ADVANTAGE 1200 EXTRACTOR

Similar documents
ADVANTAGE-400H EXTRACTOR

ADVANTAGE-100H-SC EXTRACTOR

120V CAUTION: DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTION MANUAL IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY

CAUTION: DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTION MANUAL

TERMINATOR 120V CAUTION: DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTION MANUAL

MIRAI EXTRACTOR 100V DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THESE INSTRUCTIONS IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY

COBRA -H EXTRACTOR 120V

COBRA -300H EXTRACTOR

DO NOT OPERATE THE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THE INSTRUCTIONS IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY

HP310-C EXTRACTOR 120V

SOLUS-500 EXTRACTOR 120V

INFORMATION & OPERATING INSTRUCTIONS

HHP-300 EXTRACTOR 120V

SOLUS-310 EXTRACTOR 120V

SOLUS-310R EXTRACTOR

SOLUS-310 EXTRACTOR 120V

XLT-60 EXTRACTOR 120V CAUTION: DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTION MANUAL

FLOOD KING 120V. 2. Keep all filters clean. Do not operate the machine if the filters are clogged.

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE

AGITATOR V DO NOT OPERATE THE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THESE INSTRUCTIONS IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY

Xaact Spot. Xaact Hot Spot

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE

Predator CXC & CHX Spotter 230V

SPOTTER CAUTION: DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTION MANUAL

BEFORE OPERATING THE MACHINE: WARNING

TFC 400. OPERATOR MANUAL Clarke MODEL /09 Rev C Document Number

PREDATOR CXC150 IMPORTANT SAFETY INSTRUCTIONS READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE OPERATING OR SERVICING MACHINE

MICRO CLEANER. OPERATOR MANUAL Advance MODEL /10 Rev E Document Number

FiberPRO 2.5 H. Heated Spot Extractor. Operator and Parts Manual E

FiberPRO. 15 Series. High Pressure Carpet Extractors. Operator and Parts Manual E E E

MC MC MC MC MC833130

MAXUM 5 5 Gallon Box Extractor

Tornado Operation & Maintenance Manual

PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650

SAFETY OPERATION & MAINTENANCE MANUAL X-405 CARPET EXTRACTOR This unit is intended for commercial use.

Flood Pumper Plus. Water Transfer Machine. Operator and Parts Manual. Model No.: Rev. 00 (11-99)

OPERATOR'S MANUAL. IMPORTANT: READ OPERATOR'S MANUAL CAREFULLY Please fill out & return your warranty card! DP80405

EXTRACTOR Operation & Maintenance Manual

PREDATOR CXH100 IMPORTANT SAFETY INSTRUCTIONS READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE OPERATING OR SERVICING MACHINE

OPERATION MANUAL ALPHA ALS WET / DRY IMPORTANT SAFETY INSTRUCTIONS. Read all instructions before using or servicing machine.

SAFETY PRECAUTIONS. 2) Before operating machine: - Make sure all safety devices are in place and operate properly.

SAFETY OPERATION & MAINTENANCE MANUAL X-612 CARPET EXTRACTOR

User Manual AIR HOG. Vacuum Booster REV. 3/20/ Stowe Dr. Poway, CA P: (858) F: (858)

Sanitaire. Owner s Guide. 10 GALLON Box Extractor SC6088 Series IMPORTANT

PREDATOR CX3 IMPORTANT SAFETY INSTRUCTIONS READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE OPERATING OR SERVICING MACHINE

HERCULES MINI CANISTER VACUUM CLEANER USER GUIDE MODEL: BGC1000

As part of the V.I.P. family, you are entitled to the best protection by one of the most comprehensive warranties in the industry.

Safety, Operation, and Maintenance Manual with illustrated parts list

Operator Manual - Workman Wet/Dry Vacuums IMPORTANT SAFETY INSTRUCTIONS

Commercial Spotter Model number PS35

MAXUM Gallon Box Extractor

OWNER S MANUAL IMPORTANT: READ OWNER S MANUAL CAREFULLY

6-Gallon Carpet Extractor Series

IMPORTANT SAFEGUARDS WARNING

WIDE AREA VACUUM MODEL PF2030 WARNING: OPERATOR MUST READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE OPERATING THIS EQUIPMENT.

OPERATOR S MANUAL & PARTS LIST

17 GALLON PROFESSIONAL RESTROOM CLEANER

Prospector PE300 Extractor With Heat

Workman 3, 6, & 10-Gallon Wet/Dry Vacuums. Technical Information & Safety Page 3, 4

Workman 3, 6, & 10-Gallon Wet/Dry Vacuums. Technical Information & Safety Page 3, 4

SSS Speedster 600 (Model SP-600, #56001) SSS Speedster 1000 OPERATION SERVICE PARTS CARE. SSS Speedster 1000 SSS Speedster 600

Operator & Parts Manual Self_Contained Extractor ie U REV.05( ) INTERNATIONAL CLEANING EQUIPMENT

INSTRUCTION MANUAL WET / DRY VACUUM VC HP V 60 Hz 7A. Gal

π H-2268 SANITAIRE UPRIGHT VACUUM SAFETY uline.com

Pump Out Vacuums Polyethylene & Steel

SAFETY, OPERATION AND MAINTENANCE MANUAL. MX-1408 SELF-CONTAINED EXTRACTOR This unit is intended for commercial use.

GENIUS 14 GENIUS 18 OPERATING & MAINTENANCE

SAFETY, OPERATION AND MAINTENANCE MANUAL. DRY VACUUM CLEANER This unit is intended for commercial use. SAVE THESE INSTRUCTIONS

Owner s Manual MODEL: SCT-1. Before operating the vacuum, please read these instructions completely.

8070 Mytee Lite. Instructions for. Please read before use. Register your product at support/register.

C-Box 100, H-Box 200 & H-Box 500

HOTSPOT. Two Gallon Pump Up Spotter OPERATING & MAINTENANCE

Safety, Operation and Maintenance Manual with Parts List

WET/DRY VACUUM Models PF51, PF53, PF55, PF57

Dominator 200 PSI 13 Gallon

10QT AND 6QT BACKPACK VACUUMS

Operations and Safety Manual

PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650

GALAXY 5 Owner s Manual & Parts List

Dominator 500 PSI 17 Gallon

INTELLI-VAC 14 INTELLI-VAC 18

Parts and Instruction Manual TRS 14 Total Recovery System

PACER 30 VACUUM IMPORTANT SAFETY INSTRUCTIONS READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE OPERATING OR SERVICING MACHINE

If additional information is needed, please contact EDIC at: or

CRV Clean Room Vacuum

WET/DRY VACUUMS POLYETHYLENE, POLYPROPYLENE & STEEL

Operating Instructions

Nilfisk Inc Winnetka Avenue North Minneapolis, MN REV.03( ) VF80189

3 GALLON SELF-CONTAINED EXTRACTOR

BEXT Pro EXTRACTOR. Parts List Models: (400H), , (100H), (100) Form No /11 revised 4/13

OWNER'S MANUAL IMPORTANT: READ OWNER'S MANUAL CAREFULLY BLACK CAT FOR YOUR CONVENIENCE, RECORD THE FOLLOWING IMPORTANT INFORMATION MODEL:

IMPORTANT SAFETY INSTRUCTIONS. WARNING - To reduce the risk of fire, electric shock, or injury : SAVE THESE INSTRUCTIONS CONTENTS

PE500 Carpet Extractor

SHOVELNOSE WET & DRY VAC OWNERS MANUAL. IMPORTANT: READ OWNERS MANUAL CAREFULLY Please fill out & return your warranty card! SN18WD MODEL# SERIAL#

Prospector PE500 Extractor WIth Heat

IMPORTANT SAFETY INSTRUCTIONS

Operator & Parts Manual Wet / Dry Vacuum Cleaner iw U REV.02( ) INTERNATIONAL CLEANING EQUIPMENT

Explorer CleaningPartsDirect.com Carpet Extractor. Operator and Parts Manual. Home Find... Go To.. Model No.: Can.

WET & DRY VACUUM CLEANER

457LAVBP10QT LAVEX HEPA BACKPACK VACUUM CLEANER

Transcription:

ADVANTAGE 100 EXTRACTR 10V INFRMATIN & PERATING INSTRUCTINS CAUTIN: D NT PERATE MACHINE UNTIL YU HAVE READ ALL SECTINS F THIS INSTRUCTIN MANUAL IMPRPER USE F THE MACHINE WILL VID THE WARRANTY 56041934 1. Always use a defoamer when foaming occurs to prevent vacuum motor damage.. Connect the machine to a properly grounded outlet. 3. Keep machine from rain, snow, and extremes in temperatures. Store the machine in a heated location. Use the machine indoors. Do not use outdoors. 4. Use approved chemicals only. N SLVENTS. 5. Wear gloves or use rags when removing quick disconnects to prevent burns. 6. Never use water above 130º F/54º C in the solution tank. 7. Never turn on the solution pump without your solution line connected to the machine and the tool. 1-16-010

IMPRTANT SAFETY INSTRUCTINS The Advantage 100 is only suitable for commercial use, for example in hotels, schools, hospitals, factories, shops, and offices. The Advantage 100 is not intended for normal residential housekeeping purposes. NTE: Read all instructions before using this machine. When using any electrical appliance, basic precautions should always be followed, including the following warnings: WARNING! To reduce the risk of fire, electric shock, or injury: Do not leave the machine unattended when it is plugged in. Unplug the unit from the outlet when not in use and before servicing. To avoid electric shock, do not expose to rain or snow. Use and store indoors. Do not allow to be used as a toy. Close attention is necessary when used near children. Use only as described in this manual. Use only the manufacturer s recommended attachments. Never add water over 130º F/54º C to the solution tank. Do not use with damaged cord or plug. If the machine is not working as it should, has been dropped, damaged, left outdoors or dropped into water, return it to a service center. Do not pull by the cord, use the cord as a handle, close a door on the cord, or pull the cord around sharp edges or corners. Do not run the machine over the cord. Keep the cord away from heated surfaces. To unplug, grasp the plug, not the cord. Do not handle the plug, the cord, or the machine with wet hands. Extension cords must be 1/3 and no longer than 50 feet. Replace the cord or unplug immediately if the ground prong becomes damaged. Do not put any object into openings. Do not use with any opening blocked; keep free of dust, lint, hair, and anything that may reduce air flow. Keep loose clothing, hair, fingers, and all parts of body away from openings and moving parts. Do not pick up anything that is burning or smoking, such as cigarettes, matches, hot ashes, or any health endangering dusts. Do not use to pick up flammable or combustible liquids such as gasoline or use in areas where these liquids may be present. Turn off all controls before unplugging. Use extra care when cleaning on stairs. Connect to a properly grounded outlet only. Liquid ejected at the spray nozzle could be dangerous as a result of its temperature, pressure, or chemical content. Never turn on the solution pump without first connecting your solution hose to your machine and to your tool.

INSPECTIN: Carefully unpack and inspect your ADVANTAGE 100 for shipping damage. Each machine is tested and inspected before shipping. Any shipping damage incurred is the responsibility of the carrier. You should notify the carrier immediately if you notice damage to the box, the machine, or its parts. CLEANING SLUTINS: We recommend liquid cleaning chemicals. Powder chemicals may be used, but unless mixed very thoroughly they could cause a build-up in the pump, lines, and quick disconnects. Any problem caused by a chemical build-up is not covered by warranty. Use a neutral cleaner with a ph between 5 and 10 to avoid premature wear of the pump, seals, and/or other components. It is a good idea to test an inconspicuous area of the floor. MAINTENANCE: For optimum performance flush the machine with clear water at the end of each working day. nce a month, minimum, run a flushing compound through the machine to break up any mineral or chemical buildup that may have formed. The vacuum motor and the pump do not require any scheduled maintenance; however, the motor may require replacement brushes after 1000-1500 hours. Clean the body with an all-purpose detergent, and protect it with an automobile interior polish. Lubricate the wheels, castors, and quick disconnects with an all purpose silicone spray. PARTS AND SERVICE: Repairs, when required, should be performed by your authorized distributor who maintains an inventory of original replacement parts and accessories. Call the distributor from whom you purchased this machine if you need parts and service. Be sure to specify the machine model. Have your serial number handy. Serial Number: Model: ADVANTAGE 100 Purchase Date: Write the name and phone number of your distributor: (and be sure to register your warranty: go on-line to www.usproducts.com) 3

SWITCH PLATE MDEL (1): This identifies the model of your machine. 1 3 4 I I I 5 VACUUM SWITCH (): MDEL This push-button switch turns on the vacuum. The switch will illuminate when it is on. AUT DUMP SWITCH (3): This pump switch will illuminate when it is activated, and it will turn on the automatic pump-out pump. SLUTIN PUMP SWITCH (4): The solution pump switch will illuminate when it is activated, and it will turn on the solution pump. The output pressure of this pump is adjustable through the unloader valve. Refer to the drawing below, and to the peration instructions GREEN, TW CIRCUIT INDICATR (5): This light will automatically turn on when you have plugged the two power cords into separate circuits. If this light does not turn on, try other outlets with one of the cords until the light does turn on. NTE: All systems in the machine will operate if this light does not turn on, but you may trip a circuit breaker in the wall. YUR MACHINE Solution Tank Access Switches Recovery Tank Lid Auto-fi ll Hose Connection Vacuum Hose Connection Recovery Tank Drain Pump-out Hose Connection Solution utput Power Cord Pigtails Pressure Adjustment Cap & Pressure Relief Valve (inside base compartment) 4

SET-UP & PERATIN 1. Before each use, inspect the machine, hoses, and cleaning tools for cleanliness and completeness. Make sure hoses are in good condition and the spray nozzle(s) is tight.. If not using the auto-dump feature, just make sure the brass cap is on the drain hose connector on the front of the base of the machine. If you choose to use the auto-dump feature, remove the brass cover on the hose connector on the front of base of the machine, attach a hose, and place the open end of the hose in a drain. Make sure the recovery tank drain gate is closed, and the lid is tight on the recovery tank. 3. If you choose not to use the auto-fill feature, just fill the tank with water and cleaning chemical. Follow chemical directions regarding dilution and mixing. Do not use harsh chemicals; they may damage seals in pumps and valves, and cause the pump to wear prematurely. If you choose to use the auto-fill feature, connect the fill hose to the auto-fill connector (located over the solution tank fill hole). Turn on the water source -- HIGH PRESSURE IS NT NECESSARY -- and allow the tank to fill with water. When using the auto-fill system, the auto-fill float will automatically turn on and turn off as the tank empties and then fills. NTE: Never put water with a temperature exceeding 130 F / 54 C in the solution tank 4. Pre-spray the area to be cleaned, with a pump-up sprayer, while the tank is filling. Follow chemical directions. 5. Plug in the two power cords. Do not connect both cords to the same outlet. The green, separate circuit locator light (1) on the switch plate should light up. If the locator light does not come on, check the circuit breaker box in the wall, and/or try different outlets until it does turn on. Although all systems in the machine may work correctly if you are not on two circuits, a circuit breaker in a wall panel may trip. If you make sure the green light is turned on, you will prevent tripped circuit breakers. 6. Prime the 100 psi pump: fill the solution tank with water, if not already done, and turn on the pump. You may notice a tone change in the sound of the pump (smoother, with less of a rattle). CAUTIN -- NEVER TURN N THE SLUTIN PUMP BEFRE CNNECTING YUR SLUTIN LINE T YUR MACHINE AND T YUR TL. If the pump builds pressure before you connect the hose and tool, you will not be able to connect them. 7. Use defoamer to prevent foam. 8. Attach the solution spray hose to the solution quick disconnect. Attach the vacuum hose to the hose barb on the front of the recovery tank. Connect the other ends of the hoses to the tool. 9. Turn on the vacuum () and turn on the dump pump (3). Begin spraying. 10. When the job is finished, turn off the water source. Vacuum the remaining solution from the solution tank into the recovery tank. 11. Run a few gallons of clean water through the system. Drain the recovery tank by opening the drain gate over a bucket or drain. Disconnect the hoses from the cleaning tool. 1. Unplug the power cords. Clean the machine and the tool. NTE: if the green, circuit locator light does not illuminate when the cords are plugged in, then both cords are on the same circuit. Try other outlets with one of the cords until you get the locator light to come on. CAUTIN: if the heat switch is turned on when both cords are on the same circuit, the breaker in the wall may trip. 5

AUT VACUUM SHUTFF: When the recovery tank is full, the ball float will shut-off the suction to prevent the machine from overflowing. NTE: the float may not work if there is foam in the tank. Always use defoamer to prevent overflow. AUT-FILL 1 peration: Attach a 3/4 garden hose to the auto-fill valve, and connect the other end of the hose to your water source. Make sure the float that hangs from the auto-fill valve into the tank is free of obstruction and can move freely. Turn the water supply on. The auto-fill float will automatically shut-off the flow of incoming water when the solution tank is nearly full, and it will allow the valve to open again once the water level has dropped to a predetermined level. AUT-DUMP 1 peration: Before each use: if necessary, unscrew the stainless steel filter at the bottom of the recovery tank and clean it. Also make sure the float in the recovery tank is clean. Attach a 3/4 garden hose to the dump pump outlet fitting on the back of the base of the machine. Run the other end of the hose into a drain. Turn N the dump pump switch (switch is located on the switch panel on the top of the machine). NTE: the dump pump is self-priming. You should see water start to flow within 30 seconds of the pump turning on. If water does not begin to flow, check the filter to see if it is plugged with debris. After each job: run clear water though the dump pump to wash out any chemical residue. Remove and clean the filters in the back of the recovery tank. Reinstall the filter once it is DANGER: D NT USE SLVENTS, R ANY CHEMICALS THAT MAY BE FLAMMABLE, EXPLSIVE, R CMBUSTIBLE. CAUTIN: always use a defoamer in the recovery tank to prevent water or foam from entering the vacuum motor. CAUTIN: Use care when handling hazardous chemicals. CAUTIN: Never put water hotter than 130 F / 54 C in the holding tank. CAUTIN: Never leave the 100 psi pump running when you are not actively using it. 6

7 39 40 40A 48 67 59 50 1 4 3 1 3 4 7 8 14 14A 15 16 17 18 5 9 3A 3 A 5 4 3 33 55 8 34 35 36 37 38 34B 53 53A 34A 58 49 54 56 45 41 4 43 44 46 1 69 57 47 61 6 63 64 60 ADVANTAGE 100 10V -16-010 65 8 8 1 13 4 11A 11A 10B 10 10A 11A 6 68 11 6A

ADVANTAGE-100 PART LIST 10V ITEM PART No DESCRIPTIN 1 903 Drain Gate 187B Gasket 3 187 -ring 4 185 Nut, 1-1/ 6 907 Hose Barb, vacuum inlet 7 1074 Gasket 8 086A Lid with Ring, 6 10 99B Ball Float, vac shut-off 10A 1154A Adapter, ABS trap 10B 1154 Adapter, ABS 11 9 Elbow, PVC, FPT 11A 1140 Elbow 1 156 Hose Clamp 13 430 Hose, vacuum, ID X 7 14 430A Hose, vacuum, ID X 14.5 14A 4404C Bar, vacuum hose hold-down 15 FP617 Switch plate, Advantage 16 163R Switch, push-button, N/FF 17 7 Green light 18 069B Filter, inlet 30 mesh 1 31 Washer, brass 1184 Adaptor, garden hose A 1310A Valve, water inlet 3 1533 Connector, hose adaptor 4 1534 Elbow, 1 90º 5 1571 Bushing, 1 x 1/ PVC 8 166 Hose clamp 9 1557A Screen, filter 3 175 Lid, Solution tank 3A 805 Chain, 8 33 TKC-6 Solution tank 34 946 Hose, pump inlet, 1/ ID X 15 34A 176 Elbow, 1/ ID, 90º 34B 177 Grommet, rubber 35 95 Hose, pump bypass, 3/8 ID X 13 ITEM PART No DESCRIPTIN 36 408G Vacuum, 3-stage 37 013 Gasket, vacuum 38 MA-6 Manifold, vacuum 39 30 Retainer, cord pigtail 40 155 Pigtail, power cord 40A 154 Power cord, 5 ft 41 801 Hinge pin 4 910-18.63 Axle rod, 18.63 43 09 Wheel, 1 inch 44 7A Axle cap 45 FP67D Base, complete 46 905 Castor 47 908 Latch 48 909A Catch, for latch 49 459 Louver, -1/ 50 45 Quick disconnect 5 FP69 Recovery tank 53 166 Pressure gauge 53A 19 Quick disconnect 54 050 Gasket, 78.5 55 1603 Strap, cord wrap 56 FP630 Hose assy, pump intake 57 37 Cap with chain, drain hose 58 067 Pump, dump 59 1546 Hose barb, two per bag 60 FP636 Motor, no pump 61 FP657 Pump, complete, no motor 6 FP63 Hose, unloader to outlet 6A FP656 Valve, pressure relief 63 FP633 Unloader valve assembly 64 FP631 Hose, pump to gauge 65 946 Hose, dump pump inlet, 3 67 4405A Relay, 5 AMP 68 FP619 Pre-filter bag 69 9A Nipple, s/s Miscellaneous parts and Assemblies FP618 Pump and motor, complete 1160K Pump rebuild kit, valves & o-rings 1160A Pump rebuild kit, plunger and seals FP655 Solution hose assembly, 5 ft -16-010 8

MAINTENANCE SCHEDULE DAILY WEEKLY THER MNTHLY YEARLY CLEAN ALL FILTERS X CHECK PWER CRD X FLUSH UT with DESCALER X REPLACE VAC MTR BRUSHES Around 1500 hours REPLACE PRESSURE REGULATR X r as needed REBUILD PUMP Around 1500 hours TRUBLE SHTING: IF THIS CCURS N SPRAY LW SUCTIN N SUCTIN LW HEAT N HEAT CHECK THIS Solution tank is empty. Clogged spray tip. Pump not running or not primed. Valve on wand not operating. Debris is plugging cleaning tool or vacuum hose. Drain hose is not completely closed. Vacuum tank lid is not closed or seal is damaged. No power to motor. Test the switch. Test the vacuum motor. Spraying too long. Try spraying for 8-10 seconds, or about three strokes. Heat exchanger needs to be flushed. Wrong tool being used. Too much water passing through. Longer hose or larger diameter hose, than standard. Heat is not turned on. No power in the wall outlet - check to see if the breaker has tripped. No power to the heat switch - check wiring for opens. No power out of heat switch, follow troubleshooting steps to isolate the problem. Call your distributor for additional help. 9

ADVANTAGE 100 NTES: 08-77-0573 800-57-798 FAX: 08-77-0577 Visit us on the web: www.usproducts.com 10