Models: HES-20S, HES-20M HES-30S, HES-30M HES-40S, HES-40M Tube-Ice Machines

Similar documents
Vogt Tube - Ice machines P34AL

Installation Instructions

Turbo Chiller Now in Stock "Click Here" for details. (1 of 2)8/12/ :01:18 AM

P-24A & P-34A TUBE-ICE MACHINE

HE S Series TUBE-ICE MACHINE INSTALLATION & START-UP INSTRUCTIONS. Part Number: 12A4171S0702

P-34F TUBE-ICE MACHINE

Glass Doors, Hinged Bottom Mounts

Hoshizaki America, Inc.

Hoshizaki America, Inc.

F-2000MLF(-C) F-2000MWF(-C) F-2000MRF(-C) F-2000MRF3(-C)

Precise Temperature Control; Compact Footprint

Hoshizaki America, Inc.

MHG-LR MODULAR TURBO REFRIGERATING ICE MACHINE

MAC-120HE-03 Air-Cooled Chiller

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

05TA TUBE-ICE MACHINE

C13-Series Engineering Guide

Hoshizaki America, Inc.

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

10TA TUBE-ICE MACHINE

Hoshizaki America, Inc.

IMPORTANT. HOSHIZAKI provides this manual primarily to assist qualified service technicians in the service and maintenance of the icemaker.

HE S Series TUBE-ICE MACHINE. Service Manual $50 00

Installation Instructions. Revision Date: 05/16/12

Reciprocating Simplex and Duplex Tank Mount Compressor Systems Rev. 08/23/12

Reach In Refrigerators Bottom Mount

Hoshizaki America, Inc.

MAC N-407 Air-Cooled Chiller

Air-Cooled Condenser. Installation Instructions. Revision Date: 12/21/98

Plate Water Heaters Brazed Plate Water Heaters-BPH Series Plate and Frame Water Heaters-PFH Series

KM-630MAH KM-630MWH KM-630MRH

KM-61BAH KM-101BAH KM-151BAH

RHP120 RHP300 Steam Boiler Series

Hoshizaki America, Inc.

MACH N-407 Heat Pump Air-Cooled Chiller

Hoshizaki America, Inc.

water to water heat pumps

Refrigerated Air Dryers

Hoshizaki America, Inc.

Reliability is a beautiful thing TM MODULAR CRESCENT CUBER KM-500MAH KM-500MWH KM-500MRH SERVICE MANUAL

Suggested Specifications Prestige Excellence 110

Hoshizaki America, Inc.

Hoshizaki America, Inc.

Laboratory Open Scroll Air Compressor System with Premium NFPA Controls Rev. 06/27/14

FLAKER/DCM SEQUENCE OF OPERATION

Central Chillers TS Series

Hoshizaki America, Inc.

PARAGON Commercial Refrigeration Controls

Liebert CSU3000 Chiller

Hoshizaki America, Inc.

Maestro Plus. Features. self-contained 425 series Chewblet RIDE ice machine

Product Specifications. Vertical Floor Consoles By First Co.

Horizon Elite Ice Machine Installation Instructions for Remote Condensing Unit

1025, BOUL. MARCEL-LAURIN INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER. Prepared par Claude Gadoury, P. Eng MTL TECHNOLOGIES INC.

next generation R 1 cycling refrigerated compressed air dryers flow capacity: scfm ( Nm 3 /hr)

Laboratory Open Scroll Air Compressor System with Premium NFPA Controls

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

Maestro Plus. Features. self-contained C/E 425 series Chewblet RIDE ice machine

F o r Te x t i l e I n d u s t r y

Hoshizaki America, Inc.

Stainless Steel Indirect Water Heaters

RACK-MOUNT Air Conditioners

MHG A FL MODULAR. Manual Part Number 12A4171M11. Service Manual $50.00 USD

Submittal Data GA Line AYF Series Commercial and Specialty Chiller-Heaters 2 or 4 pipe Gas Fired Absorption Chiller-Heater Cooling and Heating

FT900BD FLIGHT-TYPE DISHWASHER

Vent-Rite. Cast Iron And Steel Receivers. Simplex, Duplex, Triplex And Quadruplex Units. Pump Capacities To 150 GPM. Discharge Pressure To 75 PSI

Cleveland Range Inc. COMBINATION COOK TANK, CHILLER & SOUS VIDE PRODUCTION UNIT. Cleveland General Specifications. Cleveland Standard Features

LOW PROFILE UNIT COOLER

PAJ3. Product Specifications

Product Data. Features/Benefits. GEMINI 38AKS Commercial Air-Cooled Split Systems 50/60 Hz. 25 to 40 Nominal Tons (82.8 to 127.

Hoshizaki America, Inc.

HX Series. Compressed Air Dryers 10 to 2400 scfm. Setting a new standard in Quality and Reliability DRYMAX DRYMAX DRYMAX

Energy Use in Refrigeration Systems

OACS Outdoor Air-Cooled Central Chillers

Hoshizaki America, Inc.

MH1WC4W-06-1-B Chilled/Hot Water 1-Way Cassette Fan Coil

Hoshizaki America, Inc.

JCseries EVAPORATIVE CONDENSER. engineering data

Service Manual. Modular Crescent Cuber Serenity Series Model KMS-2000MLH. Including Condensing Unit Models SRK-20H/3. hoshizakiamerica.

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCFC4W Chilled/Hot Water Cassette Fan Coil

MHCFC4W Chilled/Hot Water Cassette Fan Coil

MHCFC4W Chilled/Hot Water Cassette Fan Coil

CHC Series High Capacity Refrigerated Dryer 2,000 20,000 SCFM

FT900SDBD DUAL RINSE FLIGHT-TYPE DISHWASHER

INSTALLATION and OPERATION INSTRUCTIONS

How Does an Evaporative Cooler Work?

Refrigerated Air Dryers

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

CHILLER. Operator s & Installation Manual

Horizon Elite Ice Machine Installation Instructions for Remote Condensing Unit

USER S MANUAL HSC-14/18/24/24A

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)

DCM-500BAF DCM-500BWF DCM-750BAF DCM-750BWF

HOSHIZAKI CUBELET ICE DISPENSER MODEL DCM-240BAF SERVICE MANUAL

LOW PROFILE UNIT COOLER

Hoshizaki America, Inc.

Super-Flo Low Profile Unit Cooler

BLOOD PLASMA Walk-in Freezers

SpaceKeeper Console (SKC)

Transcription:

Models: HES-20S, HES-20M HES-30S, HES-30M HES-40S, HES-40M Tube- Machines Standard Construction: All surfaces in contact with water or ice are of stainless steel or other rust resistant material. External finish is available in heavy-duty ABS panels or stainless seel panels. Units are factory tested and adjusted for cylinder ice and can be manually switched to crushed ice in the field if required. Unit can be set for crushed ice at factory at no extra charge if specified on order. Electrical Requirements: Standard is 208/230V, 3ph, 60hz. Other configurations are available on request including 50hz. Dual Selector Switch (Optional): The selector switch has three settings: 1. Cylinder (Tube-) only 2. Crushed only 3. Both cylinder and crushed ice for split bins Tube- Evaporator and Refrigerant Receiver: Manufactured in accordance with the A.S.M.E. Code with a 25-year warranty on domestic installations (see Tube- warranty for details). Remote Control Panel (Optional): The control panel switch plate can be removed from the machine and furnished in a remote enclosure if specified at time of order. The switch plate contains / Clean / Off selector switch, Fault Indicator and Manual Harvest / Start button. Standard Size: Tube- S Model's approximately 7/8" Diameter X 3/4" Long (Approximately 58 cylinders / lb) M Model's approximately 1 1/8" Diameter X 1" Long (Approximately 30 cylinders / lb) Crushed approximately 1/4" Thick (Approximately 32 lbs / cubic foot) Operating Conditions: The ice machine shall not be subjected to an atmospheric temperature lower than 50 F nor higher than 90 F, without effect on performance. for condensing and for ice making purposes shall be non-corrosive. The water shall be at a constant pressure of not less than 30 lbs. at the ice machine location. The condition of the water to make satisfactory ice shall be the responsibility of the purchaser. Air-Cooled Condensers: The air-cooled condensers are available as remote units only, with 50/50 split coil and low ambient controls. Vogt requires that the aircooled condensers be purchased from the Vogt factory in order to assure proper sizing and operation. The ice capacity with an aircooled unit will be the same as a water-cooled unit, as long as the ambient temperature does not exceed 95 F. For each 5 F increase in ambient temperature, the ice capacity will be decreased by approximately 3%. UL, NSF & USDA Approved Vogt Tube LLC Sales Phone #: (800) 853-8648 1000 West Ormsby (502) 635-3000 Web Site: www.vogtice.com

HES-40S Tube- Machine Models: 04KA-PFB4-26 = 7/8" O.D. Cylinder, 208/230V,3ph,60hz 04KA-PFB4-46 = 7/8" O.D. Cylinder 460V,3ph,60hz 04KA-PFK4-26 = 7/8" Crushed, 208/230V,3ph,60hz 04KA-PFK4-46 = 7/8" Crushed 460V,3ph,60hz 04KA-PFD4-26 = 7/8" Dual, 208/230V,3ph,60hz 04KA-PFD4-46 = 7/8" Dual 460V,3ph,60hz Note: Condenser type should be entered in last two positions: WC = Cooled, AC = Air Cooled Machine Electrical Information Cooled Machine Air Cooled Machine Making 27.3 32.5 55 40 35.3 40.5 65 50 (A) * Condenser Inlet & Outlet 1" FPT 13.3 15.8 30 20 17.3 19.8 30 20 (B) ** Comp. Discharge & Condenser Return 1 1/8" OD Note: * Cooled Only / ** Air Cooled Only Pump Cutter Drive Condenser Fan 1/2 3.8 1 1/2 4.1 1 2 @ 1/2 4 ea. (8 total) 1 6 156 20.7 3 N/A 6 70 10 3 Efficiency Making Condenser Energy (KWH / 100 lbs) Condenser Type Usage/ 100 lbs of Flow Rate In Out Flow Rate Press. Drop ( o F) (lbs/day) Air (gal) (gpm) (gph) ( o F) ( o F) (gpm) (psig) 50 4065 2.39 3.00 14.4 0.41 24.5 50 66.6 5.9 1.3 60 3835 2.54 3.19 14.4 0.38 23.1 60 73.2 7.4 2.0 70 3615 2.69 3.39 14.4 0.36 21.8 70 80.3 9.5 3.0 80 3415 2.86 3.60 14.4 0.34 20.6 80 86.7 14.7 7.0 90 3230 3.02 3.82 14.4 0.32 19.4 90 93.9 25.1 18.0 Capacities and making water values based on 20% blowdown (harvest cycle only) Refrigerant: Type: Options Available (no charge) System Charge: 90 lbs Optional Dual feature available Alternating (Dual ice machine) Machine Weights: Special Crushed (extra charge) Options Available (extra charge) Machine (w/stainless steel casings) 1 1/2" Long Cylinder (extra charge) Dual Feature Shipping: 1200 lbs General Requirements Special Crushed cutter Operating: 1260 lbs (makeup & condenser) 1 1/2" Long Cylinder Air cooled condenser Minimum Pressure: 30 psig 7 day / 24 hr. Programmable Timer Shipping: 325 lbs Maximum Pressure: 90 psig tank flush valve Operating: 300 lbs High water pressure condenser (extra charge) 50 Hertz cooled Minimum Ambient: 50 o F Power Monitor Vogt LLC 1000 West Ormsby Sales Phone #: (800) 853-8648 Web Site: www.vogtice.com

HES-40M Tube- Machine Models: 04KA-PFB5-26 = 1 1/8" O.D. Cylinder, 208/230V,3ph,60hz 04KA-PFB5-46 = 1 1/8" O.D. Cylinder 460V,3ph,60hz 04KA-PFK5-26 = 1 1/8" Crushed, 208/230V,3ph,60hz 04KA-PFK5-46 = 1 1/8" Crushed 460V,3ph,60hz 04KA-PFD5-26 = 1 1/8" Dual, 208/230V,3ph,60hz 04KA-PFD5-46 = 1 1/8" Dual 460V,3ph,60hz Note: Condenser type should be entered in last two positions: WC = Cooled, AC = Air Cooled Machine Electrical Information Cooled Machine Air Cooled Machine Making 27.3 32.5 55 40 35.3 40.5 65 50 (A) * Condenser Inlet & Outlet 1" FPT 13.3 15.8 30 20 17.3 19.8 30 20 (B) ** Comp. Discharge & Condenser Return 1 1/8" OD Note: * Cooled Only / ** Air Cooled Only Pump Cutter Drive Condenser Fan 1/2 3.8 1 1/2 4.1 1 2 @ 1/2 4 ea. (8 total) 1 6 156 20.7 3 N/A 6 70 10.0 3 Efficiency Making Condenser Energy Usage/ (KWH / 100 lbs) 100 lbs Flow Press. Condenser Type of Flow Rate In Out Rate Drop ( o F) (lbs/day) Air (gal) (gpm) (gph) ( o F) ( o F) (gpm) (psig) 50 3455 2.82 3.56 14.4 0.35 20.8 50 67.2 5.7 1.3 60 3260 3.00 3.78 14.4 0.33 19.6 60 73.6 7.2 2.0 70 3075 3.18 4.02 14.4 0.31 18.5 70 80.8 9.1 3.0 80 2905 3.37 4.27 14.4 0.29 17.5 80 87.0 14.1 6.5 90 2745 3.57 4.52 14.4 0.28 16.5 90 94.1 24.1 16.0 Capacities and making water values based on 20% blowdown (harvest cycle only) Refrigerant: Type: Options Available (no charge) System Charge: 90 lbs Optional Dual feature available Alternating (Dual ice machine) Machine Weights: Special Crushed (extra charge) Options Available (extra charge) Machine (w/stainless steel casings) 1 1/2" Long Cylinder (extra charge) Dual Feature Shipping: 1200 lbs General Requirements Special Crushed cutter Operating: 1260 lbs (makeup & condenser) 1 1/2" Long Cylinder Air cooled condenser Minimum Pressure: 30 psig 7 day / 24 hr. Programmable Timer Shipping: 325 lbs Maximum Pressure: 90 psig tank flush valve Operating: 300 lbs High water pressure condenser (extra charge) 50 Hertz cooled Minimum Ambient: 50 o F Power Monitor Vogt LLC 1000 West Ormsby Sales Phone #: (800) 853-8648 Web Site: www.vogtice.com

HES-30S Tube- Machine Models: 03KA-PFB4-26 = 7/8" O.D. Cylinder, 208/230V,3ph,60hz 03KA-PFB4-46 = 7/8" O.D. Cylinder 460V,3ph,60hz 03KA-PFK4-26 = 7/8" Crushed, 208/230V,3ph,60hz 03KA-PFK4-46 = 7/8" Crushed 460V,3ph,60hz 03KA-PFD4-26 = 7/8" Dual, 208/230V,3ph,60hz 03KA-PFD4-46 = 7/8" Dual 460V,3ph,60hz Note: Condenser type should be entered in last two positions: WC = Cooled, AC = Air Cooled Machine Electrical Information Cooled Machine Air Cooled Machine Making 21.6 25.4 45 30 29.6 33.4 50 40 (A) * Condenser Inlet & Outlet 3/4" FPT 11.5 13.6 25 20 15.5 17.6 30 20 (B) ** Comp. Discharge & Condenser Return 1 1/8" OD Note: * Cooled Only / ** Air Cooled Only Pump Cutter Drive Condenser Fan 1/2 3.8 1 1/2 4.1 1 2 @ 1/2 4 ea. (8 total) 1 4 99 15.0 3 N/A 4 50 8.2 3 Efficiency Making Condenser Energy (KWH / 100 lbs) Condenser Type Usage/ 100 lbs of Flow Rate In Out Flow Rate Press. Drop ( o F) (lbs/day) Air (gal) (gpm) (gph) ( o F) ( o F) (gpm) (psig) 50 3070 2.43 3.27 14.4 0.31 18.5 50 67.4 3.8 2.9 60 2920 2.56 3.45 14.4 0.29 17.6 60 74.0 4.7 4.5 70 2745 2.73 3.69 14.4 0.28 16.5 70 81.2 5.9 9.0 80 2535 2.97 4.01 14.4 0.25 15.3 80 87.9 8.4 15.0 90 2230 3.28 4.44 14.4 0.22 13.4 90 94.5 14.7 26.0 Capacities and making water values based on 20% blowdown (harvest cycle only) Refrigerant: Type: Options Available (no charge) System Charge: 90 lbs Optional Dual feature available Alternating (Dual ice machine) Machine Weights: Special Crushed (extra charge) Options Available (extra charge) Machine (w/stainless steel casings) 1 1/2" Long Cylinder (extra charge) Dual Feature Shipping: 1150 lbs General Requirements Special Crushed cutter Operating: 1210 lbs (makeup & condenser) 1 1/2" Long Cylinder Air cooled condenser Minimum Pressure: 30 psig 7 day / 24 hr. Programmable Timer Shipping: 310 lbs Maximum Pressure: 90 psig tank flush valve Operating: 275 lbs High water pressure condenser (extra charge) 50 Hertz cooled Minimum Ambient: 50 o F Power Monitor Vogt LLC 1000 West Ormsby Sales Phone #: (800) 853-8648 Web Site: www.vogtice.com

HES-30M Tube- Machine Models: 03KA-PFB5-26 = 1 1/8" O.D. Cylinder, 208/230V,3ph,60hz 03KA-PFB5-46 = 1 1/8" O.D. Cylinder 460V,3ph,60hz 03KA-PFK5-26 = 1 1/8" Crushed, 208/230V,3ph,60hz 03KA-PFK5-46 = 1 1/8" Crushed 460V,3ph,60hz 03KA-PFD5-26 = 1 1/8" Dual, 208/230V,3ph,60hz 03KA-PFD5-46 = 1 1/8" Dual 460V,3ph,60hz Note: Condenser type should be entered in last two positions: WC = Cooled, AC = Air Cooled Machine Electrical Information Cooled Machine Air Cooled Machine Making 21.6 25.4 45 30 29.6 33.4 50 40 (A) * Condenser Inlet & Outlet 3/4" FPT 11.5 13.6 25 20 15.5 17.6 30 20 (B) ** Comp. Discharge & Condenser Return 1 1/8" OD Note: * Cooled Only / ** Air Cooled Only Pump Cutter Drive Condenser Fan 1/2 3.8 1 1/2 4.1 1 2 @ 1/2 4 ea. (8 total) 1 4 99 15.0 3 N/A 4 50 8.2 3 Efficiency Making Condenser Energy Usage/ (KWH / 100 lbs) 100 lbs Flow Press. Condenser Type of Flow Rate In Out Rate Drop ( o F) (lbs/day) Air (gal) (gpm) (gph) ( o F) ( o F) (gpm) (psig) 50 2610 2.88 3.89 14.4 0.26 15.7 50 68.3 3.6 2.9 60 2485 3.03 4.10 14.4 0.25 15.0 60 75.0 4.4 4.5 70 2335 3.23 4.37 14.4 0.23 14.1 70 81.6 5.7 9.0 80 2155 3.51 4.75 14.4 0.22 13.0 80 88.1 8.2 15.0 90 1955 3.88 5.26 14.4 0.20 11.8 90 94.6 14.3 26.0 Capacities and making water values based on 20% blowdown (harvest cycle only) Refrigerant: Type: Options Available (no charge) System Charge: 90 lbs Optional Dual feature available Alternating (Dual ice machine) Machine Weights: Special Crushed (extra charge) Options Available (extra charge) Machine (w/stainless steel casings) 1 1/2" Long Cylinder (extra charge) Dual Feature Shipping: 1150 lbs General Requirements Special Crushed cutter Operating: 1210 lbs (makeup & condenser) 1 1/2" Long Cylinder Air cooled condenser Minimum Pressure: 30 psig 7 day / 24 hr. Programmable Timer Shipping: 310 lbs Maximum Pressure: 90 psig tank flush valve Operating: 275 lbs High water pressure condenser (extra charge) 50 Hertz cooled Minimum Ambient: 50 o F Power Monitor Vogt LLC 1000 West Ormsby Sales Phone #: (800) 853-8648 Web Site: www.vogtice.com

HES-20S Tube- Machine Models: 02KA-PFB4-26 = 7/8" O.D. Cylinder, 208/230V,3ph,60hz 02KA-PFB4-46 = 7/8" O.D. Cylinder 460V,3ph,60hz 02KA-PFK4-26 = 7/8" Crushed, 208/230V,3ph,60hz 02KA-PFK4-46 = 7/8" Crushed 460V,3ph,60hz 02KA-PFD4-26 = 7/8" Dual, 208/230V,3ph,60hz 02KA-PFD4-46 = 7/8" Dual 460V,3ph,60hz Note: Condenser type should be entered in last two positions: WC = Cooled, AC = Air Cooled Machine Electrical Information Cooled Machine Air Cooled Machine Making 18.0 20.9 35 25 20.5 23.4 35 25 (A) * Condenser Inlet & Outlet 3/4" FPT 9.0 10.4 20 15 10.3 11.7 20 15 (B) ** Comp. Discharge & Condenser Return 1 1/8" OD Note: * Cooled Only / ** Air Cooled Only Pump Cutter Drive Condenser Fan 1/2 3.8 1 1/2 4.1 1 1/3 2.5 1 3 77 11.4 3 N/A 3 39 5.7 3 Efficiency Making Condenser Energy Usage/ (KWH / 100 lbs) 100 lbs Flow Press. Condenser Type of Flow Rate In Out Rate Drop ( o F) (lbs/day) Air (gal) (gpm) (gph) ( o F) ( o F) (gpm) (psig) 50 2075 3.10 3.52 14.4 0.21 12.5 50 83.9 1.3 0.4 60 1945 3.31 3.76 14.4 0.20 11.7 60 87.5 1.6 0.6 70 1815 3.56 4.04 14.4 0.18 10.9 70 90.0 2.2 1.0 80 1690 3.84 4.36 14.4 0.17 10.2 80 91.0 4.0 3.3 90 1560 4.16 4.73 14.4 0.16 9.4 90 96.1 7.2 10.0 Capacities and making water values based on 20% blowdown (harvest cycle only) Refrigerant: Type: Options Available (no charge) System Charge: 90 lbs Optional Dual feature available Alternating (Dual ice machine) Machine Weights: Special Crushed (extra charge) Options Available (extra charge) Machine (w/stainless steel casings) 1 1/2" Long Cylinder (extra charge) Dual Feature Shipping: 1050 lbs General Requirements Special Crushed cutter Operating: 1110 lbs (makeup & condenser) 1 1/2" Long Cylinder Air cooled condenser Minimum Pressure: 30 psig 7 day / 24 hr. Programmable Timer Shipping: 195 lbs Maximum Pressure: 90 psig tank flush valve Operating: 167 lbs High water pressure condenser (extra charge) 50 Hertz cooled Minimum Ambient: 50 o F Power Monitor Vogt LLC 1000 West Ormsby Sales Phone #: (800) 853-8648 Web Site: www.vogtice.com

HES-20M Tube- Machine Models: 02KA-PFB5-26 = 1 1/8" O.D. Cylinder, 208/230V,3ph,60hz 02KA-PFB5-46 = 1 1/8" O.D. Cylinder 460V,3ph,60hz 02KA-PFK5-26 = 1 1/8" Crushed, 208/230V,3ph,60hz 02KA-PFK5-46 = 1 1/8" Crushed 460V,3ph,60hz 02KA-PFD5-26 = 1 1/8" Dual, 208/230V,3ph,60hz 02KA-PFD5-46 = 1 1/8" Dual 460V,3ph,60hz Note: Condenser type should be entered in last two positions: WC = Cooled, AC = Air Cooled Machine Electrical Information Cooled Machine Air Cooled Machine Making 18.0 20.9 35 25 20.5 23.4 35 25 (A) * Condenser Inlet & Outlet 3/4" FPT 9.0 10.4 20 15 10.3 11.7 20 15 (B) ** Comp. Discharge & Condenser Return 1 1/8" OD Note: * Cooled Only / ** Air Cooled Only Pump Cutter Drive Condenser Fan 1/2 3.8 1 1/2 4.1 1 1/3 2.5 1 3 77 11.4 3 N/A 3 39 5.7 3 Efficiency Making Condenser Energy (KWH / 100 lbs) Condenser Type Usage/ 100 lbs of Flow Rate In Out Flow Rate Press. Drop ( o F) (lbs/day) Air (gal) (gpm) (gph) ( o F) ( o F) (gpm) (psig) 50 1765 3.62 4.11 14.4 0.18 10.6 50 86.7 1.2 0.4 60 1655 3.87 4.39 14.4 0.17 10.0 60 89.3 1.5 0.6 70 1545 4.15 4.71 14.4 0.15 9.3 70 91.0 2.1 1.0 80 1435 4.48 5.08 14.4 0.14 8.6 80 91.3 3.9 3.3 90 1325 4.86 5.52 14.4 0.13 8.0 90 96.4 6.9 10.0 Capacities and making water values based on 20% blowdown (harvest cycle only) Refrigerant: Type: Options Available (no charge) System Charge: 90 lbs Optional Dual feature available Alternating (Dual ice machine) Machine Weights: Special Crushed (extra charge) Options Available (extra charge) Machine (w/stainless steel casings) 1 1/2" Long Cylinder (extra charge) Dual Feature Shipping: 1050 lbs General Requirements Special Crushed cutter Operating: 1110 lbs (makeup & condenser) 1 1/2" Long Cylinder Air cooled condenser Minimum Pressure: 30 psig 7 day / 24 hr. Programmable Timer Shipping: 195 lbs Maximum Pressure: 90 psig tank flush valve Operating: 167 lbs High water pressure condenser (extra charge) 50 Hertz cooled Minimum Ambient: 50 o F Power Monitor Vogt LLC 1000 West Ormsby Sales Phone #: (800) 853-8648 Web Site: www.vogtice.com