus

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Air Distribution and Ventilation Effectiveness in a room with Floor/Ceiling Heating and Mixing/Displacement Ventilation

Feasibility study on an energy-saving desiccant wheel system with CO 2 heat pump

Analysis of Evaporative Cooler and Tube in Tube Heat Exchanger in Intercooling of Gas Turbine

Enhancing the performance of the domestic refrigerator with hot gas injection to suction line

2. MODELLING OF HEAT EXCHANGER THROUGH CATIA

Properties of a two stage adiabatic demagnetization refrigerator

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland

Study of Hot-air Recirculation around Off-road Tier-4 Diesel Engine Unit Using CFD Abbreviations Keywords Abstract Introduction and Background

Evaluation of Slip Potentials on Bilecik Beige Marble with Pendulum Method

Aalborg Universitet. Diffuse Ceiling Inlet Systems and the Room Air Distribution Nielsen, Peter Vilhelm; Jensen, Rasmus Lund; Rong, Li

Thermal Analysis of Concentric Tube Heat Exchanger Using Louvered Strip Inserts

NUMERICAL STUDIES ON BARE CABIN FIRES WITH OPERATION OF SMOKE EXTRACTION SYSTEM

Heat transfer and heating rate of food stuffs in commercial shop ovens

MODELLING AND SIMULATION OF A ROOM WITH A RADIANT COOLING CEILING. Technicka 4, Prague 6, Czech Republic

A Numerical study of the Fire-extinguishing Performance of Water Mist in an Opening Machinery Space

Heat Transfer in Evacuated Tubular Solar Collectors

STACK EFFECT IN LIGHT WELL OF HIGH RISE APARTMENT BUILDING

POSSIBILITY TO USE SOLAR INDUCED VENTILATION STRATEGIES IN TROPICAL CONDITIONS BY COMPUTATIONAL FLUID DYNAMIC SIMULATION

Recent BRANZFIRE enhancements and validation

Sandeep V. Lutade 1, Krunal Mudafale 2, Ranjan Kishore Mallick 3 1, 2

Compression of Fins pipe and simple Heat pipe Using CFD

Performance Evaluation and Design Optimization of Refrigerated Display Cabinets Through Fluid Dynamic Analysis

AIRFLOW STUDY OF A SPILT-TYPE OUTDOOR UNIT SUBJECTED TO NEAR WALL EFFECT USING COMPUTATIONAL FLUID DYNAMIC (CFD) SIMULATION

The Development of Fire Risk Assessment Method for Heritage Building

Study of building typology of school constructed during the Dutch Colonial Period in Indonesia. Case study of Hoogere Burgerschool (HBS) in Bandung

Slipping properties of ceramic tiles / Quantification of slip resistance

Analysis of Causes of Defects Gloves and Bar Soap Using Failure Mode and Effect Analysis (FMEA) in XYZ Company

Faculty of Mechanical and Manufacturing Engineering Universiti Tun Hussein Onn Malaysia Pt. Raja, Batu Pahat, Johor, MALAYSIA

Passive fire building protection system evaluation (case study: millennium ict centre)

CFD Analysis of temperature dissipation from a hollow metallic pipe through circular fins using Ansys 14.5

Study of air circulation inside the oven by computational fluid dynamics.

Study on a novel variable capacity technology and control strategy for refrigerated shipping container unit

Improving Single-Sided Room Ventilation by Using a Ceiling Fan

Optimisation of cooling coil performance during operation stage for improved humidity control

Numerical study of heat pipe application in heat recovery systems

TRANSACTIONS ON ADVANCEMENTS IN SCIENCE AND TECHNOLOGY (TASTONLINE)

International Forum on Energy, Environment Science and Materials (IFEESM 2015)

A Study of Drying Uniformity in a New Design of Tray Dryer

INFLUENCE OF SOLAR RADIATION AND VENTILATION CONDITIONS ON HEAT BALANCE AND THERMAL COMFORT CONDITIONS IN LIVING-ROOMS

Basic CFD model of heat pipe

Mallikarjun 1, Anandkumar S Malipatil 2

The Performance of Diffuse Ceiling Inlet and other Room Air Distribution Systems Nielsen, Peter Vilhelm; Jakubowska, Ewa

CHAM Case Study Numerical Simulation of a Air-to-air Cross-flow Heat Exchanger

Effects of seawater flow rate and evaporation temperature on performance of Sherbet type ice making machine

VENTILATIVE COOLING CONTROL STRATEGIES APPLIED TO PASSIVE HOUSE IN ORDER TO AVOID INDOOR OVERHEATING

Investigation of Metal and Metal Oxide nanocoating on Fins in HPHE with Silver Water NanoFluid

Shuzo Murakami, Shinsuke Kato, and Taeyeon Kim Institute of Industrial Science, University of Tokyo Tokyo, Japan

HEAT TRANSFER COEFFICIENT ENHANCEMENT IN NATURAL CONVECTION FROM HORIZONTAL RECTANGULAR FIN ARRAYS WITH PERFORATIONS

PERFORMANCE OF EARTH TUBE HEAT EXCHANGER COOLING OF AIR A REVIEW

Residential ventilation concepts based on the idea of displacement airflow distribution

Study of Numerical Analysis on Smoke Exhaust Performance of Portable Smoke Exhaust Fan

1.1. SCOPE OF THE WORK:

Comparison Simulation between Ventilation and Recirculation of Solar Desiccant Cooling System by TRNSYS in Hot and Humid Area

Vertical Distribution of Air Temperatures in Heated Dwelling Rooms

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger

HOW TO REDUCE ENERGY CONSUMPTION OF BUILT-IN REFRIGERATORS?

Effect of Flow Distortion in Inlet Duct on the Performance of Centrifugal Blower

Heat transfer enhancement in an air process heater using semi-circular hollow baffles

NEW CD WARP CONTROL SYSTEM FOR THE CORRUGATING INDUSTRY

Stock Vessels for Improved Quality and Energy Savings

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress volume 9 Heiselberg, Per Kvols. Publication date: 2016

INDOOR CLIMATE IN HEATING CONDITION OF A LARGE GYMNASIUM WITH UNDER-FLOOR SUPPLY/RETURN SYSTEM

Effect Of Setup Thermostat Schedule On Heat Pump Water Heater Energy Consumption, Coefficient Of Performance And Peak Load

Improving Heating Performance of a MPS Heat Pump System With Consideration of Compressor Heating Effects in Heat Exchanger Design

HOT IN HERE: OFFICE OCCUPANT THERMAL COMFORT IN LAWRENCE HALL

Environment as a basis for the design of advertising structures by forming

Soil-Structure Interaction of a Piled Raft Foundation in Clay a 3D Numerical Study

Heat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling

Performance analysis of a vapour compression refrigeration system with a diffuser for theeco-friendly refrigerants R-134a, R-600a and R-152a

An application of the AHP in water resources management: a case study on urban drainage rehabilitation in Medan City

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

Improvement of Cibaduyut Housing District to Facing City Growth Phenomena, based on System Approach to Architecture Concept

Keywords: Triple tube heat exchanger (TTHE), hot water, cold water, CFD simulation.

Yan Xue 1 and Qingyan Chen 2,1* Abstract

power-saving period in summer, in which one of the indoor units was forced to change from a cooling mode to a fan mode, was introduced, and the effect

Experimental Comparison of Natural Convection Heat Transfer from a Blackened V-Fin Array

EXPERIMENTAL PERFORMANCE ANALYSIS OF SOLAR AIR HEATER WITH THREE DIFFERENT MODIFICATIONS IN ABSORBER PLATE

Specific Energy Consumption comparative study of Hot Air dryer and Heat Pump dryer for highland drying process Sayompon Srina

Transcription:

IOP Conference Series: Materials Science and Engineering PAPER OPEN ACCESS Thermal comfort investigation on a naturally ventilated two- storey residential house in Malaysia To cite this article: N A Malek et al 2015 IOP Conf. Ser.: Mater. Sci. Eng. 88 012014 Related content - Thermal characteristics of a residential house in a new township in Johor Bahru Y Y Lee, Y H Lee, S Mohammad et al. - Criteria of Architectural Composition Design in Residential Courtyards Aija Ziemeniece and Una le - Development of Residential SOFC Cogeneration System Takashi Ono, Itaru Miyachi, Minoru Suzuki et al. View the article online for updates and enhancements. This content was downloaded from IP address 148.251.232.83 on 20/06/2018 at 10:18

Thermal comfort investigation on a naturally ventilated twostorey residential house in Malaysia N A Malek 1, M H Khairuddin 1, M F Rosli Department of Mechanical Engineering, Universiti Tenaga Nasional, Jalan IKRAM-UNITEN, 43000 Kajang, Selangor, MALAYSIA E-mail: norhazwani@uniten.edu.my Abstract. This paper presents a case study to investigate the human thermal comfort on a naturally ventilated two-storey residential house in Malaysia. Three parameters were investigated in this study, namely the air temperature, air velocity and air humidity. These parameters were measured using the appropriate measuring device to obtain the actual data and compared with simulation results. The level of thermal comfort in the house was found to be poor as the parameters measured are over the limits specified by ASHRAE standards. Simulation on the model of the house was performed using the Computational Fluid Dynamics (CFD) commercial code, FLUENT to visualize the temperature distribution and air flow pattern and velocity in the house. The error between these two sets of data was acceptable and thus the simulation used in this study was validated. Comparison was also made in the CFD simulation to see the effects of using a ceiling fan installed in the house and without ceiling fan. The level of thermal comfort was poor in both cases as it did not satisfy the standards set by ASHRAE but more uniform temperature distribution inside the house was found when the ceiling fan was turned on. The thermal comfort level became critical in the afternoon as during this period, the house receives direct sunlight which causes the temperature inside the house to increase. Although the mechanical ventilation devices did not help to improve the thermal comfort in the house being studied, the CFD simulation results can be used by building designers to further improve the level of thermal comfort in naturally ventilated residential houses. 2 1. Introduction Due to Malaysian climate that is hot and humid throughout the year, the weather is not consistent and changing. High temperature with high humidity causes discomfort to the human and it affects the thermal comfort of the occupants in a house. Most residential buildings in Malaysia are not equipped with air-conditioning systems, but relies on natural ventilation, passive cooling system and mechanical ventilation devices such as ceiling and extractor fans to achieve certain level of thermal comfort. To optimize the thermal comfort effects, special attention must be given to the design and installation of these devices. Mechanical ventilation is more convenient compared to natural ventilation, but there is 1 2 Universiti Tenaga Nasional, Jalan IKRAM-UNITEN, 43000 Kajang, Selangor, MALAYSIA Nichicon (M) Sdn Bhd, No.4 Jln P/10, Kawasan Perusahaan Bangi, 43650, Selangor, MALAYSIA Content from this work may be used under the terms of the Creative Commons Attribution 3.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI. Published under licence by Ltd 1

a downside for it. As the mechanical ventilation consumes electricity, it is costly while natural ventilation is free. This study was conducted to investigate the thermal comfort of a naturally ventilated double-storey terrace house in Bangi, Selangor, Malaysia. The aim of this study is to investigate the house ventilation with the thermal comfort of the occupants in the house. Data measurements were taken and some parameters such as air temperature, air velocity and air humidity were studied. Simulation of the house using a CFD software, FLUENT was also done. When the results from each method were obtained and recorded, analysis of data was made by comparing these results together. The simulation was also done to compare the thermal comfort of the house with the fan turned on and off. All the results obtained were then compared with the standard set by the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) for human thermal comfort. On top of that, the objective of this study is also to find out the best improvement method to enhance the human thermal comfort. 2. Literature Review To assess the thermal comfort, it is necessary to determine the air velocity, temperature distribution, and relative humidity of the air in the residential building. Numerical methods such as computational fluid dynamics (CFD) can be utilized to assist in the analysis of thermal comfort. FLUENT is a useful tool that can be used to create a virtual model of the interior of the residential building and simulate air flow and temperature distribution which are directly related to thermal comfort. Many researchers have used CFD to analyze thermal comfort in building spaces and investigated the effects of natural and stratified ventilations on the thermal comfort. This includes Bastide et.al. [1], who has utilized CFD to predict building energy efficiency, Serra & Semiao [2] who evaluated and compared between two different ventilation strategies. Stravrakakis et.al. [3] also evaluated the effect of window sizes to thermal comfort and hygiene in buildings using CFD. Modifications to any existing residential building can also be simulated using CFD prior to any physical renovations. 3. Methodology 3.1 Actual Data Data collection and analysis were performed for the parameters investigated which are the air temperature, air velocity and air humidity. Standard values set by ASHRAE were compared with the data measured to determine the thermal comfort of the house occupants. The measurement of the parameters investigated was carried out when the house is ventilated naturally. The source of natural ventilation is from windows and doors which are open to allow the air from outside the house to enter the house and vice versa. The readings were taken periodically at 12am, 6am, 8am, 12pm, 2pm, 6pm, 8pm and 10pm for each day in two weeks. The measuring devices were placed in the hall, dining room, kitchen, master bedroom, room 1 and room 2. The air temperature was measured using anemometer and hygrometer. 3.2 CFD Simulation The simulation was performed using CFD software, FLUENT for house with natural ventilation and fan turned off and when the fan is turned on. The house was drawn and meshed using Gambit software and analyzed using FLUENT to investigate the behaviour of the air temperature and air velocity inside the house. The software was unable to simulate the air humidity. Thus, only air temperature and air velocity were simulated and investigated in both simulations. The boundary conditions were set the same with the value measured during the data collection. Other physical values were also measured such as the wall temperature, glass temperature, velocity inlet (wind speed), size of openings (window and door) and other. Some parts of the house were neglected as it does not affect the parameters investigated. Figures 1 (a) and (b) show the floor plan with dimension for ground floor and first floor. 2

Figure 1. (a) Ground Floor Plan (b) First Floor Plan The measured physical value used in the simulation is the opening and fan dimensions. The openings are windows and doors, which is the source of natural ventilation. The dimensions of doors, windows and fans were considered to be standard in size for all residential houses in Malaysia. The dimension of the fan is described as span. Span means the diameter of the fan or the distance between one ends of the fan to another end. 52 span of fan was chosen as it is in standard size that applicable for all room dimensions. This size is usually used for standard bedroom and dining room [4]. Table 1 shows the boundary conditions set in the simulation. The velocity inlet is the front door which is the source of the natural ventilation and the back door is the pressure outlet for the air to flow out which is shown in Figure 2. Wall will be set by default automatically for faces that are not set with boundary condition. Table 1. Boundary Conditions Boundary Condition/ Wall Thickness Wall Temperature Air Velocity (v), Air Temperature Characteristic (t), m (T w ), K m/s (T a ), K Outer Wall 0.125 303 N/A N/A Inner Wall 0.125 300 N/A N/A Glass Sliding Door 0.005 303 N/A N/A Velocity Inlet N/A N/A 0.2 300 Fan N/A N/A 12.7 300 Pressure Outlet N/A N/A N/A N/A 3

Figure 2. Gambit House Drawing with Boundary Condition 4. Results, Analysis and Discussions After the simulation data was obtained, validation of the data was performed with the actual data. Comparisons were made in both cases and represented in Figure 3 (a) and (b). The percentage error for air temperature and air velocity is 0.24% and 13.11% respectively. These errors are acceptable and thus the simulation results are valid and acceptable. Figure 3. Data Comparisons for: (a) Air Temperature and (b) Air Velocity The velocity vector of the internal house was obtained to investigate the pattern of air flow inside the house with the fan turned on and off (see Figure 4 (a) and (b)). When there is only natural ventilation, the air flow is only existed on the ground floor because at the ground floor, there is a source of natural ventilation which is the front door. The back door which acts as the outlet for the wind flow also helps in encouraging the air flow at the ground floor. Small or no air flow at the first floor cause the temperature distribution at the first floor for the case of fan off is higher compared to temperature distribution for case of fan turned on. From the results obtained, it shows that the natural ventilation only exists on the ground floor because the source of the wind is located at the hall and the outlet is at the kitchen. The air velocity at the first floor is approximately zero. The results for both actual and simulations were then compared in a graph together with the ASHRAE set of standards in Figure 5. As the velocity for the actual and simulation when the fan turned off are almost the same, both values are overlapped in the graph. Due to the very small value, the graph plotted for the velocity when fan turned off shows straight line near to zero. The velocity is below the limit set by the ASHRAE. When the fan is turned on, the magnitude of velocity is very large and exceeds the limit set by ASHRAE. With the presence of mechanical ventilation, the temperature distribution of the house is able to be regulated and maintained. 4

Figure 4. Velocity Vector of the House (a) When Fan Turned Off (b) When Fan Turned On Figure 5. Comparison of Average Air Velocity for All Cases The heat absorbed by the wall is one of the factors that cause the temperature inside the house to increase. With natural ventilation available at the ground floor, the temperature distribution inside the house is maintained to 302 K compared to the temperature of the wall which is 303 K (see Figures 6 (a) and (b)). Figure 6. Temperature Contour (a) Fan Turned Off (left) (b) Fan Turned On (right) Some part of the house at the first floor has temperature of 303 K, which is almost the same with the wall temperature. This causes discomfort to the occupant due to the high temperature. The results obtained show that mechanical ventilation which is the fan, helps a lot in maintaining the temperature distribution inside the house. The results for both actual and simulations were then compared in a 5

graph together with the ASHRAE set of standards in Figure 7. It is shown in the figure that the air temperature for case when fan is turned on is close to the ASHRAE standard, while the other results are farther away from the ASHRAE standard. Natural ventilation is not enough to maintain the temperature as it is changing throughout the time and not consistence. Figure 7. Comparison of Average Air Temperature for All Cases 5. Conclusion As conclusions, the thermal comfort of the house is generally poor and does not satisfy the standards set by ASHRAE. However, the level of thermal comfort for the house with fan turned on is considered good compared to that of with fan turned off. Both cases show that the thermal comfort level becomes critical during afternoon as during this period, the house receives direct sunlight which causes the temperature inside the house to increase. With the fan turned on, the temperature inside the house is able to be maintained and regulated. Improvement is needed in order to achieve the thermal comfort. For air velocity, mechanical ventilation such as fan can be used to encourage the air flow inside the house. As the house design is fixed and house modification is restricted, other improvement should be considered for example, installing the latest mechanical ventilation system that is more effective and energy saving. Glass doors and windows are tinted with protective film to block direct sunlight from penetrating the house. Planting shade trees is also another method in reducing the direct sunlight and reduce the temperature distribution around the house. Others opening available such as small windows can be opened to encourage natural ventilation flowing from outside to inside house. 6. References [1] P. L. F. G. a. H. B. A. Bastide, "Building energy efficiency and thermal comfort in tropical climates," Presentation of a numerical approach for predicting the percentage of well-ventilated living spaces in buildings using natural ventilation, vol. 38, pp. 1093-1103, 2006. [2] A. V. S. N. Serra, "Comparing displacement ventilation and mixing ventilation as HVAC strategies through CFD," Engineering Computation: International Journal for Computer-Aided Engineering and Software, vol. 26, no. 8, pp. 950-971, 2009. [3] D. K. P. Z. H. S. N. M. G.M. Stavrakakis, "Selection of window sizes for optimizing occupational comfort and hygiene based on computational fluid dynamics and neural networks," Building and Environment, vol. 46, pp. 298-314, 2011. [4] D. Mar, "What Size Ceiling Fan Do I Need?," 2013. [Online]. Available: http://www.delmarfans.com/educate/basics/what-size-ceiling-fan-do-i-need/. [Accessed 8 November 2013]. 6