Victoreen Primalert 35 Area Radiation Monitor

Similar documents
Nuclear Associates

Nuclear Associates

Dual-Diode Dosimeter Patient Dose Monitor

Victoreen & 660-8

Area Monitor/Frisker Count Rate Meter Victoreen

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

MODEL 8144-RD CLOCK SELECTOR/DISTRIBUTION AMPLIFIER INSTRUCTION MANUAL. SPECTRACOM CORPORATION 95 Methodist Hill Drive, Suite 500 Rochester, NY 14623

Victoreen. Operator Manual. Current Mode Beta Scintillation Detector, Model

AM-806. Waste/Door Radiation Monitor OPERATIONS MANUAL

Global Water Instrumentation, Inc.

MST, INC. MODEL 2002 CARBON MONOXIDE MONITOR OWNER S MANUAL

Installation, Operation, and Maintenance Instruction Manual

MODEL 5800A CARBON MONOXIDE (CO) MONITOR AND ALARM SAMPLE-DRAWING TYPE

MST, INC. MODEL 2002 CARBON MONOXIDE MONITOR (AMBIENT-TYPE) OWNER S MANUAL

Replaced by A5367CA. DISCONTINUED PRODUCT SMOKE DETECTOR WITH INTERCONNECT AND TIMER FEATURES

275HVD NON-CONTACT, HIGH VOLTAGE DETECTOR DETECTOR DE ALTA TENSIÓN SIN CONTACTO

MST, INC. MODEL 2002 OXYGEN MONITOR (AMBIENT-TYPE) OWNER S MANUAL

DISCONTINUED PRODUCT. For reference only SMOKE DETECTOR WITH INTERCONNECT FEATURES. ABSOLUTE MAXIMUM RATINGS (Voltages are referenced to V SS

D-TEK Select. Refrigerant Leak Detector

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL AH1000, BH1000, AND EH1000 SERIES ANNUNCIATORS

TECHNICAL DATA. Wet 26a. February 22, 2009

RLD-H10P Refrigerant Leak Detector

www. ElectricalPartManuals. com GADD MKIII Ground Fault Indication System Instruction Manual Ground Fault Protection

Model AV1LED Audio-Visual LED Light Installation and Maintenance Manual

PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System

DETCON MODEL SW-AV1-DV2 Hazardous Duty Class I. Div 2, Multi-tone Alarm Station

LUDLUM MODEL AND LUDLUM MODEL ALPHA, BETA, & GAMMA DETECTORS

Installation Instruction. Puritan Bennett. Wall Air Water Trap For 800 Series Ventilator Basic Cart. Pla

Wiring Instructions. Single Doors 99 Checkmate Series Use one or Master Unit each door or one or Support unit each door

DETCON MODEL SW-AV2-DV2 Hazardous Duty Class I. Div 2, Multi-tone Alarm Station

Technical Manual. VFD / Cabinet Heater Upgrade 110 VAC Heater to 12 VDC Heater. Provided by: Chart Inc.

RCR-REX Request-to-Exit Dual Technology Motion Sensor Installation Guide

DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL G1000 AND H1000 SERIES ANNUNCIATORS

MODEL A-316 CARBON MONOXIDE (CO) MONITOR AND ALARM FOR COMPRESSED AIR TESTING

GasScanner 8C. Eight Channel Monitor. Operator s Manual. MINT-0281-XX Rev. A 01/29/08

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

Installing the Cisco ONS FAP-4 Fuse Alarm Panel

Instruction Manual. for. Soldering / SMD Rework Station. For Lead-free soldering application and rework on professional SMD electronics.

WHIRLPOOL AUSTRALASIA CONSUMER SERVICES

Cautions and Warnings. Introduction 4009 NAC POWER EXTENDER

Installation Instructions

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX

CAR BURGLAR ALARM K3504

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

Victoreen 942A-200. Operators Manual. Universal Digital Ratemeter

LUDLUM MODEL 44-9 ALPHA, BETA, GAMMA DETECTOR. February 2010 Serial Number PR and Succeeding Serial Numbers

ATOMLAB XENON TRAP MONITOR OPERATION AND INSTALLATION MANUAL FN: /12

Water Detection Controllers

CARSON MANUFACTURING CO., INC NORTH RURAL STREET INDIANAPOLIS, IN (888) TECHNICAL BULLETIN

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

RAM GENE / RAM GENE-1

INDICATOR LAMPS & LED REPLACEMENT LAMPS

LUDLUM MODEL ALPHA, BETA, GAMMA HAND DETECTOR. June 2016 Serial Number and Succeeding Serial Numbers

Dogeroo & Super Dogeroo

LUDLUM MODEL 44-3 LOW ENERGY GAMMA SCINTILLATOR. May 2018 Serial Number PR and Succeeding Serial Numbers

BX444-Mc Gas Detector

SERVICE MANUAL VC3ED FULL SIZE ELECTRIC CONVECTION OVEN - NOTICE -

Reliance DuraStar ATEX HAZARDOUS LOCATION INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS

Alarm Tone Generator Model AG17

Advanced Test Equipment Rentals ATEC (2832) LS-1310/1550 Laser Source. Service Information Sheet.

OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL

DensityPRO+ Gamma Density System with Remote Transmitter Installation Guide P/N Part of Thermo Fisher Scientific.

LUDLUM MODEL 44-2 GAMMA SCINTILLATOR. February 2018 Serial Number PR and Succeeding Serial Numbers

GAS MONITOR Model Model

Instruction Manual E4 ChamberIR Heater

SAFETY PERSONAL AC VOLTAGE (50 or 60Hz) PROXIMITY DETECTOR

DH100ACDCLP Air Duct Smoke Detector with Extended Air Speed Range

MODEL 23 AND 23-1 ELECTRONIC PERSONAL DOSIMETER. August 2017

Instruction Manual CHLORALERT TM Series T17CA4000 Chlorine Gas Leak Detector CAPITAL CONTROLS

Part Number Structure ZT 028 L D CT R 15

STATUS ALARM HISTORY ALARM RESET

HALOGUARD IR MULTI-POINT, COMPOUND SPECIFIC MONITOR INSTRUCTION MANUAL

Cold Door 2 LED Retrofit Kit Lighting System

TECHNICAL INFORMATION Touchtronic Clothes Dryers

Single Doors FIREGUARD Series Use one Master Unit each door or one 2409 Support unit each door. Pairs of Doors

OPERATION & INSTALLATION MANUAL FOR ALARM PANEL M2AP01

Wiring Instructions (01-09)

PORTABLE or FIXED PERSONNEL & VEHICLE MONITOR

8600 EMR SERIES. INSPK NO Rev.06/ INS NO. GENERAL DESCRIPTION

MVP-D-TEK Vehicle Loop Detector 9 Volts DC to 240 Volts AC. Operating Instructions

A5364. Ionization Smoke Detector with Interconnect

PO Box 827 Hawley, MN (218) Fax (218)

Helicycle Crew Alerting System (CAS)

RAM3 Remote Alarm Module

DSGH. Radiation-Based Detector with GEN2000 Electronics for Density Measurement QUICK REFERENCE GUIDE

6 Oz. Twin Pop. Popcorn Machine Instruction Manual Model #2666EX. Cincinnati, OH USA. Part No EX Revised June 1996

Design Manual Installation Operation Maintenance

MetRad1 Handheld Metal/Gamma Detection Unit. Operation Manual. Berkeley Nucleonics Test, Measurement and Nuclear Instrumentation since 1963 BNC

TRN100BPT, TRN100BP, and TRN100BPC Air Duct Smoke Detector with Extended Air Speed Range

Isco 3700ZR Sampler. Manual Set

1126 Series Ceiling Mount PIR Motion Detector

Model 6495 Freezing Rain Sensor. User's Manual. All Weather Inc National Drive Sacramento, CA USA

TECHNICAL DATA OBSOLETE

MODEL KP-200 VANDAL RESISTANT & WEATHERPROOF FLUSH MOUNT DIGITAL KEYPAD DESIGNED FOR ACCESS CONTROL APPLICATIONS

E-PDD Duct Smoke Detector Installation Sheet

Model 8730 INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS. Outdoor Shower and Eyewash System General Area Classification & Class I Division 2

Caliber Series LED Edgelit Exit Sign EXPORT AC Only or Emergency Operation READ AND FOLLOW ALL SAFETY INSTRUCTIONS

TS93 EMR WITH SMOKE DETECTOR

LED CLOCK with SLOW ON DIMMER. Total solder points: 120 Difficulty level: beginner advanced K8091EU ILLUSTRATED ASSEMBLY MANUAL

Transcription:

Victoreen 05-437 Primalert 35 Area Radiation Monitor Operators Manual March 2005 Manual No. 126011 Rev. 3 2003, 2005 Fluke Corporation, All rights reserved. Printed in U.S.A. All product names are trademarks of their respective companies

Fluke Biomedical Radiation Management Services 6045 Cochran Road Cleveland, Ohio 44139 440.498.2564 www.flukebiomedical.com/rms

Table of Contents Section 1: Introduction... 1-1 1.1 Product Description... 1-1 1.2 Specifications... 1-2 Section 2: Getting Started... 2-1 2.1 Receiving Inspection... 2-1 2.2 Mounting... 2-1 2.3 Power... 2-1 2.4 Optional Power... 2-2 2.5 Routine Cleaning... 2-2 2.6 Attaching a Ground Wire... 2-2 Section 3: Operation... 3-1 3.1 Set up... 3-1 3.2 Testing... 3-1 3.3 Setting the Alarm Level... 3-1 3.4 Alarm Reset... 3-1 Section 4: Maintenance... 4-1 4.1 Maintenance... 4-1 i

(Blank page)

Introduction Product Description 1 Section 1 Introduction 1.1 Product Description The Primalert 35 Area Radiation Monitor provides reliable, continuous monitoring of radioactive materials. Six front panel, color-coded LED's (1, 2, 4, 8,16, and 32 mr/h) indicate an increase or decrease in radiation level. The LED for each level lights as the radiation reaches that level and goes out as the radiation drops below that level. Visual and aural alarms are user-set to activate at anyone of the six levels via a front-panel screwdriveradjustable control. When the preset level is exceeded, bright flashing red lights (visible over a 1800 field) and a loud intermittent signal are activated. The alarms stop automatically when the radiation level falls below the preset value. The aural alarm indicators may be selected/deselected via a front panel switch. Fail-safe operation is assured by continuous visual (front panel LED) indication of background radiation. The unit is designed not to jam or indicate false readings at high radiation levels. The Primalert 35 includes a jack to allow attachment of an optional Primalarm (Model 05-434) at a remote location up to 100 feet from the main unit. The Primalarm provides both audible and visual warnings. Figure 1-1 Primalert 35 Area Radiation Monitor 1-1

Victoreen 05-437 Operators Manual 1.2 Specifications Detector Energy Dependence Overload Protection Operation Indicator Range/lndicators Energy-compensated G-M tube 10% to 40% from 50 KeV to 2 MeV, as referenced to 137 Cs Alarms in fields higher than 100 R/h when detector is completely blocked for pulse operation. Provide continuous visual indication of background radiation. 1 mr/h: Green 2 mr/h: Green 4 mr/h: Yellow 8 mr/h: Yellow 16 mr/h: Red 32 mr/h: Red Response Time Level Response Time 1 mr/h 3 seconds 2 mr/h 1.5 seconds 4 mr/h 800 milliseconds 8 mr/h 400 milliseconds 16 mr/h 200 milliseconds 32 mr/h 100 milliseconds Alarms Alarm may be preset by user at any indicated discrete level by means of the front panel selector switch; front panel switch selects all alarms or visual only. Visual Alarm: bright incandescent red lamps flashing on/off approximately 1/sec. Aural Alarm: 400 Hz tone, alternating 1/sec; sound level = 76 db at one foot. Operating Conditions 10 C to 40 C (50 F to 104 F) Maximum of 90% relative humidity (non-condensing) External Connectors Jack located on case bottom allows attachment of external aural/visual alarm (Primalarm) at remote location. Power Supply Part 14-314 (United States, Canada) Input 117 VAC, 60 Hz, 12 W Output 12 VDC, 500 ma Part 14-400 (Europe) Input 230 VAC, 50 Hz, Output 12 VDC, 500 ma Part 14-417 (United Kingdom) 1-2

Introduction Specifications 1 Input 230 VAC, 50 Hz, 13.8 W Output 12 VDC, 580 ma Part 14-417, Part 14-416 (Australia) Dimensions Accessories Supplied 5.9 in. high x 3.4 in. wide x 13 in thick Unit clips to wall with removable mounting clip. Appropriate 115V (230) CE approved converter P/N 102007: Wall Mounting Bracket P/N 74: Spare Lamp Available: P/N 05-441: PrimaPak II Backup Battery Pack P/N 05-434: Primalarm Remote Alarm unit. P/N 62-103: Check-source, 137 Cs, 10 μci, License Exempt 1-3

Victoreen 05-437 Operators Manual (Blank page)

Getting Started Receiving Inspection 2 Section 2 Getting Started 2.1 Receiving Inspection Upon receipt of the unit: 1. Inspect the carton(s) and contents for damage. If damage is evident, file a claim with the carrier and notify Fluke Biomedical, Radiation Management Services at 440.248.9300. 2. Remove the contents from the packing material. 3. Verify that all items listed on the packing list have been received and are in good condition. 2.2 Mounting NOTE If any of the listed items are missing or damaged, notify Fluke Biomedical. The mounting bracket supplied (P/N 102007) may be attached to any convenient vertical mounting surface. Before mounting the bracket to the wall, however, make sure that the 6 ft. converter power cord will reach the nearest power outlet. The wall-mounting bracket comes supplied with double-sided foam tape already attached. Just peel off the protective paper covering and firmly apply to the mounting surface. CAUTION 2.3 Power Once in place the bracket cannot be moved or removed without destroying the tape. Make sure of your installation site before applying. The plug on the end of the converter power cord should first be inserted into the larger jack on the bottom of the Primalert. The converter should then be plugged into the wall outlet. Note that when first connected to power, the Primalert may alarm for as long as three seconds before the automatic reset is actuated. 2-1

Victoreen 05-437 Operators Manual 2.4 Optional Power The Primapak II storage battery supplies a source of 12-16 Volt DC power to the Primalert using the converter plug connection. The plug is a Switchcraft #760, or equivalent, with the sleeve negative and pin positive. The current drain at background radiation levels is about 25 ma, and about 250 ma at full alarm levels. The optional Primapak II Back-up Battery Pack, Model No. 05-441, is available as an optional power source for the Primalert. The Primapak II consists of rechargeable gel cells and circuitry that switches the Primalert to battery operation if line power is lost. When AC power is present, the battery is automatically recharged. Fully charged cells provide approximately eight hours of operation under alarm conditions or more than 32 hours of operation. The Primapak II includes a 120VAC/16VAC converter and interconnect cable. 2.5 Routine Cleaning Do not immerse the Model 05-437 Primalert. The unit is not waterproof. Liquid could damage the circuits. The unit should be kept clean and free from dirt and contamination. The unit may be cleaned by wiping with a damp cloth using any commercially available cleaning or decontaminating agent. 2.6 Attaching a Ground Wire If required, use the following procedure to attach a separate ground wire to the instrument: 1. Loosen the screw in the center of the back cover. 2. Remove the back cover. 3. Attach a wire to the ground terminal by running it up through the small hole between the jacks. At least #16 gauge wire should be used for this purpose. 4. Replace and secure the back cover. CAUTION NOTE 2-2

Operation Set Up 3 Section 3 Operation 3.1 Set Up The only set-up required for the Primalarm is the attachment of one end of the power cord (converter) to the unit and the other end into a properly grounded AC outlet as noted in Section 2. When power is first applied to the unit, the alarm and one or more of the LED's may light. After a maximum of three seconds, the indicators will extinguish and the alarm will reset. The unit should now be operational with the OPERATION INDICATOR LED flashing on or off with each background pulse received. The Primalert 35 is a fully digital preset count instrument. The measurement and reset time are dependent on count rate. Refer to the response time specifications listed in Section 2. 3.2 Testing Test the unit for proper operation by positioning the check source (P/N 62-103) as indicated on the front panel. With the check source label down, the Primalert 35 should indicate between 2 and 8 mr/h; with the label up, it should indicate between 1 and 4 mr/h. 3.3 Setting the Alarm Level The Alarm Level may be set with a small screwdriver from the front panel. Alarm levels from 1 to 32 mr/h may be set. When the radiation exceeds the setting, the alarm will be actuated. 3.4 Alarm Reset The alarm reset on the Primalert 35 is automatic and both aural and visual alarms will stop when the radiation level drops below the Alarm Level setting. 3-1

Victoreen 05-437 Operators Manual (Blank page)

Maintenance Maintenance 4 Section 4 Maintenance 4.1 Maintenance WARNING This instrument contains CMOS integrated circuits. No service should ever be attempted unless by a qualified service technician thoroughly familiar with these devices. Static charges normally present in a dry atmosphere or leakage current in soldering irons or other non-grounded tools can instantly destroy CMOS integrated devices. If this device has I.C. sockets, do not even attempt to remove or replace them. WARNING Failure to conduct periodic performance test in accordance with ANSI N323.1978, Paragraphs 4.6 and 5.4, and to keep records thereof in accordance with Paragraph 4.5 of the same standard, could result in erroneous readings or potential danger. ANSI N323.1978 becomes, by this reference, a part of this document. An assembly drawing (Figure 4-1), schematic diagram (Figure 4-2), PC board component layout (Figure 4-3), and applicable parts lists (Tables 4-1 and 4-2) are provided for the user's reference. Table 4-1. Main Assembly (126028) Parts List Item No. Part No. Description Qty 5 126021 PC B Assembly 1 6 126026 Panel 1 7 126027 Case 1 8 102009 Reflector 1 9 102008 Lens 1 12 500002 SPDT Switch 1 14 0960008 Parker 2-006 O-ring 1 16 5-1078 Screw, 5-20 XI 1 17 5-99 Screw, 1-72 x 3/16 2 18 5-26 Screw, 4 x.25 3 4-1

Victoreen 05-437 Operators Manual Table 4-2. PC Board Assembly (126021) Parts List Item No. Ref. No. Part No. Description Qty 6 V1 010054 Tube Shield Assembly 1 7 U1, 4 630001 IC, Quad Nor Gate, 4001 UB 2 8 U7 630002 IC, Quad Nand Gate, 4011 UB 1 9 U5, 6 630006 IC, Quad Latch, 4043B 2 10 U2, 3 630008 IC, 12 Stage Counter, 4040BE 2 12 D1 600005 Diode 1N5243B 1 13 D2, 3,4 600001 Diode 1N4006RL 3 14 D5, 6 600003 Diode1N414B 2 15 Q1, 2 620001 Transistor 2N4124 2 16 Q4-9 620003 Transistor, S.C.R. MCR-103 6 17 Q11, 12 620003 Transistor, MPS-A13 2 18 11,2 680009 REDT-1 Hi-Intensity LED 2 19 13,4 680008 Yellow T-1 LED 2 20 15-7 680007 Green T-1 LED 3 23 A1 710002 12 VDC Audio Alarm 1 24 U8 640001 IC, +6 V Regulator, 78M06 1 25 5-196 Screw, PH, 4-40 x.38 1 26 5-764 Washer, INT, 4, s, CP 1 27 5-850 Nut, Hex, 4-40, 5, CP 1 28 0911403 Screw, BH, 6-32 x.25, 5 1 29 5-766 Washer, INT, 6, 5, CP 1 30 0976002 Binding Post, 6-32 PCB MNT 1 31 110-11 780006 Lamp Holder, T-1 3/4 PCB MNT 2 32 110-11 680010 Lamp, T-1, 3/414 V @ 1A, #74 2 33 T1 780013 Microphone Jack 1 34 A1 780014 Power Jack 1 35 C1 212221 Cap, Film, 2200 PF, 250 V, 10% 1 36 C8, 14,16, 17 211031 Cap, Film,.01 μf, 250 V, 10% 4 37 C13, 15,23 211032 Cap,.01 μf, 100 V, 20% 3 38 C5, 7,20 211041 Cap, Film,.1 μf, 160 V, 10% 3 39 C6, 22 232252 Cap, Tant, 2.2 μf, 16 VDC, 20% 2 40 C9, 10,11 201031 Cap,.01 μf, 1000 V, 20% 3 41 C21 214741 Cap, Film,.47 μf, 100 VDC, 10% 1 42 C3, 4 201021 Cap, 1000 PF, 500 V, 20% 1 45 R2, 5-10,37 Resistor, Film, 510k,.25W, 185-1434 5% 8 4-2

Maintenance Maintenance 4 46 R22, 23 302041 Resistor, Film, 200k,.25W, 5% 2 47 R20, 26,30, Resistor, Film, 100k,.25W, 341041 32,33,38, 5% 6 49 R27, 29,31, 34,40 341032 Resistor, Film, 10k,.25W, 5% 5 50 R13-18, 28 185-1448 Resistor, Film, 200,.25W, 5% 7 51 R24 185-2496 Resistor, Film, 2k,.25W, 5% 1 52 R25, 41 342031 Resistor, Film, 20k,.25W, 5% 2 53 R21, 39 303351 Resistor, Film, 3.3m,.25W, 5% 2 54 R3 391052 Trim Pot, 1M,.5w, 20%, Open 1 55 R36 300501 Resistor, Film, 5.1,.25W, 5% 1 57 T1 700003 Transformer, H.V., OSC 1 58 S1 560009 Switch, Rotary, 6-pos, 1 59 44-16 Washer, Flat,.25 ID/.41 OD 1 60 33-139- 16 Socket, 16-Pin IC, PCB MNT 4 61 33-139- 14 Socket, 14-Pin IC, PCB MNT 3 63 0998002 Double-sided Tape, 3/4 x 1 1/16 1RL 4-3

Victoreen 05-437 Operators Manual Figure 4-1 Primalert 35 Assembly (126028) 4-4

Maintenance Maintenance 4 Figure 4-2 Primalert 35 Schematic (126015) 4-5

Victoreen 05-437 Operators Manual Figure 4-3 PC Assembly (126021) 4-6

Fluke Biomedical Radiation Management Services 6045 Cochran Road Cleveland, Ohio 44139 440.498.2564 www.flukebiomedical.com/rms