TECHNICAL DATA 3% AR-AFFF

Similar documents
A.U.P.C.I ASOCIACIÓN URUGUAYA DE PROTECCION CONTRA INCENDIO AUPCI

SECURITY BLANKET Foam Fire Protection Products

TECHNICAL DATA OBSOLETE

TECHNICAL DATA OBSOLETE

TECHNICAL DATA APPROVED SPRINKLERS FOR USE WITH FOAM CONCENTRATES 1. GENERAL DESCRIPTION 2. LISTINGS AND APPROVALS

Foam Products ENGLISH

II Brazilian Sprinkler Conference October 27-28, 2016

Foam Systems U.S. Quick Reference Guide

WILLIAM HICKS. MSc, CFEI, CFPS, IAAI-CFI, MIFireE, EFO, CFOD, F-IAFI. Associate Professor Eastern Kentucky University

The metering orifice is sized according to the type and percentage of concentrate used and is also secured with a stainless steel retaining ring)

Second Revision No. 11-NFPA [ Section No. 2.4 ] Submitter Information Verification. Committee Statement

Self Expanding Foam Fire Suppression System SPECIFICATION SHEET Rev

CITY OF MOBILE. Purchasing Department and Package Delivery: Government Plaza 4th Floor, Room S Government St Mobile, Alabama 36644

TECHNICAL DATA OBSOLETE

TECHNICAL DATA. Factory Mutual Approval is pending for the system as a whole.

An Overview Of Fluorinated Firefighting Foams: Past, Present & Future Presented by: Jerry Back, JENSEN HUGHES FOAM SYSTEM SYMPOSIUM

Tel Web: dyayan.com

Technical Article. Foam Systems - Low Expansion, Medium Expansion, High Expansion. Martin Workman, Product Manager Special Hazards Division

Creating A Global Industrial Leader

Foam Products. Quick Reference Guide EMEA. Trusted above all.

TECHNICAL DATA. Wet 26a. February 22, 2009

esfr pendent sprinkler vk510 (k25.2)

TECHNICAL DATA. * Refer the Approval Chart on page 120c and Design Criteria on page 120d for culus and FM approval requirements that must be followed.

A HISTORICAL REVIEW OF FLUORINATED FOAM FIREFIGHTING AGENTS, PERFORMANCE REQUIREMENTS/ ENVIRONMENTAL SAFEGUARDS REVIEW

TECHNICAL DATA OBSOLETE. * Refer the Approval Chart on page 121c and Design Criteria on page 121d for FM approval requirements that must be followed.

TECHNICAL DATA 1. SYSTEM DESCRIPTION 2. SYSTEM OPERATION 3. INSTALLATION. Page 1 of 5

freedom residential concealed pendent sprinkler vk474 (K5.8)

Technical Data Approvals UL Listed and FM Approved. Refer to Tables 1, 2, and 3, as applicable.

TECHNICAL DATA. * Refer the Approval Charts and Design Criteria on pages 3-5 for culus Listing and FM Approval requirements that must be followed.

& Fire Extinguisher Training

Foam Solutions, LLC Performance Parkway, Columbus, Ohio Ph ; Fax

TECHNICAL DATA. model c-2

MICROFAST AND MicrofastHP QUICK RESPONSE PENDENT SPRINKLERS TECHNICAL DATA

INSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA

TECHNICAL DATA OBSOLETE

BETACURE 100 CO-REACTANT

Industrial - Remote Reservoir Parts Cleaner Operator's Manual. Read and understand all labels, MSDS, and this instruction manual before use.

MODULE 2. Water-Based Suppression System Basics

TECHNICAL DATA. Viking Technical Data may be found on. The Viking Corporation s Web site at.

EMERGENCY PHONE: or (651) (24 hours)

esfr pendent sprinkler vk510 (k25.2)

Quick response concealed horizontal sidewall sprinkler VK481

sprinkler vk538 (K11.2)

TECHNICAL DATA. * Metric K-factor measurement shown is in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0.

micromatic standard response stainless steel sprinklers

TECHNICAL DATA OBSOLETE

FireFighter Antifreeze

Standard Spray concealed horizontal sidewall sprinkler VK481

Flammable and Combustible Liquids: Storage and Handling

Zep Dyna Clean Installation and Operator's Manual

FOAM MAKER MODEL - FMA & FMA-S HD FIRE PROTECT PVT. LTD. TECHNICAL DATA INSTALLATION, TESTING AND MAINTENANCE APPLICATION SPECIFICATION

EMERGENCY PHONE: or (651) (24 hours) Ingredient C.A.S. No. % by Wt POLYPROPYLENE

esfr dry pendent sprinkler Vk501 (k14.0)

FireIce & FireIce Shield F.A.Q.

HORIZON QUICK RESPONSE FLUSH PENDENT SPRINKLERS TECHNICAL DATA

mirage Quick response concealed pendent sprinkler vk465 (K4.2)

FOAM CHAMBER MODEL - FCA & FCA-S HD FIRE PROTECT PVT. LTD. TECHNICAL DATA FEATURES APPLICATION

Public Comment No. 2-NFPA [ Section No ]

FireFighter Antifreeze

ESFR PENDENT SPRINKLER VK500 (K14.0) TECHNICAL DATA

Refer to the specific sprinkler or spray nozzle technical data pages for sprinkler listings and approvals.

freedom residential concealed pendent lead free sprinkler

Technical Article. High Expansion Foam Systems. Martin Workman Viking Product Manager. September,

INDUSTRIAL - SOLVENT PARTS CLEANER CM200 (115V OR 230V PUMP)

Portable Fire Extinguishers

INSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA

Industrial - Remote Reservoir Parts Cleaner Operator's Manual. Read and understand all labels, MSDS, and this instruction manual before use.

ESFR PENDENT SPRINKLER VK510 (K25.2) TECHNICAL DATA

FUEL. Fire & Flammable Liquids Properties. Flammable & Combustible Liquid Safety. Safety. Practice. Laws: OSHA & NFPA. Safety.

The development Of the new CEN standard For fire fighting foam systems EN13565 Part 2

TECHNICAL DATA 1. PRODUCT NAME 2. DISTRIBUTOR 3. INTRODUCTION 4. FIELD OF APPLICATION 5. TECHNICAL DATA. Page 1 of 6

TYPES OF EXTINGUISHING AGENTS

microfast and microfasthp quick conventional sprinklers

STORED PRESSURE YES TEST STANDARDS: CAN/ULC S504 & ANSI/UL 229 CAN/ULC S508 & ANSI/UL 711. Available Options: Stationary Design Tow Loop

Transforming Challenges with Expertise. Total Protection. from concept to commissioning

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK460 (K5.8) TECHNICAL DATA

mirage Quick response concealed pendent sprinkler vk464 (K8.0)

MATERIAL SAFETY DATA SHEET 3M Tapes: 3900, 3939, 6969, 2929, 5959, 8979, 8979N, and /19/13

freedom residential concealed pendent sprinkler VK488 (K3.0)

Fire Suppression Solutions

TECHNICAL DATA OBSOLETE

TECHNICAL DATA NOTICE

esfr dry pendent sprinkler Vk502 (k14.0)

EC/QREC ORDINARY HAZARD PENDENT SPRINKLER VK572 (K14.0) TECHNICAL DATA

EMERGENCY PHONE: or (651) (24 hours)

Facility Safety Rules Hazard Communication Emergency Procedures Fire Safety. Safety Orientation

EMERGENCY PHONE: or (651) (24 hours)

ec/qrec ordinary hazard upright and pendent sprinklers vk570 and vk572 (k14.0)

micromatic standard sprinkler VK004 (K4.2) 3. technical data Page 1 of 6

FOAM CHAMBER MODEL - FCA & FCA-S TECHNICAL DATA FEATURES APPLICATION. Carbon Steel Construction FCA-65, FCA-80 & FCA-100. Stainless Steel Construction

culus Listed: Category VNIV Refer to the Approval Chart on page 3. VK697 Attic Upright Sprinkler Specifications:

Above Ground Fuel Tank Requirements

Fire Prevention Plan Program

TECHNICAL DATA DELUGE SYSTEM CONTROLLED BY ELECTRIC RELEASE

A Guide for Meeting NFPA 10 Subsection


standard response elo upright and pendent sprinklers (storage-density/area)

standard response elo upright sprinkler

TECHNICAL DATA. Refer to Approval Chart 1 and UL Design Criteria for culus Listing requirements that must be followed.

3M MATERIAL SAFETY DATA SHEET 3M(TM) Transpore(TM) Surgical Tape Cat. # 1527 series, 1527S-1, 1527S-2 04/07/2006

Transcription:

June 25, 21 Foam 14a The Viking Corporation, 21 N Industrial Park Drive, Hastings MI 4958 Telephone: 269-945-951 Technical Services: 877-384-5464 Fax: 269-818-168 Email: techsvcs@vikingcorp.com 1. DESCRIPTION Chemguard is a specially formulated, aqueous film forming free flowing viscous s. It forms a vapor suppressing aqueous film on hydrocarbon type fuels or a polymeric membrane on polar solvent/water miscible type fuels. is intended for use at a proportioning rate of 3% (3 parts CUG concentrate to 97 parts water) on hydrocarbon fuels such as gasoline, kerosene, diesel, etc., and on polar solvent/water miscible fuels such as alcohols, ketones, esters, etc. Features Type Approval: GB1538-94 Used at a 3% proportioning rate on both hydrocarbon and polar solvent fuels Suitable for use with either fresh or salt water Excellent wetting characteristics when used in combating Class A fuel fires Suitable for use with deluge and closed head foam water sprinkler systems Suitable for use with fiberglass, polyethylene or stainless steel. is not compatible with galvanized pipe or fittings in an undiluted form. Suitable for use with dry chemical extinguishing agents. Suitable for use with both air-aspirating foam and standard water fog nozzles 2. Listings and Approvals UL Listed FM Approved 3. Technical data A. Typical Properties (Not for specification purposes) Specific gravity @ 77 F (25 C): 1.2 Viscosity @ 77 F (25 C): Minimum storage temperature: Maximum storage temperature: 3-32 cps 35 F (2 C) 12 F (49 C) ph @ 77 F (25 C): 7.4 Appearance: Off white gel-like liquid Viking Technical Data may be found on The Viking Corporation s Web site at http://www.vikinggroupinc.com. The Web site may include a more recent edition of this Technical Data Page. Aspirating type discharge devices typically generate expansion ratios between 6-1 to 1 when is mixed with water at the correct ratio. Non- aspirating type devices will typically generate expansion ratios of between 2-4 to 1. Expansion ratios are dictated by the type of discharge device, flow rate and discharge pressure. B. Ordering Information 5-Gallon Pails (19 liters) 45 lb. (2.4 kg) Part No. F14972/5 55-Gallon Drums (28 liters) 495 lb. (224.5 kg) Part No. F14972/55 265-Gallon Tote (13 liters) 3 lb. (136.7 kg) Part No. F14972/265 4. Storage, STorAgE, Environmental, ENVIroNmENTAL, Proportioning ProPorTIoNINg AND and DISCHArgE Discharge DEVICES Devices A. Storage And Shelf Life If kept in the original unopened and airtight Chemguard supplied container and stored within the temperature range of 35 F- 12 F (2 C-49 C), a shelf life of between 2-25 years can be expected. If the AR-AFFF is to be stored in an atmospheric type storage tank whether on mobile apparatus or stationary, limit the airspace above the surface of the concentrate whenever possible and place a thin layer of quality mineral oil on the surface of the to minimize any effect from evaporation. The shelf life of any is maximized by proper storage conditions and maintenance. Factors affecting shelf life Form No. F_12797 Revised page replaces page 14a-e dated July 1, 29. (Updated weights.)

Foam 14b June 25, 21 The Viking Corporation, 21 N Industrial Park Drive, Hastings MI 4958 Telephone: 269-945-951 Technical Services: 877-384-5464 Fax: 269-818-168 Email: techsvcs@vikingcorp.com are wide temperature changes, extreme high or low temperatures, evaporation, dilution, and contamination by foreign materials. Properly stored AR-AFFF s have been tested and shown no significant loss of fire fighting performance, even after 15 years. Annual testing of all fire fighting foam is recommended by the National Fire Protection Association (NFPA). B. Environmental And Toxicological Information is biodegradable. However, as with any substance, care should be taken to prevent discharge from entering ground water, surface water, or storm drains. With advance notice, can be treated by local biological sewage treatment systems. Since facilities vary widely by location, disposal or discharge of concentrate or foam solution should be made in accordance with federal, state and local regulations. is a primary skin irritant. Repeated skin contact will remove oils from the skin and cause dryness. Ultraguard CUG is a primary eye irritant, and contact with the eyes should be avoided. Users are advised to wear protective equipment. If enters the eyes, flush them well with water and seek immediate medical attention. For further details, see the Material Safety Data Sheet. C. Proportioning Devices Fixed or portable in-line eductors In-line balanced pressure and pump pressure proportioning skid Bladder tank balanced pressure proportioning systems Around the pump proportioners Handline, air-aspirating nozzles with fixed eductor pickup tube D. Discharge Devices Foam Chambers - Models FC2.5, FC3 & FC4 are UL/FM Approved Standard water fog nozzles for handlines and monitors Air-aspirating foam nozzles Foam makers for use with either Floating Roof storage tanks or Dike/Bund protection systems Notice - can not be used for subsurface injection!! 5. Inspections, tests and maintenance NOTICE: The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to recognized standards such as those produced by NFPA, LPC, and VdS, which describe care and maintenance of sprinkler systems. In addition, the Authority Having Jurisdiction may have additional maintenance, testing and inspection requirements which must be followed. WARNING: Any system maintenance or testing which involves placing a control valve or detection system out of service may eliminate the Fire Protection of that system. Prior to proceeding, notify all Authorities Having Jurisdiction. Consideration should be given to employment of a Fire Patrol in the affected area. 6. Availability is available through a network of domestic and international distributors. See the Viking Corp. web site for closest distributor or contact The Viking Corporation. 7. Guarantee For details of warranty, refer to Viking s current list price schedule or contact Viking directly. Table 1: Application Rates Recommended top side application rate is.1 gpm/ft 2 or.15 gpm/ft 2 The following application rates are recommended for the specific fuel group listed. Fuel Minimum Application Rates Polar Solvent Fuels Hydrocarbon Fuels.1 gpm/ft. 2 IPA.15 gpm/ft. 2 Methanol.1 gpm/ft. 2 Ethanol.1 gpm/ft. 2 Methyl Ethyl Ketone.13 gpm/ft. 2 Ethyl Acetate.15 gpm/ft. 2 MTBE.15 gpm/ft. 2

June 25, 21 Foam 14c The Viking Corporation, 21 N Industrial Park Drive, Hastings MI 4958 Telephone: 269-945-951 Technical Services: 877-384-5464 Fax: 269-818-168 Email: techsvcs@vikingcorp.com Pressure Drop Vs. Flow for Sch. 4 Stainless Steel or Bronze Pipe 1-1/2" Pipe.26.24.22.2.18.16.14.12.1.8.6.4.2 2 4 6 8 1 12 14 16 Pressure Drop Vs. Flow for Sch. 4 Stainless Steel or Bronze Pipe 2" Pipe.2.18.16.14.12.1.8.6.4.2 5 1 15 2 25

Foam 14d June 25, 21 The Viking Corporation, 21 N Industrial Park Drive, Hastings MI 4958 Telephone: 269-945-951 Technical Services: 877-384-5464 Fax: 269-818-168 Email: techsvcs@vikingcorp.com Pressure Drop Vs. Flow for Sch. 4 Stainless Steel or Bronze Pipe 2-1/2" Pipe.16.14.12.1.8.6.4.2 5 1 15 2 25 3 35 4 Pressure Drop Vs. Flow for Sch. 4 Stainless Steel or Bronze Pipe 3" Pipe.12.1.8.6.4.2 1 2 3 4 5 6

June 25, 21 Foam 14e The Viking Corporation, 21 N Industrial Park Drive, Hastings MI 4958 Telephone: 269-945-951 Technical Services: 877-384-5464 Fax: 269-818-168 Email: techsvcs@vikingcorp.com Pressure Drop Vs. Flow for Sch. 4 Stainless Steel or Bronze Pipe 4" Pipe.8.7.6.5.4.3.2.1 1 2 3 4 5 6 7 8 9 1

This page intentionally left blank Form No. F_12797 Revised page replaces page 14a-e dated July 1, 29. (Updated weights.)