ID Technology. Using Label Printer Applicators in Harsh Operating Environments. Bruce Richards, Technical Sales Coordinator

Similar documents
DIVISION 15 MECHANICAL

AlarmLine Linear Heat Detector

ROAM DCM Control Specification Guideline Division 16520

Bag Sealers Vacuum Sealers Vacuum Chambers Band Sealers Medical Packaging Flow Wrappers

Ink Degasser for Pro-HP Bulk System Installation and Operation Manual

Cabinet Cooler Systems

Alternative Fuel Fueling Stations

Air Duct Housings. Description

POWERFUL CUSTOMIZED SOLUTIONS UNMATCHED QUALITY

Fiber Optic Cleaning Overview. Prepared by Steve Lytle, Westover Scientific March 10 th, 2004

25W Explosion Proof Surface Mount LED Light - C1D1-2 - C2D1-2 - Aluminum Frame V AC

Ultrasonic Humidification System Model 5462 & Model 5472 OPERATING MANUAL

PRETREATMENT & CHEMICAL APPLICATION SYSTEMS

Lead-Lined Cabinetry. 7 Vreeland Road, Florham Park, NJ or

HOW LIMIT AND BASIC SWITCHES CAN STOP MACHINES FROM GOING BOOM. A Honeywell White Paper

WCD-1. Evaporative Cooling Modules. WCD Series. Alton. Keeps You. Cool

THE COMPLETE GUIDE TO OUTDOOR WALL LIGHTS

SCFM REFRIGERATED COMPRESSED AIR DRYERS. CRN Series

NON-CYCLING REFRIGERATED AIR DRYERS. RNC Series

POWER TOWER SERIES Fiberglass Construction 45 to 540 Tons

RNC Series SCFM Global Air Treatment

V-MUL-033(A0) RADIOLINK BASE

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

Gas-Fired Unit Heaters Commercial & Industrial

Packed With Features. Smart Pulsar controls are conveniently

PROFESSIONAL TOOL STORAGE SYSTEMS

Port-A-Cool unit. Pneumatic Owner s Manual. series manufactured by port-a-cool, llc FOR PNEUMATIC MODELS PAC2K36AD, PAC2K24AD, PAC2K16AD

Packed With Features ACCESSIBLE. Filter cartridge is automatically cleaned each time the pedal is operated.

Assembly and Instruction Manual. #CR-2550 shown below

Using Portable Spot Air Conditioners in Industrial Applications

ON-LOAD CLEANING FOR HEAT EXCHANGER FOULING. Optimising heat transfer on petrochemical plants and oil refineries

RNC Series SCFM Global Air Treatment

NEOSYS. AIR TO WATER LIQUID CHILLER kw. AIR TO WATER HEAT PUMP kw. lennoxemea.com

Bellows. Forest City Industrial Sewing is ideally suited to. Forest City Industrial Sewing specializes in fabricating

Flexible Heaters. of Silicone Rubber & Kapton

EZ Plate Instantaneous

CLE SERIES Fluid heating for emergency eyewash stations

MC CHANGER CABINET INSTALLATION INSTRUCTIONS

WATER I WHALE. Making every drop count! KAISER WHALE KAISER WHALE SPECIFICATION THE KING OF RECYCLERS FEATURES AND OPTIONS.

Heating Systems. Brooders, Space Heaters and QuadRadiant Heaters

Your Global Automation Partner. Minimizing Arc Flash Exposure in Industrial Applications. White Paper - W1000

BEVERAGE COOLER WITH DUAL TEMPERATURE ZONES INSTRUCTION MANUAL

Rail vehicles without compressed air? Practically inconceivable!

OPERATING INSTRUCTIONS

Greater temperature control

OPENING AN ENCLOSURE and blowing a fan on heat sensitive components

SECTION P01 LIGHTING AND APPLIANCE PANELBOARDS - A-SERIES

WINE COOLER. Model: WR 64-16

International PCT Patent Application No. PCT/GB2011/ Automag. Self-purging, fully automated magnetic filter

Differences Among Screw Plug Immersion Heaters

HARVESTING RAINWATER IS SPECIALIZED, LUCRATIVE

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

Manual is for the following models: G-26 GCG-26 GCG-26-C31N* G-26-C31N* GCG-26-C231N* GCG-26-CA31N* *G,I,M,7,J plug. Instruction Manual.

CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH

How about Savings in Time, Money, Energy and Longer Life?

C1D1 Explosion Proof Horn - Industrial Siren - Programmable Timer - NEMA 4X - Weatherproof

Chromalox. Installation, Operation. Portable Industrial Unit Blower Air Heater Types SDRA and SDRA-RG RENEWAL PARTS IDENTIFICATION

Based in the UK, Triogen is a world leading company with over twenty years experience in the design and manufacture of specialist Ozone and UV

3kW 6kW, QUBE Fiber Lasers

Agent Dissemination Devices

Cleaning Kit Instructions - DTC550 Printer

SECTION INTERIOR LIGHTING

154BC SPECIFICATIONS. Please refer to the 154N uncompensated and constant voltage datasheets for more information on different features of the 154.

Silicone Rubber Heaters FLEXIBLE HEATERS

Industrial Dust Aspiration Solutions. For optimal protection of plant and environment.

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

NewlyDesignedfor MaximumPerformance

Automating functions. Simplifying operations. Modernizing protection. Bebco EPS 5500 Automation for Purge and Pressurization

PROCESS AUTOMATION PEPPERL+FUCHS BEBCO EPS 6000 SERIES PURGE AND PRESSURIZATION SYSTEM

GENERAL AREAS OF INSPECTION

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2018

CHECKFIRE 210 Detection and Actuation System

SIMPLEX WEATHERPROOF CONTROL PANELS

KOOLTRONIC ENCLOSURE AIR CONDITIONER QUICK SHEET

Owners Manual Refrigerated Air Dryer MHT SERIES

CLI Refrigerant Gas Leak Detector. User s Guide

Lead-Lined Cabinetry. All Cabinets Feature: Pre-Configured Cabinet Models. Specialized Cabinet Models

AlarmLine Addressable Linear Heat Detector

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

COLD WEATHER SOLUTIONS: ELECTRIC HEAT AND CONTROL PRODUCTS

Tyco Electronics Solar Identification Labels

Humidity Measurement Technology pros & cons. Helping you make a better measurement.

154BC SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES

TEXAS DEPARTMENT OF TRANSPORTATION GENERAL SERVICES DIVISION LIGHT, WARNING, 360 DEGREE LED BEACON PUBLICATION

THE FUTURE OF FIRE SUPPRESSION

UltraDry s Features and Benefits

Industrial Horn & LED Strobe Warning System - 12V DC - Weatherproof - NEMA 4X - Class 1 Beacon

Bourns Thick Film Resistive Heaters

Cold Energy Saver. Thermal Mass Cycling Refrigerated Air Dryers ( scfm)

SP METHOD 5320 Issue No: Test method for fire detection systems installed in engine compartments of heavy vehicles

REI-M-4B - Installation Manual Rev 1 October SOLID BOSS Installation Manual Deck Drainage Applications

Home Performance Science

Auxiliary Fan Controller. Installation Instructions for Mazdaspeed 3

Operation and Maintenance Manual GLACIER TALL BASE CS5-16-VD-TB CS5-18-VD-TB2 120V/60HZ

Operator s Manual SAVE THESE INSTRUCTIONS. Light Weight Upright Vacuum. Model PF60EC, PF60VC, PF61EC and PF61VC

Transportation Applications

DURABLE LIGHTING PROVEN FOR PORTS

Automag. Self-purging, fully automated magnetic filter

Proximity Detection Systems. Reliable, proven solutions for mining safety

BASCO TYPE T and TC MOISTURE SEPARATORS and TRAP. ...world leaders in heat transfer technology

Transcription:

ID Technology Using Label Printer Applicators in Harsh Operating Environments Bruce Richards, Technical Sales Coordinator

Most Label Printer Applicators are used in moderate environmental conditions. But sometimes the ideal operating environment, a clean warehouse, ambient temperatures in the 60 to 70 degree range, air filters keeping the air free of debris, and no water spray, is not available. In these cases labeling equipment must adapt to the environment where it is needed to accomplish the required product identification. Innovations in labeling equipment design allow label printer applicators to be installed in harsh environments with great results. Cold Temperatures: The OEM Print Engines used in label printer applicators have a recommended operating temperature range. Anything above or below that can affect the operations of the engine and the ability to properly print information onto a label. The engines are fairly consistent in effective temperature ranges. Print Engine Heaters If you are operating in an environment where the ambient temperature is in the lower 30 degree range, then a simple print engine heater may be the solution. The print engine heater mounts to the door of the engine (Avery excluded). The door window is removed and the heater is installed in its place. The heater blows warm air into the print engine and raises the internal operating temperature of the engine into the required range.

Cold Temperature Enclosures Once you are below 30 degrees, a print engine heater will not suffice. A Cold Environment Enclosure would be the next step. There are different types that can be used, depending on the exact environmental conditions. If your operating temperature is in the mid 20 degree range, a simple Lexan enclosure with an industrial light bulb will bring the engine into the required operating temperature range. The Printer Applicator is encased in the Lexan box with an opening (removable or hinged) through which the application module extends and retracts. A high wattage light bulb mounted in the enclosure radiates enough heat to warm the inside of the enclosure. For the low 20 degree temperatures, a bulb and a door heater work well. Once you get below the 20 degree mark you will need to move up to an industrial heater. An electric heater that blows hot air is mounted in the enclosure to raise the ambient temperature of the enclosure the 20 or so degrees needed, and then keeps the temperature constant. At this point it is beneficial to upgrade to a stainless steel enclosure. The stainless steel enclosure provides a higher degree of protection, is more durable, and can support a heater while limiting the number of openings exposed to the cold environment. These enclosures can be used in reels up or reels out applicator orientation.

Dusty/Acidic Environments: In a dusty or corrosive environment, whatever particles are floating in the environment are going to get inside the print engine, onto the label stock and into the vacuum ports of a tamp pad. The amount and kind of dust in the air will dictate the best method of prevention. A light concentration can be countered with a Positive Air Kit mounted just inside the print engine. This redirects part of the plant air into the print engine compartment that holds the ribbon and print head. The air being routed into the compartment forces air to circulate within the compartment while forcing air out of the openings in the print engine. Light dust is prevented from entering the print engine compartment extending the life of the print head and components. When the dust gets heavier, it requires a larger enclosure with a positive air kit installed. The entire enclosure is pressurized to prevent particles from entering the machinery. Lexan enclosures allow the operator to easily view the printer applicator.

Wash Down Environment: Many plants go through a cleaning process at the end of each day. Equipment must be able to withstand the wet environment and function properly day in and day out. The degree of protection required is dependent on the force of the water spray. For equipment that only receives a light spray, a Lexan cover may suffice. For more intense wash down environments, stainless steel enclosures are designed to protect the machinery with minimal shutdown requirements. All cabling is run through a stuffing tube. The cabinet doors shut and seal against direct spray and a door can be placed over the application module opening. A wet and cold environment may also require a heating unit. Whatever the environment, there is a labeling solution to fit your product identification needs. About ID Technology ID Technology, a division of Pro Mach, designs, manufactures, and integrates custom identification systems and is recognized as a leading single-source provider for labeling, coding and marking equipment, expertise, service, and supplies. ID Technology is based in Fort Worth, Texas, and operates 16 regional offices across the United States. For more information or to locate one of the ID Technology nationwide sales and service centers, call 888.438.3242 or visit www.idtechnology.com.