SCION 436-GC. Dimensions and Weights

Similar documents
Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment

Perkin Elmer Clarus 500 Gas Chromatograph

Gas Chromatography (GC-342)

Nexis GC-2030 Specifications

YL6500 Gas Chromatograph

Agilent 7890A Network Gas Chromatograph

CALIDUS tm the Modular micro Gas Chromatograph

Chemtron Science Laboratories Pvt. Ltd.

TENDER NOTICE NO. 07/2012 INVITATION FOR BIDS / NIT

GC Injectors. GC Injectors

TYPES AND APPROPRIATE INJECTORS

AppNote 6/2008. Automated SPE and Fast GC-ECD Analysis of PCBs in Waste Oil KEYWORDS ABSTRACT INTRODUCTION. MACH, Fast GC-ECD, SPE, PCB, waste oil

HISTORY OF VARIAN CAPILLARY INJECTORS

Thermo Scientific. TRACE GC Ultra. Gas Chromatograph Maintenance and Troubleshooting Manual. PN , Revision March 2011

FIXED GAS ANALYZER (FGA)

Standard Operating Procedure Gas Chromatograph Mass Spectrometry (GC/MS) - Agilent 7890B GC & 240 Ion Trap MS

Selecting the right generator for your GC system. By Ed Connor, GC Product Specialist, Peak Scientific Instruments Ltd

Chemistry Instrumental Analysis Lecture 29. Chem 4631

Technical specifications of FT-IR Spectrometer

THE RIGHT CONSUMABLES FOR YOUR GC APPLICATIONS. Clarus 590/690 Gas Chromatography Consumables and Supplies Reference Guide

Simplicity. Reliability. Performance. Stratum. Automated VOC Sample Prep System

This document is a preview generated by EVS

POPULAR CONFIGURATION GCs Cryosulfur GC. System Overview

Process and Air Monitoring. Online GC systems for continuous monitoring of organic compounds in air and gaseous samples

Key Performance. CompactGC 4.0

22 The Flame Ionization Detector

Purge and Trap Troubleshooting Made Easy?

Process Gas Chromatographs MAXUM edition II

Process gas chromatography

E²M. Innovation with Integrity. Enhanced Environmental Mass Spectrometer. Safety & Security

Aromatics and Oxygenates in Gasoline June2018

1320 Detectors. 1 of 30. Jun Illustrated Parts Breakdown Agilent 6890 Gas Chromatograph Service Manual

Process Gas Chromatograph

SRI 8610C GC for PCB in Transformer Oil Analysis November 2014

Spark Holland introduces

HITACHI CHROMASTER. Clarity Control Module. Code/Rev.: M173/70I Date: 6/23/2018

Thermo Scientific. TRACE GC Ultra. Gas Chromatograph Getting Started. PN , Revision May 2010

MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process

Agilent 1290 Infinity II Vialsampler Data Sheet

To request a quote or locate your nearest dealer, contact Customer Care toll-free in the US at or

Process Gas Chromatograph

I/A Series 716C 1/16 DIN Temperature Controller

Process Gas Chromatograph

Analyze IT. Process Gas Chromatograph. PGC2000 Series

Customised HPLC Systems for Highest Performance

Application Note. The Agilent 1200 Infinity Series Online SPE Solution for the Highest Sensitivity. Author. Abstract.

Automated Solid Phase Extraction (SPE) of EPA Method 1694 for Pharmaceuticals and Personal Care Products in Large Volume Water Samples

DETERMINATION OF PAH In Particulate Matter PM 10 with SPE/EVAporation

Gas Chromatograph. Features. Continuous Analysis of Ultra High Purity Argon to ppb levels.

On-line SPE Enrichment of Trace Organic Contaminants in Water and Juices

High Volume Injection up to 5 ml with the Agilent 1200 Infinity Series Online SPE Solution for Highest Sensitivity

300 series HPLC autosamplers

M700-Series Multifunction OTDR

HPLC Column Ovens and Temperature Controllers

Accurate, cost-saving and reliable Natural gas analyzer SITRANS CV SITRANS CV. Answers for industry.

Chromatography. Research Supplies. 2014/2015 Catalog

Recent Improvements in Process GC Instrumentation

M210 Multifunction Micro OTDR

M210 Multifunction Micro OTDR

BENEFITS. QUATERNARY HPLC SYSTEMS Quaternary and Other Gradients. The Complete Range of HPLC. Convenience of Maintenance. Systems Configuration

Process Gas Chromatograph

Rosemount 1500XA Process Gas Chromatograph

Rosemount 1500XA Process Gas Chromatograph

When reliability is vital. Alemite Carbon Shield TM Systems deliver

Agilent GC Solutions. A Convenient Deans Switch Method for the Analysis of Permanent Gases in Various Matrices by Gas Chromatography CAG

Series 9000 Total Hydrocarbon Analyzer

APPLICATION NOTE DETERMINATION OF THE HYDROCARBON-INDEX DIN EN ISO :2000. APPLICATION NOTE As of July 2017, Version: 1.

SystemsQT for Waters Alliance HPLC Systems (Revision G)

ProStar 325 UV-Vis Detector

IMPROVING THE QUANTITATIVE REPRODUCIBILITY OF AN ATMOSPHERIC PRESSURE CHEMICAL IONISATION SOURCE FOR GC/MS AND GC MS/MS ANALYSIS

MultiPurpose Sampler MPS robotic series

Advanced Autoclave Controller with Recording + 4 Channel Mapping + Pressure Indication with PC Software & Printer Module

ABB MEASUREMENT & ANALYTICS DATA SHEET. C50 1/16 DIN controller / alarm unit

VHP M100 Biodecontamination Systems: Closed Loop

Tubing spares and piping accessories. Gas purification and control 1 Moisture Traps,Carbon traps 2 Gas Purification Panels 3 Gas Control Box

Automação de SPE utilizando sistema robótico Triplus RSH autosampler. Nova Analitica

Complete burner management in a compact, affordable system

HFID Heated Total Hydrocarbon Analyzer Module

Temperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping. Touch Panel PPI

VHP ARD BIODECONTAMINATION SYSTEM

Jetstream Series HPLC - PELTIER COLUMN-THERMOSTATS 1. GENERALITIES

Agilent GC Sampler 80/120 SPME Option

Solution. Supply single or multiple GC instruments Continuous Emission and Air monitoring Mud logging application for oil industry

931D Style B Process Gas Chromatograph

VHP M100 BIODECONTAMINATION SYSTEM

INJECTORS Purge & Trap General Operating Procedures continued

Analysis of Pharmaceuticals and Personal Care Products in Groundwater by Online SPE and LC/MS/MS

Nexera-i Specifications Prominence-i Specifications

WELCOME TO ELLUTIA CHROMATOGRAPHY SOLUTIONS

Rapid Quantification of Polar and Semipolar Pesticide Metabolites with Combined Online SPE and Direct Injection

USER MANUAL USB Multi-Function Datalogger Model RHT35

Enhancing Throughput of Online SPE Analysis of Pesticides in Wastewater The Agilent 1200 Infi nity Series Online SPE Solution

On Line SPE LC/MS/MS Applications

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

ANNEX I. Technical specifications for: Supply of various Trace Explosive Detection Systems

USB Multi Function Dataloggers. RHT30 Humidity/Temperature Datalogger. TH30 Dual Temperature Datalogger

Low Temperature Zirconia Oxygen Analyzer

SPOT HIGH PRECISION PYROMETERS A PRODUCT OF THE SYSTEM 5 FAMILY. 50 to 1800 C / 122 to 3272 F QUALITY CUSTOMER SOLUTIONS

The Viva-ProE System

AS950 REFRIGERATED SAMPLERS

Transcription:

SCION 436-GC Specification Sheet Dimensions and Weights Height*: 57 cm (22.5 in.), Width: 32 cm (13.0 in.), Depth: 61 cm (24.0 in.) Weight*: 26.8 kg (59lb) * Typical values Environmental Conditions Operating temperatures: 10 C to 40 C. Operating humidity (relative): 5 % to 95 % Line voltage requirements: 120 V, 230 V (±10 % nominal) Column Oven Dimensions: 23 cm (w) x 11 cm (d) x 28 cm (h) Temperature range: Ambient: +4 C to 450 C Liquid N 2 : -100 C to 450 C Liquid CO 2 : -60 C to 450 C Temperature program ramps/holds: 24/25 Maximum temperature ramp rate: 170 C/min for all voltages Cool down rate: 400 C to 50 C in 4.5 minutes Temperature set-point resolution: 0.1 C Ambient temperature reject <0.01 C change in oven for 1 C change in ambient temp. Retention Time Repeatability <0.008% or < 0.0008 min, based on n-pentadecane under temperature programming conditions. Area repeatability < 1% RSD Temperature Range ( C) 436-GC Rates ( C/min) 50-70 170 70-115 105 115-175 80 175-300 55 300-450 35 General Specifications Up to 3 EFC modules total, injector, detector and auxiliary Optional backflush GC Control: External events (digital output): 8 standard 8 optional, total 16 Max number of timed events: 30 # Heated zones: Standard 5 Two power outlets 24V (1A max. each) 1

Methods: Maximum stored internal methods: 50 (max. 30 alphanumeric characters) Logging: Run log file (stored with the chromatogram when using CompassCDS) Error log file Local Display: TFT full color screen WVGA resolution (800 x 480); size 23 cm (9 ) Local Control: Touch screen Hard Keys Languages: English, German, French, Spanish, Italian, Portuguese, Cyrillic, Kanji, Chinese (standard and traditional), Thai, Korean and Dutch Local automation: Method lines: 25 Modes: Infinite looping Dual and duplicate injection Communication Ethernet: Protocol: TCP/IP Data rate: 100 Mbps Control: GC control and method parameters Analog output (optional): - Number of channels: 1 - Time programmable steps: 30 Output software selectable (set individual): - 0-1 V (default) - 0-10 V Synchronization signals with other devices and data systems: Ready in and out Start in and out Data Handling and System Control: CompassCDS Chromatography Data System Certifications CSA: C22.2 61010-1 UL 61010-1 IEC: 61010-1 EMC: 47 CFR part 15 ANSI C63.4 EN 61326 ATEX Directive 94/9/EC

Injector Options Maximum injectors: two, operating concurrently Pneumatics: Electronic Flow Control (EFC) Injector types: S/SL Split/Splitless injector* PTV Programmable Temperature Vaporizing* COC Cold On-Column injector* Flash injector PWC Packed/ Wide bore On-Column injector * including septum purge S/SL Split/Splitless Injector Total flow: 500 ml/min for N 2 /Ar 1500 ml/min for He/H 2 Split range: 1-10,000 (column dependent) Wide bore: (0.53 mm) Narrow bore: (0.05 to 0.32 mm COC Cold On-Column Injector Total Flow: 50 ml/min (Type 23 EFC) Temperature range: Ambient +10 C to 450 C using air cooling -60 C to 450 C using liquid CO 2 cooling -160 C to 450 C using liquid N 2 cooling Maximum temperature ramp rate: 200 C/min Temperature ramps/holds: 24/25 Narrow bore PTV Programmable Temperature Vaporizing Injector Total flow: 500 ml/min for N 2 /Ar 1500 ml/min for He/H 2

Temperature range: Ambient + 10 C to 450 C using air cooling -160 C to 450 C using liquid N2 cooling -60 C to 450 C using liquid CO2 cooling Maximum temperature ramp rate: 200 C/min Temperature ramps/holds: 24/25 Split range: 1-10,000 (column dependent) Operational capabilities: Large volume injection Temperature ramped splitless Cold on-column Split and splitless Narrow bore (0.05 to 0.32 mm) Maximum injection volume: 250 µl (LVI mode) Flash Injector Total flow: 50 ml/min (Type 23 EFC) Packed (1/8 to 1/4 ) PWOC Packed/Wide-bore On-Column Injector Total flow: 50 ml/min (Type 23 EFC) Packed (1/8 to 1/4 ) Electronic Flow Control: Injectors (EFC) Module types: 2 injector-specific modules Pressure: 0.1 % Full Scale Resolution pressure set points is 0.001psi Flow sensor accuracy 2% of measured or 0.2% of full scale Flow sensor repeatability 0.5%

Detector Options Maximum detectors: two, operating concurrently (one of which is a Single or Triple Quad MS) Pneumatics: Electronic Flow Control (DEFC) Detector types: FID Flame Ionization Detector TCD Thermal Conductivity Detector ECD Electron Capture Detector NPD NPD Nitrogen-Phosphorus Detector PFPD Pulsed Flame Photometric Detector PDHID Pulsed Discharge Helium Ionization Detector MS Mass Spectrometry (see GC/MS brochure and datasheet) Note: Data Acquisition Rate: 600Hz for all detectors, (exception PFPD) FID Flame Ionization Detector Detectivity: 1.4 pg C/sec Linear dynamic range: 10 7 Flame tip type: ceramic (patented) Operational quality: Flame-out detection Auto re-ignition TCD Thermal Conductivity Detector Detectivity: 300 pg/ml (Butane) Linear dynamic range: 10 6 Operational quality: Filament protection Automatic bridge balancing ECD Electron Capture Detector Detectivity: 7 fg/s Lindane Linear dynamic range: 10 4 Radioactive source: 63Ni - 15 mci (555 Mbq) NPD Nitrogen-Phosphorus Detector Detectivity: N: 100 fg N/sec (Azobenzene) P: 100 fg P/sec (Malathion) Linear dynamic range: N: 10 5 P: 10 4

PFPD Pulsed Flame Photometric Detect Photomultiplier tube: S/P S/P/N Detectivity: S: 1 pg S/sec (S/P tube) P: 100 fg P/sec (S/P tube) N: 20 pg N/sec (S/P/N tube) Linear dynamic range: S: 10 3 P: 10 4 N: 102 Up to 23 elements can be detected PDHID Pulsed Discharge Helium Ionization Detector Detectivity: 50 ppb (Methane) Linear dynamic range: 10 4 (Methane) Operational quality: Gold plated connections Welded column connections Detectors (DEFC) Module types: 6 detector-specific modules Accuracy: ± 7 % set point flow Resolution: 0.1 or 1 ml/min Automation Options 8410 Autoinjector Sample capacity: 10 x 2 ml vials 6 x 5 ml vials 5 x 10 ml vials Large solvent wash vial: 2 x 120 ml* Dual and duplicate mode Internal standard addition Modes of operation: Liquid Ambient headspace* SPME (Solid Phase Micro Extraction)* Sample heating and cooling* Pre-programmed modes of injection Syringes: 1 μl, 2 μl, 5 μl, 10 μl, 100 μl, 250 μl for liquid injection SPME

8400 Autosampler Sample capacity: 100 x 2 ml vials Large solvent wash vial: 2 x 120 ml* Dual and duplicate mode Internal standard addition Modes of operation: Liquid Ambient headspace* SPME* Sample heating and cooling* Pre-programmed modes of injection Syringes: 1μL, 2 μl,5 μl,10 μl,100 μl,250 μl for liquid injection SPME * Optional Optionally a CTC-PAL autosampler, including specific options may be installed.