Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

Similar documents
Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

READ AND SAVE THESE INSTRUCTIONS

Owner and Maintenance Guide Models Equipped with K250 Blower

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Air-O Ultra Series Range Hoods

COPPER INSERT INSTALLATION INSTRUCTIONS, USE AND CARE GUIDE

Owner and Maintenance Guide for M Line Range Hoods with M600/M1200 Blowers

Installation Instructions Remote Blowers

Easy installation. EZ80N EZ Fit Ventilation Fan INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS. Table of Contents

Installation. Professional Built-in Hoods

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

Integrated Ventilation System

e Bath Fan with Light User s Guide

e Bath Fan with Light User s Guide

UseandCare & Installation Guide

Installation Instructions

breeze easytm model # F100-1W

Installation Instructions. Millennia Island (Ceiling Mount) Range Hoods. Models: DHI361, DHI421, DHI482 and DHI542

RSIF power venter USA CAN READ AND SAVE THESE INSTRUCTIONS! Installation and operation manual. Product information Chapters 1 + 2

WARNINGS: Must be followed carefully to avoid personal injury. IMPORTANT: Must be followed carefully to avoid damage or incorrect installation.

Easy installation in both new construction and retrofit RN80L RN110L READ AND SAVE THESE INSTRUCTIONS INSTALLATION GUIDE

Cooktop Chimney Ventilation Hoods

e Bath Fan with Light User s Guide

Installation Instructions Use and Care Guide Instructions d installation Mode d emploi et d entretien

ISLAND MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:

RSIF Power Venter USA CAN. Product Information. ... Chapters Mechanical Installation. ... Chapter 3. Electrical Installation. ...

Use, Care, and Installation Guide

e Heater/Exhaust Fan/Light User s Guide

Easy installation in both new construction and retrofit. READ AND SAVE THESE INSTRUCTIONS Installer: leave this guide with homeowner.

Installation Instructions Preference Wall Mount Range Hood

Installation Instructions

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Euro-style Range Hood ESH5200

UNDER CABINET RANGE HOOD

GE Monogram. Installation. Instructions. Component Cooktop System. Models ZEW145V ZGW124EN3 ZGW125EN3 ZEW155N ZEW166Y ZEW176Y

Pro Ventilation Hood Liners

UNDER CABINET RANGE HOOD. This manual is made with 100 % recycled paper.

READ AND SAVE THESE INSTRUCTIONS Page 1

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

READ AND SAVE THESE INSTRUCTIONS

Imperial Cal Products, Inc.

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Trade-Wind Professional Series Liners

Questions on Installation? Call: GECARES (US) or Visit our Web site at: (US) 4" DUCT CLAMPS (2) OR 4" SPRING CLAMPS (2)

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

CONTENTS WIRING DIAGRAM

RSIF Power Venter. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS

Imperial. Read Before Starting Installation!

Installation Instructions

Imperial. Cal. Products, Inc. Installation Instructions & Warranty Information. 425 Apollo Street Brea, CA

Installation Instructions

Downdraft Raised Vent

SAFETY AND INSTALLATION MANUAL MODEL 8100

Inspection Checklist Mechanical Rough in

Operating and Installation Instructions

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE 06E Series Model 06E Series Model RANGE HOOD LOCATION 1. The range hood must be installed just above the

INSTALLATION INSTRUCTIONS FOR DUCTED WHOLE HOUSE FANS

INSTALLATION INSTRUCTIONS ELECTRIC DRYER

Downdraft Ventilation

Installation Instructions Exhaust Fan With Light

APPUZO RANGE HOOD INSTALLATION

High Power Range Hood

Self-Cleaning Range Hoods

INSTALLATION INSTRUCTIONS

Self-Cleaning Range Hoods

READ AND SAVE THESE INSTRUCTIONS

CAUTION signals a situation where minor injury or product damage may occur if you do not follow instructions.

CONTENTS DESCRIPTION UNPACKING DIMENSIONS

BESF Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4

Questions? Call 800.GE.CARES ( ) or visit our Web site at: GEAppliances.com In Canada, call or visit


Operating Instructions & Parts Manual. Silent Low-Profile Ceiling Fans. Models 3DPE2A, 3DPE3A, 1UBH6B, 1UBH7B, 1UBH8A, 5AE68B, 5AE69A

RV30, RV36, RV46. 30, 36, 46 Wide, Raised Vent. Adjustable anchor legs. Front View

Bathroom Exhaust Fan/Fluorescent Light Combination

Glass Canopy Wall-Mount Hood

CLEANING & MAINTENANCE For performance, appearance, and health reasons, clean filter, fan and grease-laden surfaces. Use only a clean cloth and mild d

INSTALLATION INSTRUCTIONS Trade-Wind In-Line Blower / Ventilators

ERV3015, ERV3615. Renaissance 30, 36 Wide, High Extension Slim Raised Vents. Top cap with vent down

Questions? Call 800.GE.CARES ( ) or visit our Web site at: GEAppliances.com In Canada, call or visit

READ AND SAVE THESE INSTRUCTIONS WARNING! TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS OBSERVE THE FOLLOWING:

TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS SAFETY PROCEDURES PRECAUTIONS FOR RECEIVING AND STORING HOOD

WALL MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:

XOE30 XOE36 READ AND SAVE THE INSTRUCTIONS FOR RESIDENTIAL COOKING ONLY

CHIMNEYS AND VENTS CHAPTER 8

Installation Instructions

Dryer. User manual DV22K6800** DV22K A-00_EN (US)_ indd :15:41

Installation Instructions DAR 1150, DAR 1220 DAR 1230, DAR 1250

! INTENDED FOR DOMESTIC COOKING ONLY!

Installation Instructions

Bathroom Exhaust Fan/Fluorescent Light Combination

2012 INTERNATIONAL FUEL GAS CODE VENTS

BESF Box Ventilator. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS

Microwave Oven. IMPORTANT SAFETY INSTRUCTION Never operate the oven when it is empty or without the glass turntable.

Installation Instructions

Smart Choice Electric Dryer Installation Kit

Installation Instructions

2015 MECHANICAL CODE REQUIREMENTS

INSTALLATION INSTRUCTIONS

Transcription:

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS UNDER CABINET HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: A. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction. Switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally during installation. B. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. C. Ducted fans must always be vented to the outdoors. D. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and local code authorities. WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK Page 1 C U L R US

Ducting Do s and Don ts NEVER restrict the duct size. The single blower unit (B100) requires round duct or equivalent (28 square inches), and the dual blower unit (B200) requires round duct or equivalent (50 square inches). When combining ducts together, the square inch area must reflect the total square inch area of the ducts being combined. Using Vent-A-Hood transitions (back page) will ensure proper efficiency. Blower Duct Size Sq. Inch Area Vent-A-Hood Transition Single (B100) round or equivalent 2 N/A Dual (B200) round or equivalent 50 N/A Single and Dual (B100 & B200) round or equivalent 79 VP562 (Optional) Two Dual (Two B200s) round or equivalent 113 VP563 (Optional) Do not use flexible or corrugated duct. This type of duct will restrict airflow and reduce performance. Only use smooth, galvanized, metal duct. Observe local codes regarding special duct requirements and placement of duct against combustibles. Make the duct run as short and as straight as possible with as few turns as possible. Avoid sharp-angled turns. Instead, use smooth, gradual turns such as adjustable elbows or 45 degree angled turns. For duct runs over 20 feet, increase the duct diameter by one inch for every ten feet of duct. A 90 degree elbow is equal to 5 feet of duct. Using Vent-A-Hood roof jacks or wall louvers (back page) will ensure proper efficiency. Airflow must not be restricted at the end of the duct run. Do not use screen wire or spring-loaded doors on wall louvers or roof jacks. Do not terminate venting into an attic or chimney. Where possible, seal joints with duct tape. The hood must be ducted to the outdoors without restrictions. YES Smooth Duct Smooth Gradual Turn Proper Combining of Two Ducts NO Flexible Duct Sharp Angled Turns Improper Combining of Two Ducts Page 2

Installation Details 1) Read all instructions thoroughly before beginning installation. Note: These instructions apply to standard hoods only. Custom hoods may require additional specification consideration. 2) When installing a 9 tall under cabinet hood, it is recommended that the bottom edge of the hood be located no more than 24-27 above the cooking surface. For the SL6/SLH6, the recommended mounting height is no more than 21-24 above the cooking surface. Exceeding recommended mounting height may compromise performance. Soffit Soffit Cabinets Cabinets 9 8 Ceiling 24-27 8 Ceiling 21-24 3 3 9 Tall Hood SL6/SLH6 3) Inspect the underside of the cabinet for a flush mounting surface. If the underside is recessed, install wood strips to provide a flush surface for the hood mounting screws to engage. 4) Cut hole(s) in the bottom of the cabinet to allow for duct(s) and electrical to pass through. Consult the connection diagrams (on next page) for further details on exhaust outlet and electrical placement. 5) IF THE HOOD IS TO BE BACK VENTED, PROCEED DIRECTLY TO STEP 6. Install the duct(s) from the outside of the home down to the location of the exhaust outlet(s) on the top of the hood allowing room for the transition (if applicable). If a transition is used, install duct down to the location of the transition outlet plus 1. This will allow the transition to engage 1 inside of duct. Consult the connection diagrams (on next page) for further details on exhaust outlet placement. Use duct tape to seal all joints. A complete listing of available Vent-A-Hood ducting materials is provided on the back page of this instruction sheet. Transition heights are as follows: Single Blower (B100): Dual Blower (B200): Single and Dual Blower (B100 & B200): Two Dual Blowers (Two B200s): round duct will connect directly to the top of the liner. round duct will connect directly to the top of the liner. round duct will connect directly to the top of the hood; round will connect directly to the top of the hood. Optional round combination transition (VP562, sold separately) is 17 1/2 tall. Two rounds connect directly to the top of the hood. Optional round combination transition (VP563, sold separately) is 16 1/2 tall. Page 3

Installation Details Continued Connection Diagrams 30-4 Widths Centerline Of Hood 300 B100 Single Blower 600 B200 Dual Blower Connection Diagram 42-4 Widths Connection Diagram 4 Width 900 B200 Dual & B100 Single Blower 1200 Double B200 Dual Blowers 6) Remove the hood from its packaging and place the back of the hood on the floor or countertop in front of the cabinet where it will hang. 7) Remove the blower shield(s) (A) by loosening the two brass screws on the bottom of the shield(s). Gently close the back draft damper(s) from the top side of the hood. To remove the blower housing(s), unsnap the suitcase latches (B) (one on each side of the housing). The housing(s) should be pulled forward and gently tipped to clear the blower wheel(s) and then out of the hood. 7) Remove the three screws retaining the blower motor(s). Unplug and remove the motor(s), taking care not to damage the blower wheel(s). It is not necessary to remove the blower wheel from the motor. Warning: Make sure power is off and locked at the service disconnecting means on the service panel during installation. Page 4

B100 Single B200 Dual Model Installation Details Continued 9) Install an appropriate 1/2 UL listed electrical wire clamp through each motor box electrical opening on top of the hood. Install electrical wiring from the service panel to the hood location for each motor box. Consult the connection diagrams (on previous page) for further details on electrical placement. Volts Amps* RPM 115 115 1.7 3.4 1550 1550 SP@0.0 300 600 Equivalent 450 900 # SP@0.1 286 572 SP@0.2 270 540 SP@0.3 240 480 Minimum Round Duct Size (or equivalent) (or equivalent) * Note: Add 2.5 amps for each warming light and 0.5 amp for each halogen light. TM TM # Because the Magic Lung uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung blower can handle cooking equipment with higher cubic feet per minute () requirements and can deliver equivalent much more efficiently TM than other than other filtration systems. When comparing the Magic Lung with other blower units made by other manufacturers, use the Equivalent. 10) Insert the electrical wire from the service panel into the electrical wire clamp on each motor box. Tighten the wire clamp(s). 11) FOR BACK VENTING APPLICATIONS ONLY. IF NOT BACK VENTING, SKIP STEP 12. PROCEED DIRECTLY TO STEP 13. Note: Wall studs may interfere with back venting installations. Additional framing may be required. It is necessary to cut duct access hole(s) in the wall prior to installing the hood. To accomplish this, place the appropriate elbow(s) on the bottom of the cabinet in line with the duct hole(s) cut in Step 4. On the wall, trace around the elbow(s). Be sure to account for the wood thickness of the bottom of the cabinet when tracing duct access holes. Remove the elbow(s) from the cabinet. Cut around the outside of the traced line(s), avoiding wall studs. Install the duct from the outside of the home to the opening in the wall. Use duct tape to seal joints. 12) Pull the electrical wire slack into the cabinet while raising the hood into position. Using the four screws provided, attach the hood to the bottom of the cabinet. Place the appropriate elbow(s) on the top of the hood. Elbow(s) should be placed with the non-crimped end(s) on the inside the collar(s) of the exhaust outlet(s). Use duct tape to seal all joints. Retract the electrical wire slack into the wall cavity or attic space. SKIP STEPS 13 AND 14. PROCEED DIRECTLY TO STEP 15. 13) FOR DIRECT DUCT CONNECTIONS ONLY. IF USING TRANSITIONS PROCEED DIRECTLY TO STEP 14. Pull the electrical wire slack into the cabinet while raising the hood into position and aligning the duct(s). The duct(s) should connect together as the hood is located in place. Note: The duct work must fit inside the exhaust collar(s). Using the four screws provided, attach the hood to the bottom of the cabinet. Use duct tape to seal all joints. Retract the electrical wire slack into the wall cavity or attic space. SKIP STEP 14. PROCEED DIRECTLY TO STEP 15. 14) FOR TRANSITION CONNECTIONS ONLY. Pull the electrical wire slack into the cabinet while raising the hood into position. Using the four screws provided, attach the hood to the bottom of the cabinet. Connect the appropriate transition(s) between the exhaust collar on the top of the hood and the duct work overhead. Note: The bottom of the transition(s) should fit inside the exhaust collar(s) on the top of the hood and on the inside of the duct work overhead. Use duct tape to seal all joints. Retract the electrical wire slack into the wall cavity or attic space. 15) From inside the hood, using UL listed wire nuts, attach the neutral wire(s) to the white lead(s), the hot wire(s) to the black lead(s), and the ground wire(s) to the green lead(s) inside the motor box(es). Warning: Do not operate hood without proper ground connection. 16) Plug the motor(s) into the hood and reinstall the blower motor(s) using the three retaining screws that were previously removed in Step 8. 17) Replace the blower housing(s) and the blower shield(s). Make sure that the damper(s) open and close smoothly. 18) Refer to the Owner Maintenance Guide Operating Instructions for proper hood operation. Test all blower and light functions to ensure they are operating properly. Square Inches 28 50 Page 5

VENTING ACCESSORIES 8 5/ 1 1/2 FLANGE 1 1/2 FLANGE 13 1 1/2 FLANGE 2 FLANGE,7, 13 VP526 RD VP527 7 RD VP528 RD VP538 x8 1/2 VP554 RD VP555 RD VP560 x LOW PROFILE ROOF JACK (MAXIMUM 4/12 PITCH) LOW PROFILE ROOF JACK (MAXIMUM 4/12 PITCH) ADJUSTABLE ELBOW,7, ROUND BACK/SIDE VENT ELBOW 8 1/2 16 3/4 VP539 VP540 7 VP541 16 3/4 6 1/2 22 1/2 VP552 VP553 20 3/4 10 1/2 VP513 VP514 7 VP515 ROUND VP561 - x 8 1/2 BACK VENT ELBOW 4 1/4 14 VP559 X MULTI-BLOWER TRANSITION RD (VP562) RD (VP563) RD RD VP562 VP563 RD (VP562) RD (VP563) 17 1/2 VP562 16 1/2 VP563 Y TRANSITION, 1 VP517 x - VP518 x - VP551 x - 10 TO 7 TRANSITION 7 7 1/2 VP521 x - 7 OFFSET KIT-ROUND OFFSET KIT-RECTANGLE STANDARD ISLAND 7 TRANSITION CLUSTER BLOWER TRANSITION 10 1/2 9 11 1/4 VP529 TO 7 VP550 -x VP565 5 RD VP564 RD 18 1/2 OFFSET L & R TRANSITION FOR ISLAND BLOWERS SIDE VENT TRANSITION L & R FOR ISLAND HOODS 19 ROUND COLLAR, 2 MORE THAN HOLE DIA. COLLAR, SQUARE 9 5 VP542 TOP LEFT ISLAND VP543 TOP RIGHT ISLAND VP544 LEFT SIDE VP545 RIGHT SIDE 5 2 MORE THAN HOLE DIA. VP533 VP535 8 1/2 11 1/2 VP537 6 x 8 1/2 ROUND DUCT RECTANGLE DUCT RECTANGLE DUCT,7, VP500 VP501 7 VP502 3 30 VP504 x VP505 x VP506 x 24 8 1/2 VP507 x 8 1/2 Page 6