HX-40/40AM/ 40DAM. High Mount Outdoor Detector

Similar documents
HX-80NRAM. High Mount Outdoor Detector

REDWALL-V series REDWALL-V INSTALLATION AND MAINTENANCE NOTES. Synthesized Intelligent PIR FEATURES INSTALLATION HINTS PARTS IDENTIFICATION

This symbol indicates prohibition. The specific prohibited action is provided in and/or around the figure.

No INSTALLATION INSTRUCTIONS m (7.6-3 ft.) Far area mirror Masking plate for far area Fixing rubber form

AX-100TFR/AX-200 TFR INTRODUCTION 1-1 BEFORE YOUR OPERATION BATTERY OPERATED PHOTOELECTRIC DETECTOR. Warning FEATURES. Caution. Warning.

FEATURES OPTION 1.DESCRIPTION AND OPERATION 2.DETECTION AREA PASSIVE INFRARED AND MICROWAVE COMBINATION DETECTOR. No.

other ambient light sources. Before installation, make sure to read this instruction manual carefully for safe and effective product operation.

Description. Optex Incorporated

INSTALLATION INSTRUCTIONS. This model is UL Listed product. The comment with *UL-Number are UL s requirements and information for using this product.

RLS-3060SH REDSCAN ULTIMATE

RLS-3060SH REDSCAN ULTIMATE

5800-OD Wireless Outdoor Motion Sensor Installation Instructions

FTN-RRHW/FTN-RRIX FTN-RR2G/FTN-RRDS

Installation Instructions

LC-151 Dual-Tech Motion Sensor (Single PIR & Microwave) with adjustable Pet Immunity INSTALLATION INSTRUCTIONS & USER MANUAL P/N: ver.

DUAL ZONE OUTDOOR PIR MS-12TE & MS-12FE

Microwave/PIR Intrusion Detector with POPIT Interface ZX970

RCR-REX Request-to-Exit Dual Technology Motion Sensor Installation Guide

Installation Instructions

REDWALL-V series REDWALL-V INSTALLATION AND MAINTENANCE NOTES. Synthesized Intelligent PIR ENGLISH FEATURES FRANÇAIS DEUTSCH INSTALLATION HINTS

D-TECT 3 IP. GJD260 IP Motion Detector

International Customer Edition Date: June 2014

English. Italiano. Português. Françias. Español

alarm shop Outdoor PIR + MW Detector with Double Dual Mirror Optics INSTALLATION INSTRUCTIONS & USER MANUAL ELECTRONIC ENGINEERING LTD.

VX-402, VX-402REC CONTENTS FEATURES

D-TECT Dual Tech. GJD360 Triple Technology External Detector

DS9370-BEL. Installation Instructions TriTech Ceiling Mount PIR/Microwave Intrusion Detector

LUX Hardwired - Installation Notes

WIRELESS OUTDOOR DUAL TECHNOLOGY MOTION DETECTOR AOD-200

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

D-Tect 2 GJD300 Quad PIR Movement Detector

Intrusion Outdoor Protection Perimeter

DT8050A DUAL TEC Motion Sensor with Anti-Mask - Installation Instructions

DT8016AF4 / DT8016AF5 DUAL TEC Motion Sensor with Anti-Mask Installation Instructions

Advanced DIGITAL Wired PIR Motion Detector

D-TECT 2 IP. GJD230 IP Motion Detector

High Mount. Low Mount. High security wired tri-technology external detectors with anti-masking

Immunity. P/N: ver.b

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

ISC-PDL1-W18G-H. Installation Instructions Professional Series Dual Detector

General Description. Industrial LuNAR DT AM Grade 3 Features

XHS1-TY / MP-841 ZigBee Home Automation 1.2 Wireless Digital Pet Immune PIR Detector

Movement Detector GJD 300

DUAL TECHNOLOGY SENSOR (PIR + Microwave) Outdoor use INSTALLATION MANUAL

1125 PIR Motion Detector

Installation Manual Premier Elite Orbit QD/DT INS483-2

DT900 Series Sensors TECHNOLOGY FOR LARGE COMMERCIAL AND INDUSTRIAL APPLICATIONS. Impressive Performance, Impressive Coverage

Premier External TD. Installation Manual INS352-3

English version. Alarm systems Terms and definitions

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

Ceiling Microwave presence/absence detector 12-24V AC/DC

Extended Range DUAL TEC Motion Sensor

DD205RF/TX Detector Installation Sheet

STANDARD FEATURES SPECIFICATIONS

AX-70TN, AX-130TN, AX-200TN AX-100TF, AX-200TF

DS160/161 Request To Exit PIR sensors Installation Instructions

Intrusion. Outdoor protection perimeter

This document is a preview generated by EVS

DHR3. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer. INSTALLATION INSTRUCTIONS

MWS3A-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features

FF-SR Series. FF-SR25933 Two-hand Safety Control Module FF-SR25933

DATA CENTER SECURITY. March 2017 Anton Panaitescu

Photobeam 5000 ISC-FPB1-W60QS, ISC-FPB1-W120QS, ISC-FPB1-W200QS. en Installation and Operation Guide

PHOTOELECTRIC BEAM SENSOR PR-11BE : OUTDOOR 3.3 to 36ft. (1 to 11m) : INDOOR 3.3 to 49ft. (1 to 15m)

ALARM SYSTEMS - INTRUSION AND

design line performance line Guardall DesignLine & PerformanceLine detector series 2015 Peace of mind

PRODUCT INFORMATION HISIC450 OVERHEIGHT DETECTORS RELIABLE OVERHEIGHT DETECTION OF VEHICLES. Traffic sensors

Long-Range Barrier Sensors

DS160/DS161 Request To Exit PIR sensors Installation Instructions

FLAME SENSOR FS-2000E

Commercial Series TriTech Motion Detector. Reference Guide

DI601AM Outdoor PIR/AM Detector Installation Sheet

Section 1: General Description. Section 2: Features. Section 3: Operation. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions.

Commercial Series TriTech+ Motion Detector with Anti-mask

CM-RQE70 PIR REQUEST TO EXIT DETECTOR

DH400. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer.

Photobeam 5000 ISC-FPB1-W60QF, ISC-FPB1-W120QF, ISC-FPB1-W200QF. en Installation and Operation Guide

Dual Technology Wall Switch Occupancy Sensor. Manual & Specification

>WIRELESS> ALARM SYSTEM CR200

Installation, Operation, and Maintenance Manual. i-alert 2 Equipment Health Monitor

CM-RQE70A PIR REQUEST TO EXIT DETECTOR

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

Viewguard Motion detctors PIR and DUAL detectors

M O T I O N DETECTORS. The Paradox series of motion detectors. combines advanced features and patented. technologies to provide a high level of

1126 Series Ceiling Mount PIR Motion Detector

English. Series. Installation and Use Manual

SP-1000X. Panic Device Power Controller Installation Guide. Rev

This document is a preview generated by EVS

RILEVATORI DI MOVIMENTO DA INTERNO serie unum

MWS3 Ceiling Mount Microwave Occupancy Detector

NetworX NX-548E Receiver Installation Instructions

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

PACKAGING - REQUIREMENTS FOR PACKAGING RECOVERABLE BY MATERIAL RECYCLING STANDARD I.S. EN 13430:2004. Price Code

This document is a preview generated by EVS

Passive Infrared (PIR) Wall Switch Occupancy Sensor Dual Circuit

External Wireless Sounder

Accuracy counts! Sensors with analog output

INFRARED PERIMETRAL BARRIER DOUBLE BEAMS

Digital Thermometer with Ice Alert and Clock

PHOTOELECTRIC DETECTOR

Transcription:

HX-40 PIRs standard model HX-40AM HX-40 with anti-masking HX-40DAM HX-40AM with micro-wave 3.0 m high mount detection area (.0 m) Unique pyro element Intelligent AND logic High Mount Outdoor Detector HX-40/40AM/ 40DAM Dual signal processing logic Vegetation sway analysis logic Ideal detection area setting Digital anti-masking (AM/DAM model only) Microwave range selector (DAM model only) NO.59-50-3 INSTALLATION INSTRUCTIONS N9 CONTENTS INSTALLATION PRECAUTIONS... - BEFORE INSTALLATION... - PARTS IDENTIFICATION...3-3 KNOCKOUTS...4-4 DETECTION AREA...5-5 DETERMINATION OF PIR DETECTION LENGTH...5 INSTALLATION...6 - MOUNTING WITH BRACKET...6 - ADJUSTING THE VERTICAL ANGLE...8-3 MOUNTING WITHOUT BRACKET...9-4 WIRING...0-5 WALL TAMPER (OPTION)... 3 WALK TEST... 4 SETTING...3 5 AREA ADJUSTMENT...6 6 LED INDICATION...7 7 SPECIFICATIONS...8 7- SPECIFICATIONS...8 7- DIMENSIONS...9 - -

INSTALLATION PRECAUTIONS - BEFORE INSTALLATION Warning Failure to follow the instructions provided with this indication and improper handling may cause death or serious injury. Caution Failure to follow the instructions provided with this indication and improper handling may cause injury and/or property damage. The check mark indicates recommendation. The nix sign indicates prohibition. Warning Warning Caution Do not repair or modify product Mounting height Keep product away from water Mount the unit securely Keep the detector parallel to the ground..5 m 3.0 m (8'" 9'0") Parallel Tilt Consider the direction a person is approaching from, as well as the detection area. Install the detector in a place where it is free from false alarm factors. For example: Sunlight and reflection Heat source Objects moving in the wind - -

-Precautions for installing two or more sensors HX-40 HX-40AM HX-40DAM Do not install two or more HX-40DAM s units side-by-side or face-to-face. Instead, install them back-to-back. If mounting on the same wall, be sure they are at least.0 m (3'3") apart from each other..0 m (3'3") or more Less than.0 m (3'3") - PARTS IDENTIFICATION Bracket base Base Screw (3 0 mm) Terminals Main unit PIR sensor (Do not touch) Hood Bracket Shaft cover Anti-masking infrared LED (HX-40AM/DAM only) Lock screw* (M4 35 mm) Screw (4 0 mm) Microwave unit (HX-40DAM only) (Do not touch) LED indicator Lens Cover Lock screw Area masking seal Screw kit For joint For wall mounting For hood Screw (4 0 mm) Screw (4 0 mm) Screw (3 0 mm) *Lock screw attached on bracket base - 3 -

-3 KNOCKOUTS Main unit Bracket Wiring Hole Wiring knockout (Off-the-shelf) magnet switch installation position Wiring Hole Wiring sponge pad For bracket For wall fastening/bracket fastening Up-Down lock screw (installation pitch 83.5 mm (3.9")) Do not touch For wall For switch Up-Down fastening box fastening lock screw Adjustment screw For main unit fastening - 4 -

-4 DETECTION AREA (ft.) 0' 5' 0' Side view (Mounting height: 3.0 m (9'0")) 3.0 m 0' 0' 0' 30' 40' (ft.).0 m MW PIR (Mounting height:.5 m (8'")) 0' 0' 0' 30' 40' (ft.) (ft.) (m) 8 0' 0' 0' 6 4 0 0' Top view 0' 0' 30' 40' (ft.) 4 6 8 0 (m) 0 30 0 40 85 (ft.) 0' 5' 0'.5 m.0 m MW PIR Vertical angle: click (.5 ) upward (Refer to caution in -). 0' 0' (ft.) 4 6 8 (m) PIR MW -5 DETERMINATION OF PIR DETECTION LENGTH To adjust the detection length, apply the masking seals to the back of the lens according to the required detection length. Three types of masking seals are provided. Combine them according to the detection length required. Apply masking seal directly on the back side of the lens. 9.0 m (9'6") 5.5 m (8'") 4.0 m (3'") 3.0 m (9'0") 3.0 m (9'0") 3 3.0 m (9'0") For microwave detection setting please refer to 4 SETTING. - 5 -

INSTALLATION Use the bracket for normal installation. The unit may be mounted directly on the wall, without the bracket, only if the following three conditions are not; The mounting height 3.0 m (9'0"). Horizontal direction adjustment is unnecessary. The ground is level. - MOUNTING WITH BRACKET Using the bracket makes it possible to adjust the unit horizontally by ±90. In cases where the ground is uneven and/or not parallel with the base of the unit, it is possible to adjust the unit vertically by ±0. 90 90 0 0 Caution>> Do not change the detection length with bracket. Use the masking seal to adjust the detection length. Remove the Up-Down lock screw. Push the shaft cover clip straightforwardly with your thumb. In case the clip is stuck, use a suitable tool. e.g. back side of a screw driver. Shaft cover Shaft cover clip 3 Loosen the adjustment screw two turns. 4 Tilt the bracket about 45 and pass through the wire. Adjustment screw Caution>> Do not loosen the screw too much. It may disassemble. In Out - 6 -

5 Determine the horizontal direction (left or right) of the detector before installing the bracket on the wall. To the right To the left 6 Open the wiring knockout. Wiring knockout 7 Open the Up-Down lock screw knockout for connecting the bracket. 8 Tighten screws and, adjust the bracket angle (refer to -), then tighten screw 3. Perform an area check. If re-adjustment is required, loosen screw 3 and change the bracket angle. After the adjustment is complete, tighten screw 3 again. In Knockout with 4 0 tapping screw (screwkit) Wiring hole Wiring sponge pad 4 0 screw Out 34 35 Up-Down lock screw 4 0 screw 9 Tighten the adjustment screw clockwise. 0 Wire to the terminal and install the main unit and lens on the base. Adjustment screw Install the shaft cover into place. - 7 -

- ADJUSTING THE VERTICAL ANGLE For best performance, install detector parallel to the ground. Decide the detection length. If you choose 9.0 m/5.5 m/4.0 m, mask the unnecessary lens with masking seals. Refer to the -5 for the details..0 m (40') Perform the walk test to check if detector is parallel to the ground. 3.0 m (9'0") * This is the case to have m detection length. If the detection length is shorter than the designated one (refer to page 5), change the detector angle upward. If the detection length is longer than the designated one (refer to page 5), change the detector angle downward. If the detection length is equal to the designated one, adjustments have been completed. Caution>> If the base of the unit is already parallel to the ground, Do not change the detection length by tilting the unit up or down. Detection length should be adjusted with masking seal. Refer to -5 and - for the details. Example (the ground is level) 0 is the right setting for 3.0 m (9'0") height installation. Adjust click (.5 upward) for.5 m (8'") height installation. 0 clicks (5 ) 4 clicks (0 ) - 8 -

-3 MOUNTING WITHOUT BRACKET Open the wiring knockout with suitable tool e.g. screwdriver. Pull the wire through the base knockout. In Out Wiring sponge pad 3 Fasten the base to the wall. 4 Install main unit after wiring to the terminal. - 9 -

-4 WIRING Power wires should not exceed the following lengths. WIRE GAUGE HX-40 HX-40AM HX-40DAM V 4 V V 4 V V 4 V AWG (0.33 mm ) 60 m 360 m 40 m 30 m 0 m 50 m (50') (,80') (460') (,00') (390') (80') AWG0 (0.5 mm ) 60 m 560 m 30 m 490 m 80 m 390 m (850') (,840') (750') (,60') (590') (,80') AWG8 (0.83 mm ) 40 m 900 m 360 m 780 m 90 m 630 m (,350') (,950') (,80') (,560') (950') (,070') HX-40AM HX-40DAM TAMPER OUTPUT (N.C.) * AUX INPUT (N.C.) TROUBLE OUTPUT (N.C.) SPARE (Non short) ALARM OUTPUT (N.O.) ALARM OUTPUT (COM) ALARM OUTPUT (N.C.) POWER INPUT (-) (9.5-8VDC) POWER INPUT (+) (9.5-8VDC) HX-40 TAMPER (N.C.) AUX INPUT (N.C.) TROUBLE N.O. COM N.C. + SP SP OUTPUT ALARM POWER T.O.(N.C.) 9.5-8VDC TAMPER (N.C.) AUX N.O. COM N.C. + SP SP INPUT ALARM POWER (N.C.) 9.5-8VDC *: TAMPER terminals to be connected to a 4 hour supervisory loop. - 0 -

-5 WALL TAMPER (OPTION) Universal magnet switch may be mounted as a wall tamper. Installation space for universal magnet switch is provided on the back of the main unit and the bracket. Maximum size of an applicable universal magnet switch: D 9 mm (0.35'') W 40 mm (.57'') H 9 mm (0.35''). Universal magnet switch on the market assist is not included. Main unit Bracket Wiring Hole Magnet switch (Wall side) installation position Magnet switch (Bracket side) installation position Magnet switch (Wall side) installation position Magnet switch (Base side) installation position -Installation Install the universal magnet switch (wall side) to the wall. To determine the install position, use the Install position template provided on the inside cover of the product package. Open the wiring knockout with suitable tool e.g. screwdriver. 3 Install the other portion of the universal magnet switch to the back of the main unit or the bracket. Pull the wiring through the knockouts. When not using the bracket In Fix 4 Wiring sponge pad Out 3 - -

When using the bracket In Fix Tilt the bracket about 45 and pass through the wire. In 4 In 3 Out 6 Wiring sponge pad 5 Out Magnet switch 4 Install the bracket and the main unit to the wall surface. 5 Connect the universal magnet switch wiring to the tamper terminal of the main unit. 3 WALK TEST Set the DIP switch (LED ON/OFF) to ON. Check that the detector detects an object in the intended detection area. The installation has been successful if the LED lights for two seconds after a person walks into the detection area. Detected Not detected Note>> The switch is set ON by factory default. Note>> For the walk test, move more than.0 m (3'3") away from the detector. 3 If the LED indication is not required at all times, set the DIP switch (LED ON/ OFF) to OFF. - -

4 SETTING Do not touch DIP switch. LED ON/OFF. PIR IMMUNITY 3. AUX INPUT 4. TROUBLE OUTPUT 5. MICROWAVE IMMUNITY 6. (Reserved) MW range selector MW sensitivity adjustment PIR sensitivity selector Do not touch HI STD OFF Anti masking sensitibity selector -LED ON/OFF DIP switch HX-40AM HX-40DAM HX-40 POSITION ON (Factory default) OFF FUNCTION The LED lights when someone is detected. The LED does not light even if someone is detected. OFF -PIR IMMUNITY DIP switch HX-40AM HX-40DAM HX-40 STD ON IMMUNITY POSITION STD (Factory default) IMMUNITY FUNCTION PIR IMMUNITY logic is not activated. PIR IMMUNITY logic is activated. Use this under harsh environment (e.g. small animal). - 3 -

-AUX INPUT DIP switch 3 HX-40AM HX-40DAM HX-40 By connecting a satellite unit (another warning sensor), you can extend the detection area and correct false alarms. As a satellite unit, you can use any general no-voltage contact output (NC) warning sensor, including the following. <Infrared (AIR) sensors, thermal line (PIR) sensors, universal magnet switches, etc.> POSITION FUNCTION AND (Factory default) When both the main unit and the satellite detect someone, the alarm is output. Set to this when not connecting a satellite unit. AND OR OR When either the main unit or the satellite detects someone, the alarm is output. Notes>> The alarm does not output unless both the main unit and the satellite detect someone within 60 sec. If the OR mode is selected without a satellite unit connected, the alarm is generated continuously. -TROUBLE OUTPUT DIP switch 4 HX-40AM HX-40DAM HX-40 Trouble output is used for anti-masking signal. When an object is placed close to the lens surface, for a period of more than 80 sec., the IR Anti-Masking circuit is activated and generates a trouble signal. OFF ON POSITION ON (Factory default) OFF FUNCTION Anti-masking signal is output from TROUBLE OUTPUT terminal. Anti-masking signal is output from both TROUBLE and ALARM OUTPUT terminal. Note>> Use this when not wiring a detected trouble input terminal on the control panel. -MICROWAVE IMMUNITY DIP switch 5 HX-40AM HX-40DAM HX-40 POSITION STD (Factory default) IMMUNITY FUNCTION MICRO WAVE IMMUNITY logic is not activated. MICRO WAVE IMMUNITY logic is activated. Use this under harsh environment (e.g. vegetation sway). STD IMMUNITY - 4 -

-MW RANGE SELECTOR/MW SENSITIVITY ADJUSTMENT RANGE SELECTOR/ SENSITIVITY ADJUSTMENT HX-40 HX-40AM HX-40DAM PIR AREA SETTING DETECTION AREA (SIDE VIEW) MW RANGE SELECTOR MW SENSITIVITY ADJUSTMENT.0 m (40') 0 LONG SHORT MID M PIR LONG L H Factory default MW 9.0 m (9'6'') 0 PIR MW SHORT SHORT LONG HIGH M L H 5.5 m (8''') 0 PIR MW SHORT SHORT LONG MID M L H 4.0 m (3''') 3 0 PIR MW SHORT SHORT LONG LOW M L H - 5 -

-PIR SENSITIVITY PIR SENSITIVITY SELECTOR HX-40 HX-40AM HX-40DAM HIGH MIDDLE LOW POSITION HIGH MIDDLE (Factory default) LOW FUNCTION High sensitivity Middle sensitivity Low sensitivity -ANTI-MASKING SENSITIVITY ANTI-MASKING SENSITIVITY SELECTOR HX-40 HX-40AM HX-40DAM HIGH STD OFF POSITION FUNCTION HIGH High sensitivity STD Standard sensitivity (Factory default) OFF Disabled Caution>> When closing the cover, do not leave any object within meter from the unit. 5 AREA ADJUSTMENT -DETECTION LENGTH ADJUSTMENT To limit the detection length, apply the appropriate masking seal. Note that there are three different types of seal. 9.0 m (9'6") 5.5 m (8'") 4.0 m (3'") 3.0 m (9'0") 3.0 m (9'0") 3 3.0 m (9'0") -AREA MASKING Pasting on example for masking No. 5 and No. 6 3 4 5 6 7 8 9 Area masking seal 0 3 7 4 5 56 6 8-6 - 9

6 LED INDICATION Red -HX-40/40AM DETECTOR CONDITION Yellow (HX-40DAM only) Green (HX-40DAM only) Blink Light OFF LED INDICATOR (RED ONLY) Trouble output Warm-up Alarm Anti-Masking booting (Anti-Masking start up) Masking detection -HX-40DAM DETECTOR CONDITION Trouble output Warm-up Alarm PIR detection MW detection Anti-Masking booting (Anti-Masking start up) Masking detection Blinks for approx. 60 sec. Lights for sec. Blinks times and goes off for 5 sec. and then repeats for 80 sec. Blinks 3 times and goes off for 3 sec. and then repeats. LED INDICATOR Blinks for approx. 60 sec. Red lights for sec. Green lights for sec. Yellow lights for sec. Green and Red blink times simultaneously and go off for 5 sec. This sequence is repeated for 80 sec. Green and Red blink 3 times simultaneously and go off for 3 sec. This sequence is repeated. - 7 -

7 SPECIFICATIONS 7- SPECIFICATIONS Model HX-40 HX-40AM HX-40DAM Detection method Passive infrared Passive infrared & Microwave PIR Coverage PIR distance limit Detectable speed Sensitivity Power input Current draw 35 ma (max.) at V DC.0 m (40') 85 wide / 94 zones 4.0 m, 5.5 m, 9.0 m (3'", 8'", 9'6") 0.3 m/s.5 m/s ('/s 4'"/s).0 C (3.6 F) at 0.6 m/s 9.5 8 V DC 40 ma (max.) at V DC.0 ± sec. Approx. 60 sec. (LED blinks) Form C 8 V DC 0. A (max.) 50 ma (max.) at V DC Alarm period Warm-up period Alarm output Tamper output N.C. 8 V DC, 0. A (max.) N.C. open when cover removed. Trouble output N.C. 8 V DC, 0. A (max.) Aux input N.C. 8 V DC, 0. A (max.) LED indicator Red: Warm-up, Alarm Red: Warm-up, Alarm, Trouble Red: Warm-up, Alarm, Trouble Green: Warm-up, PIR detect, Trouble Yellow: Warm-up, MW detect RF interference No alarm 0 V/m Operating temperature -0 +60 C (-4 +40 F) Environment humidity 95% max. Weatherproof IP55 Mounting Wall Mounting height.5 3.0 m (8'" 9'0") Bracket adjust angle Vertical: ±0 Horizontal: ±95 Weight 600 g (. oz.) 700 g (4.7 oz.) Accessories Bracket, Hood, Area masking seal, Screw (3 0 mm), Screw (4 0 mm) 4 *Specifications and designs are subject to change without prior notice. - 8 -

7- DIMENSIONS Using bracket and hood Without bracket and hood 66 (0.47) 99 (3.90) 48 (5.83) 9 (3.6) 05 (8.07) 97.5 (7.78) Unit: mm (inch) Unit: mm (inch) - 9 -

NOTE The following statement will be provided with the equipment as required by Article 6.3 of the R&TTE Directive, 999/5/EC. The Optex HX series are in conformity with all essential requirements of the R&TTE Directive (999/5/EC). This equipment has been assessed to the following standards: EN 300 440-: 009 EN 5030-4: 004 including amendment : 003 EN 60950-: 006+A: 009 This product is marked with which signifies conformity with Class II product requirements specified in the R&TTE Directive. The following table indicates the areas of intended use of the equipment and any known restrictions. For countries not included in this list, please consult the responsible Spectrum Management Agency. Country of intended use Restrictions Country of intended use Restrictions Austria 9.900GHz Luxembourg 0.55GHz Belgium 0.55GHz The Netherlands 0.55GHz Denmark 0.55GHz Spain 0.55GHz Finland 9.900GHz Sweden 0.55GHz France 0.587GHz United Kingdom 0.587GHz Greece 0.55GHz Other non-eu: Iceland 0.55GHz Ireland 0.587GHz Norway 0.55GHz Italy 0.55GHz Switzerland 0.55GHz FCC ID : DC9 OPMW IC : 40A-OPMW This device complies with Part 5 of the FCC Rules. Operation is subject to the following two conditions: () This device may not cause harmful interference, and () this device must accept any interference received, including interference that may cause undesired operation. The HX-40 series is only a part of a complete system, therefore we cannot accept complete responsibility for any damages or other consequences resulting from an intrusion. OPTEX CO., LTD. (JAPAN) (ISO 900 Certified) (ISO 400 Certified) 5-8- Ogoto Otsu Shiga 50-00 JAPAN TEL:+8-77-579-8670 FAX:+8-77-579-890 URL:http://www.optex.co.jp/e/ OPTEX INCORPORATED (USA) TEL:+-909-993-5770 Tech:(800)966-7839 URL:http://www.optexamerica.com/ OPTEX (EUROPE) LTD. (UK) TEL:+44-68-63000 URL:http://www.optexeurope.com/ OPTEX SECURITY SAS (FRANCE) TEL:+33-437-55-50-50 URL:http://www.optex-security.com/ OPTEX SECURITY Sp. z o. o. (POLAND) TEL:+48--598-06-55 URL:http://www.optex.com.pl/ OPTEX KOREA CO., LTD. (KOREA) TEL:+8--79-597 URL:http://www.optexkorea.com/ OPTEX (DONGGUAN) CO., LTD. SHENZHEN OFFICE (CHINA) TEL:+86-755-3330950 URL:http://www.optexchina.com/ - 0 -