CRITICAL ENVIRONMENTS. Fully Integrated Systems for: Operating Rooms, Isolation Rooms & Pharmacies

Similar documents
PRICE RESEARCH CENTER NORTH. The Most Extensive and Technologically Advanced Research and Development Air Distribution Test Lab in the HVAC Industry.

Active & Passive Beams

Displacement Ventilation

Mediclean Complanate Ultra Clean Ventilation

Clean Air Laminar Flow Ceiling CG 3 A CLEAN AIR WORLD. Draft-free, comfortable room climate. Minimal, undisruptive noise level

Krantz. HVAC systems for hospitals. System solutions

ACBH/ACBV ACTIVE CHILLED BEAM INSTALLATION MANUAL. Date: 05/12 Reference # : L-50.

Operating Room Diffuser System with Integrated LED Lighting

Space Air Diffusion II

PRODUCTS TAO TAO PRODUCT: ADVANCING THE SCIENCE OF AIR DISTRIBUTION. temperature ambient optimizer. Redefine your comfort zone.

Theatre Classification and Air Particle Count Is that Surveillance?

DESCRIPTION OF TECHNOLOGY

Ventilation for Healthcare Facilities

SYSTEM SOLUTIONS SCHOOLS

Ventilation for Healthcare Facilities. Topics to be Covered

SYSTEM SOLUTIONS SCHOOLS

photo by PFC Price Fan Column

ULTRAVIOLET INDIRECT AIR DISINFECTION

Engineering Guide VAV Diffusers. Please refer to the Price Engineer s HVAC Handbook for more information on VAV Diffusers.

How to comply with CDC Guidelines

A REASONABLE ALTERNATIVE TO CHILLED BEAMS Dan Int-Hout Chief Engineer

BARRIER TECHNOLOGY RABS & ISOLATORS FOR ASEPTIC PROCESSING

UVC GERMICIDAL TECHNOLOGY APPLICATIONS IN HOSPITALS

Iso Solutions. Enabling wellbeing

General Purpose Laminar Flow Cabinets, Horizontal and Vertical. Horizontal Flow Vertical Flow

IDL20e (2 way discharge) IDS60e (4 way discharge) Inffusers. UDI (vertical discharge) Frequently Asked Questions

A Building Area: 10,567 SF 20,321 SF total building

Ultraflex Ceiling Grid (UFR)

Clean Bench Animal Transfer Stations

CHINOOK WARM AIR GAS FURNACE DESIGNED, ENGINEERED AND MANUFACTURED IN CANADA INCLUDING COMPONENTS MADE IN THE USA

MECHANICAL VENTILATION

Integrated Solution PARTNERS

DIF-OT Ceiling Filter. The optimized laminar airflow

Stainless Steel Healthcare Equipment

Autoclaves and Accessories for Healthcare Professionals

Fan System for Drop Ceilings

maximize displacement ventilation Opportunities

Innovation in air purification unmatched air quality

UFAD and Displacement Ventilation. Dan Int-Hout, FASHRAE Chief Engineer Krueger Richardson, Texas

PFS Single stage axial fan The axial fan for modern boiler plants

CLEAR ROOM EQUIPMENT CLEAR ROOM EQUIPMENT AIR SHOWER PRESSURE RELIEF DAMPER PASS BOX PASS THOUGH CLEAN BENCH VERTICAL CLEAN BENCH HORIZONTAL

Technical Concept. Plenum Integrated Filter Fan PIFF 3-AC PIFF 3-EC

New LED Product Offerings

Technical Concept. Ultraflex Ceiling Grid (UFR) All Types Cleanroom Ceiling Systems

Better Air Dispersion for. Underfloor. Plenums

SECTION AIR OUTLETS AND INLETS

Ultraclean ventilation. The shape of canopies to come.

Air Handling Units. Ranging from 15 to 2,000+ tons and 500 to 400,000+ CFM

CHINOOK WARM AIR GAS FURNACE DESIGNED, ENGINEERED AND MANUFACTURED IN CANADA INCLUDING COMPONENTS MADE IN THE USA

Modu-Kleen. Downdraft Dust Collector SERIES

Square Ceiling Diffusers : All extruded aluminum constructions. Opposed blade damper is adjustable from face of diffuser. Available in square and

Biological Safety Cabinets. Biological Safety Cabinets

EMI ENGINEERING SUBMITTAL

DESIGN OF AIR-CONDITIONING SYSTEM FOR SARS WARDS. By Yuguo Li and SARS Busters * Background

General Purpose Laminar Flow Cabinets, Horizontal and Vertical

Precision Containment for All Applications

Ohio Medical is the only name you need to know for your medical suction and oxygen therapy and medgas equipment needs.

Guidelines for Ideal Layout for an Operating Theater Complex. Dr.R.D.Ravindran Aravind Eye Hospital Madurai

Raised Access Floor - (AE Breadth Area)

Safe Operating Procedure (Revised 2/10)

VWR symphony CO 2 INCUBATORS

OPERATION AND MAINTENANCE MANUAL

Advanced Air. Hard Wired Damper Control Panels. Systems 10, 11, & 12. Hard-Wired Systems. Bespoke Systems Available. Value Engineered Solutions

Automatic Cyanoacrylate Fuming Chamber 24 33T 60T 72XL. Safely Detect Quality Latent Prints and Reproducible Results

Rotary Screw Compressors BSD Series With the world-renowned SIGMA PROFILE Air deliveries 3.6 to 8.15 m 3 /min, Pressure 5.

ICU/CCU Door Besam VersaMax

KLIMA Active Chilled Beams

Wideline presents The Paragon Range

Fume Hood Safety TYPES OF FUME HOODS

Rittling Induction Units Catalog

S ILENT Series INSTALL SILENCE, INSTALL QUALITY OF LIFE. The Quietest Extractors in the World in their Category 26,5

Faster UltraSafe Class II Microbiological Safety Cabinets. Protection, safety, reliability. And more.

Howorth Air Technology. Pharmaceutical Containment Solutions

Jim Aswegan Chief Engineer

THERMA FUSER SIDEWALL LINEAR VAV DIFFUSER

Gelaire BH-EN and UltraSafe cabinets

Linear Floor Heaters

Basic Hood Considerations The design process for a successful kitchen ventilation system starts when the engineering design HVAC team receives

Animal Tissue Culture SQG 3242 Equipment and Lab design. Dr. SITI PAULIENA MOHD BOHARI

Cleveland Clinic Design Standards MECHANICAL SYSTEMS DESIGN GUIDELINES HVAC AIR DISTRIBUTION PART I - GENERAL 1.1 SUMMARY

MCB SERIES. cross ventilation cartridge dust collector

Performance Aire offers three VAV comfort solution packages.

ICU/CCU Door ASSA ABLOY VersaMax 2.0

EMI ENGINEERING SUBMITTAL

Isolation room exhaust fan noise in a hospital

OIL FREE WATER INJECTED SCREW COMPRESSOR WIS 40-75

INTEGRATED LOUVERS in Doors and Openings FOR VISION AND DAYLIGHT CONTROL

BSC CLASS II, TYPE A2 BIOLOGICAL SAFETY CABINET SERIES. Optimum protection of personnel, product and environment. BSC Class

Architectural Engineering Senior Thesis Mechanical System Redesign

UVC in the Operating Room.

METALWORKS. Airtite Panels. Radiant Ceiling Systems

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

PDH & Professional Training

CHEMICAL FUME HOOD PROGRAM

DRYAIR Turnkey Dry Room Standards

G6RC Series TECHNICAL SPECIFICATIONS

Questions??????? Thank you

Create Clean Air. The specialists in Indoor Air Quality

Cleanroom systems. Supply air ceiling and recirculated air ceiling OP. for operating rooms with low-turbulence displacement flow

LABORATORY CABINETS 103

Transcription:

CRITICAL ENVIRONMENTS healthcaresolutions Fully Integrated Systems for: Operating Rooms, Isolation Rooms & Pharmacies Research Facilities, Process Labs & Pharmaceutical www.price-hvac.com/critical

healthcaresolutions CRITICAL ENVIRONMENTS When Safety is Critical, choose Price. Price is the only manufacturer that has the products and systems for an entire healthcare facility: The largest selection of Critical Environment products in the industry Extensive Application Engineering support for product selection & application guidance Complete systems and solutions with proven performance Fully tested, customized products to meet your specialized requirements Price has decades of experience supplying product and system solutions for healthcare facilities: Hospitals, Burn Centers, Isolation Rooms Patient Rooms Support Facilities Laboratories & Pharmacies Operating Rooms 4 OFFICES Life saving surgeries can be performed in optimal conditions with Acufl ow O.R. Systems, minimizing the risk of airborne infection and maximizing comfort. AIR CURTAIN SUPPLIES/LOCKERS OR OR OR OR ER XRAY ER WAITING AREA LAMINAR FLOW ISOLATION ICU 2

Price Displacement Ventilation Systems (Purafl o ) are designed to create positive impact on indoor air quality and comfort in the patient room. Laboratories and pharmacies are critical, cleanroom environments with sensitive processes that require specialized air distribution strategies. Patient General 6 8 Labs and Pharmacies Critical care patient rooms are carefully controlled environments that protect and Price has the specialized comfort both the patients and products that help protect the staff that care for them the patient and/or staff during in airborne the healing infectious process. isolation rooms and protective isolation rooms. Patient Critical 7 Support areas, such as MRI and examination rooms, present a unique challenge for air distribution systems. Price has products designed to suit these complex areas of your healthcare facility. MRI Examination Rooms 10 Support Areas EXAM ROOMS INTERNAL PHARMACY LAB PUBLIC PHARMACY LOBBY EXAM ROOMS CLINIC 10 Common Areas OFFICES ATRIUM WAITING AREA RECEPTION WAITING AREA OFFICES Price also specializes in products and application support for all common areas in healthcare facilites. These include: Offi ces Hallways Waiting Areas Lobbies Entrances PATIENT WARD MRI www.price-hvac.com

healthcaresolutions CRITICAL ENVIRONMENTS Acuflow O.R. Systems Acuflow O.R. Systems from Price represent an integrated approach that meet the specialized needs of an operating room. Detailed design information on these specialized systems can be found in Volume II: Products for Critical Environments of the Price Catalog. The Acuflow O.R. Systems approach provides design professionals: Selection and layout of Price O.R. air distribution components Detailed supporting submittal packages Compliance with the latest standards and project design requirements Laminar Flow System The Price Laminar Acufl ow O.R. System is designed to control air contamination in the operating room by providing low mixing uniform vertical air supply from Laminar Flow Diffusers. Price has the industry's largest selection of Laminar Diffusers and offers optional integral HE, HEPA or ULPA fi ltration for superior performance. Supply Air Return Air LFD SERIES Laminar Flow Diffusers UNITEE CR/HDCR Cleanroom Ceiling Systems 700H SERIES Stainless Steel Return Grilles 4

Supply Air Exhaust Air Air Curtain System Laminar Diffusers over the surgical site are surrounded by Price Hospital Operating Room Diffusers (HORD) to provide a clean surgical zone enclosed in a perimeter air curtain. The air curtain maximizes fl exibility by increasing ceiling space for mounting medical equipment, and providing additional cooling capacity to meet the heat loads of the modern O.R. 700H SERIES Stainless Steel Return Grilles LFD SERIES Laminar Flow Diffusers UNITEE CR / HDCR Cleanroom Ceiling Systems HORD Linear Slot Diffusers (Air Curtain) Price Products for Operating Rooms LFD / LFD2 / LFDSS / LFDC Laminar Flow Diffuser HORD / HORDSS / HORDM / HORDSSM Perimeter Slot Diffuser 700H SERIES Stainless Steel Return Grille UNITEE CR Modular Cleanroom Ceiling UNITEE HDCR Heavy Duty Welded Cleanroom Ceiling SPV / SEV / SDV Single Duct Variable Volume Terminal Unit SPVQ / SEVQ / SDVQ Quiet Single Duct Terminal Unit Engineered to provide a uniform vertical projection of supply air at controlled low mixing and velocity Linear Slot Diffusers with an integral plenum that forms a perimeter clean air curtain around the operating table Designed for cleanrooms, laboratories and hospital applications Modular extruded aluminum ceiling grids with integral gasket specifically designed for cleanroom applications Heavy-duty welded extruded aluminum ceiling grids with a continuous gasket specifically designed for cleanroom applications Designed to control the airflow rate of conditioned air into an occupied space An integrated terminal unit and silencer in a carefully engineered, fully tested and certified assembly www.price-hvac.com 5

healthcaresolutions CRITICAL ENVIRONMENTS Price Patient Rooms Puraflo Displacement Diffusers by Price harness natural convection currents to create a safer, more refreshing environment in standard patient rooms. Improved indoor air quality Reduced risk of airborne infection Part of a sustainable building strategy Helps to protect patients and staff Increased comfort Price Patient Room Solutions Price has partnered with leading healthcare providers and engineering fi rms in testing and developing Displacement solutions for healthcare facilities. SPV / SEV / SDV Single Duct Variable Volume Terminal Unit VENTURI VALVE PRICE PATIENT ROOMS Displacement Diffuser SDE Quiet Exhaust Single Duct Terminals VENTURI VALVE RPL / RPM Radiant Panels Patient Rooms Displacement Ventilation can provide signifi cantly higher levels of indoor air quality in patient rooms. Displacement carries pollutants away from the occupied zone, minimizing the risk of the patient and staff being exposed to contaminants. The Puraflo Diffuser for patient rooms features a removable face and stainless steel option 6

Price Products for Critical Care Patient Rooms Protection for Patients Protective Isolation Diffusers located above the bed provide comfort while bathing the patient in clean, breathable air, before cleansing visitors and leaving the room through a high return located at the entrance. Airborne Infectious Isolation Patients are bathed in a continual stream of clean air, while carefully extracting the air that the patient has come into contact with to reduce the risk of airborne infection. Protection for Staff & Visitors Price Products for Patient Rooms PURAFLO DF1W / DF1WSS 1-Way In-Wall Displacement Diffuser SPD / SPD-HI / AMD-EX Overhead Diffuser RPL / RPM Radiant Panels SPV / SEV / SDV Single Duct Variable Volume Terminal Unit VV Venturi Valve Designed to bring the high performance of the DF1 to in-wall applications, the removable face allows for easy maintenance and installation Designed to provide a large volume of air to spaces that need to satisfy both architectural appeal and air distribution performance criteria Designed to provide zone radiant heating and cooling Designed to control the airflow rate of conditioned air into an occupied space in response to a control signal, usually a thermostat Variable volume supply and exhaust valves designed for control of critical spaces Price Products for Critical Care Patient Rooms LFD / LFD2 / LFDSS / LFDC Laminar Flow Diffuser RAVD Radial Adjustable Vane Diffuser FRFD Flush Face Radial Flow Diffuser Engineered to provide a uniform vertical projection of supply air at controlled low mixing and velocity Designed to provide a fully adjustable air pattern for flexible installations Designed to supply large air volumes in confined critical spaces that require low room air velocity www.price-hvac.com 7

healthcaresolutions CRITICAL ENVIRONMENTS Laboratories Price Critical Environment products maintain the desired cleanliness level in laboratories without disrupting the sensitive process with unwanted drafts. VENTURI VALVE With SP300 Sensor RFD / FRFD / RAVD Radial Flow DIffuser SPV / SEV / SDV Single Duct Variable Volume Terminal Unit UNITEE CR / HDCR Cleanroom Ceiling Systems RPV / REV / RDV Exhaust Control Valve HDCR-Plenum System Price Products for Laboratories The HDCR Plenum System integrates multiple Laminar Diffusers into a single pressurized heavy duty plenum unit, reducing air duct connections and installation labor. Complete integrated package Reduced inlet connections Labor savings RFD / FRFD / RAVD Radial Flow DIffuser UNITEE CR / HDCR Cleanroom Ceiling Systems SPV / SEV / SDV Single Duct Variable Volume Terminal Unit RPV / REV / RDV / RPVSS Exhaust Control Valve Designed to supply large air volumes in confined spaces with minimal velocity Extruded aluminum ceiling grids specifically designed for cleanroom applications Designed to control the airflow rate of conditioned air into an occupied space in response to a control signal, usually a thermostat Control valves for corrosive and noncorrosive applications 8

Pharmacies Hospital pharmacies are governed by increasingly strict regulations. Using Price products helps you to ensure that your fi nished pharmacy has a high performing air distribution system that meets these requirements. The Price offering includes: Air outlets and HEPA fi ltered laminar supply diffusers for ISO Class 7 Clean Spaces Fan fi lter units with integral fans for areas being renovated or with pressure drop issues High effi ciency ECM motors to maintain constant airfl ow across fi lters Unitee CR/HDCR Ceiling Systems for easy ceiling access and future fl exibility LFD / LFDSS / LFD2 SERIES Laminar Flow Diffusers 700H SERIES Stainless Steel Return Grilles Price Products for Pharmacies LFD / LFD2 / LFDSS / LFDC Laminar Flow Diffuser UNITEE CR / HDCR Cleanroom Ceiling Systems FFU / FFUSS / FFUD Fan Filter Unit Engineered to provide a uniform vertical projection of supply air at controlled low mixing and velocity Extruded aluminum ceiling grids specifically designed for cleanroom applications Designed to provide unidirectional vertical airflow of filtered, clean air over a cleanroom space 700H SERIES Stainless Steel Return Grille Designed for cleanrooms, laboratories and hospital applications www.price-hvac.com 9

healthcaresolutions CRITICAL ENVIRONMENTS Support & Common Areas Price is the only manufacturer of air distribution products for healthcare that specializes in solutions for the entire healthcare facility, helping to ensure high performance and improved indoor air quality throughout the building. EXAM ROOMS LOBBY CLINIC OFFICES WAITING AREA RECEPTION WAITING AREA MRI MRI MRI Rooms can pose a challenge for ventilation systems. Price offers a full line of non ferrous products suitable for use in MRI rooms. Hallways High induction outlets such as the Price Square Plaque Diffuser (SPD) or directional louvered air outlets (SMD) are ideal for corridors and hallways. The air supplied to the space maximizes comfort while keeping sound levels low. EXAM ROOMS OFFICES ATRIUM PATIENT WARD Waiting Areas, Lobbies & Atria The conventional method of ventilating waiting rooms is with an overhead system, which is well proven and effective. A displacement system may reduce the exposure of airborne contaminants to occupants waiting to see their healthcare provider. Lighter than air contaminants are displaced upwards out of the occupied zone and exhausted from the room. ER WAITING AREA ER XRAY Offices Conventional overhead supply systems are always a good choice for offi ces; however, Displacement Ventilation is another option on that features high indoor air quality, high levels els of comfort and low noise levels. Examination Rooms ICU Price SCD Square Cone Diffusers are common in examination rooms and provide a comfortable, draft free, quiet environment. Displacement outlets are also viable, displacing heat and contaminants up and away from the doctors and patients to high level returns. Displacement Ventilation reduces the chance of infectious particles being passed from one room occupant to the next. OFFICES SUPPLIES/LOCKERS EXAM ROOMS Other Products & Solutions Price has the ventilation solution for all areas of your hospital. Price can provide a complete package with our full line of Terminal Units and Controls to compliment Price air outlets. If you have a special room, Price has the products and resources to help you. 10

Ceiling Systems Price Unitee CR / HDCR Ceiling Systems are designed to provide access to the ceiling space as well as support the installation of diffusers, infi ll panels and lighting fi xtures. The gasketed construction prevents air leakage between the ceiling plenum and occupied space below. Universal assembly clips allow quick, tool free removal of sections for access to equipment in the space above Unitee CR Ceiling System Unitee CR Ceiling Systems are supplied as separate components for fi eld assembly, allowing full access to plenum mounted equipment after installation. A sterile white powder coat fi nish selected for its durability and chemical resistance High quality extruded aluminum members Vinyl gaskets seal between the Unitee CR and clip-in panels High quality, heavy duty extruded aluminum T-bars Large factory welded modules for fi eld assembly Unitee HDCR Ceiling System Unitee HDCR Ceiling Systems are supplied in large, factory welded modules and provide a strong ceiling support structure for easy fi eld installation. A sterile white powder coat fi nish selected for its durability and chemical resistance Continuous gasket to reduce risk of leaks www.price-hvac.com ww. p r i 11

2975 Shawnee Ridge Court Suwanee, Georgia USA 30024 Ph: 770.623.8050 Fax: 770.623.6404 999 North Thornton Road Casa Grande, Arizona USA 85222-3809 1290 Barrow Industrial Boulevard Auburn, Georgia USA 30011 638 Raleigh Street Winnipeg, Manitoba Canada R2K 3Z9 Ph: 204.669.4220 Fax: 204.663.2715 The founding principles of our company have never changed - business integrity, first class service and a commitment to people. Price manufacturing endeavors arose from our belief that we could supply superior products and services at a reasonable price. Our mission is to become the worldwide supplier of preference for air distribution products and services. You can rely on Price our products and services with confidence. Your Local Price Representative: Product Improvement is a continuing endeavor at Price. Therefore, specifications are subject to change without notice. Consult your Price Sales Representative for current specifications or more detailed information. Grilles & Diffusers Critical Environments Terminals Sustainable Building Noise Control www.price-hvac.com Price is a registered trademark of E.H. Price Limited. 2009. Printed in Canada 2009 2009/04/01-226 - v002