ALPHATECH TECHNOLOGIES s.r.o. Jeremenkova 88, Praha 4, Czech Republic SIRIUS II. User guide V 2.0

Similar documents
Smart GSM/GPS car alarms

PERMACONN PM1030 Includes DI300. Installation Manual

GSM PROTECT ANTI-THEFT ALARM WITH GPS TRACKING & MOBILE PHONE ALERTS

your silent and loyal servant

1. User features of the GSM dialer

Mobeye CM2410 GSM fire alarm communicator

1. Functions of GPS locator ETLOC-30S 3

HELPY QUICK-TL GSM INTL

To activate using remote control: press [ ] key once. To activate using keyboard: on panel keyboard [ ] keys once.

Installation manual: CA-1803BT Athos mode 1 for cars without an original remote control for central locking

GPS Vehicle Tracker (GPS+GSM+SMS/GPRS) User Manual (V1.0)


2G & 3G GSM Door Contact Alarm

GSM WIRELESS ALARM SYSTEM Model: GSM-0308W

Preface. Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock.

Profile. For a better understanding of this product, please read this user manual thoroughly before using it.

MOBILE CALL GSM Alarm System User s Manual

Wolf Guard Touch Keypad GSM Wireless alarm system User s Manual

INSTALLATION and OPERATING INSTRUCTIONS ARITERM GSM A2

SC-F3G User Manual 1.0

2G & 3G GSM Wireless Beam Alarm

EZY SWITCH. SMS-IRR-4 System Monitor Installation Manual

GSM 3G AUTO DIALLER. Remote monitoring & Control using your mobile phone. MODEL NUMBER 3GAD1

PART NO: TSMS. Designed in Australia by. Instruction Manual. Factory Car Alarm Upgrade Providing Alarm Notification Via SMS Messaging N517

DESCRIPTION OF KEYPAD (Access module with segments)

2G & 3G GSM Portable PIR Alarm

DYGIZONE GJD910 Lighting Controller & Enunciator

Kwêbeam GSM/Interface/Repeater Module

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

3G GSM AUTO DIALER. Remote monitoring & Control using your mobile phone. MODEL NUMBER 3GAD1

Intelligent Wireless GSM Alarm System

Version 1.03 January-2002 USER S MANUAL

BURGLAR ALARM PANEL BS-468

1. Introduction. 2. Product overview

GSM 3G AUTO DIALLER PLUS

3 User s settings. 3.3 Internal clock setting

PORTAL USER MANUAL. Mobeye WaterGuard-FS. Float sensor CM2300FS. SW version 5.n

V1.0. Smart Home Alarm System. User Manual. APP download via QR Code scanning. Please read the manual carefully before using.

Ontech GSM 9040/50. Reference Manual English -1 -

IP & SMS Alarm Communicator

Training 2 nd part. Agenda for second part

GSM RFID VOICE Alarm System

Any additional devices linked to the system ET08 (computer, sensors, relays etc.) must be approved by LST EN standard.

User Manual (LS-GSM-006)

Basic Installation Manual

JA-63 Profi User manual

MG Partition 64-Zone Wireless Console with GPRS/GSM Version 1.6. Section Programming Guide

JA-101K(-LAN)(-LAN3G) and JA-106K(-3G) Security System Control Panels

SolarSET GSM SolarSET GSM with a Beacon

The Windcrest Remote Alarm for Passenger and Goods Lifts with Optional BS EN81-28 & BS EN81-70

Other trade names mentioned in this document may be registered trademarks or trademarks of respective product manufacturers or vendor products.

User Manual & Setting Instructions

D3D Wi-Fi GSM Smart Alarm System -User Manual

GLOBAL. InstallatIon & operation manual

Security GSM Alarm System

IRIS Touch 200 Range Dialler Installation Manual. Version 1.4

Memcom Emergency Telephone

PageOne 2-way Pager Assured 2-way messaging for critical communications

Fitting instructions

System. For a better understanding of this product, please read this user manual thoroughly before using it.

USER S MANUAL HOME ENERGY SAVINGS REMOTE CAMERA INTERNET USER INTERFACE TEMPERATURE ALARMS BURGLARY PROTECTION DOOR SECURITY FIRE SAFETY

ECO601 OPERATING INSTRUCTIONS ME04

EC II GSM SE User Manual

It is necessary to match all peripherals with the EVOLVEO Alarmex main unit before the first use. For safety reasons, they are not factory paired.

All-In-One Wireless Security System V1.0. Model #: MG-6060

W I I T T U U R R A A C C O O R R P P O O R R A A T T I I O O N N S S D D N N B B H H D D

IRIS Touch 400 & 600 Range Installation Manual. Honeywell Galaxy Range. Version 2.0

CA60Plus. Installation manual

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide

MG5000 V2.4 MG5050 V2.4 SP5500 V2.4 SP6000 V2.4 SP7000 V2.4. Programming Guide

WM3000 WIRELESS MODULES

All-In-One Wireless Security System V1.0. Model #: MG Reference and Installation Manual

MPIP-620 GPS Vehicle Technical Specifications

SMART HOME SECURITY. Dual Network Communicating Alarm System with RFID INVINCIBLE. Instruction Manual. Customer Helpline

Inner Range FE3000S. Serial GSM Modem. P/No: INSTALLATION MANUAL

Wireless Keypad GKP-S8M

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE

reading carefully this guide, operating this system strictly on the standard procedure.

Memcom + Emergency Telephone

TYDOM 315. * _Rev.2* GSM domotics transmitter. 1. Presentation

BENTEL SECURITY reserves the right to modify the technical features of this product without prior notice.

S3 Sim Secual Alarm system with GSM transmitter

COMMUNICATOR ET08 / ET081

Labcom 200. Installation and User s Guide (230 VAC) Communication Unit

Sentient. Downloader Manual D4854

GSM Alarm System. User s Manual. Profile. MOBILE CALL GSM Alarm System

GSM CAR ALARM SYSTEM USER S MANUAL

GradeShift G2r/G3r INSTallaTIoN MaNUal

SMART SWITCH TECHNOLOGIES. SmartSwitch Yacht-Guard Model SMS-8 Vessel System Monitor Installation Manual

ProCom The App for Alarm Systems in the Protect Series Operating Manual

Conditions for the provision of services Valid from 1 November only for the Jablotron Alarms series of alarms

THA2 TEMPERATURE/ HUMIDITY/ DEWPOINT ALARM WITH LOGGING CAPABILITY. 99 Washington Street Melrose, MA Phone Toll Free

PRODUCT CATALOGUE. Cape Town 18 Darter Road Blue Water Estate Kommetjie. Gauteng 245 Louis Botha Avenue Orchards Johannesburg

HELPY CONTROLLER QUICK GUIDE

EP364 USER MANUAL ALARM AND MANAGEMENT SYSTEM

600 Range Dialer Installation Manual. Version 1.0

Quick Reference Guide

Remote switching machines with a SMS text from your mobile phone! Remote Monitoring your assets in the worldwide by your mobile Phone!

USER MANUAL Mobeye ThermoGuard CM2200

USER S MANUAL. Profile. MOBILE CALL GSM Alarm System

Transcription:

ALPHATECH TECHNOLOGIES s.r.o. Jeremenkova 88, Praha 4, Czech Republic www.alphatechtechnologies.cz SIRIUS II User guide V 2.0

Features: o Car position (GPS locating) with memory of last position (GPS signal failure) o During driving automatical position record every minute into memory includes date and time ( time is adjustable) In memory is saved last 4000 positions (cca 66 hours of driving ( 1 record per minute)) o Detection of position whenever you want by SMS o During Alarm is generating a call up to 8 phone numbers o During Alarm or power supply disconnection is sending SMS includes status and position o 3 Alarm inputs (alarm): activated by connection to +, activated by connection to ground, activated by current floating ( bypass ) o Output for remote blocking of engine by SMS o Remote blocking of device by SMS o Activation/deactivation by Dallas chip, RFID etc.. o Sound signalling o Remote setting of all parametres by SMS from authorised numbers only o Remote measurement of Back up Battery voltage Technical parametres: o Power supply range: 8-28V DC o Stand by consumption: cca 10 ma (Back up ACU charged) o Max current consumption: 1,5 A (peak call + charging Back up ACU) o Input ALARM-: alarm activation by short circuit to ground for time 0.1-9.9sec (default 0.3sec) o Input ALARM+: alarm activation by connection to + of power supply for time 0.1-9.9sec (default 0.3sec) o Input BYPASS: alarm activation by current floating > cca 100mA for time 0.1-9.9sec (default 3sec) o Output beeper output for connection of bell, beeper etc..: max. current cca 500mA o Blocking output output for relay connection to disconnect ignition: max. current cca 1000mA o GSM: EGSM 900 (class 4 2 W) GSM 1800 (class 1 1 W) Antenna connector FME o SIM card: 3/1,8 V o GPS: Leadtek (SIRFIII) Antenna connector SMA o Back up ACU: 4 V/2.6 Ah o Operation time without power supply : cca 24 to 100 hours up unit load o Protection against power supply polarity change o Automatical fuse and overvoltage protection o Operational temperature 20 až +50 C o Dimension: 80 x 50 x 35 mm o SMS position includes: latitude and longitude,date, GM time from detected position, movement speed 1

Red LED Alarm It lights up when some alarm input is activated. After fulfilment of inquiries (SMS, calls) lights off. Green LED GPS lighting GPS is ON, position valid flashing GPS is ON, position invalid not lighting GPS is OFF Green LED GSM Lighting of flashing GSM modul operation Green LED power supply lighting unit is ON, feeding is > 8V flashing unit is ON, feeding is < 8V not lighting unit is OFF GSM antenna GPS antenna Wire jumper of backup ACU DALLAS bypass alarm - alarm + Ground Black/ Red/ LED DALLAS 15 blocking beeper feeding 2

BASIC CONNECTION SCHEMATIC - MUST BE ALWAYS USED! might be supplemented by other combination of connection / Red/ Connection of Dallas (key) and grey Yellow/ Red/ 3

Connection of wireless card receiver ED 060 624 - Red- Black- ED 060 624 Yellow/ Red/ Alarm connection Yellow / Red / Alarm- 4 Alarm+

Alarm connection bypass Yellow/ Red/ Blocking connection Yellow/ Red/ 5

Connection of sound signalling for Key Yellow/ Red / Bell, beeper on12v (with own tone) Unit operation start 1. Connect cables from connector up selected connection schematics Do not connect the connector into the unit! 2. Insert SIM card. 3. Connect attached antenna GSM and GPS. 4. Double check correct polarity of power supply in connector as same as correct cables connection (not short circuit, etc ) 5. Connect the connector into the unit Green LED lights up with symbol battery. 6. Wait for registration of the unit into GSM network (LED GSM is flashing). 7. The unit is ready for operation. 6

LED Signalling symbol Light of LED functionality ƒƒƒ ƒƒƒ ƒƒƒƒƒƒƒƒƒƒ ƒƒƒ ƒƒƒ ƒ ƒƒƒ ƒƒƒ ƒƒƒƒƒƒƒƒƒƒ Connection of feeding from car - battery > 8V Connection of feeding from car - battery < 8V The unit is switched OFF (back up ACU is discharged) GSM operation (registration, SMS etc.) Stand by GPS is ON, position valid GPS is ON, position invalid GPS is OFF Activation of some services (power supply disconnection, ALARM etc.) LLED DALLAS ƒ ƒƒƒ ƒ ƒ Start of unit (cca 1 minute) LLED DALLAS LLED DALLAS LLED DALLAS LLED DALLAS LLED DALLAS ƒƒ ƒƒ ƒƒ Activated feeding from car - battery ƒƒƒƒƒ ƒƒƒ Activated feeding from Back up ƒ ƒƒƒƒ (5s light) code reception from key ƒƒƒƒƒƒƒƒƒƒ Ignition is ON (correct start) ƒ ƒ ƒ ƒ ƒ Ignition is OFF (correct start) Sound signalling - reading of attached key _ - record of key to SIM _ _ _ _ _ - incorrect start _ - ignition switch off _ _ 7

Telephone numbers saved on the SIM card Name Example of number function ADMIN +420123456789 Highest priority. It can SMS CAR,ON and CAR,OF deactivate and activate unit. It can sends also further SMS. To this number is sends SMS 'ALARM(AKU) + Cit' + position after activation signal Alarm or feeding ALARMS +420987654321 interruption (Aku), To this number is send SMS 'Incorrect start!' (start without key deactivation) To this number are also sends messages from operator (cit status) It can sends SMS except CAR ALARMx (x = 1..8) OPER CRED +420123000001 (ALARM1) +420123000032 (ALARM2) +420123000111 (ALARM3) +420012300012 (ALARM5) +420123004567 (ALARM6) 4603 (T-Mobile) *101# (T-Mobile) *104*# (Eurotel) It is dialling progresively after activation alarm signal until interruption of line (1,2,3,5), Progressive dialling is also ended by pick up at called part (in handset you hear interruption tone). From those numbers can be sends system SMS number, from which are received SMS of operator (cit status) Code to identify cit status Remote settings unit parametres: Number is in format 'tt*bb*pp*uu', when: ALTIM 05*10*02*35 KEY 1 'tt'.. 01-99 [decimal sec.] pulse duration time at input for alarm sensor (default 03 = 300 msec) 'bb'.. 01-99 [decimal sec.] current duration time for byppas alarm activation (default 30 = 3 sec) 'pp'.. 01-99 [min] time between position reading (default 01 min) 'uu'.. 35-39 [decimal volt] - min. voltage value of back up ACU (default 36 = 3,6 V) when voltage is lower the unit is automatically switch OFF '1'... registration of attached keys DALLAS (until ignition start by this is automatically rewritten to 0) '0'...unlocking by attach of registrated key DALLAS 8

Table of SMS commands identif. par. command body example description SMS reply Note ALARM 1 to 8, phone number ) 1 ALARM1,+42060212311 adding or change of phone number at positioni par. "OK" ALARM 1 to 8, ALARM2, erasing phone number on position par "OK" ADMIN phone number ) 1 ADMIN,+42060212311 adding or change of phone number ADMIN "OK" ADMIN erasing phone number ADMIN "OK" #1111#POLOHA #1111#POLOHA request for identification of position position PERMIT,DDMM,ddm, DDMM,ddmm PERMIT,3105,0206 permission for data access for 1 hour to memory of recorde "OK" d position. For transmission will be selected period betwee n dates DDMM and ddmm CAR, OF CAR,OF deactivation of unit ( unit react then for SMS "STAT" and " "OK" ADMIN only CAR,ON" only from ADMIN number CAR, ON CAR,ON unit activation "OK" ADMIN only BLOCK, ON BLOCK,ON closing of output for blocking (switch off ignition) "OK" for closing must be valid position reading and speed under 15 km/h BLOCK, OF BLOCK,OF unblocking "OK" RST RST unit restart "OK" STAT STAT identification of unit status programm version ABCDE Backup=x.xxV Battery=yy.yV Mode act Block on (Block of) cit A=blok (1 ON) B=key (1 od.) C=alarm (1 on) D=GPS (0 -off) E=ignition ALTIM, tt*bb*pp*uu 05*10*02*35 Remote setting of unit parametres "OK" CAL, ATD603123456; CAL,ATD603123456; unit generate a call to set number immediatelly after receivi ng ) 2 "OK" - call established "NO CARRIER" - unreachable "BUSY" - busy CAL, ATH CAL,ATH zaøízení ukonèí probíhající hovor CAL, AT+CPAS CAL,AT+CPAS identification of unit status "+CPAS: 0" - stand by "+CPAS: 3" - incoming call "+CPAS: 4" - current beying call CAL, AT+CSQ CAL,AT+CSQ identification of signal strength "+CSQ: 17,99" - first number befor e comma is signal strength(max 32 ), min. value for calling is cca 17 CAL, AT+CPBR=par. CAL,AT+CPBR=1 identification of phone number on the SIM at certain positio n par. +CPBR: 1,"+420602123111",14 5,"ALARM1" CAL, AT+CCLK=? CAL,AT+CCLK=? clock status in unit +CCLK: 00/01/01,01:17:36 ) 3 because clocks are set to 0 when u nit is switch off, running since 1.1. 00. It always shows operation time since last switch off ( short fails are not registrated) parametres in previous table 9

ALPHATECH TECHNOLOGIES s.r.o. Jeremenkova 88, Praha 4, Czech Republic www.alphatechtechnologies.cz ALPHATECH TECHNOLOGIES s.r.o. Jeremenkova 88 140 00 Praha 4 Czech Republic VAT: CZ27577350 Company is registe in the Commercial Register administe by the Municipal Court in Prague, Section C, Record 116886 Banking details: Komerční banka, account No. 43-7671450207/0100 IBAN: CZ0801000000437671450207 SWIFT: KOMBCZPPXXX