BAXTER: FACTOR VII 600 IU (Plasma Derived)

Similar documents
Administration of AMBISOME Using the GemStar Pump

MINIMED 670G SYSTEM CHANGING THE MINIMED MIO INFUSION SET QUICK REFERENCE GUIDE

MINIMED 670G SYSTEM CHANGING THE QUICK-SET INFUSION SET QUICK REFERENCE GUIDE

MINIMED 670G SYSTEM CHANGING THE MINIMED SILHOUETTE INFUSION SET QUICK REFERENCE GUIDE

Troubleshooting your BAXJECT II Needle-less Transfer device

Caring for your Drain Tube at Home

Physician s order will specify the level of underwater seal, typically -10 to 20 centimetres (cm) and will identify if suction is to be applied.

Methods of solid phase extraction. Methods of solid phase extraction

Agilent Vac Elut SPS 24 Manifold User Guide

Speed switch moves up or down to adjust speed. Fast. Medium

ACME DIAGNOSTICS STANDARD OPERATING PROCEDURE

How To Use Spawn Bags

ON TRACK Reprocessing In-service / Competency for CF/PCF/GIF Endoscopes (EVIS, EXERA, EXERA II)

U S E R G U I D E. Home Respiratory Equipment Cleaning Guide. Health Information

Activity Instructions

SERRES SUCTION BAG SYSTEM MANUAL

ALLERGEN MIXING ASSISTANT

Introduction. Sharps. Working Safely with Sharps at UAB (OHS_HS255) Objectives. Defined

1a Installing Optional Soap Dispenser for A/O Drain Units. A Place the upper tie bar on top of the. B Insert the tie rod assembly through the

PASTEURIZED MILK CONTAINERS, CLOSURES AND PACKAGING IMS #22 (PMC) [Unless otherwise stated all tolerances are ±5%] 1. Laboratory Requirements

Attendance Sheet. (List each model reviewed during this session) Print Name Signature Title. Print Name Signature Title.

ELITE (110V) (220V)

CPAP Washbasin Manual

2. Occupational safety / Security Waste disposal/waste, disposal bags

GAS CHROMATOGRAPHY PURDUE UNIVERSITY INSTRUMENT VAN PROJECT. DEMYSTIFICATION ACTIVITY FOR THE GAS CHROMATOGRAPH (Revised: ) INTRODUCTION

OPERATING INSTRUCTIONS FUSION MODEL 610 DIGITAL DISPENSING SYSTEM

HydroFlux Welder Torch System T0-102 / T0-103

How to use your live liquid culture syringe.

SRI 8610C GC for PCB in Transformer Oil Analysis November 2014

Using the Lely Robot Sampler CanWest DHI Robot Manual

Ink Degasser for Pro-HP Bulk System Installation and Operation Manual

Precision Fluid Dispenser TS9150 USER GUIDE

How To Use Spawn Bags

G.I. Procedures. Handbook

Environmental Protection November 1993 Agency Solid Waste and Emergency Response (5305) Disposal Tips for Home Health Care

Fermentor, 15-L STANDARD OPERATING PROCEDURE

Simulator Intravenous Arm (Two arm and circulation pump set)

Tips. Tips for Successful Vacuum Packaging. Tips on Sealing a Bag. Tips on Removing Air from a Bag. Tips on Storage

INSTRUCTIONS EVIS EXERA II DUODENOVIDEOSCOPE

PDMS Casting Station Supplies

Laboratory Techniques

USER GUIDE. Hot Water Dispenser. KA-HWD02 Series. Contents ,

Radioactive In Situ Hybridization Protocol (HBMI Core University of Rochester Medical Center)

VENDING PROVEN HYGIENE & CLEANING FOR WATER COOLERS. Performance Focus. Recommended Products

Effective Date: 0 8 / 1 0 / 1 7. Replaces: 08/11/16. Formulated:1997 SPECIAL (MEDICAL) WASTE MANAGEMENT

Ref r esher / I n - Service Manual

PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN COMPANION ANIMAL VETERINARY CLINICS/HOSPITALS

Assembly of a Microbial Fuel Cell

SYRINGES PROCESSING OF PRE-STERILIZED SYRINGES

PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN COMPANION ANIMAL VETERINARY CLINICS/HOSPITALS

WINDSHIELD REPAIR MANUAL SUPER CINCH

OWNER S INSTRUCTION & INFORMATION

Parasitic Cysts - Cryptosporidium and Giardia, Chemicals, Heavy Metals, Dissolved Salts, Offensive Tastes and Odours, Sediment, Dirt,

Tube Feeding by Pump UHN. Information for patients and families. Read this book to learn:

FS_IM_G.indd 1 14/02/ :44

CryoFit. Handling of Flow Cell and Capillaries. User Guide. Version 002

Aquamax KF Oil Evaporator. User Manual

150 SERIES VACUUM SEALING SYSTEM

Pool Weasel Vacuum Users Guide

Sanitise Syrup Lines & Valves. Taylor PH61 Cleaning every 14 days

Compresstome VF-300-0Z User Manual

Standard Operating Manual

Equipment Standard Operating Procedure Greg Allion and Kimberly Appel

INSTRUCTION MANUAL V8F145

Features. QuickStart. V1505/GameSaver Pro. Features of Your FoodSaver Appliance. Accessory Hose Storage. Accessory Hose.

Features. QuickStart. Professional III/GameSaver Turbo. Features of Your FoodSaver Appliance. Accessory Hose Storage (under lid) Manual Seal Button

PrimePour TM Operation Manual

OPERATING INSTRUCTIONS

Go Green in Your Home & Classroom!

OPERATING INSTRUCTIONS. Hearing Instrument Restoration System.

phd Countertop UltraWater Owner s Manual Delicious Great Tasting Antioxidant Alkaline Energized

L24TWS. Beverage Tower Kit Components. L24TWD Lynx Beverage Kits Model L24TWS Single Tower and L24TWD Double Tower

Determination of the enthalpy of vaporization of liquids

PREASSEMBLED SURGICAL WASH SET FOR DIDECO COMPACT ADVANCED Instructions for Use Product Designations: WS-55C, WS-125C, WS-175C, WS-225C DESCRIPTION:

PackardInfo.com. HOW TO: Rebuild a Trico Mag Nu Matic Vacuum Washer Pump. Introduction

RCM-77. Instruction Manual. G-Series Cooler. U.S. Patent No. 8,215,125 RECHARGE COLD MERCHANDISER

SISTEMAS PARA PRUEBAS DE ESTERILIDAD

USER MANUAL Model DWP-55/DWP-66

ULTIMATE REVERSE OSMOSIS SYSTEM

HP 1200,1300 CARTRIDGE REMANUFACTURING INSTRUCTIONS

Floormate Deluxe Let s get started

Safety In Chemistry. Identified Risks and Hazards

1909/1910 QUICK START GUIDE. Simpler Soil Water Samplers 02/2018. Fig. 1 - Model 1910LL Fig. 2 - Model 1910PL Fig. 3 - Model 1909L

FOR VETERINARY USE ONLY

Washroom care programs

12" Commercial Vacuum Sealer INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS

Tips. Tips for Successful Vacuum Packaging. Tips on Sealing a Bag. Tips on Removing Air from a Bag. Tips on Storage

Parents and Educators: use #CuriousCrew #CuriosityGuide to share what your Curious Crew learned!

How to Use Water Safely in Your Child Care Facility During a Boil Water Advisory

The Heidelberg Integrated 14 CO 2 Sampler Institute of Environmental Physics, ICOS CRL

1 of 7 12/22/2017, 3:28 PM. Composition

PEAK Platelet Rich Plasma System

POLOS Options

Parents and Educators: use #CuriousCrew #CuriosityGuide to share what your Curious Crew learned!

Page: Page 1 of 9 Author: Kristin Smith MAL Director: Dr. Peggy Borum FSHN Chair: Dr. Neil Shay

Technology choise Filling material and container Most suitable technology choice

INSTALLATION & SERVICE MANUAL

Pro Chem Hand Hygiene Guide

2006G2 OPERATING INSTRUCTIONS. 2006G2 Pressure-Vacuum Hand Pump July 2011 SOILMOISTURE

Transcription:

BAXTER: FACTOR VII 600 IU (Plasma Derived) STEP 1 Bring recombinant factor VII to room temperature before using. Choose a clean, dry, well-lit work area and lay out the following supplies Contained within the box: Bottle(s) of recombinant factor VII powder Bottle(s) of sterile water Double ended transfer needle (pink) Filter needle (clear) Needle (yellow) Aeration needle Butterfly needle Disposable syringe (do not use, not Luer Lock) Packaged separately: Sterile plastic Luer Lock syringe (10, 20 or 30 cc) Alcohol wipes STEP 2 Wash hands, under nails and forearms Use warm running water Use antibacterial soap from pump dispenser Dry hands with a paper towel Turn off taps with paper towel & discard STEP 3 Remove the caps from the bottles of FVII powder and sterile water. STEP 4 Clean the tops of the bottles with an alcohol swab. Allow to dry completely. DO NOT blow on the tops to speed up drying, this will contaminate them. STEP 5 Remove the protective cover from the double-ended transfer needle; the short end will be exposed. Insert the needle into the center of the stopper of the bottle of sterile water.

STEP 6 Remove the protective cover from the long end of the transfer needle. (TIP: It comes off easily, you do not need to hold transfer needle in place). Turn the sterile water upside down and, keeping the needle and bottle straight, stick the long end of the transfer needle into the center of the bottle of factor. Make sure not to push the needle hub against the stopper of the bottle as this may break the vacuum. See ALTERNATE STEP 7 if the vacuum is broken. STEP 7 After all of the sterile water has been drawn into the factor bottle, keeping the transfer needle in place, remove the sterile water bottle. This allows the vacuum to be released from the bottle of dissolved factor. DO NOT recap the transfer needle, remove and place it into the sharps container. STEP 8 Gently mix the product by rolling it in between hands until dissolved. STEP 9 Rewipe bottle(s) of factor with alcohol swab and allow to dry completely. Open the package containing the aeration needle and insert into the centre of the rubber stopper. This will collapse any foam. Remove the aeration needle and place into the sharps container. STEP 10 Open the package containing the sterile syringe. DO NOT touch the tip. Twist and pull the cap from the sterile filter needle exposing the end that will attach to the syringe. DO NOT touch the end. Attach the filter needle to the syringe, twisting to make sure that it is securely in place.

STEP 11 Pull the protective cover off of the filter needle. Pull back the plunger of the syringe and draw up air equal to the amount of factor solution. (e.g., 10 ml of air for 10 ml of factor solution). STEP 12 Insert the filter needle into the bottle of mixed factor solution and inject the air. Hold the plunger in as it will try to push back out. STEP 13 With the syringe plunger fully pushed in, turn the bottle and syringe upside down and slowly pull back on the plunger to withdraw ALL of the factor solution. As you are withdrawing the last bit of solution continue to pull back on plunger as you are withdrawing the needle from the bottle. STEP 14 When all of the factor solution has been withdrawn into the syringe, put the needle cover on, using only one hand ( Scooping up the cap, ensuring that the needle tip does not touch any surfaces). Remove filter needle and place in sharps container. STEP 15 Attach the syringe to the butterfly needle contained in the box of Factor VII for peripheral vein infusion. Holding the syringe and the needle pointing up, gently flick the syringe to move any air bubbles to the top and gently push on the plunger to remove the air. DO NOT push any factor solution out of the syringe.

STEP 16 Attach a blunt cannula for PORT infusion. STEP 17 Mark syringe with a piece of tape if using PORT. Administer slowly (through peripheral vein or Port-a-Cath ) at not more than 2 ml per minute (i.e., 10 ml over 5 minutes). Dispose of butterfly needle or winged infusion set in sharps container, remainder of waste to be disposed of in household garbage.

ALTERNATE STEP 7 STEP 7 Open the package containing the sterile syringe. DO NOT touch the tip. STEP 7B Attach a sterile #18 gauge needle to the syringe, twisting to make sure that it is securely in place. DO NOT touch the end. STEP 7C Remove the protective cover of the needle DO NOT throw out the cover. STEP 7D Pull back the plunger of the syringe to fill with air equal to the amount of sterile water (e.g., 10ml of air for 10ml of sterile water). STEP 7E Insert the needle into the center of the bottle of sterile water and inject air. Turn the sterile water upside down with the needle in place and draw back all of the water into the syringe. STEP 7F Remove the syringe and needle from the sterile water bottle and stick it into the factor bottle. Inject sterile water into the bottle of factor. Remove the syringe and needle from the bottle of factor. STEP 7G Put the needle cover on, using only one hand by scooping up the lid. Make sure that the needle does not touch any surfaces! STEP 7H Gently mix the liquid FVII by rolling the bottle in between hands until dissolved. GO TO STEP 8.