VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

Similar documents
VertiCool Aurora Engineering Guide

C13-Series Engineering Guide

CoolSpot Engineering Guide

VariCool VAV Engineering Guide

VERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons

Alpha Aire. Dedicated Outdoor Air System, VAV, Air-Source Heat Pump with Energy Recovery. Engineering Guide Effective February 2018

VariCool VAV. (Variable Air Volume) 9 to 70 tons Variable Air Volume Water-Cooled and Chilled Water. Unique Solutions for All-Indoor HVAC Projects

VertiCool Space Saver 2 to 15 Tons Water-Cooled and Chilled Water Air-Cooled w/remote Condenser

C-Series. Unique Solutions for All-Indoor HVAC Projects

CoolSpot. Unique Solutions for All-Indoor HVAC Projects

C13-Series. Unique Solutions for All-Indoor HVAC Projects

MiniCool Ductless Split A/C Systems 1 9 Tons Single or Multi-Compressor Circuits Air-Cooled, Water-Cooled, and Chilled Water

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

VariCool EZ-Fit 12 to 70 Tons Variable Air Volume Water-Cooled Water Source Heat Pump Chilled Water

Alpha Aire. Dedicated Outdoor Air System, VAV, Air-Source Heat Pump with Energy Recovery

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

HORIZONTAL SERIES. AIRPAC HORIZONTAL PACKAGED SERIES 24,000 to 180,000 BTU/h

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

technical guide Water-Cooled Self-Contained Units

Water-Cooled Self-Contained Units

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

VariCool EZ-Fit. Unique Solutions for All-Indoor HVAC Projects

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES - FIELD INSTALLED. K5EU090 and K4EU Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ)

ENGINEERING SPECIFICATIONS

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

ENGINEERING SPECIFICATIONS

Data Aire Mini Ceiling Systems 1, 1.5, 2, and 2.5 ton capacities R-410A. ISO 9001 Certified

Commercial High-Efficiency Condensing Units

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

Commercial High-Efficiency Condensing Units

SKYPAK II, 3 Ton Series, gives you a

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data

SKYPAK II, 3 Ton Series, gives you a

Technical Guide DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS. 7-1/2 and 10 NOMINAL TONS LA090 & LA120 SUPPLY AIR PLENUMS

Advance Release September 2009

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

Product Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving

Product Data. Features/Benefits. OMNIZONE 50BV Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL

Shelf Units R-407C. 2, 3, and 4 ton. ISO 9001 Certified

VERSECON Indoor Vertical Self-Contained Air Conditioner YSWU Ton Water-Cooled

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

-2x2. eair floor mounted precision air conditioners (MC22-L10) R407C & R410a Data. From 1 to 3 Tons. Engineering Manual

CATALOG. SKYPAK Self-Contained Heating/Cooling Units

TECHNICAL SPECIFICATIONS

TECHNICAL GUIDE DESCRIPTION EA090/FA090 SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNIT INDOOR UNIT

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

STULZ CyberAiR Floor Mounted Systems. Engineering Manual. Floor Mounted Air Conditioners

COMMERCIAL AIR HANDLER

Data Aire LCS TM (Large Ceiling System) R-407C. 6, 8, 10, and 13 ton. ISO 9001 Certified

Data Aire LCS TM (Large Ceiling System) R-410A. 6, 8, 10, and 13 ton. ISO 9001 Certified

MAC-120HE-03 Air-Cooled Chiller

Data Aire Mini Ceiling Systems 1, 1.5, 2, and 2.5 ton capacities R-410A. ISO 9001 Certified

SUBMITTAL DATA SHEET FEATURES. SPLIT-SYSTEM EVAPORATOR BLOWERS 7.5, 10, 15 & 20 TONS MODELS: NH-07 thru -20, 2-PIPE NJ-10 thru -20, 4-PIPE

CeilMate TM Series 3 and 4 tons of cooling capacity. Ceiling Mounted Systems. Air Handler with Remote Condensing Unit Air Handler designed for R-410A

SC SpotCool. 1 to 3 Tons. R407c & R410a. 2 x 4 Packaged & Split. Spot-Cooler & Ducted. eair above-the-ceiling air conditioners (ASC-L22)

MAC N-407 Air-Cooled Chiller

COMMERCIAL PACKAGED HEAT PUMP AIR HANDLER UNITS, 6 20 TONS

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

MACH N-407 Heat Pump Air-Cooled Chiller

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

VK 3-30 Tons. R407C Data. Vertical Comfort Cooling A/C s & Heat Pumps. 3 to 30 Tons. VK Veritical Cooling Comfort air conditioners (AVK-R7-L25)

COMMERCIAL AIR HANDLER

RT-OA TM Rooftop Outdoor-Air (DOAS)

ASHRAE 90.1 EFFICIENCY PACKAGE AIR CONDITIONER UNIT MBtuh

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

Call us today! (800)

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

GUIDE SPECIFICATIONS AQUARIUS ii

WALL-MOUNT HEAT PUMPS - (60HZ)

RHGN-H: COMMERCIAL AIR HANDLER WITH VARIABLE FREQUENCY DRIVE (VFD) NOMINAL 10 TONS R-410A REFRIGERANT 2-STAGE AIR-FLOW

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

Split System Heat Pumps

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

STULZ FLAiR Systems Floor Mounted Console Air Conditioners 5-17 kw / Single Circuit / DX Air / Water / Glycol. Engineering Manual

Air-Cooled Condensing Units with Compact Screw Compressors

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

JCseries EVAPORATIVE CONDENSER. engineering data

Transcription:

VertiCool CLASSIC Engineering Guide Effective March 2018 Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

Contents Product Features... 3 UNIT FEATURES... 3 OPTIONS:... 3 Physical Data... 4 5 Air-Cooled Performance Data (a) (b) (c)... 6 Water-Cooled Performance Data (a) (c) (d) (e)... 7 Water Source Heat Pump Performance Data (a) (c) (d) (e)... 8 Blower Performance Data... 9 Evaporator (a) (b)... 9 Condenser... 9 Steam Coil... 9 Hot Water Coil Performance (a) (b) (c) (d) (e) (f) (g)... 10 Chilled Water Coil Performance (a) (b) (c) (d) (e) (f)... 10 Electrical Data... 11 Cooling Only:... 11 Electrical Data... 12 Cooling Only:... 12 Electrical Data... 13 Cooling with Electric Heat:... 13 Electrical Data... 14 Compressor RLA Electrical Data:... 14 Evaporator Motor FLA:... 14 Condenser Motor FLA:... 14 Electric Heat FLA:... 14 Electrical Data Air-Cooled (c) (d) (e)... 15 Electrical Data Air-Cooled (c) (d)... 16 Electrical Data Water-Cooled (c) (d) (e)... 17 Electrical Data Water-Cooled (c) (d)... 18 Basic Unit Configurations... 19 Basic Unit Dimensions... 20 Cabinet Configurations and Unit Drawings... 21 23 Service Clearance... 24 Application Data... 25 Miscellaneous Technical Data... 25 Shipment Configurations... 26 28 BASIC MODEL DESIGNATION... 32 Subject to change without notice. 2

Product Features The VertiCool Classic Series of units are splittable, self-contained, floor mounted, single package units. They are available as air-cooled, water-cooled or as water source heat pump configurations. The units offer a variety of evaporator air flow patterns for application flexibility. Additionally, the units are available as standard configurations or they can be tailored for a specific application as a made-to-order unit. UNIT FEATURES Air-Cooled, Water-Cooled, Chilled Water or Water Source Heat Pump Configurations R-410a Refrigerant, Factory Charged 12 thru 30 Ton Units are Splittable using Resealable Refrigerant Fittings Fits through 32 doorways ½ Fiberglass Lined Cabinet (Thermal/Acoustical, min. density of 2 Pounds) Rugged cabinet construction Duct Flanges Factory Installed Drain Connections on Both Evaporator and Condensing Sections 304 Stainless Steel V Style Drain Pan in Evaporator Section.25 ESP Capability (1 ESP Option for Evaporator and Condensing Sections) Belt Driven Blowers (Evaporator and Condensing Sections) Ball Bearing Motors Resiliently Mounted Ball Bearings for Blowers Cast Iron Pulleys and Sheaves Variable Pitch Motor Sheaves All shafts, sheaves & pulleys keyed Adjustable Motor Mounts in Evaporator and Condensing Sections High (Manual Reset) and Low (Auto Reset) Refrigerant Pressure Safety Switches Loss of Air Safety Switch (when electric heat used) Scroll Compressors Adjustable Expansion Valve with External Equalizer (MOP Type) Sight Glass / Moisture Indicators Filter Driers High and Low Side Schrader Access Fittings Draw Through Air Flow Configuration Interlaced Evaporator Coils Single Electrical Control Box 24 Volt Control Circuits Transformer with Built In Circuit Breaker Individual Contactor for each Stage of Electric Heat Individual Contactor for each Motor and Compressor Co-axial Counter Flow Heat Exchanger(s) on Water-Cooled Units Limited Warranty 1 Year on Parts and 5 Years on Compressors Functionally Run Tested at the Factory OPTIONS: (Items in BOLD are factory installed): Powder Coated Cabinet Plenum w/ Discharge Grilles or Duct Flange Condensate Pump Electric Heat Protective Coil Coatings SCR Controllers Air or Water Side Economizer Hot Water, Chilled Water and Steam Coils Variable Frequency Drive (Evaporator) Drain Pan Overflow Switch Head Pressure Control Valves Double Wall Construction (Solid or Perforated) or Acoustic Foam Package Hot Gas Bypass (Standard or Modulating) Low Ambient Operation (VFD or Flooded Condenser) Freezestat Non-Fused Disconnects Thermostats Marvel Microprocessor Controls Upgraded Motors / Drive Sets Compressor Anti-Short Cycle Timer Quench Valve w/ Suction Accumulator Suction Line Accumulator Oil Separator Liquid Receivers Hot Gas Reheat Condenser Filter Box Return Air Grilles Chilled Water and Hot Water Valves Smoke Detectors Firestats Dry Contacts Steam Canister Humidifier CONTACT THE FACTORY FOR OTHER OPTIONAL FEATURES Subject to change without notice. 3

Physical Data Tons 3 4 5 8 10 Evaporator Supply Air CFM 1200 1600 2000 3200 4000 Evaporator Blower Size 10-8 Qty 1 2 Evaporator Motors (a) Std. HP @.25" ESP 1/3 1/2 1 2 Opt. HP @ 1.0" ESP 1/2 1 1-1/2 3 Rows 4 Evaporator Coil Face Area 4.44 9 FPI 12 Type Pleated Throwaway Filter Qty 2 1/2 Dimensions 20 x 20 x 2 16 x 25 x 2 / 20 x 25 x 2 Efficiency MERV 8 Compressor Type Scroll Qty 1 2 Condenser Air CFM 2100 2800 3500 6000 7500 Condenser Blower Size 10-8 15-9 Qty 2 Condenser Motors (a) Std. HP 1/2 1 1-1/2 2 5 Opt. HP 1/2 (c) 1-1/2 2 3 5 Rows 4 Condenser Coil Face Area 6 11.25 FPI 14 12 Water-Cooled Cond. (d) Type Co-axial Qty 1 2 Charge R-410A (Lbs-Ozs) (Charge per circuit) (e) Weight (Net Operating) (b) Available Voltages (e) Air-Cooled 13-0 12-13 12-9 25-6 24-10 Water-Cooled 5-6 5-10 5-13 11-7 11-14 Water Source HP 7-9 7-10 15-10 15-11 Air-Cooled 655 1150 Water-Cooled 480 940 Water Source HP 505 1000 208/230-1-60 - - - - - - 208/230-3-60 460-3-60 (a) Certain options may affect motor size. Run unit in UCA Select for proper motor HP. (b) Net operating weight is for basic unit only. Options will add weight. (c) Pulley & Belt upgrade only. (d) Contact factory for geothermal applications. (e) R-410A refrigerant charge is base unit configuration. Addition of some options may alter refrigerant amount. Subject to change without notice. 4

Physical Data Tons 12 15 20 25 30 (f) Evaporator Supply Air CFM 4800 6000 8000 9770 12000 Evaporator Blower Evaporator Motors (a) Evaporator Coil Filter Compressor Size 15-9 15-15 Qty 2 Std. HP @.25" ESP 1-1/2 2 5 7-1/2 Opt. HP @ 1.0" ESP 2 3 7-1/2 10 Rows 4 Face Area 13.33 17.8 22.6 FPI 10 12 Type Pleated Throwaway Qty 4 8 4 / 4 Dimensions 20 x 24 x 2 16 x 20 x 2 20 x 20 x 2 / 20 x 25 x 2 Efficiency MERV 8 Type Scroll Qty 2 Condenser Air CFM 7200 9000 12000 15000 16000 Condenser Blower Condenser Motors (a) Condenser Coil Water-Cooled Cond. (d) Charge R-410A (Lbs-Ozs) (Charge per circuit) (e) Weight (Net Operating) (b) Available Voltages Size 15-9 18-18 Qty 3 2 Std. HP @.25" ESP 2 3 7-1/2 15 10 Opt. HP @ 1.0" ESP 3 5 10 15 (c) 15 Rows 4 6 Face Area 20 22.7 FPI 12 Type Co-axial Qty 2 Air-Cooled 44-3 44-13 47-11 48-3 79-1 Water-Cooled 18-11 21-3 25-9 27-6 39-9 Water Source HP 23-12 25-14 33-3 33-10 58-7 Air-Cooled 1895 1945 1980 3400 Water-Cooled 1435 1485 1520 2700 Water Source HP 1495 1545 1580 3000 208/230-3-60 460-3-60 (a) Certain options may affect motor size. Run unit in UCA Select for proper motor HP. (b) Net operating weight is for basic unit only. Options will add weight. (c) Pulley & Belt upgrade only. (d) Contact factory for geothermal applications. (e) R-410A refrigerant charge is base unit configuration. Addition of some options may alter refrigerant amount (f) Units always shipped split Subject to change without notice. 5

Air-Cooled Performance Data (a) (b) (c) Entering Air Temp. ( F) Entering Air Temperature ( F) 75 95 115 Tons CFM DB WB Total Sensible Total Sensible Total Sensible 86 72 49530 32460 44430 30450 39570 28440 VA3G*ASTA 1200 80 67 45720 31730 41090 29770 36570 27750 75 62.5 42250 31390 38020 29460 33800 27410 72 60 40370 30880 36350 28980 32310 26920 86 72 59350 4400 53410 38020 47310 35580 VA4G*ASTA 1600 80 67 54780 39490 49450 37130 43860 34610 75 62.5 51120 39170 46230 36740 41000 34110 72 60 49160 38580 44460 36120 39400 33410 86 72 74040 49210 67700 46820 60370 43800 VA5G*ASTA 2000 80 67 67610 48140 61740 45610 55220 42570 75 62.5 62820 47760 57260 45000 51300 41850 72 60 60490 47110 55050 44220 49330 41000 86 72 122010 81650 110080 76870 97240 72070 VA8G*ATA 3200 80 67 112840 80150 101810 75280 90110 70080 75 62.5 104520 79520 94180 74560 83340 69030 72 60 99940 78350 89920 73400 79490 67730 86 72 148100 98720 133100 93280 117790 87300 VA10G*ATA 4000 80 67 137410 97040 123950 91360 110360 85260 75 62.5 127200 96280 114900 90300 102590 84030 72 60 121400 94730 109670 88630 97980 82300 86 72 186390 119960 170190 113980 151910 107220 VA12G*ATA 4800 80 67 173180 118360 158140 111630 141850 104270 75 62.5 161770 117900 147580 110750 132730 103150 72 60 155570 116310 141760 109120 127580 101530 86 72 225520 143950 204470 135610 182760 126740 VA15G*ATA 6000 80 67 209910 141970 190830 133400 171330 124390 75 62.5 195180 141140 177540 132320 159660 123130 72 60 186910 139180 169990 130240 152900 120990 86 72 300680 192350 274770 181380 244950 168900 VA20G*ATA 8000 80 67 279060 189450 254000 177860 225690 164880 75 62.5 260010 188340 235590 176070 208400 162540 72 60 249800 185820 225630 173180 198960 159360 86 72 334060 216720 311970 207290 282980 194850 VA25G*ATA 10000 80 67 313120 214000 290510 203170 262260 189640 75 62.5 292590 213540 269940 201530 242520 187030 72 60 280950 211260 258300 198650 231330 183690 86 72 441490 294480 403140 279420 361840 262540 VA30G*ATA 12000 80 67 413100 290100 376410 274030 337790 256410 75 62.5 383920 287380 349040 270240 313000 251830 72 60 367140 282490 333340 264850 298770 246090 Notes: (a) Capacities are gross values, not adjusted for motor heat. (b) Some refrigerant circuit components may impact on unit capacities. (c) Applications with ambient conditions 75 F and lower may require additional refrigerant circuit components. Consult factory for details. Subject to change without notice. 6

Water-Cooled Performance Data (a) (c) (d) (e) Entering Water Temperature ( F) Entering Air Temp. ( F) PD 80 85 90 Tons GPM (Ft. H2O) (b) CFM DB WB Total Sensible Total Sensible Total Sensible 86 72 50170 32820 48920 32290 47670 31770 VW3G*ASTA 9 9.8 1200 80 67 46180 32010 45070 31480 43950 30970 75 62.5 42800 31690 41780 31170 40760 30660 72 60 41010 31230 40030 30720 39060 30220 86 72 62130 41510 60600 40930 59030 40330 VW4G*ASTA 12 14.7 1600 80 67 57730 40500 56270 39880 54780 39240 75 62.5 53560 40080 52170 39410 50763 38730 72 60 51250 39480 49900 38800 48530 38100 86 72 78660 51540 75350 50110 73550 49350 VW5G*ASTA 15 10.9 2000 80 67 71930 49950 68770 48430 67080 47620 75 62.5 67300 49560 64330 47950 62740 47110 72 60 63820 48270 62360 47440 60840 46580 86 72 125900 83930 122580 82710 119200 81460 VW8G*ATA 24 8.8 3200 80 67 116250 81660 113240 80380 110170 79070 75 62.5 107950 80730 105170 79370 102350 77980 72 60 103490 79550 100830 78140 98120 76700 86 72 157390 103200 153710 101620 149900 99970 VW10G*ATA 30 10.2 4000 80 67 152700 110740 140010 98180 136450 96550 75 62.5 132260 98100 129010 96520 125660 94890 72 60 126550 96420 123400 94850 120150 93220 86 72 194460 123580 189820 121710 185110 119810 VW12G*ATA 36 8.8 4800 80 67 178880 120820 174630 118890 170310 116940 75 62.5 166040 119950 162090 117950 158080 115930 72 60 159460 118550 155660 116530 151800 114470 86 72 236600 148890 230900 146700 224980 144460 VW15G*ATA 45 14.0 6000 80 67 215530 144944 210560 142770 205420 140550 75 62.5 199860 143670 195460 141510 190910 139300 72 60 192310 141970 188200 139820 183950 137620 86 72 309690 196820 302830 194000 295810 191120 VW20G*ATA 60 11.0 8000 80 67 287370 193460 280700 190450 273900 187390 75 62.5 128120 192490 261620 189300 255020 186070 72 60 257760 190230 251360 186960 244860 183630 86 72 361890 227730 355210 225000 348190 222160 VW25G*ATA 75 13.0 10000 80 67 332270 222840 326080 220020 319600 217100 75 62.5 308820 221240 303000 218330 296920 215310 72 60 297010 218600 294380 215630 285510 212570 86 72 462560 306240 455220 303160 440290 296510 VW30G*ATA 90 8.0 12000 80 67 425770 296320 417770 292700 401640 285040 75 62.5 397690 293530 389350 289460 372610 280970 72 60 384130 290540 375660 286270 358740 277380 Notes: (a) Capacities are gross values, not adjusted for motor heat. (b) Pressure drop is for heat exchanger only and does not include piping, valves, fittings, etc. (c) Some refrigerant circuit components may impact on unit capacities. (d) Applications with water conditions 75 F and lower may require additional refrigerant circuit components. Consult factory for details. (e) Contact factory for geothermal applications. Subject to change without notice. 7

Water Source Heat Pump Performance Data (a) (c) (d) (e) Tons GPM CFM VW3G*ATA 9 1200 VW4G*ATA 12 1600 VW5G*ATA 15 2000 VW8G*ATA 24 3200 VW10G*ATA 30 4000 VW12G*ATA 36 4800 VW15G*ATA 45 6000 VW20G*ATA 60 8000 VW25G*ATA 75 10000 VW30G*ATA 90 12000 Entering Air Temp. ( F) DB Heating Capacity 70 50100 60 51100 70 62500 60 64000 70 78400 60 80100 70 94500 60 96500 70 116600 60 119100 70 136500 60 139400 70 178500 60 182300 70 225800 60 230700 70 275800 60 281800 70 358400 60 366200 Notes: (a) Capacities are gross values, not adjusted for motor heat. (b) Pressure drop is for heat exchanger only and does not include piping, valves, fittings, etc. (c) Some refrigerant circuit components may impact on unit capacities. (d) Values at 70 F Entering Water Temperature. (e) Contact factory for geothermal applications. Subject to change without notice. 8

Blower Performance Data Evaporator (a) (b) External Static Pressure (ESP) Tons CFM 0.25 0.25 to 1.0 3 1200 0.33 0.5 4 1600 0.5 1.0 5 2000 1.0 1.5 8 3200 1.0 1.5 10 4000 2.0 3.1.5 12 4800 1.5 2 15 6000 2.0 3 20 8000 5 5 (c) 1.0 1.0 to 2.0 25 9770 7.5 10 30 12000 7.5 10 Condenser Notes: (a) Blower performance of basic unit with 2, MERV 8 pleated throwaway filter and wet coil 80 / 67 / 95 and A air path. (b) Performance with nominal CFM. For other CFM or ESP contact the factory for your specific application. (c) Pulley & Belt upgrade only. Steam Coil External Static Pressure (ESP) Tons CFM 0.25 0.25 to 1.0 3 0.5 1.0 4 1.0 1.5 5 1.5 2.0 (@ 0.9 max) 8 4800 2 3 10 6000 5 5 12 7200 2 3 15 9000 3.0 5 20 12000 7.5 7.5 (c) 25 15000 15 15 1.0 1.0 to 2.0 30 16000 10 15 Notes: (a) Contact factory with steam pressure and operating parameters. (b) Low pressure, less than 10 psig. (c) Steam valves and components by others, field installed (d) Requires addition of optional discharge plenum for 12 thru 30 Ton units if steam coil is being used for reheat and air path is A or B (top supply). Subject to change without notice. 9

Hot Water Coil Performance (a) (b) (c) (d) (e) (f) (g) Tons CFM GPM PD Ft. H2O Capacity (MBH) 3 1200 5 2.6 48900 4 1600 5.9 3.6 58000 5 2000 6.8 4.7 66200 8 3200 18.1 3.4 174000 10 4000 21.0 4.4 204400 12 4800 23.5 5.4 228500 15 6000 27.0 7.0 262500 20 8000 32.0 9.7 312400 25 9770 35.0 12.4 340700 30 12000 36.0 14.8 350500 Notes: (a) Hot Water Coil Valves are optional. (b) Valves are spring return, On / Off operation only. (c) Entering water at 180 F. Leaving water at approximately 160 F. (d) Entering air temperature 65 F. (e) For other operating conditions or fluid type, contact the factory for performance. (f) Requires addition of optional discharge plenum for 12 thru 30 Ton units if hot water coil is being used for reheat and air path is A or B (top supply). (g) Hot Water Coil Valve Sizes: Tons Valve Size 8 3/4 10 1 12 1-1/4 15 1-1/4 20 1-1/4 25 1-1/2 30 Contact Factory Chilled Water Coil Performance (a) (b) (c) (d) (e) (f) Tons CFM GPM PD Ft. H2O Total (MBH) Sensible (MBH) 3 1200 10 4.4 46900 33200 4 1600 12 6.1 57000 41700 5 2000 13 7.1 64700 49100 8 3200 19 5.0 101800 75700 10 4000 24 8.0 120600 90700 12 4800 30 5.5 155400 114700 15 6000 35 7.0 179500 135400 20 8000 45 5.0 238100 180300 25 10000 62 7.5 310500 230800 30 12000 72 8.0 369400 276300 Notes: (a) Capacity based on 80 F DB / 67 F WB with 45 F EFT. (b) Chilled water entering at 45 F. (c) For other operating conditions or fluid type, contact the factory for performance. (d) Chilled Water Coil Valves are optional. (e) Valves are spring return, On / Off operation only. (f) Chilled Water Coil Valve Sizes: Tons Valve Size 8 1-1/4 10 1-1/4 12 1-1/2 15 2 20 2-1/2 25 2-1/2 30 2-1/2 Subject to change without notice. 10

Electrical Data The following sections provides the formulas and the data to calculate the Minimum Circuit Ampacity (MCA) and the Maximum Fuse Size (MOP) for your specific unit configuration. There are a variety of unit configurations. Please make sure to use the correct formulas per your configuration. It must be noted that the formulas refer to the largest motor amps. This typically is the compressor (RLA), but it can also be one of the blower motors (FLA). The data provided will cover the majority of available unit configurations. However, it should be noted that additional combinations may be available and the factory can be contacted for this data. Examples have also been provided for each configuration. RLA = Compressor Rated Load Amps FLA = Full Load Amps (Used for Blower Motors and Electric Heaters) MCA = Minimum Circuit Ampacity (Calculated value) MOP = Maximum Fuse Size (Calculated value) Cooling Only: Package Unit NOTE: Largest motor amps may not always be the compressor. MCA = (1.25 x largest motor amps) + the sum of the remaining motors MOP = (2.25 x largest motor amps) + the sum of remaining motors Condensing Section w/ Compressor(s) NOTE: Largest motor amps may not always be the compressor. MCA = (1.25 x largest motor amps) + the sum of the remaining motors MOP = (2.25 x largest motor amps) + the sum of remaining motors Evaporator Only Section MCA = (1.25 x Evap. Blower Motor Amps) MOP = (2.25 x Evap. Blower Motor Amps) Condenser Only Section w/o Compressor(s) MCA = (1.25 x Cond. Blower Motor Amps) MOP = (2.25 x Cond. Blower Motor Amps) Evaporator Section w/ Compressor(s) NOTE: Largest motor amps may not always be the compressor. MCA = (1.25 x largest motor amps) + the sum of the remaining motors MOP = (2.25 x largest motor amps) + the sum of remaining motors Subject to change without notice. 11

Electrical Data Examples Cooling Only: Package Unit NOTE: Largest motor amps may not always be the compressor. MCA = (1.25 x largest motor amps) + the sum of the remaining motors MOP = (2.25 x largest motor amps) + the sum of remaining motors Dual Compressors RLA = 19.2 each Evap. Blower Motor FLA = 4.8 Cond. Blower Motor FLA = 9.2 MCA = (1.25 x 19.2) + 19.2 + 4.8 + 9.2 = 57.2 MOP = (2.25 x 19.2) + 19.2 + 4.8 + 9.2 = 76.4 Rounded Down to 75 Condensing Section w/ Compressor(s) NOTE: Largest motor amps may not always be the compressor. MCA = (1.25 x largest motor amps) + the sum of the remaining motors MOP = (2.25 x largest motor amps) + the sum of remaining motors Dual Compressors RLA = 19.2 each Cond. Blower Motor FLA = 13.6 MCA = (1.25 x 19.2) + 19.2 + 13.6 = 56.8 MOP = (2.25 x 19.2) + 19.2 + 13.6 = 76 Rounded Down to 75 Evaporator Only Section MCA = (1.25 x Evap. Blower Motor Amps) MOP = (2.25 x Evap. Blower Motor Amps) Evap. Blower Motor FLA = 4.8 MCA = (1.25 x 4.8) = 6.0 MOP = (2.25 x 4.8) = 10.8 Rounded Down to 10 Condenser Only Section w/o Compressor(s) MCA = (1.25 x Cond. Blower Motor Amps) MOP = (2.25 x Cond. Blower Motor Amps) Cond. Blower Motor FLA = 9.2 MCA = (1.25 x 9.2) = 11.5 MOP = (2.25 x 9.2) = 20.7 Rounded Down to 20 Evaporator Section w/ Compressor(s) NOTE: Largest motor amps may not always be the compressor. MCA = (1.25 x largest motor amps) + the sum of the remaining motors MOP = (2.25 x largest motor amps) + the sum of remaining motors Dual Compressors RLA = 23.2 each Evap. Blower Motor FLA = 13.6 MCA = (1.25 x 23.2) + 23.2 + 13.6 = 65.8 MOP = (2.25 x 23.2) + 23.2 + 13.6 = 89 Rounded Down to 85 Subject to change without notice. 12

Electrical Data Cooling with Electric Heat: Package Unit NOTE: Largest motor amps may not always be the compressor. Electric Heat On equipment with multiple modes of operation (i.e. cooling or heating), each mode shall be evaluated and whichever load condition provides the highest value shall be used. Use the larger of the following: MCA = (1.25 x largest motor amps) + the sum of the remaining motors or MCA = (Heater FLA + Evap. Motor FLA) x 1.25 MOP = (2.25 x largest motor amps) + the sum of the remaining motors or MOP = (Evap. Blower Motor x 2.25) + Heater Amps Evaporator Only Section Electric Heat MCA = (Heater FLA + Evap. Motor FLA) x 1.25 MOP = (Evap. Blower Motor x 2.25) + Heater Amps Evaporator Section w/ Compressor(s) - - Same as Package Unit above Condensing Section w/ Compressor(s) or Condenser Only Section w/o Compressor(s) same as Cooling Only models Examples Cooling with Electric Heat: Single Package NOTE: Largest motor amps may not always be the compressor. Electric Heat Use the larger of the following: MCA = (1.25 x 19.2) + 19.2 + 6.6 + 6.8 = 57.2 or MCA = (41.2 + 4.8) x 1.25 = 57.5 Use this value MOP = (2.25 x 19.2) + 19.2 + 4.8 + 9.2 = 76.4 Use this value Rounded Down to 75 or MOP = (4.8 x 2.25) + 41.2 = 52 Evaporator Only Section Electric Heat MCA = (41.2 + 4.8) x 1.25 = 57.5 MOP = (4.8 x 2.25) + 41.2 = 52 MOP can t be lower than MCA Rounded Up to 60 Evaporator Section w/ Compressor(s) - - Same as Single Package above Subject to change without notice. 13

Electrical Data Engineering Guide Compressor RLA Electrical Data: Tons Compressor (Qty) 208/230-1-60 208/230-3-60 460-3-60 3 17.9 13.5 6.0 4 1 21.4 14.5 6.3 5 28.3 19.2 8.7 8-14.5 ea. 6.3 ea. 10-19.2 ea. 8.7 ea. 12-23.2 ea. 11.2 ea. 15 2-29.5 ea. 14.7 ea. 20-33.3 ea. 17.9 ea. 25-48.1 ea. 18.6 ea. 30-55.8 ea. 26.9 ea. Evaporator Motor FLA: HP Used In Tons 208/230-1-60 208/230-3-60 460-3-60 0.33 3.0 1.6 0.8 0.5 3 5 3.8 2.2 1.0 0.75 5.8 3.2 1.5 1.0 3 10 7.0 3.4 1.6 1.5 3 12 9.4 4.8 2.4 2 3 15 11.3 6.2 3.1 3 8 20-9.2 4.3 5 12 30-13.6 6.3 7.5-21.0 9.6 10 20 30-27.0 12.5 15-40.6 18.5 Condenser Motor FLA: HP Used In Tons 208/230-1-60 208/230-3-60 460-3-60 0.5 3.8 2.2 1.0 0.75 3 5 5.8 3.2 1.5 1 7.0 3.4 1.6 1.5 3 12 9.4 4.8 2.4 2 3 15 11.3 6.2 3.1 3 8 20-9.2 4.3 5 8 30-13.6 6.3 7.5-21.0 9.6 10 12 30-27.0 12.5 15-40.6 18.5 Electric Heat FLA: (Heaters nominally rated at 220 or 277 volts. Amps listed at 208, 230 and 460 volts) Nom. kw Stages Used In Tons 208-3-60 230-3-60 460-3-60 5 1 3, 4 22.7 13.1 6.3 10 8 45.5 26.2 12.6 1 or 2 15 8, 10, 12-39.4 18.8 20 (a) 8, 10, 12, 15, 20-52.5 25.1 25 (a) 8, 10, 12, 15, 20, 25, 30-65.6 31.4 2 30 (a) 10, 12, 15, 20, 25, 30-78.7 37.7 45 (a) 15, 20, 25, 30-118.1 56.5 Notes: (a) If electric heater will be used as reheat in a 12 thru 30 Ton unit and the air path is A or B (top supply), an optional discharge air plenum is required Contact factory for 575 volt data. Subject to change without notice. 14

Electrical Data Air-Cooled (c) (d) (e) Tons Voltage Compressor RLA Evaporator Motor Condenser Motor Electrical Heat (a) (b) HP FLA HP FLA Nom. KW Amps MCA MOP 208/230-3-60 13.5 VA3G*ASTA 460-3-60 6 208/230-3-60 14.5 VA4G*ASTA 460-3-60 6.3 208/230-3-60 19.2 VA5G*ASTA 460-3-60 8.7 VA8G*ATA VA10G*ATA 208/230-3-60 14.5 ea. 460-3-60 6.3 ea. 208/230-3-60 19.2 ea. 460-3-60 8.7 ea. 1.5 4.8 2 6.2 - - - - - - 43.6 55 2 6.2 3 9.2 - - - - - - 48.0 60 1.5 4.8 2 6.2 10 27.4 43.6 55 2 6.2 3 9.2 25 68.6 93.5 95 1.5 2.4 2 3.1 - - - - - - 19.7 25 2 3.1 3 4.3 - - - - - - 21.6 25 1.5 2.4 2 3.1 10 11.5 19.7 25 2 3.1 3 4.3 25 28.8 39.9 40 1.5 4.8 3 9.2 - - - - - - 57.2 75 2 6.2 5 13.6 - - - - - - 63.0 80 1.5 4.8 3 9.2 15 41.2 57.5 75 2 6.2 5 13.6 30 82.3 110.6 115 1.5 2.4 3 4.3 - - - - - - 26.3 30 2 3.1 5 6.3 - - - - - - 29.0 35 1.5 2.4 3 4.3 15 17.3 26.3 30 2 3.1 5 6.3 30 34.6 47.1 50 Notes: (a) Electric heaters nominally rated at 220 or 277 volts. Amps listed at 230 or 460 volts. (b) Electric heaters listed being used for heat. (c) Use Copper Conductors Only. (d) Values listed are typical and may vary dependent upon components utilized. (e) All unit electrical capabilities not shown. Contact factory for specific unit combinations. Subject to change without notice. 15

Electrical Data Air-Cooled (c) (d) Tons 12 15 20 25 30 Voltage 208/230-3-60 Compressor RLA 23.2 ea. 460-3-60 11.2 ea. 208/230-3-60 29.5 ea. 460-3-60 14.7 ea. 208/230-3-60 33.3 ea. 460-3-60 17.9 ea. 208/230-3-60 48.1 ea. 460-3-60 18.6 ea. 208/230-3-60 55.8 ea. 460-3-60 26.9 ea. Evaporator Motor Condenser Motor Electrical Heat (a) (b) HP FLA HP FLA Nom. KW Amps MCA MOP 3 9.2 5 13.6 - - - - - - 75.0 95 5 13.6 5 13.6 - - - - - - 79.4 100 3 9.2 5 13.6 15 41.2 75.0 95 5 13.6 5 13.6 30 82.3 119.9 120 3 4.3 5 6.3 - - - - - - 35.8 45 5 6.3 5 6.3 - - - - - - 37.8 45 3 4.3 5 6.3 15 17.3 35.8 45 5 6.3 5 6.3 30 34.6 51.1 55 3 9.2 5 13.6 - - - - - - 89.2 115 5 13.6 7.5 21.0 - - - - - - 101.0 130 3 9.2 5 13.6 20 54.8 89.2 115 5 13.6 7.5 21.0 45 123.5 171.4 175 3 4.3 5 6.3 - - - - - - 43.7 55 5 6.3 7.5 9.6 - - - - - - 49.0 60 3 4.3 5 6.3 20 23.0 43.7 55 5 6.3 7.5 9.6 45 51.9 72.8 75 3 9.2 5 13.6 - - - - - - 97.7 130 5 13.6 7.5 21.0 - - - - - - 109.5 140 3 9.2 5 13.6 20 54.8 97.7 130 5 13.6 7.5 21.0 45 123.5 171.4 175 3 4.3 5 6.3 - - - - - - 50.9 65 5 6.3 7.5 9.6 - - - - - - 56.2 70 3 4.3 5 6.3 20 23.0 50.9 65 5 6.3 7.5 9.6 45 51.9 72.8 75 10 27.0 10 27.0 - - - - - - 162.2 210 15 40.6 15 40.6 - - - - - - 189.4 235 10 27.0 10 27.0 25 68.6 162.2 210 15 40.6 15 40.6 45 123.5 205.1 235 10 12.5 10 12.5 - - - - - - 66.9 85 15 18.5 15 18.5 - - - - - - 78.9 95 10 12.5 10 12.5 25 28.8 66.9 85 15 18.5 15 18.5 45 51.9 88.0 95 10 27.0 15 40.6 - - - - - - 193.2 245 15 40.6 15 40.6 - - - - - - 206.8 260 10 27.0 15 40.6 25 68.6 193.2 245 15 40.6 15 40.6 45 123.5 206.8 260 10 12.5 15 18.5 - - - - - - 91.5 115 15 18.5 15 18.5 - - - - - - 97.5 120 10 12.5 15 18.5 25 28.8 91.5 115 15 18.5 15 18.5 45 51.9 97.5 120 Notes: (a) Electric heaters nominally rated at 220, 460 or 575 volts. Amps listed at 220, 460 or 575 volts. (b) Electric heaters listed being used for heat. (c) Use Copper Conductors Only. (d) Values listed are typical and may vary dependent upon components utilized. Subject to change without notice. 16

Electrical Data Water-Cooled (c) (d) (e) Tons Voltage Compressor RLA Evaporator Motor Electrical Heat (a) (b) HP FLA Nom. KW Amps MCA MOP 3 4 5 8 10 208/230-3-60 14.5 ea. 460-3-60 6.3 ea. 208/230-3-60 19.2 ea. 460-3-60 8.7 ea. 1.5 4.8 - - - - - - 37.4 50 2 6.2 - - - - - - 38.8 50 1.5 4.8 10 27.4 40.3 50 2 6.2 25 68.6 93.5 95 1.5 2.4 - - - - - - 16.6 20 2 3.1 - - - - - - 17.3 20 1.5 2.4 10 11.5 17.4 20 2 3.1 25 28.8 39.9 40 1.5 4.8 - - - - - - 48.0 65 2 6.2 - - - - - - 49.4 65 1.5 4.8 15 41.2 57.5 65 2 6.2 30 82.3 110.6 115 1.5 2.4 - - - - - - 22.0 30 2 3.1 - - - - - - 22.7 30 1.5 2.4 15 17.3 24.6 30 2 3.1 30 34.6 47.1 50 (a) Electric heaters nominally rated at 220, 460 or 575 volts. Amps listed at 220, 460 or 575 volts. (b) Electric heaters listed being used for heat. (c) Use Copper Conductors Only. (d) Values listed are typical and may vary dependent upon components utilized. (e) All unit electrical capabilities not shown. Contact factory for specific unit combinations. Subject to change without notice. 17

Electrical Data Water-Cooled (c) (d) Engineering Guide Tons 12 15 20 25 30 Voltage Compressor RLA 208/230-3-60 23.2 ea. 460-3-60 11.2 ea. 208/230-3-60 29.5 ea. 460-3-60 14.7 ea. 208/230-3-60 33.3 ea. 460-3-60 17.9 ea. 208/230-3-60 48.1 ea. 460-3-60 18.6 ea. 208/230-3-60 55.8 ea. 460-3-60 26.9 ea. Evaporator Motor Electrical Heat (a) (b) HP FLA Nom. KW Amps MCA MOP 3 9.2 - - - - - - 61.4 80 5 13.6 - - - - - - 65.8 85 3 9.2 15 41.2 63.0 80 5 13.6 30 82.3 119.9 120 3 4.3 - - - - - - 29.5 40 5 6.3 - - - - - - 31.5 40 3 4.3 15 17.3 29.5 40 5 6.3 30 34.6 51.1 55 3 9.2 - - - - - - 75.6 105 5 13.6 - - - - - - 80.0 105 3 9.2 20 54.8 80.0 105 5 13.6 45 123.5 171.4 105 3 4.3 - - - - - - 37.4 50 5 6.3 - - - - - - 39.4 50 3 4.3 20 23.0 37.4 50 5 6.3 45 51.9 72.8 75 3 9.2 - - - - - - 84.1 115 5 13.6 - - - - - - 88.5 120 3 9.2 20 54.8 84.1 115 5 13.6 45 123.5 171.4 175 3 4.3 - - - - - - 44.6 60 5 6.3 - - - - - - 46.6 60 3 4.3 20 23.0 44.6 60 5 6.3 45 51.9 72.8 75 10 27.0 - - - - - - 135.2 180 15 40.6 - - - - - - 148.8 195 10 27.0 25 68.6 135.2 180 15 40.6 45 123.5 205.1 215 10 12.5 - - - - - - 54.4 70 15 18.5 - - - - - - 60.4 75 10 12.5 25 28.8 54.4 70 15 18.5 45 51.9 88.0 95 10 27.0 - - - - - - 152.6 205 15 40.6 - - - - - - 166.2 220 10 27.0 25 68.6 152.6 205 15 40.6 45 123.5 205.1 220 10 12.5 - - - - - - 73.0 95 15 18.5 - - - - - - 79.0 105 10 12.5 25 28.8 73.0 95 15 18.5 45 51.9 88.0 105 (a) Electric heaters nominally rated at 220, 460 or 575 volts. Amps listed at 220, 460 or 575 volts. (b) Electric heaters listed being used for heat. (c) Use Copper Conductors Only. (d) Values listed are typical and may vary dependent upon components utilized. (e) All unit electrical capabilities not shown. Contact factory for specific unit combinations. Subject to change without notice. 18

Basic Unit Configurations Subject to change without notice. 19

Basic Unit Dimensions TONS A B C D E F G 3, 4, 5 60 ½ 44 29 12 8 & 10 73 ⅝ 62 32 12 27 ⅞ 45 ¾ 5 12 & 15 79 ¼ 88 ¼ 32 ¼ 12 28 ¼ 51 4 20 & 25 87 ¼ 88 ¼ 32 ¼ 12 36 ¼ 51 5 30 98 ⅛ 96 ¼ 42 7 32 24 42 1 16 56 1 16 6 For specific unit dimensions, please visit our website at www.unitedcoolair.com/classic-drawings or click here if you are viewing this document electronically. Subject to change without notice. 20

Cabinet Configurations and Unit Drawings Not to Scale Subject to change without notice. 21

Cabinet Configurations and Unit Drawings Not to Scale Subject to change without notice. 22

Cabinet Configurations and Unit Drawings Not to Scale For specific unit dimensions, please visit our website at www.unitedcoolair.com/classic-drawings or click here if you are viewing this document electronically. Subject to change without notice. 23

Service Clearance (Plan View) Notes: (a) If evaporator is not ducted, maintain a 24 clearance from the wall for air intake. (b) Control box location may change or it could be located externally. Subject to change without notice. 24

Application Data Voltage 208 / 230 460 575 Variation 187 / 253 414 / 504 518 / 632 Cooling (Air Entering Evaporator) DB (min./max.) 65 / 110 WB (min./max) 57 / 72 Note: Not all combinations may be valid Water-Cooled GPM / Ton (min./max.) 2.5 / 3.5 Leaving Water Temp (min./max) 60 / 115 Note: Not all combinations may be valid Miscellaneous Technical Data Water-Cooled Units Female Pipe Threads (FPT) Water Connection Sizes Tons Size 8 1 10-12 1-1/4 15 1-1/2 20-30 2-1/2 Condensate Drain Pipes: 3/4 IPS Notes: Reference United CoolAir s Louver and Ducting Guidelines TechTip for proper selection andapplication of wall louvers. You can view it on our website at www.unitedcoolair.com/ tips or click here if you are reading this document electronically. Subject to change without notice. 25

Shipment Configurations Subject to change without notice. 26

Shipment Configurations Subject to change without notice. 27

Shipment Configurations Subject to change without notice. 28

NOTES: Subject to change without notice. 29

NOTES: Subject to change without notice. 30

NOTES: Subject to change without notice. 31

BASIC MODEL DESIGNATION EXAMPLE: VW a b 8 c G d 3 e AS f T g A h A j X k a. VA, VW, VHW, E, BVA, BCVA, BVW or VCW VA Air-Cooled Air Conditioner VW Water-Cooled Air Conditioner VHW Water Source Heat Pump E Evaporator Section only as a prefix to any of the above BVA Air-Cooled Condensing Section BCVA Air-Cooled Condenser Section BVW Water-Cooled Condensing Section VCW Chilled Water Air Handler b. R or RC Remote Condenser or Condensing Section Being Used R Remote Condenser Unit being used RC Remote Condensing Unit being used c. 8, 10, 12, 15, 20, 25, 30 Nominal Cooling Capacity in Tons d. G Common to all e. 3, 4 or 5 Indicates Voltage 3 208-230V, 3 PH 4 460V, 3 PH 5 575V, 3 PH f. AS, A Quantity of Refrigerant Circuits AS Indicates 1 Circuit A Indicates 2 Circuits g. T Cabinet Series h. A Refrigerant Type A R-410a i. 05, 10, 15, 20, 25, 30, 45 Indicates kw Rating for Heaters j. -A, -APF, -APT, -APR, -B, -BPF, -BPT, -BPR, -C, -D Indicates Air Path Configuration k. X Special Configuration Not all combinations of Basic Model Designations are valid. Check with the factory for correct model identification. Subject to change without notice. 32

Unique Solutions for All-Indoor HVAC Projects VertiCool Classic Vertical, 3-30 Ton VertiCool Aurora Vertical, 3-35 Tons VariCool VAV, 9-70 Tons VariCool EZ-Fit VAV, 12-90 Tons Alpha Aire 100 500 CFM Portable Cooling and Heating Units 3-30 Tons C13-Series Horizontal 2-10 Tons C-Series Horizontal 1-15 Tons Special Configuration Engineered to Order OmegaAir Horizontal and Vertical 100% Outside Air 150 3000 CFM Authorized Distributor: LIMITED WARRANTY United CoolAir Units are backed by a 1 year limited warranty on parts and a 5 year limited warranty on the compressor (labor not included). Maintenance items such as filters and belts are excluded under this limited warranty. FACTORY TESTED All units are functionally run tested before shipment to ensure a trouble-free start-up and unit commissioning. Industry proven components are used throughout to enhance system reliability and peace of mind. Scan to learn more about all of our products! 491 East Princess Street, York, PA 17403 Phone: 717-843-4311 Fax: 717-854-4462 email: uca@unitedcoolair.com web: www.unitedcoolair.com Copyright by United CoolAir Corporation 2018. All rights reserved. Manufacturer reserves the right to make changes without notice.