MATERIALS Traps TRAPS. No. IPC IRC Description

Similar documents
Read Only Document Not For Distribution

Level I Chapter 1 Worksheet

CHAPTER 31. VENTS Reserved 2003 INTERNATIONAL RESIDENTIAL CODE 425R

STACKS AND STACK VENTS

PLUMBING REQUIREMENTS

SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- PLUMBING

Summary of BBS Proposed Ohio Plumbing Code Rule Changes October 2016

IPC Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer.

CHAPTER VI BUILDING PLUMBING

ICP Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer.

CHAPTER 9 VENTS. run undiminished in size and as directly as possible from the building drain through to the open air above the roof.

CHAPTER 9 VENTS SECTION

1 Exam Prep Plumber s Handbook Tabs and Highlights

Sanitary Drainage Systems

A GUIDE TO PASSING THE PLUMBING EXAM

Methods of Venting Plumbing Fixtures and Traps in the 2018 IPC

Read Only Document Not For Distribution

IPC Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer.

PLUMBING FIXTURES CHAPTER 27

APPENDIX L ALTERNATE PLUMBING SYSTEMS

ENERGY MARKETING SERVICES

PLUMBING FIXTURES Reserved

PLUMBING INSTALLATIONS

plumbing for greywater

Special Requirements For Health Care Facilities

CHAPTER 10 TRAPS AND INTERCEPTORS TABLE 10-1 HORIZONTAL LENGTHS OF TRAP ARMS (EXCEPT FOR WATER CLOSETS AND SIMILAR FIXTURES) 1, 2

GIANT. Little. Guidelines for Sizing. Pump Company. Sewage Pumps & Systems. Sewage Pumps & Systems

Test Code: 8117 / Version 1

2015 UPC CODE - CHAPTER 8 INDIRECT WASTES

CUSTOMIZED TEACHER ASSESSMENT BLUEPRINT PLUMBING. Test Code: 5924 Version: 01

Wastewater. Guidelines for Sizing mscdirect.com. Call MSC today to learn about the latest LittleGiant products.

Drain and Vent Systems 6 CE Hours

Pro Vent TM. Provent Systems Inc Capital Circle Lawrenceville Georgia

2016 Plumbing Supplemental Plan Review List

TABLE OF CONTENTS Limitations of Authority...6 Table Swimming Pool, Spa, and Hot Tub Permit Fees...7

TABLE OF CONTENTS. CHAPTER 2 DEFINITIONS General Applicability Definition of Terms General...

TABLE OF CONTENTS. Part I Administrative... 1

Building Utilities 1 Plumbing and Sanitary Systems

CHAPTER 10 TRAPS AND INTERCEPTORS

Read Only Document Not For Distribution

GARCIA GALUSKA DESOUSA Consulting Engineers

Read Only Copy Not For Distribution. Chapter 10. Water Supply and Distribution 10.1 QUALITY OF WATER SUPPLY 10.2 RESERVED 10.

TABLE OF CONTENTS Limitations of Authority...6 Table Plumbing Permit Fees...7

1 Exam Prep Plumbing State Contractors Practice Exam 2

2015 UPC Chapter 8 Indirect Wastes RV

APPENDIX A. A 3.2 Determine the elevation of the highest. A 3.3 Subtract the sum of loss in static pressure

TABLE OF CONTENTS. CHAPTER 2 DEFINITIONS General Applicability Definition of Terms General...

ASME STANDARDS IN MODEL CODES

Is Sewer Gas Giving Your Customers the Wrong Impression?

2009 IPC ,IMC Q &A ANDIFGC

Land Use and Environmental Service Agency (Code Enforcement) Plumbing 2010

ProVent Systems Plumbing Fundamentals. Educational Literature. Comparison of ProVent Design Rules and The International Plumbing Code

Pipe Sizing Table. Hydraulic Load Served (fixture units)

STUDENT NOTES Plan, size and layout sanitary pipe work and fixtures

DUKE UNIVERSITY CONSTRUCTION STANDARDS

Matrix of changes for the National Standard Plumbing Code July 2013

INSPECTION OF COMMERCIAL KITCHEN PLUMBING

DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES

Gulfport, Mississippi 21 May 2007

PLUMBING CODE REFERENCE Second Edition

Code 3Check Plumbing. Third Edition. INTRODUCTION u CODES u ABBREVIATIONS. Abbreviations. By michael casey, douglas hansen & Redwood Kardon

CALIFORNIA PLUMBING CODE MATRIX ADOPTION TABLE APPENDIX A - RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYSTEM 1 2 1/AC AC SS SS/CC

CHAPTER 10 TRAPS AND INTERCEPTORS The vent pipe opening from a soil or waste No more than one (1) approved slip joint

Denotes a new question! Denotes a revised/revisited question. September 2009 General:

CHaPTeR 10. TRaPS and INTeRCePTORS. Table 10-1 Horizontal lengths of Trap arms (except for water closets and similar fixtures)*

Plumbing Guidelines 2012 IBC/ANSI A

INSTALLATION MANUAL. Manufactured by AQUA-AIR MANUFACTURING. (801) or (800) FAX (801)

Plumbing. Definitions. Background Factors. Air Chambers. Air Gap (Drainage System) Air Gap (Water Distribution System) Air Lock.

2012 Virginia Plumbing Code & VRC (Plumbing) Update Training

PLAN REVIEW SUBMITTAL GUIDE

Chapter 4: Fixtures, Faucets & Fittings:

Union County Vocational - Technical Schools Scotch Plains, New Jersey

DESIGN STANDARDS SECTION PLUMBING FIXTURES AND EQUIPMENT. 1.3 Wall hung toilet room fixtures. Urinals for handicapped may be stall type.

APPENDIX J ILLUSTRATIONS

AN ORDINANCE TO AMEND CHAPTER 7-BUILDING REGULATIONS, ARTICLE 1-UNIFORM CONSTRUCTION CODE, SECTION 7-2 -FEES TO ESTABLISH A NEW FEE SCHEDULE

2016 CALIFORNIA CODES KITCHEN, BATH & LAUNDRY REMODEL REQUIREMENTS

Plumbing Guidelines 2015 Minnesota Accessibility Code Based on the 2012 IBC and 2009 ANSI A117.1

SECTION PLUMBING

Frequently Asked Questions

DOMESTIC WATER PACKAGED BOOSTER PUMPS

Mechanical Inspection Plumbing

Perkins Statewide Articulation Agreement. Documentation item: Secondary Competency Task List Coversheet

DEFINITIONS CHAPTER 2

Plumbing Technology/Plumber CIP Task Grid

DESIGN STANDARDS SECTION Toilet rooms and utility rooms to have floor drains at lowest point.

A. All fixtures shall meet the requirements of ANSI A117.1, ANSI Z124.2 and the State of Texas Accessibility Standards (TAS).

TUBS & SURROUNDS FIBERGLASS TUB STANDARD FIBERGLASS GARDEN TUB

FIXTURES, FAUCETS AND FIXTURE FITTINGS

2. Sanitary Plumbing General Installation Requirements

DEFINITIONS CHAPTER 2

Bill de Blasio, MAYOR. build safe live safe. Rick D. Chandler P.E., COMMISSIONER

CHAPTER 10 TRAPS AND INTERCEPTORS

SAFETY PLUMBING PACKAGES. Quality Products & Value Packages SUSTAINABILITY. Residential Solutions ANTI-SCALE SYSTEMS FIRE PROTECTION

BACKFLOW PREVENTION GUIDE FOR COMMERCIAL, INSTITUTIONAL AND INDUSTRIAL DEVELOPMENTS

PLUMBING DESIGN GUIDELINES SECTION DESIGN GUIDELINES DUVAL COUNTY PUBLIC SCHOOLS

CHAPTER 4 FIXTURES WHAT FIXTURES ARE REQUIRED? SINGLE-FAMILY RESIDENCE

PRE-INSTALLATION GUIDE

CONTINUING EDUCATION UPC Definitions Code Course. 4 hours Course # ID09143 (CODE) PO Box Spokane, WA

A. Section Joint Sealants: Seal fixtures to walls and floors.

AIRPORT PLUMBING DESIGN STANDARDS REV. 2 11/02/2015

Transcription:

MATERIALS Traps TRAPS MAX " MAX 0" No. IPC IRC Description 00. P0.6 00. P0.6 00. P0. 00. () P0.6 Exc. Vertical distance from fixture to the trap weir can not exceed ". Horizontal distance from the fixture outlet to the centerline of the trap inlet can not exceed 0". Each fixture trap must have a liquid seal of not less than " and not more than ". Combination plumbing fixture can share a trap as long as one compartment is not more than 6" deeper than the other compartment and compartment outlets are 0" or less apart. YOU SHOULD KNOW: IPC 908., 00. AND IRC P0.7 IPC 908., IRC P07.: An individual vent is permitted to vent two traps or trapped fixtures as a common vent. IPC 00., IRC P0.7 & TABLE P0.7: Fixture trap size shall be sufficient to drain the fixture rapidly and not less than the size located in 709.. For additional resources visit www.code-ref.com 7

PERMITS AND INSPECTION PERMITS (IRC R0 IPC 06) REQUIRED (IRC R 0. IPC 06.) Construction, alteration, removal, or repair of any plumbing system. APPLICATION (IRC R0. IPC 06.) Submit application to local building department. Submit two or more sets of all supporting construction documents. Code official can waive the requirement for submitting supporting construction documents. ISSUANCE (IRC R0.., IRC 0.6 IPC 06.) Typically issued for a period of 80 days. Time extensions can be granted for up to 80 days. May be revoked or suspended if false information was provided on the application. VALIDITY ENFORCEMENT (IRC R0. IPC 06..) Code official has the right to enter the premises to make inspections Code official is to enforce the code and act on any relative questions Code official must carry proper identification when performing his duty www.dewalt.com/guides

PERMITS AND INSPECTION NOT REQUIRED (IRC R0. IPC 06.) Maintenance such as repairing leaks to any plumbing system as long as a replacement is not necessary. Removal and reinstallation of water closets. CODE COMPLIANCE FOR EXEMPT WORK (IRC R0. IPC 06.) Although an inspection will not be performed, you are required to follow codes. INSPECTIONS (IRC R09. IPC 07) Underground (IRC R09.. IPC 07.) Made after trenches or ditches are excavated and bedded, piping is installed, and before backfill is placed. Rough-In (IRC R09.. IPC 07.) Prior to installation of drywall but after the roof, framing, fire-blocking, fire-stopping, draft-stopping, and bracing is in place and all sanitary, storm, and water distribution piping is roughed-in. Final (IRC R09..6 IPC 07.) After the building is complete and when all fixtures are in place and ready for use. For additional resources visit www.code-ref.com

TESTING PROCEDURES Gauges GAUGES No. IPC IRC Description.().().() P0.8 # P0.8 # P0.8 # Use a gauge having increments of psi or less for tests requiring a pressure greater than 0 psi but less than or equal to 00 psi. Use a gauge having increments of psi or less for tests requiring a pressure greater than 00 psi. Use a gauge having increments of 0.0 psi or less for tests requiring a pressure of 0 lbs. per square inch or less. YOU SHOULD KNOW: IPC AND IRC P0. The permit holder is responsible for required testing. 0 www.dewalt.com/guides

BATHROOM Minimum Code Requirements IPC 0.. and IRC 07. " IRC " IRC IRC IRC " Min. " Min. " Min. Clearance in front of fixtures at least " www.dewalt.com/guides

BATHROOM Vent and Drain Options VENT AND DRAIN OPTIONS Lavatory Water Closet Flange Building Drain No. IPC IRC Description Bathtub 906. 0. Allowable distance of the trap from the vent is based on the pipe size. (See on page 6) 90. 07. A vent system serving each building drain must have at least one pipe that extends to the outdoors. (See additional requirements on page 6) 908. 07. An individual vent is allowed to vent two traps or trapped fixtures. (See additional requirements in the IPC Section 908/909 and IRC 07 and 08) YOU SHOULD KNOW: IPC 90. & IRC 09.: Offsets are not allowed in waste stack vents between the lowest fixture drain and the highest fixture drain. NOTE: Waste stack vents shall not receive discharge from water closets or urinals. IPC 909 & IRC 08.: Horizontal wet vents, those drainage pipes that serve as both drain and vent purposes, are allowed for any combination of fixtures within two bathroom groups located on the same floor. www.dewalt.com/guides

BATHROOM Drain Pipes DRAIN PIPES IPC 706. & IRC 00. Fitting Type Horizontal to Vertical Vertical to Horizontal Horizontal to Horizontal Sixteenth Bend (. ) Eighth Bend ( ) Sixth Bend (60 ) Quarter Bend (90 ) Short Sweep " or smaller fixture drains only " or smaller fixture drains or " or larger " or smaller fixture drains only " or smaller fixture drains only Long Sweep Sanitary Tee Wye Combo Wye and /8 Bend Fittings must be oriented to guide the flow of drainage. For additional resources visit www.code-ref.com

BATHROOM Vent Termination VENT TERMINATION Minimum 6" No. IPC IRC Description 0. Open vent pipes must extend at least 6" above the roof or anticipated snow accumulation level (whichever is greater). 90. 0. If a roof is used for any purpose other than weather protection (such as a deck), the vent must extend at least 7' above the roof. 90. 0. Vents can not terminate directly beneath doors, windows or other air intake openings of the building or adjacent buildings. 90. 0. Vents that terminate within ' 0' horizontally of a door or window must extend at least ' above such opening.. Air Admittance Valves that terminate in the attic must be extended at least 6" above the insulation level. 6 www.dewalt.com/guides

BATHROOM Cleanouts Building Drain Foundation Wall CLEANOUTS Cleanout or greater requires cleanout /8 bends cleanout not required Building Sewer Vertical Waste or Soil Stack Building Drain Cleanout required No. IPC IRC Description 708.. 00.. Cleanouts must be extended vertically to or above grade when installed underground. 708.. 00.. Cleanouts must be installed for all changes in direction greater than. (Where more than one change of direction occurs, only one cleanout is required for every 0'.) 708.. 00..7 Cleanouts must be installed at the junction of the building drain and building sewer. 708.. 00..6 Accessible cleanouts must be installed at the base of each vertical waste or soil stack. YOU SHOULD KNOW: IPC 708.., 708.7, IRC 00..9 AND 00.. IPC 708.7 & IRC 00..9: Cleanouts must be the same size as the pipe served up to ". For larger pipes, the cleanout only has to be at least ". IPC 708.. & IRC 00..: Cleanouts must be provided no more than 00' apart in horizontal drainage lines. For additional resources visit www.code-ref.com 7

BATHROOM Water Piping Hot and Cold Water Lines WATER PIPING HOT AND COLD WATER LINES 6" 8" 9" " No. IPC IRC Description 60. 90. Approved water distribution pipe includes CPVC, PEX, and copper. A complete list of approved material can be found as referenced. 60. 90.7 Water supply line size requirements vary based on the type of fixture. (See on page 66) Typical Installation Typical Installation Lavatory water stub-out should be between 9 and " from the floor. Space between hot and cold water stub-out for lavatory should be between 6 and 8". 0.8 60.. Shield plates must be installed to protect pipes if the whole bored for installation is closer than. from nearest edge. 8 www.dewalt.com/guides

BATHROOM Water Closet WATER CLOSET Fill Valve Toilet lever Float cup/ sensor Water Supply IRC P7. Min. " to critical level of fill valve Overflow tube Flapper Flush valve Shut off valve Vent Flange Integral trap Toilet bowl Main drain Wax seal IPC IRC Description 7 Water closets are manufactured per code standards and will be in compliance with sections of the IPC and 7 of the IRC. For additional resources visit www.code-ref.com 9

BATHROOM Bathtub BATHTUB No. IPC IRC Description 07. 7. Drain outlet of at least /" is required with an approved waste stopper. 709. 0.7 Trap size must be at least /". (See on page 67) 60. 90.7 Hot and cold water supply must be at least /". (See on page 66) 60. 708. /" riser to the shower head is required and must be attached to the structure. YOU SHOULD KNOW: IPC 0.8 AND IRC 70. Slip joint type P-Traps can only be used if an access panel or utility space of at least a " dimension is provided. www.dewalt.com/guides

BATHROOM Hydromassage Bathtub HYDROMASSAGE BATHTUB No. IPC IRC Description 07. 7. 709. 0.7 Minimum outlet must be at least /" diameter. P-Trap must be at least /". (See on page 67) 0.7.. P70. Overflow must discharge into the drainage system. Access door must be provided for pump maintenance and must be of adequate size to allow removal. Access door must be at least " ". In cases where the pump is more than ' from the opening, the access must be 8" 8". YOU SHOULD KNOW: IPC. Hydromassage bathtubs must be installed with the manufacturer s instructions and tested in accordance to the manufacturer. For additional resources visit www.code-ref.com

UTILITY ROOM Automatic Washing Machine AUTOMATIC WASHING MACHINE 7 6 MIN 8" MAX " No. IPC IRC Description 06. 0.7 06. 00. 06. 78. 60. 90.7 80. 0.6 6 80. 706. 7 96. Trap and fixture drains must be at least ". Fixture drain must connect to a horizontal drain or drainage stack that is at least " diameter. Waste water must be discharged through an air break into a standpipe. Water supply must be at least /". Each standpipe must have an individual trap. Standpipes must be at least 8" above the crown weir but no more than ". (IRC specifies at least 0" from standpipe outlet to weir.) Vent must be at least /" www.dewalt.com/guides

UTILITY ROOM Utility Sink UTILITY SINK RED Hot water line from water heater BLUE Cold water line from water supply 6 7 8 No. IPC IRC Description. 8. P7. Each compartment of a laundry or utility sink shall have a minimum /" drain outlet. 608... P90. If faucet to be used has hose threads on the spout, it must have either a built-in vacuum breaker or one has to be installed on faucet spout. 709. 60. 60. P7. Minimum /" P-Trap. P90.7 Hot water line must be a minimum of /". P90.7 Cold water line must be a minimum of /". 6 96. P. Vent must be a minimum of /". 7. P7. Sanitary tee must be a minimum of /". 8. P7. Drain pipe must be a minimum of /". For additional resources visit www.code-ref.com

KITCHEN Sinks SINKS 6 RED Hot water line from water heater BLUE Cold water line from water supply No. IPC IRC Description 8. P7.. P76. Waste outlets for sinks must be at least /" and feature a strainer or crossbar to restrict the clear opening of the waste outlet. Drain for the garbage disposal must be at least a /" drain outlet. 09. 80..6 80..7 P77. P77. P77. The waste water from a dishwasher must discharge in one of the following manners: (a) directly through an air gap or air break. (b) discharge into a wye branch fitting on the tail piece of a kitchen sink drain or food grinder. 60. P90.7 Hot water inlet to the dishwasher must be at least /" 709. P77. Dishwasher, disposal, and kitchen sink can share the /" waste drain pipe. (See on page 67) 6 60. P90.7 Branch lines for hot and cold water must be at least /". 6 www.dewalt.com/guides

KITCHEN Air Admittance Valve HOW IT WORKS AIR ADMITTANCE VALVE MIN " Air admittance valves are pressure-activated, one-way vents used where outdoor venting is not desired. (Commonly used for island kitchen sinks.) When wastewater discharges, it causes the valve to open, releasing the vacuum and allows the air to enter the vent for proper drainage. Otherwise, the valve remains closed and prohibits the sewer gases to escape to the room. YOU SHOULD KNOW: IPC 97 AND IRC P IPC 97. & IRC.: Air admittance valves must be installed after the DWV pressure testing. IPC 97.8: Prohibited Installations Air admittance valves can not be located within spaces utilized for return air or for air supply. IPC 97..: If vent stacks or stack vents exceed six branch intervals, the stack shall not serve as a drainage vent terminal. IPC 97.: Air admittance valves must be located at least " above the fixture drain. For additional resources visit www.code-ref.com 7

KITCHEN Island Fixture Venting ISLAND FIXTURE VENTING No. IPC IRC Description 9.. Island fixture venting is not allowed for fixtures other than sinks and lavatories. Such fixtures are permitted with a dishwasher waste connection, a food waste grinder or both. 9.. Island vents must extend vertically above the drainage outlet of the fixture being vented before offsetting (vertically or horizontally) 9.. Cleanouts must be provided in the island fixture vent to permit rodding of all vent piping located below the flood level rim of the fixtures. 97.. Air admittance valves are allowed for the purpose of venting island fixtures. 8 www.dewalt.com/guides

WATER HEATERS Attic Installation ATTIC INSTALLATION 6 No. IPC IRC Description 0. M0.. Water heaters must always be installed in locations feasible for observation, maintenance, and replacement. 0. M0.. Access must be at least 0" 0" or large enough for removal of water heater. 0. M0.. Access can be no more than 0' from the water heater. 0. M0.. The path to the water heater must be solid flooring no less than " wide. 0. M0.. A level work area (service space) at least 0" 0" must be provided in front of the water heater. 6 0.6 P80.. Required: Pan with drain that runs to the exterior of the building terminating no less than 6" and not more than " from the ground. YOU SHOULD KNOW: When pipes are exposed in an unheated space, insulation and heat source is required to prevent freezing. For additional resources visit www.code-ref.com 9

WATER HEATERS Tankless Water Heater TANKLESS WATER HEATER E E A B Ltr. A B C D E F G HOW IT WORKS Step Step : Fixture hot water valve is turned on. Step : Water flows through the heater. Step : Water flow activates burner control. Step : Burner is ignited. Step : Heat exchanger heats the water as water flows through. Step 6: Burner adjusts to heat the water to the specified temperature. Step 7: When the fixture burner shuts down, water flow is turned off. YOU SHOULD KNOW Water heaters must be installed in compliance with Chapter 8 of the IRC and Chapter of the IPC. NOTE: All water heaters must be installed in accordance with the manufacturer s installation instructions. www.dewalt.com/guides

SILL COCKS SILL COCKS Sill Cock Hose Connection Vacuum Breaker Hose Bibb No. IPC IRC Description 608... P90.. 0 R0 All sill cocks, hose bibbs, wall hydrants, and other openings with a hose connection must be protected by an atmospheric-type vacuum breaker, pressure-type vacuum breaker, or a permanently attached hose connection vacuum breaker. Exceptions: water heater boiler drain and hose bibbs for washing machines. Vacuum Breaker An anti-siphon device that prevents waste water from being drawn back into supply lines, potentially contaminating the water supply. YOU SHOULD KNOW The shank of the sill cock faucet extends into the wall or crawl space 6" ". This makes the faucet freeze-proof. If a garden hose is left connected to the faucet in the winter, the faucet may freeze. Garden hoses are the number one cause for cross connection backflows; causing contamination of our drinking water. 8 www.dewalt.com/guides

BACKFLOW PREVENTION Air Gap AIR GAP Underneath Salad Bar Air Gap Sink Air gap is a means of preventing backflow. No. IPC IRC Description 0 R0 Air Gap (Drainage System) The unobstructed vertical distance through the free atmosphere between the outlet of the waste pipe and the flood rim of the receptacle into which the waste pipe is discharged. 0 R0 Air Gap (Water Distribution System) The unobstructed vertical distance through the free atmosphere between the lowest opening from any pipe or faucet supplying water to a tank, plumbing fixture, or other device and the flood level rim of the receptacle. 0 R0 Indirect/Waste pipe. 0 Diameter of the pipe. 6 80.. P90.. Distance of the air gap is determined by multiplying the diameter of the pipe times two. Minimum ". (i.e.: A pipe with a " diameter would need a minimum of a " air gap) 6 Waste receptor such as a floor sink. For additional resources visit www.code-ref.com 9

ISOMETRICS Commercial Restrooms To size the Horizontal Branch Drain Sizing, calculate the total DFUs first. TABLE 709.: DRAINAGE FIXTURE UNITS FOR FIXTURES AND GROUPS Fixture Type DFU Value As Load Factors Minimum Size of Trap Automatic clothes washers, commercial a,g Automatic clothes washers, residential g Bathroom group as defined in Section 0 Multiply the quantity by the DFU value (.6 gpf water closet) f to determine the total. Bathroom group as defined in section 0 6 (water closet flushing greater than.6 gpf) f DFU CALCULATIONS Bathtub b (with or without overhead shower or whirlpool attachments) No. / Fixture Qty. DFU Total Bidet / Combination sink and tray / Floor Drain 0 0 Dental lavatory / Dental unit or cuspidor / Dishwashing machine c, domestic Lavatories / Drinking fountain / / Emergency floor drain 0 Urinals 8 Floor drains Kitchen sink, domestic Water / 6 Kitchen sink, domestic with food waste grinder Closet and/or dishwasher / Add together = 6 DFUs Laundry Tray ( or compartments) / Lavatory / Shower / Service sink / Sink / Urinal Noted Urinal, gallon per flush or less e Noted Urinal, nonwater supplied 0. Noted Wash sink (circular or multiple) each set of faucets / Water closet, flushommeter tank, public or private e Noted Water closet, private (.6 gpf) e Noted Water closet, private (flushing greater than.6 gpf) e Noted See full Water closet, public (.6 gpf) e Noted Water closet, public (flushing greater than.6 gpf) 6 e Noted on page 67. For additional resources visit www.code-ref.com

ISOMETRICS Commercial Restrooms A horizontal branch is a drainage branch pipe extending laterally from a soil or waste stack or building drain that receives the discharge from two or more fixture drains or branches and conducts the discharge to the soil or waste stack or to the building drain. A branch interval is a vertical measurement of distance, 8 feet or more in developed length between the connections of horizontal branches to a drainage stack. A stack is a general term for any vertical line of soil, waste, vent or inside conductor piping that extends through at least one story with or without offsets. Diameter of Pipe (inches) TABLE 70.(): HORIZONTAL FIXTURE BRANCHES AND STACKS a Total for horizontal branch Max. Number of Drainage Fixture Units (DFUs) Total discharge into one branch interval Stacks b Total for stack of three branch intervals or less Total for stack greater than three branch intervals / 8 6 6 0 / 9 0 0 0 8 7 60 90 0 00 60 00 0,00 See full on page 68. Size the horizontal branch drain based on the information from page. Total DFUs from men s and women s restrooms is 6. The correct column to use is Total for horizontal branch. The diagram is a single story and horizontal branch is not connected to a stack. Find the number in column B that will accommodate 6 DFUs. In this case, the 60 DFU value would have to be used. Follow that row to the left column: Diameter of Pipe which indicate the size of horizontal branch needed. 6 www.dewalt.com/guides

ISOMETRICS Commercial Restrooms COMMERCIAL RESTROOM ISOMETRICS 7 9 8 0 7 No. 6 Description 9 NOTE: This vent pipe is not required by code, but is ok to be installed. The branch drain line having a slope of /8" shall be " in diameter. A " can convey a maximum of 60 DFUs. A total of 6 DFUs were calculated on the previous page. 6 " ½" fixture fittings are required for lavatory drainage. 7 ½" double fixture fittings are required to convey drainage from back-to-back lavs. ¼" P-Traps for lavs. 9 7 0 8 9 " " fixture fittings are required for all hung closet and urinal drainage. " single water closet carrier is required for wall hung water closets. " " sanitary tees are required for urinal drain connections. For additional resources visit www.code-ref.com 7

ISOMETRICS Commercial Restrooms COMMERCIAL RESTROOM ISOMETRICS (cont.) NOTE: This vent pipe is not required by code, but if installed 8 will require a " cleanout with plug with reducing bushing. 8 7 No. Description " " fixture fittings is required for drain connection of floor drain. " double fixture fittings or " double sanitary tee is required for both floor drains. " floor drains shall have trap primers to prevent sewer gases from entering restrooms. " " fixture fittings are required for wall hung water closet drain connection. " double water closet carrier is required for back-toback wall hung water closets. 7 Two /8" bends or one longsweep ¼" bend is required. 8 " cleanout w/plug. 8 www.dewalt.com/guides

ISOMETRICS Commercial Restrooms COMMERCIAL RESTROOM ISOMETRICS (cont.) NOTE: Less than 0' vent length assumed. 6 0 8 7 9 No. Description NOTE: This vent pipe is not required by code, but is ok to be installed. 8 6 0 A ¼" 90º elbow is required to be installed for vent connection. A ½" ¼" bushing or reducer shall be installed on top of fitting at #. A ¼" ¼" ¼" tee is required to be installed for vent connection. A ½" ¼" shall be installed on top of fitting at #7. A ½" ½" ¼" tee is required to be installed for vent connection. A " ¼" bushing or reducer shall be installed on top of the fitting at #. A ½" ¼" ½" tee is required to be installed for vent connection. A " ¼" bushing or reducer shall be installed on top of the fitting at #. A " ½" ½" tee is required to be installed for vent connection. A " ½" bushing or reducer shall be installed on top of the fitting at #9. A " ½" ½" tee is required to be installed for vent connection. A " ½" bushing or reducer shall be installed on top of fitting at #. For additional resources visit www.code-ref.com 9

ISOMETRICS Commercial Restrooms COMMERCIAL RESTROOM ISOMETRICS (cont.) 6 0 9 8 NOTE: This vent pipe is not required, but if installed, 8 will require a " cleanout with plug with reducing bushing, 9 a tee, and 0 a vent. No. 6 Description A " " " tee is required for vent connection. A " " bushing or reducer is necessary on top of the fitting at #. 9 A 90 EL is required for vent connection. 0 A " vent shall be installed to vent all fixtures through the roof. (Assuming 0 feet or less vent length.) YOU SHOULD KNOW This is not by scale. Always check with local codes that may apply. The above would be the same if the water closet were floor mounted. There would be a difference if the water closets were tank type instead of flush valve. Check tables in code book. 60 www.dewalt.com/guides

ISOMETRICS Commercial Restrooms Lavatories COMMERCIAL RESTROOM ISOMETRICS LAVATORIES Lavatories (back to back) NOTE: Assume sizing for 00 feet developed length and 9 PSIG pressure. 6 No. Description /" /" /" Tee Upstream there are 6 WSFUs (cold). Using the table, count the value (WSFU) of the different fixtures that will have hot water. " /" /" Tee Upstream there are 76 WSFUs. Using the table, count the value of the different fixtures that will have cold water. /" Tee /" 90 Ell /" Caps 6 /" /" /" Tee For additional resources visit www.code-ref.com 6

ISOMETRICS Commercial Restrooms Water Closets COMMERCIAL RESTROOM ISOMETRICS WATER CLOSETS Water Closets (back to back) 6 0 6 6 0 0 9 6 6 0 6 9 6 8 8 Ladies Water Closets and Men s Urinals (back to back) No. Description 8 /" /" " Tee 9 " /" " Tee 0 " Cap /" Tee /" Cap /" 90 Ell /" " " Tee " Tee 6 " 90 Ell 6 www.dewalt.com/guides