ALTERNATE METHODS FOR COMPLIANCE WITH THE 2003 INTERNATIONAL RESIDENTIAL CODE (IRC) & GARAGE FIRE SUPPRESSION SYSTEM

Similar documents
MONTECITO FIRE PROTECTION DISTRICT

ORDINANCE NO

(House Bill 849) Public Safety Rental Dwelling Units Carbon Monoxide Alarms

THE VILLAGE OF HAWTHORN WOODS PLUMBING CODE

New Construction Fire Inspection Process

RESIDENTIAL MULTI-USE FIRE SPRINKLER SYSTEMS PERMIT SUBMITTAL REQUIREMENTS

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

COMMERCIAL (IBC) FIRE ALARM SUBMITTAL GUIDE

FIRE SUPPRESSION SPRINKLER SYSTEM

Zurn Pex, Inc. Residential Fire Protection Presentation. PEX Plumbing, Radiant Heating and Residential Fire Protection Systems

FIRE PREVENTION AND PROTECTION*

International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures

Inspection of Fire Sprinkler Systems. NFPA 25, Inspection, Testing & Maintenance of Water Based Fire Protection Systems

Montgomery County Government Building and Codes Department 350 Pageant Lane, Suite 309 Clarksville, TN 37040

Fire Permit Application

Oxnard Fire Department 360 W. Second Street Oxnard, CA (805) Fax (805)

Florida Building Code Chapter 9 Fire Protection Systems Advanced Course

AUTOMATIC FIRE SPRINKLER SYSTEM STANDARDS Development Standard #4.1 (Commercial Installations)

FIRE SAFETY REQUIREMENTS FOR PRE RESIDENTIAL BUILDINGS OF THREE OR MORE STORIES (DOROTHY MAE ORDINANCE - NO. 158,963)

Moreno Valley Fire Department Fire Prevention Bureau. New and Existing Fire Alarm & Signaling Systems Guideline

CITY OF PALM BEACH GARDENS ORDINANCE NO. 12, 2002

SANTA CLARA COUNTY Winchester Blvd., Los Gatos, CA (408) (408) (fax)

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Engine Module Page 1 of 8 Annual Sprinkler System Inspection Revised

FIVE YEAR AUTOMATIC FIRE EXTINGUISHING SYSTEMS CERTIFICATION REPORT

ORDINANCE NUMBER

EXHIBIT A BE IT ORDAINED BY THE MAYOR AND THE CITY COUNCIL OF THE CITY OF BELLEVUE, NEBRASKA.

HIGH-RISE RETROFIT ORDINANCES - NO and NO

NASSAU COUNTY FIRE PROTECTION PERMIT APPLICATION

ST. LUCIE COUNTY FIRE DISTRICT FIRE PREVENTION CODE

Fire Sprinkler System Design and Installation Requirements

2430 Roman Forest Blvd. Ray Ricks Roman Forest, Texas Ordinance No. 215-A

SECTION WET PIPE FIRE PROTECTION SPRINKLER SYSTEM

BIRCH RUN TOWNSHIP SAGINAW COUNTY, MICHIGAN ORDINANCE NO ALARM SYSTEM ORDINANCE AMENDMENT

Public Notice of Amendment to New Shoreham General Ordinances Chapter 5 Fire Prevention and Protection New Article IV Fire Alarm Ordinance

DESIGN & CONSTRUCTION GUIDELINES

Bold items are particular to the City of Euless

ORDINANCE O-152. (B) Title. This ordinance shall be known as the City of Saginaw Outdoor and Open Burning Ordinance.

FIRE INSPECTION GUIDELINES FOR FOSTER GROUP HOME PARENTS Effective June 1, 2002, Update September 2011

Burnsville Fire Department 100 Civic Center Pky, Burnsville, MN Fire Marshal: FAX:

Florida Building Code 2010

BIRCH RUN TOWNSHIP SAGINAW COUNTY, MICHIGAN ORDINANCE # ALARM SYSTEM ORDINANCE

CubeSmart Gulf Breeze Storage AUTOMATIC FIRE SPRINKLER SYSTEM

VILLAGE OF DOWNERS GROVE Report for the Village Council Meeting

Fire Protection System Contractors and Systems. Submission of the Application for a Water-Based Fire Protection Inspector Permit

MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry

Fire Protection System Contractors and Systems. Submission of the Application for a Water-Based Fire Protection Inspector

ORDINANCE NO

ANN ARBOR CITY NOTICE ORDINANCE NO. ORD ALARM SYSTEMS

CITY OF PASADENA FIRE DEPARTMENT

MAINTENANCE AND SERVICE OF AUTOMATIC FIRE EXTINGUISHING SYSTEMS

University of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL

COBB COUNTY SCHOOLS /S&A % BID DOCUMENTS 2/18/11 SECTION SPRINKLER SYSTEM

CCCFPD RESIDENTIAL BUILDING REQUIREMENTS

WALL ESCUTCHEON PIPE SEAL WITH APPROVED FIRE CAULKING (SEE SPECIFICATIONS) NOTE: 12" 12" 24"

ORDINANCE AN ORDINANCE AMENDING THE HENDERSONVILLE MUNICIPAL CODE, TITLE 7, CHAPTER 2, FIRE CODE

West District Library Section Campeau Drive, Ottawa SPRINKLER SYSTEMS City of Ottawa Project No. CR Page 1 of 8

D. The work addressed in this section consists of a fire protection system, which may include coordination with one or more of the following:

a) Establishment of emergency procedures to be followed at the time of an emergency;

General Permit Information: Proposed Building Use: Commercial- Labor & Material Cost Code Edition:

Design & Construction Standards, Revised January

District of Sicamous. Fire Department Bylaw No. 126, Effective Date February 26, 1996

SPRINKLER ORDINANCE Town of Yarmouth, Maine Recodified: 1/15/98 Amended: 4/19/01 Amended: 6/18/15

University Design Standard Fire Alarm Systems

FIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University.

HOW COMMERCIAL FIRE PROTECTION SPRINKLER SYSTEMS REALLY OPERATE

SECTION : FIRE ALARM & DETECTION SYSTEMS

Sprinkler Permit Applications

SECTION 915 CARBON MONOXIDE DETECTION

A. Hydraulic calculations shall be prepared in accordance with Chapter 23 of NFPA 13 with the following exceptions:

ORDINANCE NO. Establishing Fire and Life Safety Requirements for Existing Multi-Family Residential Buildings Classified as Group R, Division Occupancy

S 2758 S T A T E O F R H O D E I S L A N D

C. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant.

Fire & Life Safety Supplemental Rules & Regulations for New Construction & Significant Remodels

ORDINANCE NUMBER~-07

Rancho Cucamonga Fire Protection District Prevention Bureau Standard

Minimum Standards for Engineers Practicing Fire Protection Engineering in the State of Oklahoma September 14, 2016

APPLICATION FOR Large Family Day Care Permit

SECTION WET-PIPE SPRINKLER SYSTEMS EASY RISER CHECK VALVE

Annual Report of Inspection, Testing & Maintenance of Automatic Sprinkler System

1.1 Refer to Section for General Mechanical Requirements. 1.3 Refer to Section for Pipe and Equipment Identification Requirements.

RESIDENTIAL FIRE SPRINKLER SYSTEMS POLICY

FIRE SUPPRESSION SYSTEM REVIEW APPLICATION 1. NEW PLAN REVIEW RESUBMITTAL

TECHNICAL DATA OBSOLETE. * Refer the Approval Chart on page 121c and Design Criteria on page 121d for FM approval requirements that must be followed.

Recommended Amendments to the 2015 International Existing Building Code North Central Texas Council of Governments Region

ORDINANCE NO

ORDINANCE NO NOW, THEREFORE, BE IT ENACTED BY THE CITY COUNCIL OF THE CITY OF FAIRBANKS, ALASKA, as follows:

FIRE PREVENTION CODE. conditions hazardous to life and property from fire, hazardous materials, or explosion.

2. Welding Materials and Procedures shall conform to the ASME Code.

BYLAW NO (CONSOLIDATED)

State Board of Examiners of Plumbing, Heating & Fire Sprinkler Contractors. Residential Fire Sprinkler Inspections

The definitions provided in , C.R.S., shall apply to these rules and regulations. The following additional definitions shall also apply:

BE IT ORDAINED BY THE BOARD OF DIRECTORS OF THE FENTON FIRE PROTECTION DISTRICT OF ST. LOUIS COUNTY, MISSOURI AS FOLLOWS:

ORDINANCE WHEREAS, this Ordinance is consistent with the City of Winter Garden Comprehensive Plan; and

SECTION WET-PIPE SPRINKLER SYSTEMS

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

SECTION : FIRE PROTECTION SYSTEMS

TECHNICAL DATA. * Refer the Approval Chart on page 120c and Design Criteria on page 120d for culus and FM approval requirements that must be followed.

Town of Florence Florence County, WI DRIVEWAY ORDINANCE

1.2 CODES AND REGULATIONS A. Sprinkler system design, equipment, materials, devices, and installation shall conform to the following:

APPENDIX H (DESIGN SUBMISSION CRITERIA)

Transcription:

ORDINANCE NO. cjdo44lj JJ -~ ALTERNATE METHODS FOR COMPLIANCE WITH THE 2003 INTERNATIONAL RESIDENTIAL CODE (IRC) 309.1.1 & 309.2 GARAGE FIRE SUPPRESSION SYSTEM WHEREAS, the City oftrussville adopted the International Residential Code to regulate residentia} construction under Ordinance 2003-046-EI effective January 1, 2004; and WHEREAS, this code requires separation of residential garages and residential living space, and where as sections 309.1.1 and 309.2 of this code prescribe that a fire resistant ceiling shall be installed; and WHEREAS, hanging ductwork and plumbing often make this installation difficult or impractical, Jefferson County and other municipalities have adopted a similar alternate method of compliance. NOW, THEREFORE, BE IT ORDAINED by the City Council ofthe City of TrussviHe, Alabama that the following alternate methods for compliance with the 2003 International Residential Code 309.1.1 and 309.2, Garage Fire Suppression System, shall be allowed: Approved Alternate Garage Fire Suppression System. Contact licensed fire sprinkler contractor for design & installation. Minimum 3/4" domestic water line for sprinkler demand with 1" domestic preferred. C D. IRC 309.1.1 & 309.2 apply to garage areas only. The use of the garage fire suppression alternate would require: 1. A sheetrock wall between the garage area and finished/unfinished basement areas. 2. For full unfinished basements with garage doors present, sprinklering of the entire basement is required, if vehicles can be parked throughout, it's all a garage area. Required alarm notification for garage fire suppression system: 1. Flow switch and tamper valves must be tied to an electric alarm bell to alert resident of a water flow situation or the supervised valve is turned off The alarm bell must be mounted in the living area of the house. 2. In the event a home security alarm is installed in the house, the flow and tamper switches may be tied into the alann system to audibly alert residents.

E. Fire Suppression System components: 1. Supply piping to fire suppression must be minimum I" schedule 40 black pipe with sprinkler heads spaced no greater than 14' apart on branch lines and no more than 7' from any wall ( maximum @ 144 sq. ft.) CPVC pipe may be used if floor system is constructed of solid wood joists. Engineered joists require steel pipe. 2. Sprinkler heads must be "quick response" (155 degrees), standard spray with 1/2" threaded and minimum of 3/8" orifice size. Upright heads are recommended with deflector no more tha114" below bottom of ceilingjoists. Pendant heads may be used in areas where horizontal obstructions dictate and located with deflectors just under obstruction. 3. Floor areas beneath "open" garage doors must be protected. Recommend use of residential side wall heads mounted no more than 2" below the bottom plane of the garage doors in the open position. 4. Fire protection system riser must be tied to the domestic water system "upstream" from the pressure reducing valve. All valves controlling water to the fire suppression system specifically must be supervised. (This does not include the valve pit at the street or any valves that cut off water to the entire house.) F. Inspection for compliance: Building contractor or sprinkler contract shall notify City of Trussville Fire Department at 655-9123 when the "entire" system is completed and ready to be tested. The Fire Marshal will check for proper system components> alarm location and head placement. Section II. Drop-in Fire Rated Ceiling Assembly. A. A UL approved drop-in ceiling assembly (grid, hangers, lights, etc.) rated for one hour fire resistance may be used as an alternate. B. Inspection for compliance: An inspection for compliance shall be done by the Building Inspections Department at the rough-in stage and after installation is completed. Section III. Repealer: All ordinances or parts of ordinances heretofore adopted by the City Council of the City of TrussvilleJ Alabama which are inconsistent with the provisions of this Ordinance are hereby expressly repealed. Section IV. Severability: If any pa11, section or subdivision of this ordinance shall be held unconstitutional or invalid for any reason, such holding shall not be construed to invalidate or impair the remainder of this ordinance, which shall continue in full force and effect notwithstanding such holding.

Section V. Effective Date: This ordinance shall become effective immediately upon adoption and publication as provided by law. ADOPTED AND APPROVED this the,d day of February, 20d..

.,...,,:...( Alternate Method for Compliance WithIRC309.1.1 &309.2 Garage Fire Suppression System I. II III. IV. Contact licensed fire sprinkler contractor for design & instaliation. Minimum 3/411 domestic water line for sprinkler demand with ]11 domestic preferred. IRC 309.1.1 & 309.2 apply to garage areas only. The use of the garage fire suppression alternate would require: A. A sheetrock wall between the garage area and finished/unfinished basement areas. B. For full unfinished basements with garage doors present. sprinklering of the entire basement is required, ifvehic1es can be parked throughout, it's all a garage area. Required alarm notification for garage fire suppression system: A. Flow switch and tamper valves must be tied to an electric alarm bell to alert resident of a water flow situation or the supervised valve is turned off. The alarm bell must be mounted in the living area of the house. B. In the event a home security alann is installed in the house, the flow and tamper switches may be tied into the alarm system to audibly alert residents. v. Fire Suppression System components: A. Supply piping to fire suppression must be minimum 1" schedule 40 black pipe with sprinkler heads spaced no greater than 14' apart on branch lines and no more than 7' from any wall ( maximum @ 144 sq. ft.) CPV C pipe may be used if floor system is constructed of solid wood joists. Engineered joists require steel pipe. B. Sprinkler heads mus be "quick response" (155 degrees), standard spray with 1/2" threaded and minimum of 3/8" orifice size. Upright heads are recommended with deflector no more than 4" below bottom of ceiling joists. Pendant heads may be used in areas where horizontal obstructions dictate and located with deflectors just under obstruction. C. Floor areas beneath "open" garage doors must be protected. Recommend use of residential side wall heads mounted no more than 2" below the bottom plane of the garage doors in the open position. D. Fire protection system riser must be tied to the domestic water system "upstream" from the pressure reducing valve. All valves controlling water to the fire suppression system specifically must be supervised. (This does not include the valve pit at the street or any valves that cut off water to the entire house.) VI. Inspection for compliance: Building contractor or sprinkler contract shall notify City of Trussville Fire Department at 655.9123 when the "entire" system is completed and ready to be tested. The Fire Marshal will check for proper system components, alarm location and head placement.

CERTIFICATION I, Lynn Porter, City Clerk of the City oftrussville, Alabama do hereby certify that the following is a true and COlTect copy of Ordinance Number 2004-011-EI of the City oftrussville, Alabama, adopted on February 10,2004 and posted in the following places: Trussville Municipal Building Trussville Public Library Trussville Community Center on February 11,2004, and effective five days thereafter. Given under my hand and seal this 16th day of February, 2004.