POUNDS PER FOOT MINIMUM WALL (IN.) 4" 4.80".192" 1.87 lbs..267" 2.55 lbs..343" 3.22 lbs. 6" 6.90".276" 3.90 lbs..383" 5.29 lbs..493" 6.70 lbs.

Similar documents
Review of Residential Fire Sprinkler Systems for One- and Two-Family Dwellings

A. Section includes wet-pipe sprinkler system, system design, installation, and certification.

Page 1 of 19

ANTEC SUSTAINABILITY OF PVC (VINYL) PIPE: A COMPREHENSIVE ENVIRONMENTAL REVIEW. May 9, 2017

DIVISION 21: FIRE SUPPRESSION SYSTEMS SECTION Fire Protection Systems Protecting Cold Storage and Unheated Warehouses

(Alarm Valve) & ' ( ()& * +,, & +-,. /0-

Internal Use Only INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS IAPMO GUIDE CRITERIA FOR

SECTION AUTOMATIC SPRINKLER PIPING

SECTION FIRE-RATED GLASS AND FRAME

1.2 CODES AND REGULATIONS A. Sprinkler system design, equipment, materials, devices, and installation shall conform to the following:

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

CONTRACT FOR USE OF FIRE PROTECTION SYSTEM

SOUTH AFRICAN NATIONAL STANDARD

UMC El Paso Far East Clinic and Neighborhood Healthcare Center West Issue for Construction Page Project No and April 13, 2015

Industrial Fiberglass Specialties, Inc. 521 Kiser Street Dayton, OH Tel: Fax:

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

1.1 Refer to Section for General Mechanical Requirements. 1.3 Refer to Section for Pipe and Equipment Identification Requirements.

BlazeMaster Fire Sprinkler Systems

MECHANICAL VENTING VERSATILITY

FIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University.

Duraplus ABS for Secondary Loop Refrigeration Control Systems

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

Western Michigan University Facilities Management Engineering Division

PART 1 - GENERAL SECTION FIRE PROTECTION BASIC MATERIALS AND METHODS

Grooved Piping System The only system that provides the option of rigidity or flexibility

Series 759 FireLock Alarm Check Valve

Discontinued Product

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING SuperClear 45-HS (patent pending)

Butterfly Valve Grooved end & Wafer Type 175Psi and 300Psi 2-1/2" - 8" (DN65 - DN200)

DIVISION 21 - FIRE SUPPRESSION

A. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup.

SECTION WET-PIPE SPRINKLER SYSTEMS

COBB COUNTY SCHOOLS /S&A % BID DOCUMENTS 2/18/11 SECTION SPRINKLER SYSTEM

RM with INNOVATOR Doors

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Impermeable Liner

3 diameter specification sheet

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code

IMPORT PRICE LIST. version: IMP-JRPL EFFECTIVE: JANUARY 1, 2018 (SUPERSEDES ALL PREVIOUS PRICING) EFFECTIVE JANUARY 1, 2018

Model DDX Deluge Valve

Fire Pump Specification

INTERNATIONAL STANDARD

ESFR PENDENT SPRINKLER VK500 (K14.0) TECHNICAL DATA

esfr pendent sprinkler vk510 (k25.2)

TECHNICAL INFORMATION WEIGHTS & DIMENSIONS

Union County Vocational - Technical Schools Scotch Plains, New Jersey

PLUMBING FIXTURES CHAPTER 27

Model JL-14 (SIN RA1812) K14.0 (200 metric) Early Suppression Fast Response Sprinkler

TABLE OF CONTENTS DIVISION 21- FIRE SUPPRESSION PAGES SECTION WATER BASED FIRE PROTECTION SYSTEMS... 5

DOMESTIC WATER PACKAGED BOOSTER PUMPS

Lee s Summit West High School Boiler #3 Replacement SECTION CONDENSING BOILERS

ESFR PENDENT SPRINKLER VK510 (K25.2) TECHNICAL DATA

Commercial Gas Water Heaters

Freedom Line RFM. Certified. with INNOVATOR Doors. Medium Temperature Technical Data Sheet P/N _B NSF. Freedom Line merchandisers are top mount

Fire Sprinkler System Reliability, Arguments Regarding the Use of CPVC. SUPDET 2013 Orlando, Florida February 28, 2013

Elements Headwall System (P2008A)

DIVISION 21 - FIRE SUPPRESSION

Residential Fire Protection Sprinklers & Systems

INTERNATIONAL STANDARD

C. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant.

Additional Bulletins applicable to all F1RES LL Sprinklers Wall Wetting - Bulletin 007 Design and Installation - Bulletin 140

SECTION ELECTRIC-DRIVEN, FIRE PUMPS

Appendix I. Geothermal Heat Pump Design and Installation Standards October 1, 2001

Commercial Gas Water Heaters

Your roof is waiting for it PRODUCT CATALOGUE Podsufitki

NFPA 54 UPDATE. Paul Cabot American Gas Association

Freedom Line RFMN. Certified. with INNOVATOR Doors Medium Temperature Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount

INFACT CORPORATION WATERWORKS PRODUCTS FLEX REDUCER SPECIFICATION S TOLL FREE:

SECTION PLUMBING PIPING

Leading. Click to edit Master subtitle style. 3M Fire Protection Products Awareness & Introduction to 3M Fire Protection Products

I-VICFLEX.AB4. Victaulic VicFlex Style AB4 Sprinkler Fitting for Hat Furring Channel Ceiling Systems WARNING INSTALLATION INSTRUCTIONS

Flame Retardant Polyethylene Tubing

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (600 VOLTS AND BELOW)

Pneumatic Tubing POLYTUBING O.D. 5/32"

IECEx Certificate of Conformity

UNIVERSITY OF MISSOURI Fire Protection System Design 2016 Q1

SECTION ELECTRICAL GENERAL PROVISIONS

RL with INNOVATOR II No Heat Doors

Manufactured specifically for Acid Waste systems. NSF certified to meet all performance standard of ASSE 1051

Radiant Heating Installation Notes

SECTION GYPSUM PLASTER

UC Santa Cruz Campus Design Guide. Includes the following sections: None DESIGN REQUIREMENTS

Read Only Copy Not For Distribution. Chapter 19. Referenced Standards 19.1 REFERENCED STANDARDS 19.2 STANDARDS ORGANIZATIONS

Freedom Line RFMNS. Certified. with INNOVATOR Doors. Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount.

Flow Control for Fire Protection

TECHNICAL DATA. * Refer the Approval Chart on page 120c and Design Criteria on page 120d for culus and FM approval requirements that must be followed.

PVC Venting Addendum. RIVA Plus WALL HUNG GAS BOILER FOR CENTRAL HEATING SUPPLY

CPVC solvent cements for CPVC pipes and fittings

INTERNATIONAL STANDARD

Model ESFR K-factor Pendent Sprinkler Early Suppression, Fast Response General Description. Sprinkler Identification Number (SIN)

Flow Control for Fire Protection

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

esfr pendent sprinkler vk510 (k25.2)

Transfer Switch Features

SELF-PRIMING CENTRIFUGAL PUMPS BMLS-M & BMLS-H

Tri-Max Aerator GPM. Three flow rate options Patented FlexFlo technology Dual-thread brass connection

POTABLE PIPING SYSTEM

SECTION FIRE PROTECTION

WATERSIDE BUILDING GROUP E4

specifications the many advantages of bondstrand gre pipe systems

WET-PIPE SPRINKLER SYSTEMS

Transcription:

u ANSI/AWWA C900 WATER DISTRIBUTION PIPE Pipe Specifications (4" - 12") Northern Pipe Products PVC ANSI/AWWA C900 PVC Pressure Pipe is manufactured from compounds conforming to cell classification of 12454 as defined in ASTM D1784. The pipe meets the requirements of the ANSI/AWWA C900 standard specification for polyvinyl chloride water distribution pipe. The integral bell joint system meets the requirements of ASTM D3139 and utilizes an elastomeric seal meeting the specification defined in ASTM F477. Northern Pipe Products ANSI/AWWA C900 pressure pipe for potable water carries: NSF Standard 14 and NSF Standard 61 listings (marked "NSF-PW-G") Certification under NSF/ANSI 327 Annex G "lead-free" (marked "NSF-PW-G") Underwriters Laboratories Inc. Standard 1285 mark of acceptance Canadian Standards Association Standard B137.3 mark of acceptance ANSI/AWWA C900 (4" - 12") DR-18 and DR-14 distribution pipe carries the Factory Mutual Research Water Distribution Pipe for Underground Fire Protection Service mark of acceptance. The pipe is furnished in 20 laying lengths. u ANSI/AWWA C900 Cell Classification 12454 PIPE OUTSIDE DR-25 (165 PSI) DR-18 (235 PSI) DR-14 (305 PSI) 4" 4.80".192" 1.87 lbs..267" 2.55 lbs..343" 3.22 lbs. 6" 6.90".276" 3.90 lbs..383" 5.29 lbs..493" 6.70 lbs. 8" 9.05".362" 6.69 lbs..503" 9.15 lbs..646" 11.55 lbs. 10" 11.10".444" 10.11 lbs..617" 13.82 lbs..793" 17.46 lbs. 12" 13.20".528" 14.32 lbs..733" 19.56 lbs..943" 24.75 lbs.

u ANSI/AWWA C900 WATER DISTRIBUTION PIPE Gasketed Joint Specifications (4" - 12") Northern Pipe Products PVC gasketed ANSI/AWWA C900 PVC potable water distribution pipe is manufactured with gasketed joints conforming to the specifications of ASTM D3139. The gaskets are manufactured to conform to the requirements of ASTM F477. Northern Pipe Products employs the Rieber Gasket System. The Rieber joining system is a factory made locked-in flexible elastomeric seal. The gasket is installed in the bell race during the manufacture of the joint. It should not be removed for any reason, as destruction of the joint will occur. u LOCKED-IN GASKET JOINT A B C E D A. Gasket Groove (Race) Outside Diameter B. Lip Length C. Gasket Groove (Race) Length D. Overall Joint E. Spigot Insertion Depth DIMENSIONS (A) (RACE) OUTSIDE (B) LIP LENGTH (C) (RACE) LENGTH (D) OVERALL JOINT (E) SPIGOT INSERTION DEPTH 4" 6.50" 1.500" 1.125" 6.000" 5.000" 6" 9.00" 1.750" 1.250" 6.500" 5.500" 8" 11.50" 2.000" 1.500" 7.500" 6.500" 10" 14.00" 2.500" 1.750" 8.750" 7.750" 12" 16.50" 3.000" 1.875" 9.750" 8.750"

u ANSI/AWWA C900 WATER TRANSMISSION PIPE Pipe Specifications (14" - 24") (Previously C905) Northern Pipe Products PVC ANSI/AWWA C900 PVC Water Transmission Pipe is manufactured from compounds conforming to cell classification of 12454 as defined in ASTM D1784. The pipe meets the requirements of the ANSI/AWWA C900 standard specification for polyvinyl chloride water transmission pipe. The integral bell joint system meets the requirements of ASTM D3139 and utilizes an elastomeric seal meeting the specification defined in ASTM F477. Northern Pipe Products ANSI/AWWA C900 pressure pipe for potable water carries: NSF Standard 14 and NSF Standard 61 listings (marked "NSF-PW-G") Certification under NSF/ANSI 327 Annex G "lead-free" (marked "NSF-PW-G") Underwriters Laboratories Inc. Standard 1285 mark of acceptance Canadian Standards Association Standard B137.3 mark of acceptance 14 and 16 diameter DR-25 and DR-18 transmission pipe carries the Factory Mutual Research Water Distribution Pipe for Underground Fire Protection Service mark of acceptance. The pipe is furnished in 20 laying lengths. u ANSI/AWWA C900 Cell Classification 12454 PIPE OUTSIDE DR-25 (165 PSI) DR-21 (200 PSI) DR-18 (235 PSI) DR-14 (305 PSI) 14" 15.30".612" 19.35 lbs..729" 22.90 lbs..850" 26.50 lbs. 1.093" 33.70 lbs. 16" 17.40".696" 25.20 lbs..829" 29.70 lbs..967" 34.50 lbs. 1.243" 43.70 lbs. 18" 19.50".780" 31.65 lbs..929" 37.50 lbs. 1.083" 43.40 lbs. 1.393" 54.90 lbs. 20" 21.60".864" 39.00 lbs. 1.029" 46.10 lbs. 1.200" 53.50 lbs. 1.543" 67.65 lbs. 24" 25.80" 1.032" 56.00 lbs. 1.229" 65.60 lbs. 1.433" 76.50 lbs. N/A N/A

u ANSI/AWWA C900 WATER TRANSMISSION PIPE Gasketed Joint Specifications (14" - 24") Northern Pipe Products PVC gasketed ANSI/AWWA C900 PVC water transmission pipe is manufactured with gasketed joints conforming to the specifications of ASTM D3139. The rubber gaskets are manufactured to conform to the requirements of ASTM F477. Northern Pipe Products employs the Rieber Gasket System. The Rieber joining system is a factory made locked-in flexible elastomeric seal. The gasket is installed in the bell race during the manufacture of the joint. It should not be removed for any reason, as destruction of the joint will occur. u LOCKED-IN GASKET JOINT A B C E D A. Gasket Groove (Race) Outside Diameter B. Lip Length C. Gasket Groove (Race) Length D. Overall Joint E. Spigot Insertion Depth DIMENSIONS (A) (RACE) OUTSIDE (B) LIP LENGTH (C) (RACE) LENGTH (D) OVERALL JOINT (E) SPIGOT INSERTION DEPTH 14" 18.25" 3.00" 2.00" 10.00" 9.00" 16" 20.50" 3.00" 2.25" 10.00" 9.00" 18" 23.25" 3.50" 2.44" 11.25" 10.25" 20" 25.60" 3.50" 2.70" 11.25" 10.25" 24" 30.25" 3.50" 3.00" 11.25" 10.25"

Truckload Data u C900 Truckload Data PIPE SIZE PIPE OUTSIDE FEET PER PALLET PIECES PER PALLET FEET PER TRUCKLOAD 4" 4.80" 580' 29 pcs. 16,240' 6" 6.90" 560' 28 pcs. 6,720' 8" 9.05" 200' 10 pcs. 4,000' 10" 11.10" 240' 12 pcs. 2,880' 12" 13.20" 120'/160' 6 pcs./8 pcs. 1,960' 14" 15.30" 120' 6 pcs. 1,440' 16" 17.40" 40'/60' 2 pcs./3 pcs. 1,000' 18" 19.50" 60'/80' 3 pcs./4 pcs. 800' 20" 21.60" 80' 4 pcs. 640' 24" 25.80" 60' 3 pcs. 360'