Latitudes Global Studio

Similar documents
Carpenter Center Cambridge, MA DAYLIGHT AS A DESIGN FACTOR Anahita Anandam

West pedestrian entry to Car Park One with view of interior atrium. West elevation detail of elevator and stair of Car Park One.

City of Green Administration Building. Brian Koze November 12, Lighting Schematic Design Presentation

Packard Building. Downtown Anaheim Colony Park. Farmers Park. Packing District I-5. Packing House

Program Summary: A ,000 SF Program Statement: $46.41 $11,000,000 August 2013

Official Plan Review: Draft Built Form Policies

Carleton University. Nicol Building New Sprott School of Business. Design Brief and Planning Rationale. Carleton University

The Morphological Diagram: A comprehensive toll for design and analysis in Architecture

0128AP. Beauty sometimes is in not knowing.

Tech Report. September 9,

VISUAL RESOURCES 1. INTRODUCTION 2. EXISTING CONDITIONS. a. Visual Character

IRRAD - PHASE II RADIANT COOLING - DESIGNING FOR FLEXIBLE PARTITION OF SPACE

(DC1) Direct Development Control Provision DC1 Area 4

New Street Proposed Redevelopment Architecture & Urban Design Brief

8 October 14, 2015 Public Hearing

UPRISE. United Nations Environmental Council. designing the UN Headquarters for Sustainability in New York City by Tatjana M.

Windows Influence on Room Daylighting in Residential Buildings

SOCIAL SUSTAINABILITY RESPONSE POST ON GEORGIA 349 W GEORGIA ST REZONING APPLICATION REV 2 - UDP ADDENDUM

George Hotel application

1002 S. Vandeventer Ave: Drive-Thru Variance. Site Address: 1002 S. Vandeventer Ave. Request: Drive-Thru Variance. Company Name: White Castle

Interior Architecture Studio IV

Rethinking Bexley Hall

FRAMEWORK OF DESIGN REVIEW:

Bethesda Downtown Design Advisory Panel Submission Form

George Hotel application STAFF REVIEW COMMITTEE OF THE WHOLE JANUARY 14, 2014

NRG SYSTEMS, HINESBURG, VT

Lindsey Beane. Executive Summary

UNIVERSITY OF PENNSYLVANIA NEURAL AND BEHAVIORAL SCIENCES BUILDING 415 University Ave, Philadelphia, PA 19104

Request Modification of Conditions of a Conditional Use Permit approved October 14, Staff Recommendation Approval. Staff Planner Stephen White

ENGINEERING BUILDING UNIVERSITY OF CAPE TOWN

36 TFG Design Centre. In keeping with the spirit of TFG s (The Foschini Group) vision of becoming a leading clothing PROJECT

CPD Rules and Regulations. Arapahoe Square Zoning and Design Standards/Guidelines

WILLISTON CROSSING. Williams County, North Dakota MAJOR COMPREHENSIVE PLAN AMENDMENT PRESENTATION 01/27/2015

PROJECT DESCRIPTION & INTRODUCTION

COLLABORATION BETWEEN CITY, COUNTY, UNIVERSITY AND PROPERTY OWNERS

GENE FRIEND RECREATION CENTER Civic Design Review Concept Design DECEMBER14, 2015

Urban Design Brief Woodland Cemetery Funeral Home 493 Springbank Drive

University of California, San Diego Cal IT 2 Brian Smith. Schematic Design Presentation 06 December 2005

2016 Comprehensive Plan

CENTER FOR GREAT LAKES ECOLOGY 3

Shenzhen-Hong Kong International Center. Shenzhen, China

Perspectives of Sustainability A Cross-Disciplinary Conference

SITE PLANNING. USC Village will be a mixeduse urban environment. creating a common ground with the surrounding community. Our planning goals include:

Parcel 5. Level 1 Application March 12, Design Submittal POST ROAD RESIDENTIAL

2.18 MU Mixed Use District.

AIA Albuquerque 2016 Design Awards

ROSSLYN GATEWAY URBAN DESIGN MANUAL JULY 15, 2011 REVISED JANUARY 30, KOHN PEDERSEN FOX ASSOCIATES PC. All rights reserved.

Edward Pat Neal III Senior Interior Design Exhibit 2015

City of Redlands Architectural Guidelines for Non-Residential Development

SECOND AND UNIVERSITY SEATTLE, WASHINGTON

NEIGHBORHOOD 3: UNIVERSITY EDGE

2311 N GUNSIGHT DRIVE ST. GEORGE, UT 84770

Edward R. Sajecki Commissioner of Planning and Building. Region of Halton Proposed Regional Official Plan Amendment for 5768 Ninth Line

Harbour Way/Macdonald Avenue Master Development Richmond Community Redevelopment Agency

5.8 Visual Resources and Aesthetic Qualities

Plan.Develop.Grow W WINNEMAC AVE Chicago, Illinois 60625

URBAN DESIGN BRIEF Gordon Street City of Guelph. Prepared on behalf of Ontario Inc. March 25, Project No. 1507

Inspiration. Wall Street. Innovative Dynamic. Original. Established. Powerful Enlightened. Competitive. Modern. Intrigue

s including;

Technical Report One

WINDSOR GLEN DESIGN GUIDELINES

Urban Institute for Contemporary Arts

DRAFT PLAN OF SUBDIVISION PLANNING RATIONALE 5100 KANATA AVENUE CITY OF OTTAWA. Hawthorn Retirement Group MALONE GIVEN PARSONS LTD.

(c) DH-3 - Dixie Highway High Intensity Mixed-Use District (i) DH-3 - Dixie Highway High Intensity Mixed-Use District Use Table.

Intervention in the historical center of São Paulo

Art Deco on the Pond!

Architecture as a Transition Space

OPERATION AND MAINTENANCE INSTRUCTIONS FOR 6535 AND 6536 SERIES TWO TON PACKAGED HEAT PUMP

C l a y t o n ' s a t C o m m e r c e

Walnut Creek Transit Village Design Guidelines. Part Three III - 25

2018 DESIGN TRENDS COMMERCIAL ARCHITECTURE

IN THE BEGINNING PARK(ING) DAY, 2005

County of Los Angeles

DATE ISSUED: March 12, 2014 REPORT NO: 101. Old Globe Way Improvements and San Diego Zoo Employee Parking Structure

Human response to thermal environment in rooms with chilled beams

Architectural Standards

Lighting in the workplace is it just about vision?

1 N. Prospect Avenue Clarendon Hills, Illinois

RESIDENTIAL PLANNED UNIT DEVELOPMENT / SUBDIVISION AND REZONING CONCEPT AND DEVELOPMENT STAGE PLAN SUBMITTAL NARRATIVE

MULTIFAMILY RESIDENTIAL DESIGN PRINCIPLES Site Plan and Design Review Principles Checklist

Anatomy of A Vibrant Downtown. Anatomy of a Vibrant Downtown

Single Zone LCD Thermostat Operating Instructions

Case Municipal Planning Strategy and Land Use By-law Amendment Request Robie, College and Carlton Streets Halifax Peninsula PAC August 20, 2018

208 Holmwood Avenue - Brown s Inlet in the Glebe

THE AUGUST WILSON CENTER FOR AFRICAN AMERICAN CULTURE PITTSBURGH, PENNSYLVANIA. PERKINS + WILL chematic Design Presentation MICHAEL P.

PROPOSED WATERFRONT DISTRICT DESIGN STANDARDS

Design Rationale. Appendix E: Page 1 of 6. Building Form. site. bulk & height. views

DESIGN REVIEW COMMISSION AGENDA COEUR D ALENE PUBLIC LIBRARY LOWER LEVEL, COMMUNITY ROOM 702 E. MULLAN THURSDAY JANUARY 25, :00 pm

1. Avoid extensive blank walls that would detract from the experience and appearance of an active streetscape.

A P P E N D I X B - O P P O R T U N I T Y S I T E S

An ARTFUL CONTEMPORARY Sycamore Canyon Road Montecito, California

Presentation portfolio. Clichy-Batignolles O8 (2018)

REQUEST FOR EXPRESSION OF INTEREST

OPERATION AND MAINTENANCE INSTRUCTIONS FOR SERIES TWO TON PACKAGED HEAT PUMP

IMPORTANT NOTICE. Architectural Inventory Form COLORADO CULTURAL RESOURCE SURVEY I. IDENTIFICATION th Street 5WL.5601

WATERFRONT DISTRICT DESIGN STANDARDS

Agenda Report Meeting Date 08/01/18

Regency Developments. Urban Design Brief. Holyrood DC2 Rezoning

[PLANNING RATIONALE] For Site Plan Control and Lifting of Holding Zone By-Law 101 Champagne Avenue. May 23, 2014

NORDIC BUILT CHALLENGE NORWAY E C O N I C

Transcription:

Latitudes Global Studio Commercial Buildings in São Paulo SÃO PAULO NOVEMBER 2016 P re s e n t e d by G u i l h e r m e Re i s P ro d u c e d by A m a n d a Po b l e t, G u i l h e r m e Re i s a n d M a n u e l A l v a r e z

Case Study Condomínio Conjunto Nacional 1956 Edifício Itália 1965

Edifício Itália Condomínio Conjunto Nacional São Paulo 2016 N

Condomínio Conjunto Nacional Architect David Libeskind Opening 1956 Orientation Northeast Address Paulista Ave. 2073 27 floors 97,6 meters high 124.277,6 square meters Ceiling height 2,55 meters Reinforced concrete structures Pilotis Marquises Brise-soleil Opened ground plane N

History First establishment 1957 Conclusion of construction 1962 Preservation statement 2005 Condomínio Conjunto Nacional 1956

Urban Context Paulista Ave. 1950 Paulista Ave. 1970 Paulista Ave. 2016 (on Sundays) Skyline 2012

Architecture Vertical Block Horsa II Horsa I Guayupá Condomínio Conjunto Nacional 1956 Horizontal Block

14m 80,6m Architecture Commercial and Residential use Paulista Ave. Commercial use and Recreation area Shopping center Garage Condomínio Conjunto Nacional 1956 72m

Architecture Ground floor Condomínio Conjunto Nacional 1956

Architecture Terrace Condomínio Conjunto Nacional 1956

Architecture 24th floor (original) Condomínio Conjunto Nacional 1956

Measurements 24th floor Southwest facade (Santos Ave.) Administration Comunication Room Operational Department Summer and Winter 2016 Internal and External air temperature Globe temperature Internal and External Iluminace Relative humidity Airspeed Condomínio Conjunto Nacional 1956 24th floor (original)

Operational Department 3 occupants from 9h to 18h A computer for each desk White interior wall Partially opened shutters Artificial lights on Air conditioning on, setpoint between 20º and 24ºC Windows opened twice a week in the morning Glare at the end of the day

Operational Department Summer 2016 Partially opened shutters Artificial lights on Air conditioning on Windows opened twice a week in the morning

Operational Department Summer 2016 Partially opened shutters Artificial lights on Air conditioning on Windows opened twice a week in the morning

Operational Department Summer 2016 Partially opened shutters Artificial lights on Air conditioning on Windows opened twice a week in the morning

Operational Department Summer 2016 Partially opened shutters Artificial lights on Air conditioning on Windows opened twice a week in the morning

Operational Department Winter 2016 Partially opened shutters Artificial lights on Air conditioning on Windows opened twice a week in the morning

Operational Department Winter 2016 Partially opened shutters Artificial lights on Air conditioning on Windows opened twice a week in the morning

Operational Department Winter 2016 Partially opened shutters Artificial lights on Air conditioning on Windows opened twice a week in the morning

Comunication Room 2 occupants from 9h to 18h A computer for each desk White interior wall Partially opened shutters Artificial lights off Air conditioning off Windows closed No glare

Comunication Room Summer 2016 Partially opened shutters Artificial lights off Air conditioning off Windows closed

Comunication Room Summer 2016 Partially opened shutters Artificial lights off Air conditioning off Windows closed

Comunication Room Summer 2016 Partially opened shutters Artificial lights off Air conditioning off Windows closed

Comunication Room Summer 2016 Partially opened shutters Artificial lights off Air conditioning off Windows closed

Comunication Room Winter 2016 Partially opened shutters Artificial lights off Air conditioning off Windows closed

Comunication Room Winter 2016 Partially opened shutters Artificial lights off Air conditioning off Windows closed

Comunication Room Winter 2016 Partially opened shutters Artificial lights off Air conditioning off Windows closed

Edifício Itália Architect Adolf Franz Heep Opening 1965 Orientation East Adress Ipiranga Ave. 344 47 floors 151 meters high 52.000 square meters 4.000 Windows Ceiling hight 2,65 meters Movable brise-soleil 2nd tallest building in Sao Paulo

History Beginning of construction 1960 Preservation statement 1992 Conclusion of construction 1965 Edifício Itália 1965

Urban Context Downtown galleries (Sabrina Studart Costa, 2010) Edifício Itália 1965 Skyline 2015

Architecture Restaurant Commercial Use Circolo Italiano Commercial Center Theater Edifício Itália 1965

Architecture N N Ground floor 8th floor Edifício Itália 1965

Architecture Brise detail Section Edifício Itália 1965

Measurements 13th and 33th floor East and West facade Naturally ventiladed office (2015) Empty room (2016) Summer 2015 and Winter 2016 Internal and External air temperature Globe temperature Internal and External Iluminace Relative humidity Airspeed 13th floor N Edifício Itália 1965

13th 33th Floor Office 13th floor: 30 occupants from 9h to 18h A computer for each desk White interior wall Opened brise-soleils Artificial lights on Air conditioning off Windows opened N 33 th floor: 40 occupants 24h A computer for each desk White interior wall Closed brise-soleils Artificial lights on Air conditioning on Windows closed West facade (withou brise) East facade (withou brise)

13th Floor Office Summer 2015 Opened brise-soleils Artificial lights on Air conditioning off Windows opened West facade East facade

13th Floor Office Summer 2015 Opened brise-soleils Artificial lights on Air conditioning off Windows opened West facade East facade

13th Floor Office Summer 2015 Opened brise-soleils Artificial lights on Air conditioning off Windows opened West facade East facade

13th Floor Office Summer 2015 Opened brise-soleils Artificial lights on Air conditioning off Windows opened West facade East facade

33th Floor Office Summer 2015 Closed brise-soleils Artificial lights on Air conditioning on Windows closed West facade East facade

Empty Room East Facade: White interior wall Partially closed brise-soleils Artificial lights off Air conditioning off Windows closed West Facade: White interior wall Opened brise-soleils Artificial lights off Air conditioning off Windows opened N West facade (withou brise) East facade (withou brise) Brise study

Empty Room East Facade Winter 2016 Partially closed brisesoleils Artificial lights off Air conditioning off Windows closed

Empty Room West Facade Winter 2016 Opened brise-soleils Artificial lights off Air conditioning off Windows opened

Latitudes Global Studio Commercial Buildings in São Paulo SÃO PAULO NOVEMBER 2016