Low Temperature Sterilisation ISO 14937

Similar documents
An overview of sterilizer equipment standards current and planned. Richard Bancroft Science & Technical Director STERIS

Best Practice Guidelines For Cleaning, Disinfection and Sterilization of Critical and Semi-critical Medical Devices

Model C 170 CO 2 incubators with hot air sterilization

Teknomar Brand Industrial Type ETO Sterilizer ETO C 1445 Data Sheet

Model CB 220 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

Accurately With HSE COP PT 1 5

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

SDAPharma AUTOCLAVE CHART CHECKING & TESTS. Symonds Davies Associates. e-

Model KBF 240 Constant climate chambers with large temperature / humidity range

PyroButton Catalog. Minimal configuration of PyroButton self-powered data-logger system:

Model KBF 1020 Constant climate chambers with large temperature / humidity range

Introducing The Reliance 200 and 250 Glassware Washing Systems.

No previous protocol.

Model KMF 720 Constant climate chambers with expanded temperature / humidity range

I.F.U Re/Processing Reusable Medical Devices

PQS Quality Assurance protocol. TITLE: Cold Room/Freezer Room:

STERILAB Steam sterilizer with gravitation de-aeration (without vacuum pump) for laboratory purposes.

Model KBWF 240 Growth chambers with light and humidity

INSTRUCTIONS FOR CLEANING AND STERILIZATION OF ALL B.BRAUN AESCULAP HAND HELD SURGICAL INSTRUMENTS AND POWER PRODUCTS (UNITED KINGDOM REQUIREMENTS)

Model KBWF 720 Growth chambers with light and humidity

VHP M100 Biodecontamination Systems

Model KMF 115 Constant climate chambers with expanded temperature / humidity range

SteelcoSure Independent performance verification of your equipment and processes

EUROWASHER. Instruments washer disinfector HSD. Medical device

INSTRUCTIONS FOR CLEANING AND STERILISING HUMECA MEDICAL EQUIPMENT FOR BOTH ELECTRIC AND MANUAL DEVICES

STERIDENT, STERIMAT, STERIMAT PLUS

Part 2-55: Medical electrical equipment. Particular requirements for the basic safety and essential performance of respiratory gas monitors

The Reliance 400/500 Glassware Washers

Washer-Disinfectors - Effectiveness and Quality Assurance. T. Miorini Institute for Applied Hygiene / ÖGSV

SteriTite - The Container System of Choice SteriTite Instructions for Use

FROILABO offers a full range of incubators with natural convection, air forced or forced cooling to cover most laboratory applications.

Processing (cleaning, disinfection and sterilization) of instruments from Smith & Nephew Orthopaedics AG

Incubators, cooled incubators, drying ovens, sterilizers, climatic chambers

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Current Sterilisation Process Content of the Presentation. Content of the Presentation. Prof (Col) Dr RN Basu. Content

THE CSSD BOOK A LITTLE YELLOW INFECTION CONTROL BOOK. Grampians Region Infection Control Group 2014

Constant climate chambers

Proforma for Surveillance of Recognized Environmental Laboratory under the Environment (Protection) Act, 1986

ZL Laboratory freezers

VHP M100 Biodecontamination Systems: Closed Loop

PQS performance specification

Tabletop 2340 EA-D Class S Autoclave 19 Litres

RECOMMENDATIONS FOR CLEANING DEVICES

SteriTite - The Container System of Choice SteriTite

Washing and sterilization systems Serving the pharma industry worldwide

ISO INTERNATIONAL STANDARD. Fire-resistance tests Elements of building construction Part 1: General requirements

Constant climate chamber with ICH-compliant illumination

Instrumentation Division

GAS PIPELINE OPERATIONS

Cleaning and Sterilisation for Burs, accessories and filling material

STERITITE INSTRUCTIONS FOR USE

Constant climate chamber with humidity

ISO INTERNATIONAL STANDARD

SteriTite - The Container System of Choice SteriTite

Cleaning and sterilization solutions

V-PRO LOW TEMPERATURE STERILIZATION SYSTEMS

IQ/OQ Protocol Installation Qualification/ Operation Qualification

Washer Test Kits User Guide

This document is a preview generated by EVS

Additional Cooling Stage (FT174-43) Adds the location points and plumbing for a fourth heat exchanger.

edition version 1.1 Green ICE KW Antibacteria

REAL TIME LABORATORY MONITORING SYSTEM

Constant climate chambers

OVENS. All our ovens are tested to meet electrical safety standard IEC EN , this standard provides additional security for laboratories.

AMSCO Washer/ Disinfectors. Central Sterile Services DISCOVER POWERFUL WASHING WITH INCREASED EFFICIENCIES. One Integrated Approach to Healthcare.

Introduction to Pharmaceutical Freeze Drying

MODEL 6105 FINGERPRINT DEVELOPMENT CHAMBER OPERATIONS MANUAL

PQS Independent type-testing protocol

Dear Valued Customer:

Flexible endoscope automated reprocessing system Safe and user friendly solutions for clinics

IQ/OQ Protocol Installation Qualification/ Operation Qualification zz FreeZone Stoppering Tray Dryer & Bulk Tray Dryer Freeze Dry Systems

Washing and sterilization systems Serving the pharma industry worldwide

PQS performance specification

Constant climate chambers

PQS Independent type-testing protocol

Industrial and cgmp conform Cleaning Equipment

SBS Design Considerations for Autoclave Sterilization

STABILITY ICH. ICH Stability Tests

STABILITY. Stability Storage Chambers & Environmental Stability Rooms

THERMO BUTTON HYGRO BUTTON The smallest temperature and humidity loggers in the world!

Industrial, Medical and cgmp-conform Cleaning Equipment

Laboratory Line. Vertical and Bench-Top Life Science Autoclaves

International Journal of PharmTech Research CODEN (USA): IJPRIF, ISSN: Vol.9, No.3, pp , 2016

MARKING EC Directive 97/23 PED (Pressure Equipment Directive)

Does your equipment meet your needs and the operational capacity stated by the manufacturer?

Cleaning & Sterilization

BS En 285:2006+a2:2009 Description: Sterilization.

DENTAL TABLE TOP STERILIZER SERIES S CLASS MODEL : MO-MOST-T24/45/80.

Cleaning and Sterilization for Instruments & Posts

ISO INTERNATIONAL STANDARD. Liquid hydrogen Land vehicle fuel tanks. Hydrogène liquide Réservoirs de carburant pour véhicules terrestres

The Centron Presidio Monitoring System. Centron. Presidio. Rees Scientific. An ISO 9001:2008 Company

Recommendations for cleaning, decontamination and sterilisation. devices

Technical Datasheet. Suction Controllers, Flow Meters & Accessories

TITLE: Ice-lined Refrigerator or Combined Refrigerator-Icepack Freezer, Compression Specification reference:

Kronos Class B Sterilizer

Australian Standard. Fire detection, warning, control and intercom systems System design, installation and commissioning. Part 1: Fire AS 1670.

Aim. Learning outcomes. 13 May Megan Reilly RN BN Cert IV Assessment & Workplace Training MHlthSc (Inf Control) Immunise Cert MACN CICP 1

Medical Silicone & TPE Tubing

INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Geotechnical investigation and testing Field testing Part 1: Electrical cone and piezocone penetration test

Transcription:

Low Temperature Sterilisation ISO 14937 Validation and Performance Jon Mulhall Senior Validation Engineer ASP Johnson & Johnson Medical 27 th March 2018

What is ISO 14937? A (very) brief history.. In the 90 s there were only standards for steam and ETO sterilizers and nothing for the new generation of sterilizers including low temperature using hydrogen peroxide or ozone for example. In 2001 the ISO committee Click developed to edit Master a subtitle generic style standard for validation that wasn t specific to any technology. 2 2

What is ISO 14937? A (very) brief definition.. ISO 14937 is a generic standard about the requirements to achieve the sterility of medical devices based on a quality management system. No details are given about parameters to measure or how to proceed as there would be with steam for example. Open to interpretation Compliance to this standard is a process which involves the sterilizer manufacturer, the medical device manufacturer and the healthcare facility. Its not a one time process, it s a daily process and should be defined and applied by the healthcare facility. It could include. Procedure to release the load Procedure for the routine control and monitoring of the sterilization process Procedure to maintain the effectiveness of the sterilization process Procedure for the requalification of the sterilizer May involve the validation of other systems associated with the process. I.e. BI incubator or heat sealer. THE VALIDATION OF GAS PLASMA LOW TEMPERATURE STERILIZERS IN COMPLIANCE WITH THE ISO 14937 STANDARD REINFORCES THE QUALITY ASSURANCE IN STERILIZATION. 3 3

What is ISO 14937? Structure and responsibility.. 1. Application field 2. Normative reprimands 3. Definitions 4. Quality system 5. Sterilizing agent characterization 6. Process / equipment characterization 7. Product definition 8. Process definition 9. Validation 10. Routine control and monitoring 11. Product release from sterilization 12. Maintaining process effectiveness Under the responsibility of the manufacturers Under the responsibility of the healthcare facility with support from MDMs 4 4

Pressure Torr What is ISO 14937? How its applied to STERRAD.. 59% H 2 O 2 Injected 760 Inlet valve closed 180 22 6 H 2 O Removed Orifice closed H 2 O 2 to chamber 24 48 5 Concentration Transfer Diffusion Plasma Time Vent 5

Cycle Stages (repeated twice) Warm up start Injection pump down Injection Vapourization pump down Chamber pump down Transfer Pressure check Diffusion Plasma pump down Plasma Vent 6 6

Cycle parameters measured Temperatures - Chamber front 50 C 47 C ~ 56 C - Chamber centre 50 C 47 C ~ 56 C - Chamber rear 50 C 47 C ~ 56 C - Input Door front 50 C 47 C ~ 56 C - Output door rear 50 C 47 C ~ 56 C - Condenser 35 C 30 C ~ 40 C - Vapourizer 75 C 60 C ~ 80 C Pressure - Chamber Hi 0 Torr ~ 1000 Torr - Chamber Lo 0 Torr ~ 30 Torr - Vapourizer 0 Torr ~ 30 Torr 7 Plasma 500W 450W ~ 550W 7

8 Validation process Calibration and verification - Verification of measuring devices used during the validation process (data logger etc) - System and IMS Temperature calibration and verification - System and IMS pressure calibration and verification - System and IMS plasma power verification - System and IMS time verification - H 2 O 2 Monitor calibration. Operation Qualification - Complete cycles (2 injections) for each cycle installed on STERRAD. Performance Qualification - Three half cycles for each cycle installed using a standard test load. Alarm Conditions - Verification of door sensor safety device. - User cycle cancellation - Power failure cancellation 8

Cycle parameters. 9 9

Typical OQ cycle 10 10

Typical OQ cycle 11 11

Typical challenge pack used for PQ testing 12 12

Typical PQ cycle 13 13

14 Documentation of the validation process Profile of the STERRAD Reference to Technical Dossier that was supplied with the STERRAD. Validation procedure Validation report (IQ/OQ/PQ) Appendix A Calibration certificates and product certification forms. Appendix B Alarm condition tests. Appendix C Operational Qualification (OQ) cycle parameters and recorded graphs. Appendix D - Performance Qualifications (PQ) recorded graphs. Appendix E IFU / Calibration procedures / drawing of the load position within the chamber. History of validation List of materials and documents General information about the healthcare facility. 14

Example of the effect of the load.. 15 15

Vapourization pump down The time taken to complete the vapourization pump down phase is a good indication of the overall condition of the STERRAD. 16 16

Future developments.. Being able to provide the validation report in electronic format. 17 17

Q & A 18 18