GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

Similar documents
WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E

WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

AFUE 95% Heating Input 50,000 to 200,000 Btuh

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ. Steady-State Efficiency - up to 81% Input - 30,000 to 75,000 Btuh

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

GAS FURNACES G20RE/ G20RXE EXISTING NEG ENGINEERING DATA EXISTING NEG. Typical Applications

MERIT SERIES Downflow

ELITE SERIES Downflow - High Efficiency Blower Motor

13 GEP A L P - 1 A

Product Data. ama. BW1, BW2 & BW3 Gas-Fired Water Boilers Series B

8+* Bulletin No November 1997

RGE 13 A T - 1 A

SL280DFV. DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower

ELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b

LF24. UNIT HEATERS Horizontal - 60 HZ. Thermal Efficiency - up to 80.5% Input - 100,000 to 390,000 Btuh LF A MODEL NUMBER IDENTIFICATION

Peerless Boilers. Series MI. Residential Gas Boilers

Replacement parts EG/PEG

G34M Bulletin #69/ August 2003

JE Series Cast Iron Commercial Natural Gas Steam Boiler Submittal/Specifications

High efficiency, cast-iron gas boiler

Product Data BW9 WATER BOILER SERIES B

INSTALLATION INSTRUCTIONS PLYMOUTH XTREME GAS-FIRED HOT WATER BOILERS

G61MP. ELITE Series Multi-Position - Two-Stage Heat. AFUE - Up to 95% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2.

FSB Series Gas-Fired Hot Water

OHR23. ELITE SERIES Horizontal/Downflow. AFUE - Up to 83.5% Input - 105,000 to 154,000 Btuh Nominal Add-on Cooling - 2 to 5 Tons O HR 23 Q 3/4-105/120

MERIT SERIES Downflow

DuralokPlus Aluminized Steel Heat Exchanger G 32 V

SENTRY. High efficiency, cast-iron gas boiler LOWER PROFILE MAKES PROBLEM INSTALLATIONS EASY

G61MP. ELITE SERIES Multi Position Two Stage Heat G A S F U R N A C E S. AFUE 94.1% Input 44,000 to 132,000 Btuh Nominal Add on Cooling 2.

DAVE LENNOX SIGNATURE COLLECTION Lo-Boy - Variable Speed Blower

Suggested Specifications Prestige Excellence 110

PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

DIVISION FINNED WATER-TUBE BOILERS

Product Data. ama. Model BW9 Gas-Fired Condensing Water Boiler Series A FEATURES

VICTORY VSPH VICTORYVSPH THE PERFECT CHOICE FOR. Cast-iron sealed combustion, direct vent gas boiler

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS

SERIES 24. Series 24 Features. Commercial, Forced Draft, Hot Water or Steam Boiler. The right fit for any commercial job

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

Raypak Residential Products

DIVISION FINNED WATER-TUBE BOILERS

DIVISION FINNED WATER-TUBE WATER HEATERS

U n i t H e at e r s

DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower

GSR21Q GAS FURNACES EXISTING NEG EXISTING NEG ENGINEERING DATA HORIZONTAL POSITION. Typical Applications DOWN-FLO POSITION

SLP98UHV WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

VICTORYII. Cast-iron, power vent gas boiler BOILER FOR OLDER HOMES.

Boiler & Water Heater

Bryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired

83.5 % UP TO 95 % 86.5 % High to Mid-Efficiency Residential & Commercial Heating Solutions. Boilers and Indirect Water Heaters

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

VICTORYVSPH THE PERFECT CHOICE FOR NEW RESIDENTIAL CONSTRUCTION RELIABILITY AND ECONOMY.

DIVISION FINNED WATER-TUBE WATER HEATERS

MERIT Series R-410A - Upflow / Horizontal

SECTION HEATING BOILERS

FINNED WATER-TUBE POOL HEATERS

MERIT Series R-410A - Upflow / Horizontal

MERIT SERIES Downflow

LGB Gas fired boiler

GSR21Q PULSE21 SERIES

Copper Finned Gas-Fired Volume Water Heaters, Boilers and Commercial Pool Heaters. Low NOx, Quiet, Efficient, Space-Saving

Series 8H. Cast Iron Gas Fired Commercial Water Boiler

Installation, Start-up, and Operating Instructions

V8MS Mode Selection Box for VRA Heat Recovery - 60HZ

MERIT SERIES Up Flow / Horizontal

RG7D 1-Stage Heat Series

DIVISION FINNED WATER-TUBE BOILERS

CSD-1 COMMERCIAL BOILER CONTROLS

LRP14GE. SEER AFUE - 81% 2 to 5 Tons Cooling Capacity - 22,600 to 57,000 Btuh Input Gas Heating Capacity - 54,000 to 126,000 Btuh

Gas Valve. Combustion Air Intake. Supply Air Blower AM30. Typical Applications

A-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents

PWXL Cast Iron Gas Fired Hot Water Boilers INSTALLATION, OPERATION & MAINTENANCE MANUAL

A. Section Common Motor Requirements for HVAC Equipment: Fan motors.

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

LRP14DF. Dual-Fuel Residential - R-410A L RP 14 DF X P A MODEL NUMBER IDENTIFICATION

GAS FIRED ATMOSPHERIC ELECTRONIC VERSION kw

FINNED WATER-TUBE POOL HEATERS

GB Condensing Gas Boiler

INSTALLATION INSTRUCTIONS

LGB COMMERCIAL GAS BOILER. Versatile combustion control systems. Made with Weil-McLain quality COMMERCIAL GAS BOILER APPLICATIONS INCLUDE:

Bosch Buderus SSB255/399/512 Stainless Steel Condensing Boiler

Weil-McLain part numbers are found in Weil-McLain Boilers and Controls Repair Parts Lists.

Product Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input

User s Information Manual

G315/6 Cast Iron Boiler

Installation, Start-Up, and Operating Instructions

MERIT SERIES Upflow / Horizontal

CINCINNATI, OH USA

installation, operation and maintenance MANUAL

Description Model Weil-McLain part number. Vent Termination Kit for 3" Stainless Steel All

PLYMOUTH STEAM SERIES 2 GAS-FIRED STEAM BOILERS

FOR FORCED HOT WATER MODEL NUMBERS: 15045, 15070, 15096, 15120, 15145, 15175, 15195, 15245, 15295

Utica Boilers MAC Submittal

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

G315/5 Cast Iron Boiler

WPSB SERIES II GAS-FIRED HOT WATER BOILERS

Transcription:

P R O D U C T S P E C I F I C AT I O N S W A T E R H E A T E R S / B O I L E R S CONSERVATOR Gas-Fired Steam Boiler Bulletin No. 20263 October 200 Supersedes September 2008 AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh MODEL NUMBER IDENTIFICATION GSB 8-075 S Series GSB = Gas-Fired Steam Boiler AFUE 8 = 80% Ignition E = Electronic Ignition S = Standing Pilot Ignition Capacity (Input) 075 =75,000 Btuh 2 =2,000 Btuh 50 = 50,000 Btuh 87 = 87,000 Btuh 225 = 225,000 Btuh 262 = 262,000 Btuh 299 = 299,000 Btuh FEATURES CONTENTS Dimensions...5 Features... High Altitude Derate...4 Installation Clearances...5 Model Number Identification... Optional Accessories...4 Specifications...4 NOTE - BOILERS ARE NOT AVAILABLE IN CANADA! WARRANTY Cast iron boiler assembly - Limited twelve year warranty in residential applications only. All other covered components - Limited one year warranty in residential applications. Refer to Lennox Equipment Limited Warranty certificate included with equipment for details.

FEATURES APPROVALS Low pressure, sectional cast iron boilers design certified by CSA for use with natural gas or LPG/Propane. Annual Fuel Utilization Efficiencies are based on US DOE test procedures and FTC labeling regulations. I=B=R ratings are certified in accordance with standards set by The Hydronics Institute. Boiler heat exchanger assemblies are constructed and hydrostatically tested in accordance with American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code Section IV Standards for cast iron heating boilers. APPLICATIONS Gas fired steam boilers are available in seven sizes with heating inputs of 75,000 to 299,000 Btuh. AFUE s of up to 82.7%. Available with a choice of electronic or standing pilot ignition systems. Natural gas or LPG/Propane (LPG with optional conversion kit). Boilers may be used in a wide variety of applications including standing cast iron radiators, steam air handlers and convectors. May also be used in conjunction with chilled water systems. Compact size allows easy installation in a basement or utility room. All units are completely factory assembled with all controls installed and wired. Each unit is factory test operated to insure dependable performance. HEATING SYSTEM Cast Iron Boiler Assembly Boiler sections and push nipples are constructed of long life cast iron. Boiler sections and push nipples expand and contract together, providing positive watertight seal. Boiler components are easily accessible for cleaning and servicing. Electronic Ignition ( E Models Only) Solid-state electronic spark igniter provides positive ignition of pilot burner on each operating cycle. Pilot gas is ignited and burns during each running cycle (intermittent pilot) of the boiler. Main burners and pilot gas are extinguished during the off cycle. Ignition system permits main gas valve to open only when the pilot burner is proven to be lit. Pilot operation is fully automatic on demand for heat. Should a loss of flame occur, the main valve closes, shutting down the unit. Standing Pilot Ignition ( S Models Only) Manual lighted standing pilot provides dependable and safe burner ignition. Automatic Gas Control Silent operating gas controls provide 00% safety shut off. 24 volt redundant combination gas control valve combines automatic safety pilot, manual shut off option (On-Off), pilot filtration, automatic electric valve (dual) and gas pressure regulation into a compact combination control. Dual valve design provides double assurance of 00% close off of gas to the pilot and main burners on each off cycle. Titanium Burners Titanium composite burners resist corrosion and oxidation. Superior strength and longevity. Used with natural or LPG/Propane gas. Relief Valve Furnished as standard for field installation in top of cabinet. Valve provides for pressure relief of heating system in case of abnormal operating conditions. Valve opens at 5 psig and is approved by ASME. Steam Pressure Gauge Located in top of unit cabinet. Gauge monitors system for safe and reliable operation. Water Level Gauge Furnished on side of unit. Allows a visual inspection for correct cold water level in the boiler. Correct level is stamped on cabinet side behind glass tube. Brass Drain Valve 3/4 in. brass drain valve is furnished for field installation in return piping. OPTIONS LPG/Propane Conversion Kit Conversion kit required for field changeover from natural gas. See Specifications tables. / Page 2

FEATURES VENTING Blocked Vent Shutoff Sensor Temperature sensitive fusible-link device prevents unit operation in case of flue blockage. Sensor is furnished as standard and factory installed at the relief opening of the draft diverter. Vent Damper Motorized vent damper electrically interlocks with the gas ignition system to increase efficiency of heating system by reducing loss of heated air up the chimney after burner shut off. Also reduces chimney infiltration during boiler off cycle. Furnished as standard for field installation. CONTROLS Flame Rollout Switch Temperature sensitive fusible-link device is furnished and factory installed on the boiler base just outside of the burner box. Fuse prevents unit operation in the event combustion products passageway through the flueway is reduced or blocked. Steam Pressure Limit Control Factory installed control gives protection against abnormal operating conditions. Adjustable control automatically shuts off gas to the burners if steam pressure reaches cut-off setpoint. Factory installed on side of unit cabinet. Low Water Cut-Off Electronic probe type control automatically shuts off gas to the burners if water level drops below minimum safe levels. Factory installed in boiler. CABINET Constructed of heavy gauge steel with a baked-on enamel paint finish. Cabinet is fully insulated with fiberglass insulation, keeping cabinet surface temperatures low. Controls are shipped factory installed on right side of cabinet and may be field relocated to left side of cabinet. Supply and return steam lines are furnished on both sides of cabinet. Plugs are furnished for unused side. Burner access panel is easily removed for servicing. Integral draft diverter is part of unit cabinet. Transformer/Wiring Junction Box 24 volt control transformer and wiring junction box is furnished on side of unit cabinet for field wiring connections. OPTIONS Combustible Flooring Base For applications where it is necessary to locate boiler on a combustible floor, a combustible floor base must be ordered extra for field installation. See Specifications tables for order no. OPTIONS Thermostat See Thermostat bulletins in Controls section and Lennox Price Book for a complete list of thermostats. / Page 3

SPECIFICATIONS Model No. Electronic Ignition -075E Gas Heating Performance Heating capacity Btuh Net I=B=R rating Btuh Net I=B=R rating sq. ft. radiation Standing Pilot -075S -2E -2S -50E -50S -87E -87S -225E -225S -262E -262S -299E -299S Input Natural gas 75,000 2,500 50,000 87,000 225,000 262,500 299,000 LPG/Propane 70,000 05,000 40,000 75,000 20,000 245,000 280,000 Output Natural gas 62,000 9,000 22,000 53,000 83,000 24,000 245,000 LPG/Propane 58,000 85,000 4,000 43,000 7,000 200,000 229,000 Natural gas 42,000 68,000 92,000 5,000 37,000 6,000 84,000 LPG/Propane 44,000 64,000 86,000 07,000 28,000 50,000 72,000 Natural gas 96 283 383 479 57 67 767 LPG/Propane 83 267 358 446 553 625 77 2 AFUE - E electronic ignition models 82.7% 80.4% 80.6% 80.9% 8.% 8.3% 8.5% 2 AFUE - S standing pilot models 8.% 78.8% 79.2% 79.6% 80.% 80.5% 80.9% Boiler Data Number of boiler sections 3 4 5 6 7 8 9 Connections in. Boiler capacity - U.S. gallons Electrical characteristics Net boiler heating area - sq. ft. 8.38.7 4.73 8.29 2.85 25.4 28.97 Full 4.2 5.90 7.60 9.30.00 2.70 4.40 Water level 2.6 3.80 5.00 6.20 7.40 8.60 9.80 Flue size diameter (round) 5 6 6 7 7 7 7 Gas piping Natural gas /2 /2 /2 3/4 3/4 3/4 3/4 LPG/Propane 3/4 3/4 3/4 3/4 3/4 3/4 3/4 Water supply size Water return size Drain size 2-/2 NPT 2-/2 NPT 3/4 NPT 20 volts - 60 hertz - phase (less than 2 amps) Shipping weight - lbs. package 325 404 483 564 649 79 800 OPTIONAL ACCESSORIES See Lennox Price Book For Complete Listing of Optional Accessories LPG/Propane Conversion Kit Standard Kit 57L60 54L59 54L6 54L63 54L65 54L67 54L69 High Altitude (over 5000 ft.) 57L6 54L60 54L62 54L64 54L66 54L68 54L70 Combustible Flooring Base 92P79 92P79 92P79 92P79 8P26 8P26 8P26 I=B=R ratings indicate the amount of equivalent direct radiation each boiler will produce under normal conditions and thermostatic control. Steam ratings based on an allowance of.333 in accordance with the factors shown on the I=B=R Standard as published by The Hydronics Institute. Selection of boiler size should be based on Net I=B=R Rating being equal to or greater than installed radiation in square feet (m2). 2 Annual Fuel Utilization Efficiency based on US DOE test procedures and FTC labeling regulations. HIGH ALTITUDE DERATE CSA certified units for the U.S. must be derated when installed at an elevation of more than 2000 feet above sea level. If unit is installed at an altitude higher than 2000 feet, the unit must be derated 4% for every 000 feet above sea level. Thus, at an altitude of 4000 feet, the unit would require a derate of 6%. NOTE - This is the only permissible derate for these units. / Page 4

DIMENSIONS - INCHES (MM) RELIEF VALVE VENT DAMPER (Furnished) A PRESSURE GAUGE 4-3/4 (2) 26-/2 (673) PRESSURE LIMIT CONTROL SUPPLY OUTLET TRANSFORMER WATER LINE 29 (737) HEAT EXCHANGER BURNERS 2-/4 (3) BLOCKED VENT SENSOR ROLLOUT SWITCH LOW WATER CUT-OFF PROBE 36-3/8 (924) IGNITION CONTROL SIGHT GLASS LOW WATER CUT-OFF GAS VALVE RETURN INLET 24 (60) LEFT SIDE VIEW FRONT VIEW RIGHT SIDE VIEW Model No. A in. mm -75 -/4 286-2 4-/2 368-50 7-3/4 45-87 2 533-225 24-/4 66-262 27-/2 699-299 30-3/4 78 INSTALLATION CLEARANCES - INCHES (MM) Side 6 (52) Gas Supply/Control Side 24 (60) Rear 6 (52) Top 6 (52) Service Clearance (Front) 24 (60) Floor *Combustible Flue Pipe 6 (52) NOTE - Air for combustion must conform to the methods outlined in the National Fuel Gas Code (NFPA 54/ ANSI-Z223.). NOTE - Flue sizing must conform to the methods outlined in the current National Fuel Gas Code (NFPA 54/ ANSI-Z223.) or applicable provisions of local building codes. Clearance for installation on combustible floor if optional combustible flooring base is installed between the boiler and the combustible floor. See Specifications Tables. / Page 5

REVISIONS Sections Document Description of Change Updated to new publishing software. No changes to data. Visit us at www.lennox.com For the latest technical information, www.lennoxcommercial.com Contact us at -800-4-LENNOX NOTE - Due to Lennox ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. 200 Lennox Industries, Inc.