LI-830 and LI-850 Gas Analyzers. For Continuous Monitoring Applications

Similar documents
LI-830 and LI-850 Gas Analyzers. For Continuous Monitoring Applications

LI-8150 Multiplexer For the LI-8100A Automated Soil CO 2 Flux System. Connect Multiple Chambers for Spatial and Temporal Sampling

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

Model OEM-2 INSTRUCTIONS FOR USE

Ventostat Wall Mount. Amphenol Advanced Sensors. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Features:

SEC SIGNATURE ETO MONITOR TRAINING SENSOR ELECTRONICS CORPORATION

Datasheet: K-22 LO Sensor

Key Features. General Description

Accuracy by Design Products for the HVAC Professional

Ventostat Wall Mount. Amphenol. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Advanced Sensors. Features:

MICROCAPSTAR End-Tidal CO 2 Analyzer Instruction Manual

Dew-Point Transmitters and Instruments

Climate chambers with illumination and humidity The BINDER KBWF series shines with its

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

OEM REFRIGERANT GAS SENSORS for Leak Detection & Measurement

Constant climate chambers

OPERATING AND MAINTENANCE MANUAL. for the G30 CARBON DIOXIDE MONITOR

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

Dräger PIR 7200 Toxic Gas Detection Transmitter

Mercury Vapor Monitor VM-3000

Constant climate chamber with humidity

Intelligent Infrared Carbon Dioxide Module (Model: MH-Z14A)

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

Environmental simulation chamber for complex alternating climate profiles

SEC Signature Process Gas Analyzer

Constant climate chamber with ICH-compliant illumination

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

Series 155. Mass Flow Computers TECHNICAL SPECIFICATIONS

Danfoss gas detection unit Type GD Heavy Duty

SAM-MAX Refrigerant Monitors

Model D12-IR. Digital Gas Transmitter...

PROCESS ANALYSERS. SERVOFLEX MiniMP (5200) Gas Analyser. Operator Manual. Part Number: A Revision: 8 Language: UK English

for Drinking Water Systems

VM-3000 Mercury Vapor Monitor

WASTEWATER Online UV%Transmission Analyzer

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000

Using the Model 1500 Portable Chilled Mirror Hygrometer

Using the DewMaster Deluxe Dew Point/ Humidity Hygrometer

VM-3000 Mercury Vapor Monitor

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

Air Quality Sensors. Particle Matter, CO 2, Humidity, Temperature and Dust Products. OEM Sensor Components for Air Quality and Environmental Control

Infrared Moisture Balance (FD-800)

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

MODEL DPS1 Heated Dew Point Measuring System OPERATORS MANUAL

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

Model CB 220 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

incubator, the best in its class

Dräger REGARD -1 Control System

Falcon-II Next Generation, Air Quality Monitor CO2 & Temperature

Using the DewTrak II Dew Point/ Humidity Transmitter

Constant climate chambers

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

Recalibrate the way you look at gas detection

SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES

DP86 Constant Voltage with Fitting

SECTION Fluorescent Dissolved Oxygen Measuring System

SafEye OPEN-PATH GAS DETECTION SYSTEM XENON 700. We INVENTED it... We PERFECTED it! Patent No. US 5,281,816; US 6,061,141; EP

Hydrazine Analyzer Series 2171 Specifications

89BSD Digital Output

Dräger Polytron Pulsar 2 Open Path Gas Detector

Altanium Temperature Controllers

Industrial Grade Gas Detection

LC150 VIEW-AT-A-GLANCE PUMP CONTROL-TELEMETRY UNIT

Constant climate chambers

Product Catalogue. Air and Gas Sensors. Save Life and Energy

Mass Sensors, Inc. Profile. Applications. Technology Baur Blvd, St. Louis, MO (314)

86BSD Digital Output

CONTAMINATION CONTROL FOR ELECTRONIC AND SEMICONDUCTOR APPLICATIONS

SprintIR -6S CO2 Sensor

IR25 Dual Gas Series Datasheet

KANE-ALERT-CO 2 Monitor with Temperature

A New Standard of Excellence

HFID Heated Total Hydrocarbon Analyzer Module

16S-Series 150W. In Vivo SPF Sunscreen Testing Solar Simulator

86BSD Digital Output

Black Body Calibration Source User Manual

Model 6650SP. Filber Optic-Based UV-Fluorescence Oil-in-Water Analyzer

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

SprintIR -W CO2 Sensor

RPM1600 Series Room Pressure Monitors

C7232A,B Sensor and Controller CARBON DIOXIDE SENSOR

DESCRIPTION AND SPECIFICATION

MICHELL GROUP. Advanced Industrial Hygrometry and Process Instrumentation. Company Profile, 2011

MEMS Accelerometer ICs. AMR Magnetic Sensor ICs. Gas Flow Modules. Differential Pressure Sensors. Tilt Modules. Current Sensors

SIL 2. Ultima X Series Gas Monitors CERTIFIED

IR200 INFRARED HCFC & AMMONIA (NH3) REFRIGERANT SENSOR. User Manual

Toxic Gas Detection. Model F12. Toxic Gas Detection

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Series 3300 TELEDYNE ANALYTICAL INSTRUMENTS. The 3300 series of low cost, microprocessorbased

Danfoss gas detection units

COBRIX3 multibev. Online Beverage Analyzer. ::: Unique Density & Concentration Meters

Industrial Grade Gas Detection Detecting The Difference

IRtech. E instruments. IRtech Radiamatic IR20 LS series. Infrared Technology

SAFEYE XENON 700. Hydrocarbons and ethylene detection. Heated optics. 10-year Warranty for the Xenon flash bulb. SIL 2 according to IEC 61508

PrimaX IR Gas Transmitter Designed for Reliable Performance in Extreme Conditions

4500MkIII COMPLIANCE OPACITY AND DUST MONITORING QAL 1 PS-1 ASTM D6216 PROCEDURE 3 PS-11 QUALITY CUSTOMER SOLUTIONS

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

Transcription:

LI-830 and LI-850 Gas Analyzers For Continuous Monitoring Applications

Easy Operation The LI-830 CO2 and LI-850 CO2/H2O Analyzers are high-performance monitoring solutions that give accurate, stable readings. Easy-to-use software and minimal maintenance provide hassle-free measurements for a wide range of applications and system integration options. Just plug it in and you re ready to go With the new optional pump and display, just power the instrument on, and measurements appear immediately. View real-time measurements, configure graphs, or set up logging options with easy-to-use software. Keep it simple with minimal maintenance Ensure continuous operation and minimize downtime with a user-cleanable optical bench, and no need for factory recalibration. Easily analyze measurements Windows and Mac interface software display real-time concentrations and graphs. Easily set up operational parameters and logging options, and view analyzer diagnostics. 2

Designed for Your Application Ease of use and wide measurement ranges of 0-20,000 ppm for CO2 (LI-830 and LI-850) and 0-60 mmol/mol for H2O (LI-850 only) make the LI-830 and LI-850 Gas Analyzers ideal for a variety of applications. Continuously monitor atmospheric CO2 and H2O in urban or field environments. Trigger exhaust fans or injection of CO2 and/or H2O, to keep concentration levels within a desired range. Alarm outputs can trigger user-supplied relays, to control devices such as pumps or valves, or generate audible alarms. Small size allows for easy integration into other products or systems, while keeping the performance needed for continuous monitoring systems. Common applications include: Growth chambers and greenhouses Atmospheric monitoring Industry/indoor air quality monitoring Building system efficiency (ventilation systems) Process control Bioremediation Atmospheric profiling Leakage monitoring TOC analysis systems Volcanology 5

Advanced Technology for Excellent Performance For nearly 30 years, we ve been designing and building high-speed CO2 analyzers for research applications. We ve improved upon our proven platform, to bring you better analyzers with the performance and reliability you ve come to trust. The LI-830 and LI-850 now feature a longer lasting source further minimizing routine maintenance requirements. Proven Design The analyzers optical path is a thermostatically controlled IR detection system that provides excellent stability. Integrated thermistors and a pressure transducer provide for high accuracy in the concentration calculation over the entire measurement range. The pressure transducer within the gas flow path minimizes variability due to changes in barometric pressure. The optical path is protected by a foam enclosure that helps maintain a controlled thermal environment and protects the bench from mechanical shock and vibrations. Source Gold Plated Optical Path Detector CO2/H2O Filters 6

Display Internal Pump CO2 + H2O Optical Bench Variety of Outputs 8

Flexible to Fit Your Needs Multiple configuration options allow you to select the analyzer that s right for you, without compromise. CO2 + H2O Add water vapor measurements to the standard CO2 measurement (0-20,000 ppm) for expanded applications and increased accuracy of your measurements. Internal Pump An integrated pump provides a constant flow rate. Or, choose an analyzer without a pump and incorporate your own. Analyzer Display Add a display to view real-time gas concentrations, pressure, and temperature readings. Variety of Outputs All analyzer configurations feature a variety of outputs, including: Analog (voltage or current), Digital alarms (TTL or Open Collector), Serial (RS-232 and USB), XML Communications Protocol, and software compatible with Windows and Mac. OEM and System Integration LI-COR can work with you to integrate the LI-830/LI-850 Analyzers into your product or system. Modified configurations are available. Contact LI-COR for more details. 9

Specifications CO2 Measurements Measurement range: 0-20,000 ppm Accuracy: LI-850: Within 1.5% of reading LI-830: Within 3% of reading Calibration drift: Zero drift1: <0.15 ppm/ C Span drift2: <0.03%/ C Total drift at 370 ppm3: <0.4 ppm/ C RMS noise at 370 ppm with 1 sec signal filtering: <1 ppm Sensitivity to water vapor (LI-850 only): <0.1 ppm CO2 / mmol mol -1 H2O Lower limit of detection: 1.5 ppm H2O Measurements (LI-850 only) Measurement range: 0-60 mmol mol -1 Accuracy: Better than 1.5% of reading Calibration drift: Drift at 0 mmol mol -1 : <0.003 mmol mol -1 / C Span drift at 10 mmol mol -1 : <0.03% mmol mol -1 / C Total drift at 10 mmol mol -1 : <0.009 mmol mol -1 / C RMS noise at 10 mmol mol with 1 sec signal filtering: <0.01 mmol mol -1 Sensitivity to CO2: <0.0001 mmol mol -1 H2O / ppm CO2 Pump (optional) Operating temperature range: 5 to 45 C Storage temperature range: -20 to 60 C Operating humidity range: 0 to 80% RH Nominal flow rate: 0.75 liters minute -1 Power consumption: <0.75 W Expected life span: 8,000 hrs in standard conditions with a normal load Display (optional) Dimensions: 6.7 cm corner-to-corner Resolution: 400 x 200 px; monochrome Power consumption: <200 µw Displayed variables: CO2 reading, H2O reading (LI-850 only), optical bench temperature, and pressure. General Output rate: Up to 2 measurements per sec Response time (T90): CO2: <3.5 seconds from 0-375 ppm H2O: <3.5 seconds from 0-21 mmol mol -1 Measurement principle: Non-Dispersive Infrared Traceability: CO2: Traceable gases to WMO standards from 0-3,000 ppm; traceable gases to EPA protocol gases from 3,000-20,000 ppm H2O (LI-850 only): NIST traceable LI-610 Portable Dew Point Generator Pressure compensation range: 50-110 kpa Maximum gas flow rate: 1 liter min -1 Output signals: Two analog voltage (0-2.5 V or 0-5 V) and two current (4-20 ma) Digital outputs: TTL (0-5 V) or Open Collector DAC resolution: 16-bits across user specified range Power requirements: Input voltage: 12-30 VDC After warmup: 0.3 A @ 12 VDC (3.6 W) average During warmup: 1.2 A @ 12 VDC (14 W) maximum Operating temperature range: -20 to 45 C Relative humidity range: 0-95% RH, Non-condensing Dimensions: 22.23 cm W x 15.25 cm D x 7.62 cm H Weight: No pump, no display: 1.0 kg No pump, with display: 1.02 kg With pump, no display: 1.3 kg With pump, with display: 1.32 kg Internal optical cell volume: 14.5 ml 1Zero drift is the change with temperature at 0 concentration. 2Span drift is the residual error after re-zeroing following a temperature change. 3Total drift is the change with temperature without rezeroing or re-spanning. Specifications subject to change without notice. 11

LI-COR Biosciences 4647 Superior Street Lincoln, Nebraska 68504 Phone: +1-402-467-3576 Toll free: 800-447-3576 (USA and Canada) envsales@licor.com envsupport@licor.com www.licor.com/env LI-COR Distributor Network www.licor.com/env/distributors Regional Offices LI-COR Biosciences GmbH Siemensstraße 25A 61352 Bad Homburg Germany Phone: +49 (0) 6172 17 17 771 envsales-gmbh@licor.com LI-COR Biosciences Ltd. St. John s Innovation Centre Cowley Road Cambridge CB4 0WS United Kingdom Phone: +44 (0) 1223 422102 envsales-uk@licor.com LI-COR is an ISO 9001:2015 certified company. LI-COR is a registered trademark of LI-COR, Inc. in the United States and other countries. All other trademarks belong to their respective owners. For patent information, visit www.licor.com/patents. 2018 LI-COR, Inc. 980-17196 Rev.1 02/18 The LI-COR board of directors would like to take this opportunity to return thanks to God for His merciful providence in allowing LI-COR to develop and commercialize products, through the collective effort of dedicated employees, that enable the examination of the wonders of His works. Trust in the LORD with all your heart and do not lean on your own understanding. In all your ways acknowledge Him, and He will make your paths straight. Proverbs 3:5,6