Safer. Smarter. Tyco. I wish I had a flexible FM Approved Water Mist Solution to fit any industrial oil cooker.

Similar documents
I wish I could protect my business with the most suitable Water Mist solution to fit my needs.

Safer.Smarter.Tyco. Watermist fire protection Technology you can trust

TN-25 Tunnel Fire Protection System. Safer. Smarter. Tyco.

Water Mist Fire Suppression

Simple On The Outside...

AQUAMIST Mist Control Center (MCC) Pump Skid Unit. General Description. Technical Data. Page 1 of 8 JANUARY 2016 TFP2270. Worldwide Contacts

Technical Data. Minimum Inlet Supply Pressure All MCC Models...0 psi. Minimum Inlet Supply Capacity Match system design calculations

Technical Data. Minimum Inlet Supply Pressure All MCC Models...0 psi. Minimum Inlet Supply Capacity Match system design calculations

STORAGE FIRE PROTECTION SPRINKLERS

Model CV-1F Grooved End Swing Check Valves. General Description. Technical Data. Installation. Page 1 of 6 FEBRUARY 2016 TFP1550. Worldwide Contacts

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, Dual-Purpose Water Supply, Domestic and Fire Sprinkler System General Description

Worldwide Contacts. Technical Data

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage

Sprinkler Solutions for Storage Applications

Machinery Space Fire Protection System from an Approved Product Portfolio

Technical Data. Sizes 2 12 Inch (DN50 DN300)

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

The metering orifice is sized according to the type and percentage of concentrate used and is also secured with a stainless steel retaining ring)

Water Mist Fire Protection Systems for the Protection of Industrial Oil Cookers. 8th March 2016 Dr Tim Nichols CPhys MIFireE

RAPID RESPONSE Series LFII Residential Sprinklers 5.8 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems

Series DS-1 Stainless Steel Dry-Type Sprinklers 5.6K Pendent, HSW, and Extended Coverage HSW Standard and Quick Response General Description

Series EC K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description

Series TY-B 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description

Solutions at every turn.

Series TY-FRL 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick & Standard Response (Light Hazard) General Description

RAPID RESPONSE Series LFII Residential Sprinklers 5.6 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems

proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System Application

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright and Pendent Extended Coverage Light and Ordinary Hazard General Description

proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System Application

Tyco Fire Valves Pure Performance

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Horizontal Sidewall Wet Pipe and Dry Pipe Systems General Description

Series TY-B 5.6 and 8.0 K-factor Upright and Pendent Intermediate Level Sprinklers Standard Response General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Flush Horizontal Sidewall Wet Pipe Systems

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Domed-Plate Concealed Pendent Wet Pipe and Dry Pipe Systems General Description

Model WS Specific Application Window Sprinklers Horizontal and Pendent Vertical Sidewall 5.6 K-factor General Description

Technical Data. Sizes: ANSI Inches (DN) 2-1/2 (DN65), 3 (DN80), 4 (DN100), 5 (DN125), 6 (DN150), 8 (DN200), 10 (DN250)

Fire Protection Products Technical Data Book Table of Contents, August 2017

Submittal Packages Detailed with Items and Reviewers

Model ESFR K-factor Pendent Sprinkler Early Suppression, Fast Response General Description. Sprinkler Identification Number (SIN)

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

WRENCH FLATS 1/2" NPT. 7/16" (11,1 mm) NOMINAL MAKE-IN CENTERLINE OF WATERWAY ESCUTCHEON PLATE SEATING SURFACE

Series TY-FRL 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

Model SW-20 and SW K-factor Extended Coverage Ordinary Hazard Horizontal Sidewall Sprinklers (Standard Response)

Model TY-FRFS, TY-FS Special, and TY-FS 57, 80, and 115 K-factor Upright and Pendent Flat Spray Sprinklers General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Flat-Plate Concealed Pendent Wet Pipe and Dry Pipe Systems General Description

Series TY-FRB 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Quick Response, Standard Coverage General Description

ESCUTCHEON PLATE SEATING 3/4" NPT SURFACE. 1-1/2" (38,1 mm) CROSS SECTION PENDENT RECESSED PENDENT

WRENCH FLATS 1/2" NPT. 7/16" (11,1 mm) NOMINAL MAKE-IN CENTERLINE OF WATERWAY ESCUTCHEON PLATE SEATING SURFACE

Sprinkler Identification Numbers. TY3351 Horizontal TY3451 Vertical. Technical Data

Technical Data. Working Pressure Range 20 to 250 psi (1,4 to 17,2 bar)

Series TY-B 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Standard Response, Standard Coverage General Description

Sprinkler Identification Numbers

Worldwide Contacts.

Model TY-FRFS, TY-FS Special, and TY-FS Flat Spray Sprinklers, Upright and Pendent 57, 80, and 115 K-factor General Description

RAPID RESPONSE Series LFII Residential 4.9 K-factor Concealed Pendent Sprinkler Flat Plate, Wet Pipe and Dry Pipe Systems General Description

Technical Data. Approvals The 1-1/2 thru 8 inch (DN40 thru DN200) DV-5 Red-E Cabinets are UL Listed and C-UL Listed with the following system types:

WRENCH FLATS NPT 1/2" 7/16" (11,1 mm) NOMINAL MAKE-IN. 1-1/2" (38,1 mm) 2-3/16" (55,6 mm) WRENCH NPT. (12,7 mm) NOMINAL MAKE-IN.

RAPID RESPONSE Series LFII Residential Sprinkler 4.4 K-factor Horizontal Sidewall, Dry Type Wet Pipe System General Description

VIZOR Electronic Dry Pipe Accelerator (EDPA) Quick-Opening Device for Dry Pipe Systems General Description

Series EC K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description

special request FACTORY ASSEMBLED UPRIGHT WITH SCREW FIELD ASSEMBLED MODEL S2 SHIELD (SEE INSTALLATION SECTION) WRENCH FLATS *

Technical Data. Sizes 2 in. (DN50) to 16 in. (DN400) Approvals UL and ULC Listed FM Approved

AESTHETIC SPRINKLERS.

Model ESFR K-factor Dry Type Pendent Sprinklers Early Suppression, Fast Response General Description

FIRE PROTECTION, NATURALLY AQUASONIC Water-Atomizing Fire Suppression System

Sprinkler Identification Number (SIN)

FIGURE 1 MODEL RFIII ECLH CONCEALED HSW SPRINKLER ASSEMBLY AND FEATURES. 5/16" (7,9 mm) MIN. 9/16" (14,3 mm) MAX.

Sprinkler Identification Numbers

Series ELO K-factor Upright and Pendent Sprinklers Standard Response, Standard Coverage General Description

ESCUTCHEON PLATE SEATING SURFACE. 1-11/16" (42,7 mm) CROSS SECTION

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

Technical Data. Approvals The 1-1/2 in. to 8 in. (DN40 to DN200) DV-5 Red-E Cabinets are UL Listed and C-UL Listed with the following system types:

O-RING UPRIGHT SHIELD WRENCH FLATS WRENCH FLATS FIGURE 1 SERIES TY-B UPRIGHT (TY3153) AND PENDENT (TY3251) SPRINKLERS

Technical Data. Outlet Connections (Ref. Figure 2) ISO 7-Rc 3/8 1/2 inch NPT 3/4 inch NPT. Nominal Assembly Lengths Ref. Table A

Sprinkler Identification Number. Page 1 of 6 AUGUST 2018 TFP288. Worldwide Contacts.

Model SW-20 and SW K-factor Extended Coverage Ordinary Hazard Horizontal Sidewall Sprinklers (Standard Response) General Description

DV-5 Red-E Cabinet Integrated Deluge Fire Protection Package. General Description. Technical Data. Page 1 of 6 AUGUST 2018 TFP1300. Worldwide Contacts

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Recessed Pendent, Dry Type Wet Pipe and Dry Pipe Systems General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Recessed Pendent, Dry Type Wet Pipe and Dry Pipe Systems General Description

Page 1 of 8 DECEMBER 2018 TFP408. Worldwide Contacts.

Model CV-1FR Riser Check Valves 2 to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data. Page 1 of 6 OCTOBER 2010 TFP950

The Protection of Machinery Spaces by means of the Local Application of Water Mist. Dr. Tim R. Nichols CPhys FIFireE

Series TY-B 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Standard Response, Standard Coverage General Description

FM Approvals & Water Mist Systems. Paul Bardsley Engineer, FM Approvals

Connected: Global protection, all together

Model ESFR K-factor Dry Type Pendent Sprinklers Early Suppression, Fast Response General Description

RAPID RESPONSE Series LFII Residential Sprinkler 4.4 K-factor Horizontal Sidewall, Dry Type Wet Pipe System General Description

Residential Fire Protection Sprinklers & Systems

RAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) General Description.

ADDITIONAL PRODUCTS 65

RAVEN 5.6K Institutional Sprinklers Pendent and Horizontal Sidewall Quick Response, Standard and Extended Coverage General Description

* Temperature rating is FIGURE K-FACTOR QUICK RESPONSE SERIES TY-FRB HORIZONTAL SIDEWALL (TY3331) SPRINKLERS

G3/8" DIN ISO 228 THREAD SHOULDER AND DUST CAP MATING SURFACE. STYLE H ESCUTCHEON (SEPARATELY ORDERED) 85 mm DIA. (3-3/8")

Rick Seidel Fike Corporation Regional Sales Manager

RAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) General Description

as required for residential sprinklers intended for use in dry pipe systems.

Worldwide Contacts.

THE WORLD LEADER. in special hazard fire suppression solutions

Model AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description

FIRE PROTECTION SYSTEM FOR INDUSTRIAL KITCHENS

Transcription:

I wish I had a flexible FM Approved Water Mist Solution to fit any industrial oil cooker.

I wish I could protect my industrial fryer installation with a fire protection solution that helps minimize collateral damage and helps achieve business continuity. (BUSINESS OWNER) I wish I could offer customers the best Water Mist solution to meet their installation needs, from a choice of Industrial Fryer Protection (IFP) systems. (CONTRACTOR/ENGINEER) I wish my policy holders could have a reliable Low Pressure FM Approved solution for their industrial fryer installation requirements. (AHJ/INSURER)

Wish granted! FM Approved Water Mist Solution for Industrial Fryer Protection (IFP) AquaMist IFP from Tyco provides flexible fire protection solutions for even the most stringent project requirements Ease of installation, dependability and comprehensive approvals are combined for cost-effective solutions AquaMist IFP helps minimize repair and cleaning costs, as well as downtime in the event of a fire FM Approved solution Fully integrated solution for compatibility between detection and suppression systems For more information visit www.tycoaquamist.com

IFP: Industrial Fryer Protection Flexible IFP solution to fit any oil cooker installation Tyco Addressable Fire Alarm Control Panel Pump Skid System (MCC Unit) AM4 Nozzle System Strainer Supply to additional fryers Tyco AquaMist IFP Zone Control Valve Cabinet Customized IFP Nozzles: Alarm AM31 Nozzle AM10 Nozzle 1 2 3 Industrial fryers are cookers commonly used in the food industry to produce consumables, such as breaded meats, potato products and pre-cooked snacks. They contain large amounts of cooking oil (up to 19,000 litres or 5,000 US gallons) and operate at temperatures of up to 354 C (670 F). This combination of extreme heat and fuel source can create a significant fire risk. Fire can occur if oil reaches its auto ignition temperature (AIT), or if ignition sources are introduced above the flash point. Large volumes of oil, once heated, maintain high temperatures and therefore fire risk for a long time. Cooling the oil is critical to help avoid re-ignition. This can be difficult, considering the energy efficient design of modern industrial oil cookers, which makes cooling a slow process. A fire incident presents a major risk to any business. Fire can affect operations across entire facilities, causing potential loss of equipment, assets and production time. Fire incidents in the food industry tend to be especially costly due to stringent food hygiene policies and the mission critical nature of the fryer. AquaMist IFP Solutions offer cost savings to manufacturing businesses and insurance companies via reduced downtime and minimized clean-up costs. Tyco AquaMist Industrial Fryer Protection (IFP) is an oil cooker fire suppression solution, which can be utilized for large and small-scale industrial applications. Available as a centralized electric pump, or localized stand-alone water supply, AquaMist is flexible enough to protect the largest and smallest applications cost effectively. AquaMist IFP includes Water Mist nozzles, combined with Fire Detection technology to provide an integrated solution to help protect the hood area, fines box and exhaust stacks. AquaMist IFP is tested and approved by FM. To obtain FM approvals, Water Mist must provide full extinguishment in various fryer configurations, including hood up and hood down arrangements. Water supply for standard or large-scale IFP can be provided by a Tyco Mist Control Center (MCC). The MCC is a Pump-based Skid Solution. Alternatively, a stand-alone IFP water supply can be provided by the Tyco Red-E Mist Supply Skid System. Large-Scale IFP Low pressure Water Mist solution for multiple oil cookers The Tyco MCC-based AquaMist IFP System is recommended to help protect multiple oil cookers in large-scale industrial applications. The MCC Pump Skid Package is the self-contained Control Center of the AquaMist System. The compact skid unit has been designed and assembled to ease system installation and to meet the most stringent project requirements. Advantages: High flexibility of nozzle installation reduces costs Extensive fire test program designed to perform in multiple scenarios Fully integrated solution for compatibility between detection and suppression systems FM Approved 7 5 3 1 4 AM31 Recessed Nozzle Key Features: Tech Datasheet (TFP2202) (nozzle) and TFP2242 (recessed fitting) Provides protection to the hood and outlet K = 0.30 GPM/psi1/2 (4.3 LPM/bar1/2) Min press: 170 psi (11.7 bar) Max press: 250 psi (17.2 bar) Water Density: 0.2 gpm / ft² / ( 8 lpm / m²) ¾ NPT threaded / ¾NPS socket weld for quick installation and easy maintenances Include a cap/chain for cleanliness and to prevent blockage. Also available with high temperature plug Optional protective cap to prevent nozzle blockage and oil contamination Material: Stainless Steel AM10 Nozzle AM10 Key Features: Tech Datasheet (TFP2210) Protection for the fines box K = 0.24 GPM/psi1/2 (3.5 LPM/bar1/2) Min press 170psi (11.7 bar) Max press 250psi (17.2 bar) Water Density ½ inch NPT Thread Connection Stainless Steel Available with recess fitting or high temperature material blow-off cap for quick installation and ease of maintenance AM4 Nozzle AM4 Key Features: Tech Datasheet (TFP2204) Protection for the exhaust stacks K = 0.24 GPM/psi1/2 (3.5 LPM/bar1/2) Min press 155psi (10.7 bar) Max press 250psi (17.2 bar) Water Density ½ inch NPT Thread Connection Stainless Steel High temperature material blow-off cap Industrial Fryer Protection (IFP) Options The fire protection solutions that can be used are CO 2, Water Spray and Water Mist. The industry accreditations, advantages and disadvantages of each solution are summarized in the table below: AGENT INDUSTRY STANDARDS ADVANTAGES DISADVANTAGES CO 2 NFPA12 BS5839 Part 4/ CEA4007/ISO6183 Water Spray IFP Components FM Approved (for water density of 20mm and above) Cost-effective Cost-effective Water Mist FM5560 / BS8489 High cooling effect Low water consumption The Aquamist solution consists of: Customized IFP nozzles Customized valve assembly Red-E Mist Supply Skid stand-alone IFP solution AquaMist pump skid system (MCC Unit) large-scale IFP solution Fully integrated fire detection technology H&S issues Reduced cooling effect Not supported by FM High risk of thermal shock Flood risk High water consumption Increased installation costs Stand-Alone IFP Specially designed to protect 1 or 2 oil cookers The stand-alone IFP AquaMist solution is a low pressure FM Approved Water Mist fire suppression solution for small-scale industrial fryer applications, where specifically only 1 or 2 oil cookers are required. The solution offers fire protection for minimum installation requirements and is the only low pressure FM Approved solution on the market. The Red-E Mist Supply Skid, an important component of the system, is available in two sizes. The 600 gallon (2271 liter) skid consists of one 600 gallon (2271 liter) water tank with four (4) nitrogen cylinders and can supply a system with flow demand up to 60 gpm (227 lpm) for a duration of 10 minutes. The 1200 gallon skid consists of two (2) 600 gallon (2271 liter) water tanks with eight (8) nitrogen cylinders and can supply a system with a flow demand up to 120 gpm (454 lpm) for 10 minutes. Advantages: Does not require external electrical supply Ideal to protect 1 or 2 oil cookers Does not require separate water tank or supply FM Approved MCC-Based AquaMist IFP System For large scale industrial applications (i.e. multiple cookers) (TFP2240) Water supply for small-scale applications (1 or 2 cookers) is provided by the Tyco Red-E Mist Supply Skid System (TFP2241). Not to be used in conjunction with Zone Control Valve Cabinet. 6 Fryer 2 Fines Box 4 5 6 Zone Control Valve Cabinet Key Features: Tech Datasheet (TFP2250) Hood: 1 ½ NPS Flange Fines Box: ¾ NPS Flange Dual mode operation: full system and fines box only All stainless steel components within NEMA 4x enclosure for caustic wash-down Integrated electronics (I/O modules, release peripherals, etc.) Valve cabinet is not needed for stand alone version Fully Integrated Fire Detection Technology Copyright 2016 Tyco Fire Products LP. All rights reserved. FM is a trademark of its respective owner. 7 Pump Skid System (MCC Unit) Key Features - EMCC Pump skid Tech Datasheet (TFP2270) 3 sizes: 50, 100, 150 gpm Wet Valve version for IFP applications Customized for voltage, frequency, etc, compatibility FM Approved for use with Tyco AquaMist IFP systems NFPA 20 compliant Pump start on demand Red-E Mist Supply Skid Key Features - Red-E Mist Supply Skid Tech Datasheet (TFP2272) Utilizes intermediate pressure single-fluid atomizing technology to generate a fine water spray Full system discharge to all protected portions of the industrial fryer equipment Cross zone automatic fire detection and control system Detection and Controls Addressable detection architecture can be utilized. Conventional architecture permitted with Red-E Mist Supply Skid Control panel options at customer s choice - FM All components to be either FM Approved or CE marked (Europe) Off the shelf components Control Panel Options Simplex 4010ES AutoPulse Z30-AR

Global strength. Local expertise. At your service WORLDWIDE HEADQUARTERS Tyco Fire Protection Products, 1400 Pennbrook Parkway, Lansdale, PA 19446, Tel: +1 215-362-0700, (Toll Free) Tel: +1 800-558-5236, Fax: +1 800-877-1295 www.tyco-fire.com EMEA - ENSCHEDE Kopersteden 1, P.O. Box 198, 7500 AD Enschede, The Netherlands, Tel. +31 (0)53-428-4444 www.tfppemea.com APAC - SINGAPORE Tyco Fire Protection Products, 2 Serangoon North Avenue 5, #07-01, Singapore 554911 Tel. +65-6577-4360, Fax: +65-6481-8791 www.tyco-fire.com www.tycoaquamist.com Email: aquamist@tycoint.com Copyright 2016 Tyco Fire Products LP. All rights reserved