OXeN. Ductless ventilation with heat recovery.

Similar documents
DUCTLESS VENTILATION WITH HEAT RECOVERY. OXeN ductless ventilation unit

OXeN. Ductless ventilation with heat recovery.

AIR HEATING AND VENTILATION. Fan heaters LEO

Gas heaters and convectors ROBUR

Adsolair 56/58. Comfort air conditioning unit with double plate heat exchanger and adiabatic evaporative cooling system

Catalogue 2015 AHU N Range: VENTUS VS 10 - VS 650

No. 1 in Europe New on offer air curtain GUARD

No. 1 in Europe New on offer air curtain GUARD

Resolair 62 and 66. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 1,200 4,300 m³/h

Adconair 76. Comfort air conditioning unit with counterflow plate heat exchanger. AIR VOLUME FLOW: 2,600 23,600 m³/h

TERM-E ELECTRIC HEATING AND VENTILATION UNITS

CHILLED BEAM CASSETTE IQ STAR LYRA

Units for suspended ceilings

SAVE gives great indoor climate and saves energy

Horizontal rotor heat recovery ventilation unit RH 5. Vertical rotor heat recovery ventilation unit RV 9

CONDOR. Supply air ceiling QUICK FACTS

DX SYSTEM HEAT RECOVERY ENHANCED BY DEMAND CONTROLLED VENTILATION

Technical documentation DTR AIR WATER HEATERS IN EPP CASING HC-3S SERIES

RIS V EKO A1/L2 RIS 700 V E L EKO 3.0 AIR HANDLING UNITS. Application

INTRODUCTION. JAU /JCC/JVC Series Jet Fans - for car park ventilation

EASYAIR COMPACT DEVICE THE EASY WAY OF AIR HANDLING.

AIR HANDLING UNITS. AmberAir Compact Smarty RIS EKO 3.0 RIRS EKO 3.0

F series close control air conditioners exploit the indirect FREE COOLING system with adiabatic cooling to ensure high system energy savings.

Technical documentation DTR

HEATING AND COOLING DEVICE AGC

iq Star LYRA II chilled beam cassette

Series VENTS VUT R WH ЕС

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction

LOWERING THE COST OF HIGH CEILINGS

HRV-IP. Ceiling Type Heat Pump Heat Recovery Unit

Heat Recovery Unit HERU. web-version

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

Units for suspended cei lings

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

EC A1/L2 RIS P EKO RIS 400 P E 0.9 EKO 3.0 AIR HANDLING UNITS. Application

COMMERCIAL LINE. DUPLEX MultiEco

Energy-efficient heat source provides comfort in large rooms

CAW Ceiling-mounted fan heaters for hot water

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses

Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK

for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

COMPACT VENTILATION UNITS DUPLEX R5

ECO ROOF FAN. A modern, energy-saving roof fan with a DC motor. INSTALLER Register the roof fan for an extended 5 year guarantee!

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

CONTENT: VEX308 Decentralised ventilation VEX308

Primo Hotel. General. Indoor climate units for hotel rooms

COMMERCIAL LINE DUPLEX ROTO

HRV Enthalpy. Catalogue

Ceiling air diffuser INDULTHERM INDULTHERM-e

Dehumidification and ventilation for residential, industrial radiant systems and swimming pools

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

Building Management System and T-Box integration

GAS AIR HEATER RANGE

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

AHU Plus. DX Air Handling Units

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS ENERGY-BOX HE

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

AIR HANDLING UNITS RIS P EKO 3.0. New range - 5 sizes, 20 models! Efficient EC. E f f i c i e n c y up to 94%! E x t r e m e l y low height! fans!

DAIKIN Air Handling Unit Modular

System architecture. Air treatment Index

1.1 VTS: number 1 in the world pillars of success

iq Star LYRA II chilled beam cassette

GLOBAL LP. Ceiling-mounted ventilation unit with plate heat exchanger

Bypass Terminal Units. DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.) BYPASS TERMINAL UNITS

AIR HANDLING UNITS ver B

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

INDUSTRIAL AIR CURTAIN. IndAC 2

Ceiling diffusers. Type DLQL

DX AIR CURTAIN. SensAir

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

PRODUCT DATA COMFORT 300 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 325 m 3 /h

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h

Homepage > Products > Grilles and Diffusers > Ceiling diffusers > Design ceiling swirl diffusers > Type ADD. Type ADD

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

Dee Fly Cube 300 and 370. Heat Recovery ventilation

air handling units AT THE LEADING EDGE OF AIR FLOW

Air curtain.

DEHUMIDIFIERS & VENTILATORS

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

EC A1/L2 RIRS V EKO AIR HANDLING UNITS

Comfort Ceiling Fan Coil System INDULVENT ec. Draught-free ambient air distribution with cooling capacity up to 2600 W

TECHNICAL DOCUMENTATION OPERATION MANUAL DTR ELIS A/1.0/ /PL

Compressors Manufacturing Company Ltd.

Ceiling swirl diffusers

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSWALL. Wall mounted fan coil units

INDUSTRIAL DEHUMIDIFIERS. Advanced range of compressor and desiccant dehumidifiers. Dehumidification and drying

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

SINGLE-ROOM HEAT AND ENERGY RECOVERY UNITS

The integral solution for. Air Handling Units. Technology & Evolution

Ceiling swirl diffusers

KOMFORT EC DB Suspended heat recovery air handling units

Fan coil unit KL. Wall unit Ceiling unit

VMA-VMB NOVA AIR HEATERS. NoVa air heaters

CLEVER CONTROL - Version: V6.0

Type TDF-SilentAIR WITH VERY LOW SOUND POWER LEVEL FOR COMFORT ZONES, WITH FIXED AIR CONTROL BLADES

ACCORDING ErP 2018 HEAT RECOVERY VENTILATORS AIR TREATMENT AND FILTRATION UNITS

Transcription:

OXeN Ductless ventilation with heat recovery www.flowair.com

We are an expert in providing complete heating and ventilation solutions for medium and big cubature buildings. Our offer consists of three main product groups: Air heating and ventilation Air curtains and air curtain-fan heater combo units Ductless ventilation with heat recovery System FLOWAIR is a pioneering solution that enables integration of operation of heating and ventilation units and control their operation with only one controller. Innovative control SYSTEM makes possible to take advantage of features that were previously reserved for extensive building management system BMS. ELiS DUO air curtain-fan heater combo units LEO fan heaters ELiS air curtains OXeN ductless ventilation with heat recovery T-box LEO D destratificators JUST ONE CONTROLLER IS NEEDED control of all units from one place quick access to operating parameters of the units 2 OXeN Ductless ventilation with heat recovery

OXeN Main features Ductless No duct system OXeN is the effective ductless ventilation with direct flow of the air into the occupied zone. OXeN with control system Only 3 elements: OxC wall crossing Air inlet Air outlet Easy maintenance No duct system and easy access to filters and heat recovery exchangers. Thanks to this you will quickly perform maintenance of the unit without the involvement of specialized service companies. OXeN is pure ventilation without burdensome and dirty ducts. Air supply into the room OxS air inlet/outlet Air extract from the room Energy-efficient Lower operation costs Lower investment costs 68,4% efficiency of heat recovery easy to clean and maintenance cheaper boiler cheaper transport and storage boiler 200 kw boiler 120 kw OXeN ventilation units meet all of the requirements of directive no. 2009/125/WE, which establishes a framework of ecodesign requirements for energy-related products. The unit s design provides easy access to the heat recovery exchanger and filter replacement. Reduced energy demand means lower power boiler and pump and cheaper installation. 1 palette = 1 OXeN with all accessories and complete, connected control system. Compact It could not be designed easier. No assembling, matching, fixing. Oxen after removing from the palette is immediately ready for installation. Low weight 67 kg does not require special supporting structures. To install OXeN only one hole in the wall is required. 67kG Equipped as standard with installation holders. OXeN Ductless ventilation with heat recovery 3

OXeN Ventilation unit OXeN Air flow [m³/h] 150 1200 Efficiency of heat recovery [%] up to 78,9 Weight [kg] 67,2 73,4 Casing EPP (expanded polypropylene) Colour grey Application: Medium cubature buildings, where fresh air supply is demanded and where air duct installation is unfounded, e.g. gas stations, stores, workshops, warehouses, sports halls etc. OXeN ventilation unit is: the easiest way to create mechanical ventilation system with heat recovery, the ductless ventilation system, which allow significant reduction of investment costs, the highly-efficient heat recovery system, which reduces operation costs. Available models X2-N-1.2-V unit without additional air heating for installation on the wall X2-W-1.2-V junit with air heating by water heater for installation on the wall X2-N-1.2-H unit without additional air heating for installation under the ceiling X2-W-1.2-H unit with air heating by water heater for installation under the ceiling Dimensions 1180 760 For installation on the wall 1020 For installation under the ceiling 890 1370 830 840 4 OXeN Ductless ventilation with heat recovery

Technical data X2-W-1.2-V X2-N-1.2-V X2-W-1.2-H X2-N-1.2-H Max. air flow stream inlet/outlet (1) [m 3 /h] 1200 Air stream range (2) [m] 15 Air flow regulation inlet/outlet [m 3 /h] stepless, 150 1200 Acoustic pressure level (3) [db(a)] 49 Power supply [VAC/Hz] 230/50 Max. current consumption [A] 1,9 Max. power consumption [W] 420 Type of casing EPP expanded polypropylene Colour (4) grey Weight of unit [kg] 69,6 67,2 72,6 70,2 Weight of unit filled with water [kg] 70,4 73,4 Place of installation indoors Max. air contamination [g/m 3 ] 0,3 Oparating temperature [ o C] 5 45 Installation position vertically on the wall under the ceiling IP 42 Filter class EU4 Type of heat recovery exchanger two-step heat recovery in cross heat exchangers Thermal efficiency dry / wet (5) [%] 68,4 / 78,9 Type of additional heater water heater water heater Nominal heating capacity (6) [kw] 10 10 Air temperature rise (ΔT) (6) [ o C] 25 25 Connection [ ] ½ ½ Max. water pressure [MPa] 1,6 1,6 Max. water temperature [ o C] 95 95 Control system controller with touch screen Antifreeze protection of heat recovery exchanger reduction of fan revs Antifreeze protection of water heat exchanger temperature mesurement of suppied air and water by PT-1000 sensor temperature mesurement of suppied air and water by PT-1000 sensor (1) Max. air flow during operation with EU4 filter and OxS air inlet (2) Range of isothermal air stream, at 0,2 m/s velocity limit (3) Acoustic pressure level at the distance of 5 m from the unit, in the room of medium capability of sound absorption and 500 m 3 of cubature (4) Similar to 9007 (5) According to directive 2009/125/EC measured with balanced mass flow, an indoor-outdoor air temperature difference of 20 K and the airflow 1200m 3 /h (6) At water temperature 80/60 o C, inlet air temperature 5 o C and 1200 m 3 /h of air flow OXeN Ductless ventilation with heat recovery 5

Construction Construction of the unit is a combination of properly selected materials. It is worth to use custom solutions to achieve the desired effect. In this way, we obtained a unique, functional unit. Innovative casing high resistance to damage low weight thermal and acoustic insulation Multi-fan technology steady air distribution quiet operation low power consumption X 2 -flow high efficiency of heat recovery in two cross-flow heat exchangers Supporting structure combination of galvanized steel and plastic high strength while maintaining low weight easy service access Solution worth of awards OXeN heat recovery unit has been recognized as a model for complex designing by the chapters of most prestigious competitions in the world design. Experts praised the project for the quality, selection of materials, innovation, functionality and ergonomics. 2014 6 OXeN Ductless ventilation with heat recovery

Control system OXeN heat revovery unit is equipped with complete control system. Fresh air temperature sensor T-box Controller with touch screen: Intuitive use Quick setting of desired parameters Full control over operating status of the unit Control over up to 31 units simultaneously Integration with FLOWAIR System Cutting-off dampers actuator By-pass actuator Removed air temperature sensor Central power and control system 3-way valve with actuator (only for OXeN X2-W-1.2-V/H) Heating medium temperature sensor (only for OXeN X2-W-1.2-V/H) Supplied air temperature sensor Ambient air temperature sensor Operating modes weekly programmer automatic regulation of supplied air temperature COMFORT / ECO change of operating parameters by one click filters operating time counter antifreeze protection compatibility with BMS MODBUS RTU system operation with or without heat recovery OXeN Ductless ventilation with heat recovery 7

Nomogram of heating capacity for max. air flow 1200 m 3 /h T2 inside temperature [ o C] 5 10 12 14 16 18 20 22 24 0-5 T1 outside temperature [ o C] -10-15 -20-25 -30 1 2-35 -40 3 0 2 4 6 8 10 12 14 16 18 20 Pr heat recovery capacity [kw] Pc total heating capacity [kw] 35 30 25 20 15 10 5 5 4 Temperature of heating medium: Tw1/Tw2 = 90/70 C Tw1/Tw2 = 80/60 C Tw1/Tw2 = 70/50 C Tw1/Tw2 = 60/40 C Tw1/Tw2 = 50/30 C 1. Specify outside temperature 2. Specify inside temperature 3. Read the capacity of heat recovery Pr (total heating capacity of OXeN without water heat exchanger X2-N-1.2) 4. Specify heating medium temperature 5. Read the total heating capacity Pc (for OXeN with water heat exchanger X2-W-1.2) Air parameters: supplied air RH 90%, removed air RH 30%, air flow 1200 m 3 /h 8 OXeN Ductless ventilation with heat recovery

Nomogram of air flow temperature for max. air flow 1200 m 3 /h T2 inside temperature [ o C] 5 10 12 14 16 18 20 22 24 0-5 T4 air flow temperature OXeN X2-W-1.2 [ o C] T1 outside temperature [ o C] -10-15 -20-25 -30-35 -40 45 40 35 30 25 20 15 10 5 1 3-8 -6-4 -2 0 2 4 6 8 10 12 14 16 18 20 5 2 4 T3 air flow temperature OXeN X2-N-1.2 [ o C] Temperature of heating medium: Tw1/Tw2 = 90/70 C Tw1/Tw2 = 80/60 C Tw1/Tw2 = 70/50 C Tw1/Tw2 = 60/40 C Tw1/Tw2 = 50/30 C 1. Specify outside temperature 2. Specify inside temperature 3. Read the air flow temperature for OXeN without water heat exchanger 4. Specify heating medium temperature 5. Read the air flow temperature for OXeN with water heat exchanger Air parameters: supplied air RH 90%, removed air RH 30%, air flow 1200 m 3 /h OXeN Ductless ventilation with heat recovery 9

Installation on the wall OxS OxE OxC OxS wall-mounted air inlet/outlet OxE extension duct OxC wall crossing (one piece as standard with OXeN) Ø15,5 mm Gravitational condensate discharge. Possibility to install the OxS air inlet/outlet on both sides. min. 1,5 m 2,0-4,0 m 10 OXeN Ductless ventilation with heat recovery

Installation under the ceiling OxS-H OxS-H roof-mounted air inlet/outlet OxE-H extension duct OxC2-H connection adapter (in set) OxE-H Tinsmith works and roof seal must be performed. 0,4-1,5 m OxC2-H Ø 9 mm Condensate discharge by built-in pump. 3,0-5,0 m OXeN Ductless ventilation with heat recovery 11

Find out more Call for more information +48 58 627 57 20 charge as per call by call unit gas heaters air heating and ventilation air curtains and air curtain-fan heater combo units fan heaters for agricultural and special purpose buildings Check out YouTube channel watch movies! Visit our website www.flowair.com FLOWAIR ul. Chwaszczyńska 151E, 81-571 Gdynia www.flowair.com Tel. +48 58 627 57 20 Fax. +48 58 627 57 21 inquiries should be directed to the following address: info@flowair.pl