Emergency shutdown systems. Procedures for bypassing ESD s

Similar documents
POSITION PAPER ON WATER MIST FOR FIRE FIGHTING APPLICATIONS

NEBOSH International Technical Certificate in Oil and Gas Operational Safety

SEMICONDUCTOR FABRICATION FACILITIES

SEMICONDUCTOR FABRICATION FACILITIES

SEMICONDUCTOR FABRICATION FACILITIES

SEMICONDUCTOR FABRICATION FACILITIES

WATER MIST CONVENTION AND EXHIBITION

FUNCTIONAL SAFETY IN FIRE PROTECTION SYSTEM E-BOOK

Element C3.4 Fire Fighting Equipment

The Science Behind Water Mist Protection of Typical Building Hazards

Safety Instrumented Systems

Savard Labor & Marine Staffing, Inc. Fire Prevention Program Rev3/14

International Safety Guide Chapter 30 for Inland Navigation Tank-barges and Terminals. Chapter 30 FIRE-FIGHTING

Design & Use of Ground Based Pumps Guidance Document

Explosion Protection Engineering Principles

RIM SEAL SYSTEMS E-BOOK

A. General Safety LAB/ROOM: INSPECTED BY: DATE:

Fire protection on chemical manufacturing sites

HKIE CPD Training Course (II) 23, 25 June and 7, 9 July 2009

Fireward Fixed Fire Fighting System. For Open Areas & Enclosed Risks fireward.co.uk

APPLICATION BULLETIN COMBUSTION TURBINE FACILITIES. Overview

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

Fire Hazard Identification Checklist 1

Proof Testing Level Instruments

Application of BS 8489 to the Protection of Generator Enclosures. IWMA, BRE 22 nd March 2017 Dr Tim Nichols CPhys FIFireE

SAFETY MANUAL. Multispectrum IR Flame Detector X3301

Fire Hazard Identification Checklist 1

SAFETY MANUAL. Electrochemical Gas Detector GT3000 Series Includes Transmitter (GTX) with H 2 S or O 2 Sensor Module (GTS)

Water Mist Fire Suppression

Fire Suppression. Water-Mist : A Revolutionary Green Technology in. - by Nimit Sheth TALL, SMART, SAFE BUILDINGS FOR SMART CITIES.

MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle.

NIPSCO Michigan City Generating Station

Martin Huber 26September 2017 F&G SOLUTIONS FOR THE PROCESS INDUSTRY

Fire is No Accident Fire is No Accident It can be prevented.

MODULE 2. Water-Based Suppression System Basics

Amerex Fire Suppression Systems. Because Operators and the Environment are NOT Disposable Quality is Behind the Diamond.

SAFETY MANUAL. PointWatch Eclipse Infrared Hydrocarbon Gas Detector Safety Certified Model PIRECL

SAFETY MANUAL. X2200 UV, X9800 IR, X5200 UVIR SIL 2 Certified Flame Detectors

Essentials of Fire Fighting 6 th Edition Firefighter I

An Overview of Extinguishing Systems for Computer Equipment

Fire and Gas Detection and Mitigation Systems

Saving lives with coatings

2008 NYC Fire Code. New Laboratory Standards. Operational & Maintenance Provisions effective July 2008

SAFETY MANUAL. Intelligent Sensors for H 2 S Gas Applications

The Protection of Machinery Spaces by means of the Local Application of Water Mist. Dr. Tim R. Nichols CPhys FIFireE

IMO. Resolution A.951(23) Adopted on 5 December 2003 (Agenda item 17) IMPROVED GUIDELINES FOR MARINE PORTABLE FIRE EXTINGUISHERS

Fire protection for buildings

2010 FIRE CODE OF NEW YORK STATE

MB05. RESPOND TO EMERGENCIES BASIC KNOWLEDGE OF EMERGENCY PROCEDURES, INCLUDING EMERGENCY SHUTDOWN

Interaction of Water Extinguishing Systems and Smoke and Heat Exhaust Ventilation Systems (SHEVS)

Highly Protected Risks in Power Generation Stewart Kidd outlines the issues to consider when installing active fire suppression in power stations THE

S12 Fire Safety Risk Assessment H&SFS01-1 / 9

SERT FIRE ELEMENTS & HAZ MAT

DIRECTIVE NO: D-B

Committee Input No. 60-NFPA [ Sections , ]

Fire Safety. Version 1.0

FIRE SAFETY PLAN FOR RICHMOND, B.C.

KRISHNAMURTI FOUNDATION TRUST FIRE SAFETY POLICY. Last Review Date 30 June Next review date 30 August Health and Safety Officer

I wish I could protect my business with the most suitable Water Mist solution to fit my needs.

Solutions. Fire risk under control in welding fume extraction systems

WATER MIST FIRE PROTECTION SYSTEMS FOR INDUSTRIAL CABLE TUNNELS AND TURBINE HALLS

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT HORSEFAIR HOUSE

This policy applies to all Hot Work jobs performed on the Calhoun mill property by AbitibiAbitibiBowater employees.

Branch Solution Wood based panel plants. Fire protection solutions for wood based panel plants

2.07 Permit Application Checklist for Diesel Generators, Diesel Fire Pumps, and Fuel Tanks Serving Generators and Fire Pumps (2016)

Title: Fire Protection Effective Date: 7/1/2013 Control Number: THG_0039 Revision Number: 1 Date: 10/23/2015 Annual Review Completed: 5/13/2015

NFPA 33 Standard for Spray Applica4on Using Flammable or Combus4ble Materials

ISHRAE. Guideline document to ISO Version 1 Feb Indian Society of Heating, Refrigerating and Air Conditioning Engineers

Bowties in process safety auditing

Dangerous Goods Logistics

7 Fire Protection Systems Synopsis

WAS STARTED BY CARLOS BAHAMONDES MASAFIERRO

CHAPTER 61G15-32 RESPONSIBILITY RULES OF PROFESSIONAL ENGINEERS CONCERNING THE DESIGN OF FIRE PROTECTION SYSTEMS

NITOL INSURANCE COMPANY LIMITED

Water Spray Systems: NFPA 15

Facility Safety Rules Hazard Communication Emergency Procedures Fire Safety. Safety Orientation

Watermist Fire Protection of Plant Rooms

LABORATORY SAFETY SERIES: Flammables & Explosives

FIRE PROTECTION TECHNOLOGY Solutions never thought of before

Hot Work Permit. Can this job be avoided? Is there a safer alternative? Permit No.:

Making sense of risk Risk engineering. Metalworking operations

& Fire Extinguisher Training

FUNCTIONAL SAFETY MANUAL

White Paper. The Victaulic Vortex Fire Suppression System Fire Suppression for Electrical and Electronic Applications

Safe working with flammable substances

Correctly Classifying and Determining Fire Protection Requirements for High- Hazard Group H Occupancies in New York State (2010 codes)

LOW EXPANSION FOAM FIRE EXTINGUISHING SYSTEM

Numerical Standards Listing

Fire Safety Handbook

ADIPEC 2013 Technical Conference Manuscript

THE ALLIANCE FOR BANGLADESH WORKER SAFETY BOILER SAFETY

RISK ENGINEERING GUIDELINE.

Contents. xiii. 4. PHYSICAL PROPERTIES OF HYDROCARBONS General Alkene Series... 28

Fire protection solutions for ships and offshore facilities BRANCH SOLUTION

DSEAR - Requirements

LOPA. DR. AA Process Control and Safety Group

Building Standards Division. Whisky Maturation Warehouses Storage Buildings (Class 1) Automatic Fire Suppression Systems

The Next Generation of Foam Fire Suppression. Automatic CAF Fire hose reel system FEATURES

Using CFD to Analyze Gas Detector Placement in Process Facilities

General Industry Safety and Health Checklist Guidelines. Building and Premises. Loss Control Bulletin

Transcription:

HYDROCARBON PROCESS SAFETY 2 - ELEMENT 3 - UNIT IOG1 Emergency shutdown systems Emergency shutdown systems (ESD s) are intended to minimise the consequences of emergency situations, for example, the uncontrolled release/loss of containment of hydrocarbons, or the outbreak of fire in hydrocarbon areas. Generally designed with a high safety integrity level (SIL) typical actions of an ESD include: Shutdown of a system, or part of a system. Isolate hydrocarbon inventories. Stop hydrocarbon flow. Prevent escalation of an incident. Depressure/blowdown. For shutdown valves used in safety instrumented systems it is essential to know that the valve is capable of providing the required level of safety performance and that the valve will operate on demand. Figure 3-8: Emergency shut down valve. Source: Wikimedia. The required level of performance is dictated by the safety integrity level (SIL). In order to adhere to this level of performance it is necessary to test the valve. There are two types of testing methods available: A proof test: a manual test that will determine whether the valve is as good as new, by testing for all possible failure modes. This may require a system shutdown (unless by pass facilities are provided). A diagnostic test: An online test that will detect some of the possible failure modes of the valve (for example, a partial stroke test). Procedures for bypassing ESD s Occasionally, ESD s will need to be bypassed or overridden (for example, for emergency maintenance work). These operations must be very closely controlled, and subject to a written procedure (this may be included in the management of change procedures, as a temporary change). Authorised by a competent person (often a Plant Manager), and subject to justification and risk assessment, alternative means of control in the event of an emergency should be considered. The bypass arrangement should be applied for the shortest possible period of time. The details of bypass arrangements should be entered into a logbook and communicated to all relevant parties (for example, operations, maintenance staff and supervision). This is critically important should the bypass be in place during a shift hand over. FIRE AND GAS CONTROLS Oil and Gas installations should be designed to be safe. However there will always be residual risks. Layers of protection need to be designed in, to detect any anomalies that the process control system hasn t taken care of. These additional layers should make the process safe. The fire and gas detection system provides an extra layer of protection to mitigate the consequences when the other safeguarding layers have not been sufficient. The gas detection system can detect a discharge of combustible or toxic gas and take action to minimise the leak and prevent it turning into a fire or explosion. If a fire should result, systems can be attached to extinguish the fire and protect other areas from the actions of the fire. The same system, usually with different detectors and principles, can be used to detect toxic gases, give warning to personnel and provide the possibility of taking automatic shutdown actions. SAFETY INTEGRITY LEVELS FOR INSTRUMENTATION Safety integrity level (SIL) is a statistical representation of the reliability of safety instrument systems. There are four categories, namely SILs 1, 2, 3 and 4, SIL 1 being the least dependable and SIL 4 being the most dependable. It is defined as the probability of the safety instrument system (SIS) to fail on demand (PFD). A process demand occurs whenever the process reaches the trip condition and causes the SIS to take action. Consider a tank filling with a process fluid. If the tank is full, the SIS comes into play as the trip conditions are reached. The SIS prevents the tank from overflowing. The number of times this occurs is known as the incident frequency. Consider an SIL 1 installation, which has a maximum probability level of 1 in 10. This means for every 10 times the SIS is activated as a result of a high tank level trip, the safety function (for example, the dump valve opens lowering the level) could be expected to work nine times. The other one time the safety function would not work and the tank would overflow. RMS 57

UNIT IOG1 - ELEMENT 4 - FIRE PROTECTION AND EMERGENCY RESPONSE SPRINKLER SYSTEMS Automatic sprinkler systems are used more than any other fixed fire protection system. The purpose of an automatic sprinkler system is to detect the fire, extinguish or control the fire and to raise the alarm. The structure/area to be protected is covered by a grid of pipes with sprinkler heads fitted into them at regular intervals. Pumped water (from a source such as a tank or seawater) fills the pipes. Each sprinkler head will open when it reaches a specific temperature and spray water on to a fire. The hot gases from a fire are usually enough to make it operate. Figure 4-9: Sprinkler head with frangible bulb. Source: J.Hind. Only the sprinklers over the fire open. The others remain closed. This limits any damage to areas where there is no fire and reduces the amount of water needed. At the point where the water enters the sprinkler system there is a valve. This can be used to shut off the system for maintenance. For safety reasons it is kept locked open and only authorised persons should be able to close it. DELUGE SYSTEMS Deluge water spray systems are similar to sprinkler systems, except all nozzles are open and will discharge together when the system is activated. These systems are used where rapid fire spread is a concern, as they provide a simultaneous application of water over the entire hazard. Water is not present in the piping until the system operates. To prevent the water supply pressure from forcing water into the piping, a deluge valve is used in the water supply connection, which is a mechanically latched valve. It is a non-resetting valve, and stays open once tripped. Figure 4-10: Deluge water spray system. Source: J.Hind. The deluge valve must be opened as signalled by a fire alarm system. The type of fire alarm initiating device is selected mainly based on the hazard. The initiation device signals the fire alarm panel, which in turn signals the deluge valve to open. Activation can also be manual. Deluge systems can provide rapid cooling, reducing available oxygen. In addition, there is also a reduction in the amount of radiant heat that may be transmitted to nearby structures or vessels. WATER MIST SYSTEMS Water mist is a fine spray with 99 percent of water volume contained in water droplets less than one millimetre (1,000 microns) in diameter. Water divided into very fine droplets creates a greater surface area than standard droplets emitted from sprinkler system heads. Water mist system droplets can be 20 times smaller and have a surface area 400 times greater than sprinkler system water droplets. This enhanced area allows more of the water to absorb the heat from the fire. Steam generated during the cooling process, provides an inert blanket, which has the effect of also excluding oxygen from the fire. Figure 4-11: Water mist sprinkler head. Source: J.Hind. The mist is created by discharging water through special nozzles at very high pressure. Nitrogen cylinders used in conjunction with water cylinders, or pump systems are used to deliver water to the nozzles. The mist acts similar to gaseous extinguishing systems in that the mist can extinguish fires in shielded, obstructed locations which would not be reached by other directional water jets/droplets type systems. Some water mist systems have an additive injection component to introduce Class A or Class B foam concentrate into the piping. A small amount of foam concentrate added to the water supply can significantly improve the water mist system s performance when suppressing buried ordinary combustibles and liquid fuel spill fires. The resulting thin layer of foam solution blanketing the fuel spill reduces the amount of vaporization and inhibits the amount of radiant heat energy absorbed by the fuel. 84 RMS

LOGISTICS AND TRANSPORT OPERATIONS - ELEMENT 5 - UNIT IOG1 5.2 - Land transport Tankers UN CLASSIFICATION AND TRANSPORT OF HAZARDOUS MATERIALS In the UK and Europe, the Carriage of Dangerous Goods and Use of Transportable Pressure Equipment Regulations (CDGUTPER) 2009 and the European agreement ( Accord européen relatif au transport international des marchandises dangereuses par route ) (known as ADR), regulate the carriage of dangerous goods by road. The classes of dangerous goods according to ADR are: UN Class Dangerous Goods Classification 1 Explosives Explosive 2 Gases Flammable gas Non-flammable, non-toxic gas Toxic gas 3 Flammable liquid Flammable liquid 4 Flammable solids Flammable solid Spontaneously combustible substance 5 Oxidising substances Oxidising substance Substance which in contact with water emits flammable gas Organic peroxide 6 Toxic substances Toxic substance Infectious substance 7 Radioactive material Radioactive material 8 Corrosive substances Corrosive substance 9 Miscellaneous dangerous goods Miscellaneous dangerous goods Figure 5-16: Classes of dangerous goods. Source: ADR. Consignors must identify the hazardous substance that they are transporting. To assist in emergency the driver is responsible for ensuring that the correct paperwork for the load is to hand. For dangerous goods a Dangerous Goods Note should detail: Nature and quantity of dangerous goods. UN number or identification number. Proper shipping name. Class or division (subsidiary risk). Packing group (if required). All other required information. This has usually been accomplished through special marking and labelling to indicate the hazards of the consignment on the vehicle and inclusion of relevant information in the transport documents and also by the pleading and labelling displayed on the transport unit. Warning signs are used to alert emergency services and other road users that a vehicle is carrying dangerous goods which pose a greater risk to people, property and the environment than ordinary loads. Additional safety precautions will be needed to handle any incident involving the vehicle. Figure 5-17: Dangerous Goods Note. Source: NCEC. RMS 99