Operation and Maintenance Instructions

Similar documents
Technology for life. Unit heater LH

WOLF VENTILATION SYSTEM PRICE LIST

Fan coil unit KL. Wall unit Ceiling unit

Technical documentation Fan coil unit

CASSETTE UNIT. Comfort Circle

Operating instructions

Energy-efficient heat source provides comfort in large rooms

TopVent Design Handbook

Supply air unit VEKA Installation & Maintenance

VMA-VMB NOVA AIR HEATERS. NoVa air heaters

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Fresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit.

The green and friendly entrance. Comfort air curtains Model CA 2

Installation and operating instructions. DK energy storage and DK energy buffer

TERM-E ELECTRIC HEATING AND VENTILATION UNITS

CIRCO 6 Solar Circulation Unit

Operating instructions

RL/1 SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL RL 34/1 MZ kw

Operating Manual MS220KA and MSR220KA

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

Installation Instructions

Installation and maintenance manual

VIESMANN. Installation instructions VITOCELL 300-B. for contractors. Vitocell 300-B Type EVBA-A. Dual mode DHW cylinder, 300 and 500 l

Description. Construction

KUH. Horizontal Unit Heater. Applications. Description

Operating Instructions

WOLF GAS CONDENSING BOILERS COMFORTLINE

Operating instructions Oil condensing boiler

Installation and Maintenance Novax Smoke Exhaust Fan Type ACN Smoke

Mounting and operating instructions KEMPER KTS temperature-controlled 3-directional reversing valve Figure DN 32 DN 80

Original operating instructions Safety switch with guard locking AC901S AC902S

Temperature Sensor TRG Original Installation Instructions English

VIESMANN. Installation instructions VITODENS 200-W. for contractors

51AKS I S O OWNER S MANUAL

Optimal work climate with open doors. Industrial air curtains Model IndAC

Main technical datas:

EQGA AND EQGB HYGIENIC VERSION, CODE SUFFIX I = 3 AND 4

51AKB / 51 AKC OWNER S MANUAL

Installation and maintenance instructions

IPVB EC inline power venter

FSW300 Series Flow Switch

Installation, operating and servicing instructions

ACN SMOKE INSTALLATION AND MAINTENANCE

ELECTRIC UNIT HEATER REGULAR DUTY

Grohtherm Wireless! Installation Instructions Pumped High Pressure

Grohtherm Wireless! Installation Instructions Pumped

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

Product range Code HE1 Connection and energy management compact unit without anti-condensation valve

Model: 1100 Float-Controlled Condensate Trap, PN 25

VIESMANN. Service instructions VITOCELL 300-B VITOCELL 300-V. for contractors

Model: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN 40

Jet Fan Types AUC/ARC/AUR/ARR/AUO/ARO Installation and Maintenance

WOLF WARM AIR CURTAIN

Operating Guide. Termix Compact 28 VX-FI / HWP / HWS. 1.0 Table of Contents. 1.0 Table of Contents

LS Condensate Removal Pump INSTRUCTION MANUAL REVISION A

ValkyrieTM. Instruction Manual. Includes our new CoolTouch TM 6 Speed DC Control System Looks permanent, but goes wherever you go! U.S.

INDUSTRIAL AIR CURTAIN. IndAC 2

238 Series. Industrial/Commercial Electric Unit Heater. Owner s Manual

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A

The new equipment generation: Install, connect and save energy! KG-Kompakt Air handling unit with heat recovery

FerronTM. Instruction Manual A Kichler Decor ceiling fan

Montageanleitung RLO (Original) Mounting Instructions RLO (Translation of the original)

Air handling unit KG Standard (Translation of the original)

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2018

Installation and maintenance instructions

Installation Instructions

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

DLKF. EBARA Submersible Sewage Pumps Specifications Project: Model: Chk d: Date:

BKA-EN Fire Damper. Additional operating instructions according to

Mechanical seals external, single or double, to DIN EN 12756

LUH HORIZONTAL FAN-FORCED UNIT HEATER

VERSO Air Handling Units

THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM

60" Hatteras BayTM. Patio. Instruction Manual. Includes our new Wall Control System. A Kichler Décor ceiling fan

MultiMAXX HN OPERATION MANUAL

Sunburst. Instruction Manual. Includes our new Wall Control System. A Kichler Décor ceiling fan

Indholdsfortegnelse. Danvent Air Handling Units SERVICE MANUAL

1592P01. for liquids in piping DN

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

Decentralised ventilation units

GLEB Kitchen exhaust fan

Duct Heaters volts/1 phase volts/3 phase volts/3 phases volts/3 phases. Flange Type Duct Heater.

VIESMANN. Installation instructions VITOCELL 300-V/W. for contractors. Vitocell 300-V/W Type EVIA-A

Avensys Avensys FIN EST SLO RUS UAE

VEX100 series Air handling units with cross-flow heat exchanger

Installation Instructions

1592P01. for liquids in piping DN max. DC 48 V, 1 A, 20 W

Centrifugal air heaters hot water or electrical supply

KITCHEN EXHAUST FAN GLEC-6 INSTALLATION AND MAINTENANCE

Cooling and heating systems. Static cooling ceiling system SKS-5/3 for visible installation

FUN I / FUN U FUN I MCP / FUN U MCP FUN V / FUN V MCP

SECTION (15833) - HVAC POWER VENTILATORS

VIESMANN. Installation instructions VITOCROSSAL 200. for contractors. Vitocrossal 200 Type CM2 Gas fired condensing boiler with MatriX radiant burner

BSK-RPR Fire Damper. Additional operating instructions according to

Orrin. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

Installation Instructions

Thermal Devices, Inc. Mount Airy, Maryland USA

RVA /109. Heating Circuit ZONE Controller. Instructions for the INSTALLER

CENTRIFUGAL FAN IN SCROLL CASING. Helix S-Vent OPERATION MANUAL

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

Transcription:

Operation and Maintenance Instructions Unit Heaters LH (Translation of the original) Wolf GmbH Postfach 1380 84048 Mainburg Tél. 08751/74-0 Fax 08751/741600 Internet : www.wolf-heiztechnik.de N d art. : 3040531_201211 Subject to modifications GB

Index Index General... 3 Symbols... 3 Safety instructions... 4 Standards and regulations... 4 Unit description... 4 Installation and operation instructions... 5 Prior to the installation... 6-7 Installation instructions... 8-10 Electrical connection...11 Switches... 12-14 Control devices for damper actuators... 15 Thermostats... 16 Control system WRS... 17-20 Actuators... 21 Push-button... 21 Intermediate terminal box... 22 Maintenance... 23 Frost protection... 23 Hydraulic adaption of unit heaters within a group... 24 Rain protection hood and roof lead-in box... 25-26 Notes... 27 2 3040531_201211

General / Symbols General The present operation and maintenance instructions are exclusively applicable for Wolf unit heaters LH. Read these instructions carefully prior to the installation. These instructions, as a part of the unit, have to be kept accessible. No warranty claims will be accepted if operation and maintenance instructions are not adhered to. Symbols The following symbols are used in these instructions. These important instructions concern personal safety, as well as technical reliability. "Safety instructions" are instructions with which you must comply exactly, to prevent injury and material losses. Danger through "live" electrical components. Never touch electrical components or contacts when the ON/OFF switch is in the ON position. This creates a risk of electrocution, which may cause injury or death. Attention : "Attention" indicates technical instructions which you must observe, to prevent material losses and unit malfunctions. In addition to the operation and maintenance instructions there are as well stick-on labels on the unit, which have to be adhered to in the same manner. 3040531_201211 3

Safety Instructions / Standards, Regulations / Unit Description Safety instructions Installation, commissioning, service and operation may only be carried out by qualified personnel. For electrical installations VDE regulations and local guidelines have to be adhered to. The unit may only be operated within the capacity range indicated in the technical documents of Messrs. Wolf. The unit may only be applied for purposes of ventilation. It is ony suitable for air. The air must not contain any hazardous, combustible, explosive, aggressive, corrosion developing or any other dangerous substances. The unit may only be operated in technically perfect condition. Any malfunction or damage which may influence the safety or perfect function of the unit have to be eliminated by a recognized specialist, at once. Damaged unit components may only be replaced by original Wolf - spare parts. Only qualified electricians are allowed to perform work on electrical appliances or components, adhering to the electric regulations. It is not allowed to work in the direct vicinity of a running fan. There is a risk of being hurt by the running fan. Before undertaking maintenance work, always ensure that the system main isolator / the repair switch(es) are OFF and locked to prevent unintentional reactivation. Standards, Regulations The following standards and regulations apply to the LH unit heaters: - Machine directive 2006/42/EU - Low voltage directive 2006/95/EU - EMC directive 2004/108/EU - DIN EN 12100 Safety of machines; general design principles - DIN EN 13857 Safety of machines; safety distances - DIN EN 349 Safety of machines; minimum distances - DIN EN 953 Safety of machines; guards - DIN EN 60204-1 Safety of machines; electric equipment For the installation and maintenance, the following regulations and safety instructions have to be adhered to: - DIN VDE 0100 Requirements for high voltage installations up to 1000 V - DIN VDE 0105 Operation of high voltage installations, general restrictions - DIN VDE 0701-0702 Repair, modification and testing of electrical appliances General unit description and design Wolf unit heaters consist of a zinc plated sheet steel casing. The casing is composed of a self-supporting pentapost profile construction, which is welded and zinc plated, and of zinc plated lateral casing panels. The casing is provided with a LPHW-heating coil which consists either of copper tubes and aluminium fins or galvanized, finned steel tubes. The air inlet is provided with a unit consisting of an axial fan-motor-protection grille assembly which takes the air in via the air inlet in the rear panel. While passing the heat exchanger on the discharge side the air is heated. The warm airstream may be turned downwards via an adjustable discharge louvre. 4 3040531_201211

Installation and Operation Instructions Heat exchanger When connecting the heat exchanger counterhold with pipe-wrench. The flow of the heating system has to be connected on the air discharge side of the heat exchanger. For steam: Steam connection on top Condensate return on bottom of discharge side Connections on left hand side only, in direction of air flow Attention : Evacuation of air and fluid has to be provided on site! Operation limits for LPHW/MPHW: Heat exchanger Co./Al., type 1, 2, 3, 4, NP 16, up to 140 C (threaded sleeves) Heat exchanger steel-galvanized, NP 10, up to 140 C (threaded sleeves) Heat exchanger steel-galvanized, NP 10, up to 180 C (welded flanges) Operation limits for steam: Heat exchanger Co./Al., type D, up to 9 bar saturated steam Heat exchanger Co./Al., upt to 9 bar saturated steam Electric heater To avoid overheating, pay atenteion to the following minimum air volumes: Attention : LH 25 40 63 100 Luftrichtung horizontal V min [m³/h] 800 1600 2500 4000 Luftrichtung vertikal V min [m³/h] 1000 2200 3200 5000 Protective measures: In any case it has to be secured that the electric heater is switched off when the air volume is falling below the indicated minimum. Additionally, the electric heater may only be set into oberation by one or several magnetic swiches whose control circuit leads over the automatic overheating controllers wired in line. Pay attention to the fact that at least one automatic controller has to be mounted on top of the electric heater. In any case, protect against water Ceiling-mounted unit (1) (2) Attention : In ceiling-mounted units there may occur damages by overheating when motor is swiched off. For this reason the water inlet temperature has to be limited on: Motor for higher surrounding temp. (on request) 115 C when additional sections are 140 C when additional sections are mounted (1) mounted (2) 140 C without additional selections (2) 180 C without additional sections (2) When fan stops all control valves have to be closed automatically. Motors Attention : LH-three-phase motors (except explosion proof motors) may either operate on low spped Y or on high speed. The motor windings are designed accordingly. Motors for single-phase alternating current may only oberate on high or low speed depending on delivery. LH-single-phase and three-phase motors (except explosion proof motors) are protected with thermal cutours, which interrupt the control circuit of switch or step switch in case of overheating of the fan motor. When temperature decreases, the motor switches on automatically. The winding protection wirks only in case of switching the therminal cutouts to the control circuit of a switch of step switch. Using switches or speed controllers not delivered by Wolf, we can t take any warranty! 3040531_201211 5

Prior to the Installation Clearances Clearances for LH ceiling unit or wall unit in metres Secondary vortex Secondary vortex LH LH to LH LH to wall 25 7-9 3-4 40 9-11 3-5 Air throw Primary air Primary air Primary air 63 11-13 4-6 100 13-15 5-7 Spacing Spacing Spacing 7-15m 7-15m 3-7m larger throw by approx. 25% Larger throw for very high rooms by means of discharge cone up to 2,5 m max. Four-side discharge for lower rooms Discharge accessories referring to a.m. spacing, a t air (= t discharge - t room) of approx. 25K and high speed. LH 25 40 63 100 Spacing: Discharge/Floor up to 2,5 m 4-side-discharge 4-side-discharge 4-side-discharge 4-side-discharge 3-4 m Wide spread discharge Wide spread discharge Wide spread discharge Wide spread discharge 4-5 m Cone Cone Louvre Wide spread 5-6 m Cone Cone Cone Louvre à partir de 6 m Cone Cone Cone Cone If the temperature difference t air exceeds 30K the above selection table is no longer applicable, because of the reduced penetration. 6 3040531_201211

Prior to the Installation Clearances LH 25 40 63 100 Clearances for wall-mounted units and clearances for ceiling-mounted units, vanes vertical. Ceiling-mounted unit, vanes deflected. LH from LH LH to wall LH from LH LH to wall 7-9m 3-4m - 12m 4-6m 9-11m 3-5m - 14m 5-7m 11-13m 4-6m - 16m 6-8m 13-15m 5-7m - 18m 7-9m Air throw: wall-mounted unit LH 25 40 63 100 Type 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 Air throw m Air throw [m]* high speed 19 18 16 15 27 26 23 21 29 27 25 23 36 35 34 32 low speed 16 15 13 12 20 19 16 14 22 20 18 17 30 28 26 25 0,2 m/sec. Height above floor min. 2,5m max. 4,0m Angle of adjustment Speed of air stream in utility area 0,2m/sec. * Figures represent air throws on defined operating conditions. (mixing temperature 10 K above room temperature) Height above floor, ceiling-mounted unit LH 25 40 63 100 Type 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 Height above floor [m]* 5 4,5 4 3,5 6 5,5 5 4,5 7 6,5 6 5,5 8 7,5 7 6,5 Height above floor [m] Angle of adjustment Speed of air stream in utility area 0,2m/sec. *The optimum vane angle depends on the height above floor. Higher above floor heights on request. Height wall-mounted unit with adaption cone and induction louvre A B C D E F LH 63 1040 120 270 300 350 460 LH 100 1130 120 320 340 350 590 A C D E LH 63 100 Type 1 2 1 2 Max. height (m) 12 11 11 10 Higher above floor heights on request. F B 3040531_201211 7

Installation Instructions Suspension angles 9 Attach the suspension angles to LH-unit. For mounting on the ceiling with horizontal air outlet, first fix screws Ø 8 mm (on site) to the ceiling. Hang up LH-unit at key holes and tighten screws. 240 5 120 65 For sloping the LH-unit from the ceiling, insert threaded shaft (8 mm) from side through slot of key holes and tighten by nut, counter-nut and 2 washers. Depending on the construction of the ceiling, use appropriate screws and dowel pins, if necessary. Threaded sheft 9 25 L max Suspension Fix screws Ø 8 mm to wall. Hang up LH-unit and suction accessory by means of key-holes and tighten screws. For wall- mounted units exceeding a max. length Lmax. provide an additional support or suspension on-site. LH 100 with steel-galvanized heat exchangers type 2 and 3 require this additional support or suspension already at a unit-length of L = Lmax. LH 25 40 63 100 L max. [mm] 1100 1100 1100 1220 Bracket Support Mounting brackets Fit mounting brackets to LH-unit by means of enclosed screws. Attach screws to wall of ceiling according to measure "c". Hang up LH-unit by means of key holes of mounting brackets and tighten screws. a d c e x x b x x g f h x x l LH a b c d e f g h i 25 480 250 380 70 30 170 155 155 434 40 480 250 2 x 170 90 50 2 x 170 70 70 564 63 784 350 170+340+170 72 32 3 x 170 137 137 734 100 784 350 170+340+170 72 32 3 x 170 137 137 894 Dimensions en [mm] 8 3040531_201211

Installation Instructions Prior to the application of fastening sets the static conditions of the concrete or steel bars have to be checked and taken into account. Assembly exclusively with basic units at a total depth of 300 mm. Fastening kit for concrete bar vertical - Fasten fixing rail with dowels and screws, provided on site, to the concrete bar. - Fit fastening brackets to the unit with enclosed screws. - Fit suspending rails to the fastening brackets with enclosed screws, washers and nuts. - Hang total assembly (unit fastening brackets and suspending rails) into fixing rail. To prevent the unit from dropping before fitting the pipework, the inferior suspending rail may be secured additionally by fitting it to the concrete bar with screws and dowels. Suspending rail Fastening bracket Fixing rail Suspending rail Fastening brackets LH-Unit Fastening kit for steel bar vertical Suitable for all types af steel bars at a flange width "b" of min. 100 mm up to max. 300 mm, and a flange thickness "t" of min. 6 mm up to max. 21 mm. - Fit fixing rail to steel bar with enclosed clamping jaws. - Fit fastening brackets to the unit with enclosed screws. - Fit suspending rails to the fastening brackets with enclosed screws, washers and nuts. - Hang total assembly (unit, fastening brackets and suspending rails) into fixing rail. - Fit inferior suspending rail to steel bar with clamping jaws. Clamping jaws Suspending rail Fastening bracket Suspending rail Fixing rail b Fastening bracket t 3040531_201211 9

Installation Instructions Fastening kit for steel bar inclined with inclination equalization Suitable for all types of steel bars at a flange width "b" of min. 100 mm up to max. 300 mm and a flange thickness "t" of min. 6 mm up to max. 21 mm. - Fit fastening brackets to the unit with enclosed screws. - Fit angle steel profiles of inclination equalization with their short end to the suspending rails, by using the enclosed screws and nuts. - Connect angle steel profiles at their long ends and keep them movable. - Fit suspending rails to the steel bar with enclosed clamping jaws. - Fit unit to inclination equalization assembly via its fastening brackets by means of threaded rods M8 (on site). Clamping jaws b Suspending rail t Threaded rods M8 (on site) Fastening brackets LH-Unit Inclination equalization Fastening kit for steel bar horizontal and inclined without inclination equalization Suitable for all types of steel bars at a flange width "b" of min. 100 mm up to max. 300 mm and a flange thickness "t" of min. 6 mm up to max. 21 mm. - Fit fastening brackets to the unit with enclosed screws. - Fig. 1 and 2: - Fit suspending rails to the fastening brackets with enclosed screws, washers and nuts. - Fit suspending rails to the steel bar with enclosed clamping jaws, as shown in fig. 1 and 2. - Fig. 3: - Fit suspending rails to the steel bar with enclosed clamping jaws. - Fit unit to suspending rails via its fastening brackets by means of threaded rods M8 * (on site). t b b t b t * Fig. 1 Fig. 2 Fig. 3 10 3040531_201211

Electrical Connection Three-phase-motors Low speed High speed U1 W2 11 U1 W2 11 V1 U2 V1 U2 W1 V2 12 W1 V2 12 L1 L2 L3 TK TK L1 L2 L3 TK TK Operation of several LH-units with one switch or control device LH-units of different sizes and capacity can be oberated with one switch up to the max. permissible capacity or max. permissible current of the switch. When operating several LH-units, the motor terminals have to be switched parallel, the thermal cutouts and anti-frost thermostats in line! Terminal clamp 5 on site. LH-unit with termal cutouts and anti-frost thermostat U1 V1 W1 W2 U2 V2 12 11 1 2 4 U1 V1 W1 W2 U2 V2 12 11 5 1 2 4 U1 V1 W1 W2 U2 V2 12 11 5 1 2 4 LH-unit with thermal cutouts U1 V1 W1 W2 U2 V2 12 11 U1 V1 W1 W2 U2 V2 12 11 5 U1 V1 W1 W2 U2 V2 12 11 5 U1 V1 W1 W2 U2 V2 TK TK R1 R2 5 LH-step-switch or control device (i.e. step-switch DS) U1 V1 W1 W2 U2 V2 TK TK R1 R2 5 LH-step-switch or conrol device (i.e. step-switch DS) Single-phase-AC-motors 230 V / 50 Hz Single-phase-AC-motors are delivered only in high-speed-wiring. 11 Z1 12 11 Z1 12 Wire thermal cutouts in line with motor winding. U1 Z2 U2 U1 Z2 U2 Speed control with 5-step-switch type E5... N L1 R1 R2 N VM 5-step-switch E5-3 L1 11 N 12 Terminal box at mixing box N L1 R1 R2 N VM 5-step-switch E5-3 3040531_201211 11

Switches Single-step switch D1 for single-speed operation of one or several unit heaters. Operation voltage Control voltage 400 V 230 V Room thermostat J U1 V1 W1 W2 U2 V2 11 12 Max. capacity 3 kw Weight 0,9 kg Prot. class IP 54 Part no. 79 40 001 S1 F1 3,15A 2 1 U1 V1 W1 4 L1 L2 L3 3 R2 N K1 Automatic start-up when winding temperature drops (motor). 1) TK / 11-12 * Link acc. to motor type-plate ** Link is not applicable with room thermostat K!: 3 / 4 contact for heating requirements L1 L2 L3 N Two-step switch DS for two-speed operation of one or several unit heaters. Operation voltage 400 V Control voltage 230 V Max. capacity 4 kw Weight 0,9 kg Prot. class IP 54 Part no. 79 25 110 U1 V1 W1 1 W2 U2 V2 11 12 U1 V1 W1 W2 U2 V2 TK TK R1 R2 5 5 7 14 F1 3,15A S1 Automatic start-up when winding temperature drops (motor). 2 4 610 8 12 13 U1 V1 W1 4 L1 L2 L3 3 0 1 R2 K1 N 2 L1 L2 L3 N 1) TK / 11-12 * When connecting a room thermostat remove link K!: 3 / 4 contact for heating requirements Attention : Without switches for complete protection we do not give motor warranty! When the winding temperature is being exceeded without a complete motor protection switch, the motor can get badly damaged. Complete motor protection switches for 3 x 230 V available on request. 12 3040531_201211

Switches Five-step switch D 5-... for five-speed operation of one or several unit heaters with complete motor protection with reclosure preventing device. Fan motor with thermal cutout Link acc. to motor type-plate Type D5-1 D5-3 D5-7 D5-12 D5-19 Operation V 400 400 400 400 400 voltage Control voltage V 230 230 230 230 230 Max. current A 1 2 4 7 12 Weight kg 4,5 7,0 9,0 19,0 27,0 Prot. class IP 40 20 20 20 20 Width A 150 230 230 230 310 Height B 200 310 310 310 385 Length C 175 185 185 185 225 Part number 2740015 2740010 2740013 2740014 2740017 Locking switch-off at winding overtemperature (motor). Reclosing: switch position 0, then select requiered stage. Contact for heating requirements. * When connecting a room thermostat remove link H1 = Sevice H2 = Interruption Five-step switch E 5-3 for five-speed operation of one or several unit heaters with single-phase-ac-motors with complete motor protection. Fan motor with thermal cutout Operation voltage 230 V Max. current 3 A Weight 4,0 kg Prot. class IP 40 Part no. 27 40 006 Automatic start-up when winding temperature drops (motor). Attention : Without switches for complete protection we do not give motor warranty! When the winding temperature is being exceeded without a complete motor protection switch, the motor can get badly damaged. Complete motor protection switches for 3 x 230 V available on request. * Whenn connecting a room thermostat remove link 3040531_201211 13

Switches 3-stage switch E3-7T with reclosing lock-out for 3-speed operation of one or more unit heaters with single-phase A.C. motors and complete motor protection. supply cable Fan motor with thermal cutout Operation voltage 230 V Max. capacity 7 A Weight 4,5 kg Prot. class IP 40 Part no. 27 01 064 Locking switch-off at winding overtemperature (motor). Reclosing: switch position 0, then select required stage. Contact for heating requirements. * When connecting a room thermostat remove link H1 = Service H2 = Interruption S1/K1 = Contact seizure depending on manufacture type Contact 3-4 heating requirements 3-stage switch D 3-4 with reclosing lock-out for 3-speed operation of one or more unit heaters with complete motor protection Fan motor with thermal cutout Link acc. to motor typeplate Operation voltage 400 V Control voltage 230 V Max. capacity 4 A Weight 8,0 kg Prot. class IP 20 Part no. 27 01 065 Locking switch-off at winding overtemperature (motor). Reclosing: switch position 0, then select required stage. Contact for heating requirements. * When connecting a room thermostat remove link H1 = Service H2 = Interruption S1/K1 = Contact seizure depending on manufacture type Contact 3-4 heating requirements F2, F3, F4 = 5 AT 14 3040531_201211

Control Devices for Damper Actuators Automatic relay A1 Auxiliary relay for the automatic operation of the fresh air damper with an actuartor 230 V "ON-SHUT". The automatic relay A1 switches the actuator to position "SHUT", if the LH-unit is switched off or if the anti-frost thermostat is activated. Switching on the LH-unit, the actuator switches to position "ON". Actuator Open-Shut Reverse function by changing of 2 and 3 Automatic relay A1 Anti-frost thermostat Selection switch fresh air/mixed air (on site) Control voltage 230 V Max. capacity 3 kw Weight 0,5 kg Prot. class IP 54 Part no. 79 65 020 Switch Actuator Open/Shut Reverse function by changing of 2 and 3 Automatic relay A1 Automatic relay A1S Auxiliary relay with integrated position transmitter for the automatic operation of the mixed air damper by means of a stepless actuator 230 V. N L1 M 1~ 3 1 2 Actuator stepless The automatic relay A1S switches the actuator to the position set on the position transmitter, if the LH-unit is switched off or if the anti-frost thermostat is activated. Switching on the LH-unit, the actuator switches to the position set at the position transmitter. A1S 8 9 11 3 4 2 1 1 3 Position transmitter 2 10 K F1 T 3,15 A Control voltage 230 V Max. capacity 3 kw Weight 0,5 kg Prot. class IP 54 Part no. 79 65 012 Control device A2 A1 K L1 L2 L3 N 3040531_201211 15

Thermostats Room thermostat Max. current at 230 V / 50 Hz Heating: 10(5) A; Venting: 5(2) A Thermal feed-back Temperature range 5-30 C Differential ± 0,5 K Protection class IP 30 Part no. 27 34 000 Room thermostat mith summer-winter-switch Step switch Room thermostat Max. current at 230 V / 50 Hz Heating: 10(4) A; Venting: 5(2) A Thermal feed-back Temperature range 5-30 C Differential ± 0,5 K Protection class IP 30 Part no. 27 34 700 Room thermostat Heavy-duty-design 1 3 2 J Max. current at 230 V / 50 Hz Heating: 16(4) A; Venting: 8(4) A Temperature range 0-40 C Differential ± 0,75 K Protection class IP 54 Part no. 27 35 300 Room thermostat clock with weekly program external remote sensor (optional) Max. current 10(4) A at 230 V / 50 Hz Temperature range 5-40 C Differential adjustable 2-10 K Differential ± 0,1up to 3 K Storage locations 16 Function reserve 15 minutes Shortest switching interval 10 minutes Protection class IP 20 Part no. 27 44 079 Remote sensor for room thermostat clock Plastic housing 52 x 50 x 35 mm Screw connection M16 Protection class IP 54 Part no. 27 35 410 Anti-frost thermostat 1 2 4 J Max. current 10 A at 230 V / 50 Hz Range 4,5 C bis 22 C Differential 2,5 K Prot. class IP 43 Wiring of anti-frost thermostat in line with thermal cutouts! LH 25 40 63 100 Part no. 27 30 050 27 30 150 16 3040531_201211

Control System WRS BML ventilation programming module Wall mounting base room-dependent temperature control control by rotary selector with key function 4 function keys for frequently used functions (info, temperture, speed adjustment, fresh air proportion) installation either inside the ventilation control unit or, as remote control, in a wall mounting base only one BML ventilation programming module required to control up to 7 zones demand-optimised boiler water temperature demand via ebus ebus interface wall mounting base for use with the BML ventilation programming module as remote control. LM1 Ventilation control unit (incl. room temperature sensor) ventilation module to control air heaters with a two-stage motor easy controller configuration by selecting one of the preset system versions demand-optimised room temperature control via air heater speed control of the heating circuit pump control of one heat source demand-optimised boiler water temperature demand via ebus ebus interface with automatic energy management LM2 ventilation control unit ventilation module LM2 to control the room temperature via speed or mixing valve 2-stage motor control in conjunction with ventilation module LM1, or variable motor control in conjunction with EC motor or external inverter (0-10 V) easy controller configuration by selecting one of the preset system versions control of one heat source demand-optimised boiler water temperature demand via ebus ebus interface with automatic energy management control of mixed air damper induction louvre control Outside or room temperature sensor Radio clock for synchronising the clock inside the control unit with the DC77 transmitter Radio clock with outside temperature sensor for synchronising the clock inside the control unit with the DC77 transmitter, and capturing the outside temperature Supply air sensor and sensor retainer 3040531_201211 17

Control System WRS Ventilation control unit LM1 with BML Description: This configuration is used for heating buildings in conjunction with air heaters. The room temperature is captured by a sensor and the fan, the heating circuit pump and the heat source are switched on or off depending on demand. If the temperature deviation (set room temperature to actual room temperature) is low, the fan is operated in stage 1. If the temperature deviation is greater, it is switched to stage 2. Example: Unit heater, heating with room temperature control OS BML LM1 supply heating circuit pump room sensor Installation diagram: unit heater boiler BML LM1/X1 X1/K1 supply Netz X1/eBus 2 X1/B2 X1/M2 B1 X1/M1 X1/B3 6 4 5 No. Description 1 room sensor 2 outside sensor 3 external release 4 2-stage motor 5 heating circuit pump 6 heat source 1 3 18 3040531_201211

Ventilation control units LM1 and LM2 with BML Description: Example: Unit heater, heating with room temperature control, mixing valve control, motor control, 2-stage Control System WRS This configuration is used for heating buildings in conjunction with air heaters. The room temperature is captured by a sensor and the fans, the heating circuit pump, the heating circuit mixing valve and the heat source are switched on or off depending on demand. AF BML LM1 LM2 supply LD15 supply HCP mixing valve supply air sensor room sensor anti-frostthermostat Installation diagram: unit heater BML LM1/X2 LM1/X1 mixed air LM2/X1 LM2/X2 induction louvre ceiling sensor boiler Heizkessel supply Netz supply Netz SS X2/M1 3 X1/B2 14 X2/B3 X1/B1 X1/B5 X2/M2 B1 No. Description 1 room sensor 2 supply air sensor 4 X1/B4 X1/Y3 8 2 7 5 13 X1/Y2 M1 X1/K1 3 outside sensor ebus 4 ceiling sensor 9 5 external release 7 anti-frost thermostat 8 induction louvre 9 2-stage motor 1 X1/Y1 11 X1/M2 10 12 10 heating circuit pump 11 heating circuit mixing valve 12 heat source 13 mixed air damper 14 LD15, ceiling fan 3040531_201211 19

Control System WRS LM2 Ventilation control unit with BML Description: This configuration is used for heating buildings in conjunction with air heaters. The room temperature is captured by a sensor, and the fans, the heating circuit pump, the heating circuit mixing valve and the heat source are switched on or off depending on demand. The extract air fan is activated depending on the fresh air proportion. Example: Unit heater, heating with room temperature control, mixing control, motor control with electronic 5-stage speed regulator BML OS electronic 5-stage regulator electronic 5-stage regulator LM2 supply extract air unit Installation diagram: supply mixed air unit supply mixed air HCP mixing valve induction louvre supply air sensor ceiling sensor anti-frost thermostat room sensor boiler supply supply No. Description 1 room sensor supply supply 2 supply air sensor 3 outside sensor 4 ceiling sensor 5 mixed air damper 6 fan 7 frequency inverter 8 heating circuit pump 9 heating circuit mixing valve 10 heat source 11 anti-frost thermostat 12 induction louvre 20 3040531_201211

Actuators / Push-button Actuator ON-SHUT 230 V / 50 Hz Relay A1 4 3 N Actuator for automatic opening and closing of the fresh air damper. Controlling only by automatic relay A1. 2 3 1 shut ZU open AUF N SM 220 Power consumption 11 VA Rotation direction reversible Torque drive 15 Nm Running time 90-150 sec. Protection class IP 42 Part no. 22 69 523 Stepless actuator 230 V / 50 Hz Actuator for automatic operation of damper, induction louvre and mixing valve. Controlling only by automatic relay A1 and position transmitter. Power consumption 5 VA Rotation direction reversible Torque drive 15 Nm Running time 100-200 sec. Protection class IP 42 Part no. 22 69 522 Push-button for 230V/50Hz actuator of induction louvre for surface or concealed installation; for progressive control of the induction louvre to optimize the air throw 53 113 83 L N surface/concealedtype push-button Control voltage 230 V Max. capacity 10 A Prot. class IP 20 1 Zu auxiliary 2 terminal on site Auf 1 2 4 5 Part no. 27 01 063 1 N 2 Zu 3 Auf LM 230 W actuator open-closed 230V induction louvre 3040531_201211 21

Intermediate Terminal Box Intermediate terminal box Intermediate terminal box for a parallel operation of several LH unit heaters. It is possible to wire one control device and three LH unit heaters or one control device, two LH unit heaters and an additional intermediate terminal box. LH unit heaters of different sizes and performances of up to the max. possible performance or rather the max. possible current of the switch or control device can be wired. Wiring according to the attached wiring diagrams. Connection of 3 LH unit heaters with an intermediate terminal box intermediate terminal box switch or control device Operation of 7 LH-units with intermediate terminal box intermediate terminal box intermediate terminal box intermediate terminal box switch or control device 22 3040531_201211

Maintenance / Frost Protection Measures Maintenance Attention: Do not clean electric heaters with water! For cleaning the heat exchanger from dust and dirt use vacuum cleaner or compressed air. For higher dirt accumulation use additionally commercial washing agents and luke warm water or compressed steam (not over 5 bar). Pull out the filter element on the access side to clean or to renew it. The filter element can be cleaned with the help of compressed air, batting or vacuum cleaner. All the remaining parts as motor, fan-impeller, mixing-box, adjustable fins and actuator are maintenance-free. Prior to finishing maintenance, check safe fastening of the LH-unit. Frost protection measures When unit is switched off: Drain all water-filled sections, blow out remaining water with compressed air! Steam heating coils being directly operated with fresh air have to be provided with steam on total height. Pump Before operation and after a longer rest period the pump has to be vented. For this purpose, the LH-unit has to be switched off. To proceed accordingly, remove plug acc. to sketch. When water is evacuated the plug is closed tightly again. The direction of rotation of the pump is marked with arrows on the type-plate. Pumps operating with AC always turn into the correct direction of rotation. Pumps operating with three-phase current have to be checked by removing the plug (threaded to the right) and by controlling the rotation of the shaft. 3040531_201211 23

Hydraulic Adjustment of Unit Heaters operating as a group General instructions The hydraulic adjustment of unit heaters is a precondition for an economic and optimized control within a group. The hydraulic adjustment aims at a correct flow rate through all unit heaters. Example 1: Individual adjustment via control valves ( in addition to the connection fittings). control valve unit heater VL boiler RL advantage: low expenditure of pipework disadvantage: pressure adjustment required for each unit heater Example 2: Pipework assembly according to the Tichelmann system (equally long pipes per unit heater replace the individual adjustment) unit heater VL boiler RL advantage: no pressure adjustment required disadvantage: higher expenditure of pipework 24 3040531_201211

Rain protection hood and roof lead-in box Roof lead-in box and rain protection hood are supplied sepa rately. The rain protection hood is provided with a bird screen as standard. As an option a non-return damper may be supplied for the installation into the rain protection hood, on site. Roof fastening As an option and on extra price it is possible to supply 4 fastening angles for fitting the roof lead-in box. Fitting of fastening angles to be done on site because of different types of roofs and variable pitch. External fitting of fastening angles as well possible Roof lead-in box Roof 4 x fastening angles to be adapted to the pitch of the roof Notice: The fastening angles are exclusively suitable for fitting the roof lead-in box. They are not designed for carrying the additional weight of unit components installed underneath the roof lead-in box. Roof sealing In order to facilitate the sealing of the roof on site, it is possible to supply a covering collar as an optional accessory, not fitted. Installation and fitting in accordance with the drawing: Rain protection hood Covering collar Installation and sealing on site X Fit sealing material on site (included) X Roof sealing (on site) Roof lead-in box Covering collar Installation and sealing on site 3040531_201211 25

Rain protection hood and roof lead-in box Flexible connection A unit heater or mixing box are connected to the internal flange of the roof lead-in box (matching bore holes) via a flexible connection "Q". In this case the roof lead-in box has to be on the roof and the mixing box, filter section or unit heater underneath the roof. Roof lead-in box Flange of angle profile on the whole perimeter; generally spot-welded Unit heater Flexible connection 4 x angle brackets of unit heater, only fitted when ordered Non-flexible connection Direct fitting of unit heater or mixing box to the external angle flange. This flange is provided with the matching bore holes for the angle brackets of the unit heater, mixing box or filter section on the whole perimeter. Roof lead-in box Flange of angle profile on the whole perimeter; generally spot-welded Unit heater 4 x angle brackets of unit heater, only fitted when ordered 26 3040531_201211

Notes 3040531_201211 27

Wolf GmbH Postfach 1380 84048 Mainburg Tél. 08751/74-0 Fax 08751/741600 Internet : www.wolf-heiztechnik.de