for relative humidity and temperature

Similar documents
for relative humidity and temperature

QFM21... Siemens Building Technologies HVAC Products. Symaro Duct Sensors. for relative humidity and temperature

Duct Sensors. Siemens Building Technologies HVAC Products. Symaro. for relative humitidy (high accuracy) and temperature

QFM21... Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature

QFM21... Duct Sensors. Siemens Building Technologies HVAC Products

Duct Temperature Sensors

QFM21... Duct sensors. Symaro. for relative humidity and temperature

for relative humidity and temperature with calibration certificates

Room Sensors. Building Technologies HVAC Products ... Symaro. for relative humidity (high accuracy) and temperature

QFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

Duct Air Quality Sensors

Room Temperature Sensors

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

QPM21 Series Duct CO 2 and Air Quality Sensors

Room Air Quality Sensors

Room air quality sensors

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

Duct Temperature Sensors

Q-Series Relative Humidity and Relative Humidity & Temperature Sensors for Critical Environments and Outdoor Air

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

Differential pressure sensors

Technical Instructions Document No. CE1N1961 March 17, Room CO 2 and Air Quality Sensors. Description. Features. Application

QPA63... CO 2 /VOC Sensors. Siemens Building Technologies HVAC Products

Immersion Temperature Controller

Use. In ventilating and air conditioning plants to enhance room comfort and to optimize energy consumption by providing demand-controlled ventilation.

PRELIMINARY EDITION

Room Temperature Controller

Control Thermostat / Thermal Reset Limit Thermostat Combination of electromechanical TR and TW

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications

Frost Protection Thermostat

QAW70. Room Unit. Siemens Building Technologies HVAC Products. for use with heating controllers

Hygro and Hygrothermo Transducers (capacitive) for climatic applications

Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597

Duct Humidity and Temperature Transmitter. Features. IP65 protection. Ordering

THERMASREG TR 040 THERMASREG TR 060

Room Temperature Controller

Room Temperature Controller with LCD

Duct Humidity and Temperature Sensors 0-10 Vdc or 4-20 ma Outputs Passive sensor PT1000, PT100 NTC, NI1000 etc. Features. IP65 protection.

Hygro/hygrothermal transducers (hygrometric)

Heating Controller. Building Technologies HVAC Products. Synco 700

UV Flame Supervision System

MANDÍK MEASUREMENT AND CONTROL SYSTEM

Flame Safeguards LFE10. Building Technologies HVAC Products

Infrared Flame Detectors

No. Icon Name Function

Preliminary Release. Room Temperature

RVP331. Heating Controller for 2 heating circuits, d.h.w. and boiler. Building Technologies HVAC Products

QXA2100. Condensation monitor QXA2101. Monitor to prevent damage caused by condensation on chilled ceilings and HVAC plants with AC/DC 24 V power.

Inductive Conductivity Measurement. Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement symbol.

Flame Safeguards LFE10. Building Technologies HVAC Products

Heating Controller for 2 heating circuits, d.h.w. and boiler, communicating

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

RVP310. Heating Controller. Building Technologies HVAC Products

Semi flush-mount room thermostat

Self-learning Room Temperature Controller

Hygro and hygrothermo transducers (capacitive) for HVAC monitoring

Use. Functions. Key function. Other functions

Heating Element. Building Technologies HVAC Products

Flame detector. The QRA4.U is for use with the following types of burner control:

FTK+ Application. Types Available. Duct sensor for humidity and temperature. Datasheet

HYGROPHIL H process hygrometer

02/11/2015

QRC1... Blue-flame Detectors. Siemens Building Technologies HVAC Products

Flame detector. The QRA4.U is for use with the following types of burner control:

LOA44.252A27. Oil Burner Control. Building Technologies HVAC Products

Room thermostat with Auto Timer, Option External Input

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

In order to minimize the impact of rain, snow, ice and solar radiation on the measurement the EE33-M must be mounted inside a radiation shield.

Self-learning Room Temperature Controller

Self-learning Room Temperature Controller

QRA2... QRA10... QRA53... QRA55... Flame Detectors. Siemens Building Technologies HVAC Products

QRA4.U. Flame Detector. Siemens Building Technologies HVAC Products

Installation plan: PG 8581 PG Mat. no Version 02 GB, IE, AU, NZ

Hygro/hygrothermal transducers (hygrometric)

The fan is switched to the selected speed via control output Q1, Q2 or Q3.

LAE10 LFE10. Use. Series 02

LGA... Gas Burner Controls. Siemens Building Technologies HVAC Products

QRA10... QRA53... QRA55...

Flame detector. Building Technologies Division Infrastructure & Cities Sector

Room thermostats with LCD for wall mounting

LFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02

RVL479. Heating Controller. for use with a partner unit

Room thermostat with Auto Timer, Option External Input

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)

02/11/2015

A T L A S - SolarClimatic Test Cabinet SC 2000 MHG

QRA10... QRA53... QRA55...

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

M7100 Pressure Transducer

QAW70. Room Unit. Building Technologies. for use with heating controllers

RVL470. Heating Controller. Use. Functions. Series B

LFE50. UV Flame Safeguard. Building Technologies Division DETACTOGYR

RH & T Sensors & Humidistats. RH-DT Duct Mount RH & T Sensors. Description

Hygro Transducer / Hygrothermal Transducer and CO 2 Measuring Probe for Climate Monitoring

RVL472. Heating Controller. Building Technologies HVAC Products. Series C. including d.h.w. heating

FlowJam S Ex. Bulk Flow Detection. Operating Instructions. SWR engineering Messtechnik GmbH

Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG DB01

1943P01. Solar Impact Sensor. Sensor for acquiring the impact of solar radiation Output signal DC V 2-wire current output 4...

RVL481. Heating Controller. including d.h.w. heating

Wireless room thermostat with LCD

Transcription:

1 861 1861P01 Duct sensor for relative humidity and temperature QFM65 Operating voltage AC 24 V Signal output DC 0...10 V for relative humidity and temperature Measurement accuracy ±3 % r. h. within the comfort range Use In ventilation and air conditioning plants for acquiring the relative humidity and the temperature in air ducts The QFM65 is used as a control sensor in the supply or extract air duct reference sensor, e.g. for shifting the dew point limit sensor, e.g. in connection with steam humidifiers limit sensor, e.g. for measured value indication or for interfacing with a building management system sensor for enthalpy and absolute humidity, together with the AQF61.1 (refer to Data Sheet 1899) Ordering When ordering, please give name and type reference: duct sensor QFM65 CM1N1861E 23.07.2001 Siemens Building Technologies HVAC Products

Equipment combinations All systems and devices that are capable of acquiring and handling the sensor's DC 0...10 V output signals. Mode of operation Relative humidity Temperature The sensor measures the relative humidity in the air duct with the help of a capacitive humidity sensing element whose electrical capacitance changes as a function of the relative humidity of the air. The electronic measuring circuit converts the sensor s signal to a continuous DC 0...10 V signal, which corresponds to 0...100 % relative humidity. In the range of 1...9 V ( 10...90 % r. h.), the signal is linear to the measurement accuracy given in "Technical data", resulting in an effective measurement range of 10...90 % r. h. The sensor acquires the temperature with the aid of the Pt1000 thin-film measuring element whose electrical resistance changes in function of the temperature of the ambient air. The change in resistance is converted to two DC 0...10 V signals that act independently. One DC 0...10 V signal corresponds to the temperature range 0...50 C, the other to 35...+35 C. Mechanical design The duct sensor consists of housing, removable cover and immersion sensor tube. The housing accommodates the measuring circuit and the connection terminals. The cable is introduced through a threaded hole in the bottom for the Pg 11 cable gland (IP 42) supplied with the sensor or with another Pg 11 cable gland to DIN 46 320 (IP 54). The sensing elements are located at the tip of the immersion sensor tube and protected by a sleeve with a filter. Immersion sensor tube and sensor housing are made of plastic and rigidly connected. The sensor is secured with the help of screws. It can be fitted in 2 different ways: With the mounting flange supplied with the sensor; the flange is placed over the pocket and secured at the required immersion depth, or Without the mounting flange (making use of the maximum immersion depth); for that purpose, the housing has 4 holes Accessories (supplied with the sensor) Mounting flange Cable gland 2/6

Engineering notes The transformer used must be suited for safety extra low voltage (SELV). It must have separate windings and be designed for 100 % duty. The transformer must be sized and fused in compliance with local safety regulations. The power consumption of the QFM65 must be taken into consideration when sizing the transformer. For wiring the sensor, refer to the Data Sheets of the units with which the sensor is used. The permissible cable lengths must be observed. Cable routing and cable selection When laying the cables, it must be observed that the longer the cables run side by side and the smaller the distance between them, the greater the electrical interfrence. Twisted pairs of cables are required for the secondary supply lines as well as for the signal lines. Mounting notes To ensure degree of protection IP 42, the sensor must be fitted with the cable entry pointing downward! The sensor must be mounted in locations where it can be easily accessed for service. Note! If used in connection with steam humidifiers, the distance to the humidifier must be a minimum of 3 m. If permitted by the installation, the distance should be as great as possible, but no more than 10 m The sensing elements in the pocked are susceptible to impact and shock. Any impact or shock should therefore be avoided when mounting the sensor If the application involves dew point shifting, the sensor must be mounted in the extract air duct. Mounting Instructions are printed on the package. Commissioning notes Check wiring before switching on power. No adjustments are required on the sensor itself. The calibration and test potentiometers are protected with a blob of paint. Their settings may not be changed! 3/6

Technical data Humidity sensor Temperature sensor Range of use 10...90 % r. h. Measurement accuracy at 20 C 20...90 % r. h. ±5 % 40...60 % r. h. ±3 % (typically) Temperature dependency 0.1 % r. h. / C Time constant approx. 20 s, in moving air at 0...50 C, 10...80 % r. h. Perm. air velocity 20 m/s Output signal, linear (terminal B RH ) DC 1...9 V 10...90 % r. h., max. ±1 ma Range of use 0...50 C and 35...+35 C Sensing element Pt1000 class B Measurement accuracy at 20 C with L&S Ni 1000 standard circuitry ±0.7 K Time constant approx. 20 s in moving air Output signal, linear (terminal B at50 ) DC 0...10 V 0...50 C, max. ±1 ma Output signal, linear (terminal B at35 ) DC 1...9 V 35...+35 C, max. ±1 ma General sensor data Power supply Cable lengths for the measuring signal Electrical connections Degree of protection and safety class Environmental conditions Operating voltage AC 24 V ±20 % Frequency 50/ 60 Hz Power consumption 0.5 VA Perm. cable lengths with 0.6 mm dia. copper cable 50 m 1 mm 2 copper cable 150 m 1.5 mm 2 copper cable 300 m Terminals screw terminals, max. 2 1.5 mm 2 Cable cland Pg 11 Degree of protection of housing With enclosed cable gland IP 42 to IEC 529 With cable gland to DIN 46 320 IP 54 to IEC 529 Safety class III to EN 60 730 Operation to IEC 721-3-3 Climatic conditions class 3K5 Temperature (housing with electronics) 5...+50 C Humidity 5...95 % r. h. (non-condensing) Transport to IEC 721-3-2 Climatic conditions class 2K3 Temperature 25...+70 C Humidity <95 % r. h. Mechanical conditions class 2M2 4/6

Materials and colors Norms and standards Base Polycarbonate, RAL 7001 (silver-grey) Cover Polycarbonate, RAL 7035 (light-grey) Sensor tube Polycarbonate, RAL 7001 (silver-grey) Sensor head Polycarbonate, RAL 7035 (light-grey) Mounting flange Polycarbonate, RAL 7001 (silver-grey) Sensor (entirely) silicon-free Packaging corrugated cardboard Product safety Automatic electrical controls for household and similar use EN 60 730-1 Electromagnetic compatibility Immunity EN 61 000-6-2 Emissions EN 50 081-1 conformity to EMC directive 89/336/EEC Low voltage directive 73/23/EEC conformity to Australian EMC Framework Radio communication act 1992 Radio Interference Emmission Standard AS/NZS 3548 Weight Incl. packing approx. 0.275 kg 5/6

Connection terminals G M BRH Bat50 Bat35 1861G01 G, M Operating voltage AC 24 V (SELV) G System potential (SP) M System neutral (SN), measuring neutral B RH Signal DC 1...9 V for 10...90 % r.h. B at50 Signal DC 0...10 V for temperature measuring range 0...50 C B at35 Signal DC 0...10 V for temperature measuring range 35...+35 C Dimensions (in mm) 19,5 56 ø 22 ø 12 32 6 292 max. 228 249 Pg 11 86 1861M01 42 4 50 5 42 (50) 3,2 1861M02 42 68 42 (68) min. 22 (12) Mounting with mounting flange Mounting without mounting flange Drilling template with (without) mounting flange 6/6 2000 Siemens Building Technologies Ltd. Subject to change