RLNI with P/N _J NSF. INNOVATOR Doors or. INNOVATOR III Doors. Certified. Technical Data Sheet. January 2018

Similar documents
RLTIM with P/N _H NSF INNOVATOR. Certified. & INNOVATOR III Doors Technical Data Sheet. January 2018

Engineering Plan Views

RL with INNOVATOR II No Heat Doors

RM with INNOVATOR Doors

RLNIE with INNOVATOR II

Freedom Line RFLN. Certified. with INNOVATOR Doors. or INNOVATOR III Doors Low Temperature Technical Data Sheet P/N _J NSF

RLT with INNOVATOR Doors

RLNIE P/N G. P/N _G NSF Certified. Technical Data Sheet. Warning: Terminal block NOT for case-to-case wire connection!

Freedom Line RFM. Certified. with INNOVATOR Doors. Medium Temperature Technical Data Sheet P/N _B NSF. Freedom Line merchandisers are top mount

FIG-L P/N _F NSF. Certified January 2018 H C A L B. Technical Data Sheet

LifeLine Premier RLNIE

FWEL P/N _D NSF E D C H B A F. Certified January Technical Data Sheet. Item Part # Description Wiring Item #

P/N _K NSF. Certified. Technical Data Sheet. March Spanish P/N Item Part # Description Wiring Item #

F-L P/N _C NSF. Certified C A. Technical Data Sheet. March Item Part # Description Wiring Item # Item Part # Description Wiring Item #

FG-L P/N _C NSF. Certified. Technical Data Sheet. March 2017 H C K B. Item Part # Description Wiring Item #

FIG P/N _K NSF. Certified March 2017 J A F E B I. Technical Data Sheet. Spanish P/N

RMN with INNOVATOR Doors Technical Data Sheet

P/N _F NSF Certified June 2010

Freedom Line RFMN. Certified. with INNOVATOR Doors Medium Temperature Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount

Freedom Line RFLNS. Certified. with INNOVATOR Doors. Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount.

FG-L Technical Data Sheet

P1NX-E P/N _G NSF. Certified. Technical Data Sheet. October 2016

FWG-L. Certified. DOE 2012 Energy Efficiency Compliant. Technical Data Sheet P/N _D NSF. May Spanish

FWG P/N _M NSF. Certified. DOE 2012 Energy Efficiency Compliant F J G I. Technical Data Sheet. June Data sheet-excel FWG.

PWWEE P/N _C NSF. Certified. Technical Data Sheet. October 2016

FWG P/N _G. NSF Certified December Technical Data Sheet F J G I P/N _G. Item Part # Description Wiring Item #

PWEE Technical Data Sheet

M1GLE-93. P/N _G NSF Certified A E P/N F. Technical Data Sheet. July Item Part # Description Wiring Item #

P/N _D NSF. Certified. Frozen. May Merchandiser Data Sheet

Excel FWGH P/N _F NSF. Certified. Frozen. January Merchandiser Data Sheet

Freedom Line RFMNS. Certified. with INNOVATOR Doors. Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount.

LNG P/N _H. NSF Certified February 2007 C A F G H. Technical Data Sheet P/N _H. Item Part # Description Wiring Item #

EXCEL FWEGH-L P/N _F NSF. Certifi ed. Frozen. March Merchandiser Data Sheet

P/N _G. NSF Certified February 2007 C A F G H. Technical Data Sheet P/N _G. Item Part # Description Wiring Item #

EXCEL FWEGH P/N _D NSF. Certifi ed. Frozen. March Merchandiser Data Sheet

P/N _D NSF. Certified. Frozen. May Merchandiser Data Sheet

BEXD-8A. Certified. Spanish P/N Technical Data Sheet P/N _C NSF. March 2017

Nosing Heater. Return Grill Heater

RL with INNOVATOR Doors

LWU Technical Data Sheet

BEXD-8A. P/N _A NSF Certified P/N_ _A C B P E D K. Technical Data Sheet. November 2010

Reach-in Merchandisers

OPTIONAL MOTION ACTIVATED LED DIMMER CONTROL

FIELD-INSTALLED MOTION ACTIVATED LED DIMMER CONTROL

JUMBO ISLAND FROZEN FOOD/ICE CREAM/MEDIUM TEMP MERCHANDISERS Low, Medium and Dual Temperature Self Serve Display Cases

OPTIONAL CONTROLLER. Kit P/N _A. December 2016 ANTI-CONDENSATE HEATER FOR REACH-IN GLASS DOORS. Spanish French

Installation & Service Manual

Installation & Service Manual

ISF and ISM. Low and Medium Temperature Remote and Self Contained Island Merchandisers. Installation & Service Manual IMPORTANT

MD Medium Temperature Self Contained Open Vertical Merchandisers

Medium Temperature. Installation & Operation Manual Shipped With Case Data Sheets. IMPORTANT Keep in store for

NFW, NCW, NFWG, NCWG, NFWE, NCWE

L3MGB. THREE DECK MEAT/DELI MERCHANDISERS Medium Temperature Self Serve Display Cases

P/N _B September Field Installed Dual Temp Operation E P R Controlled (Evaporator Pressure Regulator)

Low Temperature. Installation & Operation Manual IMPORTANT. Single Deck Wall & Island Merchandisers. Keep in store for future reference!

Medium Temperature. Installation & Operation Manual Shipped With Case Data Sheets. IMPORTANT Keep in store for future reference!

6RZLH 6RZLH. Reach-In Merchandiser 2, 3, 4 & 5 Door (Frozen Food) REFERENCE NOTES FOR ENGINEERING DATA

EcoShine II Horizontal LEDs for Multi-Deck Merchandisers Shelf, Rail and Canopy

EcoVision Door Manual

RFLNS, RFMNS & RFLTM Freedom Line

Medium Temperature Bulk Produce and Bakery Merchandisers

Installation & Service Manual

Installation & Service Manual

GSVM Medium Temperature Self Contained Open Vertical Merchandisers. Installation & Service Manual

MD Medium Temperature Self Contained Open Vertical Merchandisers

F-6 Multi-deck Frozen Food Wall Merchandisers

ON3.5EM-NRG ON3.5EM-NRG. Narrow Multi-Deck Merchandiser with Synerg-E End Cap (Dairy/Deli/Meat/Produce) SHIPPING WEIGHT GENERAL NOTES:

SSGB. EPH Certified to NSF-7 G B. Technical Data Sheet P/N _E. January Data sheet-excel SSGB

L6FA. MULTI-SHELF FROZEN FOOD MERCHANDISER Low Temperature Self Serve Display Cases

BCH Medium Temperature Merchandisers

HGL- 1, 2 & 3 BS, TS. Bottom / Top Mount Low Temperature Remote and Self Contained Glass Door Merchandisers. Installation & Service Manual IMPORTANT

ON4UM-NRG ON4UM-NRG. Narrow Multi-Deck Merchandiser 4', 6', 8', 12' (Dairy/Deli/Produce) SHIPPING WEIGHT GENERAL NOTES

OHMH-NRG OHMH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT GENERAL NOTES

Service Merchandisers

O3UM-NRG O3UM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8', 10', 12' (Dairy/Deli/Meat/Produce) SHIPPING WEIGHT

6DMLH-NRG 6DMLH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Beverage / Dairy / Deli / Produce) SHIPPING WEIGHT GENERAL NOTES

KR Electrical Defrost Unit Coolers (PN E108318_E)

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE

HGM-1, 2 & 3 BS, TS. Bottom / Top Mount Medium Temperature Remote and Self Contained. Installation & Service Manual. Glass Door Merchandisers

RFLN & RFMN Freedom Line

Self-Contained MERCHANDISERS. February

Installation & Service Manual

O5MH-NRG O5MH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT

Rear Roll-in Dairy Medium Temperature Free Standing or Suspended Merchandisers Installed in Walk-in Cooler Exterior Walls

& MAINTENANCE INSTRUCTIONS INSTALLATION, OPERATION INDUSTRIAL COOLERS & FREEZERS WALK-IN COOLERS SERIES: EK, EM, EH, EI, EB, EF

4A6H5049E1000B 208/230/1/ /8 7/8 7/8 7/8 DURATION 208/230/1/ /230/1/ SPINE FIN 13 LBS., 10 OZ. YES

208/230/1/60 5/8 5/8 5/8 5/8 5/8 20 CLIMATUFF /230/1/

O4ID O4ID. Medium Temp Island Merchandiser 8' & 12' (Deli / Meat) ENGINEERING REFERENCE SHEET NOTES

O5M-NRG O5M-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT GENERAL NOTES

EcoVision II Plus Door Upgrade for D6 Kysor Warren Multi-deck Merchandisers

Ultra Low Front Rear Load Medium Temperature

O5DM-NRG O5DM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Beverage / Dairy / Deli / Produce) SHIPPING WEIGHT Case Weight O5DM-NRG ---

Commercial High-Efficiency Condensing Units

Hoshizaki America, Inc.

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS WALK-IN COOLERS SERIES LS-LP-LA-LV

SERIES NAV S Display Merchandisers

Parallel Rack Systems

KRSCP Self-Contained Walk-In Unit Installation and Service Manual Addendum

Horizon Elite Ice Machine Installation Instructions for Remote Condensing Unit

VNRZH VNRZH. High Narrow Reach-In Merchandiser 1, 2, 3, 4, & 5 Door (Frozen Food) SHIPPING WEIGHT Case Weight VNRZH LBs GENERAL NOTES

Transcription:

RLNI with INNOVATOR Doors or Serial Plate INNOVATOR III Doors NS Certified January 2018 We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped. ront Warning: Terminal block NOT for case-to-case wire connection! Item Part # Description Wiring Item # an Assemblies, and Thermostats A. 12W Standard Energy Efficient an Assembly (1) 0477655 an Motor, Evaporator (MO.4410546) 0461805 an Blade (B.4780446) B. 0474033 Standard Non-adjustable (2) Defrost Thermostat (CT.4440726) C. Optional Adjustable Refrigeration Thermostat (3) D. 0344662 Defrost Limit Thermostat (4) (CT.4440261) E. 0461814 Relay Control Thermostat or (5) an and Anti-sweat Heater Thermostat (CT.4481296) (KG Only) Relays. 0342598 Anti-Sweat Control Relay (120V) (6) (120V KoolGas) (RL.4480238) G. 0342599 an Control Relay (208V) (7) (RL.4480237) Item Part # (Qty.) Description Wiring Item # Heaters H. Electric Defrost Heaters ront (208V) (8) 3015372 (1) 2 Door Models (HE.4850346) 3015373 (1) 3 Door Models (HE.4850337) 3015374 (1) 4 Door Models (HE.4850347) 3015375 (1) 5 Door Models (HE.4850323) Electric Defrost Heaters Rear (208V) (8) 3015376 (1) 2 Door Models (HE.4850358) 3015377 (1) 3 Door Models (HE.4850359) 3015378 (1) 4 Door Models (HE.4850360) 3015379 (1) 5 Door Models (HE.4850361) I. Drain Pan Heater (Electric & KoolGas) (9) (120V) 0387036 (1) 2 Door Models (HE.4850239) 0387037 (1) 3 Door Models (HE.4850240) 0387038 (1) 4 Door Models (HE.4850241) 0387039 (1) 5 Door Models (HE.4850242) LED ixtures and Power Supply J. 0499399 LED Power Supply (EP.4481668) K. LED ixture Replace with like fixtures Refer to Innovator Reach-In Glass Door Installation and Service manual, P/N 0425683, for Innovator, Innovator II, and Innovator III door and frame replacement parts. Data sheet-reach-in RLNI Note: Revision J: Updated wiring diagrams on page 6 and 7. 2018 HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 MEXICO 1-800-890-2900 WWW.HUSSMANN.COM Spanish P/N 0553995

Engineering Plan Views RLNI Plan View 2, 3, 4, & 5 Door Dimensions shown as in. & (mm). PHYSICAL DATA Merchandiser Drip Pipe (in.) 1 1 /4 Merchandiser Liquid Line (in.) 3 /8 Merchandiser Suction Line (in.) 5 /8 Door Swing Rear Relay & Terminal Block Location Refrig. Outlet Electrical Wireway Skid/ External Base Bottom ront Support Electrical Wireway Waste Outlet Splashguard Refrig. Outlet ront Relay & Terminal Block Location Door Swing ront 5-Door Shown Serial Plate attached to top left front of each case. 2 Dr 3 Dr 4 Dr 5 Dr General (A) Case Length (without ends or partitions) 62 (1575) 92 1 /2 (2350) 122 7 /8 (3121) 153 3 /8 (3896) **NOTE: Each solid end adds approximately 2 3 /8 in (60 mm) to length of line up; each partition add approximately 2 3 /4 in (70 mm); case to case joints can add approximately 1 /8 in (3 mm) for gasket material. Maximum O/S dimension of case back to front 72 3 /8 (1837) 72 3 /8 (1837) 72 3 /8 (1837) 72 3 /8 (1837) (Includes bumper) Back of case to rear of splashguard 68 1 /2 (1740) 68 1 /2 (1740) 68 1 /2 (1740) 68 1 /2 (1740) Width of Skidrail 3 3 /4 (95) 3 3 /4 (95) 3 3 /4 (95) 3 3 /4 (95) Width of Bottom ront Support 6 (152) 6 (152) 6 (152) 6 (152) Stub-up area between front skidrail and splashguard 9 (229) 9 (229) 9 (229) 9 (229) Electrical Service RH end of case to the center of nearest knockout 4 (102) 4 (102) 4 (102) 4 (102) RH end of case to the center of LH knockout 58 (1473) 88 1 /2 (2248) 118 7 /8 (3019) 149 3 /8 (3794) Back O/S of case to center of knockout 70 1 /8 (1781) 70 1 /8 (1781) 70 1 /8 (1781) 70 1 /8 (17810) * NOTE: Electrical ield Wiring Connection Point is at terminal. Waste Outlet (B) Right end of case to center of waste outlet 23 7 /8 (606) 54 1 /4 (1378) 46 1 /4 (1175) 76 5 /8 (1946) Back O/S of case to center of waste outlet 63 1 /4 (1607) 63 1 /4 (1607) 63 1 /4 (1607) 63 1 /4 (1607) Water Seal Edge of water seal to center of waste outlet 13 (330) 13 (330) 13 (330) 13 (330) Schedule 40 drip piping 1 1 /4 (32) 1 1 /4 (32) 1 1 /4 (32) 1 1 /4 (32) ** NOTE: ield installed water seal outlets, tees, and connectors are shipped with case Refrigeration Outlet RH end of case to center of RH refrigeration outlet 5 5 /8 (143) 5 5 /8 (143) 5 5 /8 (143) 5 5 /8 (143) Back O/S of case to center of refrigeration outlet 60 5 /8 (1541) 60 5 /8 (1541) 60 5 /8 (1541) 60 5 /8 (1541) Outside bottom front supports from end of case 7 (178) 7 (178) 7 (178) 7 (178) Center bottom front support from Centerline 24 (610) 24 (610) 24 (610) 24 (610) Distance between Center and Outside supports will vary 2 of 7 U.S. & CANADA 1-800-922-1919 MEXICO 1-800-890-2900 RLNI with Innovator Doors or Innovator III Doors

Reach-in Narrow Island 2, 3, 4 and 5 Door Models INNOVATOR Doors Standard RLNI, RLNIE rame Door Hussmann refrigerated merchandisers configured for sale for use in the United States meet or surpass the requirements of the DOE 2017 energy efficiency standards. Standard Reach-in configuration consists of Innovator I doors, energy efficient fan motors, and EcoShine II LED vertical lighting. Dimensions shown as in. & (mm). Shelf RLNI With Innovator Doors or Innovator III Doors Refrigeration data is PER SIDE. RERIGERATION DATA Note: This data is based on store temperature and humidity that does not exceed 75 and 55% R.H. IC AHRI Rating* Discharge Air ( ) 5 12 2 Evaporator ( ) 11 19 7 Unit Sizing ( ) 14 22 10 *With A/S controller. Btu/hr/door/side Innovator I Parallel 865 970 840 Conventional 880 990 855 Innovator III Parallel 815 940 Conventional 830 960 Average evaporator temperature shown. Use dew point for high glide refrigerants for unit sizing. Care should be taken to use the dew point in PT tables for measuring and adjusting superheat. Adjust evaporator pressure as needed to maintain discharge air temperature shown. rame Electrical ield Wiring Connection is at Terminal Refrigeration Outlet an Coil Refrigeration Outlet Coil an Electrical Stub-up Area DEROST DATA IC requency (hr) 24 24 Defrost Water (lb/dr/side/day) 1.2 1.2 (± 15% based on case configuration and product loading). Electric IC Temp Term ( ) 48 48 ailsafe (minutes) 45 45 Electrical Stub-up Area Gas Duration (minutes) 20 20 Offtime Not Recommended Estimated Charge Per Side*** 2Dr 1.8 lb 29 oz 0.8 kg 3Dr 2.7 lb 43 oz 1.2 kg 4Dr 3.6 lb 58 oz 1.6 kg 5Dr 4.6 lb 74 oz 2.1 kg ***This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound (8 oz/0.2 kg). NS Certification This merchandiser model is manufactured to meet NS/ANSI (National Sanitation oundation) Standard #7 requirements for construction, materials & cleanability. CONVENTIONAL CONTROLS Low Pressure Backup Control IC CI/CO (Temp )* 18 / 34 26 / 45 Indoor Unit Only, Pressure Defrost Termination (Temp )** Not Recommended **Use a Temperature Pressure Chart to determine PSIG conversions. HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. WWW.HUSSMANN.COM 3 of 7

RLNI With Innovator Doors or Innovator III Doors Hussmann recommends against frame heater cycling with Innovator doors or Innovator III doors to prevent door seals from freezing to the frames and tearing. Electrical Data ELECTRICAL DATA IS PER SIDE TWO CIRCUITS REQUIRED PER CASE. 2Dr 3Dr 4Dr 5Dr Number of ans 12W 2 3 4 5 Amperes Watts Merchandiser 2Dr 3Dr 4Dr 5Dr 2Dr 3Dr 4Dr 5Dr Energy Efficient Evaporator an 120V 50/60Hz 0.60 0.90 1.20 1.50 36 54 72 90 240V 50/60Hz Export Innovator 0.30 0.45 0.60 0.75 36 54 72 90 Door Anti-sweat Heaters (on fan circuit) 120V 50/60Hz Innovator* 1.5 2.3 3.0 3.8 182 273 364 455 120V 50/60Hz Innovator III 0.9 1.3 1.7 2.2 104 156 208 260 240V 50/60Hz Export Innovator 0.8 1.2 1.5 1.9 183 275 367 459 220V 50/60Hz Export Innovator III NA NA NA NA NA NA NA NA * Maximum door watts without anti-sweat cycling controls shown. rame Anti-sweat Heaters (on fan circuit) 120V 50/60Hz 0.78 1.18 1.57 1.97 94 141 188 236 240V 50/60Hz Export 0.45 0.67 0.89 1.12 107 161 215 269 Minimum an Circuit Ampacity 120V 50/60Hz Innovator 3.1 4.9 6.8 8.6 120V 50/60Hz Innovator III 2.5 3.9 5.5 7.0 240V 50/60Hz Export Innovator 1.8 2.9 4.0 4.9 240V 50/60Hz Export Innovator III 1.0 1.6 2.3 2.8 Maximum Over Current Protection 120V 20 20 20 20 Maximum Over Current Protection 240V 15 15 15 15 Defrost Drain Heaters (120V) 0.63 1.25 2.00 2.57 75 150 240 300 (Export: 220V 50 Hz) 0.34 0.76 1.22 1.53 84 168 269 336 (Export: 240V 50 Hz) 0.41 0.83 1.33 1.67 100 200 320 400 208V 1Ø Electric Defrost 6.72 10.08 13.46 16.82 1400 2100 2800 3500 (Export: 220V 50 Hz) 7.11 10.66 14.24 17.79 1564 2345 3133 3914 (Export: 240V 50 Hz) 7.76 11.65 15.53 19.42 1864 2796 3728 4660 Standard Vertical LED Lighting 2Dr 3Dr 4Dr 5Dr 2Dr 3Dr 4Dr 5Dr Hussmann EcoShine II (120V) 0.36 0.54 0.72 0.90 38 57 76 95 Hussmann EcoShine II (220V Export) 0.20 0.29 0.39 0.49 38 57 76 95 Optional Vertical LED Lighting GE Illumination (120V) 0.30 0.45 0.60 0.75 36 54 72 90 GE Illumination (220V Export) 0.16 0.25 0.33 0.41 36 54 72 90 Anti-sweat controls are standard for all low temperature Reach-in cases with Innovator I doors. 4 of 7 U.S. & CANADA 1-800-922-1919 MEXICO 1-800-890-2900 RLNI with Innovator Doors or Innovator III Doors

Product data is PER SIDE. RLNI With Innovator Doors or Innovator III Doors Product Data Recommended Usable Cube 1 (Cu t/dr) AHRI Total Display Area 2 (Sq t/dr) Shelf Area 3 (Sq t/dr) 22.80 ft 3 /Dr (0.65 m 3 /Dr) 13.04 ft 2 /Dr (1.21 m 2 /Dr) 28.50 ft 2 /Dr (2.65 m 2 /Dr) 1 AHRI Refrigerated Volume less shelving and other unusable space: Refrigerated Volume/Unit of Length, ft 3 /ft [m 3 /m] 2 Computed using AHRI 1200 standard methodology: Total Display Area, ft 2 [m 2 ]/Unit of Length, ft [m] 3 Shelf surface area is composed of bottom deck plus standard shelf complement, as shown in the Hussmann Product Reference Guide. The standard shelf complement for this model is (5) rows of 22-inch shelves. ESTIMATED SHIPPING WEIGHT 4 Case Solid End 1 Dr 2 Dr 3 Dr 4 Dr 5 Dr (each) lb (kg) NA (NA) 1144 (520) 2230 (1014) 2974 (1352) 3718 (1690) 110 (50) 4 Actual weights will vary according to optional kits included. HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. WWW.HUSSMANN.COM 5 of 7

an and Heater Circuits - Electric Defrost (standard) CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS R = Red P = Purple 2P = Purple (2 Bands) DB = Dark Blue BK = Black LB = Light Blue BR = Brown Y = Yellow OR = Orange W = White THESE ARE MARKER COLORS (WIRE MAY VARY.) 208 V 208 V 1 2 3 ANS 120 V 14 REAR DEROST RONT DEROST AN RELAY NC COM NO AN RELAY COIL 8 7 6 ANS 16 LINE 7 8 7 DEROST LIMIT O.O.R. ROD HEATER (DRAIN) 9 1 4 4 5 ANS 26 25 24 CAUTION: When multiplexing merchandisers equipped with defrost heaters, if branch circuit overcurrent protection is larger than the individual merchandiser s defrost circuit load, then additional supplemental overcurrent protection may be required per NEC Articles 210 and 240. Refer to Innovator Reach-In Glass Door, Installation and Service manual, P/N 0425683, for Innovator door and frame replacement parts. 13 HEATER RAME A.S. 22 DOOR A.S. 12 21 (120 V) () 17 SWITCH L 20 3024448_C IELD WIRED DEROST TERMINATION THERMOSTAT C.O.R. THE HEAVY LINES DRAWN INSIDE THE TERMINAL BLOCKS REPRESENT PERMANENT INTERNAL JUMPERS. 1 2 3 4 5 6 7 8 10 11 12 13 14 16 17 20 21 22 24 25 26 DEROST HEATERS (208V) DEROST HEATERS (208V) ANS & A/S (120V) (120V) () ANS, & A.S () THE HEAVY LINES DRAWN OUTSIDE THE TERMINAL BLOCKS REPRESENT REMOVABLE EXTERNAL JUMPERS. Electric Defrost Sequence - 1. Power from the defrost contactor energizes Defrost Heaters and 208V Evaporator an Relay Coil (7). Relay Contacts open the fan circuit and energizes the Drain Pan Heater. 2. If the Defrost Heater raises internal air temperature above 90, the Defrost Limit Thermostat (4) will open. 3. When Defrost Termination Thermostat ends defrost period, the defrost contactor opens the Defrost Heater and Evaporator an Relay Coil Circuits. The Drain Pan Heater goes off and fans are on. 4. Standard low temperature Reach In cases with Innovator I doors are shipped with the controller for door anti-sweat heater control installed. Do not connect the controller input to a centralized anti-sweat system. It must be connected to a continuous 120V circuit for proper operation. 5. If the case is connected to a centralized anti-sweat controller that meets DOE compliance requirements, the controller is not installed on the case. eed the 120V controller output into terminal #12. 6. Options may be installed that have additional or replacement wiring diagrams. 7. Reach In cases with Innovator III doors do not have the controller. 6 of 7 U.S. & CANADA 1-800-922-1919 MEXICO 1-800-890-2900 RLNI with Innovator Doors or Innovator III Doors

an and Heater Circuits - Gas Defrost (optional) CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS R = Red P = Purple 2P = Purple (2 Bands) DB = Dark Blue BK = Black LB = Light Blue BR = Brown Y = Yellow OR = Orange W = White THESE ARE MARKER COLORS (WIRE MAY VARY.) 120V 14 16 COM AN RELAY NC NO 6 1 RELAY CONTROL C.O.R. DEROST LIMIT O.O.R. ANS ROD HEATER (DRAIN) 5 6 AN RELAY COIL 26 25 24 Refer to Innovator Reach-In Glass Door, Installation and Service manual, P/N 0425683, for Innovator door and frame replacement parts. LINE 13 RAME A.S. 22 HEATER 12 DOOR A.S. 21 120V 17 SWITCH L 20 10 11 12 13 14 16 17 20 21 22 24 25 26 ANS & A.S. (120V) Gas Defrost Sequence - (120V) () ANS & A.S. () THE HEAVY LINES DRAWN INSIDE THE TERMINAL BLOCKS REPRESENT PERMANENT INTERNAL JUMPERS. THE HEAVY LINES DRAWN OUTSIDE THE TERMINAL BLOCKS REPRESENT REMOVABLE EXTERNAL JUMPERS. 3024767_C 1. Defrost vapor enters evaporator causing a rise in temperature. At about 35 the Control Relay Thermostat (5) closes the an Relay Coil (7) and Control Relay Coil (6) circuit. The Coil opens the an, Door Heater, and rame Heater circuits, while energizing the Drain Pan Heater (9). 2. If the Drain Pan Heater (9) raises internal air temperature above 90, the Heater Limit Thermostat (4) will open. 3. When the defrost timer ends a defrost period, the evaporator temperature will start to fall. At about 20, the Control Relay Thermostat will open, de-energizing the Control Relay Coil and an Relay Coil (7). Control and an Relay s will open the Drain Pan Heater circuits, and will close the an, Door Heater, and rame Heater circuits. 4. Standard low temperature Reach In cases with Innovator I doors are shipped with the controller for door anti-sweat heater control installed. Do not connect the controller input to a centralized anti-sweat system. It must be connected to a continuous 120V circuit for proper operation. 5. If the case is connected to a centralized anti-sweat controller that meets DOE compliance requirements, the controller is not installed on the case. eed the 120V controller output into terminal #12. 6. Options may be installed that have additional or replacement wiring diagrams. 7. Reach In cases with Innovator III doors do not have the controller. HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. WWW.HUSSMANN.COM 7 of 7