TE CONNECTIVITY <fiber count> <fiber type> <flame rating> MM/YY SO<shop order number> XXXXX FEET

Similar documents
Fiber Optic Distribution Cables (6-144 Fibers)

Multipurpose Cables (indoor/outdoor), Multipurpose central tube cable (maxibundle) with glass yarn armouring A-DQ(BN)H 4-24

Industrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers

FTTX Solutions Mini Rapid Fiber Distribution Terminal (RDT)

Data sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1

Data sheet OpDAT universal cable 1x24 OM4 - bend insensitive

Data sheet OpDAT mini breakout cable 24x1 OM4 - bend insensitive

outdoor and indoor campus backbone, building backbone (riser) FDDI, Gigabit Ethernet and ATM Easy to install direct burial halogen-free

GUCN. Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection v13.

industry solutions: military

GCRG. Multi Loose Tube Cables Universal Indoor / Outdoor A/I-DQ(ZN)BH Improved Rodent Protection v7.0. Ordering Information.

OPTICAL. Micromodule DW About Us. > IEC nd Ed. According to. > EN nd Ed. FTTx

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

Duct Cable GYTS-144B1.3

SECTION COMMUNICATIONS OPTICAL FIBER BACKBONE CABLING

Fibre Optic Cable. Catalogue.

GOF Indoor and Outdoor Cables. Documentation VWL Version 2.2 Source Code R

GUSA. Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection. Ordering Information.

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK

GUSN. Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection. Ordering Information.

Qualification Test Report LightCrimp* Plus Singlemode and Multimode LC Connector (Field Installable)

GBRD. Multi Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection. Ordering Information. Applications. Features & Benefits

GOF Indoor and Outdoor Cables. Documentation VWL Version 1.1 Source Code M

Easy to install in ducts, tunnels and trenches by means of compressed air or pulling wire. Suitable for direct burial (crush 400 N/cm).

Optical Fibre Cable Technical Specification. Duct Cable GYTA-72B1.3

Ø 1000 * 588 mm 50 kg

FiberExpress Solutions

Jan07 Rev B

Sumitomo Fiber Specification SE-6** Non-Zero Dispersion Shifted Single-Mode Fiber. PureGuide SM Optical Fiber, TIA Type IVd. Issued: November 2003

Sumitomo Fiber Specification SE-9** Non-Zero Dispersion Shifted (NZDF) Zero Water Peak Large Effective Area Single Mode Fiber

Qualification Test Report LC Duplex Adapter For LC Cutouts

13-SDMS-02 REV. 00 SPECIFICATIONS FOR NON-METALLIC, TIGHT BUFFERED & RETRACTABLE, MICRO FIBER OPTIC CABLE FOR INTERNAL INSTALLATION

Fibre optic media options and trends

MT-RJ Optical Fiber System Field Testing

HELKAMA. Optical Fibre Cables

Apr06 Rev A

STANDARD FOR INDOOR-OUTDOOR OPTICAL FIBER CABLE

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

STANDARD FOR INDOOR-OUTDOOR OPTICAL FIBER CABLE

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.

TELECOM SOLUTIONS CABLE CATALOGUE INNOVATIVE FIBRE OPTIC CABLE SOLUTIONS

Attenuators. Fiber Optic Products Catalog. Singlemode Build Out Attenuators. Product Facts. Applications. Customizable Features. Available Collateral

Universal Connectivity Platform A Modular Approach to Infrastructure Design

Fiber Optic Patch Cord and Pigtails

/Oct/2014 Rev B

. SECTION CONTROL-VOLTAGE ELECTRICAL POWER CABLES

4120 Fire Alarm Network Reference

RLH Industries, Inc. Cleaning and Testing Fiber Optic Cable. Reference Guide MD A 0507

COMMERCIAL PROTOCOLS AND AEROSPACE CABLING: FINDING THE RIGHT BALANCE

CAT5E DIRECT BURIAL (FLOODED CORE) 24AWG, UTP, 4 PAIR, SOLID 1000 PULL BOX /CMXF

CHALLENGE OF THE NEW OPTICAL FIBRE TECHNOLOGIES

OPTICAL FIBER SOLUTIONS

SPECIAL ELECTRICAL AND OPTICAL CABLES

Jul07 Rev C

/Oct/2014 Rev E

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for Panel and Remote Mounting. Features. Operation.

Hands-On Fiber Optics ISP/OSP - Advanced Combo- Tech

Technical Publication

Specification No.CSC-131/R-1/DH//UH/P&D/ Technical Specifications. for 24 Fiber/48 Fiber Unarmoured. Underground Fibre.

Hands-On Fiber Optic ISP / OSP Combo-Tech Splicing, Termination & Testing

Design Requirements Provide work area copper cable (CAT-5 or CAT-6) in accordance with TIA-568-2, with a thermoplastic jacket colored as follows:

Ribbon Breakout Kit Installation Instructions

Fibre (TIA) Field Test Specification

SECTION CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY

Cat 6 Shielded Patch cords

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. YD/T Translated English of Chinese Standard: YD/T

Category 5e Products

The Rise of Tier 2 Testing

Wire and Cable. For more information on these Tyco Electronics products, visit the following website:

Tether and Umbilical Cables for Remotely Operated Vehicles

TE Connectivity's AMP NETCONNECT Cable Management

Fibre Specification Standards

SiBar Thyristor Surge Protectors. TVBxxxNSA-L Series. Benefits: Features: Applications:

Cat 6 Unshielded Patch cords

Fiber Tes)ng 101 Essen)als Every Network Analyst Needs to Know. David S(llwell BCNET Oscar Rondon BCNET Gwenn Amice - EXFO

STANDARD CONFORMANCE

Special Provision No. 683S28 December 2017

DNVGL-CP-0402 Edition February 2016

SiBar Thyristor Surge Protectors. TVBxxxSA-L Series. Benefits: Features: Applications:

4-Channel Contact Closure Fiber Link Card System

Simplex ES Network. ES Net Network Applications, Communications, Options and Specifications. ES Net features. UL, ULC Listed*

Fiber Optics for Todays Industry Applications

Fiber Optics. VIS / NIR Multimode, Feedthroughs. Ultrahigh Vacuum CF Flange Feedthrough. 4 x 1 CF Flange Feedthrough

Application Engineering Note. Importance of Jacket Crimping

FIST-EDSA-D4. 3 Feeder cable/ducts (max 16 mm) 4 Drop cable (DB cable or guiding tubes 5-8 mm) 5 Adding drop cable. 6 Gel part replacement

FIRE RESISTANT CABLES

FEB 16 Rev T

IFS SFP Tranceivers User Manual

NG4access ODF Platform Standard Chassis Installation Manual

Fiber Optic and CAT 5, 6, 7 and 8 Installer Premise Cabling

SECTION COMMUNICATIONS PATCH CORDS, STATION CORDS AND CROSS CONNECT WIRE

Product Specification CAT 6 UNSHIELDED PATCH CORDS

SECTION COMMUNICATIONS FIBER CABINETS, ADAPTERS AND CONNECTORS

/Mar/2014 Rev A

Category 5 Premise Wire

Qualification Test Report. AMP-TWIST Series Jacks for Class EA systems

SiBar Thyristor Surge Protectors. TVBxxxRSC-L Series. Benefits: Features: Applications:

Product Catalogue. External Management

Installation Considerations for Pipelines

9 W, 15 W and 25 W Industrial Fiber Laser Systems IFL Series

Transcription:

Optic Backbone Distribution Cables 900um Buffered Aramid Yarn Strength Members Outer 6 or 12 Subunit Central Strength Member Outer Ripcord Single Unit Cable 6-24 Multi-Unit Cable 24-144 Description: TE Connectivity backbone distribution cables are designed for routing between communications closets, as intrabuilding backbone cables. Distribution cables are all-dielectric and consist of 900µm tight buffered fibers surrounded by aramid yarn strength members and a flexible thermoplastic outer jacket. Twenty-four, and higher fiber count constructions have two or more subunits and a central strength member (24 fiber side by side constructions do not have a central strength member). The cables are available in and constructions with bend insensitive single-mode, 62.5/125 µm OM1, 50/125 µm OM2,, or 50/125 µm OM4 fiber. All fiber types other than OM1 are bend insensitive. Standard jacket colors are orange for 62.5/125 µm OM1 and 50/125 µm OM2, aqua for and 50/125 µm OM4, and yellow for singlemode BIF. Other jacket colors are available upon request. Standards Compliance: TE Connectivity cables are designed and tested to conform to the fiber and cable performance requirements of TIA 568, ISO 11801, Telcordia GR-409-CORE and ICEA-596 Standards. All cables have UL or ETL fire safety listings to either OFNR (UL-1666/CSA FT4) or OFNP (NFPA-262/UL 910/CSA FT6). Cable Print: Cables will be marked every two feet with: TE CONNECTIVITY <fiber count> <fiber type> <flame rating> MM/YY SO<shop order number> FEET 2014 Tyco Electronics Corporation, a TE Connectivity Ltd. Company. All Rights Reserved. TE Connectivity, and TE connectivity (logo) are trademarks. Other logos, product and/or company names might be trademarks of their respective owners. This specification is subject to change without notice. 1 of 7

s: s/unit 6 1 6 8 1 8 Type 62.5/125 µm OM1 Orange 1-1553307-1 50/125 µm OM2 Orange 1-1553307-2 Aqua 3-1553307-9 50/125 µm OM4 Aqua 4-1553307-9 Single-mode BIF Yellow 7-1553307-3 Orange 1-1553308-1 Green 2-1553308-1 62.5/125 µm OM1 Red 5-1553308-1 Black 6-1553308-1 Yellow 7-1553308-1 Violet 8-1553308-1 Orange 1-1553308-2 Blue 1553308-2 Brown 3-1553308-2 Slate 4-1553308-2 50/125 µm OM2 Red 5-1553308-2 Yellow 7-1553308-2 Violet 8-1553308-2 Rose 9-1553308-2 Aqua 1-1553308-9 Aqua 3-1553308-9 Orange 1-1553308-4 Red 5-1553308-4 50/125 µm OM4 Aqua 4-1553308-9 Yellow 7-1553308-3 Single-mode BIF Slate 4-1553308-3 White 2-1553308-8 62.5/125 µm OM1 Orange 1-1553309-1 50/125 µm OM2 Orange 1-1553309-2 Aqua 3-1553309-9 Orange 1-1553309-4 50/125 µm OM4 Aqua 4-1553309-9 Single-mode BIF Yellow 7-1553309-3 62.5/125 µm OM1 Orange 1-1553310-1 50/125 µm OM2 Orange 1-1553310-2 Aqua 3-1553310-9 Green 2-1553310-4 Yellow 7-1553310-4 50/125 µm OM4 Aqua 4-1553310-9 Single-mode BIF Yellow 7-1553310-3 REV F 2 of 7

s/unit 12 1 12 Type 62.5/125 µm OM1 Orange 1-1553311-1 50/125 µm OM2 Orange 1-1553311-2 Aqua 3-1553311-9 Blue 1553311-4 50/125 µm OM4 Aqua 4-1553311-9 Single-mode BIF Yellow 7-1553311-3 62.5/125 µm OM1 Orange 1-1553312-1 Orange 1-1553312-2 Blue 1553312-2 Brown 3-1553312-2 Slate 4-1553312-2 50/125 µm OM2 Red 5-1553312-2 Yellow 7-1553312-2 Violet 8-1553312-2 Rose 9-1553312-2 Aqua 1-1553312-9 Aqua 3-1553312-9 Blue 1553312-4 Red 5-1553312-4 Aqua 4-1553312-9 50/125 µm OM4 Orange 1-1553312-5 Black 6-1553312-5 Yellow 7-1553312-3 Single-mode BIF Slate 4-1553312-3 Red 5-1553312-3 Black 6-1553312-3 REV F 3 of 7

s/unit 24 1 24 24 2 12 24 4 6 36 6 6 Type 62.5/125 µm OM1 Orange 1-1553313-1 50/125 µm OM2 Orange 1-1553313-2 Aqua 3-1553313-9 50/125 µm OM4 Aqua 4-1553313-9 Single-mode BIF Yellow 7-1553313-3 62.5/125 µm OM1 Orange 1-1553314-1 50/125 µm OM2 Orange 1-1553314-2 Aqua 3-1553314-9 Orange 1-1553314-4 Green 2-1553314-4 Red 5-1553314-4 Aqua 4-1553314-9 Orange 1-1553314-5 Brown 3-1553314-5 50/125 µm OM4 Red 5-1553314-5 Black 6-1553314-5 Yellow 7-1553314-5 Violet 8-1553314-5 Single-mode BIF Yellow 7-1553314-3 62.5/125 µm OM1 Orange 1-1553315-1 50/125 µm OM2 Orange 1-1553315-2 Aqua 3-1553315-9 Orange 1-1553315-4 50/125 µm OM4 Aqua 4-1553315-9 Single-mode BIF Yellow 7-1553315-3 62.5/125 µm OM1 Orange 1-1553316-1 50/125 µm OM2 Orange 1-1553316-2 Aqua 3-1553316-9 50/125 µm OM4 Aqua 4-1553316-9 Single-mode BIF Yellow 7-1553316-3 62.5/125 µm OM1 Orange 1-1553317-1 50/125 µm OM2 Orange 1-1553317-2 Aqua 3-1553317-9 Orange 1-1553317-4 50/125 µm OM4 Aqua 4-1553317-9 Single-mode BIF Yellow 7-1553317-3 62.5/125 µm OM1 Orange 1-1553318-1 50/125 µm OM2 Orange 1-1553318-2 Aqua 3-1553318-9 50/125 µm OM4 Aqua 4-1553318-9 Single-mode BIF Yellow 7-1553318-3 62.5/125 µm OM1 Orange 1-1553319-1 50/125 µm OM2 Orange 1-1553319-2 Aqua 3-1553319-9 50/125 µm OM4 Aqua 4-1553319-9 Single-mode BIF Yellow 7-1553319-3 62.5/125 µm OM1 Orange 1-1553320-1 50/125 µm OM2 Orange 1-1553320-2 Aqua 3-1553320-9 50/125 µm OM4 Aqua 4-1553320-9 Single-mode BIF Yellow 7-1553320-3 REV F 4 of 7

s/unit 48 4 12 72 6 12 96 8 12 144 12 12 Type 62.5/125 µm OM1 Orange 1-1553321-1 50/125 µm OM2 Orange 1-1553321-2 Aqua 3-1553321-9 50/125 µm OM4 Aqua 4-1553321-9 Single-mode BIF Yellow 7-1553321-3 62.5/125 µm OM1 Orange 1-1553322-1 50/125 µm OM2 Orange 1-1553322-2 Aqua 3-1553322-9 Green 2-1553322-4 Red 5-1553322-4 50/125 µm OM4 Aqua 4-1553322-9 Black 6-1553322-5 Single-mode BIF Yellow 7-1553322-3 62.5/125 µm OM1 Orange 1-1553323-1 50/125 µm OM2 Orange 1-1553323-2 Aqua 3-1553323-9 50/125 µm OM4 Aqua 4-1553323-9 Single-mode BIF Yellow 7-1553323-3 62.5/125 µm OM1 Orange 1-1553324-1 50/125 µm OM2 Orange 1-1553324-2 Aqua 3-1553324-9 Blue 1553324-4 Green 2-1553324-4 Red 5-1553324-4 Yellow 7-1553324-4 50/125 µm OM4 Aqua 4-1553324-9 Single-mode BIF Yellow 7-1553324-3 62.5/125 µm OM1 Orange 1-1553325-1 50/125 µm OM2 Orange 1-1553325-2 Aqua 3-1553325-9 50/125 µm OM4 Aqua 4-1553325-9 Single-mode BIF Yellow 7-1553325-3 62.5/125 µm OM1 Orange 1-1553326-1 50/125 µm OM2 Orange 1-1553326-2 Aqua 3-1553326-9 50/125 µm OM4 Aqua 4-1553326-9 Single-mode BIF Yellow 7-1553326-3 62.5/125 µm OM1 Orange 1-1553327-1 50/125 µm OM2 Orange 1-1553327-2 Aqua 3-1553327-9 50/125 µm OM4 Aqua 4-1553327-9 Single-mode BIF Yellow 7-1553327-3 62.5/125 µm OM1 Orange 1-1553328-1 50/125 µm OM2 Orange 1-1553328-2 Aqua 3-1553328-9 50/125 µm OM4 Aqua 4-1553328-9 Single-mode BIF Yellow 7-1553328-3 Black 6-1553328-3 REV F 5 of 7

Hybrid Distribution Cables: s/unit 8 1 8 12 1 12 24 4 6 24 2 12 24 2 12 36 6 6 Number Of Type s 4 Single-mode BIF 4 4 Single-mode BIF 8 50/125 µm OM2 6 Single-mode BIF 6 50/125 OM3 12 50/125 OM3 24 62.5/125 µm OM1 24 62.5/125 µm OM1 Outer Black 1553471-8 Black 1553263-8 Aqua 3-1664404-9 Orange 4-1664086-1 Orange 4-1664087-1 Orange 4-1664084-1 Orange 4-1664085-1 Aqua 3-1664406-9 Orange 4-1664088-1 Orange 4-1664089-1 72 6 12 24 Single-mode BIF 48 62.5/125 µm OM1 24 Single-mode BIF 48 62.5/125 µm OM1 48 Single-mode BIF 24 Orange 4-1664090-1 Orange 4-1664091-1 Black 1553334-8 Note: Hybrid cables are constructed in order of core size from smallest to largest (single-mode fibers taking the first positions, followed by multimode). Single-mode subunits will have a yellow subunit jacket. Multimode OM1 and OM2 subunits will have an orange subunit jacket. Multimode OM3 and OM4 subunits will have an aqua jacket. REV F 6 of 7

Mechanical Specifications: (units x fibers/unit) 6 (1x6) 8 (1x8) 12 (1x12) 24 (1x24) 24 (2x12) 24 (4x6) 36 (6x6) 48 (4x12) 72 (6x12) 96 (8x12) 144 (12x12) O.D. Sub Unit O.D. Minimum Bend Radius Install Long Term Nominal Weight kg/km (lbs/1000ft) Rated Tensile Load Install N (lbf) Long Term N (lbf) OFNR 5.4±1.2 (0.21±.05) 114 (4.5) 57 (2.2) 29 (19) 660 (150) 198 (45) OFNP 4.8±1.0 (0.19±.04) 110 (4.3) 55 (2.2) 24 (16) 440 (100) 132 (30) OFNR 5.8±1.3 (0.23±.05) 136 (5.4) 68 (2.7) 24 (16) 660 (150) 198 (45) OFNP 5.0±0.8 (0.20±.03) 110 (4.3) 55 (2.2) 26 (17) 440 (100) 132 (30) OFNR 6.3±1.0 (0.25±.04) 128 (5) 64 (2.5) 37 (25) 660 (150) 198 (45) OFNP 5.8±0.8 (0.20±.03) 128 (5) 64 (2.5) 46 (31) 440 (100) 132 (30) OFNR 8.0±1.3 (0.31±.05) 178 (7) 89 (3.5) 61 (41) 1320 (300) 396 (90) OFNP 7.7±1.0 (0.30±.04) 168 (6.6) 84 (3.3) 69 (46) 660 (150) 198 (45) OFNR 7.4±1.4 x 13.1±2.0 (0.29±.06 x 0.52±.08) 5.7±0.8 (0.23±.03) 284 (11.2) 142 (5.6) 87 (58) 1320 (300) 396 (90) OFNP 7.1±0.9 x 12.7±1.7 (0.28±.04 x 0.50±.07) 5.6±0.8 (0.22±.03) 264 (10.4) 132 (5.2) 92 (62) 660 (150) 198 (45) OFNR 13.4±0.8 (0.53±.03) 4.4±0.6 (0.17±.02) 275 (10.8) 137 (5.4) 180 (121) 1320 (300) 396 (90) OFNP 12.7±1.6 (0.50±.06) 4.5±0.3 (0.18±.01) 266 (10.5) 133 (5.2) 200 (134) 660 (150) 198 (45) OFNR 16.3±1.3 (0.64±.05) 4.4±0.6 (0.17±.02) 342 (13.5) 171 (6.7) 220 (148) 1320 (300) 396 (90) OFNP 16.2±1.1 (0.64±.04) 4.5±0.3 (0.18±.01) 327 (12.9) 164 (6.4) 255 (171) 660 (150) 198 (45) OFNR 16.0±2.0 (0.63±.08) 5.6±0.7 (0.22±.03) 350 (13.8) 175 (6.9) 250 (168) 1320 (300) 396 (90) OFNP 15.6±1.7 (0.61±.07) 5.4±0.5 (0.21±.02) 312 (12.3) 156 (6.1) 202 (136) 660 (150) 198 (45) OFNR 19.1±1.0 (0.75±.04) 5.4±0.4 (0.21±.02) 386 (15.2) 193 (7.6) 301 (202) 1320 (300) 396 (90) OFNP 18.9±1.7 (0.74±.04) 5.4±0.4 (0.21±.02) 386 (15.2) 193 (7.6) 316 (212) 660 (150) 198 (45) OFNR 23.3±1.5 (0.92±.06) 5.4±0.4 (0.21±.02) 462 (18.2) 231 (9.1) 433 (291) 1320 (300) 396 (90) OFNP 22.6±1.8 (0.86±.07) 5.4±0.4 (0.21±.02) 448 (17.6) 224 (8.8) 466 (313) 660 (150) 198 (45) OFNR 25.2±1.8 (0.99±.07) 5.4±0.4 (0.21±.02) 514 (20.2) 257 (10.1) 461 (310) 1320 (300) 396 (90) OFNP 24.2±2.0 (0.95±.08) 5.4±0.4 (0.21±.02) 514 (20.2) 257 (10.1) 474 (319) 660 (150) 198 (45) Performance Characteristics: Maximum Attenuation 62.5/125 µm OM1 50/125 µm OM2 OM3 OM4 Single-mode (1310nm/1550nm) 3.5/1.2 db/km 3.5/1.5 db/km 3.0/1.0 db/km 3.0/1.0 db/km 0.5/0.5 db/km OFL Bandwidth 200/500 MHz km 500/500 MHz km 1500/500 MHz km 3500/500 MHz km Not Applicable 850nm Effective Modal Bandwidth 10 Gigabit Ethernet at 850nm Maximum Distance Specification Temperature s: Not Applicable Not Applicable 2000 MHz km 4700 MHz km Not Applicable 33m 82m 300m 550m Not Applicable TIA-492AAAA A1b TIA-492AAAB A1a.1 TIA-492AAAC A1a.2 TIA-492AAAD A1a.3 UL/NEC Operation Installation Storage/Shipping ITU-T G.657.A1 (OFNP) (OFNR) 0 C to +70 C (+32 F to +158 F) -20 C to +70 C (-4 F to +158 F) 0 C to +60 C (+32 F to +140 F) -10 C to +60 C (14 F to +140 F) -40 C to +70 C (-40 F to +158 F) REV F 7 of 7