2 Building Type. 3 Trade Ally/Contractor Information. Refrigeration Rebate Worksheet. Retrofit New Construction

Measure Guidelines. for EnergySmart Grocer (ESG)

Understanding Head Pressure Control. Walter H Langille, M.A.Sc., P.Eng Sales Engineer KeepRite Refrigeration

Small Commercial Business Energy Audits. Recognizing and addressing the special requirements of the small business market segment.

* Peak kw is determined by the average kw load reduction occurring between 1PM and 4PM on weekdays during June, July and August.

Direct Install Program Eligible Measures Listing:

Incentive & Measure Specifications

SUMMARY OF SERVICES & INCENTIVES

REFRIGERATION Open case to New Reach-in Low or Medium Temperature Low Temp Coffin to New High Efficiency Reach-In...

Focus on Energy Business Programs Summary of Services and Incentives July 2009

at a glance Energy FinAnswer Case Study: Albertsons Energy FinAnswer is the best-run, best-delivered program we ve been involved with.

Air-Cooling Evaporators

Midwest Industrial Initiative Webinar: Industrial Refrigeration

Thomas J Kelly. Fundamentals of Refrigeration. Sr. Engineering Instructor Carrier Corporation. August 20, Page number: 1.

If pre-approval is required - work with your Energy Advisor to obtain pre-approval prior to purchasing equipment.

SECTION 8 AIR SOURCE HEAT PUMPS UNIT 43 AIR SOURCE HEAT PUMPS

COMMERCIAL. Oregon Incentives

Math. The latent heat of fusion for water is 144 BTU s Per Lb. The latent heat of vaporization for water is 970 Btu s per Lb.

TrilliumSeries. Condenser

5. ASSESSMENT RECOMMENDATIONS

WCH5**4. Product Specifications

Series. Chillers and. Features: Application Flexibility Minimizes Installation Time and Reduces Cost

Equipment Efficiency Guide

Presented By: John Dolan, P.E.

COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd

Introduction. Motor Types

Low Profile Unit Coolers

RSES Technical Institute Training Manual 1 70 hours, 70 NATE CEHs, 7.2 CEUs

Instructors: Contact information. Don Reynolds Doug McGee Factory Tech Support

What You Need to Know About Refrigeration Systems

A Treatise on Liquid Subcooling

RSES Technical Institute Training Manual 2 72 hours, 72 NATE CEHs, 7.2 CEUs

Appendix A. Glossary of Common Terms

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

Trane Family of Terminal Products

Application of two hybrid control methods of expansion valves and vapor injected compression to heat pumps

Refrigeration Systems and Accessories

2018 SUMMARY OF SERVICES AND INCENTIVES

Reach-In Unit Coolers: ASL 2 Slim-Temp 2 Wedge-Temp 3 Flex-Temp 3 Mullion-Temp 3 T-Temp 4 Twin-Temp 4 Mini-Twin-Temp 4 Wall-Temp 5

AEPT SERIES PRODUCT SPECIFICATIONS. Multi-Position Air Handler. 2 to 5 Ton

OIM OIM. Medium Temp Island Merchandiser 8' & 12' (Deli / Meat) REFERENCE NOTES FOR ENGINEERING DATA:

INSTALLATION and OPERATING. INSTRUCTIONS for. SMZP26 Series. elf-contained Freezers

Calhoon MEBA Engineering School. Study Guide for Proficiency Testing Refrigeration

IMPA Energy Efficiency Program

Page ` RLP R1. Supersedes all earlier versions LIST PRICES April, 2018

AEPT SERIES PRODUCT SPECIFICATIONS. Multi-Position, Variable-Speed High-Efficiency Air Handler. 2 and 5 Ton

LOW PROFILE UNIT COOLER

Super-Flo Low Profile Unit Cooler

Greensource Residential Water Source Heat Pumps. Simply Smart. i Series: SV Model. boschheatingandcooling.com

How to Cut Chiller Energy Costs by 30%

energydesignresources

Center Mount Unit Coolers

Digi-Motor. ECM for Commercial Refrigeration. Toll Free (800) Fax (631)

Reach-In Unit Coolers: ASL 2 Slim-Temp 2 Wedge-Temp 3 Flex-Temp 3 Mullion-Temp 3 T-Temp 4 Twin-Temp 4 Mini-Twin-Temp 4 Wall-Temp 5

Chapter-8 Capacity Control of Refrigeration Systems

BASE LEVEL AUDIT REQUIREMENTS REFRIGERATION SYSTEMS 1. SITE DATA COLLECTION. Business Name. Site physical address (Street, Suburb, City)

Midea VFD Centrifugal Chiller Technology

LOW PROFILE UNIT COOLER. Technical Guide. Models RLC Air Defrost ELC/EFC Electric Defrost GLC Hot Gas Defrost. CH-LOPTB May,

INVESTIGATING THE EFFECTS OF EVAPORATOR FAN SPEED VARIATION AND THE INFILTRATION PHENOMENON IN A WALK-IN COOLER

Page ` RLP A. Supersedes all earlier versions LIST PRICES Prices effective 7/2/18

FOOD SERVICE EQUIPMENT REBATES

HIGH-EFFICIENCY EQUIPMENT TECHNICAL SHEET

RDT Refrigeration Book

SECTION 5 COMMERCIAL REFRIGERATION UNIT 21 EVAPORATORS AND THE REFRIGERATION SYSTEM UNIT OBJECTIVES 3/22/2012 REFRIGERATION

recooler HP EQKR HEAT PUMP

Fundamentals of Refrigeration p. 25 History and Fundamentals of Refrigeration Module p. 25 Development of Refrigeration p. 25 How a Mechanical

EC Fans Growing in Popularity

RLP Page. Prices effective January 1, Supersedes all earlier versions LIST PRICES

ENERGY EFFICIENT RETROFITS. Date

D-PAC. Digital Precise Air Control System. Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency

Tube-in-tube heat exchanger Type HE

HVAC Water chiller selection and optimisation of operation

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( )

RIGID DC LIQUID CHILLER

Heat Transfer Products. Product Line Update

Installation, Operation, and Maintenance Information

GLOBAL PROPERTY INSPECTIONS TECHNICAL BULLETIN August 1, 2002

i-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE:

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS UNIT OBJECTIVES UNIT OBJECTIVES 3/22/2012

Air Conditioning and process cooling Energy Components at a Glance

Installation, Operation, and Maintenance Information

R4H4. Product Specifications

Refrigeration / Air Conditioning Systems Circuit Drawings. Student Resource Package No: NR 24

On Balance: Heat Rejection Control a Packaged Solution

From the Field to the Supermarket

<<Date>> <<Recipient>> <<Address>>

O4ID O4ID. Medium Temp Island Merchandiser 8' & 12' (Deli / Meat) ENGINEERING REFERENCE SHEET NOTES

General HVAC Recommendations

Centre for Air Conditioning and Refrigeration. Retail refrigeration. Judith Evans, Ed Hammond and Alan Foster London South Bank University

Copeland Scroll. Product Information. Outdoor condensing units for refrigeration applications

Unit Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

KCS-Line Air Cooled Condensers

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

PRODUCT DESCRIPTION CONTROLS

ORTEC HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS

Optimal Use of Air Conditioner

for Refrigeration Applications

Low Profile Unit Coolers

RE: Supplement to Tariff Advice No Schedule 89 Commercial and Industrial Energy Efficiency and New Cost- Effectiveness Exceptions

Transcription:

Installation of High-Efficiency High Efficiency Evaporator Fans Evaporator Fans That have Highfor Walk-ins Efficiency Permanent Split $50/fan motor Capacitor (PSC) Motor or ECM High Efficiency Compressors = 15% efficient than the base model (base = 40% Efficiency) $280/ton High Efficiency Case Fans High-Efficiency Case Fans that have High-Efficiency Permanent Split Capacitor (PSC) Motor or $20/fan ECM Floating Head Pressure Control Floating Head Pressure Control $20/ton High Efficiency Display Cases High efficiency Display Cases $40/case Demand Control Defrost Hot Refrigerant defrost w/ hot gas $85/case door Gases Compressor variable Speed Drive (VSD) Retrofit Anti -Sweat Heating Controls Commercial Reach-In Refrigerator VSD Control Variable temperature controls (Humidistat) Energy Star Rated $70/HP $34/case door $70/unit

High-Efficiency Evaporator Fans Walk-Ins Measure Description: Measure provides and incentive for the installation of a high-efficiency evaporator fans in walk-in refrigeration units with permanent split capacitor (PSC) motors or electronically commutated motors (ECM). PSC and ECM motors are motor types that increase overall motor efficiency. Equipment Eligibility: Must be a high-efficiency permanent split capacitor (PSC) motor or electronically commutated motor (ECM) to replace a shaded-pole type motor. High-Efficiency Evaporator Fans Walk-Ins High-Efficiency Permanent Split Capacitor (PSC) Motor or ECM $50/fan motor Detailed Information: A component of refrigeration systems, high-efficiency evaporator fan motors release less heat into the refrigerated room than conventional induction motors (shaded-pole), reducing the energy draw by the fan motor and the compressor. Walk-in fans utilizing more energy efficient PSC motors or ECM reduce the overall energy consumption of the refrigeration system. PSC motors are a common choice for case fan motors with an efficiency rating between 50% and 70% with efficiency increasing with size. ECM are smaller, more expensive, variable speed and more efficient than PSC motors that operate from a single-phase power source with an electronic controller mounted in or on the motor. Walk-ins box refrigeration systems are typically custom built and can be either walk-in cooling or freezer systems. Evaporator fans for walk-ins are typically larger motors than for refrigerated case fans. Compressor-associated refrigeration systems function by removing heat from a desired location, thereby cooling that location. For example, in a walk-in type refrigerator, often, more than 30% of the heat found in the location to be cooled is actually generated by fan motors within the refrigeration system itself. Permanent split capacitor motor is a capacitor motor in which the starting capacitor and the auxiliary winding remain in the circuit for both starting and running. Abbreviated PSC motor. Also known as capacitor start-run motor. An electronically commutated motor (ECM) is a (usually) brushless motor which relies on the external power drive to perform the commutation of stationary copper winding on the stator. This changing stator field causes the permanent magnet rotor to rotate. These can also be referred to as a Brushless DC motor.

High-Efficiency Compressor Measure Description: Measure provides an incentive for the installation of a high-efficiency compressor as part of a commercial or industrial refrigeration system. Equipment Eligibility: = 15% efficient than the base model (base = 40% Efficiency) Note: Efficiency is the ratio of energy into the compressor, to the energy provided by the compressor High-Efficiency Compressor = 15% efficient than the base $280/ton model (base = 40% Efficiency) Detailed Information: A component of refrigeration systems, high efficiency compressors operate up to 20% more efficiently than standard-efficiency compressors. Application ranges include all high, medium, and low temperature evaporating conditions. Typical applications include process chillers, supermarket racks, and environmental chambers.

High-Efficiency Case Fans Measure Description: Measure incentivizes the installation of high-efficiency refrigeration case fans in the form of fans with permanent split capacitor (PSC) motors or electronically commutated motors (ECM). PSC and ECM motors are motor types that increase overall motor efficiency. Equipment Eligibility: Must be a high-efficiency permanent split capacitor (PSC) motor or electronically commutated motor (ECM) to replace a shaded-pole type motor. High-Efficiency Case Fans High-Efficiency Permanent Split $20/fan Capacitor (PSC) Motor or ECM Detailed Information: The case fan is one of the components of the refrigeration system. Case fans utilizing more energy efficient PSC motors or ECM reduce the overall energy consumption of the refrigeration system. Permanent split capacitor (PSC) motor is a capacitor motor in which the starting capacitor and the auxiliary winding remain in the circuit for both starting and running. Abbreviated PSC motor and also known as capacitor start-run motor. They are a common choice for case fan motors with an efficiency rating between 50% and 70% with efficiency increasing with size. An electronically commutated motor (ECM) is a (usually) brushless motor which relies on the external power drive to perform the commutation of stationary copper winding on the stator. This changing stator field causes the permanent magnet rotor to rotate. These can also be referred to as a Brushless DC motor. ECM are smaller, more expensive, variable speed and more efficient than PSC motors that operate from a single-phase power source with an electronic controller mounted in or on the motor.

Floating Head Pressure Control Measure Description: This measure applies to grocery refrigeration systems to improve overall efficiency of an existing system by using an advanced control Method is called floating head pressure control and is measured on a per ton basis. Equipment Eligibility: Must have a minimum SCT (Saturated Condensing Temperature) programmed for the floati ng head pressure control of = 70ºF and include balanced-port expansion valves 1. Floating Head Pressure Control N/A $20/ton Detailed Information: In common practice, compressor discharge (head) is maintained at a constant, high pressure. This guarantees the performance of the equipment, minimizing the risk of inadequate refrigerant flow, adequate pressure differences across pressure valves and freezing protection for the condenser. However, this strategy is not the only way to achieve these results and is far less energy efficient than a float head control strategy. Floating head pressure controls allow the head pressure to float with the ambient wet-bulb (temperature at which relative humidity is at 100%) temperature and therefore the refrigeration system only works as hard as a needs to. The only large change in the performance of the refrigeration system that can be immediately detected is fan operation. In floating head pressure control systems, the fan runs continuously, rather than cycling on and off. Fan energy use increases but this increase is easily offset by the tremendous decrease in compressor energy use. In sum, expected energy saving can be as high as 10%. The use of floating head pressure control would require the use of balanced-port expansion valves which allow satisfactory refrigerant flow over a range of head pressures. 1 The expansion valve is a device used to meter the flow of liquid refrigerant entering the evaporator at a rate that matches the amount of refrigerant being boiled off in the evaporator.

Display Cases Measure Description: Measure incentivizes the installation of high-efficiency display cases. High efficiency display cases incorporate anti-sweat controls, high performance evaporative fans, defrost control, improved insulation, liquid suction heat exchangers, and efficient light systems. Equipment Eligibility: Must replace an existing, open, multi-deck display case with a new, high efficiency, reach-in unit with standard glass doors with an Electronical ly Commutated Fan Motor (ECM), T-8 lamps and an electronic ballast or LED lighting. This is for remote cases only. Deli cases, custom coolers/freezers and walk-in boxes with reach-in doors do not qualify. Display Cases High efficiency $40/case Detailed Information: Refrigerated display cases achieve higher performance efficiency and reduce overall energy consumption by incorporating anti -sweat controls, high performance evaporative fans, defrost control, improved insulation, liquid suction heat exchangers and efficient light systems. With energy usage intensity of 43 kwh to 70 kwh per square foot per year, supermarkets are one of the most energy-intensive commercial building types in the United States. A major factor affecting the design and operation of supermarket refrigeration systems is the cooling load requirements of the display cases. Medium-temperature displays cases and, in particular, open vertical display cases, are one of the most thermally vulnerable display cases in supermarkets. These display cases, which are typically used to merchandize meat, dairy and delicatessen, fish and produce, operate at discharge air temperatures of 28 o F to 32 o F. They also comprise the largest portion of display case line ups.

Demand Control Defrost Hot Gas Measure Description: This measure pertains to the installation of a refrigerant defrost device for an evaporator, used to remove frost from the coils with hot gas and thereby increase energy efficiency. Equipment Eligibility: Refrigerant defrost w/ hot gas Demand control defrost hot gas Refrigerant defrost w/ hot gas $85/case door Detailed Information: When frost collects on the evaporator, it reduces coil capacity by acting as a layer of insulation and reducing the airflow between the fins. In hot gas defrost, refrigerant vapor from either the compressor discharge or the high pressure receiver is used to warm the evaporator coil and melt the frost that has collected there.

Compressor Variable Speed Drive (VSD) Retrofit Measure Description: Measure pertains to Variable Speed Drive (VSD) retrofit installations on commercial and industrial refrigeration compressors of any horsepower. A variable speed drive system is more efficient than a single-speed drive, allowing for compressors to run at the optimal speed depending on demand. Equipment Eligibility: VSD control for refrigeration systems. Compressor VSD Retrofit VSD Control $70/HP Detailed Information: Variable Speed Drives (VSD) are an economical and efficient retrofit option for existing compressor installations. VSDs are electrical devices that vary the speed of the motor in the compressor by changing the frequency of the motor s electrical power between zero and 60 Hertz (Hertz unit of frequency equal to one cycle per second). VSDs allow the motor to run at lower speeds under part-load conditions, thereby yielding higher levels of overall energy efficiency.

Anti-Sweat Heating Controls Measure Description: Typically used in grocery stores enables the user to turn refrigeration display case anti-sweat heaters off when ambient relative humidity (humidity level of the air around the case) is low enough that sweating will not occur. Without the control, the heaters generally run continuously. Equipment Eligibility: Variable temperature controls (Humidistat). Humidistat is a device used to measure humidity. Anti -Sweat Heater Controls Variable temperature controls $34/case door (Humidistat) Detailed Information: Customers will receive $34 for each case door installed with a variable temperature control (Humidistat). The device enable users to turn off anti-sweat heaters when ambient humidity is low, reducing overall power consumption. The anti -sweat heaters are used to stop condensation developing on the display cases. Variable temperature control will turn off these heaters when there is not enough moisture in the air to condensate.

Commercial Reach-In Refrigerator Measure Description: Reach-in refrigerators are typically found in restaurants, cafeterias, hospitals, schools and convenience stores. They are medium- (40 F) or low-temperature (0 F), portable devices and range in size from 20 to 90 cubic feet. Equipment Eligibility: Must be Energy Star rated. Commercial Reach-In Refrigerator Energy Star $70/unit Detailed Information: ENERGY STAR labeled commercial refrigerators and freezers are more energy efficient because they are designed with components such as ECM evaporator and condenser fan motors, hot gas anti-sweat heaters, or high-efficiency compressors.