COMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX)

Similar documents
COMPACT FLAME CONTROLLER CFC 1000

COMPACT FLAME CONTROLLER CFC 2000

COMPACT FLAME CONTROLLER CFC 100

FLAME AMPLIFIER MODULE 3001

FLAME AMPLIFIER MODULE 3001D

Products Catalog. Flame Monitoring & Evaluation Systems

Products Catalog. Flame Monitoring & Evaluation Systems

Flame Monitors BROCHURE

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

ABB. Measure IT Uvisor System Dual sensor flame scanner. UR460 Mod. UVIR /ER/EF/DV Flame Scanner Product Data Sheet (rev B)

ABB. Measure IT Uvisor System Flame scanner for gas and oil burners. UR450 Mod UV flame scanner Product Data Sheet (Rev. B)

ABB. Measure IT Uvisor System Flame scanner for fuel oil and coal flame. UR600 IR Mod flame scanner Product Data Sheet (rev.

UV - flame detector dual fuel burners for intermittent burner operations

Manual Power relay SR853

Wide Band Flame Detector KLC 20 for all kind of oil flames with intermittent burnerr operations

UV Flame Supervision System

Product Overview Combustion Technology

Dräger Flame 2100 Flame Detection

Dräger Flame 2500 Flame Detection

System Overview F300K Compact Flame Scanner. Sensors and systems for combustion engineering.

D-GF 150. Burner Control for Gas and Oil Burners Flame Sensor D-GF 150 D-LE 103

Product Overview Combustion Technology

IRIS IP65 IRIS UNISCAN APPLICATION MANUAL

Dräger Flame 2500 (IR3) Flame Detection

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Dräger Flame 2700 (Multi-IR) Flame Detection

UV - flame detector KLC 10 for oil -, gas- and dual fuel burners for intermittent burner operations

Dräger Flame 2350 (UV&IR) Flame Detection

Acessories BROCHURE JUNHO 2013

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Dräger Flame 2370 (UV&IR) Flame Detection

MBCE-110/230UV Flame Sensor Module

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Dräger Flame 2100 (UV) Flame Detection

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Engineering Guideline. pac- Carriers Type Universal

Symphony Plus Combustion instruments

INSTRUCTION MANUAL (ATEX / IECEx)

VERSAFLOW VORTEX Supplementary instructions

FIREYE C9707A ALL FUEL SCANNER

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Certificate of Compliance

Dräger Polytron 5100 EC Detection of toxic gases and vapors

LFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02

INSTRUCTION & SERVICE MANUAL

Certificate of Compliance

Eclipse 90 UV Scanner Model A Version 1

UV Scanner. Model Specification. Introduction. 854 Instruction Manual

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

FlowJam S Ex. Bulk Flow Detection. Operating Instructions. SWR engineering Messtechnik GmbH

W-FLAME IR/UV FLAME DETECTOR

U2 Combination Viewing Head and Signal Processors

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

Dräger Polytron 5720 IR Toxic Gas Detection

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

Flameproof Manual Call Points

Integrated Solutions Low Voltage Systems

DSF-2010-SB KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE!

standards: standards:

Snifter ATEX22 VERSION. User Manual. Distributor

The SharpEye 40/40I (IR3) Flame Detection

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

HAUBER-Elektronik. Product overview. Condition monitoring Mechanical protection in compliance with DIN ISO 10816

DICTATOR Hold-Open Systems for Hazardous Areas

Dräger Polytron 8720 IR Detection of carbon dioxide

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Operating Manual MS220KA and MSR220KA

S55XB and S55XBE Series Viewing Heads

S55XB and S55XBE Series Viewing Heads

DSF-2010-SB KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE!

EZ-FLAME Detector USER MANUAL

D-LX 100 All-In-One Flame Scanner

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors.

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Drive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Continuous Gas Analyzers AO2000 Series AO2040-CU Ex Central Unit in Category 2G. Operator s Manual 42/24-13 EN Rev. 3

OMC Ex interface unit. Manual. Version 1.2 August Author: Observator Instruments

TYPE 95IR/95UV/95DS. Integrated Flame Scanner with Internal Flame Relay TUV SIL2 DESCRIPTION MODEL S1, S2. RoHS Compliant to EU Directive 2002/95/EC

Operating Manual Distribution box

Technical Description Relay Module Flame Detector

LFE50. UV Flame Safeguard. Building Technologies Division DETACTOGYR

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Flame Detection Jon Sarfas

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

Engineering Guideline. pac-carriers Type for TRICON system TRICONEX TMR PLC

VIESMANN. VITOMAX 200-LW Low pressure hot water boiler for permissible flow temperatures up to 120 C Rated heating output 8.0 to 20.0 MW.

Fibre Optic System D-LL 703/704

VIESMANN. Installation instructions VITOMAX 200-HW. for contractors

Dräger Polytron 8000 Stationary gas detector (EC)

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Power Supply Display Module PSDM. Installation and Operation Manual

Fireye Flame Safeguard Controls

Gas cooler series TC-Standard+ X2

The SharpEye 40/40M (Multi IR) Flame Detection

Transcription:

COMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX) TECHNICAL DESCRIPTION EDITION: TB CFC200-REV3-2015-04-07 IMPORTANT: Please note, that all mounting and wiring as well as all changing or adjustment at the flame monitoring and evaluation equipment should only be carried out by fully trained and authorized personnel. BFI Automation is pleased to support you if you do not have any experience with the equipment. Our service personnel is carrying out world wide installations, supervision and commissioning and is available upon request. For the stage of planning you can ask our sales and project engineers for any support you may need. BFI Automation is providing any kind of training for your engineers. PLEASE READ THIS LEAFLET CREFULLY AS IT CONTAINS NECESSARYIN- FORMATION FOR THE USE OF THIS EQUIPMENT. FOR MORE DETAILED IN- FORMATION PLEASE REFER TO THE OPERATING AND MAINTENANCE MA- NUAL. BFI Automation Mindermann GmbH, Eggerscheidter Str. 57, D-40883 Ratingen Phone +49 (0) 2102 96 82 0, Fax +49 (0) 2102 9682 42 EMail: info@bfi-automation.de 1

Compact flame controller CFC 200 - Flame scanner with integrated flame controller TÜV approved, DIN-DVGW certified CFC 200 UV1 (formerly 8.0) : recommended for pure gas and oil/gas mixture fuels CFC 200 UV (formerly 8.30) : recommended for pure gas and oil/gas mixture fuels CFC 200 IR (formerly 8.40) : recommended for pure oil fuels in diffusion burners CFC 200 IR3 (formerly 8.70): recommended for gas fuels in radiant-surface burners and for waste gases Adjustable sensitivity Analogue flame intensity output Optical state indication Non-wearing sensors Protection IP 65! WARNING WARNING: IMPROPER INSTALLATION OF THESE PRODUCTS MAY BE HAZARDOUS TO LIFE AND PROPERTY Function The integral method in the respective spectral range is used for the flame radiation analysis of the compact flame controller. After pre amplification, the unwanted portion of constant light is withdrawn from the output signal. The subsequent sensitivity adjustment permits signal suppression for the adaptation to the respective burner condition. The subsequently connected band pass filter achieves that modulation of the typical flame radiation of the primary combustion zone is evaluated only, and outside light signals from neighbouring burners can be differentiated from the individual burner. The further functional groups integrate the signal processing for the dynamic monitoring channel, which, by means of a dark-phase monitoring, continuously checks the failure-safety of the unit. A component defect leads to an immediate switch-off of the flame-relay, which is available as a potential-free changeover contact. The switching state flame on is displayed by a yellow LED on the rear side of the unit, just as the intensity of flame, which is displayed by a flashing green LED. A flame intensity output 0(4) - 20 ma can be used for external displays. The range can be selected by jumper see drawing on page 3. The safety switch-off time, which always depends on the fuels to be detected, is factory adjusted to 1 second. Longer switch-off times in acc. to local specifications available as option.! WARNING WARNING: The response of the scanner depends on burner configuration as well as on the turbulence and spectral characteristics of the flames. Application assistance is available on request 2

Sensitivity Adjustment By using a potentiometer which is located on the back side of the compact flame controller beneath a screw it is easily possible to adapt the controller to various firing conditions. Turning the potentiometer counter clockwise will reduce the sensitivity. Please note that a reduction of the sensitivity might also cause a reduction of the current output for the intensity. Output current selection 0-20 ma 4-20mA Jumper Assembly The correct positioning of the sight tube to the flame with less vibration is an important requirement for an optimised flame control. The assembly must ensure the primary combustion zone is inside the visible angle of the flame monitoring device for all loads. This is the only way for discriminating flame control. The extension of the sight axis may not cross the first third of other flames. Length and diameter of the sight tube are directly related to the available flame radiation, because the visibility angle of the device is defined. The maximum length L of a sight tube is related to the tube s diameter d. d 1" 1,5" 2" L 0,5m 0,8m 1,1m The tube should be as short as possible. A diameter of 2 inch is recommended. The right adjustment is shown in the following drawing. The optical adjustment device BFI 235 is available ex stock (part-no.: P 106) The compact flame controller is delivered with a flange for quick assembly. The device is equipped with a supply for purge air which prevents the lens of contamination with dust and a subsequent damage. The optimised assembly kit consists of heating insulator, blocking valve and ball flange. These mechanical devices are also available on demand. 3

flame root combustion area primary air fuel changing of frequency and amplitude in relationship to the distance of the flame root flame scanner mounting flange ball flange sight tube how to adjust in the right way 30 adjustment angle 30 max optical adjustment heating insulator right wrong 30! CAUTION CAUTION: All alignment and adjustment procedures should be used whenever parts are replaced, when the scanner has been moved, when the flame shape has altered (additional fuels, new burners, burner/register modifications), as well as on new installations. 4

Installation The pin configuration of the plug connector is shown in the terminal connection diagram. The flame intensity output has no potential separation from the power supply. It is related to the power supply ground. If there will be any problem in this case an isolation amplifier can be delivered on demand. A maximum shunt resistance of 250Ω should not be exceeded. The device is immediately ready for operation after switching on the power supply.!!do not disconnect the flame controller while energized!! Connection diagram Pin/Terminal Description Colour of BFI special cable KW5 1 Flame relay: supply root white 2 Flame relay: signal flame ON brown 3 Flame relay: signal flame OFF pink 4 Power supply: +24 V DC green 5 Power supply: - 0 V (GND) yellow 6 Current output: 0(4)-20 ma grey BFI-special cable KW5 power supply +24V DC green 4 4 flame relay "flame ON" brown 2 2 flame relay "root" white 1 1 flame relay "flame OFF" pink 3 3 power supply 0V (GND) yellow 5 5 current output 0/4-20mA grey 6 6 compactflamecontroller outer braided shield! CAUTION CAUTION: On all applications the compact flame controller must be tested by starting and stopping the burner several times to ensure proper operation. (e.g.: The flame relay must reliable drop out for all flame conditions.) The testing should be done with various adjacent burners ON and OFF and at various load levels. This is a requirement for proper operation. 5

CFC 2000 Standard housing Standard housing suitable for use in hazardous area Zone 2 II 3 G Ex na II T4 OE-Converter housing SKL G1 155 152 120 BFI 88 122 106 Fibre optic cable O/E-Converter Suitable for use in hazardous areas Zone 2 II 3 G Ex na II T4 6

Ex-proofed housing 2 8 6 G 1 Ø120 Empfindlichkeitseinstellung LED grün = Intensität LED gelb = Flamme "EIN" For areas classified as Zone I PTB 03 ATEX 1051 0044 Type 07-6152-9016 II 2G Ex de IIC T6 II 2D Ex td A22 IP 65 T 80 C Explosion Proof Housing for OE-Converter For one OE-Converter Ø13 232 262 304 14 142 166.5 232 195.5 0044 Type 07-4160-1165/5003 II 2G Ex de IIC T6 Gb II 2D Ex tb IIIC T 80 Db For use in hazardous areas classified as Zone 1 KEMA 08 ATEX 0123 7

Accessories Power supply 230/115V AC Swivel mount 1 inch and 2 inch flange disk Heating insulator 1 inch 3-way ball cock 1 inch Pressure screw joint 5bar size 1 inch Optical adjusting device Technical data Spectral sensitivity CFC 200 UV1 (formerly 8.0) CFC 200 UV (formerly 8.30) CFC 200 IR (formerly 8.40) CFC 200 IR3 (formerly 8.70) Visual aperture Input voltage Current consumption Construction Ambient temperature Current output Flame relay Flame failure response time, switch-off time 190 up to 550 nm 280 up to 420 nm 300 up to 1050 nm 1050 up to 2700 nm 2.7 degrees 24 V DC approx. 200 ma according to SELV III -20 C...+70 C 0(4)...20 ma (Ra < 250 Ohm) flame intensity 1 change-over contact, potential free VDE 0110, Class A max. 48 V switching voltage max. 1 A switching current (fused with 0.5 A) max. 30 W switching power switching point "flame on"5(8) ma switching point "flame off"< 5(8) ma 1 second, factory preset other switch off times on request Sight tube connection 1" internal thread ISO 228 Purge air connection 1/2" internal thread ISO 228 Purge air quantity 10 m 3 /h at standard conditions Electrical connection Standard Flame proof housing OE-Converter EX-OE-Converter Dimension Standard with flange Explosion proof housing OE-Converter housing Ex-OE-Converter housing Triple Ex-OE-Converter Harting connector HAN8 90 degrees 3m special cable Harting connector HAN8 90 degrees M20-screw joint and terminal clamps inside 235 x 108 mm (Length x Diameter) 223 x 120 mm (Length x Diameter)* 120 x 122 x 80mm (Length x Width x Height)* 232 x 232 x 166,5mm (Length x Width x Height)* 276 x 276 x 218mm (Length x Width x Height)* *without plugs and mounting bracket 8

Class of protection Standard and OE-Converter housing IP 65, similar to NEMA 4/Class 1 Div 2 ATEX Zone 2 II 3 G Ex na II T4 Ex proof housing IP66, similar to NEMA 4/Class 1 Div 1 ATEX Zone 1 PTB 03 ATEX 1051 0044 Type 07-6152-9016 II 2G Ex de IIC T6 II 2D Ex td A22 IP 65 T 80 C Weight Standard Explosion proof housing OE-Converter housing Ex-OE-Converter housing Triple Ex-OE-Converter h. Ex-OE-Converter housing ATEX Zone 1 KEMA 08 ATEX 0123 0044 Type 07-4160-1165/5003 II 2G Ex de IIC T6 Gb II 2D Ex tb IIIC T 80 Db 1.5 kg 4.0 kg 1.5 kg 7.0 kg 13.0 kg Electronic self-monitoring for the fail-safe function control of the device according VDE 0116, EN 298:2012, and TRD 411 to 414. DIN-DVGW approved and CE conformity. Certified to CSA standards. Rights for technical changes reserved BFI AUTOMATION 2015 9