Original instructions PA2200C NO DE ES... 47

Similar documents
Original instructions PAECS NO DE ES

Original instructions PAEC3200 NO DE ES

Original instructions PA3200C NO DE ES

Original instructions PA2500

Original instructions SFS

Original instructions AGI4500/6000

Original instructions AR

Original instructions PA2500

Original instructions PA2500

Original instructions PA2500

AC25. Art.nr:

Original instructions AR

Original instructions. PF Smart... 60

Original instructions. Panther 6-15 kw

Air curtains. For a comfortable indoor climate

Original instructions. Infrared heater IRCF...17

Original instructions. SIRe Basic Quick guide. SIReB

AIR CURTAINS. Air curtains with integrated control panel and remote control. Air curtains without heating, with electric heating or water heating

Air curtains. For a comfortable indoor climate

Fan heater SWT Ceiling mounted fan heater with water heat

Original instructions. Thermoplus PL RU

Comfortline L Series The appreciated, flexible Design Air curtain for mounting up to 4 metres

IHC

Original instructions. Thermoplus

Thermozone AD Corinte

Thermozone SF. Air curtains for vertical mounting in curved doorways

Thermocassette HP SE... 6 GB... 8 NO FR DE FI RU... 18

SIRe Competent Air Curtains Water With quick guide. SIReAC. For wiring diagram, please see p Original instructions

Thermozone ADR 200/300 E/W

SIRe Basic Air Curtains Electric With quick guide. SIReB. For wiring diagram, please see p Original instructions

T-RECESSED RANGE AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

PHV-RECESSED RANGE AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

SIRe Advanced Air Curtains Electric With quick guide. SIReAA GB DE FR For wiring diagram, please see last pages. ES

Original instructions SWX C/D NO DE ES... 26

Installer manual AG-AA10. Air/air heat pump IHB GB AG-AA10-30 AG-AA10-40/50

Elektra F GB NO FR

Thermozone RD. Air curtains for revolving doors

Thermozone AC 300/WAC 300

IMPORTANT INSTRUCTIONS READ & SAVE

IMPORTANT INSTRUCTIONS READ & SAVE

User Instructions for Remote Controlled 2kW Rotisserie Effect Fan Heater Model 1276

IMPORTANT INSTRUCTIONS READ & SAVE

IMPORTANT INSTRUCTIONS READ & SAVE

1500W Black Glass Portable Electric Panel Heater KAHTP20BLKA

Hand Dryer Installation & User Manual

SIRe Advanced Air Curtains Water Ambient, no heat

Air heater/cooler in combination with ground source heat pump

EDGE PATIO HEATER. User Manual. English

Instruction Manual WARNINGS

Original instructions PA

51AKB / 51 AKC OWNER S MANUAL

IMPORTANT INSTRUCTIONS READ & SAVE

Fan Heater SW02 Quiet fan heater for connection to water in small buildings

Silencer Preheater unit Electric post-heating unit Water circulated post-heating unit CO 2 sensor %RH sensor Pressure difference switch LON converter

AIR CURTAIN HX RECESSED RANGE

Topvex SR 09, 11, Topvex TR Compact Air Handling Units

EH0533 Indoor Climate Control

51AKS I S O OWNER S MANUAL

CASSETTE UNIT. Comfort Circle

Topvex SF02-SF12 Air Handling Unit

Installation Instructions & Operating Manual IMPORTANT

EBAC MODEL WM150 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Panel Heater Slim 1.5kw MODEL: NDK15-12K

EH0554 Indoor Climate Control

The green and friendly entrance. Comfort air curtains Model CA 2

Toplock Indoor. Originalbedienungsanleitung

User manual AG-WT10. Indoor unit air/air heat pump UHB GB

Convection Panel Heater

INLINE CENTRIFUGAL FAN. Centro-M OPERATION MANUAL

Mini catalogue air curtains radiant heaters fan heaters convectors thermostats. Comfortable and energy efficient indoor climate.

General Care and Safety Guide

Installation and Operating Manual Drying Cabinet

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

Fan heater Panther Powerful fan heater for large premises

3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

USER S MANUAL NKP. Duct heater for supply air pre-heating with external control

INDUSTRIAL AIR CURTAIN. IndAC 2

PC20-AMFII / PC40-AMF USER MANUAL

AIR CURTAIN T SURFACE MOUNTED RANGE

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

Copperad. Copperad Fan Convectors (November 2005 onwards) Installation, Operation and Maintenance Instructions To be retained by the user

EH kW Panel Heater

Installation & Operating Instructions. Models: Desire, Ignite & Hereford Electric Stoves

CHH - Active Chilled Beam. Halton CHH. Active Chilled Beam

Vacuum Cleaner MC-E3003 MC-E3001. Operating Instructions. Model No.

100cm Chimney Hood GB IE

Electronically controlled instantaneous water heater. MCX: 27300, and models. Installation instructions

Installation and operation manual

OWNER S MANUAL HIGH WALL INVERTER. (English) (BSHVD1S SERIES)

OPERATING INSTRUCTIONS

26 FIREBOX EN RU UA FR

DIGIHEAT IN LINE HEATERS

Installer manual AG-WL10

РУКОВОДСТВО USER ПО MANUAL ЭКСПЛУАТАЦИИ CENTRIFUGAL INLINE FANS VKM / VKMZ / VC SERIES

OPERATING MANUAL ORWAK March 2005 PUBL. NO Edition 4

Danfoss Air Heating Surfaces

The CAB & DAB Air Curtains

QZHW Fan Coil Unit. Key features. Specifications

AC500T, AC1000T, AC1500T, AC2000T

Transcription:

Original instructions PA2200C SE... 20 GB... 27 NO... 33 DE... 40 ES... 47 FR... 54 IT... 61 NL... 68 PL... 75 RU... 82

SE Introduktionssidorna består huvudsakligen av bilder. För översättning av de engelska texter som används, se respektive språksidor. GB The introduction pages consist mainly of pictures. For translation of the English texts used, see the respective language pages. NO Introduksjonssidene består hovedsakelig av bilder. For oversettelse av de engelske tekstene, se de respektive språksidene. FR Les pages de présentation contiennent principalement des images. Pour la traduction des textes en anglais, consultez la page correspondante à la langue souhaitée. DE Die Einleitungsseiten bestehen hauptsächlich aus Bildern. Für die Übersetzung der verwendeten Texte in englischer Sprache, siehe die entsprechenden Sprachseiten. ES Las páginas introductorias contienen básicamente imágenes. Consulte la traducción de los textos en inglés que las acompañan en las páginas del idioma correspondiente. NL De inleidende pagina's bevatten hoofdzakelijk afbeeldingen. Voor een vertaling van de gebruikte Engelse teksten, zie de pagina's van de resp. taal. IT Le pagine introduttive contengono prevalentemente immagini. Per le traduzioni dei testi scritti in inglese, vedere le pagine nelle diverse lingue. PL Początkowe strony zawierają głównie rysunki. Tłumaczenie wykorzystanych tekstów angielskich znajduje się na odpowiednich stronach językowych. RU Страницы в начале Инструкции состоят в основном из рисунков, схем и таблиц. Перевод встречающегося там текста приведен в разделе RU. 2

PA2200C 1026 / 1536 / 2026 20 10 345 90,5 min 500 157 40 165 210 1050 / 1560 / 2050 Cu ø15 53 2 m W/A 157 min 500 min 500 157 184 22 Cu ø15 71 40 E 157 min 500 min 500 157 Fig. 1 Gland ø17,5 Gland ø17,5 ø32,5 ø25,5 ø20,5 Knock-out Knock-out Gland Knock-out ø17,5 Fig. 2 3

A TX20 B C Fig. 3: Open the unit. 4

Minimum distance min 60 Fig. 4 30 mm 60 mm Fig. 5 5

Mounting with wall brackets A B min 500 mm ø8 (3x) 20 ø5 ø10 75 162 210 35 C 33 D PA2210 PA2215 PA2220 2 pcs 2 pcs 3 pcs Fig. 6: Mounting with wall brackets 6

Accessories PA34TR15 PA34TR20 PA2P15 PA2P20 PA2PF15 PA2PF20 PAMLK PA2EF10 PA2EF15 PA2EF20 PAWAK FHDN15 PA2210C, PA2215C, 1 m PA2220C, 1 m PA2210C, PA2215C, 1 m PA2220C, 1 m PA2210C, PA2215C PA2220C PA2200C PA2210C W PA2215C W PA2220C W PA2200C W PA2200C W PA34TR PA2P PA2PF PAMLK PAWAK FHDN15 PA2EF PA2DR PA2DR VOT15 VOT20 VOT25 VKF15LF VKF15NF VKF20 VKF25 VKF32 SD230 BPV10 DN15 DN20 DN25 DN15 DN15 DN20 DN25 DN32 VOT VLSP VKF SD230 BPV10 7

1 Ambient, no heat - PA2200C A Type Output Airflow* 1 Sound power* 2 [db(a)] PA2200C Sound pressure* 3 [db(a)] Voltage motor [V] Amperage motor [A] Length [kw] [m 3 /h] [mm] PA2210CA 0 900/1200 67 42/51 230V 0,45 1050 16 PA2215CA 0 1150/1800 67 40/52 230V 0,5 1560 24 PA2220CA 0 1800/2400 68 43/53 230V 0,9 2050 32 3 Electrical heat - PA2200C E Type Output steps [kw] Airflow* 1 [m 3 /h] t *4 Sound power* 2 [db(a)] Sound Amperage Voltage [V] pressure* 3 motor Amperage [A] [db(a)] [A] (heat) Length Weight [ C] [mm] PA2210CE03 2/3 900/1200 10/7,5 67 42/51 0,45 230V/13 1050 17 PA2210CE05 3,3/5 900/1200 17/12,5 67 42/51 0,45 400V3/7,2 1050 17 PA2210CE051 3,3/5 900/1200 17/12,5 67 42/51 0,45 230V/21,7 1050 17 PA2210CE08 5/8 900/1200 27/20 67 42/51 0,45 400V3/11,5 1050 18 PA2215CE08 4/8 1150/1800 21/13 67 40/52 0,5 400V3/11,5 1560 26 PA2215CE12 8/12 1150/1800 31/20 67 40/52 0,5 400V3/17,3 1560 28 PA2220CE10 5/10 1800/2400 17/12,5 69 43/53 0,9 400V3/14,4 2050 34 PA2220CE16 10/16 1800/2400 27/20 69 43/53 0,9 400V3/23,1 2050 36 2 Water heat - PA2200C W Voltage motor: 230V [kg] Weight [kg] Type Output* 5 Airflow* 1 t *4,5 Water volume [l] Sound power* 2 [db(a)] Sound pressure* 3 [db(a)] Amperage motor [A] Length [kw] [m 3 /h] [ C] [mm] PA2210CW 7 700/1200 21/17 0,38 67 39/52 0,4 1050 17 PA2215CW 11 1000/1750 23/18 0,81 68 37/53 0,5 1560 26 PA2220CW 14 1400/2400 22/18 0,74 68 40/53 0,8 2050 35 * 1 ) Lowest/highest airflow of totally 3 fan steps. * 2 ) Sound power (L WA ) measurements according to ISO 27327-2: 2014, Installation type E. * 3 ) Sound pressure (L pa ). Conditions: Distance to the unit 5 metres. Directional factor: 2. Equivalent absorption area: 200 m². At lowest/highest airflow. * 4 ) t = temperature rise of passing air at maximum heat output and lowest/highest airflow. * 5 ) Applicable at water temperature 80/60 C, air temperature, in +18 C. Protection class for units with electrical heating: IP20. Protection class for units without heating and units with water heating: IP21. CE compliant. Weight 3 Electrical heat 230V3 - PA2200C E Type Output Airflow* 1 t *4 Sound Sound Amp. Voltage Amp. Length Weight steps power* 2 pressure* 3 motor heat heat [kw] [m 3 /h] [ C] [db(a)] [db(a)] [A] [V] [A] [mm] [kg] PA2210CE05YD 2,5/5 900/1200 17/12,5 67 42/51 0,45 230V3/400V3N 7,2/12,6 1050 17 PA2215CE08YD 4/8 1150/1800 21/13 67 40/52 0,5 230V3/400V3N 11,5/20,1 1560 26 PA2220CE10YD 5/10 1800/2400 17/12,5 69 43/53 0,9 230V3/400V3N 14,4/25,1 2050 34 Type Mid [mf] C2 Low C2 Run [mf] [mf] Type Mid [mf] C2 Low C2 Run [mf] [mf] [kg] PA2210CA 6 5 3 PA2215CA 8 6 4 PA2220CA 6 5 3 PA2210CE03 6 5 3 PA2210CE05 6 5 3 PA2210CE08 6 5 3 PA2215CE08 8 6 4 PA2215CE12 8 6 4 PA2220CE10 6 5 3 PA2220CE16 6 5 3 PA2210CW 7 5 3 PA2215CW 8 6 4 PA2220CW 7 5 3 PA2210CE05YD 6 5 3 PA2215CE08YD 8 6 4 PA2220CE10YD 6 5 3 8

PA2210CA / PA2215CA / PA2220CA PA2210CA PA2215CA PA2220CA Only 2 m version Left motor Right motor 9

PA2210CE03 / PA2210CE05 L PE N L PE N on/off 1 2 0-10V HEAT ALARM WATER On Off 230V 5A INTERNAL SENSOR L2 L1 PE L N IR NH1H2 16A N F1 F2 F3 5A x 3 0-10V C C PA2210CE03 PA2210CE05 M Over heat cut-out Mid L3 400V 3N L3 L2 L1 PE L N 2210CE03 C2 Lo 2210CE05 C3 Run 10

PA2210CE051 L PE N L PE N on/off 1 2 0-10V HEAT ALARM WATER On Off 5A 16A 230V 5A x 3 INTERNAL SENSOR L2 L1 PE L N L3 IR NH1H2 N F1 F2 F3 0-10V C M Over heat cut-out Run Mid Lo 2210CE051 C PA2210CE051 11

PA2215CE08 / PA2220CE10 400V 3N L2 L1 PE L N L3 N on/off 1 2 On Off L PE N L PE 5A 16A 5A x 3 0-10V HEAT ALARM WATER INTERNAL SENSOR IR NH1H2 N F1 F2 F3 0-10V C C2 Over heat cut-out C PA2215CE08 PA2220CE10 M Over heat cut-out C Only 2 m version M Right motor Mid C Left motor C4 C2 Lo C3 C3 Run 400V3 L3 L2 L1 PE Mid C2 Lo C3 Run 12

PA2210CE08 / PA2215CE12 / PA2220CE16 PA2200C 400V 3N L2 L1 PE L N L3 N on/off 1 2 On Off L PE N L PE 5A 16A 5A x 3 0-10V HEAT ALARM WATER INTERNAL SENSOR IR NH1H2 N F1 F2 F3 0-10V C C2 = high power = low power C2 Over heat cut-out C PA2210CE08 PA2215CE12 PA2220CE16 M Over heat cut-out C C4 = high power C4 C3 = low power Only 2 m version M Right motor Mid C Left motor C2 Lo C3 400V3 L3L2 L1 PE C3 Run Mid C2 Lo C3 Run 13

PA2210CW / PA2215CW / PA2220CW on/off 1 2 On L PE N L PE Off N 5A 16A 5A x 3 INTERNAL SENSOR IR 0-10V HEAT ALARM WATER NH1H2 N F1 F2 F3 0-10V C PA2210CW PA2215CW PA2220CW M M Right motor C Left motor Mid Only 2 m version C2 Lo C3 Run Mid C2 Lo C3 Run 14

PA2210CE05YD / PA2215CE08YD 230V 3 N on/off 1 2 On Off L PE N L PE 5A 16A 5A x 3 L2 L1 PE L N 0-10V HEAT ALARM WATER INTERNAL SENSOR IR NH1H2 N F1 F2 F3 0-10V C C2 Over heat cut-out Over heat cut-out L3 L3 400V 3N L2 L1 PE L N C C PA2210CE05YD PA2215CE08YD 400V 3 230V 3 c2 b2 a2 c1 b1 a1 c2 b2 a2 c1 b1 a1 M Right motor Mid C2 Lo C3 Run 15

PA2220CE10YD L PE N L PE N on/off 1 2 C C2 Over heat cut-out L2 L1 PE L N L3 400V 3N C (230V 3) c2 b2 a2 c1 b1 a1 400V 3 c2 b2 a2 c1 b1 a1 PA2220CE10YD C4 C3 400V3 L3 L2 L1 PE (230V3) L3 0-10V DOOR AFTER WATER L2 L1 PE (230V 3) c2 b2 a2 c1 b1 a1 400V 3 c2 b2 a2 c1 b1 a1 M Over heat cut-out L3 (230V 3) L2 L1 PE L N C M Right motor On Off C Left motor Mid C2 Lo C3 Run Mid C2 Lo C3 Run 5A 16A 5A x 3 INTERNAL SENSOR IR NH1H2 N F1 F2 F3 0-10V 16

M PA2200C PAMLK, motor alarm card L PE N L PE N on/off 1 2 NF1F2F3 OUT C PAMLK Right motor Run Mid Lo NC C NO Motor alarm (pot. free contact) On Off C M Left motor Run Only 2 m version Mid Lo 5A 16A 5A x 3 INTERNAL SENSOR IR 0-10V HEAT ALARM WATER NH1H2 N F1 F2 F3 0-10V On Off C M 17

Output charts water PA2200C Supply water temperature:110 C Room temperature: +18 C Outlet air temperature: +35 C* 1 Water temperature: 110/80 C Room temperature: +18 C Type Fan Airflow Output Return Water Pressure Output * 2 Outlet Water Pressure position water temp. flow drop air temp. flow drop [m 3 /h] [kw] [ C] [l/s] [kpa] [kw] [ C] [l/s] [kpa] PA2210CW max 1200 6,9 53,7 0,03 1,1 10,4 43,5 0,09 6,9 min 700 4,0 45,4 0,02 0,4 7,6 50,0 0,06 3,9 PA2215CW max 1750 10,4 48,1 0,04 1,1 16,7 45,3 0,14 9,2 min 1000 5,8 39,8 0,02 0,3 11,7 52,3 0,10 4,8 PA2220CW max 2400 13,9 51,1 0,06 1,0 21,7 44,6 0,18 7,5 min 1400 8,1 43,4 0,03 0,3 15,8 51,2 0,13 4,2 Supply water temperature:90 C Room temperature: +18 C Outlet air temperature: +35 C* 1 Water temperature: 90/70 C Room temperature: +18 C Type Fan Airflow Output Return Water Pressure Output * 2 Outlet Water Pressure position water temp. flow drop air temp. flow drop [m 3 /h] [kw] [ C] [l/s] [kpa] [kw] [ C] [l/s] [kpa] PA2210CW max 1200 6,9 57,8 0,05 3,1 8,5 38,8 0,10 10,2 min 700 4,0 48,1 0,02 0,8 6,2 44,1 0,08 5,8 PA2215CW max 1750 10,4 53,1 0,07 2,9 13,6 40,2 0,17 13,5 min 1000 5,8 43,3 0,03 0,7 9,5 45,9 0,12 7,0 PA2220CW max 2400 13,9 55,4 0,10 2,7 17,7 39,7 0,22 11,1 min 1400 8,1 46,2 0,05 0,7 12,8 45,0 0,16 6,3 Supply water temperature:80 C Room temperature: +18 C Outlet air temperature: +35 C* 1 Water temperature: 80/60 C Room temperature: +18 C Type Fan Airflow Output Return Water Pressure Output * 2 Outlet Water Pressure position water temp. flow drop air temp. flow drop [m 3 /h] [kw] [ C] [l/s] [kpa] [kw] [ C] [l/s] [kpa] PA2210CW max 1200 6,9 60,2 0,09 7,3 6,9 35,0 0,08 7,2 min 700 4,0 49,7 0,03 1,4 5,0 39,2 0,06 4,1 PA2215CW max 1750 10,4 56,1 0,11 6,2 11,1 36,2 0,14 9,6 min 1000 5,8 45,5 0,04 1,2 7,8 40,8 0,10 5,1 PA2220CW max 2400 13,9 57,9 0,14 6,2 14,4 35,7 0,18 7,9 min 1400 8,1 47,9 0,06 1,2 10,5 40,0 0,13 4,5 Supply water temperature:70 C Room temperature: +18 C Outlet air temperature: +35 C* 1 Water temperature: 70/50 C Room temperature: +18 C Type Fan Airflow Output Return Water Pressure Output * 2 Outlet Water Pressure position water temp. flow drop air temp. flow drop [m 3 /h] [kw] [ C] [l/s] [kpa] [kw] [ C] [l/s] [kpa] PA2210CW max 1200 6,9 62,5 0,23 43,1 5,3 31,0 0,07 4,6 min 700 4,0 51,7 0,05 3,3 3,9 34,3 0,05 2,7 PA2215CW max 1750 10,4 59,3 0,24 26,7 8,7 32,2 0,11 6,3 min 1000 5,8 48,0 0,06 2,6 6,0 35,8 0,07 3,3 PA2220CW max 2400 13,9 60,5 0,35 28,5 11,1 31,6 0,14 5,1 min 1400 8,1 50,0 0,10 2,9 8,1 35,0 0,10 2,9 * 1 ) Recommended outlet air temperature for good comfort and optimized output. * 2 ) Nominal output at given supply and return water temperature. 18

Output charts water Type Fan position Airflow PA2200C Supply water temperature: 60 C Room temperature: +18 C Outlet air temperature: +32 C Output Return Water Pressure water temp. flow drop [kw] [ C] [l/s] [kpa] Water temperature: 60/40 C Room temperature: +18 C Output * 2 Outlet Water air temp. flow [ C] [l/s] [m 3 /h] [kw] PA2210CW max 1200 5,7 55,0 0,28 64,4 3,7 27,0 0,05 2,5 min 700 3,3 46,3 0,06 4,0 2,7 29,3 0,03 1,4 PA2215CW max 1750 8,6 52,5 0,28 36,5 6,1 28,0 0,07 3,6 min 1000 4,8 43,3 0,07 3,1 4,3 30,6 0,05 1,9 PA2220CW max 2400 11,4 53,4 0,42 39,7 7,8 27,5 0,09 2,8 min 1400 6,7 44,9 0,11 3,5 5,6 29,8 0,07 1,6 Pressure drop [kpa] Type Fan position Airflow Supply water temperature: 55 C Room temperature: +18 C Outlet air temperature: +29 C Output Return Water Pressure water temp. flow drop [kw] [ C] [l/s] [kpa] Water temperature: 55/35 C Room temperature: +18 C Output * 2 Outlet Water air temp. flow [ C] [l/s] [m 3 /h] [kw] PA2210CW max 1200 4,5 46,5 0,13 16,3 2,8 24,9 0,03 1,6 min 700 2,6 40,0 0,04 2,3 2,0 26,5 0,02 0,9 PA2215CW max 1750 6,7 44,2 0,15 12,5 4,9 25,9 0,06 2,4 min 1000 3,7 37,4 0,05 1,9 3,4 27,9 0,04 1,3 PA2220CW max 2400 9,0 45,2 0,22 12,8 6,0 25,4 0,07 1,8 min 1400 5,2 38,9 0,08 2,1 4,3 27,1 0,05 1,0 Pressure drop [kpa] * 1 ) Recommended outlet air temperature for good comfort and optimized output. * 2 ) Nominal output at given supply and return water temperature. See www.frico.se for additional calculations. 19

GB Assembly and operating instructions General Instructions Read these instructions carefully before installation and use. Keep this manual for future reference. The product may only be used as set out in the assembly and operating instructions. The guarantee is only valid if the product is used in the manner intended and in accordance with the instructions. Application area The PA2200C air curtain unit is supplied without heating, with electrical heating or hot water heating. The PA2200C is a compact air curtain, suitable for most small entrances up to 2.2 metres in height. The air curtain has an integrated control system and can be remotely controlled. Protection class for units with electrical heating: IP20. Protection class for units without heating and units with water heating: IP21. Operation Air is drawn in at the top of the unit and blown out downwards so that it shields the door opening and minimizes heat loss. To achieve the optimum curtain effect the unit must extend the full width of the door opening. The grille for directing exhaust air is adjustable and is normally angled outwards to achieve the best protection against incoming air. The efficiency of the air curtain depends on the air temperature, pressure differences across the doorway and any wind pressure. NOTE! Negative pressure in the building considerably reduces the efficiency of the air curtain. The ventilation should therefore be balanced. Mounting The air curtain unit is installed horizontally with the supply air grille facing downwards as close to the door as possible. Minimum distance from outlet to floor for electrically heated units is 1800 mm. For other minimum distances, see fig. 4. Mounting with wall brackets (fig. 6) 1. Mount the brackets on the wall, see fig.6a and dimension drawing fig.1. If the wall is uneven the brackets must be compensated for this. 2. Hook on the unit at the lower edge of the brackets. (Fig.6B) 3. Bend the top of the console over the the unit and slide the units screws along the rail into the slots on the consoles. (Fig.6C) When the bracket is bent once, it must be replaced if bent back more than 45. 4. Lock the nuts against the brackets. (Fig.6D) Horizontal mounting on the ceiling Threaded rods, hanging brackets and ceiling mounting brackets for ceiling mounting are available as accessories, see accessories pages and separate manuals. Electrical installation The installation, which should be preceded by an omnipolar switch with a contact separation of at least 3 mm, should only be wired by a competent electrician and in accordance with the latest edition of IEE wiring regulations. The control system is pre-installed in the air curtain. Unit without heating Connected via the built-in control board with 1,5 m cord and plug. Unit with water heating Connected via the built-in control board with 1,5 m cord and plug. Unit with electrical heating The electrical connection is made on the top of the unit. See Fig.2. The 3 kw unit is connected via the integrated control card using a 1,5 m cable and plug. Other units are intended for permanent installation. Control (230V) and power supply for heat (400V3) should be connected to a terminal block in the terminal box. 2-metre and longer units require dual power supplies. The largest cable diameter for the terminal block is 16 mm². The cable glands used must meet the protection class requirements. In 27

GB PA2200C the distribution board it is to be indicated that the air curtains can be supplied from more than one connection. See wiring diagrams. Type Output Voltage Minimum area* [kw] [V] [mm 2 ] Control 0 230V 1,5 PA2210CE05 5 400V3 1,5 PA2210CE051 5 230V 6 PA2215CE08 8 400V3 2,5 PA2215CE12 12 400V3 4 PA2220CE10 10 400V3 2,5 PA2220CE16 16 400V3 6 *) Dimensioning of external wiring shall comply with applicable regulations and local deviations may occur. Start-up (E) When the unit is used for the first time or after a long period of disuse, smoke or odour may result from dust or dirt that has collected on the element. This is completely normal and disappears after a short time. Connecting the water coil (W) The installation must be carried out by an authorised installer. The water coil has copper tubes with aluminium fins and is suitable for connection to a closed water heating system. The heating coil must not be connected to a mains pressure water system or an open water system. Note that the unit shall be preceded by a regulating valve, see Frico valve kit. The water coil is connected on the upper side of the unit with ø15 mm smooth copper pipe with a suitable coupling or soldering. The connections to the heating coil must be equipped with shut off valves to allow problem free removal. Water coil is equipped with a drain valve. A vent valve should be connected at a high point in the pipe system. Air valves are not included. NOTE: Care must be taken when connecting the pipes. Use a wrench or similar to hold the air curtain connections to prevent straining of the pipes and subsequent water leakage during connection to water supply pipe-work. Adjustment of the air curtain and air flow The direction and speed of the air flow should be adjusted considering the load on the opening. Pressure forces affect the air stream and make it bend inwards into the premises (when the premises are heated and the outdoor air is cold). The air stream should therefore be directed outwards to withstand the load. Generally speaking, the higher the load, the greater the angle that is needed. Basic setting fan speed The fan speed when the door is open is set using the control. Note that the air flow direction and fan speed may need fine adjustment depending on the loading of the door. Filter (W) The water coil is protected against dirt and blockage by an internal air filter which covers the coil face. In environments where the filter needs cleaning often, it is advisable to use an external intake filter (see accessories pages), which provides an easier maintenance, since the unit does not need to be opened. When an external filter is used, the internal filter is removed. Service, repairs and maintenance For all service, repair and maintenance first carry out the following: 1. Disconnect the power supply. 2. The front hatch is removed by removing the screws on the top of the unit and then detach the bent edge at the bottom. (Fig.3) 3. After the service, repair and maintenance reattach the front hatch. Place the hatch at the lower edge with the bent edge and fasten on top with screws. 28

GB Maintenance Unit with water heating The appliance filter should be cleaned regularly to ensure the air curtain effect and the heat emission from the device. How often depends on local circumstances. A clogged filter is not a risk, but the appliance function can fail. 1. Disconnect the power supply. 2. The front hatch is removed by removing the screws on the top of the unit and then detach the bent edge at the bottom. (Fig.3) 3. Remove the filter and vacuum clean or wash it. If the filter is clogged or damaged, it may need to be changed. All units: Since fan motors and other components are maintenance free, no maintenance other than cleaning is necessary. The level of cleaning can vary depending on local conditions. Undertake cleaning at least twice a year. Inlet and exhaust grilles, impeller and elements can be vacuum cleaned or wiped using a damp cloth. Use a brush when vacuuming to prevent damaging sensitive parts. Avoid the use of strong alkaline or acidic cleaning agents. Overheating The air curtain unit with electric heater is equipped with an overheat protector. If it is deployed due to overheating, reset as follows: 1. Disconnect the electricity with the fully isolated switch. 2. Determine the cause of overheating and rectify the fault. 3. Remove the front hatch. 4. Press the red button located inside the air curtain unit, at the inner gable of the terminal box. 5. Reattach the front hatch and connect the unit again. All motors are equipped with an integral thermal safety cut-out. This will operate, stopping the air curtain should the motor temperature rise too high. The cut-out will automatically reset when the motor temperature has returned to within the motor s operating limits. Temperature control See control pages. Replacing motor or impeller 1. Remove the front. 2. Remove gable end. 3. Remove the screw between motor and fan. 4. Disconnect the cables to the motor. 5. Remove the screws securing the motor and lift it out together with the impeller. 6. Install the new motor and/or the new impeller as above in reverse order. Replacing heating elements/heating package (E) 1. Mark and disconnect the cables to the heating elements/package 2. Remove the mounting screws securing the heating elements/package in the unit and lift the heaging elements/package out. 3. Install the new heating elements/package in reverse order to the above. Replacing the water coil (W) 1. Shut off the water supply to the unit. 2. Disconnect the connections to the water coil. 3. Remove the mounting screws securing the coil in the unit and lift the coil out. 4. Install the new coil in reverse order to the above. Draining the water coil (W) The drain valve is on the underside of the coil on the connector side. It can be accessed via the front hatch. Trouble shooting If the fans are not working or do not blow properly, check the following: The functions and settings of the built-in control system. That the intake grille/filter is not dirty. If there is no heat, check the following: The functions, internal sensor and settings of the built-in control system. 29

GB PA2200C For units with electrical heating, also check the following: Power supply to electric heater coil; check fuses and circuit-breaker (if any). That the overheat protection for the motors has not been deployed. For units with water coil, also check the following: That the water coil is air free. That there is enough water flow. That incoming water is heated enough. If the fault cannot be rectified, please contact a qualified service technician. Residual current circuit breaker (E) When the installation is protected by means of a residual current circuit breaker, which trips when the appliance is connected, this may be due to moisture in the heating element. When an appliance containing a heater element has not been used for a long period or stored in a damp environment, moisture can enter the element. This should not be seen as a fault, but is simply rectified by connecting the appliance to the main supply via a socket without a safety cut-out, so that the moisture can be eliminated from the element. The drying time can vary from a few hours to a few days. As a preventive measure, the unit should occasionally be run for a short time when it is not being used for extended periods of time. Safety For all installations of electrically heated products should a residual current circuit breaker 300 ma for fire protection be used. Keep the areas around the air intake and exhaust grilles free from possible obstructions! The unit may have hot surfaces during operation and when cooling down! The unit must not be fully or partially covered with clothing, or similar materials, as overheating can result in a fire risk! (E) This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. 30

GB Control The air curtain has an integrated control system and can be remotely controlled. 230V Actuator SD230 (remove the quick connector) PA2DR (accessory) External on/off Eg time switch. External potential free closure = off ON OFF ON 1 2 3 4 1 3 ON 1 2 3 4 2 Factory setting dip-switches - Unit without heating or with electrical heating Dip-switch 3 is used for PA2DR (optional). Factory setting dip-switches - Unit with water heating Dip-switch 3 is used for PA2DR (optional). 31

GB PA2200C Fan step 1/2/3 Heat step Electric: Half/full power Water: On/off (1 LED) On/off Control panel - Unit with electrical heating or water heating 20 C 3 2 Fan step 1/2/3 On/off Control panel - Unit without heating 1 Remote control - on/off, fan steps and heating steps Functional test Functional test is started using the remote control. Push and in 5 seconds Fan and heatings steps are tested in 10-second intervals which is indicated by lighted LEDs. When the test is completed, all LEDs will flash for 30 seconds. Temperature control If the temperature exceeds 50 C, the fan runs at full speed for 2 minutes to vent out the heat, if the temperature rises above 50 C again during the following 5 minutes overheating alarm is deployed. The red LEDs flash and all the buttons are locked. 1. Disconnect the electricity with the fully isolated switch. 2. Determine the cause of overheating and rectify the fault. 3. Connect the unit again. 32

Main office Frico AB Tel: +46 31 336 86 00 Box 102 SE-433 22 Partille mailbox@frico.se Sweden www.frico.se For latest updated information and information about your local contact: www.frico.se Art.no 208873, 2017-08-30, HH