BL41 Extra-long Barrier

Similar documents
Engineering Specifications

BLG77 Rising Fenced Barrier

BL 53 Security Barrier ENGINEERING SPECIFICATIONS

Security Entrance Lane

Architectural Specification Sheet

security resources international PART I: GENERAL eguardian Series 1.01 SUMMARY 1.02 REFERENCES 1.03 SUBMITTALS 1.04 QUALITY ASSURANCE

INDEX. 1.1 Main Features Environmental Conditions and Power Requirement Optional Accessories Tyre-Killer Main Parts...

A. AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) 101: Appendix Dissimilar Materials.

SECTION COMMERCIAL DOOR OPERATORS OVERHEAD RSX FIRE DOOR OPERATOR

CARD ACCESS CONTROL SYSTEM

DETEX ARCHITECTURAL SPECIFICATIONS, June 2012 AO19 SERIES HEAVY DUTY LOW-ENERGY ELECTRIC SWING DOOR OPERATOR

FlexPS. Architectural & Engineering. Specification for FlexPS. Architectural/Engineering Specification for a

MAX ARM. Heavy Duty Linear Actuator for Residential / Commercial use. Super quiet Solar ready Large diameter stainless steel output shaft

csw-200 intro d u c t i o n

MacroAir AirElite HVLS Fans

SECTION P01 LIGHTING AND APPLIANCE PANELBOARDS - A-SERIES

MacroAir AirSpan HVLS Fans

17.25 (438 mm) 37.5 (953 mm) 3.5 (89 mm) 3.0 (76 mm) 28 (711 mm) or 36 (915 mm)

ARCHITECTURAL SPECIFICATIONS

SECTION AIR DOORS

SHALLOW MOUNT HYDRAULIC ROAD BLOCKER/MODEL PROTECTOR

MacroAir AirVolution HVLS Fans

User s Manual and Warranty Information for Counterweighted Chain Drive ThyssenKrupp Access

Electrical Specifications

SECTION GENERATOR PARALLELING CONTROLS

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2018

Access Control. Total Perimeter Protection Solutions from one Source

MacroAir by Blue Giant AirVolution HVLS Fans

SECTION AUTOMATIC TRANSFER SWITCHES

Installation Instructions. CAR COMING Pedestrian Alert Safety Signs (PASS)

SECTION Overhead Coiling Doors

Outline Specification: EDSUKMT1 MAN TRAP CYLI NDER GATE

CP1-C5 COMPACTOR SPECS 2009

Section 1 General Description

Guide Specifications. HyperPod System PART 1 - GENERAL 1.01 SUMMARY

Construction Standards Page

ARCHITECTURAL SPECIFICATIONS

DIVISION 8 OPENINGS SECTION OVERHEAD COILING FIRE DOORS. A. Section Metal Fabrications: Support framing and framed opening.

SECTION GAS-FIRED RADIANT HEATERS

SlimStile BA. Tripod Turnstile for Internal Installation (*)

Architectural and Engineering Specification for a Hybrid Perimeter Intrusion Detection and Intelligent Lighting System.

Installation Instructions

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

EcoAisle Thermal Containment System

SECTION INTRUSION DETECTION

5900 SERIES Low Energy Power Operator

Architectural and Engineering Specification for a Fence-Mounted Perimeter Intrusion Detection System. FlexZone

CarSense 303 O P E R A T I N G I N S T R U C T I O N S M A G N E T O R E S I T I V E V E H I C L E D E T E C T O R

In N/C the SpeedStile provides a closed walkway and will only open on acceptance of an authorised signal.

PART GENERAL 1.01 SECTION INCLUDES

ES860 OPTICAL TURNSTILE INSTALLATION AND OPERATION MANUAL PRESENT CARD

4040 FM 535 F :

SpeedStile FP. Full-Panel Speed Gate with Sliding Glass Barrier

Bi-Directional Barrier Arm Turnstile

RCR-REX Request-to-Exit Dual Technology Motion Sensor Installation Guide

S PEEDS TILE FP. DS series. Operation & Maintenance Manual

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings.

Operating Instructions

Integrated Security Solutions

SECTION INCLINE WHEELCHAIR LIFTS. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

SECTION HVAC Fans

Paradox Integration Module Settings Guide

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL

SIA/IAPSC CAD Security Symbols

SECTION ELECTRIC TRACTION ELEVATORS PART 1 GENERAL 1.01 SUMMARY. A. Section Includes: Electric Traction Elevators.

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING GPX Builders Series Temperature Rise Door Framing

Process Protection. MFA 4P Motion Failure Alarm

Product Specifications Dialog Room Controller* (*patent pending)

SECTION HVAC Fans

SPEED FLEX HIGH SPEED FOLD UP DOORS

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING GPX Builders Series Fire Protective

MVP-D-TEK Vehicle Loop Detector 9 Volts DC to 240 Volts AC. Operating Instructions

Technical documentation

TPW-900ETS01. Product Manual. Intelligent Swing Gate Turnstile

Custom options such as housing finishes and design, lid have their presence felt. A combination of sleek, sophisticated

Access CONTROL. MANAGEMENT Software

15900 HVAC INSTRUMENTATION AND CONTROLS

GRADE CROSSING SIGNAL SYSTEM SAFETY REGULATIONS

SECTION LOW VOLTAGE POWER PANELBOARDS - SPECTRA

The following modes can be set when the units are installed, and/or can be changed later through use of a push button on the desktop controller:

ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS

2 equally Round sliding door systems with always 2 automatically half round-sliding doors

ACTIVE INFRARED BARRIER

Electromechanical Tripod Turnstile T-5

SECTION HVAC Fans

SIMPLY THE WIDEST FOLDING DOOR. FFT FLEX Green. Maximum clear opening widths and best thermal separation.

SECTION AUTOMATIC TRANSFER SWITCHES

Pole Mounting System Installation & Certification Manual

oem OEM 1" Between the Glass Metal Blind Series P2100 Included:

SECTION HVAC Fans

WALL MOUNT ELECTRIC FIREPLACE OWNERS MANUAL

Sensing the World. When you have finished this lecture you should be able to:

CEN/TC 33 - Doors, windows, shutters, building hardware and curtain walling. EN 107:1980 Methods of testing windows - Mechanical test 89/106/EEC

SECTION FAN COIL UNITS

Installation Manual Universal Top-of-Pole Mount UNI-TP/02

SECTION WATER-SOURCE UNITARY HEAT PUMPS

ELSEMA MD2010. Application Controls automatic doors or gates when a vehicle is present. Description

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

Transcription:

BL41 Extra-long Barrier NAM-BL41-ES-EN-A 1/8g

ENGINEERING SPECIFICATIONS BL41 Extra-long Barrier PART I GENERAL SECTION 08 34 56 Security Gates SECTION 11 12 33 Parking Gates SECTION 28 13 00 Access Control SECTION 34 71 13 Vehicle Barriers 1.01 SECTION INCLUDES This section covers the furnishing and installation of an extra-long barrier. 1.02 REFERENCES A. The extra-long barrier must be evaluated and approved per CAN / CSA requirements contained in SPE-1000, Model Code for the Field Evaluation of Electrical Equipment. 1.03 SYSTEM REQUIREMENTS A. The extra-long barrier must control and restrict vehicle traffic between secured and unsecured zones. B. Must feature extra-long arm to block vehicle and prevent access to restricted areas without authorization. C. Must be possible to mechanically lock in the vertical (up position) and in the horizontal (down position). D. Must be able to automatically operate and must be bidirectional, allowing traffic in both directions. E. Must be configurable in one of three (3) states: 1. Open - arm remains in the open or up position. 2. Closed - arm remains in the closed or down position. 3. Automatic - arm is normally in the closed position and controlled by the associated entry/exit hardware. F. Must be able to use the access control system to grant or deny access to the facility and operate with a variety of user authentication devices such as card reader devices, ticketing systems or barcode reader systems. G. Must be able to manually raise and lower the gate. H. Bottom of arm can be provided with safety edge to prevent arm from closing on a vehicle. I. Design of the unit must provide visual aid for intuitive process. NAM-BL41-ES-EN-A 2/8g

1.04 SUBMITTALS A. Submit product data: equipment description, dimensions, electrical wiring diagrams for installation, and manufacturer's technical manuals on each product to be used, including: 1. Preparation instructions and recommendations. 2. Storage and handling requirements and recommendations. 3. Installation methods. 4. Operation and maintenance manuals. B. Provide shop drawings and indicate component connections, anchoring methods and installation details. 1.05 DELIVERY, STORAGE AND HANDLING A. Deliver equipment to job site in manufacturer s packaging undamaged, and with complete installation instructions. B. Store indoors in a controlled environment, protected from construction activities and debris. 1.06 PROJECT/SITE CONDITIONS A. Install the extra-long barrier on leveled concrete base. 1.07 QUALITY ASSURANCE A. The extra-long barrier must be manufactured in North America. B. Manufacturer Qualifications: 1. Manufacturer must be a company specialized in designing and manufacturing extra-long barriers with a proven minimum experience of ten (10) years. C. Source Limitations: obtain the extra-long barriers from Automatic Systems. 1.08 WARRANTY A. Automatic Systems warranties its products against parts defects for a period of one (1) year from the date of invoicing. This warranty excludes normal wear on finishes or damage that occurs due to abuse or misuse. Obtain full warranty terms from Automatic Systems. NAM-BL41-ES-EN-A 3/8g

PART II PRODUCTS 2.01 MANUFACTURERS A. Manufacturers: subject to compliance with requirements, provide products by the following: 1. AUTOMATIC SYSTEMS AMERICA INC, 4005 Matte Boulevard, Unit D, Brossard, Quebec, J4Y 2P4, CANADA Phone : 800 263 6548 Fax : 450 659 0966 Homepage : www.automatic-systems.com E-mail : sales@automatic-systems.com B. Products: 1. Extra-long barrier, Model BL41 2.02 CONSTRUCTION A. Operator frame 1. Frame must be manufactured from 1/8 to 5/16 in. (3 mm to 8 mm) thick steel, corrosionprotected by zinc coating and polyester paint (standard color: orange RAL 2000), B. Access panels 1. The top and side panels must be removable to allow easy access to both the electromechanical drive and electronic control units 2. Openings must be key-locked C. Arm 1. Center mounted arm, 2. Round and manufactured from aluminum (from 19.7 ft to 39.4 ft / 6m to 12m), painted white with red reflective strips, 3. The arm is composed of up to 3 segments of 3.93in, 3.52in and 3.29 in. (100-90-84 mm) depending on length, 4. The arm is braced by galvanized steel cables for lengths of 23.1 ft (7m) and over D. Enclosure 1. Design of the unit s enclosure must ensure an IP 44 degree of protection. 2.03 DIMENSIONS A. Arm length: 1. The arm length for equipment must be 19.7 ft to 39.4 ft (6m to 10m) B. Operator dimensions: 1. Overall dimensions of BL41 operator: a. Height: 48 ¼ in (1225mm) b. Footprint: 19 ½ in x 19 ½ in (498mm x 498mm ) 2. Rotation axis height a. 37 ¼ in (948mm) NAM-BL41-ES-EN-A 4/8g

2.04 OPERATION A. Automatic mode (arm Normally Closed & Controlled by a loop or access control device): 1. In stand-by position, the passageway must be blocked by the arm. 2. Upon receipt of a signal from the access control system or the inductive loop, the arm must open, freeing the passageway. 3. The obstacle immediately closes after passage or after a configurable delay. B. Power Failure 1. In case of power failure, the barrier can open/close manually (unless equipped with the mechanical lock in power failure). 2. After the power has been restored, the unit must return to its previous operating mode. C. Emergency Operation 1. The unit can be set to remain open upon receiving an emergency signal. The obstacle opens and allows unobstructed entry / exit. 2. This operating mode continues as long as the emergency signal is active. 3. After the emergency signal has been turned off, the unit must return to its previous operating mode. 2.05 SECURITY A. Must provide operator and arm to securely block the passageway. B. Must be possible to integrate a locking device that mechanically locks the arm in the closed position to prevent any attempted break-in. C. The cabinet s side panels and top cover must be key-locked. 2.06 SAFETY A. In case of emergency or power failure, the operator must have a manual lever for unlocking the arm B. Must provide minimum 10 ft (3m) wide passageway. C. Passage can be monitored in both directions by means of a loop detector, infrared beams, safety edge or other means of monitoring, to ensure user safety and prevent arm from closing when a vehicle is passing the barrier: 1. If a presence is detected in the obstacle safety area during the opening motion, the arm will complete its opening, unless a stop command is issued. 2. If a presence is detected in the safety area during a closing motion, the arm can be set to either immediately stop or re-open, depending on the selected mode. The obstacle will operate again after the safety zone has been cleared. D. An entrapment protection device must be provided with the arm controller motor to automatically reverse or stop the movement whenever the arm strikes an object during a closing action. 2.07 VEHICLE GUIDANCE A. Visual notification with clear graphics must be incorporated into each passageway (one for each direction) to control flow and to warn users. NAM-BL41-ES-EN-A 5/8g

2.08 DRIVE UNIT A. Three-phase asynchronous geared motor combined with gear and sprocket. B. Variable-speed controller ensuring progressive accelerations and gradual decelerations, for safe movement without vibrations. C. Electronic torque limitation. 2.09 CONTROLLER A. Microprocessor-based controller with the following characteristics: 1. The logic must be equipped with: a. Digital screen to facilitate the configuration of the barrier, b. LED indicators showing the status of the inputs and outputs, c. 1 analog and 14 digital inputs, d. 3 output relays, 4 digital outputs and 1 analog output. 2. The logic must be equipped with two (2) loop detector connectors when loops are used as safety or to control the barrier opening/closing. 3. The barrier operator may be equipped with an optional extension module that adds 4 inputs and 4 outputs. 2.10 POWER SUPPLY A. Power supply: 120 Volts AC 60 Hz B. Nominal power consumption: 1. At rest: 50W 2. In operation: 450W 2.11 PERFORMANCE A. Opening Time & Closing Time: 1. The obstacle opening time: 3.5 seconds (adjustable through the control board) 2. The obstacle closing time: 5.5 seconds (adjustable through the control board) B. MCBF: 1.250.000 average number of cycles between breakdowns, when respecting manufacturer s recommended maintenance. C. Operating Temperatures: -4 to 122 F (-20 to 50 C) without heater. NAM-BL41-ES-EN-A 6/8g

2.12 OPTIONAL EQUIPMENT ** NOTE TO SPECIFIER ** Delete the following subparagraphs in brackets if no optional equipment is required, or add as necessary. 1. [Automatic opening of the arm during power failure] 2. [Mechanical locking of the arm in opened and/or closed position upon power failure] 3. [Push button(s) box] 4. [Key switch on housing] 5. [Command by radio transmitter/receiver] 6. [Inductive loops for car or truck detection] 7. [Presence detector]. 8. [Photo electric cell (automatic opening, closing, safety) fixed on post or housing] 9. [Folding tip support] 10. [Electro-magnetic tip support] 11. [Safety edge] 12. [Arm lighting] 13. [Traffic lights fixed on a post or housing] 14. [STOP traffic sign] 15. [250 W heater for operation in temperatures as low as -13 F (-25 C) ] 16. [400 W heater for operation in temperatures as low as -49 F (-45 C) ] 17. [Raised base] 18. [Rotating base] 19. [Insulation anti-corrosion base) 20. [Non standard color] 21. [Optional I/O board] 22. [Traffic light optional board for third party traffic signs] 23. [Arm offset with stirrup increasing stiffness of the arm shaft] NAM-BL41-ES-EN-A 7/8g

PART III EXECUTION 3.01 INSPECTION A. Installer must examine the installation location and advise the Contractor of any site conditions inconsistent with proper installation of the product. These conditions include but are not limited to the following: 1. Extra-long barrier operator must be installed on a level concrete pad, 2. Power supply and control wiring must be installed. Follow manufacturer s recommendations. B. Proceed with installation only after unsatisfactory conditions have been corrected. 3.02 INSTALLATION A. Install extra-long barrier in strict accordance with manufacturer s instructions. Set units level. Anchor securely into place. 3.03 ADJUSTMENT A. Installer must adjust extra-long barrier for proper performance after installation. 3.04 INSTRUCTION A. A factory trained installer must demonstrate to the owner s maintenance crew the proper operation and the necessary service requirements of the equipment, including exterior maintenance. 3.05 CLEANING A. Clean barrier operator and area carefully after installation to remove excess caulk, dirt and labels. 3.06 MAINTENANCE A. Maintain the equipment according to the manufacturer s instructions. Automatic Systems reserves the right to change this specification at any time without notice. END OF SECTION NAM-BL41-ES-EN-A 8/8g