OPEN PATH DETECTION OF ACROLEIN LEAKS

Similar documents
UV Sentry. Cost Effective Perimeter & LDAR Monitoring. ...Precise, Species Specific Fugitive Emissions Quantification

SENTRY-MS Mono-static Multi-gas Open Path Analyzer

SEC SIGNATURE ETO MONITOR TRAINING SENSOR ELECTRONICS CORPORATION

New Features TDLS 200. The Process TDLS Solution. Tunable Diode Laser Spectroscopy (TDLS) Analyzer.

Mass Sensors, Inc. Profile. Applications. Technology Baur Blvd, St. Louis, MO (314)

Technical specifications of FT-IR Spectrometer

Updated Leak Detection & Location Technology

Laser Analyzers for NH3 Safety Monitoring and Leak Detection

PUV, PIR and PFO Series BROCHURE

University of California Santa Barbara Department of Chemistry and Biochemistry Optical Characterization Facility. Safe operations manual

Toxic Gas Detection. Model F12. Toxic Gas Detection

An FT-NIR Primer. NR800-A-006

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000

Infrared Thermometer with 12:1 Distance-to-Sight Ratio and Temperature Alarm

RS Pro Infrared Temperature Sensor

Model D12-IR. Digital Gas Transmitter...

E²M. Innovation with Integrity. Enhanced Environmental Mass Spectrometer. Safety & Security

Recalibrate the way you look at gas detection

FS-200. Model. Instruction Manual. Infrared Food Thermometer. reedinstruments. www. com

Compact Sensor Heads for In-situ and Non-Contact Standoff Gas Sensing using TDLAS in Harsh Environments

Gas Detection in Process Industry The Practical Approach

Key Features. General Description

CS744 Series: Carbon/Sulfur by Combustion

ANNEX I. Technical specifications for: Supply of various Trace Explosive Detection Systems

Laser Level Measurement Products. Introducing the New LLT100

Advantages / Characteristics

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

Maxline 2 Thermal Imaging Solutions for Manufacturing

SAFETY MANUAL. PointWatch Eclipse Infrared Hydrocarbon Gas Detector Safety Certified Model PIRECL

CONTAMINATION CONTROL FOR ELECTRONIC AND SEMICONDUCTOR APPLICATIONS

JAMES MOODY IM FLASH LIFE SAFETY AHJ

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

Dependable Solutions for Gas Detection

SIEMENS ULTRAMAT 6 IR CARBON MONOXIDE ANALYZER METHOD VALIDATION FOR TESTING CARBON MONOXIDE IN NITROGEN, NF

MIR Spectroscopic Sensing. IQCLSW 19th Sept Simon Nicholson Sales Director Cascade Technologies

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Application Note CBRNE Stand-Off Detection of Toxic Industrial Chemicals in Industrial Complexes Using RAPIDplus

Dual Laser InfraRed (IR) Thermometer

Introduction to the Fusion TOC Analyzer

Mid-Infrared Laser based Trace Gas Sensor Technologies: Recent Advances and Applications OUTLINE. Mar. 23, Houston, TX

Beam-A-Temp Portable Infrared Thermometer Measures up to 1832 F/1000 C with 50:1 distance to target ratio. Specifications

1.1 Definitions of alert icons. For your safety

Dual Laser InfraRed (IR) Thermometer

High Temperature InfraRed Thermometer with Laser Pointer

Laser Safety and Classification Full Version (CA-1110) Advanced Version (CA-1111) Basic Version (CA-1112)

11/22/2013. Where are we now? How did we get here? MSDS Sheets. CA MSDS Standard. Right To Know. Director s List. T8 CCR 5194 Hazard Communication

ice 3000 Series Atomic Absorption Spectrometers Flame and furnace AAS analysis for routine laboratories

SPECIFICATIONS PARTICLE SENSOR KS-41B Higashimotomachi, Kokubunji, Tokyo , Japan

On-site Detection of Siloxanes and other unwanted VOCs in Landfill/Sewage/Biogas using Gas Chromatograph-Ion Mobility Spectrometer (GC-IMS)

Products and performance

Monitoring for CWAs and TICs in Homeland Security Applications. Charles M. Phillips MKS Instruments Inc., Andover, MA 01810

ice 3000 Series Atomic Absorption Spectrometers Flame and furnace analysis for routine laboratories

Standoff CWA/TIC Detection. Innovation with Integrity. Toxic Gas/Vapour Threat Mitigation RAPIDplus CBRNE

MicroRay IR-100 NEW. Inspection MicroRay IR-100

Milano, 25 novembre 2015

North Dakota State University Laser Safety

Temperature Data Logging

IRT2 Dual Laser IR Thermometer - User Guide

Class 1 laser beam sensor safe for your eyes

VICOTEC450 EXTRACTIVE VISIBILITY MEASURING DEVICES EXTRACTIVE VISIBILITY MEASUREMENT FOR INCREASED SAFETY IN TUNNELS

SafEye OPEN-PATH GAS DETECTION SYSTEM XENON 700. We INVENTED it... We PERFECTED it! Patent No. US 5,281,816; US 6,061,141; EP

SAFETY MANUAL. Electrochemical Gas Detector GT3000 Series Includes Transmitter (GTX) with H 2 S or O 2 Sensor Module (GTS)

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

E11 Tests of trace gas concentration multicomponent. monitoring system

Class 1 laser beam sensor safe for your eyes

Laser Collimated Beam Sensor

Stand-off Detection of Trace Explosives by Infrared Photothermal Imaging. Trace Contamination

Contamination Control for Electronic and Semiconductor Applications

A. General Safety LAB/ROOM: INSPECTED BY: DATE:

Multi-layered Perimeter Protection Systems Quality detection systems for high security sites

Company facts. ! Photoacoustic Spectroscopy (PAS) and! Fourier Transform InfraRed (FTIR) principle

Class 1 laser beam sensor safe for your eyes

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

SEC Signature Process Gas Analyzer

LIQUIDATOR Electronic Ionization System

Product Specification

SAFETY MANUAL. Multispectrum IR Flame Detector X3301

Figure 1-1 Furnace Front Elevation

GASGUARD SO2 Sulfur Dioxide Sensor OPERATING & INSTALLATION MANUAL

Using the DewMaster Deluxe Dew Point/ Humidity Hygrometer

IRtech. E instruments. IRtech Radiamatic IR20 LS series. Infrared Technology

PRODUCT INFORMATION. GM901 Carbon Monoxide Gas Analyzers CO MEASUREMENT FOR EMISSION MONITORING AND PROCESS CONTROL. In-situ Gas Analyzers

Oxygen Deficiency Monitor and Oxygen Analyzers. Oxygen Sensors for 0-25% and ppm

Laser Gas Detection OEM Gas Sensing Solutions

HPLC Column Ovens and Temperature Controllers

Contamination Control for Life Science Applications

AUTOMOTIVE REFRIGERANT ANALYZER OPERATION MANUAL. Analyzer Part Number: 68941

White Paper. Critical Considerations for Monitoring Low Levels of Hydrogen Sulfide. by Jacob Spector and Kirk Johnson

Redefining aerosol leak detection with speed, accuracy & reliability.

LASER SAFETY. Class 2 and 2a - low power, low risk Class 2 and 2a lasers have low power and emit visible light. They will cause harm if viewed

E1000 Portable gas detector

Motorised Infrared Optical Beam Smoke Detector. User Guide

Passive Standoff FTIR Detectors as Transducers. Background From radiation to information

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

LINEAR HEAT DETECTION CABLE DURÁN-SAFE

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

LI-830 and LI-850 Gas Analyzers. For Continuous Monitoring Applications

A New Standard of Excellence

Transcription:

APPLICATION NOTE AN-N07-01 OPEN PATH DETECTION OF ACROLEIN LEAKS Introduction Block Engineering s LaserWarn sensor is a real time, open path mid IR chemical analyzer. LaserWarn uses patented next generation Quantum Cascade Lasers (QCLs) to detect chemical threats, leaks, and fugitive emissions over thousands of square feet. Utilizing eye safe lasers, this instrument has both indoor and outdoor applications such as fence-line monitoring or an environmental safety tripwire. LaserWarn operates continuously in the mid infrared to deliver real time chemical identification and quantification of fugitive gases in less than 1 second. As shown in this Application Note, LaserWarn can detect acrolein leaks at concentrations of around 1 ppm. Acrolein and Industrial Applications Acrolein, or propenal (CAS# 1107-02-8: C 3H 4O), is an unsaturated aldehyde produced by burning of oils and fats. Acrolein has two important industrial uses, as a chemical precursor and as a powerful biocide. Acrolein is largely produced to synthesize acrylic acid and DL-methionine: an important amino acid used as an industrial feed supplement. Acrylic acid is a key component in plastic and polymer chemistries necessary to manufacture plastics, coatings, adhesives and other paint-type compounds. In other applications, acrolein is used by oilfields and irrigation channels as a powerful biocide. It is effective at mediating algae, mollusks, bacteria, and other living species found in processes that require water recirculation such as cooling water towers, water treatment ponds, irrigation channels, surface equipment, water injection systems and injection wells. Specifically to the oil and drilling business, bacteria can be destructive to drilling efforts due to H 2S formation by sulfate reducing bacteria metabolism, biofouling, iron sulfide scaling, microbiological driven corrosion, formation face damage and contamination of feedstock from sulfite generation. Acrolein is a powerful solution to these problems since it not only is oil-permeable and biofilm permeable allowing easy mitigation of bacterial colonies at the site, but it also acts as a H 2S scavenger and an iron-sulfide dissolver. Because acrolein is so widely used in the oil drilling and other industries it poses significant health and safety risks. Acrolein is classified as a severe poison, severely flammable, extremely corrosive, possible human carcinogen and a potential peroxide former. Despite the dangerous nature of this chemical, the benefits outweigh the risks of using acrolein in industrial settings so preventative measures have to be implemented to reduce employee exposure. To date OSHA states that the total permissible exposure limit (PEL) should not exceed 0.1 ppm total weighted average (TWA) or 0.3 ppm for short term exposure. In order to comply and keep workforces safe from this toxic chemical, industries need to find reliable monitoring systems. LaserWarn offers a solution to open-path fence-line monitoring with the ability to detect chemical leaks in real time. This real-time analysis can be used to alert workers to immediately leave the targeted area as well as supply important information needed to resolve and fix the leak.

LaserWarn as a Chemical Leak Monitoring Solution LaserWarn utilizes patented QCL lasers capable of scanning the mid infrared region to create an openpath mid IR spectrometer capable of identification and quantification of complex chemical species. The QCLs contained within the LaserWarn system produce continuous spectra of all chemicals detected within the monitoring path and spectral range of the system. The spectra collected is then analyzed using proprietary algorithms embedded within the control electronics of the machine. The results are displayed to the user as an easy to read quantification of all chemical species present in the currently monitored environment. The LaserWarn chemical monitoring system is configurable in either an indoor or outdoor setting depending on application requirements. For outdoor monitoring the system is enclosed within a NEMA enclosure, capable of temperatures between -40 and 50 Celsius and is self-contained within one box (10 x 37 x 14 LxWxH). The LaserWarn emits a laser capable of a 500 m stand-off distance to a retro-reflector mirror for a total monitoring length of 1 km. The LaserWarn communicates directly with a Digital Control System (DCS) over Modbus via TCP/IP or using a Google Chrome GUI. The analyzer is able to communicate to a local alarm system via a Modbus command when a certain concentration threshold is reached. The analyzer itself does not have an internal alarm system but it does have the capability to communicate and trigger an alarm at the installation site through a Modbus communication register. Each system is designed with an application specific library of detectable gases (contact Block for your individual gas monitoring needs). The system, once aligned, is ready for continuous 24/7 monitoring. Each system is also equipped with an internal adjustable polystyrene reference, beam control electronics for remote beam fine tuning, and a fillable gas cell for other referencing needs. The system is factory calibrated but a reference is necessary to adjust they system to account for changes in humidity and ambient air changes. The polystyrene and gas bump cell are used to monitor and evaluate the internal reference but are not necessary for daily monitoring purposes. LaserWarn is designed with unique software that displays real-time spectra of all detected chemical species as well as quantification for each detected analyte. Each unit is supplied with a custom library of 5 gases specific to each customer s needs and is field upgradeable. To test responsivity and effectiveness of LaserWarn s ability to monitor acrolein the system was validated at Block Engineering in Marlborough, MA. Using a permeation tube, different amount of acrolein was monitored and tested using the QCL mid-ir laser spectrometer system. The experimental setup had a permeation oven at the ideal temperature specified by the tube manufacturer. A fixed flow of nitrogen was passed through the oven at a steady status to ensure consistent release rate. AN-N07-01: OPEN PATH DETECTION OF ACROLEIN LEAKS PAGE 2 OF 5

Concentration (ppm) Three different tests were performed. Since acrolein is toxic, a gas cell was used to capture the gas generated. The set up illustrated in Figure 1 was plumbed to contain and ensure proper disposal of the toxic gas: Figure 1: Experimental design of gas cell and LaserWarn interface To monitor response time and repeatability the flow control was used to alternate between acrolein and 100% N 2. Data was collected continuously and the following graph was generated displaying the response and repeatability of the system: Figure 2: Responsivity and repeatability study of LaserWarn with acrolein 200 175 150 125 100 75 50 25 0 LaserWarn Acrolein, Repeatability test 3.5m Pathlength, 4 second average 167 165 167 AN-N07-01: OPEN PATH DETECTION OF ACROLEIN LEAKS PAGE 3 OF 5

The above LaserWarn data shows a ~1% error associated with repeatability. This measurement was performed in triplicate to eliminate any sort of experimental bias. It was also demonstrated that the system is able to detect immediate introduction of the acrolein. Due to the toxicity of acrolein, the test was performed in a cell and the t90 1 time was determined to be 28 seconds with a 4 second average. The response timing and averaging was direct related to the delivery system, not the performance of the instrument. In the field, this number is not relevant, but for experimental design and competency of the model, the software was able to record the accurate saturation of the cell within 7 sample scans (28 second measurement with a 4 second scan interval). This number shows the design of the experimental cell and gas chamber is reliable and has reached a steady state. The steady state measurement of the gas cell and chamber is important to ensure that all data recorded is consistent and experimental error is minimized. Linearity in response is a very important parameter in spectroscopic measurements as well. To study the linearity of the response of the LaserWarn system the concentration of acrolein was increased over time and data points were taken (see Figure 3): Figure 3: LaserWarn linearity study with varying concentrations of acrolein 1 t90 is a measurement of the response of a system. Gas detection is often an exponential concentration increase; therefore, the t90 is a measurement that describes the response time of the system necessary to detect a 90% of the expected concentration. AN-N07-01: OPEN PATH DETECTION OF ACROLEIN LEAKS PAGE 4 OF 5

PPM The data shows a very linear correlation between the LaserWarn detection and response to the changing acrolein concentration. The R 2 value supports the fit of the line and the accuracy of the repeat measurements. Systematic noise is an important parameter that needs to be addressed when validating a spectroscopic technique. To assess the noise of each measurement the concentration of analyte was adjusted and measured over time to see the standard deviation and the noise associated with each measurement. The chart in Figure 4 was prepared to study the noise of each measurement: Figure 4: timed measurements of known concentrations of acrolein to determine signal noise 250 LaserWarn Acrolein Noise Test 4 second average 200 Noise 0.9 ppm (2XSTDEV) 150 100 50 0 11:19:4111:22:3411:25:2611:28:1911:31:1211:34:0511:36:5811:39:5011:42:4311:45:3611:48:29 Each measurement was taken over 5 minute intervals. The permeation system was set at a steady state and the sample line was diluted with extra carrier N 2 gas. By diluting the system post-sample delivery system we were able to limit noise from a varying permeation system and the noise can be directly correlated to the detection system. After taking a timed average and standard deviation for each concentration change it was noted that the average standard deviation is less than 0.5 ppm and the noise on the system is approximately twice the standard deviation: below 1 ppm. With a low standard deviation and low noise, the LaserWarn system can detect changes in concentrations, above the detection limit, less than 1 ppm. In conclusion, the LaserWarn system is capable of making fast, repeatable and precise measurements of acrolein. This study supports the use of LaserWarn as a fence-line monitoring option for fugitive acrolein emissions and leak detection. AN-N07-01: OPEN PATH DETECTION OF ACROLEIN LEAKS PAGE 5 OF 5