Property Description: (1) level condominium in a multi-story building Property age/ size: Built 2006, 1,137 s.f. per listing Occupancy Status: Vacant

Similar documents
1710 ANYWHERE DRIVE, MONTGOMERY, AL 36109

Canadian Property Inspections

Inspection Report. 1 Inspection Way Orlando, FL Prepared for: Wanda Figueroa Prepared by: ACF Home Inspections Inc

I. STRUCTURAL SYSTEMS

The Home Inspector Alaska LLC Donna Ranson Certified Inspector Cell:

Inside Out Home Inspections

Home Inspection Report

RENTAL PROPERTY INVENTORY AND CONDITION FORM

Inspection Report 123 My Street Midland, GA

2016 CALIFORNIA CODES KITCHEN, BATH & LAUNDRY REMODEL REQUIREMENTS

Watson Home Inspection Services, LLC.

The Salvation Army Southern Territory OFFICERS QUARTERS PROPERTY INSPECTION FORM

Jeff Brown Inspections

Axiom Property Inspections

FAIRA TRANSPARENCY REPORTS NE 117th Pl, #F8, Kirkland, WA 98034

FAIRA TRANSPARENCY REPORTS Greenwood Ave N, N304, Seattle, WA March 21, 2018

FAIRA TRANSPARENCY REPORTS Country Club Dr, B-203, Mill Creek, WA April 5 th, 2017

FAIRA TRANSPARENCY REPORTS th Ave NE B-3, Kenmore, WA March 28 th, 2017

PROPERTY MANAGER S INVENTORY AND CONDITION REPORT

RW West Consultants. Property Inspection Report NE 199th St, Kenmore, WA Inspection prepared for: FAIRA/ Chris Ellis Real Estate Agent: -

Inspection Report. Prepared for: Tonia Mann. Property Address: 402 Leslie Court McDonough, GA Date: March 07, 2013

FAIRA TRANSPARENCY REPORTS S 236th St, 10-5, Kent, WA 98032

Inspecta-Homes 2469 University Avenue West St. Paul MN Ph#: (651)

FAIRA TRANSPARENCY REPORTS. November 21, 2016

Bay Wide Commercial and Home Inspection Thackeray Avenue/ Mail address Hayward, Calif TH AVENUE SAN LEANDRO, CALIFORNIA

FAIRA TRANSPARENCY REPORTS W Manor Pl, #413, Seattle, WA August 25, 2017

FAIRA TRANSPARENCY REPORTS Alaskan Way, 514, Seattle, WA 98101

Inspection Report. Mr. Happy Homeowner. Property Address: Focal Point Home Inspection Ltd.

General Kitchen, Bath & Bedroom Remodeling Notes County of Marin, Building Inspection Division

Patriot Home Inspections

FAIRA TRANSPARENCY REPORTS Hazel Loop SE, #D, Auburn, WA 98092

Home Inspection Report

RW West Consultants. Property Inspection Report

Maintence/Renewal Report

Extra Mile Inspection, Inc.

FAIRA TRANSPARENCY REPORTS NE 182nd St, C101, Kenmore, WA 98028

SUMMARY 1234 Main St.Severn Buyer Name 07/18/2018 9:00AM

Excellent Home Inspection Services, LLC

Steve Ramsey Home Inspections

TEXAS ASSOCIATION OF REALTORS RESIDENTIAL LEASE INVENTORY AND CONDITION FORM

FAIRA TRANSPARENCY REPORTS nd Ave S, E-2, SeaTac, WA 98198

Troy's Home Inspection Services LLC

1921 River Birch Dr., Shawnee, OK Inspection prepared for: Vicki Jager Date of Inspection: 7/27/2015 Time: 8am Weather: Sunny

Inspection Report. Prepared For: Joe Smith. Property Address: 1234 Slick Lane. #2 Chicago, IL. Inspectrum Inc.

MHI Services Inc. Property Inspection Report

FAIRA TRANSPARENCY REPORTS th Ave S, A304, Des Moines, WA March 13, 2018

Terry Building Inspection report summary with all items addressed or explained in red

Asurity 1. Property Inspection Report S Gurd Rd., Hastings, MI Inspection prepared for: Beretta Lenos Real Estate Agent: Stan Labinski -

FAIRA TRANSPARENCY REPORTS S 248th Pl, Des Moines, WA March 12, 2018

Inspector Gadget Homes

FAIRA TRANSPARENCY REPORTS S 284th Ln, #H204, Federal Way, WA March 12, 2018

RPP Inspection Documents

LUXURY HOME BED 3 BATH

Bayshore House Inspections LLC

FAIRA TRANSPARENCY REPORTS Waverly Dr, Snohomish, WA May 10 th, 2017

FAIRA TRANSPARENCY REPORTS Fairview Ave E, #304, Seattle, WA June 7 th, 2017

THE CROWN SERIES. Coco, Jackson & Myrtle Floorplans REV *With Craftsman Package

This Report Was Prepared For: Property Address Inspected:

Inspector FX Field Forms

About This Model. Series: Pennwest 2-Story Modular Model: HS125A Millington. Style: 2-Story / Bedrooms: 4 / Bathrooms: 3 / Square Feet: 2406.

(TAR-2006) Tenants:,,, & Landlord or Landlord's Representative:,

All Around Home Inspections Ltd 1346 Hurford Ave Courtenay, BC. 123 Sample 6 Plex

Plan 1. Single Story. zz Single-Story. zz 2 Bedrooms. zz Den. zz 2 Baths. zz 2-Car Garage. zz Optional Bedroom 3. zz 1,518 Square Feet

FAIRA TRANSPARENCY REPORTS Bothell Everett Hwy, D304, Bothell, WA February 6, 2018

Space Coast Home Inspections LLC

SAMPLE. (TAR-2006) Tenants:,,, & Landlord or Landlord's Representative:,

FAIRA TRANSPARENCY REPORTS S 272nd St, #39, Kent, WA September 1 st, 2017

FAIRA TRANSPARENCY REPORTS. 76 Cedar ST, Unit 505, Seattle, WA May 27, 2016

Habitability Guidelines

PREPARED FOR: (Name of Client) CONCERNING: (Address of Property) BY: P Home. YOUR HOME CHECK 1305 FM 359, Suite G F


FAIRA TRANSPARENCY REPORTS SE 41st Ln, E203, Bellevue, WA April 7 th, 2017

Closing Checklist. Mstr Hall/Clo. Mstr Bath. Guest Bath 1/2 Bath Kitchen Nook. Guest Hall. Utility Rm Garage Yard. Right Side Left Side Rear

Final Phase Inspection

FAIRA TRANSPARENCY REPORTS Spruce Way, Lynnwood, WA August 21, 2017

Coast Home Inspection

Cascade Inspection Services, LLC

HOME INSPECTION REPORT

FAIRA TRANSPARENCY REPORTS S 237th St, Kent, WA November 28, 2017

THANK YOU for your cooperation in cleaning this property we hope you have enjoyed living here.

TEXAS ASSOCIATION OF REALTORS

FAIRA TRANSPARENCY REPORTS th Ave, Seattle, WA April 28 th, 2017

Building and Safety Division Civic Center Dr, Bellflower, CA, (562) x

PROPERTY REINSPECTION REPORT

FAIRA TRANSPARENCY REPORTS Brighton Pl, Mukilteo, WA 98275

FAIRA TRANSPARENCY REPORTS st Pl SE, Sammamish, WA May 18 th, 2017

Newberry. Foundation Framing

FAIRA TRANSPARENCY REPORTS th Ave SE, Bothell, WA 98012

FAIRA TRANSPARENCY REPORTS th St SE, #13A, Auburn, WA January 25, 2018

Coquille Indian Housing Authority Maintenance Report February 2017

FAIRA TRANSPARENCY REPORTS. 405 SW 346th Pl, Federal Way, WA Nov 09th, 2015

The following report was prepared for the buyers of the home and property at 1400 Main St. Anywhere City, Tennessee. The inspection was conducted on

FAIRA TRANSPARENCY REPORTS th St SW, Lynnwood, WA 98037

FAIRA TRANSPARENCY REPORTS th Dr NE, Marysville, WA June 14 th, 2017

FAIRA TRANSPARENCY REPORTS. January 27 th, 2017

Examples of Acclaim s Energy-Efficiency Green Technology

National Property Inspections

About This Model. Series: Pennwest 2-Story Modular Model: HA402A Pennwest Ultra 5. Style: 2-Story / Bedrooms: 3 / Bathrooms: 3 / Square Feet: 2579

Paramount Property Mgmt & Realty LLC MOVE-IN / MOVE-OUT CONDITION CHECKLIST

An Owner s Guide to Maintaining a Mobile / Manufactured Home August 2010

Transcription:

(425) 652-6515 Kevin@Hergert.com Wa. Home Inspector 619 WSDA Inspector 79988 WSDA Control # 1336AQ-012 Client: Address: Property Description: (1) level condominium in a multi-story building Property age/ size: Built 2006, 1,137 s.f. per listing Occupancy Status: Vacant Inspection Date: 12/10/2011 Inspection Time: 9:00 A.M. 11:00 A.M. Weather Conditions: Overcast, 40 deg F +- Hergert Inspection LLC Kevin Hergert, Member Page 1 of 18

Table of Contents Summary of Inspection...3 Electrical System...4 Water Heater...5 Living Room and Dining Room...7 Kitchen...10 Hallways...11 Bedroom # 2...12 Main Bathroom...14 Master Bedroom Suite...15 Garage...17 Structural Pest Inspection Diagram...18 Page 2 of 18

Summary of Inspection All items listed in the Summary of each section are listed below. Additional comments may be written in the body of the report. Please read the entire report. All items listed below should be further evaluated, inspected, modified, and/or corrected by a licensed professional in that corresponding or related trade. WDO refers to Wood Destroying Organism as defined by the Washington State Department of Agriculture - Items in this font are general comments throughout report. - Items in this font are considered a minor cost and/or cosmetic. - Items in this font are considered a substantial cost an extreme safety concern. Electrical System Water Heater Living Room and Dining Room - Hardwood flooring does not lay flat at various areas of the Living room. Sharp edges of the boards are not flush to the adjacent boards - Window opening limiter has been removed from (1) window. Fall hazard as window sill are approximately 12 above the floor - Substantial air leakage at door to deck. Recommend replacement of weather-stripping and/or adjustment of the door Kitchen - Recommend removal of the light switch the controls the electrical outlet for microwave hood vent Hallways - Error code HF at washing machine. The error code "HF" refers to a problem with the amount of water entering the washing machine. Unable to access water shut of valve. This may be the result of the valves in the off position or a defect in the washing machine - Deck barricade is a ladder style railing. This style of barricade is a potential fall hazard. Recommend cover barricade if small children are present. Bedroom # 2 - Recommend install limiter on South window as this window conflicts with the exterior deck door Main Bathroom Master Bedroom Suite - False drawer pulls are loose at both sinks - Outlet at corner of room near heater is inoperative - Switched outlet near bathroom does not fully turn off - Unknown purpose of 3 rd wall switch (possible paddle fan pre-wire) - Window opening limiters have been removed. Fall hazard as window sill are approximately 12 above the floor Garage - Recommend replacement of exterior key pad and emergency key access for the garage door opener disconnect (for security from prior owner) Page 3 of 18

Electrical System No evidence of over heating Service Type: Underground Meter Location: - No access to electrical room Voltage: 240 Sub Panel Location: Manufacturer: Type: Main Disconnect: Serv. wire Size/ Rating: Panel Clearance: Breakers/ Wiring Type: Breakers: Bedroom Square D Dual bus bar n/a 100-125 AMP 30 wide, 3 in front as required Copper romex - Arc fault breakers tested Page 4 of 18

Water Heater Water Heater Location: Make/ Model: Fuel Type: Capacity: Utility closet AO smith s/n J06E000093 Electric 40 gallon Useful Life Est. Useful Life new: 12 years Est. age of heater: 6 years +- Heat from upper heating element Hear from lower heating element Page 5 of 18

Safety TMP valve: Earthquake Straps: Safe water temperature: Measured temperature: As per required Installed 120 deg F per industry standards 113 deg F Water temperature @ kitchen Domestic Water Shut off: - Utility closet. This valve will not shut off the fire control system Domestic water shut off Page 6 of 18

Living Room and Dining Room Location: Floor 3 General Room Condition Visibility: Room is vacant Structural Movement: No visible evidence Moisture Infiltration: No visible evidence Walls: Ceiling: Flooring: - Hardwood flooring does not lay flat at various areas of the Living room. Sharp edges of the boards are not flush to the adjacent boards Edges of laminate hardwood are not flush Electrical Switches/Lights: Outlets: Heating Source: Air Flow/ Heat Gain: All visible tested All visible tested Electric wall register Windows Glazing: Tempered: Operation: Screen: Not required - Window opening limiter has been removed from (1) window. Fall hazard as window sill are approximately 12 above the floor Page 7 of 18

North window has limiter installed All others have been removed Doors/Millwork Operation/latching: Door condition: Millwork condition: - Substantial air leakage at door to deck. Recommend replacement of weather-stripping and/or adjustment of the door Air leakage at the door to the deck Page 8 of 18

Fireplace Type: : Sealed gas direct vent Ignition tested - Install D batteries at fireplace for ignition of the fireplace during a power outage Battery compartment in lower compartment of fireplace (2) D batteries Page 9 of 18

Kitchen Location: Floor 3 General Room Condition Visibility: Room is vacant Structural Movement: No visible evidence Moisture Infiltration: No visible evidence Walls: Ceiling: Flooring: Cabinets: Countertops: Appliances Dishwasher: Dishwasher air gap: Oven: Cooktop: Microwave: Ventilation: Refrigerator: Plumbing Functional flow: Hot/ Cold: Drainage: Visible leaks: Disposal: Caulking: Fixtures: Electrical Switches/Lights: Outlets: Heating Source: Air Flow/ Heat Gain: Doors/Millwork Operation/latching: Door condition: Millwork condition: full cycle Visible Not tested Appears adequate Appears adequate None visible All visible tested - Recommend removal of the light switch the controls the electrical outlet for microwave hood vent All visible tested, GFCI protected Adjacent room Page 10 of 18

Hallways Location: Floor 3 General Room Condition Visibility: Space is vacant Structural Movement: No visible evidence Moisture Infiltration: No visible evidence Walls: Ceiling: Flooring: Electrical Switches/Lights: Utility Outlets: Smoke Detector: Washer: Dryer: Mechanical ventilation:: Doors/Millwork Operation/latching: Door condition: Millwork condition: All visible tested - Light bulb in closet appears to be burnt out All visible tested Yes - Error code HF at washing machine. The error code "HF" refers to a problem with the amount of water entering the washing machine. Unable to access water shut of valve. This may be the result of the valves in the off position or a defect in the washing machine -, vented to exterior Deck Barricades: - Deck barricade is a ladder style railing. This style of barricade is a potential fall hazard. Recommend cover barricade if small children are present. Ladder style barricade Page 11 of 18

Bedroom # 2 Location: Floor 3 General Room Condition Visibility: Room is vacant Structural Movement: No visible evidence Moisture Infiltration: No visible evidence Walls: Ceiling: Flooring: Electrical Switches/Lights: Outlets: Smoke Detector: Heating Source: Air Flow/ Heat Gain: All visible tested All visible tested Electric baseboard - If heating system is moved, recommend that this work be completed by a licensed electrician Electrical wires to thermostat Electrical wires to thermostat Page 12 of 18

Windows Glazing: Tempered: Operation: Egress: Screen: Maintain proper clearances to combustibles Not required - Recommend install limiter on South window as this window conflicts with the exterior deck door Appears to meet current egress standards Window conflicts with deck door Doors/Millwork Operation/latching: Door condition: Millwork condition: Page 13 of 18

Main Bathroom Location: Floor 3 General Room Condition Visibility: Room is vacant Structural Movement: No visible evidence Moisture Infiltration: No visible evidence Walls: Ceiling: Flooring: Cabinets: Countertops: Mirrors: Electrical Switches/Lights: Outlets: Heating Source: Air Flow/ Heat Gain: Mechanical ventilation: Doors/Millwork Operation/latching: Door condition: Millwork condition: Bath Hardware: Plumbing Functional flow: Hot/ Cold: Drainage: Visible leaks: Caulking: Toilet Secure: Tub/Shower surround: Fixtures: All visible tested All visible tested, GFCI protected Heat lamp Appears adequate Appears adequate None visible Page 14 of 18

Master Bedroom Suite Location: Floor 3 General Room Condition Visibility: Room is vacant Structural Movement: No visible evidence Moisture Infiltration: No visible evidence Walls: Ceiling: Flooring: Cabinets: - False drawer pulls are loose at both sinks Countertops: Mirrors: Electrical Switches/Lights: Outlets: Smoke detector: Heating Source: Air Flow/ Heat Gain: Mechanical ventilation: All visible tested All visible tested. Bathroom outlets are GFCI protected - Outlet at corner of room near heater is inoperative - Switched outlet near bathroom does not fully turn off - Unknown purpose of 3 rd wall switch (possible paddle fan pre-wire) Yes Electric baseboard and heat lamp Maintain proper clearances to combustibles Page 15 of 18

Windows Glazing: Tempered: Operation: Screen: As required - Window opening limiters have been removed. Fall hazard as window sill are approximately 12 above the floor Casement windows can fully open Condominium is on the 3 rd floor Doors/Millwork Operation/latching: Door condition: Millwork condition: Bath Hardware: Plumbing Functional flow: Hot/ Cold: Drainage: Visible leaks: Caulking: Toilet Secure: Tub/Shower surround: Fixtures: Appears adequate Appears adequate None visible Page 16 of 18

Garage Type: Detached General Room Condition Visibility: Structural Movement: Moisture Infiltration: Walls: Ceiling: Slab: Safety Ignition point > above FF: Garage Door Type: Springs & Fasteners: Auto Reverse: Photocell reverse: Remote openers: Space is vacant No visible evidence No visible evidence In compliance Metal roll-up Not present - Recommend replacement of exterior key pad and emergency key access for the garage door opener disconnect (for security from prior owner) Electrical Switches/Lights: Outlets: All visible tested, GFCI protected Page 17 of 18

Structural Pest Inspection Diagram Wood Destroying Organisms (WDO) Conducive Conditions (CC) WDO-AB Anobid Beetles CC-BG Bare Ground WDO-CA Carpenter Ants CC-CD Conducive Debris WDO-DT Dampwood Termites CC-EM Excessive Moisture WDO-MA Moisture Ants CC-EW Earth-Wood Contact WDO-OB Other Beetles CC-FC Failed Caulking WDO-RF Rot Fungus CC-IV Inadequate Ventilation WDO-ST Subterranean Termites CC-RG Restricted Gutter CC-VC Vegetation Contact Inspection Conditions (IC) IC-CSA Crawl Space Access IC-IA Inadequate Clearance No structural pests or conducive conditions identified Page 18 of 18