Specimen delivery date: Test date: Sampling: The test specimen sampled by customer. Order description N o 152/

Similar documents
Determination of airborne sound insulation factor (designation of the test)

Sound absorption coefficient Equivalent sound absorption area Sound absorption coefficient Sound absorption class

Test Report Nº B2016 LACUS IN 24

TEST REPORT No. EN-2160/057/15-098/15

Sound Pressure Level Test Report Report No. : PH2_09_ Date : 2009/6/30

Report Number BTC 15450A

Determination of air borne sound insulation According to ISO 140-3

ISO 7779 INTERNATIONAL STANDARD. Acoustics Measurement of airborne noise emitted by information technology and telecommunications equipment

Consumer vacuum breast-pumps

TNO report MON-RPT-033-DTS

CNBOP-PIB Standard Fire Protection

PCT Workshop Before you leave the office

7.3 Design and Development Design and development planning Design and development inputs Design and development outputs 7.3.

ISO INTERNATIONAL STANDARD

This document is a preview generated by EVS

Technical Note. Noise emission from Dehumidifier Type C65E TC Project no.: I Page 1 of July 2016

Acoustics in open-plan offices A laboratory study

Sound Performance Rating of Non-ducted Indoor Airconditioning

INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD

Procedure for the Approval of New Fire Detection and Alarm Technologies

For Your Security, Safety & Comfort

ISO INTERNATIONAL STANDARD. Acoustics Guidelines for noise control by silencers

Contents EN :2006+A2:2016 (E)

SCOPE OF ACCREDITATION

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE

PQS Independent type-testing protocol

Standard ECMA th Edition - December Declared Noise Emission Values of Information Technology and Telecommunications Equipment

European Technical Assessment ETA 17/1007 of 02/05/2018

INTERNATIONAL STANDARD

Handbook Qualification Quiet Room label

Sound Performance Rating of Outdoor Unitary Equipment

E/ECE/324/Rev.1/Add.27/Amend.5 E/ECE/TRANS/505/Rev.1/Add.27/Amend.5

Technical Note. Noise emission from Dehumidifier Type C35E-3.3 and Type C35E-5.6. TC Project no.: T Page 1 of 10.

ISO INTERNATIONAL STANDARD. Determination of the resistance to jet fires of passive fire protection materials Part 1: General requirements

INTERNATIONAL STANDARD

Technical Note. Noise emission from Dehumidifier Type C22/CR100. TC Project no.: T Page 1 of January 2016

TEST REPORT No /9943/CPR

PQS Independent type-testing protocol

Electromagnetic Locking Devices Performance Requirements

Classification Report Reaction to fire of building elements DIN EN :2007. Class E

ISO INTERNATIONAL STANDARD. Small craft Airborne sound emitted by powered recreational craft Part 1: Pass-by measurement procedures

IECRE OPERATIONAL DOCUMENT

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD

ISO 6393 INTERNATIONAL STANDARD. Earth-moving machinery Determination of sound power level Stationary test conditions

This document is a preview generated by EVS

Analysis Report

Contact person Date Reference Page Christian Larsson P01958A 1 (3) Safety

Pressure Equipment Directive PED 2014/68/EU Commission's Working Group "Pressure"

Acoustical Test Methods and Sound Power Rating Procedures for Transport Refrigeration Equipment

Type: Play house Length: 1195 mm Width: 1195 mm Height: 1740 mm Materials: 18,7 mm laminated wood

ISO 6396 INTERNATIONAL STANDARD. Earth-moving machinery Determination of emission sound pressure level at operator's position Dynamic test conditions

1 Introduction - The rating level. 3 Subjective or objective analysis? 2 Determination of the adjustment for annoying tones

Verification & Testing for Conformity Assessment / EC Verification. NB-Rail (ERTMS Group)

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

TEST REPORT No

Loudspeaker Test. Report

ISO INTERNATIONAL STANDARD

DUST TEST REPORT. :Gold Apollo Co., Ltd. Company Model Name :A27. Date of Received :APR. 19, 2006 Date of Tested :APR. 19, 2006

INTERNATIONAL STANDARD

Annex of the certificate (Page 1/7) Accreditation Scope

Test Report. Appliance EMF Testing

PERFORMANCE & TESTING

BRL-K774/ Evaluation guideline. for the Kiwa product certificate for Compression fittings to tighten with matching clamping device

GUARDIAN FIRE TESTING LABORATORIES, INC.

Joint Stock Company Alzida Savanorių pr. 221, LT Vilnius, Lithuania

CAN/ULC-S102 Surface Burning Characteristics of "8 mm Fire Rated High Pressure Laminate Phenolic Panel"

ISO INTERNATIONAL STANDARD. Acoustics Measurement of sound pressure level from service equipment in buildings Engineering method

DEPARTMENT OF TRADE AND INDUSTRY DEPARTEMENT VAN HANDEL EN NYWERHEID. NATIONAL REGULATOR FOR COMPULSORY SPECIFICATIONS ACT (Act 5 of 2008)

Test Report to AS/NZS :2015. Report No. T160402_S

ISO INTERNATIONAL STANDARD

Gas meters - Conversion devices - Part 1: Volume conversion

National technical assessment NTĮ :2013

IEC PROJETOS EM VOTAÇÃO

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

INTERNATIONAL STANDARD

SOUTH AFRICAN NATIONAL STANDARD

This annex is valid from: to Replaces annex dated: Locations where activities are performed under accreditation

CAN/ULC-S102 Surface Burning Characteristics of "ezobord 9 mm (Green)"

ASTM E 662 Rate of Smoke Generation of "Moniflex as manufactured by Isoflex AB"

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Supertron Sensing Pte Ltd Certificate No. : LA C Blk 16 Kallang Place #07-04 Issue No. : 4 Singapore Date : 04 February 2015

RSE Kazakhstan Institute of Metrology

Construction Products Directive

Huminator II. Precision Humidity Generator. ww.testo.in

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

TABLE OF CONTENTS. 1.0 INTRODUCTION Scope References Test Specimen Description Summary 1

technical data air conditioning systems FDKS-CVMB Concealed ceiling, Inverter Controlled Unit Split Sky Air

Proforma for Surveillance of Recognized Environmental Laboratory under the Environment (Protection) Act, 1986

RENAR Accreditation Activities

ASSOCIATION POUR LA CERTIFICATION DES MATERIAUX ISOLANTS

Test Report for the determination of Critical Fall Height for Under Playground Surfacing with Plants

Australian Standard. Electroacoustics Sound calibrators AS IEC This is a free 7 page sample. Access the full version online.

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Contact person Date Reference Page Henrik Andersson F (4) Electronics

Power Amplifiers. Equalizers

CERTIFICATE of Product Conformity (QAL1)

Transcription:

CONSTRUCTION OF KAUNAS UNIVERSITY OF TECHNOLOGY SCIENCE LABORATORY OF BUILDING THERMAL PHYSICS BANDYMAI ISO/IEC 17025 Nr. LA. 01.031 Date: 19 of November 2013 Page (pages) 1 (5) Test method: Specimen description: Determination of the airborne sound reduction index (test name) LST EN ISO 10140-2:2010 Acoustics Laboratory measurement of sound insulation of building elements. Part 2: Measurements of airborne sound insulation (ISO 10140-2:2010); LST EN ISO 10140-1:2010 Part 1: Application rules for specific products (ISO 10140-1:2010); LST EN ISO 10140-4:2010 Part 4: Measurement procedures and requirements (ISO 10140-4:2010); LST EN ISO 10140-5:2010 Part 5: Requirements for test facilities and equipment (ISO 10140-5:2010). (number of normative document or test method, description of test procedure, test uncertainty) Soundproof door. Dimensions width 890 mm, height 2050 mm. Profiles: frame (laminated pine) 92 42 mm; leaf 62 mm thickness: external and internal door leaf from MDF (6 mm) and particle board (10 mm); heat insulation (mineral wool Paroc 30 mm). Sealing: Silicon seal T104/8, Fire seal 2x20 (TP2102020N). Hinges: ABLOY NTR 110-30TSS ZN, Abloy NTR 110-30TSS (PKU, PKE, CR). Lock: ASSA 565. (identification of the specimen) Customer: Põltsamaa Uksetehas OÜ, Riia 136a, EE-51014 Tartu, Estonia Manufacturer: Põltsamaa Uksetehas OÜ, Riia 136a, EE-51014 Tartu, Estonia Test result: Name of quantity, unit Test method Test result Weighted sound reduction index R w (C; C tr ; C 100-5000 ; C tr,100-5000 ), db LST EN ISO 717-1:2013* 36 (0;-2; 0;-2;) db Note. The testing are carried out in purpose for conformity assessment of the product according to LST EN 14351-:2006+A1:2010 *Flexible scope of accreditation Test place: Science Laboratory of Building Thermal Physics, Institute of Architecture and Construction of Kaunas University of Technology (name of the test laboratory) Specimen delivery date: 2013-11-19 Test date: 2013-11-19 Sampling: The test specimen sampled by customer. Order description N o 152/13 2013-10-29 Additional information: Annex: Application 2013-10-31, drawing (any deviations, complementary tests, exceptions and any information related with particular test) 1 - Measurement results, 2 - Schematic view of the test, 3 - Cross section of the specimen (the numbers of the annexes should be pointed out) Technical manager: J. Ramanauskas (approves the test results) (signature) (n., surname) Tested by: V. Dikavičius (technically responsible for testing) (signature) (n., surname) S. P.

2 (5) Installation of the sample and measurement Sample has been installed into the hole (2100 910 mm) of the dividing wall between two reverberating chambers by workers of the laboratory. The installation of the specimen is described on the drawing in Annex 2. The airborne sound reduction index has been determinate by using the precision integrated noise spectra meter, positional microphone and loudspeaker. Methods and equipment The airborne sound reduction index R was determinated in accordance with requirements of LST EN ISO 10140-1:2010 [1], LST EN ISO 10140-2:2010 [2], LST EN ISO 10140-4:2010 [3], LST EN ISO 10140-5:2010, [4]. Weighted sound reduction index R w was determinated in accordance with requirements LST EN ISO 717-1:2013 [5]. The thickness of the reverberating chamber s walls is 0,25m. The thickness of the covering masonry shell is 0,38m. The dimensions of the floor of sound chamber are 4,9x4,8m, height 3,5 3,0m (the coming down by steps ceiling). The dimensions of the floor of the sound receiving chamber are 4,8x4,3m, height 3,5 3,0m (the coming down by steps ceiling). The chamber s volumes are 80 and 68,56m 3. Equipment of the measurement: Microphone L&D (Larson & Davis) 2560 Nr.2572; Initial microphone amplifier L&D, PRM 900C Nr.3782; Precision integrated noise spectra meter and noise generator L&D, 2800 B Nr.0527; Microphone LD Nr.2546, Initial microphone amplifier PRM900C Nr.3777 calibration certificate VMC Nr.794567 AV 3.3-00-807, 2011-03-07; Calibrator of sound level LD CAL200 Nr.0712 calibration certificate VMC Nr.794566 AV 3.3-00-806, 2011-03-07 Loudspeaker Power amplifier Microphone positioning system Relative humidity and temperature sensor Testo 615, No. 3070000244Gb Static pressure Barometer Aneroider No. 1685 Sources: [1] LST EN ISO 10140-1:2010 Acoustics. Measurement of sound insulation in buildings and of building elements. Part 1: Application rules for specific products (ISO 10140-1:2010). [2] LST EN ISO 10140-2:2010 Acoustics. Measurement of sound insulation in buildings and of building elements. Part 2: Measurement of airborne sound insulation (ISO 10140-2:2010). [3] LST EN ISO 10140-4:2010 Acoustics. Measurement of sound insulation in buildings and of building elements. Part 4: Measurement procedures and requirements (ISO 10140-4:2010). [4] LST EN ISO 10140-5:2010 Acoustics. Measurement of sound insulation in buildings and of building elements. Part 5: Requirements for test facilities and equipment (ISO 10140-5:2010). [5] LST EN ISO 717-1:2013 Acoustics- Rating of sound insulation in buildings and of building elements. Part 1. Airborne sound insulation (ISO 717-1:2013). [6] LST EN 14351-1:2006+A1:2010 Windows and doors Product standard, performance characteristics Distribution: Customer Original ASI, SŠFM laboratory Original Contact person: Vidmantas Dikavičius, tel. +370 37 350799

63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000 The airborne sound reduction index R,dB INSTITUTE OF ARCHITECTURE INSTITUTE OF AND CONSTRUCTION OF KAUNAS ARCHITECTURE UNIVERSITY AND OF TECHNOLOGY SCIENCE LABORATORY OF BUILDING Notified THERMAL Body number: PHYSICS 2018 Annex 1 - Measurement results Science Notified laboratory Body number: of building 2018 TEST REPORT No. 152 SŠF/13 A en Date: 19 of November 2013 Sound reduction index, R, in accordance with ISO 10140-2 (test name) Test method: LST EN ISO 10140-1:2010, LST EN ISO 10140-2:2010, LST EN ISO 10140-4:2010, LST EN ISO 10140-5:2010 (number of normative document or test method, description of test procedure, test uncertainty) Manufacturer: Client: Põltsamaa Uksetehas OÜ, Riia 136a, EE-51014 Tartu, Estonia Põltsamaa Uksetehas OÜ, Riia 136a, EE-51014 Tartu, Estonia Product identification: Soundproof door (identification of the product) Test element mounted by: Laboratory person Description of test facility, test element and test arrangement, including reference to ISO 10140-2:2010, where applicable: Test room identification: horizontal Relative humidity in the test rooms: 50,0 % 3 (5) Area, S, of the test element: 1,91 m 2 Static pressure: 0,101 MPa Air temperature in the test rooms: 18,0 o C Receiving room volume: 68,56 m 3 Test date: 2013-11-19 Name of test institute: Frequency R, db f, Hz 1/3 octave 50 63 80 100 27,3 125 31,7 160 34,2 200 33,1 250 34,5 315 37,0 400 35,0 500 31,6 630 31,6 800 32,8 1000 34,1 1250 35,7 1600 37,1 2000 39,2 2500 41,5 3150 42,7 4000 5000 39,8 41,4 Science Laboratory of Building Thermal Physics, Institute of Architecture and Construction of Kaunas University of Technology 60 50 40 30 20 10 0 Frequency f, Hz BANDYMAI ISO/IEC 17025 Nr. LA. 01.031 Rating in accordance with LST EN ISO 717-1:2013 R w (C; C tr ) = 36 (0; -2) db; C 50-3150 = db; C tr, 50-5000 = db; C 100-5000 = 0 db; C tr,100-5000 = -2 db Tested by: V. Dikavičius (technically responsible for testing) (n., surname) (signature)

2 Annex. Schematic view of the test 4 (5) Reverberating chambers Specimen bandinys Sound Priimamo receiving garso chamber kamera pozicionuojamas Microphone mikrofonas Sound Siunčiamo source garso chamber kamera Vertical section vertikalus pjūvis užblokuota anga durims Hole įstatyti Horizontal horizontalus section pjūvis

3 Annex. Cross section of the specimen 5 (5) Fig 1. Cross section of door (information submitted to the customer)