Models: HES-20S, HES-20M HES-30S, HES-30M HES-40S, HES-40M Tube- Machines Standard Construction: All surfaces in contact with water or ice are of stainless steel or other rust resistant material. External finish is available in heavy-duty ABS panels or stainless seel panels. Units are factory tested and adjusted for cylinder ice and can be manually switched to crushed ice in the field if required. Unit can be set for crushed ice at factory at no extra charge if specified on order. Electrical Requirements: Standard is 208/230V, 3ph, 60hz. Other configurations are available on request including 50hz. Dual Selector Switch (Optional): The selector switch has three settings: 1. Cylinder (Tube-) only 2. Crushed only 3. Both cylinder and crushed ice for split bins Tube- Evaporator and Refrigerant Receiver: Manufactured in accordance with the A.S.M.E. Code with a 25-year warranty on domestic installations (see Tube- warranty for details). Remote Control Panel (Optional): The control panel switch plate can be removed from the machine and furnished in a remote enclosure if specified at time of order. The switch plate contains / Clean / Off selector switch, Fault Indicator and Manual Harvest / Start button. Standard Size: Tube- S Model's approximately 7/8" Diameter X 3/4" Long (Approximately 58 cylinders / lb) M Model's approximately 1 1/8" Diameter X 1" Long (Approximately 30 cylinders / lb) Crushed approximately 1/4" Thick (Approximately 32 lbs / cubic foot) Operating Conditions: The ice machine shall not be subjected to an atmospheric temperature lower than 50 F nor higher than 90 F, without effect on performance. for condensing and for ice making purposes shall be non-corrosive. The water shall be at a constant pressure of not less than 30 lbs. at the ice machine location. The condition of the water to make satisfactory ice shall be the responsibility of the purchaser. Air-Cooled Condensers: The air-cooled condensers are available as remote units only, with 50/50 split coil and low ambient controls. Vogt requires that the aircooled condensers be purchased from the Vogt factory in order to assure proper sizing and operation. The ice capacity with an aircooled unit will be the same as a water-cooled unit, as long as the ambient temperature does not exceed 95 F. For each 5 F increase in ambient temperature, the ice capacity will be decreased by approximately 3%. UL, NSF & USDA Approved Vogt Tube LLC Sales Phone #: (800) 853-8648 1000 West Ormsby (502) 635-3000 Web Site: www.vogtice.com
HES-40S Tube- Machine Models: 04KA-PFB4-26 = 7/8" O.D. Cylinder, 208/230V,3ph,60hz 04KA-PFB4-46 = 7/8" O.D. Cylinder 460V,3ph,60hz 04KA-PFK4-26 = 7/8" Crushed, 208/230V,3ph,60hz 04KA-PFK4-46 = 7/8" Crushed 460V,3ph,60hz 04KA-PFD4-26 = 7/8" Dual, 208/230V,3ph,60hz 04KA-PFD4-46 = 7/8" Dual 460V,3ph,60hz Note: Condenser type should be entered in last two positions: WC = Cooled, AC = Air Cooled Machine Electrical Information Cooled Machine Air Cooled Machine Making 27.3 32.5 55 40 35.3 40.5 65 50 (A) * Condenser Inlet & Outlet 1" FPT 13.3 15.8 30 20 17.3 19.8 30 20 (B) ** Comp. Discharge & Condenser Return 1 1/8" OD Note: * Cooled Only / ** Air Cooled Only Pump Cutter Drive Condenser Fan 1/2 3.8 1 1/2 4.1 1 2 @ 1/2 4 ea. (8 total) 1 6 156 20.7 3 N/A 6 70 10 3 Efficiency Making Condenser Energy (KWH / 100 lbs) Condenser Type Usage/ 100 lbs of Flow Rate In Out Flow Rate Press. Drop ( o F) (lbs/day) Air (gal) (gpm) (gph) ( o F) ( o F) (gpm) (psig) 50 4065 2.39 3.00 14.4 0.41 24.5 50 66.6 5.9 1.3 60 3835 2.54 3.19 14.4 0.38 23.1 60 73.2 7.4 2.0 70 3615 2.69 3.39 14.4 0.36 21.8 70 80.3 9.5 3.0 80 3415 2.86 3.60 14.4 0.34 20.6 80 86.7 14.7 7.0 90 3230 3.02 3.82 14.4 0.32 19.4 90 93.9 25.1 18.0 Capacities and making water values based on 20% blowdown (harvest cycle only) Refrigerant: Type: Options Available (no charge) System Charge: 90 lbs Optional Dual feature available Alternating (Dual ice machine) Machine Weights: Special Crushed (extra charge) Options Available (extra charge) Machine (w/stainless steel casings) 1 1/2" Long Cylinder (extra charge) Dual Feature Shipping: 1200 lbs General Requirements Special Crushed cutter Operating: 1260 lbs (makeup & condenser) 1 1/2" Long Cylinder Air cooled condenser Minimum Pressure: 30 psig 7 day / 24 hr. Programmable Timer Shipping: 325 lbs Maximum Pressure: 90 psig tank flush valve Operating: 300 lbs High water pressure condenser (extra charge) 50 Hertz cooled Minimum Ambient: 50 o F Power Monitor Vogt LLC 1000 West Ormsby Sales Phone #: (800) 853-8648 Web Site: www.vogtice.com
HES-40M Tube- Machine Models: 04KA-PFB5-26 = 1 1/8" O.D. Cylinder, 208/230V,3ph,60hz 04KA-PFB5-46 = 1 1/8" O.D. Cylinder 460V,3ph,60hz 04KA-PFK5-26 = 1 1/8" Crushed, 208/230V,3ph,60hz 04KA-PFK5-46 = 1 1/8" Crushed 460V,3ph,60hz 04KA-PFD5-26 = 1 1/8" Dual, 208/230V,3ph,60hz 04KA-PFD5-46 = 1 1/8" Dual 460V,3ph,60hz Note: Condenser type should be entered in last two positions: WC = Cooled, AC = Air Cooled Machine Electrical Information Cooled Machine Air Cooled Machine Making 27.3 32.5 55 40 35.3 40.5 65 50 (A) * Condenser Inlet & Outlet 1" FPT 13.3 15.8 30 20 17.3 19.8 30 20 (B) ** Comp. Discharge & Condenser Return 1 1/8" OD Note: * Cooled Only / ** Air Cooled Only Pump Cutter Drive Condenser Fan 1/2 3.8 1 1/2 4.1 1 2 @ 1/2 4 ea. (8 total) 1 6 156 20.7 3 N/A 6 70 10.0 3 Efficiency Making Condenser Energy Usage/ (KWH / 100 lbs) 100 lbs Flow Press. Condenser Type of Flow Rate In Out Rate Drop ( o F) (lbs/day) Air (gal) (gpm) (gph) ( o F) ( o F) (gpm) (psig) 50 3455 2.82 3.56 14.4 0.35 20.8 50 67.2 5.7 1.3 60 3260 3.00 3.78 14.4 0.33 19.6 60 73.6 7.2 2.0 70 3075 3.18 4.02 14.4 0.31 18.5 70 80.8 9.1 3.0 80 2905 3.37 4.27 14.4 0.29 17.5 80 87.0 14.1 6.5 90 2745 3.57 4.52 14.4 0.28 16.5 90 94.1 24.1 16.0 Capacities and making water values based on 20% blowdown (harvest cycle only) Refrigerant: Type: Options Available (no charge) System Charge: 90 lbs Optional Dual feature available Alternating (Dual ice machine) Machine Weights: Special Crushed (extra charge) Options Available (extra charge) Machine (w/stainless steel casings) 1 1/2" Long Cylinder (extra charge) Dual Feature Shipping: 1200 lbs General Requirements Special Crushed cutter Operating: 1260 lbs (makeup & condenser) 1 1/2" Long Cylinder Air cooled condenser Minimum Pressure: 30 psig 7 day / 24 hr. Programmable Timer Shipping: 325 lbs Maximum Pressure: 90 psig tank flush valve Operating: 300 lbs High water pressure condenser (extra charge) 50 Hertz cooled Minimum Ambient: 50 o F Power Monitor Vogt LLC 1000 West Ormsby Sales Phone #: (800) 853-8648 Web Site: www.vogtice.com
HES-30S Tube- Machine Models: 03KA-PFB4-26 = 7/8" O.D. Cylinder, 208/230V,3ph,60hz 03KA-PFB4-46 = 7/8" O.D. Cylinder 460V,3ph,60hz 03KA-PFK4-26 = 7/8" Crushed, 208/230V,3ph,60hz 03KA-PFK4-46 = 7/8" Crushed 460V,3ph,60hz 03KA-PFD4-26 = 7/8" Dual, 208/230V,3ph,60hz 03KA-PFD4-46 = 7/8" Dual 460V,3ph,60hz Note: Condenser type should be entered in last two positions: WC = Cooled, AC = Air Cooled Machine Electrical Information Cooled Machine Air Cooled Machine Making 21.6 25.4 45 30 29.6 33.4 50 40 (A) * Condenser Inlet & Outlet 3/4" FPT 11.5 13.6 25 20 15.5 17.6 30 20 (B) ** Comp. Discharge & Condenser Return 1 1/8" OD Note: * Cooled Only / ** Air Cooled Only Pump Cutter Drive Condenser Fan 1/2 3.8 1 1/2 4.1 1 2 @ 1/2 4 ea. (8 total) 1 4 99 15.0 3 N/A 4 50 8.2 3 Efficiency Making Condenser Energy (KWH / 100 lbs) Condenser Type Usage/ 100 lbs of Flow Rate In Out Flow Rate Press. Drop ( o F) (lbs/day) Air (gal) (gpm) (gph) ( o F) ( o F) (gpm) (psig) 50 3070 2.43 3.27 14.4 0.31 18.5 50 67.4 3.8 2.9 60 2920 2.56 3.45 14.4 0.29 17.6 60 74.0 4.7 4.5 70 2745 2.73 3.69 14.4 0.28 16.5 70 81.2 5.9 9.0 80 2535 2.97 4.01 14.4 0.25 15.3 80 87.9 8.4 15.0 90 2230 3.28 4.44 14.4 0.22 13.4 90 94.5 14.7 26.0 Capacities and making water values based on 20% blowdown (harvest cycle only) Refrigerant: Type: Options Available (no charge) System Charge: 90 lbs Optional Dual feature available Alternating (Dual ice machine) Machine Weights: Special Crushed (extra charge) Options Available (extra charge) Machine (w/stainless steel casings) 1 1/2" Long Cylinder (extra charge) Dual Feature Shipping: 1150 lbs General Requirements Special Crushed cutter Operating: 1210 lbs (makeup & condenser) 1 1/2" Long Cylinder Air cooled condenser Minimum Pressure: 30 psig 7 day / 24 hr. Programmable Timer Shipping: 310 lbs Maximum Pressure: 90 psig tank flush valve Operating: 275 lbs High water pressure condenser (extra charge) 50 Hertz cooled Minimum Ambient: 50 o F Power Monitor Vogt LLC 1000 West Ormsby Sales Phone #: (800) 853-8648 Web Site: www.vogtice.com
HES-30M Tube- Machine Models: 03KA-PFB5-26 = 1 1/8" O.D. Cylinder, 208/230V,3ph,60hz 03KA-PFB5-46 = 1 1/8" O.D. Cylinder 460V,3ph,60hz 03KA-PFK5-26 = 1 1/8" Crushed, 208/230V,3ph,60hz 03KA-PFK5-46 = 1 1/8" Crushed 460V,3ph,60hz 03KA-PFD5-26 = 1 1/8" Dual, 208/230V,3ph,60hz 03KA-PFD5-46 = 1 1/8" Dual 460V,3ph,60hz Note: Condenser type should be entered in last two positions: WC = Cooled, AC = Air Cooled Machine Electrical Information Cooled Machine Air Cooled Machine Making 21.6 25.4 45 30 29.6 33.4 50 40 (A) * Condenser Inlet & Outlet 3/4" FPT 11.5 13.6 25 20 15.5 17.6 30 20 (B) ** Comp. Discharge & Condenser Return 1 1/8" OD Note: * Cooled Only / ** Air Cooled Only Pump Cutter Drive Condenser Fan 1/2 3.8 1 1/2 4.1 1 2 @ 1/2 4 ea. (8 total) 1 4 99 15.0 3 N/A 4 50 8.2 3 Efficiency Making Condenser Energy Usage/ (KWH / 100 lbs) 100 lbs Flow Press. Condenser Type of Flow Rate In Out Rate Drop ( o F) (lbs/day) Air (gal) (gpm) (gph) ( o F) ( o F) (gpm) (psig) 50 2610 2.88 3.89 14.4 0.26 15.7 50 68.3 3.6 2.9 60 2485 3.03 4.10 14.4 0.25 15.0 60 75.0 4.4 4.5 70 2335 3.23 4.37 14.4 0.23 14.1 70 81.6 5.7 9.0 80 2155 3.51 4.75 14.4 0.22 13.0 80 88.1 8.2 15.0 90 1955 3.88 5.26 14.4 0.20 11.8 90 94.6 14.3 26.0 Capacities and making water values based on 20% blowdown (harvest cycle only) Refrigerant: Type: Options Available (no charge) System Charge: 90 lbs Optional Dual feature available Alternating (Dual ice machine) Machine Weights: Special Crushed (extra charge) Options Available (extra charge) Machine (w/stainless steel casings) 1 1/2" Long Cylinder (extra charge) Dual Feature Shipping: 1150 lbs General Requirements Special Crushed cutter Operating: 1210 lbs (makeup & condenser) 1 1/2" Long Cylinder Air cooled condenser Minimum Pressure: 30 psig 7 day / 24 hr. Programmable Timer Shipping: 310 lbs Maximum Pressure: 90 psig tank flush valve Operating: 275 lbs High water pressure condenser (extra charge) 50 Hertz cooled Minimum Ambient: 50 o F Power Monitor Vogt LLC 1000 West Ormsby Sales Phone #: (800) 853-8648 Web Site: www.vogtice.com
HES-20S Tube- Machine Models: 02KA-PFB4-26 = 7/8" O.D. Cylinder, 208/230V,3ph,60hz 02KA-PFB4-46 = 7/8" O.D. Cylinder 460V,3ph,60hz 02KA-PFK4-26 = 7/8" Crushed, 208/230V,3ph,60hz 02KA-PFK4-46 = 7/8" Crushed 460V,3ph,60hz 02KA-PFD4-26 = 7/8" Dual, 208/230V,3ph,60hz 02KA-PFD4-46 = 7/8" Dual 460V,3ph,60hz Note: Condenser type should be entered in last two positions: WC = Cooled, AC = Air Cooled Machine Electrical Information Cooled Machine Air Cooled Machine Making 18.0 20.9 35 25 20.5 23.4 35 25 (A) * Condenser Inlet & Outlet 3/4" FPT 9.0 10.4 20 15 10.3 11.7 20 15 (B) ** Comp. Discharge & Condenser Return 1 1/8" OD Note: * Cooled Only / ** Air Cooled Only Pump Cutter Drive Condenser Fan 1/2 3.8 1 1/2 4.1 1 1/3 2.5 1 3 77 11.4 3 N/A 3 39 5.7 3 Efficiency Making Condenser Energy Usage/ (KWH / 100 lbs) 100 lbs Flow Press. Condenser Type of Flow Rate In Out Rate Drop ( o F) (lbs/day) Air (gal) (gpm) (gph) ( o F) ( o F) (gpm) (psig) 50 2075 3.10 3.52 14.4 0.21 12.5 50 83.9 1.3 0.4 60 1945 3.31 3.76 14.4 0.20 11.7 60 87.5 1.6 0.6 70 1815 3.56 4.04 14.4 0.18 10.9 70 90.0 2.2 1.0 80 1690 3.84 4.36 14.4 0.17 10.2 80 91.0 4.0 3.3 90 1560 4.16 4.73 14.4 0.16 9.4 90 96.1 7.2 10.0 Capacities and making water values based on 20% blowdown (harvest cycle only) Refrigerant: Type: Options Available (no charge) System Charge: 90 lbs Optional Dual feature available Alternating (Dual ice machine) Machine Weights: Special Crushed (extra charge) Options Available (extra charge) Machine (w/stainless steel casings) 1 1/2" Long Cylinder (extra charge) Dual Feature Shipping: 1050 lbs General Requirements Special Crushed cutter Operating: 1110 lbs (makeup & condenser) 1 1/2" Long Cylinder Air cooled condenser Minimum Pressure: 30 psig 7 day / 24 hr. Programmable Timer Shipping: 195 lbs Maximum Pressure: 90 psig tank flush valve Operating: 167 lbs High water pressure condenser (extra charge) 50 Hertz cooled Minimum Ambient: 50 o F Power Monitor Vogt LLC 1000 West Ormsby Sales Phone #: (800) 853-8648 Web Site: www.vogtice.com
HES-20M Tube- Machine Models: 02KA-PFB5-26 = 1 1/8" O.D. Cylinder, 208/230V,3ph,60hz 02KA-PFB5-46 = 1 1/8" O.D. Cylinder 460V,3ph,60hz 02KA-PFK5-26 = 1 1/8" Crushed, 208/230V,3ph,60hz 02KA-PFK5-46 = 1 1/8" Crushed 460V,3ph,60hz 02KA-PFD5-26 = 1 1/8" Dual, 208/230V,3ph,60hz 02KA-PFD5-46 = 1 1/8" Dual 460V,3ph,60hz Note: Condenser type should be entered in last two positions: WC = Cooled, AC = Air Cooled Machine Electrical Information Cooled Machine Air Cooled Machine Making 18.0 20.9 35 25 20.5 23.4 35 25 (A) * Condenser Inlet & Outlet 3/4" FPT 9.0 10.4 20 15 10.3 11.7 20 15 (B) ** Comp. Discharge & Condenser Return 1 1/8" OD Note: * Cooled Only / ** Air Cooled Only Pump Cutter Drive Condenser Fan 1/2 3.8 1 1/2 4.1 1 1/3 2.5 1 3 77 11.4 3 N/A 3 39 5.7 3 Efficiency Making Condenser Energy (KWH / 100 lbs) Condenser Type Usage/ 100 lbs of Flow Rate In Out Flow Rate Press. Drop ( o F) (lbs/day) Air (gal) (gpm) (gph) ( o F) ( o F) (gpm) (psig) 50 1765 3.62 4.11 14.4 0.18 10.6 50 86.7 1.2 0.4 60 1655 3.87 4.39 14.4 0.17 10.0 60 89.3 1.5 0.6 70 1545 4.15 4.71 14.4 0.15 9.3 70 91.0 2.1 1.0 80 1435 4.48 5.08 14.4 0.14 8.6 80 91.3 3.9 3.3 90 1325 4.86 5.52 14.4 0.13 8.0 90 96.4 6.9 10.0 Capacities and making water values based on 20% blowdown (harvest cycle only) Refrigerant: Type: Options Available (no charge) System Charge: 90 lbs Optional Dual feature available Alternating (Dual ice machine) Machine Weights: Special Crushed (extra charge) Options Available (extra charge) Machine (w/stainless steel casings) 1 1/2" Long Cylinder (extra charge) Dual Feature Shipping: 1050 lbs General Requirements Special Crushed cutter Operating: 1110 lbs (makeup & condenser) 1 1/2" Long Cylinder Air cooled condenser Minimum Pressure: 30 psig 7 day / 24 hr. Programmable Timer Shipping: 195 lbs Maximum Pressure: 90 psig tank flush valve Operating: 167 lbs High water pressure condenser (extra charge) 50 Hertz cooled Minimum Ambient: 50 o F Power Monitor Vogt LLC 1000 West Ormsby Sales Phone #: (800) 853-8648 Web Site: www.vogtice.com