E-Chef Hot Food Table Installation and Operation Manual

Similar documents
Insta-Therm Series Service, Installation and Operation Manual

Concepts Serving Systems

E-Chef Hot Food Table

Chef Base Refrigerators

MHC-1 Holding Cabinet Series Service, Installation and Operation Manual

COUNTER TOP REFRIGERATION MODEL SERIES HUBM-2RB/HUBM-2FB/HUBM-3.5RB/HUBM-3.5FB HUBM-2R/HUBM-2F/HUBM-3.5R/HUBM-3.5F

Solid Door Top Mount Reach-In Freezer

Sandwich/Salad Table Under-counter Refrigerator Worktop Refrigerator

Glass Door Merchandiser Refrigerator and Freezer

Important Information Read Before Use Please Save These Instructions! ASM SERIES Drop-In Air Screen Merchandisers

Important Information Read Before Use Please Save These Instructions!

Compact Refrigerators & Freezers

FlexiShield Food Shields

Milk, Ice Cream and Milk & Ice Cream Dispensers

INSTALLATION & OPERATION MANUAL

INSTALLATION & OPERATION MANUAL

INSTALLATION & OPERATION MANUAL

GLASS DOOR MERCHANDISER REFRIGERATOR & FREEZER. Installation, Operation and Maintenance Instructions

Compact Refrigerators & Freezers

Duke Manufacturing Co.

INSTALLATION & OPERATION MANUAL

Models: DB-2-HF, DB-3-HF, DB-4-HF, and DB-5-HF. For Service Information, Call

INSTALLATION & OPERATION MANUAL

INSTALLATION & OPERATION MANUAL

Installation & Operation Manual

Delfield. Important Information Read Before Use Please Save These Instructions!

Instruction Manual. Bottle Cooler. Models HBC-50 (-S) HBC-65 (-S) HBC-80 (-S) HBC-95 (-S) hoshizakiamerica.com. Issued: Revised:

Installation & Operation Manual

Upright Chiller & Freezer Service, Installation and Care Manual

Direct Draw Equipment

User Manual. Commercial School Milk Cooler User s Manual. Commercial School Milk Coolers: MC34, MC49, MC58

INSTRUCTIONS. Installation, operation and care of HD SERIES HOT DELI DISPLAY CASES. MODEL HD5 Full-Service IMPORTANT READ BEFORE USING DISPLAY CASE

SERIES NAV S Display Merchandisers

OWNER S MANUAL INSTRUCTIONS, INSTALLATION, OPERATION, MAINTENANCE RHPE & RTGE SERIES (ELECTRIC COUNTERTOPS) RETAIN THIS MANUAL FOR FUTURE REFERENCES.

Original Instructions Installation, Operation and Maintenance Manual

UNDERCOUNTER REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

REFRIGERATED PREP TABLES Installation, Operation and Maintenance Instructions

ELECTRIC DECK OVENS INSTALLATION & OPERATING MANUAL

ELECTRIC COUNTERTOP DECK OVEN INSTALLATION & OPERATING MANUAL

Bottle Coolers. Manual for installation, use and Maintenance

User Manual

INSTALLATION AND OPERATION MANUAL

Fried Food Holding Station

RCM-77. Instruction Manual. G-Series Cooler. U.S. Patent No. 8,215,125 RECHARGE COLD MERCHANDISER

INSTALLATION & OPERATION MANUAL

Domino s Pizza International Makeline

International Drop Ins

01694-REVC_081315_ENGLISH

PLEASE READ THIS MANUAL BEFORE USING YOUR APPLIANCE. KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE.

WELLS COUNTERTOP 6411 & LL Series SOUP COOKERS and COOK N HOLD WARMERS

GENERAL LABORATORY REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

OWNER S MANUAL INSTRUCTIONS, INSTALLATION, OPERATION, MAINTENANCE RRE SERIES (ELECTRIC RANGE & CONVECTION)

User Manual. Commercial Chest Freezer User s Manual 360CF5, 360CF8, 360CF14, 360CF18

ELECTRIC COMPACT DECK OVEN INSTALLATION - OPERATION - MAINTENANCE

Professional Warming Drawer and Warming Drawer Cabinet

KPS-E, KLS-E AND KLT-E SERIES

INSTRUCTIONS. Installation, operation and care of CLD COLD SERIE MULTIDECK COLD FOOD DISPLAY CASES IMPORTANT READ BEFORE USING DISPLAY CASE

User Manual / Installation Instructions

Refridgerated Topping Rail Model: RTR-8 Intended for other than household use. Unit must be kept clear of combustibles at all times.

RCM-2. Instruction Manual. G-Series Cooler. Manual is for the following models: RCM-2-N13EB. **Patent Pending** RECHARGE COLD MERCHANDISER

Operation Manual and Parts Directory

G-10s. Instruction Manual. G-Series Cooler UPRIGHT COOLER. Part No.11IPA

Technical Manual and Replacement Parts List. Mobile Freezer

Refrigerators. Technical Manual and Replacement Parts List FORM NO REV H MODEL SKTTR7FW MODEL SKC1220W

Pocket Hardmount. Preventative Maintenance.

G-7s. Instruction Manual. G-Series Cooler COUNTERTOP COOLER. Part No.11IPA

INSTALLATION & OPERATION MANUAL

Fudge Server. Fudge Server with Pump MODEL: FSP. Thank You MODEL: FS COMPLETE UNIT BASE ONLY COMPLETE UNIT BASE ONLY 83208

USER MANUAL Gas Countertop Charbroilers

Please read this manual completely before attempting to install, operate or service this equipment

Fudge Server. Fudge Server with Pump. Thank You MODEL: FS MODEL: FSP

CRISP N HOLD FRIED FOOD HOLDING CABINET MODELS: CNH14, CNH18, CNH28, CNH40 OWNERS / OPERATORS MANUAL

INSTALLATION AND OPERATION MANUAL

Compact Refrigerators & Freezers

USE AND CARE GUIDE COMBINATION KITCHENS. C301 Series C301 AUTO Series C39 Series C39 AUTO Series C48 Series C60 Series

Congratulations on your purchase on your Commercial Pro International product. Provided in this manual are necessary details to ensure efficient,

INSTALLATION & OPERATION MANUAL

User s Manual Warm N Cozy

Food Server Supreme. Butter Server Supreme. Thank You MODEL:

I N ST ML (3-PAN, SELF-SERVICE) ML (4-PAN, SELF-SERVICE)

Operation Manual and Parts Directory

ELECTRICAL DATA: FEATURES: SHIPPING INFORMATION: FOOD WARMING/ MERCHANDISING CABINET. 15 Width 7 Width

Chiller with BP-1 1/2 oz Pump

Cleveland. Operators Manual. Direct Steam Table Top Kettles. Installation & Operation. Table-Top Direct Steam Kettles. SD Stands. Kettles on SD Stands

MODULAR REFRIGERATOR. Français p. 16 Español p. 31 ITEM # MODEL #BG179B

HOLDING DRAWERS INTENDED FOR OTHER THAN HOUSEHOLD USE THIS MANUAL FOR FUTURE REFERENCE KEPT CLEAR OF COMBUSTIBLES AT ALL TIMES

REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

ADD FLUID 300 NDNL 300 CT 300 OC 700 NDNL 725 NDNL 950 NDNL

INSTALLATION & OPERATION MANUAL

CNH12LP CNH28 CNH40 CNH28LPC

Hot Dog Hutch. Models HDH-3, HDH-3DR, & HDH-4 owner s manual. Manufacturing Numbers:

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions

RCM-2. Instruction Manual. G-Series Cooler. Manual is for the following models: RCM-2-N13EB. **Patent Pending** RECHARGE COLD MERCHANDISER

STAR-MAX GAS GRIDDLES MODELS 615MA 624MA 636MA 648MA 615TA 624TA 636TA 648TA 624TSPA 636TSPA 648TSPA

BACK BAR REFRIGERATION Installation, Operation and Maintenance Instructions

CARE & CLEANING GUIDE. Bathroom & Kitchen Products

WELLS BUILT-IN HW-Series COOK N HOLD WARMERS with THERMOSTAT CONTROL

VENTLESS EXHAUST HOOD OPERATORS MANUAL AND PARTS LIST REV. MAY 2016

PRO SERIES GAS FRYERS OWNER S MANUAL

Outdoor Refrigerator USER S MANUAL

Transcription:

E-Chef Hot Food Table Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment! Notify carrier of damage! Inspect all components immediately. CAUTION Important Information Read Before Use Please Save These Instructions! March 2013

Important Warning And Safety Information Read This Manual Thoroughly Before Operating, Installing, Or Performing Maintenance On The Equipment. Failure To Follow Instructions In This Manual Can Cause Property Damage, Injury Or Death. Do Not Store Or Use Gasoline Or Other Flammable Vapors Or Liquids In The Vicinity Of This Or Any Other Appliance. Unless All Cover And Access Panels Are In Place And Properly Secured, Do Not Operate This Equipment. This Appliance Is Not Intended For Use By Persons Who Lack Experience Or Knowledge, Unless They Have Been Given Supervision Or Instruction Concerning Use Of The Appliance By A Person Responsible For Their Safety. This Appliance Is Not To Be Played With. Warning Do Not Clean With Water Jet. Do Not Use Electrical Appliances Inside The Food Storage Compartment Of This Appliance. CAUTION Observe the following: Minimum clearances must be maintained from all walls and combustible materials. Keep the equipment area free and clear of combustible material. Allow adequate clearance for air openings. Operate equipment only on the type of electricity indicated on the specification plate. Unplug the unit before making any repairs. Retain this manual for future reference. 2 For customer service, call (800) 733-8829, (800) 733-8821, (989) 773-7981, Fax (989) 773-3210, www.delfield.com

Contents E-Chef Hot Food Table Installation and Operation Manual Receiving & Inspecting...3 Serial Number Location...4 Warranty Information...4 Regulatory Certifications...4 Specifications...5 Installation...5 Operation...6 Maintenance...7 Wiring Diagrams...8 Replacement Parts...9 Standard Labor Guidelines...10 Notes...11 Receiving And Inspecting The Equipment Even though most equipment is shipped crated, care should be taken during unloading so the equipment is not damaged while being moved into the building. 1. Visually inspect the exterior of the package and skid or container. Any damage should be noted and reported to the delivering carrier immediately. 2. If damaged, open and inspect the contents with the carrier. 3. In the event that the exterior is not damaged, yet upon opening, there is concealed damage to the equipment notify the carrier. Notification should be made verbally as well as in written form. 4. Request an inspection by the shipping company of the damaged equipment. This should be done within 10 days from receipt of the equipment. 5. Check the lower portion of the unit to be sure legs or casters are not bent. 6. Also open the compressor compartment housing and visually inspect the refrigeration package. Be sure lines are secure and base is still intact. 7. Freight carriers can supply the necessary damage forms upon request. 8. Retain all crating material until an inspection has been made or waived. Uncrating the Equipment First cut and remove the banding from around the crate. Remove the front of the crate material, use of some tools will be required. If the unit is on legs remove the top of the crate and lift the unit off the skid. If the unit is on casters it can be "rolled" off the skid. For customer service, call (800) 733-8829, (800) 773-8821, (989) 773-7981, Fax (989) 773-3210, www.delfield.com 3

Serial Number Location The serial number on all E-Chef Series models is printed on the tag located on the interior side panel. Always have the serial number of your unit available when calling for parts or service. A complete list of authorized Delfield parts depots is shown on the back cover of this manual. 2013 The Delfield Company. All rights reserved. Reproduction without written permission is prohibited. Delfield is a registered trademark of The Delfield Company. Warranty Information Visit http://www.delfield.com/minisite/service/warranty_info to: Register your product for warranty. Verify warranty information. View and download a copy of your warranty. Regulatory Certifications All Models are certified by: National Sanitation Foundation (NSF) Underwriters Laboratories (UL) Underwriters Laboratories of Canada (ULC) 4 For customer service, call (800) 733-8829, (800) 733-8821, (989) 773-7981, Fax (989) 773-3210, www.delfield.com

Specifications Model Overall Length Depth Height # Of Wells Volts, Hertz, Phase Amps NEMA Plug EHEI36L 36.00 (91cm) 31.50 (80cm) 36.00 (91cm) 2 120, 60, 1 20.0 N/A EHEI36C 36.00 (91cm) 31.50 (80cm) 36.00 (91cm) 2 120, 60, 1 20.0 5-30P EHEI48L 48.00 (122cm) 31.50 (80cm) 36.00 (91cm) 3 208/230, 60, 1 15.0/16.0 N/A EHEI48C 48.00 (122cm) 31.50 (80cm) 36.00 (91cm) 3 208/230, 60, 1 15.0/16.0 6-20P EHEI60L 60.00 (152cm) 31.50 (80cm) 36.00 (91cm) 4 208/230, 60, 1 20.0/22.0 N/A EHEI60C 60.00 (152cm) 31.50 (80cm) 36.00 (91cm) 4 208/230, 60, 1 20.0/22.0 6-30P EHEI74L 74.00 (188cm) 31.50 (80cm) 36.00 (91cm) 5 208/230, 60, 1 24.0/27.0 N/A EHEI74C 74.00 (188cm) 31.50 (80cm) 36.00 (91cm) 5 208/230, 60, 1 24.0/27.0 6-50P Installation Installation should only be done by personnel certified and licensed to install and maintain electrical appliances. Location Intended for indoor use only. Do not install the hot food table near any combustible objects or surfaces affected by heat or moisture. Leveling This unit must be level, both front and back and left to right, in order to maintain an equal water depth throughout the wells. Plumbing A waste connection is provided 26.5 (67.3cm) above the floor, 5.25 (13.3cm) from the right end. You must supply the required 1/2 connection at gate valve. Electrical connection Refer to the specification pages amperage data, the serial tag, your local code or the National Electrical Code to be sure the unit is connected to the proper power source. A protected circuit of the correct voltage and amperage must be run for connection of the line cord, or permanent connection of the unit. The power switch must be turned to OFF and the unit disconnected from the power source whenever performing service or maintenance functions. For customer service, call (800) 733-8829, (800) 773-8821, (989) 773-7981, Fax (989) 773-3210, www.delfield.com 5

Operation Before the unit is used the first time for serving, turn the temperature knob to HIGH and heat the well for 30 minutes. Any residue or dust that adhered to the heater element(s) will burn off during this initial preheat period. When using thick sauces always operate the hot food well filled with water. This will provide a more uniform temperature for the sauce. Steam can cause serious burns. Always wear some type of protective covering on your hands and arms when removing lids or pans from the unit. Lift the lid or pan in a way that will direct escaping steam away from your face and body. Never place food directly into the well. Always use pans. Although these models may be operated either with or without water in the wells, wet operation is recommended. Always place covers on pans when not serving to prevent food from drying out and to reduce your operating cost. For most efficient operation when empty, keep covered insets in each well during preheating and when the well is not in use. Do not put food down drain. Wet operation 1. Fill food well with two inches of water. For quicker pre-heating, use hot water to fill the well. 2. Turn the control to HIGH and pre-heat the warmer for 30 minutes. For fastest pre-heating place covers or empty pans in well. 3. After pre-heating, set the control to your desired serving temperature. Only 4 (10cm) deep insets should be used with a wet food well. Dry operation 1. Pre-heat the well on HIGH for approximately 15 minutes. For fastest pre-heating place covers or empty pans in well. 2. After pre-heating, set the control to your desired serving temperature. Only 6 (15cm) deep insets should be used with a dry food well. When operated dry, the bottom of the food well will discolor. A mild abrasive cleaner is recommended to clean this discoloration. Temperature Water in wells...160 F to 180 F Product in pans...140 F to 160 F 6 For customer service, call (800) 733-8829, (800) 733-8821, (989) 773-7981, Fax (989) 773-3210, www.delfield.com

Maintenance Caster Maintenance Wipe casters with a damp cloth monthly to prevent corrosion. The power switch must be turned to OFF and the unit disconnected from the power source whenever performing service, maintenance functions or cleaning the refrigerated area. Stainless Steel Care and Cleaning To prevent discoloration or rust on stainless steel several important steps need to be taken. First, we need to understand the properties of stainless steel. Stainless steel contains 70-80% iron, which will rust. It also contains 12-30% chromium, which forms an invisible passive film over the steel s surface, which acts as a shield against corrosion. As long as the protective layer is intact, the metal is still stainless. If the film is broken or contaminated, outside elements can begin to breakdown the steel and begin to form discoloration or rust. Proper cleaning of stainless steel requires soft cloths or plastic scouring pads. NEVER USE STEEL PADS, WIRE BRUSHES OR SCRAPERS! Cleaning solutions need to be alkaline based or non-chloride cleaners. Any cleaner containing chlorides will damage the protective film of the stainless steel. Chlorides are also commonly found in hard water, salts, and household and industrial cleaners. If cleaners containing chlorides are used be sure to rinse repeatedly and dry thoroughly. Routine cleaning of stainless steel can be done with soap and water. Extreme stains or grease should be cleaned with a non-abrasive cleaner and plastic scrub pad. Always rub with the grain of the steel. There are stainless steel cleaners available which can restore and preserve the finish of the steels protective layer. Early signs of stainless steel breakdown are small pits and cracks. If this has begun, clean thoroughly and start to apply stainless steel cleaners in attempt to restore the passivity of the steel. Never use an acid based cleaning solution! Many food products have an acidic content, which can deteriorate the finish. Be sure to clean the stainless steel surfaces of ALL food products. Common items include, tomatoes, peppers and other vegetables. Units with pans should be operated with pans in place. Operating the unit without all pans in place will lower efficiency and may damage the unit. Plexiglas Food Shield Cleaning Wet a clean cloth with lukewarm water and dishwashing liquid. Apply only light pressure, rinse with clear and blot dry with a damp chamois. For excessively dirty surfaces, rinse surface dirt off before washing. Fine scratches will disappear when you polish by hand with a plastic cleaner polish. Never use window sprays, kitchen scouring compounds or solvents such as acetone, gasoline, benzene, alcohol, carbon tetrachloride or lacquer thinner to clean plexiglas. For customer service, call (800) 733-8829, (800) 773-8821, (989) 773-7981, Fax (989) 773-3210, www.delfield.com 7

Wiring Diagrams 120 Or 208-230V Single Phase Models L1 G L2 (Neutral On 120V Models) "Infinite" Control Heater 1 Pilot Light Heater 2 Pilot Light Heater 3 Pilot Light Heater 4 Pilot Light Heater 5 Pilot Light Pilot Light (Furnished) H1 H2 P L1 L2 1000 W - 120V Or 1000/1222 W - 208/230V Heating Element Line Wires To Additional Food Warmers Infinite Control With Off Position 8 For customer service, call (800) 733-8829, (800) 733-8821, (989) 773-7981, Fax (989) 773-3210, www.delfield.com

Replacement Parts Part Name Delfield Part # Cutting board pin cap 1701000 Cutting board pin screw 9321076 Brass cutting board hinge pin 3234360 Polyethlene board, model EHEI36 096-004-0031 Polyethlene board, model EHEI48 096-004-0032 Polyethlene board, model EHEI60 096-004-0033 Polyethlene board, model EHEI74 096-004-0034 Delfield Food Well (DFW) Assembly With Infinite Control Key Part Name Delfield Part # - Complete assembly, 120V, infinite w/drain 000-516-0000 - Complete assembly, 208-230V, infinite w/drain 000-518-0000 1 Deflector plate 026-061-0001 10 2 Bottom cover 026-103-0001 2 3 Food well, with drain 323-4361 4 Screw 932-1353 5 Element, 120V 219-4006 7 4 Element, 208-230V 219-4007 6 Screws (2) 932-1379 7 Insulation 3434663 8 Thermostat non-adjustable 219-4335 9 Screw 932-1007 10 Drain cover 027-210-0001 11 Screws (2) 932-1007 1 9 6 8 12 Infinite control, 120V 219-4107 Infinite control, 208-230V 219-4110 5 13 Infinite control knob 323-4557 14 Pilot light, red, 120V 219-4190 11 8.50 Pilot light, amber, 208-230V 219-4095 2.31 Clear 3 14 Infinite Control 12 13 For customer service, call (800) 733-8829, (800) 773-8821, (989) 773-7981, Fax (989) 773-3210, www.delfield.com 9

Standard Labor Guidelines To Repair Or Replace Parts On Delfield Equipment Advice and recommendations given by Delfield Service Technicians do not constitute or guarantee any special coverage. A maximum of 1-hour is allowed to diagnose a defective component. A maximum of 1-hour is allowed for retrieval of parts not in stock. A maximum travel distance of 100 miles round trip and 2-hours will be reimbursed. Overtime, installation/start-up, normal control adjustments, general maintenance, glass breakage, freight damage, and/or correcting and end-user installation error will not be reimbursed under warranty unless pre-approved with a Service Work Authorization from Delfield. You must submit the number with the service claim. LABOR OF 1-HOUR IS ALLOWED TO REPLACE: Infinite Switch Hi-limit/Thermal Protector Switch LABOR OF 2 HOURS TO REPLACE: Heating Element 10 For customer service, call (800) 733-8829, (800) 733-8821, (989) 773-7981, Fax (989) 773-3210, www.delfield.com

Notes For customer service, call (800) 733-8829, (800) 773-8821, (989) 773-7981, Fax (989) 773-3210, www.delfield.com 11

Mt. Pleasant, MI Covington, TN Thank you for choosing Delfield! Help is a phone call away. Help our team of professional, courteous customer service reps by having your model number and serial number available at the time of your call (800) 733-8829. Model: S/N: Installation Date: For a list of Delfield s authorized parts depots, visit our website at www.delfield.com Register your Delfield warranty online. Go to www.delfield.com under the service tab to complete. Delfield 980 S. Isabella Rd., Mt. Pleasant, MI 48858, U.S.A. (989) 773-7981 or (800) 733-8829 Fax (989) 773-3210 www.delfield.com Delfield reserves the right to make changes in design or specifications without prior notice. 2013 The Delfield Company. All rights reserved. Printed in the U.S.A. DMECHEF 03/13 9291472