GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

Similar documents
AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

Air cooled water chillers

Air cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw

Water cooled chillers and heat pumps

ERAH MC Ka. Range kw. AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS FOR OUTDOOR INSTALLATION (Standard line)

Air cooled chillers. Air cooled chillers with screw compressors and axial fans

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

AIR COOLED LIQUID CHILLERS FOR OUTDOOR INSTALLATION

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

LZT High efficiency air to water heat pumps with E.V.I. compressors

LZA High efficiency air to water heat pumps with HP compressor

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

Water cooled chillers and heat pumps

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

NEXT EVO DXR410A NEXT EVO DX NEW SOFTWARE. rcgroupairconditioning

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

ED.X F Kc DIRECT EXPANSION CLOSE CONTROL UNITS WITH REMOTE CONDENSERS AND ADDITIONAL CHILLED WATER FREE COOLING COIL

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

Air Cooled Chillers & Heat Pumps WinPACK HE-A

pyxis hp "u" pyxis hp "u" IDEA NEW rcgroupairconditioning

WSK WSK. Water to water chillers and heat pumps VERSIONS ACCESSORIES

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

Multi-pipe Units with Scroll Compressors. Model CMAA Cooling capacity kw Heating capacity kw

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

pyxis u pyxis ua NEW rcgroupairconditioning

unico pf unico pf rcgroupairconditioning

PYXIS U PYXIS U. rcgroupairconditioning

kw COOLING kw HEATING

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

Motor-driven condensing units MTE MTE R-410A

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

Galletti Water chillers and heat pumps catalogue

pyxis pyxisa NEW rcgroupairconditioning

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

LER kw. Indoor motor-driven evaporating units. Motor-driven evaporating units LER PLUS

Packaged air cooled liquid chillers for outdoor installation kw. technicalcatalogue T_EGL_1012_GB

LZT LZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSION ACCESSORIES

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

WZH Ground source heat pumps

pyxis cla pyxis cla A-CLASS NEW rcgroupairconditioning

WDH WDH. Ground source heat pumps OTHER VERSIONS ACCESSORIES

HYDRONIC RESIDENTIAL

glider evo cla glider evo cla A-CLASS rcgroupairconditioning

GLIDER EVO FREE GLIDER EVO FREE GLYCOL FREECOOLING. rcgroupairconditioning

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

GLIDER EVO GLIDER EVO. rcgroupairconditioning

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

PRODUCT GUIDE

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

LZT High efficiency air to water heat pumps with E.V.I. compressors

GLIDER EVO CLA GLIDER EVO CLA HIGHEFFICIENCY ACLASS. rcgroupairconditioning

Superchiller Product Documentation. English. cod rev Issued by TDS

HIWARM kw. Air-water system with external and internal BLDC unit. Total heat recovery multi-purpose units HIWARM PLUS

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

WZT High Efficiency Air to Water Split System Heat Pumps With E.V.I. Compressors

NEMO A Split-system liquid chillers for indoor installation. Cooling Capacity: 5 26 kw

nemo a hp rcgroupairconditioning R410A

44,9 202,0 kw. technicalcatalogue

EQSL TECHNICAL CATALOGUE AIR COOLED WATER CHILLER UNITS AXIAL FANS. Models: 300 V2 F V2 F16. Cooling capacity: 299 to 1310 KW

york airside products Tailored air conditioning solutions Introducing the YORK YPRE range of custom air-to-air packaged roof top units

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

MAC N-407 Air-Cooled Chiller

TECHNICAL MANUAL FOR AIR-COOLED CONDENSING UNITS MTE

WHA WHA. Ground source heat pumps OTHER VERSIONS ACCESSORIES

CHAPTER 6 CONDENSING UNITS

WHA WHA. Ground source water to water heat pumps A ++ A ++ Versions

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

21,8 222 kw COOLING 25,2 236 kw HEATING

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

Aquaflair. Residential and Industrial Cooling Systems

MPE 4-76 kw. Outdoor monobloc unit. Air chillers and heat pumps MPE PLUS. Efficiency under all operating conditions. 152 galletti.

BETA ECHOS. Air/water cooled chillers and heat pumps kw. General BETA ECHOS is a range of chillers and ductable air-water heat pumps.

GLIDER_. air cooled liquid chilled chillers / heat pumps

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating.

NEXT DL NEXT DL. rcgroupairconditioning

EQUH PF PACKAGED HEAT PUMP AIR/ WATER LIQUID CHILLER FOR INDOOR INSTALLATION

EQEF TECHNICAL CATALOGUE AIR COOLED WATER CHILLERS AXIAL FANS WITH FREE-COOLING SYSTEM

Transcription:

UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS GPE 802 Kc + CF + GP + MV + P1 130 Above picture is only indicative and is not binding. AIR R-410A The units of GPE.Kc series can be installed in all the applications where there is the need to produce at the same time cold and warm water. The peculiarity of this Polyvalent Groups is to suit all the needs of the system, independently from weather conditions. These units are 4-pipes heat pumps with separate and not interchangeable circuits, supplied with an additional water/refrigerant condenser/recovery on each cooling circuit, able to entirely replace the air/ refrigerant condensing coil and to produce free warm water, when needed. OPERATION MODES MODE 1: Only Cooling Mode When warm water production is not required, the unit runs as a water chiller and only produces chilled water. With such a running mode and in order to complete the cooling process, the exchangers in use are the evaporator and the finned air cooled condensing coil. MODE 2: Cooling Mode with heat recovery When warm water is required as well, the unit can operate as water chiller with heat recovery and produce warm water at the same time, without additional costs and exploiting the heating power of the condensing process. In this way, in order to complete the cooling process, the evaporator and the water cooled condenser/recovery, where the condensing process takes place, are the exchangers in use. MODE 3: Heat Pump Mode The unit runs as an heat pump and therefore produces warm water. With such a running mode and in order to complete the cooling process, the finned condensing coil (as evaporator) and the water cooled condenser/recovery, where the condensing process takes place, are the exchangers in use. Being 2-circuit unit, it is possible to have all the above mentioned running modes at the same time on different circuits (i.e. the circuit 1 can be on Mode 1 and the circuit 2 can be on Mode 2 or 3). Operation limits (standard units): SUMMER OPERATION: Air from 15 to 45 C - water (out from evaporator) from 5 to 15 C. WINTER OPERATION: Air from 20 to -4 C - water (out from evaporator) max 50 C. MAIN COMPONENTS Structure made of a base and a chassis manufactured in high-thickness galvanised steel, assembled with stainless steel rivets. All galvanised steel surfaces are powder-coated with colour RAL 7035. When required, the hydraulic kit (buffer tank and pump group) are installed inside the unit.

High-efficiency scroll compressor (EER 3,7 at ARI conditions), with low sound level, internal heat protection, installed on rubber vibration dampers, supplied with crankcase heater, when necessary. Being 2 circuit units, in case of problem on one of the circuit, the 50% operation of the unit is anyway granted. Heat-exchange external coil with copper tube and specially corrugated aluminium fins for a better efficiency. It is suitably sized with a wide exchange surface, so to the allow the unit operation also at very high external air temperatures. On request, in case of installation in aggressive environments, several coil protection treatments are available. Dry expansion shell and tube evaporator with two refrigerant circuits, in carbon steel and copper tubes, insulated by close-cell polyurethane foam material. It is complete with electric heater and water flow switch. Shell and tube heat recovery / condenser in carbon steel and copper tubes. Low rpm axial fans, of directly coupled type, with 6-8 pole electrical motor complete with in-built overload protection, electronic balance, low sound level blades with wing profile and safety protection grid. The fans speed control is standard provided. Cooling circuit realized with copper or steel pipes, composed of thermostatic expansion valve, solenoid valves for automatic changeover of the different operation modes, dehydrating filter, sight glass, check valves on the liquid line, safety valves, shut off valves, high and low pressure switches and gauges. Electric board in compliance with CE norms, contained in a suitable partition protected by the internal safety panel, provided with a main switch and an external and hinged panel to be opened. It is complete with remote switches, overload protections, transformer for auxiliaries and terminal board. In case of hydraulic kit on board, the electrical control of the pump group is provided. MV P1 P1H PA PM RL RM RR VB Buffer tank of suitable capacity complete with expansion vessel, safety valve, water gauge, water charge and discharge valves, air purging valves. Single pump group: Chilled water pump group composed of single pump, expansion vessel, safety valve, water gauge, water charge and discharge valves, air purging valves, electrical control of the pump. The pump is of 2 pole centrifugal packaged type. Higher available pressure pump group: Chilled water pump group made of a single pump, expansion vessel, safety valve water gauge, water charge and discharge valves, air purging valves, electric control of the pump. The pump is of enbloc 2-pole type. Rubber-type vibration dampers: Bell-shaped vibration dampers supports for insulating the unit (supplied in kit), made of base and bell in galvanized steel and natural rubber mixture. Spring-type vibration dampers: Spring-type vibration dampers support, for insulating the unit (supplied in kit), mainly indicated for installation in difficult and aggressive environments. Made of two steel plates containing a suitable quantity of harmonic steel springs. Compressors overload relays: Electromechanical protection devices against compressor s overload with displayed alarm. Condensing coil with pre-painted fins: Epoxy coating of the condensing coils surface. Copper/copper condensing coils: Special execution of the condensing coils with copper pipe and fins. Brine version: Unit suitable for working with evaporator outlet water temperatures lower than 0 C. A 20 mm evaporator insulation will be provided. 131 Unit management microprocessor installed on the internal safety panel of the electrical board, complete with compressors hour counter. ACCESSORIES AE CFU CS GP IH MF Electrical power supply different from standard: Mainly, 230V three-phase, 460V three-phase. Frequency 50/60 Hz. Soundproofed compressors cabinet with higher thickness material: Compressor insulation with high-density sound and fireproofing materials of higher thickness. Compressors inrush counter: Electromechanical device positioned inside the electrical board, recording the total inrush starts of compressors. Condensing coil protection grid: Metal protection grid against accidental impacts. RS 485 serial interface: Electronic card to be connected to microprocessor, to allow communication between the units and a Carel supervision system. It is possible to fully control the unit remotely. For connection to other supervision systems, the protocol of the controlled parameters is available on request. Phase monitor: Electronic device controlling the correct sequence and/or the eventual lack of one of the 3 phases, switching off the unit if necessary.

MODE 1: Only Cooling Mode MODE 2: Cooling Mode with heat recovery 132 MODE 3: Heat Pump Mode

Technical data sheet - GPE 802-2302 Kc GPE 802 Kc 1002 Kc 1302 Kc 1502 Kc 1702 Kc 2002 Kc 2302 Kc Cooling capacity Cooling capacity kw 77,6 110,2 135,6 158,1 179,0 216,3 241,3 Absorbed power kw 27,1 34,5 42,3 47,3 51,2 72,3 85,2 EER Gross 2,86 3,19 3,20 3,34 3,50 2,99 2,83 EER NET 2,42 2,79 2,87 2,76 2,93 2,63 2,54 ESEER 3,59 3,55 3,77 3,77 3,71 3,87 3,98 Heating capacity Heating capacity kw 101,5 136,0 166,2 192,2 218,1 269,0 300,4 Absorbed power in heating kw 25,9 37,5 45,4 49,9 54,6 71,1 78,6 COP Gross 3,92 3,63 3,66 3,85 3,99 3,78 3,82 COP Net 3,29 3,20 3,30 3,21 3,38 3,32 3,39 Scroll compressors Quantity n 2 2 2 2 2 4 4 Standard steps capacity n 2 2 2 2 2 4 4 Circuits n 2 2 2 2 2 2 2 Nominal absorbed current A 44,4 57,0 68,8 77,5 84,6 118,8 131,0 Maximum absorbed current A 60,9 88,0 106,0 108,7 121,7 170,9 188,9 Inrush current A 170,7 239,7 245,7 321,4 325,4 294,4 300,4 Axial fans Quantity n 2 2 2 4 4 4 4 Rotation speed rpm 885 885 885 885 885 885 885 Motors power kw 4,96 4,96 4,96 9,92 9,92 9,92 9,92 Total air flow m³/h 55.400 55.180 53.150 110.800 110.800 108.800 104.200 Total air flow l/s 15.389 15.328 14.764 30.778 30.778 30.222 28.944 Nominal absorbed current A 10,3 10,3 10,3 20,6 20,6 20,6 20,6 Brazed plate evaporator Water flow rate m³/h 13,3 19,0 23,3 27,2 30,8 37,2 41,5 Water flow rate l/s 3,7 5,3 6,5 7,6 8,6 10,3 11,5 Pressure drop kpa 49 61 66 67 73 69 74 Brazed plate condenser Water flow rate m³/h 17,5 23,4 28,6 33,1 37,5 46,3 51,7 Water flow rate l/s 4,8 6,5 7,9 9,2 10,4 12,9 14,4 Pressure drop kpa 83 87 93 95 108 102 110 Pump group P1 Available pressure with P1 kpa 91 93 102 91 104 114 86 Motor power with P1 kw 1,5 1,9 3,0 3,0 4,0 4,0 4,0 Nominal absorbed current A 3,9 5,0 6,2 6,2 7,4 7,4 7,4 Hydraulic kit Buffer tank water volume l 100 300 300 300 300 300 300 Weight with empty MV included Kg 40 80 80 80 80 80 80 Electrical data Total absorbed power kw 32,1 39,5 47,3 57,2 61,1 82,2 95,1 Total nominal absorbed current A 54,7 67,3 79,1 98,1 105,2 139,4 151,6 Total maximum absorbed current A 71,2 98,3 116,3 129,3 142,3 191,5 209,5 Total inrush current A 181,0 250,0 256,0 342,0 346,0 315,0 321,0 Sound pressure level Sound pressure level 2) db(a) 75,2 75,2 77,4 78,2 78,1 78,5 78,9 Dimensions Length mm 2.980 2.980 2.980 5.780 5.780 5.780 5.780 Width mm 1.370 1.370 1.370 1.370 1.370 1.370 1.370 Height mm 2.420 2.420 2.420 2.420 2.420 2.420 2.420 Weight kg 1.230 1.265 1.310 1.895 1.980 1.915 2.030 Refrigerant charge kg 21 32 42 42 62 62 62 Power supply Power supply V / ph / Hz 400 V/ 50Hz / 3Ph + N + T NOTES Nominal conditions referred to: Summer work mode: air 35 C - chilled water 7/12 C. Winter work mode: air 10 C - warmed water 40/45 C. 2) Measured at 1 m in open field (ISO 3746). 133

134 Technical data sheet - GPE 2802-4102 Kc GPE 2802 Kc 3102 Kc 3202 Kc 3402 Kc 3602 Kc 3802 Kc 4102 Kc Cooling capacity Cooling capacity kw 268,4 314,2 344,9 368,2 386,7 407,0 426,0 Absorbed power kw 85,1 97,4 113,3 116,2 120,7 129,0 140,0 EER Gross 3,15 3,23 3,04 3,17 3,20 3,16 3,04 EER NET 2,83 2,93 2,74 2,86 2,91 2,88 2,80 ESEER 3,76 3,89 3,89 3,75 3,83 3,84 3,89 Heating capacity Heating capacity kw 335,7 381,5 420,1 443,5 473,1 496,7 515,2 Absorbed power in heating kw 85,2 96,4 107,2 113,4 119,6 125,2 126,0 COP Gross 3,94 3,96 3,92 3,91 3,96 3,97 4,09 COP Net 3,53 3,59 3,51 3,53 3,58 3,61 3,72 Scroll compressors Quantity n 4 4 4 4 4 4 4 Standard steps capacity n 4 4 4 4 4 4 4 Circuits n 2 2 2 2 2 2 2 Nominal absorbed current A 138,0 159,0 186,5 195,5 207,7 218,3 229,3 Maximum absorbed current A 212,0 238,0 258,9 284,0 304,0 314,0 324,0 Inrush current A 313,4 401,4 421,3 430,3 442,3 460,3 469,3 Axial fans Quantity n 4 4 5 5 5 5 5 Rotation speed rpm 885 885 885 885 885 885 885 Motors power kw 9,92 9,92 12,4 12,4 12,4 12,4 12,4 Total air flow m³/h 101.200 99.160 124.500 121.830 120.470 120.470 120.470 Total air flow l/s 28.111 27.544 34.583 33.842 33.464 33.464 33.464 Nominal absorbed current A 20,6 20,6 25,8 25,8 25,8 25,8 25,8 Brazed plate evaporator Water flow rate m³/h 46,2 54,0 59,3 63,3 66,5 70,0 73,3 Water flow rate l/s 12,8 15,0 16,5 17,6 18,5 19,4 20,4 Pressure drop kpa 56 73 68 72 70 72 70 Brazed plate condenser Water flow rate m³/h 57,7 65,6 72,3 76,3 81,4 85,4 88,6 Water flow rate l/s 16,0 18,2 20,1 21,2 22,6 23,7 24,6 Pressure drop kpa 97 104 98 101 97 100 70 Pump group P1 Available pressure with P1 kpa 89 107 98 115 109 106 110 Motor power with P1 kw 4,0 5,5 5,5 7,5 7,5 7,5 7,5 Nominal absorbed current A 7,4 11,0 11,0 14,0 14,0 14,0 14,0 Hydraulic kit Buffer tank water volume l 820 820 820 1100 1100 1100 1100 Weight with empty MV included Kg 145 145 145 220 220 220 220 Electrical data Total absorbed power kw 95,0 107,3 125,7 128,6 133,1 141,4 152,4 Total nominal absorbed current A 158,6 179,6 212,2 221,2 233,4 244,0 255,0 Total maximum absorbed current A 232,6 258,6 284,6 309,8 329,8 339,8 349,8 Total inrush current A 334,0 422,0 447,0 456,0 468,0 486,0 495,0 Sound pressure level Sound pressure level 2) db(a) 78,9 79,2 80,6 80,9 80,3 81,7 87,4 Dimensions Length mm 5.780 5.780 6.680 6.680 6.680 6.680 6.680 Width mm 1.370 1.370 1.370 1.370 1.370 1.370 1.370 Height mm 2.420 2.420 2.420 2.420 2.420 2.420 2.420 Weight kg 2.980 3.020 3.420 3.610 3.740 3.795 4.050 Refrigerant charge kg 62 80 80 80 96 96 96 Power supply Power supply V / ph / Hz 400 V/ 50Hz / 3Ph + N + T NOTES Nominal conditions referred to: Summer work mode: air 35 C - chilled water 7/12 C. Winter work mode: air 10 C - warmed water 40/45 C. 2) Measured at 1 m in open field (ISO 3746).