ω = (1) Kirby S. Chapman Ph.D.

Similar documents
ME Mechanical Engineering Systems Laboratory. Experiment 3 - Mass and Energy Balances in Psychrometric Processes

For an ideal gas mixture, Dalton s law states that the sum of the partial pressures of the individual components is equal to the total pressure.

AR/IA/UP 241 Lecture 5: Psychrometrics

Week 4. Gas-vapor mixtures Air conditioning processes. ME 300 Thermodynamics II 1

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

Chapter 14 GAS VAPOR MIXTURES AND AIR-CONDITIONING

Department of Mechanical Engineering ME 322 Mechanical Engineering Thermodynamics

Scientific Principals and Analytical Model. Charcoal Cooler. Lisa Crofoot MECH 425, Queens University

Thermodynamics II Chapter 6 Mixtures & Psychrometry

CE311 Fall 2016 Mid-Term Exam 1

Chapter 14, Problem 27.

Thermo-physical properties found on most psychrometric charts

Optimizing Electric Humidifier Operation with an Air Side Economizer

CE311 Fall 2016 Mid-Term Exam 1

ME 410 MECHA ICAL E GI EERI G SYSTEMS LABORATORY

AND AIR-CONDITIONING. Dr Ali Jawarneh Department of Mechanical Engineering Hashemite University

COMPARING AIR COOLER RATINGS PART 1: Not All Rating Methods are Created Equal

MECHANICAL ENGINEERING THERMAL AND FLUID SYSTEMS STUDY PROBLEMS

Comfort and health-indoor air quality

Module 1: Introduction to Radiant Cooling. Pierre Jaboyedoff

SECTION THIRTEEN HEATING, VENTILATION, AND AIR CONDITIONING

HVAC (Heating, Ventilating, and Air Conditioning)

THE PSYCHROMETRIC CALCULATOR By: Stanley F. Gallos, The Bastian-Blessing Company INTRODUCTION PROPERTIES OF THE RSES CALCULATOR

Institute of Aeronautical Engineering (Autonomous) Dundigal, Hyderabad B.Tech (III II SEM) MECHANICAL ENGINEERING

Chapter 14. At temperatures below the critical temperature, the gas GAS VAPOR MIXTURES AND AIR-CONDITIONING. Objectives

Drying principles and general considerations

R07. Answer any FIVE Questions All Questions carry equal marks *****

CHAPTER 7 PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM IN HYBRID REFRIGERATION SYSTEM

NEW CD WARP CONTROL SYSTEM FOR THE CORRUGATING INDUSTRY

HME09 NATURAL VENTILATION

Chapter 8 Balances on Nonreactive Processes PSYCHROMETRIC CHART

Psychrometrics. Outline. Psychrometrics. What is psychrometrics? Psychrometrics in daily life and food industry Psychrometric chart

Theoretical Performance Analysis Of Direct Evaporative Cooler In Hot And Dry Climates

FS 231: Final Exam (5-6-05) Part A (Closed Book): 60 points

PRINCIPLES OF HEATING, VENTILATION AND AIR CONDITIONING with Worked Examples

Psychrometrics: The Science of Moisture in Air. Presented by Tom Peterson, CEO and Founder. Climate by Design International

SIDDHARTH GROUP OF INSTITUTIONS :: PUTTUR Siddharth Nagar, Narayanavanam Road AUTONOMOUS QUESTION BANK (DESCRIPTIVE) UNIT I

Development of a Psychrometric Test Chamber. Michael J. Swedish. Associate Professor Mechanical Engineering Department Milwaukee School of Engineering

UNIT-III PSYCHROMETRY. Though there are many psychometric terms, yet the following are important from the subject point of view :

Temperature. In the HVAC area, we talk about two kinds of temperatures.

(Refer Slide Time: 00:00:40 min)

ecodry Figure 1 - Process Diagram ecodry B General Process Description

Impact of Multi-Stage Liquid Desiccant Dehumidification in a Desiccant and Evaporative Cooling-Assisted Air Conditioning System

A CEILING CONDENSING UNIT WITH PELTIER ELEMENTS FOR DRYING AND COOLING

Effect of Operating Parameters on the Performance of Direct Evaporative Cooler

EXPERIMENTAL STUDY OF AIR FLOW RATE EFFECTS ON HUMIDIFICATION PARAMETERS WITH PREHEATING AND DEHUMIDIFICATION PROCESS CHANGING

There are (at least) four reasons why you need to understand moisture and humidity in building physics:

Reducing energy use, airstream heat gain, and condensate production

s. Properties for R134a are as follows : Saturated R-134a Superheated R-134a

Air Conditioning Clinic

Mathematical Simulation of Longan Fruit Drying

Design Procedure for a Liquid Dessicant and Evaporative Cooling Assisted 100% Outdoor Air System

Available online at Energy Procedia 6 (2011) MEDGREEN 2011-LB

S.A. Klein and G.F. Nellis Cambridge University Press, 2011

Steam humidification: Reducing energy use, airstream heat gain, and condensate production

ANALYSIS OF DESICCANT COOLING SYSTEM

Article Energy Saving Benefits of Adiabatic Humidification in the Air Conditioning Systems of Semiconductor Cleanrooms

UNIT 1 AIR CONDITIONING 1. Write the various psychometric processes? Explain any four processes with neat sketches?

Armstrong Cool-Fog Systems

OURSE TITLE : MASS TRANSFER OPERATIONS 1 COURSE CODE : 5071 COURSE CATEGORY : A PERIODS/ WEEK : 4 PERIODS/ SEMESTER : 52 CREDIT : 4 TIME SCHEDULE

Don t Turn Active Beams Into Expensive Diffusers

PRESSURE-ENTHALPY CHARTS AND THEIR USE By: Dr. Ralph C. Downing E.I. du Pont de Nemours & Co., Inc. Freon Products Division

Efficiency of Application the Condensing Heat Utilizers in the Existing Boiler's Unit in Heat Power Station

Psychrometric Engineering Applications

Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to Achieve Optimal Closed DOAS Operation

RSES Technical Institute Training Manual 1 70 hours, 70 NATE CEHs, 7.2 CEUs

TECHNICAL NOTE ON EVAPORATIVE COOLING. Renato Lazzarin, President of the IIR s Commission E1

Fig.: macroscopic kinetic energy is an organized form of energy and is much more useful

Desiccant Cooling with Solar Energy

Helicoil and Shell-Tube Heat Exchanger. Abdullah AlThomairi, Ahmed Sajjad, and Faris AlShuaibi. October 25, 2014

Single Zone System. One duct system Used mostly in small buildings Forced air system All spaces controlled by a single thermostat Single air return

CRAWL SPACE MOISTURE CONTROL - A Fundamental Misunderstanding By Peter Carpenter, member ASHRAE, SBCCI

Thermodynamics: Homework A Set 7 Jennifer West (2004)

Fundamentals of Psychrometrics. By James L. Murphy, Colorado Building Environments Sales Engineer

The Basics - B Practical Psychrometrics. Jerry Cohen President Jacco & Assoc.

Reducing energy consumption of airconditioning systems in moderate climates by applying indirect evaporative cooling

Atmospheric Moisture: Relative Humidity and Dew Point

Residential ventilation concepts based on the idea of displacement airflow distribution

Cooling Load Analysis and Computation Worksheet

ASHRAE JOURNAL ON REHEAT

Cooling Load Analysis and Computation Worksheet Answers Part 1 Psychrometrics

Open and Closed Door Moisture Transport and Corresponding Energy Consumption in Household Refrigerator

Reducing energy use, airstream heat gain, and condensate production

Bharathidasan University (Accredited by NAAC at A level) Tiruchirappalli

Paper No. : 04 Paper Title : Unit Operations in Food processing Module 11 : Principles of Refrigeration

A/C Cooling Load calculation and measurement

AIR CONDITIONING. Carrier Corporation 2002 Cat. No

Reducing energy use, airstream heat gain, and condensate production

The Use Of Attic Space For Cooling and Dehumidification

Experimental Study of Direct Contact Condensation of Steam on Water Droplets

UNIT - 3 Refrigeration and Air - Conditioning

Redesign of Bennett Hall HVAC System

COOLING ENERGY SAVING SYSTEM USING A WATER MIST DEVICE ON WINDOWS

MIXING RATIO AND ABSOLUTE HUMIDITY

Optimization of Hybrid Noncondensable Gas Removal System for a Flash Steam Geothermal Power Plant

Conductive Heating Technologies for Medical Diagnostic Equipment. Russell Strehlow, Manager of Research and Development, Minco

TOTAL SYSTEM EFFICIENCY: AN INTRODUCTION TO CONDENSING BOILERS. David Grassl PE Mechanical Engineer Principal

Hygrometry. The art or science of humidity observation

SBS5311 HVACR II Experiment 2: Analysis of the Combined Rankine and Vapour Compression Cycle

Design of a Low capacity Evaporator of a Refrigeration Unit

Transcription:

White Paper: Relative Humidity Impacts of the AirFloor System in the Built Environment Kirby S. Chapman Ph.D. kirby.chapman@scavengetech.com Introduction Relative humidity is specified as one of the seven thermal comfort parameters in ASHRAE Standard 55. Figure 1 shows the relationship between relative humidity, the dew-point temperature, the operative temperature, and thermal comfort. The thermal comfort ranges are based on the Predicted Mean Vote (PMV) of 80% acceptability. Figure 1 illustrates that relative humidity plays an important role in whether or not an individual feels thermally comfortable. Unfortunately, the relative humidity is a function of the local temperature as well as the mass of water vapor contained in the air. This white paper first explains the thermodynamic principles that govern relative humidity. The discussion then evolves to explain how relative humidity is impacted by various heating and cooling systems within the built environment, specifically the AirFloor system. Figure 1. Thermal comfort chart from ASHRAE Standard 55. Humidity thermodynamic principles Humid air is typically treated as a homogeneous mixture of dry air and water vapor. While the composition of dry air remains constant, the concentration of water vapor within the air depends on evaporation, condensation, and mixing of humid air volumes. There are two common methods to quantify the concentration of water vapor contained within the air: humidity ratio and relative humidity. The humidity ratio is only a function of the mass of water vapor and mass of dry air. The humidity ratio is mathematically defined as: mv ω = (1) ma The term m a is the mass of air and the term m v is the mass of water vapor. The only way to change the humidity ratio is to change the mass of water vapor in the air. Humidification and de-humidification systems accomplish this task. The right vertical axis in Figure 1 represents the humidity ratio. By assuming that water vapor and dry air can be modeled as ideal gases, the humidity ratio is calculated from the barometric pressure and the partial pressure of the water vapor: K.S. Chapman Page: 1 of 6

0.622 p ω = v p p v The number 0.622 is the ratio of the water vapor molecular weight to the molecular weight of air. The term p is the barometric pressure and the term p v is the partial pressure of the water vapor. The water vapor partial pressure is typically a small number less than 0.5 psia. The second water vapor metric, the relative humidity, is more commonly used and referred to in HVAC conversations. However, as shown in the following discussion, the relative humidity is a function of the mass of water vapor and the dry air temperature. The definition of the relative humidity is the ratio of the mass of water vapor to the mass of water vapor that would exist at saturated conditions. The mass of water vapor at saturated conditions is the maximum quantity of water that the air can hold at the dry-bulb temperature without condensation. The mathematical definition of relative humidity is: mv φ = (3) m g The new term m g is the mass of water vapor at saturated conditions. Substituting the ideal gas law into equation (3) results in the typical mathematical description of the relative humidity: pv φ = (4) p g The term p g is the saturation pressure at the local dry bulb air temperature. Figure 2 shows the relationship between the local dry bulb temperature and the saturation pressure of water. By comparing equations (2) and (4), one sees that the numerator in equation (4) is a function of the mass of water vapor in the air and the denominator in equation (4) is a function of the local dry-bulb temperature. Consequently, the relative humidity is a function of the mass of water vapor in the air and the local dry bulb temperature of the air. Finally, the relationship between the humidity ratio and the relative humidity is derived by substituting equation (4) into equation (2): ω p φ = (5) ( 0.622 + ω) pg The humidity ratio is determined by measuring the wet bulb and the dry bulb air temperatures. The wet bulb temperature is measured using a psychrometer, and is approximately equal to the adiabatic saturation temperature of humid air. The end result is a functional relationship between the wet bulb temperature, the dry bulb temperature, the barometric pressure, and the humidity ratio. Referring again to equation (4), the relative humidity is a measure of how full the air is of water. For example, if the relative humidity is 50%, then the drive for evaporation is stronger than it would be if the relative humidity were 75%. (2) K.S. Chapman Page: 2 of 6

Impact of Relative Humidity on Thermal Comfort Because relative humidity is a measure of the drying ability of humid air, it has a direct impact on whether or not a person feels cold or warm. The two cases are summer (cooling season) and winter 1.0 0.9 y = 2E 06x 3 0.0002x 2 + 0.0114x 0.1726 R² = 1 Water Saturation Pressure (psia) 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.0 50 55 60 65 70 75 80 85 90 95 100 Dry Bulb Temperature ( F) Figure 2. Saturation pressure as a function of dry-bulb temperature. (heating season). Summer/Cooling Season In the summer, the body s mechanism for staying cool is to perspire. The rate of perspiration is limited by evaporation from the skin surface to the surrounding air. The evaporation rate is limited by the ability of the humid air to take on more water. The evaporation rate, which is a mass transfer mechanism, is inversely proportional to the relative humidity, i.e., the evaporation rate is greater for a lower relative humidity than it is for air with a higher relative humidity. Consequently, if the relative humidity is high, then the evaporation rate is reduced, and the body s ability to cool itself through perspiration is limited. Conversely, if the relative humidity is low, then the evaporation rate is higher and the body can more effectively control thermal comfort. Referring to Figure 1, the relative humidity must stay below approximately 60% to achieve a thermally comfortable environment at almost any operative temperature. However, 80% of the occupants will feel thermally comfortable at an operative temperature between approximately 74 F and 80 F. K.S. Chapman Page: 3 of 6

Winter/Heating Season In the winter, the body s mechanism for staying thermally comfortable is completely different than during the cooling season. In the winter, one of the more problematic issues is that the air is too dry, i.e., the relative humidity is too low. When the relative humidity is too low, the sinus cavities become dry and, if too dry, can begin to bleed. Most sources, including Figure 1, suggest that the relative humidity be maintained at least above 30% and preferably higher. Impact of HVAC Systems on Humid Air As explained above, the only way to change the humidity ratio of humid air is to change the ratio of the mass of water to the mass of dry air. The three pertinent methods that can accomplish this task are: 1. Physically add water to the air through a humidification mechanism; 2. Physically remove water from the air through a de-humidification mechanism; and 3. Mix two humid air masses that have different humidity ratios. Winter/Heating Season The main contributor to dry air in the built environment during the heating season is infiltration of outside air. Unfortunately, infiltration is difficult to quantify without employing some type of pressurized test method. However, infiltration has been shown to be impacted by the heating system. Typically, systems with higher discharge air temperatures will create the possibility of having a higher stack effect in the building, which then leads to higher infiltration rates. Additionally, the use of a fan to move air throughout the building creates an inside pressure that is typically higher than the outside pressure. The result is the exchange of inside and outside air. When outside air enters the built environment, its temperature increases to that of the inside air. The problem, as it pertains to relative humidity, is that the relative humidity of the infiltrated air decreases significantly when it is heated to the inside air temperature. For example, if the outside air conditions are 32 F at a relative humidity of 60%, when this air enters the built environment and subsequently heats to a temperature of 70 F, the relative humidity of that air decreases to only 14.7%. Consequently, higher infiltration rates lead to lower indoor relative humidity levels. When this concept is applied to the AirFloor system, the AirFloor system functions as part radiant, part forced-air systems. The radiantly heated floor acts to increase the operative temperature while the lower diffuser discharge temperature decreases the infiltration rate when compared to a conventional forced air heating system. Consequently, a plausible argument can be made that the Airfloor system creates a more thermally comfortable environment because (1) it acts to increase the operative temperature and (2) acts to maintain a comfortable relative humidity level. The second aspect of the AirFloor system when compared to a conventional forced-air heating system is that the temperature of the air exiting the diffuser is significantly lower for the AirFloor system. This lower temperature is due to the transfer of heat from the heated air through the AirFloor system as radiant energy. The ultimate impact on the room occupants is a higher, more comfortable, relative humidity of the air exiting the diffuser. Referring again to Figure 1, a conventional heating system can only increase the operative temperature by increasing the actual room air dry-bulb temperature (Watson and Chapman, 2001). The end result is a room relative humidity that is plausibly less than the lower comfort limit of 30%. The AirFloor system operates differently by transferring a large percentage of energy from the heated K.S. Chapman Page: 4 of 6

air through the AirFloor system. A percentage of this energy is then transferred to the occupants by radiant exchange, which effectively increases the operative temperature without heating the air to as high a temperature. The result is a higher relative humidity at a given operative temperature when compared to that of a conventional heating system. Summer/Cooling Season As explained above, the thermal comfort physics are completely different for cooling than they are for heating. The main contributor to discomfort during cooling is the water vapor contained within the air, i.e., high relative humidity. Infiltrating air during the summer months is cooled to room temperatures, which increases the room relative humidity. Much of the energy used to condition the air in the occupied space during cooling is used to remove water vapor from the air. By definition, the air becomes saturated in the conditioning unit such that the relative humidity of the air leaving the conditioning coil is at 100%. In a conventional system, the conditioned air gains some energy in the duct before it is delivered to the room. However, the increase in temperature is modest at approximately 58 F, which means that the air entering the room through the diffuser is at a relative humidity of nearly 100%. In the AirFloor system, the air extracts heat from the AirFloor structure. This extraction impacts thermal comfort in two ways. First, the floor surface temperature is cooler than the surrounding air. The occupants radiatively exchange energy with the floor, which lowers the operative temperature without significantly lowering the room dry-bulb temperature. Second, the air flowing through the AirFloor system is heated to approximately 68 F. This increase in temperature decreases the relative humidity from the nearly 100% in the conventional cooling case to something that is more amenable to creating a thermally comfortable space. Conclusions The AirFloor system functions in a way that moderates the relative humidity while at the same time creating a positive influence on the operative temperature. This effect is shown in Figure 3. The blue star illustrates the approximate condition of the air coming from the conventional forced air diffuser in cooling mode and the red star illustrates the corresponding condition in heating mode. Conversely, the AirFloor system will create a condition where the air exiting the diffuser will be in the shaded areas, or at least very near the shaded areas. Hence, the AirFloor system should require less energy to achieve the same level of thermal comfort when compared to a conventional forced-air heating and cooling system. The definitions and discussion in this white paper clearly show that relative humidity and thermal comfort are not a given, but instead are a strong function of the method used to condition (heating or cooling) in the occupied space. ASHRAE Standard 90.1 has recently recognized this fact. The findings from ASHRAE Standard 90.1 are forthcoming in the new standard. These findings clearly show that radiant systems create a thermal comfort Figure 3. Thermal comfort chart from ASHRAE Standard 55. K.S. Chapman Page: 5 of 6

moderating effect. When a hybrid system, such as the AirFloor system, is employed, it can also moderate relative humidity in a way that increases relative humidity during the heating season and lowers relative humidity during the cooling season. This impact is due to the recognition of operative temperature as the thermal comfort metric instead of the historically used dry-bulb temperature. In turn, the operative temperature can be controlled with a moderating impact on the relative humidity. References Watson, R.D, and Chapman, K.S., 2002, Radiant Heating and Cooling Handbook, McGraw- Hill, New York, New York. Moran, M.J. and Shapiro, H.N., 2008, Fundamentals of Engineering Thermodynamics, John Wiley and Sons. K.S. Chapman Page: 6 of 6