USER MANUAL SPRAY GUN CLEANER - WATER BASED PAINTS UA400W CAUTION FOR WATER BORNE PAINTS ONLY

Similar documents
OPERATING MANUAL UG2000D SERIES SPRAY GUN CLEANERS UG2000D, UG2000DM UNI-RAM CORPORATION ONTARIO CANADA UG2000DM UG2000D REVISION

UPP7500E2 AUTOMATIC PRESSURE POT CLEANER

OPERATING MANUAL SOLVENT SPRAY GUN CLEANERS UG5000E, UG5000DVM AND UG5500E UNI-RAM CORPORATION ONTARIO CANADA PATENTS

OPERATING MANUAL SPRAY GUN CLEANERS UG UG3000 SERIES UNI-RAM CORPORATION ONTARIO CANADA PATENTS

OPERATING MANUAL MANUAL WATER BASE GUN CLEANERS UM120W UNI-RAM CORPORATION ONTARIO CANADA PATENTS

CAUTION UM120W (RIGHT TANK) FOR WATER BORNE PAINTS ONLY UM120W (RIGHT TANK) SECTION IS NOT DESIGNED FOR USE WITH SOLVENT BASED PAINT

UM120W OPERATING MANUAL MANUAL WATERBORNE GUN CLEANER CAUTION FOR WATERBORNE PAINTS ONLY UNI-RAM CORPORATION ONTARIO CANADA

OPERATING MANUAL SPRAY GUN & PRESSURE POT CLEANERS UG4000 & UG6000 SERIES, UPP6500E UNI-RAM CORPORATION ONTARIO CANADA PATENTS

OPERATING MANUAL AUTOMATIC SPRAY GUN CLEANERS UG7500 SERIES UNI-RAM CORPORATION ONTARIO CANADA PATENTS

OPERATING MANUAL UG5000W SERIES SOLVENT AND WATERBORNE SPRAY GUN CLEANERS MODELS UG5000W UG5500W UG5000EW UG5500EW CAUTION RIGHT TANK (UM120W)

2001 Smith Eastern Corporation

USER MANUAL UR500VAC UR480VAC UR500VAC-E UR480VAC-E UR500VAC-A UR500VAC-J AUTOMATIC DUST VACUUMS MODELS UNI-RAM CORPORATION ONTARIO CANADA

USER MANUAL UR700QVAC and UR700QVAC-H

COMBO605 UNI-RAM CORPORATION ONTARIO CANADA

USER MANUAL. COMBO605/606 and COMBO655/656 UNI-RAM CORPORATION ONTARIO CANADA COMBO605. Revision

Cascade Automatic Spray Gun Cleaners clean the interior and exterior of spray-guns and pots in under 60 seconds

USER MANUAL BB30N & RI 20 UNI-RAM CORPORATION ONTARIO CANADA

Economy Models. Cleans 1 Spray Gun and Pot using Wash Timer 9 Swirl Action Jets Tank Size 12.5 x 12 x 13.5 (WDH )

User Manual AIR HOG. Vacuum Booster REV. 3/20/ Stowe Dr. Poway, CA P: (858) F: (858)

Page 1 of 18. Part# /5/2013

OWNER S MANUAL. Models: Herkules Equipment Corporation 2760 Ridgeway Court Walled Lake, MI USA Fax

Engine Cooling Pulsator

USER MANUAL URS500 AND URS600 SERIES

Models: GW/R-T GW/R-2-T GW/R-3-T

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE

HOT WASHER MODEL NO: KING150

Operating Instructions for the BBO-1 and BBO-2 Basket Blasters

USER MANUAL URS2000 SERIES & RI 80 UNI-RAM CORPORATION ONTARIO CANADA

LITTLE BLASTER SET-UP INSTRUCTIONS FOR SHOT PEEN MACHINES WITH CARTRIDGE TYPE DUST COLLECTORS *** READ BEFORE OPERATING EQUIPMENT***

C-Box 100, H-Box 200 & H-Box 500

Sanitaire. Owner s Guide. 10 GALLON Box Extractor SC6088 Series IMPORTANT

WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS

INSTRUCTION MANUAL. Spray Gun Cleaner. Patent Pending. Warranty Service Parts Safety Troubleshooting Guide Operation Accessory Information

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE

PRO 2000i LOW LEVEL DEPOSITOR

Safety, Operation and Maintenance Manual with Parts List

Xaact Spot. Xaact Hot Spot

Setup. Important. Texture Spraying (material supplied from unit)

K Specifications. Max. Water Volume

K Specifications. Max. Water Volume

SAFETY PRECAUTIONS. 2) Before operating machine: - Make sure all safety devices are in place and operate properly.

USER MANUAL URS500 AND URS600 SERIES

High-Pressure Washer BY02-VBP-WTR BY02-VBP-WTH. CAUTION : Do not use this device before reading the instructions.

OPERATOR'S MANUAL. IMPORTANT: READ OPERATOR'S MANUAL CAREFULLY Please fill out & return your warranty card! DP80405

INSTRUCTIONS FOR SAFE USE INSTRUCTIONS FOR SAFE USE

Fig. 2. Fig. 1. Fig. 3. Fig. 4. Fig. 5. Fig. 7 Fig. 6. Fig. 9. Fig. 8. Fig. 10 MAX H2O

INSTRUCTION MANUAL 4HP WET / DRY VACUUM VC V 60 Hz 7A. Gal

RCM-77. Instruction Manual. G-Series Cooler. U.S. Patent No. 8,215,125 RECHARGE COLD MERCHANDISER

As part of the V.I.P. family, you are entitled to the best protection by one of the most comprehensive warranties in the industry.

UG5000W & UG5000WS. BOM Table of UG5000W UNI-RAM CORPORATION REV. FEB-2017 ITEM NO. PartNo DESCRIPTION QTY CABINET 1

SUPERIOR PERFORMANCE

OWNER'S SERVICE MANUAL NO INSPECTION, MAINTENANCE AND RECHARGE

Model HD 3501 Part No High Pressure Washer Operator Manual

Operator s Manual. Wet/Dry Vacuum with Detachable Blower 12 Gallon Model No. VBV1210 FOR YOUR SAFETY

Operator s Manual. 6 Gallon Model No. VQ607SFD FOR YOUR SAFETY. Read and understand this manual before use Keep this manual for future reference

8070 Mytee Lite. Instructions for. Please read before use. Register your product at support/register.

MACHINE SHOP ACCESSORIES CLEVER, TIME-SAVING PRODUCTS TO MAKE YOUR LIFE EASIER

LITTLE BLASTER LARRY HESS AND ASSOCIATES, INC. BLAST-IT-ALL P.O. BOX 1615 SALISBURY, NC WITH DUST COLLECTOR

INSTALLATION GUIDE S50M Solvent Spray Gun Cleaner

Owner s Manual Refrigerated Compressed Air Dryers Model F-100

Upholstery and Drapery Cleaner. Operator and Parts Manual. Model No.: gal Extractor. MNL32506 Rev. 00 (08-98)

Cavitator Ultrasonic Cleaner Instruction Manual

Flood Pumper Plus. Water Transfer Machine. Operator and Parts Manual. Model No.: Rev. 00 (11-99)

MC MC MC MC MC833130

POWER WASHER MODEL NO: JET 9000 OPERATION & MAINTENANCE INSTRUCTIONS. WARNING: Do not use the machine without reading this manual PART NO:

Parts and Instruction Manual EX12 Carpet Extractor

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

INDUSTRIAL VACUUM CLEANER WITH AUTO START/STOP

Model K 3000 G Part No

4000IS PROFESSIONAL IRONING SYSTEM INSTRUCTION MANUAL

Operator s Manual. 2.5 Gallon Model No. VOM205P FOR YOUR SAFETY. Read and understand this manual before use. Keep this manual for future reference.

Owner s Manual Refrigerated Compressed Air Dryer Model F-50

Model K 330 M Part No

Tornado Operation & Maintenance Manual

Instruction Manual. Pressure Washer. Get ready to deep clean! Wards.com Wards.com ITEM:

PNEUMATIC VACUUMS ATEX Certified For Hazardous Locations OPERATING MANUAL

ORIGINAL INSTRUCTIONS

SYSTEMS for CATALYTIC FILTERS

Cavitator Ultrasonic Cleaner Instruction Manual Model 20G

High Pressure Washer Operator Manual. Specifications Model HD 2700 DH/DB

SERVICE MANUAL (v1) UL / ULC. WET CHEMICAL HAND PORTABLE RESTAURANT KITCHEN FIRE EXTINGUISHERS Model: SF-6LK / WBDL-6LK

30 Misting/Oscillating Fan Model Number 01030

Manual for MC91 SETUP INSTRUCTIONS

Specifications. Vacuum motor power consumption(w/hp) 1200 / 1.6. Exhaust water pump power consumption(w/hp 800 / 1.1

Model K 280 M Part No

Electric Pressure Washer NOTE: REFER TO PRODUCT MANUAL FOR ALL SAFETY INSTRUCTIONS

55-Gallon Dispenser Package

Model K 5800 G Part No

Explorer CleaningPartsDirect.com Carpet Extractor. Operator and Parts Manual. Home Find... Go To.. Model No.: Can.

OPERATOR'S MANUAL HD-400

Manual for MC37/MFC3600

CONGRATULATIONS! TABLE OF CONTENTS

Cavitator Ultrasonic Cleaners

Model K 520 M Part No

THE BLACK PROVAC BACK PACK VACUUM CLEANER

SERVICE/INSTALLATION MANUAL ICE ONLY DISPENSERS MODELS-IOD150, IOD200 AND IOD250

K 2.97 M. Specifications Operating pressure, max PSI Water volume GPM Voltage V Amp draw AMPS

solvent and waterborne spray gun washers


Transcription:

USER MANUAL SPRAY GUN CLEANER - WATER BASED PAINTS UA400W CAUTION FOR WATER BORNE PAINTS ONLY THIS UNIT IS NOT DESIGNED FOR USE WITH SOLVENT BASED PAINT UNI-RAM CORPORATION ONTARIO CANADA REV 2010-09

CONTENTS INTRODUCTION.............................................................. 3 SET UP DELIVERY INSPECTION................................................. 3 LEVELING AND AIR SUPPLY............................................. 3 PAIL SETUP........................................................... 4 INSTALL AIR BLOW GUN............................................... 4 OPERATION PRE-CLEAN........................................................... 4 CLEANING SPRAY GUNS AND CUPS.....................................4-5 AFTER CLEANING...................................................... 5 MAINTENANCE.............................................................. 6 REPLACING WASH WATER..................................................... 6 TROUBLESHOOTING CHART................................................... 6 TROUBLESHOOTING PROCEDURES............................................. 7 FLOW DIAGRAM............................................................. 8 REPLACEMENT PARTS........................................................ 9 FULL PRODUCT WARRANTY................................................... 10 2

INTRODUCTION Uni-ram Corporation holds many patents on designs used in its innovative products. Every machine is tested for compliance with Quality Assurance standards. Follow the directions in this manual under Setup, Operation and Maintenance in order to operate this machine safely and effectively. Not following these instruction can lead to malfunction or damage to the machine. Ensure that the manual is readily available for the operator at all times. If you have any questions about the operation of this machine, call your distributor. SETUP CAUTION FOR WATER BORNE PAINTS ONLY THIS UNIT IS NOT DESIGNED FOR USE WITH SOLVENT BASED PAINT DELIVERY INSPECTION Inspect the shipping carton for any sign of transport damage. Carefully remove the unit from the shipping carton and check the unit for damage. Report any transport damage immediately to the carrier and your vendor. Initiate a freight claim with the carrier. The manufacturer is not responsible for the freight damage. Check for the parts listed below. If any are missing, contact your supplier. Qty Included Parts 1 MANUAL 1 NOZZLE EXTENSION (INSTALLED) 1 PUSH-ON NOZZLE EXTENSION, LARGER TIP (ACCESSORY KIT) 1 PUSH-ON NOZZLE EXTENSION, SMALLER TIP (ACCESSORY KIT) 1 AIR BLOW GUN 2 SPRAY JETS 2 TRIGGER CLAMP & PLUG KIT 2 AQUA-KLEEN PGC CLEANER 2 PAILS 780-3530 SELECTION OF NOZZLE EXTENSION INSTALLED. HOLES PROVIDE SOLVENT TO CEAN DISPOSABLE CUP ADAPTOR. CANNOT BE USED FOR CONVENTIONAL SYSTEMS. 110-430PPS HOLES PROVIDE SOLVENT TO CLEAN DISPOSABLE CUP ADAPTOR. MAY ALSO BE USED FOR CONVENTIONAL SYSTEMS WITH LARGER OPENINGS IN NECK OF CUP. 110-430 FOR CONVENTIONAL SYSTEMS ONLY WITH SMALLER OPENINGS IN NECK OF CUP. LEVELING AND AIR SUPPPLY Level the machine using the adjustable legs. If required, attach a Moisture Filter (not supplied) to the Air Inlet, then attach an air supply adapter (not supplied) to the Moisture Filter. The air supply pressure must be at least 85 PSI and the air must be free from contaminants such as water, dust, rust, tar, grease etc. To prevent damage to the Diaphragm Pump an internal Air Pressure Regulator has been installed to limit the air pressure to precisely 85 PSI. Do not install a second air pressure regulator or use a pressure set below 85 PSI. 3

PAIL SETUP Open the door to the base cabinet Move the Drain Valve handle to the "closed" (horizontal) position if it is not already there. Two 5-Gal (19 L) pails of water are required, one full and one containing 3 gal. Place the pails in front of the machine - full pail on the right ((CLEAN RINSE) and the partially filled pail on the left (WASH). Add a full bottle of Aqua-Kleen (946 ml) to the full pail on the right and a partial bottle (three-fifths) to the partially filled (WASH) pail on the left. Inside the cabinet you will see two pipes strapped together, the Suction Pipe (with a black section at the top) and the Rinse Pump (all silver). Cut the strap holding them together. Do not cut the other straps holding the black and blue tubes. Disconnect the Suction Pipe from the Drain Valve by pushing the gray button and bring both pipes outside of the cabinet. Insert the Rinse Pump into the full pail on the right and the Suction Pipe into the pail with 3 gal on the left. Re-connect the Suction Pipe to the Drain Valve. If the Flow-through Brush is being used for manual pre-cleaning, the supply tube for the Brush should be inserted through the lid of the left (WASH) pail. If the Flow-through Brush is being used for manual cleaning after the Auto cycle, check to make sure the tube for manual clean rinse is inserted into the lid of the right (CLEAN RINSE) pail. Move the pails into the cabinet and re-connect the Suction Pipe of the left pail to the Drain Valve. INSTALL AIR BLOW GUN (Shipped with the Accessory Kit) Insert the blue tube into the outlet on the side of the tank and store the Gun in the bracket. OPERATION PRE-CLEAN Disconnect the spray gun from the air hose. Pour paint from the cup (when present) into a 5 gallon pail (not supplied). Rinse cup with water and pour into the same 5 gallon pail for later disposal or recycling. CLEANING SPRAY GUNS AND CUPS NOTE: During automatic cleaning, air is mixed into the cleaning water/solution to improve the cleaning process. Loosen the air cap of the spray gun two full turns. Lock the trigger in the open position with the Trigger Clamp. To prevent liquid from entering the air passgae during automatic cleaning, insert the white plastic Air Passage Plug into the Spray Gun's air inlet. If the air inlet has a male threaded connector instead of a quick connect use the knurled nut attached to the Trigger Clamp (included). Place spray guns facing corner jets. Placement depends on type of spray gun. (See pictures on next page.) Place cups onto the low spray jets and cup holders. Note on Gravity Feed Spray Gun: Some customers prefer to clean the cup separate from the spray gun. Close the lid and turn the Auto Wash Timer knob clockwise to start cleaning. Start with 5 minutes (maximun setting marked "5") and reduce the cleaning time on subsequent runs if desired. Push and hold the "Air Rinse" button for about 3 second to air-rinse the guns. Push and hold the "Clean Rinse" button for about 5 seconds to rinse guns with clean water. This will send a pre-set amount of clean water (100 cc) through the jets. Wait 30 seconds for the Rinse Pump to fully recharge before repeating. The water fl ow per clean-rinse cycle is limited to 100 cc to minimize consumption. This quantity is usually sufficient to clean the inside passages of the spray guns. 4

Manual Wash The Flow-through Brush is used to manually clean guns. Make sure the Brush supply tube has been insered into the correct pail (see the section: PAIL SETUP). To clean with the Brush, open the lid and step on the Foot Pedal. Manual Dry The Air Blow Gun is used to manually dry the guns. First remove the Trigger Clamp and Plug. In turn, separately dry the paint channel, the air channel and the exterior of the gun. CAUTION: MAKE SURE THE GUNS ARE COMPLETELY DRY AFTER USE. AFTER CLEANING Do not store spray guns in the tank. 5

MAINTENANCE Inspect the screen at the bottom of the tank and clean when necessary. REPLACING WASH WATER Disconnect the Suction Pipe from the Drain Valve and remove the pipe from the pail. Move the pail out of the cabinet dispose of the wash water. Remove the Rinse Pump from the other pail, move the pail out of the cabinet and locate on left side for use with the suction pipe. Replace as described in the Pail Setup section. TROUBLESHOOTING SYMPTOM REASON CORRECTIVE ACTION WASH LIQUID DOES NOT FLOW AND PUMP MAKES A PUMPING NOISE WASH LIQUID DOES NOT FLOW AND PUMP MAKES A HISSING NOISE WASH LIQUID DOES NOT FLOW AND PUMP DOES NOT MAKE A NOISE PUMP DOES NOT STOP UNLESS TIMER IS TURNED BY HAND OR AIR IS SHUT OFF INSIDE WALL OF TANK IS COATED WITH PAINT EVEN THOUGH OPERA- TOR MAINTAINS TANK GUNS NOT CLEAN, PUMP WORKING Drain valve closed Liquid level too low Paint debris in pump Water in air line causes pump to stall Pump leaks Blockage in air passage Defective Timer Cleaner lacks cleaning strength Trigger not locked in open position Open drain valve (put in verticle position), if not already open Check wash liquid level. Add liquid if less than 1/2 full. Check wash liquid level. Add liquid if less than 1/2 full. Follow Procedure 1, "Blocked Fluid Passage in Diaphragm Pump" Follow Procedure 2, "Blockage in Air Passage in Diaphragm Pump" Replace pump Follow Procedure 3, "Blocked Passage in Air Line". Follow Procedure 1, "Blocked Fluid Passage in Diaphragm Pump" Replace liquid cleaner. Use Trigger Clip Cleaning solution is dirty Filter is clogged. Replace Replace 6

TROUBLESHOOTING PROCEDURES PROCEDURE 1 Blocked Fluid Passage In Diaphagm Pump If the pump sounds like it is working but liquid does not flow, clear the fluid passage as follows: Remove suction tube from the pail and blow air at 85 PSI into the INLET Sovent Hose (see diagram). Step on foot pedal. This procedure may have to be repeated several times. If this procedure does not help, blow some water into the suction hose using a spray gun, wait one minute and step on foot pedal. This procedure may have to be repeated several times. If this procedure does not work, the pump must be replaced. If you need to replace the pump call your local dealer. The warranty on the diaphragm pump is two years from date of purchase. INLET This procedure will also clear a blockage in the fluid line for the wash gun. PROCEDURE 2 Blocked Air Passage In Diaphragm Pump If there is a steady hissing sound and the pump is not cycling, the spool valve has stalled due to a blocked air passage. Follow the procedure below to clear the blockage. Connect a blow gun to an 85 PSI source. Locate the blue hose that extends from the air exhaust port of the diaphragm pump. Use a blow gun to blow air into the open end of this hose. Turn timer. If the procedure is successful, the pump will start working. The procedure may have to be repeated several times. If this procedure does not work, replace the pump. Cause: Contaminants in the air supply (water, oil, solid particles etc) Preventative Action: If necessary, install an Airline (Moisture) Filter. PROCEDURE 3 Blocked Passage in Air Line The components in the air line are the diaphragm pump, air valve, foot pedal, 3-way ball valve and regulator. See the Flow Diagram and the section: Replacement Parts. To troubleshoot a component: 1) Disconnect the air line to the component using the quick disconnect. 2) Step on foot pedal and check for presence of positive air pressure in the air line. If there is ample positive air pressure, replace the component. If air pressure is absent, there is a faulty component upstream. Reconnect the air line and check the operation of the next component upstream by following steps 1 and 2 above. 7

FLOW DIAGRAM(S) Use the diagram(s) to trace the flow of compressed air and liquid. 8

REPLACEMENT PARTS DESCRIPTION Part Number FLOW-THROUGH BRUSH 144-390 DIAPHRAGM PUMPUDP4TA UDP4TA AIR BLOW GUN 102-7010 TIMER KIT 115-200/K PEDAL VALVE 115-400BF PEDAL VALVE, COMPLETE ASSEMBLY 780-4300 NOZZLE EXTENSION, REGULAR, PUSH-ON 110-430 NOZZLE EXTENSION, PPS, PUSH-ON 110-430PPS NOZZLE EXTENSION, PPS, THREADED 780-3530 TRIGGER CLAMP & PLUG KIT 140-2340 AIR PASSAGE PLUG 140-230 9

Full Product Warranty These products have been engineered and manufactured to high performance standards. Each unit has been subjected to detailed factory testing before shipment. This product comes with a one-year full warranty from the date of purchase. The manufacturer reserves the right to repair or replace the unit, free of charge, to the original purchaser if a part is found to be defective in material or workmanship as determined by factory service personnel. The items listed below under "Conditions of Warranty" as consumables are not covered. The manufacturer reserves the right to direct the customer to ship the unit collect to the factory or to an approved Service Center for repair or to repair the unit on-site. To prevent damage in transport, the purchaser must ship the unit in the original packaging or use alternate adequate packaging. All units must be shipped clean and free of liquid. Diaphragm Pump: We are pleased to advise that the warranty on the diaphragm pump, the heart of the spray gun cleaner, comes with a 2 year replacement warranty. If, in the unlikely event your diaphragm pump fails during the first two years of service, call for service. The manufacturer will send you a new pump free of charge and arrange for the return of your original pump. Conditions of Warranty: As the manufacturer has no control over the working conditions or circumstances under which the purchaser stores, handles or uses the product, the manufacturer makes no warranty or claim, either expressed or implied with respect to this product's fitness for any purpose or the result to be obtained from its use. This condition applies to the sale of all products and no representative or distributor has the authority to waive or change these conditions. This warranty applies only to the original purchaser and does not apply if the unit has been misused, overloaded, neglected, altered or used for any purpose other than those specified in the operating and installation instructions. Deterioration due to normal wear is not covered by this warranty. Damage due to accident, transportation, fire, floods or acts of God is also not covered. Units whose serial numbers have been altered or removed are not covered. The warranty is invalid if unauthorized chemicals as noted in the manual or liquids with acid content are used in this unit. Unauthorized attempts at selfrepair or alterations by the owner also invalidate this warranty. Interior or exterior finishes are not covered by this warranty. Consumable Items are not covered by this warranty (eg: gaskets, screens, bags, filters, nozzles and air jets). This warranty replaces all other warranties expressed or implied by statute or otherwise. To make a claim, call for service and quote the serial number of the unit. 10