CODESEC FIRE ALARM SYSTEMS. security technologies

Similar documents
Intelligent Addressable Fire Alarm System

Intelligent addressable fire alarm control panel

Solution F2. Fire Alarm Control Panels one step ahead.

Fire control panel detect 3004 plus and accessories

Addressable and Conventional Fire Protection

PANELS, KEYPADS & MODULES. Take Fire Protection to the Next Level Fire Products from DSC

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

GE Security. FP1200, FP2000 and KSA1200 series fire panels, repeaters and emulators Interconnection and wiring

IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide

Installation, Operating and Maintenance Manual

intelligent solutions

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Protec. Protec Algo-Tec TM 6500 Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network. Fire Detection - Addressable

Protec. Protec Algo-Tec TM 6500 Open Protocol Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network

NETWORK FIRE ALARM CONTROL PANEL. Features

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

Addressable Fire Alarm Control Panel

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

ACP10 & ACP50 Security Systems

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

IGD.CO.UK

Our technology, your peace-of-mind. Product list

Conventional Fire Alarm System 2014 V1.2

front cover Techno Fire & Safety Co. LLC

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Basic Fire Alarm SystemTraining. Arman Alnasar

Gas Controller Module GC-06

DS7400Xi Addressable Control/ Communicator

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

CONVENTIONAL >FIRE DETECTION C400 SYSTEM FIRE DETECTION

Solution F1. Fire Control Panels the new generation

INPUT / OUTPUT MINI MODULES

SALES SUPPORT DOCUMENT

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Intelligent Single Loop Fire Alarm Control Panel

PERMACONN PM1030 Includes DI300. Installation Manual

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

Wireless Fire & Security Solutions. Fire Product Showcase

TECHNICAL DATA SHEET ADDRESSABLE FIRE ALARM SYSTEMS FIRE ALARM CONTROL PANEL LF-6100 A 1/2

Integrated Security Solutions

Intelligent 2 & 4 Loop Fire Alarm Control Panels

INTRUDER ALARM SOLUTIONS PRODUCT LIST 2012

Fire alarm systems. detect. Fire fighting security systems

ADR Analog Addressable Fire Alarm Control Panel. Technical Manual. Control Panels. 3000En. En pdf

INTELLIGENT FIRE ALARM CONTROL PANEL

Planning Instructions MEW01776 Revision -

INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM. Features

5000 INSTALLATION GUIDE

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

TX7004. Intelligent Addressable Fire Alarm Control Panel Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

2013 Fire Alarm Systems Product catalogue

PRODUCT CATALOGUE. Cape Town 18 Darter Road Blue Water Estate Kommetjie. Gauteng 245 Louis Botha Avenue Orchards Johannesburg

NETWORK FIRE ALARM CONTROL PANEL. Features S7010 S :111

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

System 800 Addressable Fire Detection & Alarm System

FEC400 Series. Installation Manual

FC700A Fire detection control unit

Entwicklung + Fertigung + Service: Heerweg 15 D, Denkendorf Tel.: / Fax.: /

NU2 Smart Power Supply (SPS) Manual

The complete conventional fire warning system

Touchpoint Plus. A whole new control experience

AU MX Digital Loop Card Installation Instructions

DESIGN PHILOSOPHY FOR FIRE ALARM & DETECTION SYSTEM

Different types of Fire Alarm System

Planning Instructions MEW01090 Revision 4

FDMM01S - FDMM02 - FDMM10- FDMM11S FDMM12 - Input / output mini modules

MKTCTBLEFURTINC R001. Catalogue nd Edition

YOUR PARTNER IN FIRE & GAS DETECTION

Sita200plus. 200detectors. Single loop analogue addressable System

30.45 Electric Release PDRP-2001

Intelligent Security & Fire Ltd

IQ8Control C Fire Alarm Panel

TECHNICAL DATA OBSOLETE

TX7004. Intelligent Addressable Fire Alarm Control Panel Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

Who we are? - Nº 1 Spanish fire alarm systems manufacturer years experience in the fire detection field countries worldwide.

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

Interactive Fire Control Panel IFS7002 one signal loop Instruction Manual

ALARM... CONTROL... PANELS... AND... KEYPADS...- WIRED...

CATALOG NUMBER. Features. Description

561-MB256 plus. Intruder alarm control panel. Performance features

Touch Screen 1 loop Addressable Fire Alarm Panel

Integrated Security Solutions

sintra Sintra is a trademark of Asya Traffic INC.

Security Alarm Systems

security timeless design innovative products inspired technology

FDA241, FDA221 Siemens ASD

ELECTRONIC SOUNDER STROBE Model : AVD-C407

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

G SERIES: Security INTEGRATION as you want it. Greater expansion, communication, video integration, system resilience, and automation.

Fire Product Catalog

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

VAP304 PRO INSTALLATION & OPERATION MANUAL

SIMPLICITY CO CARBON MONOXIDE DETECTION & VENTILATION PANEL

RACK MONITORING SYSTEM - RAMOS Ultra

ANALOGUE ADDRESSABLE FIRE PANEL MAGPRO96 INSTALLATION AND PROGRAMMING MANUAL

Transcription:

CODESEC FIRE ALARM SYSTEMS security technologies

AA402 ADRESSABLE FIRE ALARM CONTROL PANEL AA402 Electronic Addressable Intelligent Fire Alarm Control Panel Onboard one loop, 250 nodes per loop, Metal Case, 128x64 Graphic LCD Display, 16 Zone Leds, Programmable Zone Contents, Alarm and Error Relay Outputs, Supervise Siren Output, 3 Open Collector Programmable Outputs, Event Log, Turkish and English Language, RS485 Serial Interface, Real Time Clock, EN54-2/4 Compatible. AA504 ADRESSABLE FIRE ALARM CONTROL PANEL AA504 Electronic Addressable Intelligent Fire Alarm Control Panel 1-4 Loops, 250-1000 Node Capacity, AA45R Repeater Connection, By LE505 Loop Extension Module can be extended to 16 Loops, Metal Case, 128x64 Graphic LCD Display, 16 Zone Leds, 250 Zones, Programmable Zone Contents, Alarm and Error Relay Outputs, Supervise Siren Output, 3 Open Collector Outputs, Event Log, Turkish and English Language, RS485 Serial Interface, Real Time Clock, EN54-2/4 Compatible. AA45R REPEATER PANEL AA45R Repeater Panel Compatible with AA504 FACPs, One to one simulation as panel, Very thin design, Metal Case, 128x64 Graphic LCD Display, 16 Zone Leds, RS485 Interface, No need extra card or device, Direct connection to FACP. Dimensions: 25,5x30,5x3cm LE505 LOOP EXTENSION MODULE LE505 Loop Extension Module Connection AA504 FACP extends 4 loop by module, 4 slots for LK401 Loop Card, Can be connected up to 3 modules per AA504, Selectable by DipSwitch 3 Loop groups ( 4 loops 3 modules) ( 5-8/9-12/13-16 Loop Selection), RS485 interface, Internal power supply, 2x 7Ah Battery Backup, LK401 Loop Card/Cards not included 3

LK401 LOOP CARD LK401 Loop Card One loop 250 node capacity, Short Circuit Protection, Indication Leds, ESD Protection, For use with AA504 FACP and LE505 Loop Extension Module, 32 pin connector, Short Circuit Protection. PRA5P PRINTER MODULE PRA5P Printer Module RS485 Interface with AA504 FACP, Dot Matrix output. PP201 ADDRESS PROGRAMMER PP201 Address Programmer Can programme all the devices that used in the system, 2x16 Alfanumeric LCD Display, Turkish and English Language, 4xAAA Battery, Short Circuit Protection, Identification of the address and type of the device. ER100 CONFIGURATION AND PROGRAMMING SOFTWARE ER100 Configuration and Programming Software Configuration and Programming of AA5xx Series FACPs, Turkish and English Language, RS485 Serial Interface 4

EP200 EP200 SUPERVISION AND CONTROL SOFTWARE EP200 Supervision and Control Software Configuration, Programming, Supervision and Control of AA5xx Series FACPs, Turkish and English Language, RS485 Serial Interface USB485 USB-RS485 CONVERTOR USB485 USB-RS485 Convertor USB - RS485 interface,usb Cable, RX TX leds. DD501 ADDRESSABLE OPTICAL SMOKE DETECTOR DD501 Addressable Intelligent Optical Smoke Detector Dual indicator with lightway, By intelligent property and self caibration eliminates false alarms, Indicator output, EN54-7 Certified. Diameter:10cm Height:4,4cm ED501 ADDRESSABLE OPTICAL SMOKE DETECTOR ED501 Addressable Intelligent Optical Smoke Detector Dual indicator with lightway, By intelligent property and self caibration eliminates false alarms, Indicator output, EN54-7 Certified. Diameter:10cm Height:4,4cm 5

DD502 ADDRESSABLE HEAT DETECTOR DD502 Addressable Heat Detector Two indication leds, By intelligent property and self caibration eliminates false alarms, Indicator Output, Class A1, EN54-5 Certified. Diameter:10cm Height:4,4cm DD512 ADDRESSABLE CONSTANT HIGH HEAT DETECTOR DD512 Addressable High Temperature Constant Heat Detector Two indication leds, By intelligent property and self caibration eliminates false alarms, Indicator Output, 78 C Constant Heat. Diameter:10cm Height:4,4cm DD503 ADDRESSABLE COMBINED DETECTOR DD503 Addressable Combined Optical Smoke and Heat Detector Combined Constant Temperature and Optical Smoke Perception, Two indication leds, By intelligent property and self caibration eliminates false alarms, Indicator Output, EN54-5/7 Certified. Diameter:10cm Height:4,4cm DD-T DETECTOR BASE FOR DD VE ED SERIES Detector Base for DD and ED series devices Stainless Steel Contact, Anti corrosion coating, ABS material, Four wall mount holes, Detector name bracket. 6

GS290 ADDRESSABLE GAS DETECTOR GS290 Addressable Gas Detector LPG and Natural Gas Detection, Optically Isolated, Alarm and Fault Supervision, Test Button, Lightway indication, Addressable Loop Connection, Low Power Consumption, EN12094-1 Certified. Dimensions: 9x9x3,8cm CO401 ADDRESSABLE CARBON MONOXIDE DETECTOR CO401 Addressable Carbonmonoxide Detector Carbonmonoxide Gas Detection, Optically Isolated, Alarm and Fault Supervision, Test Button, Lightway indication, Addressable Loop Connection. Dimensions: 9x9x3,8cm BM050 BEAM SMOKE DETECTOR BM050 Beam Detector 10-50 perception distance, Transmitter/Receiver, Reflector Included, User friendly Installation, Laser Pointer for easy adjustment, Selectable two different threshold level, Alarm and Error Relays Dimensions: 129 x 80 x 84 mm BM100 BEAM SMOKE DETECTOR BM100 Beam Detector 10-100 perception distance, Transmitter/Receiver, Reflector Included, User friendly Installation, Laser Pointer for easy adjustment, Selectable two different threshold level, Alarm and Error Relays Dimensions: 129 x 80 x 84 mm 7

SB508 SOUNDER DETECTOR BASE SB508 Sounder Detector Base Sounder Detector Base for DD and ED series devices. Microprocessor controlled, No need extra cable, If alarm perceived by the detector sounds 1 sec every 3 seconds. Diameter:10 cm Height:6mm SB604 SOUNDER DETECTOR BASE SB604 Sounder Detector Base Sounder Detector Base for DD and ED series devices. Microprocessor controlled, 87dB Sound Level, White ABS material. Diameter: 12cm Hight:4,3cm SB604F SOUNDER DETECTOR BASE WITH FLASHER SB604 Sounder Detector Base with Flasher Sounder Detector Base for DD and ED series devices. Microprocessor controlled, 87dB Sound Level, 4 animated Leds, Red Transparent ABS material. Diameter: 12cm Hight:4,3cm SB604O FLASHER DETECTOR BASE SB604O Flasher Detector Base Flasher Detector Base for DD and ED series devices, 4 animated Leds, Red Transparent ABS material. Diameter: 12cm Hight:4,3cm 8

CP211 ADDRESSABLE MANUAL CALL POINT RESETTABLE CP211 Addressable Manual Call Point Resettable Animated Lightway indication, resettable by key, Prevention Cover. EN54-11 Compatible. Dimensions: 9x9x2,7cm CP312 ADDRESSABLE MANUAL CALL POINT RESETTABLE CP312 Addressable Manual Call Point Resettable Light indication, resettable by key, With embedded Isolator, EN54-11 Compatible. Can be used as Conventional or Switch. Dimensions: 8,5x8,5x5,5cm (Including Back Case) IM201 ADDRESSABLE SUPERVISED SINGLE INPUT MODULE IM201 Addressable Supervised Single Input Module Supervised Input; Opencircuit, Shortcircuit, Alarm Condition Perception, Small Size, Easy installation, EN54-18 Compatible. Dimensions: 6x4x2cm OM301 ADDRESSABLE OUTPUT CONTROL MODULE OM301 Addressable Single Output Control Module Single Channel Output Module, Relay Output, Normally Closed/ Normally Open Terminals Small Size, Easy installation, EN54-18 Compatible. Dimensions: 6x4x2cm 9

OM213 ADDRESSABLE TRIPLE OUTPUT MODULE OM213 Addressable 3 Channel Relay Output Module 3 Relay Outputs, Normally Closed and Normally Open Contact Connectors for each Relay, Optical Isolation, Easy Installation, EN54-18 Compatible. Dimensions: 9x7x6cm IO404 ADDRESSABLE 4 IN 1 INPUT/OUTPUT MODULE IO404 Addressable 4 in 1 Input/Output Module Dip Switch selectable. Can be Input Module, Conventional Input Module, Output Module and Siren Supervised Output Module. When working as Output Module Normally Closed and Normally Open Contact Connectors for Relay, Optical Isolation, Easy Installation, EN54-18 Compatible. Dimensions: 9x7x6cm IO808 ADDRESSABLE 8 INPUT/OUTPUT MODULE SELECTABLE IO808 Input/Output Module 8 Selectable 8 different Input or Output Selectable, Working on Loop Power no external power needed, One address programmable, gets 8 consecutive addresses, 8 way can be selectable Input or Output by Dipswitch. Dimensions: 9x14x6cm IS101 SHORT CIRCUIT ISOLATOR IS101 Short Circuit Isolator To prevent Short Circuit on the Loop, Indicator Led Active control. Dimensions: 6x4x2cm 10

SA340F ADDRESSABLE INDOOR SOUNDER WITH FLASHER SR340F Loop Powered Addressable Indoor Sounder with Flasher No extra power needed, 300mA NiMh battery (not included), Internal charge from loop, 4 Led Animated, Red Transparent, Sound Pressure Level 95dBA at 1 meter, Alarm Loop Current < 15mA, EN54-3 Compatible, Fits DD-T Detector base. Diameter:10cm Height:6,5cm $ SA340 ADDRESSABLE LOOP POWERED INDOOR SOUNDER SA340 Loop Powered Addressable Indoor Sounder No extra power needed, 300mA NiMh battery (not included), Internal charge from loop, Red Colour, Sound Pressure Level 95dBA at 1 meter, Alarm Loop Current < 15mA, EN54-3 Compatible, Fits DD-T Detector base. Diameter:10cm Height:6,5cm SO240R-A ADDRESSABLE OUTDOOR FIRE ALARM SIREN WITH FLASHER SO240R-A Outdoor fire Alarm Siren with Flasher Outdoor Use IP65, High Sound pressure Level 120dBA at 1 meter, 12V 1.3 Battery backup (not included), Positive/negative trigger and Optical Isolated trigger input, Addressable Loop Connection, EN54-3 Compatible. Dimensions: 30x24x7cm 11

CONVENTIONAL FIRE ALARM SYSTEM CODESEC KA316 16 ZONE CONVENTIONAL FIRE ALARM CONTROL PANEL CODESEC KA316 16 Zone Conventional Fire Alarm Control Panel 16 Zones, 2x16 Alfanumeric LCD Display, Zone names can be written, Event Log with Time Stamp, Alarm, Shortcircuit and Opencircuit indication, Plastic front Case, Metal Body, Userfriendly installation and programming, Day/Night Mode, Non-volatile System Clock, 1 Supervised Siren Out, Alarm and Error relay Outputs, 24V Auxiliary Power Output, EN54-2/4 Compatible. English&Turkish CODESEC K8 8 ZONE CONVENTIONAL FIRE ALARM CONTROL PANEL CODESEC K8 8 Zone Conventional Fire Alarm Control Panel 8 Zones, 2x16 Alfanumeric LCD Display, Zone names can be written, Event Log with Time Stamp, Alarm, Shortcircuit and Opencircuit indication, Plastic front Case, Metal Body, Userfriendly installation and programming, Day/Night Mode, Non-volatile System Clock, 1 Supervised Siren Out, Alarm and Error relay Outputs, 24V Auxiliary Power Output, EN54-2/4 Compatible. English&Turkish CODESEC K4 4 ZONE CONVENTIONAL FIRE ALARM CONTROL PANEL CODESEC K4 4 Zone Conventional Fire Alarm Control Panel 4 Zones, 2x16 Alfanumeric LCD Display, Zone names can be written, Event Log with Time Stamp, Alarm, Shortcircuit and Opencircuit indication, Plastic front Case, Metal Body, Userfriendly installation and programming, Day/Night Mode, Non-volatile System Clock, 1 Supervised Siren Out, Alarm and Error relay Outputs, 24V Auxiliary Power Outputs, EN54-2/4 Compatible. English&Turkish CODESEC K8A 8 ZONE CONVENTIONAL FIRE ALARM CONTROL PANEL CODESEC K8A Conventional Fire Alarm Control Panel 8 Zone, Seperate Alarm, Shortcircuit, Opencircuit and Bypass Leds for each zone, Keylock for Access Level 1, Plastic Case, Userfriendly installation and programming, Day/Night Mode, RS232 Interface, 1 Supervised Siren Out, 3 Open Collector Outputs, Alarm and Error relay Outputs, 12V and 24V Auxiliary Power Outputs, EN54-2/4 Compatible. 13

CONVENTIONAL FIRE ALARM SYSTEM CODESEC K4A 4 ZONE CONVENTIONAL FIRE ALARM CONTROL PANEL CODESEC K4A Conventional Fire Alarm Control Panel 4 Zones, Seperate Alarm, Shortcircuit, Opencircuit and Bypass Leds for each zone, Keylock for Access Level 1, Plastic Case, Userfriendly installation and programming, Day/Night Mode, RS232 Interface, 1 Supervised Siren Out, 3 Open Collector Outputs, Alarm and Error relay Outputs, 12V and 24V Auxiliary Power Outputs, EN54-2/4 Compatible. PS120 PS120 POWER SUPPLY PS120 Power Supply EN54-4 Power Supply, 2x7Ah Battery, Ready, Ac Loss, Battery Error, Earth Fault Indicator Leds. Error Relay Output (Normally Closed/Open Terminals), Faulty Battery Indication, Battery Short Protection, Deep Discharge prevention, 100W Continuous Power. DK230 CONVENTIONAL OPTICAL SMOKE DETECTOR DK230 Conventional Optical Smoke Detector By intelligent property and self caibration eliminates false alarms, Operation indication; Flash Green Led every 10 seconds, Alarm dual Red Leds with lightway, Indicator output, Derived from DD501. EN54-7 Compatible. Diameter:10cm Height:4,4cm EK230 CONVENTIONAL OPTICAL SMOKE DETECTOR EK230 Conventional Optical Smoke Detector By intelligent property and self caibration eliminates false alarms, Operation indication; Flash Green Led every 10 seconds, Alarm dual Red Leds with lightway, Indicator output, Derived from ED501. EN54-7 Compatible. Diameter:10cm Height:4,4cm 14

CONVENTIONAL FIRE ALARM SYSTEM DK231 CONVENTIONAL HEAT DETECTOR DK231 Conventional Heat Detector Class A Heat Detector, Operation indication; Flash Green Led every 10 seconds, Alarm dual Red Leds with lightway, Indicator output, Derived from DD502. EN54-7 Compatible. Diameter:10cm Height:4,4cm DC232 CONVENTIONAL COMBINED OPTICAL SMOKE AND HEAT DETECTOR DC232 Conventional Combined Optical Smoke and Heat Detector By intelligent property and self calibration eliminates false alarms, Class A Heat Detector, Operation indication; Flash Green Led every 10 seconds, Alarm dual Red Leds with lightway, Indicator output. EN54-5/7 Compatible. Diameter:10 cm Height:4,4cm DD-T DETECTOR BASE FOR ED AND DD SERIES DEVICES Detector Base for DD and ED series devices Stainless Steel Contact, Anti corrosion coating, ABS material, Four wall mount holes, Detector name bracket. GS290K GAS DETECTOR WITH RELAY OUT GS290K Gas Detector with Relay Out LPG and Natural Gas Detection, Alarm and Fault Supervision, Test Button, Lightway indication, Normally Closed and Normally Open Contact Connectors for Relay EN12094 Compatible. Dimensions: 9x9x3,8cm 15

CONVENTIONAL FIRE ALARM SYSTEM CO401K CARBONMONOXIDE DETECTOR WITH RELAY OUT CO401K Relay Out Carbonmonoxide Detector Carbonmonoxide Gas Detection, Optically Isolated, Alarm and Fault Supervision, Test Button, Lightway indication, Normally Closed and Normally Open Contact Connectors for Relay. Dimensions: 9x9x3,8cm BM050 BEAM SMOKE DETECTOR BM050 Beam Smoke Detector 10-50 perception distance, Transmitter/Receiver, Reflector Included, User friendly Installation, Laser Pointer for easy adjustment, Selectable two different threshold level, Alarm and Error Relays Dimensions: 129 x 80 x 84 mm BM100 BEAM SMOKE DETECTOR BM100 Beam Smoke Detector 10-100 perception distance, Transmitter/Receiver, Reflector Included, User friendly Installation, Laser Pointer for easy adjustment, Selectable two different threshold level, Alarm and Error Relays Dimensions: 129 x 80 x 84 mm CK180 CONVENTIONAL RESETTABLE MANUAL CALL POINT CK180 Resettable Manual Call Point Animated Lightway indication, resettable by key, Prevention Cover, EN54-11 Compatible. Dimensions: 9x9x2,7cm 16

CONVENTIONAL FIRE ALARM SYSTEM CK312 CONVENTIONAL RESETTABLE MANUAL CALL POINT CK312 Conventional Resettable Manual Call Point Resettable by key, Led Indicator, EN54-11 Compatible. Dimensions: 8,5x8,5x5,5cm (Including Back Case) SR280 INDOOR SOUNDER WITH FLASHER SR280 Indoor Sounder with Flasher Indoor Sounder, Red Colour, Sound Pressure Level 85dBA at 1 meter, Alarm Current < 90mA, EN54-3 Compatible Dimensions: 9x9x3,4cm SR408 INDOOR SOUNDER SR408 Indoor Sounder Conventional Indoor Sounder, Red Colour, Sound Pressure Level 92dBA at 1 meter, Alarm Current < 32mA, EN54-3 Compatible, Fits DD-T Detector base Diameter:10cm Height:6,5cm SR408F INDOOR SOUNDER WITH FLASHER SR408F Indoor Sounder with Flasher Conventional Indoor Sounder, Red Transparent Colour, Four Anime Leds, Sound Pressure Level 92dBA at 1 meter, Alarm Current < 36mA, EN54-3 Compatible, Fits DD-T Detector base Diameter:10cm Height:6,5cm 17

CONVENTIONAL FIRE ALARM SYSTEM SO240R OUTDOOR FIRE ALARM SIREN WITH FLASHER SO240R Outdoor fire Alarm Siren with Flasher Outdoor Use IP65, High Sound pressure Level 120dBA at 1 meter, 12V 1.3 Battery backup (not included), Positive/negative trigger and Optical Isolated trigger input, Addressable Loop Connection optional (SO240R-A Model), EN54-3 Compatible. Dimensions: 30x24x7cm PL001 PARALLEL INDICATOR LED PL001 Parallel Indicator Led For use with Conventional and Addressable Detectors, Normally transparent, In alarm Red Led indication. Diameter: 8cm Height:1,8cm PL002 PARALLEL INDICATOR LED PL002 Parallel Indicator Led For use with Conventional and Addressable Detectors, In alarm Wide Red Illumination. Diameter: 8cm Height:1,8cm VD202 AUTOMATIC PSTN VOICE DIALER VD202 Automatic PSTN Voice Dialer 8 different call numbers, 20 seconds voice record, onboard buttons, Continuous/Trigger Call, 12Vdc Dimensions: 6x7,5cm 18

CONVENTIONAL FIRE ALARM SYSTEM S02 WATER LEAKAGE DETECTOR S02 Water Leakage Detector Water Leakage Detector, Current Limitting, Vertical, Horizontal and Cable Extension Installation, Buzzer Indication, Normally Open/Close Selectable Relay Output, Two colour Led Indication. Dimensions: 6x4x2cm BC712 BATTERY 12V/7Ah BC712 Battery 12V/7Ah ( B.B Battery ) VRLA Chargeable Sealed Lead Acid Battery Dimensions: 6x4x2cm KB208 1x2x0.8 FIRE CABLE KB408 2x2x0.8 FIRE CABLE KB208 1x2x0.8 mm2 Fire Cable KB408 2x2x0.8 mm2 Fire Cable KB215 1x2x1.5 FIRE CABLE KB415 2x2x1.5 FIRE CABLE KB215 1x2x1.5 mm2 Fire Cable KB415 2x2x1.5 mm2 Fire Cable 19