940ES Tankless Water Heater

Similar documents
940ES Tankless Water Heater

C1210ES Tankless Water Heater

C1050ES Tankless Water Heater

C1210ESC Tankless Water Heater

Bosch Greentherm T9800 SE 199 Gas Tankless Water Heater

940ESO Tankless Water Heater

Concentric Vent / Air Intake Kit Stainless Steel

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

Commercial Tankless Rack System

Commercial Tankless Rack System

MULTI-LINK UP TO 20 UNITS COMMON VENT UP TO 8 UNITS COMPLIES WITH LEAD FREE STANDARDS SAFETY FEATURES:

Commercial Tankless. Rack System TANKLESS WALL MOUNT LIGHTWEIGHT EXPANDABLE REDUNDANCY EASY FIELD INSTALLATION EASILY INTEGRATE STORAGE WARRANTY

GB Condensing Gas Boiler

SOLID. STATE. Commercial Tankless. Rack System TANKLESS WALL MOUNT LIGHTWEIGHT EXPANDABLE REDUNDANCY EASY FIELD INSTALLATION EASILY INTEGRATE STORAGE

Commercial Tankless Rack System

Tankless Condensing High Efficiency Water Heaters with Built-In Pump

Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse

Commercial Tankless Rack System

Tankless Condensing High Efficiency Water Heaters

COMMERCIAL-GRADE RESIDENTIAL GAS WATER HEATERS

Residential/Commercial Gas Condensing Tankless Models

Residential Gas Tankless Water Heater

SAFETY FEATURES: Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse

Bosch Buderus SSB255/399/512 Stainless Steel Condensing Boiler

iq251, Gen II Submittal Data

GB Condensing Gas Boiler

GB Condensing Gas Boiler

Bosch Buderus SSB1000TL/TL2/TL3/TL4 Stainless Steel Condensing Boiler

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Residential/Commercial Gas Tankless Water Heaters TANKLESS HIGH EFFICIENCY CONDENSING MODELS FEATURES INDOOR MODELS ATI-240H, ATI-340H, ATI-540H

Bosch Buderus SSB800/1000/1000TL Stainless Steel Condensing Boiler

iq1001, Gen II Submittal Data

The WCGH High Efficiency Commercial Water Heater with Storage Tank

10 : 1 Turndown Ratio

Bid Date: Date: Project Name: Project #: City/St/ZIP: Fuel Type: Natural Gas Propane. Engineer: Factory Option: Contractor: Key Features.

G515/7 Cast Iron Boiler

Crossover. Hybrid Water Heater HIGH EFFICIENCY. Advanced Heating & Hot Water Systems. w w w.htproducts.com

Suggested Specifications Prestige Excellence 110

G615/11 Cast Iron Boiler

Bosch Greentherm Series

NAVIEN AMERICA INC FITCH AVENUE IRVINE, CALIFORNIA, USA

On-Demand Water Heater Installation Manual and Owner s Guide

C 1050 ES - Natural Gas C 1050 ES - Liquefied Petroleum (LP) Gas

7 sizes: 55,000, 80,000, 110,000, 155,000, 199,000, 285,000 & 399,000 Btuh. One of a kind design from the inside, out!

DIVISION FINNED WATER-TUBE BOILERS

POWER VTX. Condensing Storage Water Heater. 500 to 1000 MBH 225 Gallon Tank 15-year Warranty. PVI.com ENGINEERED DUPLEX ALLOY

i200, Gen II i250, Gen II Submittal Data

Crossover. Hybrid Water Heater. High Efficiency. Advanced Heating & Hot Water Systems.

Conquest. Condensing Gas Water Heater. 199 to 300 MBH 100 Gallon Tank 15-year Warranty. PVI.com

Date: Bid Date: Model: i200 i200p. Project Name: Project #: Location: Fuel Type: Natural Gas Propane. Engineer: Contractor: Key Features.

MODEL GWH 2400 ES NG and GWH 2400 ES LP - INDOOR MODEL

DIVISION FINNED WATER-TUBE WATER HEATERS

C 1210 ES/ESC - Natural Gas C 1210 ES/ESC - Liquefied Petroleum (LP) Gas

Technology and design with Comfort and Energy Saving in mind. Instantaneous Gas Water Heater Series

Automatic Circulating Water Heaters

C 950 / 1050 ES C 950 / 1050 ES - Natural Gas / C 950 / 1050 ES - Liquefied Petroleum (LP) Gas

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS

MODEL GWH 2700 ES NG and GWH 2700 ES LP - INDOOR MODEL

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

Commercial Gas Water Heaters

MECHANICAL VENTING VERSATILITY

Installation Manual CONDENSING TANKLESS GAS WATER HEATER DANGER WARNING CAUTION CAUTION. Requests to Installers

TABLE OF CONTENTS BRADFORD WHITE BOILERS

G315/6 Cast Iron Boiler

TRONIC 6000C WH17 & WH27 Electric Tankless Water Heaters

Utica Boilers MAC Submittal

96.2% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS CON X US REMOTE CONNECT. MODBUS AND BACnet MSTP PROTOCOL

FINNED WATER-TUBE POOL HEATERS

DIVISION FINNED WATER-TUBE BOILERS

HIGH OUTPUT. Skin design RANGE

FINNED WATER-TUBE POOL HEATERS

advanced : technology

CAUTION. In order to use the water heater safely, read this installation manual carefully, and follow the installation

G315/5 Cast Iron Boiler

Installation and Operation Instructions Manual

Up to 94.6% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL CONDENSING BOILERS OPERATING CONTROL FEATURING A BUILT-IN CASCADING SEQUENCER

Residential & Commercial

WATER-TUBE POOL HEATERS

AFUE 95% Heating Input 50,000 to 200,000 Btuh

Installation Manual CONDENSING TANKLESS GAS WATER HEATER DANGER WARNING CAUTION CAUTION

XTHERM, TYPE WH - MODELS 1005A- 2005A DIVISION COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS

Commercial Gas Water Heaters

96% COMMERCIAL INDUSTRIAL HEATER. Condensing Gas Water Heating System. Thermal Efficiency

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

Tankless Water Heaters

RTG 199 HE INDOOR MODEL. RTG 199 HEN - Natural Gas RTG 199 HEX - Propane (LP Gas) Installation and Operation instructions

Gas-Fired Condensing Boilers A Green Start to Space & Water Heating

TL-Pro 175C/199C INDOOR MODEL. TL-Pro 175/199 C - Natural Gas TL-Pro 175/199 C- Propane (LP Gas) Installation and Operation instructions

WATER-TUBE POOL HEATERS

DI/RO GAS TANKLESS WATER HEATER

GN94DNSRSA GE Indoor Tankless Water Heater

Revitalize Building Mechanical Systems (4619)

Date: Project #: Engineer: Prepared By: Bid Date:

On-Demand Water Heater Installation Manual and Owner s Guide

Boilers Variable Fire Boilers

Greentherm 9800 SE 160/199 SEC 199

Installation, Operation and Owner s Manual. Power Vent System

ONQUEST. Featuring... Condensing Water Heater. Requires no tank linings or heat exchanger linings. Requires no anodes of any type. 10- year warranty.

Transcription:

Engineering Submittal Sheet Dimensions and Connections B C D C Combustion air inlet Exhaust outlet Optional combustion air inlet Top view Top view A Hot water outlet Cold water inlet E F Front view Side view H J C I Bottom view G Gas supply connection Bottom view Dimensions Unit A B C D E F G H I J Value Inches 30½ 17⅞ 5¼ 11¼ 2¾ 6⁵ ₁₆ 2⁵ ₁₆ 6½ 2¹ ₁₆ 4¹ ₁₆ Engineering Specifications Water heater shall be a Model Therm 940 ES. Plant shall consist of Model Therm 940 ES NG/LP tankless water heaters as manufactured by Bosch Thermotechnology Corp. Heater shall be CSA/ANSI Z21.10.3 listed. Heater shall have an input of 199 MBH with a gross output of 160.5 MBH when fired with natural gas. Unit shall operate with a minimum of 82% ANSI Z-21 efficiency. Tankless water heater shall have a recovery of 257 gallons per hour at a 77 F temperature rise. Tankless water heater shall have Low NOx emissions and is 2012 SCAQMD NOx certified to rule 1146.2. CONSTRUCTION Water heater shall be of gas fired, tankless design with a modulating power burner and negative pressure gas valve. Burner shall be capable of 10:1 turndown of firing, without loss of combustion efficiency. Primary heat exchanger/combustion chamber shall incorporate a multi pass copper tube and fin design with internal turbulators. Heat exchanger shall be rated for working pressure not less than 150 psig. Water heater 1 of 6 shall be equipped with a modulating water valve to improve temperature stability. Exhaust outlet connector shall be of corrosion resistant metal, with a 3 diameter flue connection. The water heater control system shall be a single printed circuit board in water-resistant plastic enclosure. The entire system shall be Underwriters Laboratories approved. The control system shall contain: embedded control board incorporating LCD display to read temperature, and tactile buttons for output power, temperature, and programming control; CPU board which houses all control functions; power transformer; ignition spark module; and unique connections for each sensor or component. The control board shall be field replaceable. The combustion safeguard/flame monitoring system shall utilize spark ignition and a rectification type flame sensor. The control panel hardware shall support wireless remote communications if the wireless module is installed. The controls shall include extensive self-diagnostic capabilities

Engineering Specifications that incorporate a minimum of 18 separate fault codes and 8 programmable system categories. The water heater comes equipped with power cord and shall operate on 120V/1/60Hz electrical service. INSTALLATION All aspects of installation of Water Heater Plant shall be in strict accordance with manufacturer s instructions. Materials shall conform to all manufacturer s recommendations including a manufacturer listed vent system. Water heater plant piping shall be field constructed of materials as specified. Water heater shall be installed with individually isolating shutoff valves for service and maintenance, and a hot water hose connection for field testing. Unit shall have an ASME approved temperature/pressure relief valve with a setting of 150 psig. Water heater shall require a minimum gas pressure of 3.5 W.C. (Natural Gas) at 1,000 scfh (full load rated capacity). MODE OF OPERATION Heater shall include integral factory wired operating controls to control all operation and energy input. Control of discharge water temperature shall be set through an internal setpoint with a field adjustment of 100 F to 140 F. A high temperature accessory shall be available that when installed allows for field selectable discharge set point temperatures between 100 F and 184 F. Heater shall be capable of maintaining the outlet temperature within an accuracy of ±3 F. This shall be accomplished by modulation of firing rate from 100% to 10% of rated input. Unit shall operate with an Inverse Efficiency Curve, with maximum efficiency achieved at minimum firing input. CONTROLS INTEROPERABILITY The control board may be linked to other Bosch tankless water heaters through the use of a cascading kit. This accessory shall cause the unit to perform as described above while activating or deactivating other units in the system. Additional Bosch tankless water heaters shall be plumbed in parallel and located near the main unit. WARRANTY The heat exchangers shall carry a 15-year warranty against leakage due to defects in materials or workmanship or corrosion in a residential, non-direct recirculation system, subject to the manufacturer s water quality requirements. All other parts and components shall carry a 5 year warranty against defects in materials or workmanship. OR The heat exchangers shall carry a 5-year warranty against leakage due to defects in materials or workmanship or corrosion in a commercial installation, subject to the manufacturer s water quality requirements. All other parts and components shall carry a 5 year warranty against defects in materials or workmanship. Performance Data Unit Value Maximum gas input BTU 199,000 Minimum input BTU 19,900 Maximum output BTU 160,500 Minimum output BTU 18,300 Thermal efficiency % 83 2 of 6

Operational Data Unit Value 940 ES NG / Natural Gas - part number 7703311075 940 ES LP / Liquid Propane - part number 7703411073 Weight lbs 67 Electrical voltage mains VAC / Hz 120 / 60 Power consumption max load A 2.5 Power consumption idle ma 40 Min. Inlet gas pressure NG / LP Inch W.C. 3.5 / 8 Max. Inlet gas pressure NG / LP Inch W.C. 10.5 / 13 Maximum Output Temperature F 140 Max. Working pressure psi 150 Min. Working pressure psi 30 Min. Activation rate GPM 0.5 Relief valve pressure rating psi 150 Venting category III Approved vent pipe material Approved combustion air pipe material Sealed single wall stainless steel (AL29-4C) Sealed PVC or any other rigid pipe Clearances W1 W5 W3 W1 W1 W2 W4 Top View Front View Description Unit Minimum clearance Side clearance W1 Inch 1 Front clearance W2* Inch 1 Top clearance W3 Inch 12 Floor clearance W4 Inch 12 * 24 inches recommended for servicing. 3 of 6 Rear clearance W5 Inch 0

Required direct vent terminal clearances (twin pipe / concentric penetration) Clearance Data Item Description Value Canadian installations ¹ ) U.S. installations ² ) A Clearance above grade, veranda, porch, deck or balcony Inch 12 12 B Clearance to window or door that may be opened Inch 36 12 C Clearance to permanently closed window Inch * * D Vertical clearance to ventilated soffit located above the vent terminator within a horizontal distance of 2 feet (61cm) from the center line of the terminator Inch * * E Clearance to unventilated soffit Inch * * F Clearance to outside corner Inch * * G Clearance to inside corner Inch * * H Clearance to each side of center line extended above meter/ regulator assembly 36 in. within a height 15 feet above meter/ regulator assembly I Clearance to service regulator vent outlet Inch 36 * J Clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other application Inch 36 * * K Clearance to mechanical air supply inlet Inch 72 36 in. above if within 10 feet horizontally L Clearance above paved sidewalk or paved driveway located on public property Inch 84 ³ ) * M Clearance under veranda, porch deck or balcony Inch 12 ⁴ ) * 1) In accordance with the current CSA B149.1 Natural Gas and Propane Installation Code 2) In accordance with the current ANSI Z223.1 / NFPA 54 National Fuel Gas Code 3) A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and serves both dwellings. 4) Permitted only if veranda, porch, deck or balcony is fully open on a minimum of two sides beneath the floor. * For clearances not specified in ANSI Z223.1 / NFPA 54 or CSA-B149.1, one of the following shall be indicated: a) A minimum clearance value determined by testing in accordance with section 2.20, or; b) A reference to the following footnote: Clearance in accordance with local installation codes and the requirements of the gas supplier. 4 of 6

Required other than direct vent terminal clearances (single pipe penetration) 6720608836-23.1Av Clearance Data Item Description Value Canadian installations ¹ ) U.S. installations ² ) A Clearance above grade, veranda, porch, deck or balcony Inch 12 12 B Clearance to window or door that may be opened Inch 36 4 feet below or to side of opening; 1 foot above opening C Clearance to permanently closed window Inch * * D Vertical clearance to ventilated soffit located above the vent terminator within a horizontal distance of 2 feet (61cm) from the center line of the terminator Inch * * E Clearance to unventilated soffit Inch * * F Clearance to outside corner Inch * * G Clearance to inside corner Inch * * H Clearance to each side of center line extended above meter/ regulator assembly 36 in. within a height 15 feet above meter/ regulator assembly I Clearance to service regulator vent outlet Inch 36 * J Clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other application Inch 36 * 4 feet below or to side of opening; 1 foot above opening K Clearance to mechanical air supply inlet Inch 72 36 in. above if within 10 feet horizontally L Clearance above paved sidewalk or paved driveway located on public property Inch 84 ³ ) 84 M Clearance under veranda, porch deck or balcony Inch 12 ⁴ ) * 1) In accordance with the current CSA B149.1 Natural Gas and Propane Installation Code 2) In accordance with the current ANSI Z223.1 / NFPA 54 National Fuel Gas Code 3) A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and serves both dwellings. 4) Permitted only if veranda, porch, deck or balcony is fully open on a minimum of two sides beneath the floor. * For clearances not specified in ANSI Z223.1 / NFPA 54 or CSA-B149.1, one of the following shall be indicated: a) A minimum clearance value determined by testing in accordance with section 2.20, or; b) A reference to the following footnote: Clearance in accordance with local installation codes and the requirements of the gas supplier. 5 of 6

Water Heating Capacity Curve Flow Rate (GPM) 13 12 11 10 9 8 7 6 5 4 3 2 1 0 10 20 30 40 50 60 70 80 90 Temperature rise ( F) 100 110 120 130 140 Water Heating Capacity Data Temperature Rise F Flow Rate GPM 35 9.4 45 7.3 55 6.0 65 5.1 75 4.4 90 3.7 100 3.3 120 2.8 140 2.4 Tankless Components Components Legend 1 Flue gas collector 2 3 Heat exchanger Flame sensor 4 Primary fan (Mixer) 5 Hot water temperature sensor 6 LCD display 7 On/Off button 8 Reset button 9 Program button 10 Flue gas limiter 11 Heat exchanger overheat sensor (ECO) 12 Ignition electrodes 13 Observation window 14 Backflow temperature sensor 15 Secondary air fan 16 17 Gas valve Water valve and cold water temperature sensor 18 Control unit 19 Up button 20 Down button 21 LED 6 of 6