PORT700CF Portable Fume Collector

Similar documents
AVANI Grinding Booth

OWNER S MANUAL #DC2000Y #DC2000YCF 2 HP, 1500 CFM DUST COLLECTOR. VERSION 1 -w/ 6 INLET PORT. Model #DC2000Y Global Rd.

Pump Out Vacuums Polyethylene & Steel

690 and Power Fishing Systems

User s Manual and Operating Instructions

3HP MOBILE CYCLONE DUST COLLECTOR MANUAL FILTER CLEANING MANUAL

7165 Dust Collector Owner s Manual

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

BIOCIDE ANTIMICROBIAL DRY VACUUM

WET/DRY VACUUMS POLYETHYLENE, POLYPROPYLENE & STEEL

5HP CYCLONE DUST COLLECTOR MANUAL

Republic Blowers. Ring Blower Side Channel Blower Regenerative Owner s Manual

Canister Vacuums S6EVO. Operations and Parts Manual. Models: S6EVO

P4000 Construction Heater

Operating Instructions for the BBO-1 and BBO-2 Basket Blasters

Flood Pumper Plus. Water Transfer Machine. Operator and Parts Manual. Model No.: Rev. 00 (11-99)

DOWNDRAFT TABLE SERIES SCT

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS

Operations and Parts Manual

Wet/Dry Vacuums Polyethylene, Polypropylene, & Steel

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS

SPECIFICATIONS FEATURES

Operating Instructions (ENG) MODEL: 115 V UL LISTING FOR 1/2 HP MODELS ONLY. Read instructions before operating the machine J 07/05/07

OWNER S MANUAL #DC2000B #DC2000BCF

Installation and Operation Manual. 445 Procedures Cart. Page 3. Page 5. Page 8. Page 10. Important Information Page 2. Installation.

User s Manual and Operating Instructions

OPERATOR S MANUAL. For BURLY ATTACHMENTS

Installation Instructions Dual Fuel Ranges

INSTALLATION GUIDE Dual Fuel Ranges

Model PF 2030 Wide Area Vacuum Cleaner

SSS Speedster 600 (Model SP-600, #56001) SSS Speedster 1000 OPERATION SERVICE PARTS CARE. SSS Speedster 1000 SSS Speedster 600

AeroVent 1 Product Manual

690 Power Fishing System

GRIND PRO DUAL OR DISC SANDER. Operator Manual

Store Name: Location: Date Purchased: Serial Number (located on back of unit):


Operating Instructions

KUFO/SECO DUST COLLECTOR

AeroVent 3X Product Manual

JOB EXTRACTOR OPERATIONS MANUAL REV A

AURA WIDE AREA VACUUM Parts Manual

55-Gallon Dispenser Package

WARNING USER S MANUAL. Model iq 2000 Series Dust Collector with manual shaker

User Manual AIR HOG. Vacuum Booster REV. 3/20/ Stowe Dr. Poway, CA P: (858) F: (858)

ACT Cartridge Dust Collector

MC MC MC MC MC833130

Installation and Maintenance Manual Please retain this manual for future reference.

OPERATIONS MAINTENANCE MANUAL

2HP MOBILE CYCLONE DUST COLLECTOR MANUAL

Parts & Operations Manual

AeroVent Standard Product Manual

Model : CHB Series CHUNGHO C.A. CO., LTD. Head office / Factory Seowoon-Dong, Gyeyang-Gu, Incheon, Korea. com

hp Dust Collector With Vacuum Attachment

MAYFIELD CEILING FAN LISTED E ITEM # MODEL #BTH44ABZC5C BTH44BNK5C Español p. 20 ATTACH YOUR RECEIPT HERE.

IMPORTANT SAFETY INFORMATION

Installation and Operation Manual CLEARVIEW DAY COVER CAUTION: To view a video scan the QR code above

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

HEAVY-DUTY WELDING CART USER S MANUAL

Owner s Manual & Safety Instructions

PORTABLE DEHUMIDIFIER

BASEBOARD MICATHERMIC HEATER

INSTRUCTION MANUAL MODEL: 690E

Operator s Manual. 6 Gallon Model No. VQ607SFD FOR YOUR SAFETY. Read and understand this manual before use Keep this manual for future reference

INSTRUCTIONS FOR TAL SERIES VACUUM HOPPER LOADER

Installation Instructions Remote Blowers

VF/VG700 Jumbo. Construction Heater. Installation and Maintenance Manual

CINCINNATI, OH USA

user manual Model #: BLZ-WVH-42

12,000 BTU Evaporative Portable Air Conditioner

Service Parts, Kits and Accessories

WAV-30 WIDE AREA VACUUM

PILEJOGGER II MODELS: PJ2A PJ2AIE Operating Instructions (ENG) Read instructions before operating the machine.

Electronic Service Manuals

Retrofit Instructions for Tower Dryer Moisture Sampler Blower Kit

COBRA -H EXTRACTOR 120V

Instruction Manual. Astro Staging Cabinet

WET/DRY VACUUM. QUEST for Continuous Improvement Windsor s Quality Management System is Certified ISO MODEL: T1. Operating Instructions (ENG)

LITTLE BLASTER SET-UP INSTRUCTIONS FOR SHOT PEEN MACHINES WITH CARTRIDGE TYPE DUST COLLECTORS *** READ BEFORE OPERATING EQUIPMENT***

OWNER'S MANUAL IMPORTANT: READ OWNER'S MANUAL CAREFULLY MODEL : CHEETAH DC2000 FOR YOUR CONVENIENCE, RECORD THE FOLLOWING IMPORTANT INFORMATION MODEL:

1 HP Air Mover. Owner s Manual

Operating Instructions (ENG) MODEL: AM115V. Read instructions before operating the machine. AM /24/00

Retrofit Instructions CLEARVIEW DAY COVER CAUTION: Please read this manual completely before attempting to install, operate or service this equipment

The Danger signal indicates an immediately hazardous situation which, if not avoided, will result in death or serious injury.

Operations and Safety Manual

Cat 5 Pro Vacuum OPERATOR S MANUAL

Hardwired Electric Garage Heater

Indoor/Outdoor Electric Patio Heater Model No: HP Operating Instructions HP Soleus Air International

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor 2kW RETHERMALIZER

ELSTON 52 CEILING FAN

USER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES

INSTRUCTION MANUAL 4HP WET / DRY VACUUM VC V 60 Hz 7A. Gal


Contents. 11. Preamble. 12. For the safe use. 13. Appearance. 14. Connecting the sources of electricity. 15. Caution for use before the operation.

W Model 1RKU2 w/optional Wall mount. Unit Model Weight (Lbs) Kilowatts Volts- Phase Amps Fan Output Heat Output

Sanitaire. Owner s Guide. 10 GALLON Box Extractor SC6088 Series IMPORTANT

BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

MANUAL FOOD HOLDING & TRANSPORT CABINETS WITTCO MODEL NUMBERS

60In. Ceiling Fan. Owner s Manual

PS /2 Inch Angle Grinder Assembly & Operating Instructions READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT.

User s Manual WS-69TB30 / WS-69TB36 (22 ) WS-69TB42 / WS-69TB48 (22 ) WS-69TS30 / WS-69TS36 (18 ) WS-69TS42 / WS-69TS48 (18 )

Transcription:

11975 Portland Ave. S. Suite 104 Burnsville, MN 55337 Phone: 952-894-6637 Fax: 952-894-0750 Email: info@ventaire.com Website: www.ventaire.com PRODUCT GUIDE FOR PORT700CF Portable Fume Collector REV:110314 Page 1 of 22 Ventaire 2011

TABLE OF CONTENTS MACHINE WARNING SIGNS... 3 TECHNICAL SPECIFICATIONS... 4 INSTALLATION SAFETY PRECAUTIONS... 5 ELECTRICAL INSTALLATION... 5 ELECTRICAL CIRCUIT DIAGRAM... 6 ELECTRICAL VOLTAGE CHANGE... 8 OPERATION SAFETY INSTRUCTIONS... 9 OPERATION INSTRUCTIONS... 9 MAINTENANCE AUTOCAD DRAWING... Error! Bookmark not defined. FILTER IDENTIFICATION & ASSEMBLY... 10 Filters... 10 Filter Assembly... 10 Magnetic Switch Replacement... 13 PARTS LIST Repair Parts Illustration... 17 Repair Parts List... 18 Warranty... Error! Bookmark not defined.4 REV:110314 Page 2 of 22 Ventaire 2011

General Safety Information MACHINE WARNING SIGNS Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. Used without the safety alert symbol ( ) indicates potentially hazardous situation which, if not avoided, may result in property damage. Warning of electric shock Do not expose the equipment to rain or use in damp locations. Do not use the equipment around flammable products, if not avoided, sparks can ignite vapors from flammable products. Read and understand all warnings and operating instructions before using this equipment. Failure to follow all instructions may result in electric shock, fire, and/or serious personal injury or property damage. REV:110314 Page 3 of 22 Ventaire 2011

TECHNICAL SPECIFICATIONS Motor Specs: Electrical Specs: Air Volume: Inlet Size: Packing Size: (L x W x H) N.W. (machine): 1.5 HP 120V / 60Hz / 1Ph 900CFM @ Base 6 Dia. 42.5 x 35.8 x 70.1 398 lbs Filter Media Carbon Filter Aluminum Mesh Cartridge Filter 107.6 ft2 Part# PS-150-61 Part# PS-150-77 Part# PS-150-81 REV:110314 Page 4 of 22 Ventaire 2011

INSTALLATION SAFETY PRECAUTIONS Read this Manual carefully before installing and operating the product and maintain a copy on site for reference. Have a qualified electrician install and service this equipment. Do not touch electrically live parts such as internal wiring. ELECTRIC SHOCK can kill. Have a qualified electrician install and service this equipment. Do not touch electrically live parts such as internal wiring. Insure all source power is turned off and locked out before electrical installation. 1. Check that the voltage, phase count and grounding wire match the machine requirements. 2. Check that the electrical specifications of this machine meet safety requirements, and that maintenance is carried out by a certified electrician. 3. Confirm that the parts/accessories have been fully assembled to insure safe and reliable machine operation. 4. Due to the weight of the unit, great care must be taken when moving to avoid injury. Use lifting and transport equipment as necessary. ELECTRICAL INSTALLATION Do not disconnect the wiring jack before turning off power! Electrical installation should be performed within the following conditions: Ambient temperature: Between 41 F and 131 F. If the time is over 24 hours, then the ambient average temperature shall not be over 122 F. Humidity: Between 30% and 95% Altitude: 3,280 feet Moving and Storing: -13 F to 131 F. For short-time storage (less than 24 hours), the storage temperature can be up to 158 F. POWER CONNECTION 1. All electrical connections must be performed by a qualified electrician. 2. Confirm that the available power supply is equal to the motor and control panel voltage and amperage requirements (see installation-technical specifications) 3. Insure that all power supplies are turned off and locked out prior to any connection to the unit. 4. Refer to the electrical diagram (next page) for proper connection. ELECTRIC SHOCK CAN KILL. REV:110314 Page 5 of 22 Ventaire 2011

INSTALLATION ELECTRICAL CIRCUIT DIAGRAM REV:110314 Page 6 of 22 Ventaire 2011

INSTALLATION ELECTRICAL VOLTAGE CHANGE High Voltage 3 2 Low Voltage 3 2 1 4 ~ Line 1 4 ~ Line 1. Open the top maintenance door. 2. Look for the motor junction box. (1) This unit is prewired at the factory for 120 volt, 60Hz, 1-phase operation. (See above wiring diagram.) (2) It can be wired for 220 volt, 60Hz, 1-phase operation. (See above wiring diagram.) For high voltage operation, the 120V control box must be exchanged for a higher volt control box and installed on unit. (3) Have a qualified electrician install properly and connect wiring to control box in accordance with local and national codes. (4) Test the unit to be sure motor fan rotates in direction of rotation arrow. Switch any two leads (not Ground) to reverse rotation if needed. 3. Unscrew the motor junction box. 4. Voltage Change Diagram: 5. Secure the motor junction box with screws.

6. Close the top maintenance door. Assembly completed. OPERATION SAFETY INSTRUCTIONS The Welding Fume Extractor can be dangerous if it is operated incorrectly. Therefore, the product must be used with caution to avoid risk of injury and avoidable hazard or damage. Unnecessary injuries may occur by failing to follow the instructions within Manual. The following components are key to a safe workplace and safe operation of the fume extractor. for repair. 5. Before replacing parts, turn the machine off and shut off power at the source. 6. Do not operate the product near flammable materials, as sparks may ignite these materials and cause an explosion. 7. Key components of the machine run at high speeds and can cause injury. Never place hands, body parts or foreign objects near moving parts. Do not wear loose clothing that can become entangled in moving parts. OPERATION OPERATING INSTRUCTIONS 1. Insure that the working environmental is suitable for using the product. 2. Do not store or use flammable gas or liquids near the machine when in operation. 3. All non-operating personnel should keep proper distance from the unit when in use, to avoid risk of injury. Keep other persons away from the product, except for the operator, to avoid danger. 4. Inspect the electrical wires daily. If wiring is frayed or cut, immediately turn off the unit and turn off the power source and contact a qualified electrician The Welding Fume Extractor is designed for the filtration of smoke generated during ordinary welding process work. When installed and operated correctly, the machine will effectively collect and screen the smoke yielding a significant improvement in air quality within the working environment. 1. Before starting the machine, be sure to read this Manual carefully. 2. Before starting the machine, insure that relevant safety protection measures have been taken according

to the Manual. 3. Before starting the machine, confirm the motor is turning in the direction as labeled on the machine. OPERATION 1. Attach compressed air to the unit for cleaning purposes, at a source pressure of 90 PSI. 2. Refer to control panel (above) for initiating power to the motor and subsequent vacuum from the unit. 3. The vacuum hood should be placed an approximate distance of 12 from the smoke source for efficient operation. 4. The pulse cleaning button is used for filter cleaning and for maximum effectiveness should be used as follows: - The unit should be powered off and the button pushed one to two times. - Cleaning as noted above should be daily or as any decrease in vacuum is observed. 5. If operating vacuum is weak after manual pulse cleaning, remove the metal filter, clean with water and re-install. 6. If vacuum remains weak after cleaning the metal filter, contact AVANI for filter replacement. (see contact list in this manual) Filters 1. aluminum mesh 3. carbon filter 2. cartridge filter Figure 2 - Filters 1. ALUMINUM MESH captures sparks and steel chips. (1) specification: 17.3 x 21.3 x 0.87 (2) filter efficiency: 25 ~ 30% 2. PLEATED CARTRIDGE FILTER that can be cleaned by push-button pulse-jet cleaning of the cartridge filter from an onboard air tank. (1) specification: Ø12.8 x 23.6 (2) quantity: 1 pc 3. CARBON FILTER cleans noxious fumes to provide a better working environment. (1) specification: 17.3 x 21.3 x 0.87 (2) filter efficiency: 25 ~ 30% Filter Assembly Aluminum mesh: MAINTENANCE FILTER IDENTIFICATION & ASSEMBLY

1. Pull out the aluminum mesh and dispose of it properly. Install with a new one. 3. Pull down the left and right filter handles. Cartridge filter installation procedure: 4. Pull out the cartridge filter. 1. Open the front maintenance door. 2. Loosen the screws and washers (circled in green). Release the filter handle fixing plate. filter tray 5. Unfasten the filter tray and install with a new cartridge.

Carbon filter: 6. Slide the cartridge into the track and push it to the end. 1. Release (2) knobs. 7. Pull up the left and right filter handles. 2. Pull out the carbon filter. Insert a new filter and secure it with (2) knobs. 8. Attach the filter handle fixing plate upon the left and right filter handles. Fasten the plate and handles with screws and washers. 3. Close the front maintenance door. Assembly completed

MAINTENANCE Magnetic Switch Replacement Procedure: 3. Dismantle L1 (in black) and L3 (in white) of the main power supply. Remove the Y-shape grounding (in green). 1. Release the upper and lower screws of the magnetic switch. 4. Take away the lower plastic cover. 2. Open the switch cover and loosen the upper and lower screws to move out the whole magnetic switch. 5. Dismantle L1 (in black) and L3 (in white) of the motor power supply. Remove the Y-shape grounding (in green). REV:110314 Page 13 of 22 Ventaire 2011

8. Put back the lower plastic cover. 6. Remove the whole set and replace with a new magnetic switch. 9. Fasten L1 (in black) and L3 (in white) of the main power supply. Secure the Y-shape grounding (in green). 7. Connect L1 (in black) and L3 (in white) of the motor power supply. Link the Y-shape grounding (in green).

13. Look for the motor junction box. 10. Fix the white plastic cover of the contactor. Put the control switch in position. Lock the upper and lower screws. Put back the switch cover. 14. Unscrew the motor junction box. 15. Voltage Change Diagram: High Voltage 3 2 Low Voltage 3 2 11. Fasten the upper and lower screws of the magnetic switch. 1 4 ~ Line 1 4 ~ Line 12. Open the top maintenance door. (1) This unit is prewired at the factory for 120 volt, 60Hz, 1-phase operation. (See above wiring diagram.) (2) It can be wired for 220 volt, 60Hz, 1-phase operation. (See above wiring diagram.) For high voltage operation, the 120V control box must be exchanged for a higher volt control box and installed on unit. (3) Have a qualified electrician install properly and connect wiring to control box in accordance with local and national codes.

(4) Test the unit to be sure motor fan rotates in direction of rotation arrow. Switch any two leads (not Ground) to reverse rotation if needed. 16. Secure the motor junction box with screws. 17. Close the top maintenance door. Assembly completed.

Repair Parts Illustration

PARTS Repair Parts List Please provide following information: -Model number -Serial number (if any) -Part description and number as shown in parts list Reference Number Description Part Number Quantity 1 Back Motor Cover A02-02-PS-150-1 1 2 Flat Washer (1/4"xOD19x2t) A02-02-PS-150-2 22 3 Lower Front Motor Cover A02-02-PS-150-3 1 4 Front Motor Cover A02-02-PS-150-4 1 5 Phillips Head Sheet Metal Screw (5/32"x3/4") A02-02-PS-150-5 2 6 Magnetic Switch A02-02-PS-150-6 1 7 Motor A02-02-PS-150-7 1 8 Motor Gasket A02-02-PS-150-8 1 9 Hex Screw (5/16"x3/4") A02-02-PS-150-9 12 10 Flat Washer (5/16"xOD18x2t) A02-02-PS-150-10 12 11 Motor Base A02-02-PS-150-11 1 12 Lock Washer (5/16") A02-02-PS-150-12 4 13 Hex Screw (5/16"x3/4") A02-02-PS-150-13 4 14 Impeller A02-02-PS-150-14 1 15 Flat Washer (5/16"xOD30x3t) A02-02-PS-150-15 1 16 Hex Screw (5/16"x3/4") A02-02-PS-150-16 1 17 Blower A02-02-PS-150-17 1 18 Magnetic Valve A02-02-PS-150-18 1 19 Nipple Connector A02-02-PS-150-19 1 20 Air Tank A02-02-PS-150-20 1 21 Bushing (3/4"x1/4") A02-02-PS-150-21 1 22 Connector A02-02-PS-150-22 1 23 Dehumidifier A02-02-PS-150-23 1 24 Connector A02-02-PS-150-24 1 25 Connector (1/4") A02-02-PS-150-25 1 26 Switch Valve A02-02-PS-150-26 1 27 Hex Screw (5/16"x3/4") A02-02-PS-150-27 4

Reference Number Description Part Number Quantity 28 Flat Washer (5/16"xOD18x2t) A02-02-PS-150-28 6 29 Fixing Base for Air Tank A02-02-PS-150-29 1 30 Elbow (1/4") A02-02-PS-150-30 1 31 Nipple Connector A02-02-PS-150-31 1 32 Hex Nut (5/16") A02-02-PS-150-32 2 33 Safety Valve (1/2") A02-02-PS-150-33 1 34 Connector A02-02-PS-150-34 1 35 Connector A02-02-PS-150-35 1 36 Connector A02-02-PS-150-36 1 37 Phillips Head Sheet Metal Screw (5/32"x1/2") A02-02-PS-150-37 3 38 Pipe Connecting Base A02-02-PS-150-38 1 39 Button Head Screw (1/4"x3/4") A02-02-PS-150-39 22 40 Connector A02-02-PS-150-40 1 41 Connector A02-02-PS-150-41 1 42 Connector A02-02-PS-150-42 1 43 Connector A02-02-PS-150-43 1 44 Cap A02-02-PS-150-44 1 45 Button Head Screw (1/4"x3/4") A02-02-PS-150-45 14 46 Arm Port Cover (6 ) A02-02-PS-150-46 2 47 Arm Port Cover (8") A02-02-PS-150-47 1 48 Foam Tape A02-02-PS-150-48 1 49 Foam Tape A02-02-PS-150-49 1 50 Machine Body A02-02-PS-150-50 1 51 Hex Nut A02-02-PS-150-51 2 52 Flat Washer (3/8"xOD23x2t) A02-02-PS-150-52 2 53 Handle A02-02-PS-150-53 1 54 Cap Screw A02-02-PS-150-54 2 55 Knob (1/4"x3/4") A02-02-PS-150-55 8 56 Phillips Head Sheet Metal Screw (5/32"x1/2") A02-02-PS-150-56 9 57 Spring Dual Buckle A02-02-PS-150-57 3 58 Casters (6") A02-02-PS-150-58 2 59 Caster Axle Washer A02-02-PS-150-59 1 60 Caster Axle A02-02-PS-150-60 1 61 Activated Carbon Filter A02-02-PS-150-61 1

Reference Number Description Part Number Quantity 62 Drawer (large) A02-02-PS-150-62 1 63 Hex Nut A02-02-PS-150-63 4 64 Foam Tape A02-02-PS-150-64 1 65 Drawer Handle A02-02-PS-150-65 2 66 Drawer Lock A02-02-PS-150-66 3 67 Drawer (small) A02-02-PS-150-67 1 68 Foam Tape A02-02-PS-150-68 1 69 Knob (5/16"x3/4") A02-02-PS-150-69 2 70 Flat Washer (5/16"xOD18x2t) A02-02-PS-150-70 2 71 Filter Handle Fixing Plate A02-02-PS-150-71 1 72 Filter Handle (left) A02-02-PS-150-72 1 73 Filter Handle (right) A02-02-PS-150-73 1 74 Casters w/ brakes (5") A02-02-PS-150-74 2 75 Flat Washer (5/16"xOD18x2t) A02-02-PS-150-75 8 76 Hex Screw (5/16"x3/4") A02-02-PS-150-76 8 77 Aluminum Mesh A02-02-PS-150-77 1 78 Filter Tray A02-02-PS-150-78 1 79 Handle A02-02-PS-150-79 1 80 Cap Screw (5/16"x3/4") A02-02-PS-150-80 2 81 Cartridge Filter A02-02-PS-150-81 1 82 Door A02-02-PS-150-82 1 83 Phillips Head Sheet Metal Screw (5/32"x1/2") A02-02-PS-150-83 6 84 Spring Dual Buckle A02-02-PS-150-84 3 85 Foam Tape A02-02-PS-150-85 1 86 Flange Nut A02-02-PS-150-86 16 87 Roller Chain A02-02-PS-150-87 4 88 Cap Screw A02-02-PS-150-88 16 89 Hex Screw (3/8"x3/4") A02-02-PS-150-89 1 90 Blast Gate A02-02-PS-150-90 1 91 Hex Nut (3/8") A02-02-PS-150-91 1 92 Button Head Screw (5/16"x3/4") A02-02-PS-150-92 14 93 Blast Gate Connector A02-02-PS-150-93 1 94 Blast Gate Gasket A02-02-PS-150-94 1 95 Blast Gate Base A02-02-PS-150-95 1 96 Hex Screw (3/8"x3/4") A02-02-PS-150-96 4

Reference Number Description Part Number Quantity 97 Flat Washer (3/8"xOD23x2t) A02-02-PS-150-97 8 98 Hex Nut (3/8") A02-02-PS-150-98 4 99 Strain Relief A02-02-PS-150-99 3 100 Manual Air Pulse Jet Button A02-02-PS-150-100 1 101 Foam Tape A02-02-PS-150-101 1 102 Compression Latch Base A02-02-PS-150-102 2 103 Round Phillips Head Screw (5/16"x3/4") A02-02-PS-150-103 4 104 Compression Latch A02-02-PS-150-104 2 105 Countersunk Inner Hex Screw A02-02-PS-150-105 12 106 Knob (5/16"x1/2") A02-02-PS-150-106 1

Phone: (952) 894-6637 Fax: (952) 894-0750 Email: info@ventaire.com 12-MONTH WARRANTY VENTAIRE warrants their products, to the original purchaser, to be free from defects in material and workmanship under normal use and service (except for those cases which buyer supplied materials are used) for a period of 12 months from the original date of shipment. During the warranty period, VENTAIRE, will at its option, repair, replace, or issue credit for any components that are deemed defective by VENTAIRE. Buyer s failure to pay the full amount due within (60) days of invoice shall release seller from any and all liability or obligation to any warranty. Before returning equipment for repair or replacement, a Return Authorization Number must be obtained from VENTAIRE (952-894-6637). The Return Authorization Number must be written on the outside of all shipping cartons. Items returned without a Return Authorization Number will be refused. Items returned should be in original condition in which it was received and must be accompanied with a written explanation of the reason(s) for their return. This warranty does not cover damage caused by accident, misuse, misapplication, or unauthorized service modification.