Better Air Dispersion for. Underfloor. Plenums

Similar documents
textile air dispersion products

UFAD and Displacement Ventilation. Dan Int-Hout, FASHRAE Chief Engineer Krueger Richardson, Texas

Raised Access Floor - (AE Breadth Area)

Displacement Ventilation

DESCRIPTION OF TECHNOLOGY

Radiant Exchange in Stratified Environments: Considerations and Challenges for Hourly Energy Simulation of UFAD, DV, and Radiant Cooling Systems

Underfloor Air Distribution in a Commercial High Rise: The New York Times Headquarters

Discover the. Advantages of DuctSox Air Dispersion

maximize displacement ventilation Opportunities

Underfloor Air Distribution:

Temperature Control and Zoning of UFAD Systems

UFAD Underfloor air distribution system

Operating Room Diffuser System with Integrated LED Lighting

Jim Aswegan Chief Engineer

IDL20e (2 way discharge) IDS60e (4 way discharge) Inffusers. UDI (vertical discharge) Frequently Asked Questions

Underfloor Air Systems. How It s Different: Overhead vs. Underfloor Air Systems

Underfloor Air Conditioning in North America David Arnold Troup Bywaters + Anders/ Director and Regional Chair ASHRAE Region at Large

UNDERFLOOR PRODUCTS E3

Space Air Diffusion II

Displacement Ventilation in Classrooms

ENGINEERING BULLETIN. Overview of Chilled Beam Technology. Purpose. Summary. Theory

Engineering Guide VAV Diffusers. Please refer to the Price Engineer s HVAC Handbook for more information on VAV Diffusers.

DUCTSOX-MENA MEGA PROJECTS BROCHURE

RITE-HITE FANS HVLS FANS A REVOLUTION. IN COST, COMFORT AND DESIGN.

GreenJet Transfer Fans

ASHRAE JOURNAL ON REHEAT

It's simple... we move more air for less! The Kelley FUSION fan circulates the greatest volume of air while consuming the least amount of energy.

Modular Active. Chilled. Beams

HAP e-help. Modeling Induction Beams in HAP v4.8 QB TIP 001

Fan System for Drop Ceilings

GreenPark. GreenJet Throw Performance

A REASONABLE ALTERNATIVE TO CHILLED BEAMS Dan Int-Hout Chief Engineer

RADIANT COOLING RESEARCH SCOPING STUDY

Yan Xue 1 and Qingyan Chen 2,1* Abstract

PDH & Professional Training

HVAC DISTRIBUTION and DELIVERY SYSTEMS

Making UFAD Systems Work BY STEVEN T. TAYLOR, P.E., FELLOW ASHRAE

design brief This design brief provides an introduction into the design and application of DV. It addresses the following issues:

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD

Technical Selection. elevent ceiling diffusers. Swirl, Jet, Louvred and Curved ceiling diffusers

The Performance of Diffuse Ceiling Inlet and other Room Air Distribution Systems Nielsen, Peter Vilhelm; Jakubowska, Ewa

Basic Hood Considerations The design process for a successful kitchen ventilation system starts when the engineering design HVAC team receives

Life Safety Damper Installation ASHRAE St Louis Chapter Feb. 9,2015. Peter McDonnell, PE, LEED AP BD+C McClure Engineering

Commercial Kitchen Ventilation (CKV) Design and Recent Innovations and Developments in the Industry.

AIR DISTRIBUTION. C. Section Building Automation and Control System Guidelines. D. Section Fire Alarm System & Detection Systems

Single Zone System. One duct system Used mostly in small buildings Forced air system All spaces controlled by a single thermostat Single air return

DALAMATIC DUST COLLECTORS

Air Conditioning Clinic

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

HVAC 101. H V A C S y s t e m s

SEMCO CHILLED BEAMS INDOOR AIR QUALITY AND ENERGY SAVINGS FANLESS FILTERLESS SPACE CONDITIONING

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Pulse Jet Baghouse ASTEC PULSE JET BAGHOUSE. for Asphalt Facilities

Air Management and Energy Savings with

VESDA ASPIRATING SMOKE DETECTION INDUSTRY GUIDE SUBSTATIONS

80-6-ISD A Better Solution for Proper Space Air Distribution

ADVANCING HVLS technology through controls and energy efficiency

Residential HVAC System Design

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

The Future In Air Distribution

PENDER Vario. PENDER Vario Line. PENDER Profi Line. PENDER Air Curtains. PENDER Airquell. Exhaust Technology.

Inffusers. idl20 (2 WAY) ids60 (4 WAY)

Air Movement for Energy-Efficient Comfort in Conditioned Spaces

Installation Guide. Model: IC15- MF Model: IC15- MFSilent Model: IC30- MF Model: IC30- MFSilent

FORM EG2 (502) FlexSys Configured Packaged Rooftop Air Conditioning Units

Appendix 13. Categories of Cooling and Heating systems

Fan Selection. and Energy Savings

APPLICATION GUIDE BEAMS

Halton - Meeting the Kitchen Ventilation challenges of multiple venues in Hotels, Casinos and Resorts

Liebert CW kW. Chilled Water Cooled Precision Air Conditioning For Data Centers. Precision Cooling For Business-Critical Continuity

Mixing Technologies Solutions for Flue Gas Desulfurization

NEW AR-L AR-C AND HIGH-CAPACITY LINEAR COOLING PANELS. Higher energy efficiency. Increased thermal comfort

The swirl comfort unit is a compact air-conditioning unit providing swirl jet air supply.

Introduction. Motor Types

SELF-SUFFICIENT AIR CARE FOR NEARLY MAINTENANCE-FREE VENTILATION IVEC ULTRA. Clean Air. Only Smarter.

SECTION DUCTWORK

4-Pipe VAV vs. Active Chilled Beams for Labs

Survey Says: Clean for Safety and Profitability

Technical Development Program COMMERCIAL HVAC SYSTEMS. Water Source Heat Pump Systems PRESENTED BY: Ray Chow. Sales Engineer

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

F25F Media Air Cleaner

B. Use UT Austin specifications and equipment schedule format for HVAC equipment where available.

Conducting a NFPA 652 Dust Hazard Analysis (DHA): Practical Tips & Approaches

Tunnel Transit Dampers. Heavy Duty Tunnel Transit Life Safety

UniTrane U-Line ductable water terminals Optimum efficiency with a sound reduction bonus

WHAT - HOW - WHY - WHERE PROTERCEILING RADIANT CHILLED CEILINGS COMFORT - EFFICIENCY - SAVINGS - AESTHETICS

Chilled Beams in Labs Eliminating Reheat & Saving Energy on a Budget

Second Revision No. 1-NFPA 90A-2016 [ Section No ] Submitter Information Verification. Committee Statement

MODEL: JRSVH SERIES JEAN S RESTAURANT SUPPLY 426 SOUTH STAPLES CORPUS CHRISTI, TEXAS PH: (361)

State-of-the-art Developments to Save Energy in Coating Drying

PRODUCTS TAO TAO PRODUCT: ADVANCING THE SCIENCE OF AIR DISTRIBUTION. temperature ambient optimizer. Redefine your comfort zone.

WHITE PAPER. ANSI/AHRI Standard for Fan and Coil Evaporators - Benefits and Costs

Linear Floor Heaters

ENGINEERING. Edition No. 13 October 2002

C. Manufactured double wall chimneys for fuel fired equipment. D. NFPA 54 - National Fuel Gas Code; National Fire Protection Association; 2009.

SMART DUCT SYSTEM. Caution: Do not tamper with the unit or its controls. Call a qualified service technician.

incorporating Contractors guide to car park ventilation A no-nonsense guide to the safe ventilation of underground and covered car parks

Aalborg Universitet. Diffuse Ceiling Inlet Systems and the Room Air Distribution Nielsen, Peter Vilhelm; Jensen, Rasmus Lund; Rong, Li

Transcription:

Better Air Dispersion for Underfloor Plenums

Uniform Air Mixing for UFAD Plenums Inlet Connection Zippered inlet collar secures to metal using DuctBelt and Anchor UFAD Technology UnderFloorSox (UFSoxTM) are DuctSox Fabric Air Dispersion Systems designed to distribute and disperse air to perimeter and high-heat load locations in Under Floor Air Distribution (UFAD) Systems. UFAD is a unique method for delivering conditioned air in offices and other commercial buildings. Unlike conventional overhead air-mixing systems, UFAD Systems use the space beneath the raised access floor as a plenum to introduce air into the occupied space, usually through special floor-mounted diffusers. Typical applications that employ UFAD design are in high tech office and business spaces utilizing cable for voice, power, and data transmission. Radius Elbow Unique elbow support and structure ensure alignment in standard floor grid UFAD Systems are becoming increasingly accepted in commercial building space as the benefits, which are well documented by ASHRAE, can include: UFAD system. Picture provided by Center for the Built Environment Improved employee comfort Reduced energy costs Improved indoor air quality Improved productivity and health Reduced floor to floor heights Reduced life cycle building costs Allows adjustment to release airflow as needed UFAD Models are based on Displacement Ventilation principles, requiring that the air stratifies from the floor to the ceiling, where it is either exhausted or recycled back into the space. New construction projects using UFAD Technology frequently qualify for LEED credits for increased ventilation effectiveness. One of the issues and challenges of UFAD Systems is thermal decay of the supply air to perimeter or special high-heat load zones. When this occurs, occupants in the warmer zones will generally increase the amount of air supply by adjusting their floor mounted diffusers. This can often lead to over mixing the air in the space causing destratification and possibly losing the benefits of UFAD technology. In some instances, system adjustments to accommodate perimeter zones result in overcooled interior zones. Challenges Patent Pending Custom per application, airflow dispersed through one or both sides for optimum performance Airflow Tag Application/product identification label Common sources of thermal decay. Picture provided by Center for the Built Environment To offset the loss in temperature and pressure for supply air over extended distances, designers have included the use of either air highways, ductwork, or more supply sources (chases or air towers) to convey conditioned air to those zones. While both options have benefits, they do have drawbacks to consider. Adding supply chases or air towers for an open floor plan, especially in large projects, can be very expensive and may be difficult to coordinate due to building design and floor layout limitations. Active Section UFAD UFSox Model More supply sources or air columns Additionally, these systems function by dispersing the airflow at high velocities which may create uneven pressure and temperature distribution. 6 F Perimeter Reduction with UFSox UFAD Open Plenum Model CFD model of a UFAD plenum with a metal supply with higher volume/velocity diffusers. Colors reflect temperature variation throughout the given floor plate. Image provided by Center for the Built Environment Reversing the Trend. Conventional UFAD design envokes a desire to minimize air distribution duct and For the test configurations studied, the results indicated that compared to an open plenum design, the use of DuctSox reduced thermal decay (temperature gain) in the perimeter zone. Overall, the temperature distribution within the plenum was more uniform with DuctSox. Adding DuctSox required some increased fan power, but this is still under investigation. Due to the promising results, CBE expects to conduct additional experiments on other DuctSox configurations. UFSox, with runs extending into the perimeter zone, reverse the thermal decay trend by introducing the coolest supply airflow where it is needed. In practice, these designs have allowed end users to control temperature without over-cooling the building core. Center for the Built Environment (CBE) at the University of California, Berkeley, have investigated the impact of distributing cool supply air into an underfloor plenum using DuctSox. Metal ductwork/air highway Airflow from ducted or air highway systems is not flexible and can create challenges for routing cable and reconfiguring office space. Full-scale Thermal Performance Tests, by the Comments on research provided by Fred Bauman, PE, Center for the Built Environment, University of California, Berkeley diffusers. Plenum airflow supply injection locations are commonly near the core of a building. In application, this has resulted in cooler supply air at the interior of the building than the perimeter. To account for the dispersion problem, facility managers either increase airflow volume or decrease supply air temperature. If your project or building suffers from a cold core, UFSox can mostly likely reverse the flow. Systems have been supplied retrofitting to existing air highway, duct, or open plenum designs. Contacting our engineering design team is the first step to improving the performance of your existing system. Figure 1. CFD of perimeter dispersion, CBE, UC Berkeley

Uniform Air Mixing for UFAD Plenums Inlet Connection Zippered inlet collar secures to metal using DuctBelt and Anchor UFAD Technology UnderFloorSox (UFSoxTM) are DuctSox Fabric Air Dispersion Systems designed to distribute and disperse air to perimeter and high-heat load locations in Under Floor Air Distribution (UFAD) Systems. UFAD is a unique method for delivering conditioned air in offices and other commercial buildings. Unlike conventional overhead air-mixing systems, UFAD Systems use the space beneath the raised access floor as a plenum to introduce air into the occupied space, usually through special floor-mounted diffusers. Typical applications that employ UFAD design are in high tech office and business spaces utilizing cable for voice, power, and data transmission. Radius Elbow Unique elbow support and structure ensure alignment in standard floor grid UFAD Systems are becoming increasingly accepted in commercial building space as the benefits, which are well documented by ASHRAE, can include: UFAD system. Picture provided by Center for the Built Environment Improved employee comfort Reduced energy costs Improved indoor air quality Improved productivity and health Reduced floor to floor heights Reduced life cycle building costs Allows adjustment to release airflow as needed UFAD Models are based on Displacement Ventilation principles, requiring that the air stratifies from the floor to the ceiling, where it is either exhausted or recycled back into the space. New construction projects using UFAD Technology frequently qualify for LEED credits for increased ventilation effectiveness. One of the issues and challenges of UFAD Systems is thermal decay of the supply air to perimeter or special high-heat load zones. When this occurs, occupants in the warmer zones will generally increase the amount of air supply by adjusting their floor mounted diffusers. This can often lead to over mixing the air in the space causing destratification and possibly losing the benefits of UFAD technology. In some instances, system adjustments to accommodate perimeter zones result in overcooled interior zones. Challenges Patent Pending Custom per application, airflow dispersed through one or both sides for optimum performance Airflow Tag Application/product identification label Common sources of thermal decay. Picture provided by Center for the Built Environment To offset the loss in temperature and pressure for supply air over extended distances, designers have included the use of either air highways, ductwork, or more supply sources (chases or air towers) to convey conditioned air to those zones. While both options have benefits, they do have drawbacks to consider. Adding supply chases or air towers for an open floor plan, especially in large projects, can be very expensive and may be difficult to coordinate due to building design and floor layout limitations. Active Section UFAD UFSox Model More supply sources or air columns Additionally, these systems function by dispersing the airflow at high velocities which may create uneven pressure and temperature distribution. 6 F Perimeter Reduction with UFSox UFAD Open Plenum Model CFD model of a UFAD plenum with a metal supply with higher volume/velocity diffusers. Colors reflect temperature variation throughout the given floor plate. Image provided by Center for the Built Environment Reversing the Trend. Conventional UFAD design envokes a desire to minimize air distribution duct and For the test configurations studied, the results indicated that compared to an open plenum design, the use of DuctSox reduced thermal decay (temperature gain) in the perimeter zone. Overall, the temperature distribution within the plenum was more uniform with DuctSox. Adding DuctSox required some increased fan power, but this is still under investigation. Due to the promising results, CBE expects to conduct additional experiments on other DuctSox configurations. UFSox, with runs extending into the perimeter zone, reverse the thermal decay trend by introducing the coolest supply airflow where it is needed. In practice, these designs have allowed end users to control temperature without over-cooling the building core. Center for the Built Environment (CBE) at the University of California, Berkeley, have investigated the impact of distributing cool supply air into an underfloor plenum using DuctSox. Metal ductwork/air highway Airflow from ducted or air highway systems is not flexible and can create challenges for routing cable and reconfiguring office space. Full-scale Thermal Performance Tests, by the Comments on research provided by Fred Bauman, PE, Center for the Built Environment, University of California, Berkeley diffusers. Plenum airflow supply injection locations are commonly near the core of a building. In application, this has resulted in cooler supply air at the interior of the building than the perimeter. To account for the dispersion problem, facility managers either increase airflow volume or decrease supply air temperature. If your project or building suffers from a cold core, UFSox can mostly likely reverse the flow. Systems have been supplied retrofitting to existing air highway, duct, or open plenum designs. Contacting our engineering design team is the first step to improving the performance of your existing system. Figure 1. CFD of perimeter dispersion, CBE, UC Berkeley

Uniform Air Mixing for UFAD Plenums Inlet Connection Zippered inlet collar secures to metal using DuctBelt and Anchor UFAD Technology UnderFloorSox (UFSoxTM) are DuctSox Fabric Air Dispersion Systems designed to distribute and disperse air to perimeter and high-heat load locations in Under Floor Air Distribution (UFAD) Systems. UFAD is a unique method for delivering conditioned air in offices and other commercial buildings. Unlike conventional overhead air-mixing systems, UFAD Systems use the space beneath the raised access floor as a plenum to introduce air into the occupied space, usually through special floor-mounted diffusers. Typical applications that employ UFAD design are in high tech office and business spaces utilizing cable for voice, power, and data transmission. Radius Elbow Unique elbow support and structure ensure alignment in standard floor grid UFAD Systems are becoming increasingly accepted in commercial building space as the benefits, which are well documented by ASHRAE, can include: UFAD system. Picture provided by Center for the Built Environment Improved employee comfort Reduced energy costs Improved indoor air quality Improved productivity and health Reduced floor to floor heights Reduced life cycle building costs Allows adjustment to release airflow as needed UFAD Models are based on Displacement Ventilation principles, requiring that the air stratifies from the floor to the ceiling, where it is either exhausted or recycled back into the space. New construction projects using UFAD Technology frequently qualify for LEED credits for increased ventilation effectiveness. One of the issues and challenges of UFAD Systems is thermal decay of the supply air to perimeter or special high-heat load zones. When this occurs, occupants in the warmer zones will generally increase the amount of air supply by adjusting their floor mounted diffusers. This can often lead to over mixing the air in the space causing destratification and possibly losing the benefits of UFAD technology. In some instances, system adjustments to accommodate perimeter zones result in overcooled interior zones. Challenges Patent Pending Custom per application, airflow dispersed through one or both sides for optimum performance Airflow Tag Application/product identification label Common sources of thermal decay. Picture provided by Center for the Built Environment To offset the loss in temperature and pressure for supply air over extended distances, designers have included the use of either air highways, ductwork, or more supply sources (chases or air towers) to convey conditioned air to those zones. While both options have benefits, they do have drawbacks to consider. Adding supply chases or air towers for an open floor plan, especially in large projects, can be very expensive and may be difficult to coordinate due to building design and floor layout limitations. Active Section UFAD UFSox Model More supply sources or air columns Additionally, these systems function by dispersing the airflow at high velocities which may create uneven pressure and temperature distribution. 6 F Perimeter Reduction with UFSox UFAD Open Plenum Model CFD model of a UFAD plenum with a metal supply with higher volume/velocity diffusers. Colors reflect temperature variation throughout the given floor plate. Image provided by Center for the Built Environment Reversing the Trend. Conventional UFAD design envokes a desire to minimize air distribution duct and For the test configurations studied, the results indicated that compared to an open plenum design, the use of DuctSox reduced thermal decay (temperature gain) in the perimeter zone. Overall, the temperature distribution within the plenum was more uniform with DuctSox. Adding DuctSox required some increased fan power, but this is still under investigation. Due to the promising results, CBE expects to conduct additional experiments on other DuctSox configurations. UFSox, with runs extending into the perimeter zone, reverse the thermal decay trend by introducing the coolest supply airflow where it is needed. In practice, these designs have allowed end users to control temperature without over-cooling the building core. Center for the Built Environment (CBE) at the University of California, Berkeley, have investigated the impact of distributing cool supply air into an underfloor plenum using DuctSox. Metal ductwork/air highway Airflow from ducted or air highway systems is not flexible and can create challenges for routing cable and reconfiguring office space. Full-scale Thermal Performance Tests, by the Comments on research provided by Fred Bauman, PE, Center for the Built Environment, University of California, Berkeley diffusers. Plenum airflow supply injection locations are commonly near the core of a building. In application, this has resulted in cooler supply air at the interior of the building than the perimeter. To account for the dispersion problem, facility managers either increase airflow volume or decrease supply air temperature. If your project or building suffers from a cold core, UFSox can mostly likely reverse the flow. Systems have been supplied retrofitting to existing air highway, duct, or open plenum designs. Contacting our engineering design team is the first step to improving the performance of your existing system. Figure 1. CFD of perimeter dispersion, CBE, UC Berkeley

UFSox are the best solution for UFAD Systems to supply air to perimeter and special high-heat load zones. The key advantages of UFSox are: Air Porous Fabrics. UFSox reduces heat loss (temperature gain) or thermal decay over extended distances and to perimeter zones. Additionally, porous fabrics eliminate the risk of condensation to the ductwork. Thermal gradient as air passes through porous fabric Elbow Support System Even Air Dispersion. This continues to be a significant feature and advantage of fabric air dispersion systems versus metal. Engineered vents and/or orifices and variable endcaps are designed to meet your application providing high entrainment ratios and uniform air dispersion patterns (low velocity). These advantages maintain temperature control both under and above the raised access flooring, especially in extended distance locations. Tests done at the Bio- Environmental and Structural Systems (BESS) Laboratory at the University of Illinois quantifies the temperature gradient or thermal barrier around the circumference of the ductwork. Inlet Attachment Simple Assembly & Installation. Lightweight, easy to handle and install Modular and zippered straight sections and fittings to meet the standard access floor height cavities from 12 to 18 (304mm to 458mm) UFSox lay on the floor and are positively located using tension cables at ends of straight runs and elbows Reconfigurable: Modular zippered sections allow for future re-design Lower Total Cost. UFSox Systems can be evaluated from both the initial investment and the lifetime ownership cost. Initial cost advantages of UFSox includes the cost of materials and installation related considerations (shipping, storage, handling, and installation labor). Lifetime ownership benefits are realized through efficiency of operation of the UFAD system. UFSox systems improve temperature consistency through floor devices and can reduce incidents of costly destratification. Consistent temperature within the UFAD plenum improves pressurization (balanced distribution), efficiency, and employee comfort. Actual smoke test of air permeable fabric showing thermal barrier and mixing with air dispersion jet Air Dispersion Air Porous Fabric Installation Cost

DuctSox Corporate Headquarters & Manufacturing Peosta, Iowa DuctSox Manufacturing Kunshan, China DuctSox Manufacturing Guadalajara, Mexico DuctSox products have been accepted within key industry organizations such as ASHRAE, Underwriters Laboratories (US & Canada), International Code Council, and by many building code authorities throughout the world. More than evolving our standard products, DuctSox strives to be the leader in the industry through our commitment to quality, service, and innovation. To better support our Global Distribution Network, we have expanded our production capabilities to Kunshan, China and Guadalajara, Mexico. Our commitment to INNOVATION provides unique products for many environments. Custom engineered air dispersion systems for open ceiling and finished ceiling applications. Unique air dispersion systems offer reduced discharge velocities for critical environments. Air dispersion systems for food preparation environments to eliminate drafts and condensation. Adjustable Fabric Air Dispersion System Simple and adjustable fabric air dispersion system assembled with pre-made components for open ceiling architecture. Air distribution device in accordance with flammability requirements of NFPA 90A <10km> Also classified in accordance with ICC evaluation service AC167 and UL subject 2518 For more information on DuctSox products, check us out at www.ductsox.com, or contact us at 866-382-8769! Products may be covered by one or more of the following patents: 6565430, 6558250, 5769708, 6425417, 6626754, 6280320, 6960130, 6958011, 6953396, and 8434526. Other patents pending. A Subsidiary of Rite-Hite Holding Corporation DSUFB0311C 2014 DuctSox Corp. 9866 Kapp Court Peosta, IA 52068 Ph: 866-382-8769 Fax: 563-588-5330 www.ductsox.com