D Series Air Cooled Condensing Units 3 to 22 HP Brochure MAY, 2007

Similar documents
MEA. Air Cooled Condensing Units 3 to 22 HP Brochure September, Visit us on the web:

MiniLine Air Cooled Condensing Units -1/2 to 6 HP

Kramersaver Air Cooled Condensing Units

Table A-4...Professional and Do-It-Yourself Improvement Expenditures by Homeowner Characteristics: 2007

Table W-4...Total Improvement Expenditures by Homeowner Characteristics:

Table A-4...Professional and Do-It-Yourself Improvement Expenditures by Homeowner Characteristics: 2013

Tempra / DHC-E. The Finest Tankless Electric Water Heaters Available! Simply the Best Featuring Advanced Microprocessor Control

Oklahoma and Texas Interdependency Along the I-35 Corridor

Griddle Stands REFRIGERATORS & FREEZERS. Call us toll free at (800) INNOVATIVE DESIGNS FOR YOUR FOODSERVICE NEEDS

Next-Gen Uni-Pak 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

T H I R D Q UA R T E R

Inventory Management Guide

BULK PURCHASE DISCOUNTS Valid for purchases any time of year

Simply the Best WHOLE HOUSE COMFORT SAVE WHOLE HOUSE TANKLESS ELECTRIC WATER HEATERS

F O U R T H Q UA R T E R

Limestone Cements. Why are we doing this? What are they? What s in it for you? Limestone Cements, Holcim (US) Inc.

Space Heating with Solar Energy

ADDRESS (NO PO BOX) COMMUNICATIONS GENERAL INFORMATION. First Name*: John. Last Name*: Smith. Job Title*: President Company Name*: Custom Homes

Advanced Microprocessor Control The Finest Tankless Electric Water Heaters Available! DHC-E / Tempra

Simply the Best WHOLE HOUSE COMFORT SAVE WHOLE HOUSE TANKLESS ELECTRIC WATER HEATERS

horizontal air discharge outdoor discus condensing unit

Tempra Series WHOLE HOUSE TANKLESS ELECTRIC WATER HEATERS Whole House Comfort

Thermobank Hot Gas Defrost 12 through 70 HP

ADVANTAGE SERIES. Popular Technologies for Outdoor Living

J A N UA RY J U N E

Featured Fish-Week ofmay 29th

Air-Cooled Condensing Units with Bitzer Compressors

Bosch Tankless Water Heater Troubleshooting Guide

Model VDC Direct-Drive Remote Air-Cooled Condensers

Major U.S. Cities Using National Standard Fire Hydrants, One Century After the Great Baltimore Fire

LK-TSSTB July 2009 FPO HP Two Stage Condensing Units and Systems Technical Guide. with Bitzer Compressors.

Standards and Safety Update

Bar Equipment BOTTLE, KEG & BACK BAR COOLERS INNOVATIVE DESIGNS FOR YOUR FOODSERVICE NEEDS

This presentation is posted for public use. ACEEE does not endorse any product or service.

HOUZZ & HOME. Overview of U.S. Renovation in 2017 and Houzz Inc.

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

- Residential Fire Sprinkler -

Table W-4...Total Improvement Expenditures by Homeowner Characteristics:

2018 PRICING. alderonind.com STANDARD PRODUCTS

URBAN FLOODING A GROWING NATIONAL CHALLENGE. Samuel D. Brody, Josh Gunn, Jayton Rainey, Wesley Highfield Texas A&M University

All Product Specifications

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

MAXA-MI$ER Energy recovery solutions

Department of City & Metropolitan Planning, University of Utah.

All Product Specifications

Head Pressure Control Application Guide

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

T8131C Programmable Thermostat OWNER S GUIDE

Presentation to NC Home Inspectors Licensure Board April 7, Opportunities and Partnerships

MAC N-407 Air-Cooled Chiller

Commercial High-Efficiency Condensing Units

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

MACH N-407 Heat Pump Air-Cooled Chiller

Overview of Biosolids Composting Science, Production and Use Albert Cox Kuldip Kumar

CONDENSING UNITS-AIR SUBMITTED BY : Poppy Hudson PROJECT : Brooks Landing REV DATE : 07 Dec 2017 ORDER # : A00

Fire Sprinkler Success Stories: How do Sprinklers Save Lives. Viking Group, Inc.

USE OF A LOWER RATE WHEN APPLIED ON CEREALS AT THE HERBICIDE TIMING (FEEKES 4-6) - AL, AR, AZ ETC.

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

ERVB ENERGY RECOVERY VENTILATORS. Form No. PDS ERV.64.1

Condensing Units CUS 15-60

Hello. What can I do for you? QUALITY CUSTOMER SERVICE. Joseph Griffith Regional Sales Manager. Cooling Tower Depot is Global, I am Local

Standard Procedure s for Tenant Fire Sprinkler Work

Inventory Management Guide

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

Air-Cooled Condensing Units with Compact Screw Compressors

Medina. Laminate Casegoods

Commercial High-Efficiency Condensing Units

Fresh Air Ventilation

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

INFINITI K APPLICATIONS MANUAL. Indoor Residential and Tankless Water Heaters. Warning: Follow each appliance's instructions precisely.

Specifications and Performance S2H

STELLA Cert no. BV-COC

Low Profile Unit Cooler. ECM Motors. All-Temp²B. Small to Medium Walk - Ins. Coolers & Freezer Applications. Now available with optional

Product Data ERVC. Energy Recovery Ventilators. Features

PACKAGE AIR CONDITIONER

Catalog Air Cooled Split System Condensing Units for Rooftop Systems and Air Handlers

Air-Cooled Condensing Units with Screw Compressors. Technical Bulletin Low Temperature Models SSV DSV

Air-Cooled Split System Condensing Unit for Rooftop Systems and Air Handlers

R4H4. Product Specifications

R4H4. Product Specifications

LOW PROFILE UNIT COOLER

LUMINARY EXECUTIVE EXECUTIVE SUITES ALSO OFFERED WITH A SELECTION OF PENINSULA DESKS TO PROMOTE COLLABORATION WITH TEAM MEMBERS.

NOW I 50% OFF. CALL TODAY! H.L. Flake McDonald Dash ORDER ONLINE! HLFLAKE.COM BUY AT LIST PRICE

Continuing Education Units (CEU)

Unit Dimension. Unit Nomenclature DEHUMIDIFIER NOMENCLATURE UNIT VOLTAGE: 2: 240/1/60 5: /3/60 9: 480/3/60 8: 600/3/60

Programmable Load Controller USER S GUIDE

Installation, Start-Up and Service Instructions

N4H4. Product Specifications

MODELS VA3B, VB5B VC5B

DOWNLOAD OR READ : KITCHEN AND BATH SOLUTIONS CLARKSVILLE TN PDF EBOOK EPUB MOBI

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

AIR F LOTATION A F D ISSOLVED INNOVATIVE PUMP TECHNOLOGY FOR. DAF Pumps

WCH5**4. Product Specifications

CATALOG. SKYPAK Self-Contained Heating/Cooling Units

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

3-22 HP CONDENSING UNITS Technical Guide

WLCG/WLHG. Specifications and Performance WLCG/WLHG. (with EMI AmericaSeries condensers)

TrilliumSeries. Condenser

CT1500, CT1501, CT1502, CT1503

Transcription:

D Series Air Cooled Condensing Units 3 to HP Brochure 530.0 MAY, 007 MEA 3050 Enterprise St., P.O. Box 030, Brea, CA 98-030 Tel (74) 59-935 FAX (74) 59-703 www.russellcoil.com

The outdoor housing of our condensing units have completely re-engineered. Access to all components is now more convenient than ever. Quick removal of top and side panels allows quick access to everything. The hinged control panel door swings wide open for maximum clearance while the unit is being serviced. STAINLESS STEEL BRAIDED HOSES* OSHA APPROVED FAN GUARDS SUCTION AND DISCHARGE VIBRATION ELIMINATORS HIGH-EFFICIENCY PSC FAN MOTORS LIQUID LINE SIGHT GLASS* HINGED CONTROL PANEL DOOR SOLID STATE OIL CONTROL* SUCTION ACCUMULATOR* INTERLOCKING* NON-FUSED DISCONNECT SWITCH The large control panel has abundant space for the controls you choose. They are intelligently arranged and laid out in a logical fashion which is easy to understand and work with. Each control and wire is clearly marked with a name or number as shown on the wiring diagram which is conveniently affixed to the control panel door. CONTROL VOLTAGE TRANSFORMER CONTROL CIRCUIT FUSES DEFROST CLOCK* HINGED DOOR RUSSAVER PRESSURE CONTROL* COMPRESSOR CONTACTOR POWER TERMINAL BLOCK EVAP FAN MOTOR CONTACTOR* BLOCK OUT RELAY* EVAPORATOR DEFROST CONTACTORS* EVAPORATOR SEQUENCING RELAYS* NON-FUSED DISCONNECT SWITCH* DOOR INTERLOCK* EVAPORATOR FAN AND HEATER SUB-CIRCUIT FUSING* CONDENSER FAN MOTOR CAPACITORS

MODEL NUMBER NOMENCLATURE D L D L 44 D STYLE UNIT STYLE OF UNIT E = Indoor Unit L = Outdoor unit w/flooded controls S = Outdoor unit w/russ-saver controls C = Outdoor unit w/no head pressure controls COMPRESSOR STYLE D = Copeland Discus C = Carlyle* B = Bitzer* S = Special* REFRIGERANT TYPE = R- 44 = R-404A / R-507 34 = R-R-34a OPERATING RANGE H = High Temp (+0 F to +45 F Suction Temp) M = High/Medium Temp (-0 F to +45 F Suction Temp) L = Low Temp (-40 F to 0 F Suction Temp) NOMINAL HORSEPOWER ELECTRICAL COMPONENTS CONDENSER PIPING COMPONENTS RECEIVER HOUSING Fusible plug All weather housing Control panel - with hinged door Raised galvanized steel base FEATURES AT A GLANCE Crankcase heater Oil failure control - as required High-Low pressure control - manual(high)/automatic(low)rest Compressor contactor Control circuit fuses - standard 30/ Power terminal block Copper tubes with Aluminum fins Subcooling circuit Fan motor - PSC overload protection Fan blade - individually balanced Fan guard - split for easy motor access: UL listed Suction line filter Suction line vibration eliminator Liquid line filter/drier Sight glass/moisture indicator Discharge line vibration eliminator Inlet and outlet isolation valves Russ-Saver - all ambient energy saver LOW AMBIENT Pressure fan cycling control - not available on 3HP - 6HP low temps. CONTROLS Flooded condenser UL/cUL listed all models TESTING Leak detection, Dielectric & Run test Dry nitrogen holding charge OPTIONS: 4 year extended compressor warranty Air defrost time clock Compressor unloading Copper or coated condenser fins Crankcase pressure regulator Electric Defrost with heater contactors, timer, block out relay Evap sub circuit fusing Fused disconnect Heated and insulated receiver * Contact factory for details. 3 MODEL DE DC DS DL N/A N/A N/A Hot Gas Defrost components Liquid line solenoid valve Oil separator Oversized reciever Phase loss monitor Sentronic oil saftey control Spring loaded relief valve Staninless steel hoses Suction line accumulator Non-Fused Disconnect N/A N/A

RUSS-SAVER The initial cost of quality refrigeration equipment is a substantial investment. But the costs of installation and operation are also formidable. Rising to the challenge, Russell engineers have designed the RUSS-SAVER system to meet the highest standards of performance and reliability while effectively addressing the problem of these profit draining costs. REDUCED INSTALLATION COSTS The installation of a refrigeration system using RUSS-SAVER requires a smaller refrigerant charge than equipment which utlilze other types of low ambient controls. As the more expensive zero ozone depleting, refrigerants become the refrigerants of choice, the reduced charge requirements provided by RUSS-SAVER affords substantial and immediate cost saving benefits. REDUCED OPERATING COSTS The most expensive part of an operating refrigeration system is the cost of energy to operate the compressor. Day and night, year after year, the cost of electricity to operate your eqiupment is unrelenting. These dollars are pulled right from your bottom line. A typical installation provides for equipment which is designed to furnish adequate cooling on the hottest of days. The RUSS-SAVER system is designed to meet this need but also be flexible enough to take advantage of reduced ambient conditions during off-peak times. As the outside air temperature decreases, head pressures are allowed to drop. This action results in increased efficiency, requiring less energy and saving substantial amounts of your money! RUSS-SAVER even saves money during hot weather. The sub cooling loop provided in the condenser of the RUSS-SAVER condensing unit increases the system efficiency /% for each degree of sub cooling provided, thereby making the compressor s job easier. RUSS-SAVER S efficiency saves you money during summer operation and even more during the winter months. 4

RUSS-SAVER ENERGY SAVINGS CALCULATIONS To estimate your average monthly savings: ) Select a RUSS-SAVER system that meets your refrigeration requirements. ) Determine the Average Annual Outdoor Air Temperature from the table below. 3) Using the Projected Monthly Savings graph, locate the system nominal horsepower at the bottom of the graph (the nominal system horsepower can be derived from the model number nomenclature). 4) Go straight up to the appropriate Average Annual Outdoor Air Temperature curve, and then go horizontally to the left to determine your Estimated Monthly Average Savings. 5) To calculate your Estimated Monthly Saving for an energy cost other than $0.0 KWH, divide the Estimated Monthly Savings by 0.0 and multiply by your local electric utility rate. 6) To determine your Estimated Yearly Savings, multiple the Estimated Monthly Savings number by. AVERAGE ANNUAL OUTDOOR AIR TEMPERATURE STATE & ANNUAL STATE & ANNUAL STATE & ANNUAL STATE & ANNUAL STATION AVG. F STATION AVG. F STATION AVG. F STATION AVG. F AL Mobile 70 IA Des Moines 50 NM Albuquerque 60 VT Burlington 45 AK Juneau 40 KS Wichita 55 NY Buffalo 45 VA Richmond 60 AZ Phoenix 70 KY Louisville 55 New York 55 WA Seattle 50 AR Little Rock 60 LA New Orleans 70 NC Charlotte 60 WV Charleston 55 CA Los Angeles 60 ME Portland 45 ND Bismarck 45 WI Milwaukee 45 San Francisco 55 MD Baltimore 55 OH Cleveland 50 WY Cheyenne 45 CO Denver 50 MA Boston 50 Columbus 50 CT Hartford 50 MI Detroit 50 OK Oklahoma City 60 CANADA DE Wilmington 55 MN Sault St. Marie 40 OR Portland 55 ALB Calgary 40 D.C. Washington 55 Minneapolis 45 PA Philadelphia 50 B.C. Vancouver 50 FL Jacksonville 70 MS Jackson 65 RI Providence 50 MAN Winnipeg 35 Miami 75 MO St. Louis 55 SC Columbia 65 N.B. St. John 45 GA Atlanta 60 MT Great Falls 45 SD Sioux Falls 45 N.F. St. John's 40 HI Honolulu 75 NE Omaha 50 TN Nashville 60 N.S. Halifax 45 ID Boise 50 NV Reno 50 TX Dallas 65 ONT Toronto 45 IL Chicago 50 NH Concord 45 El Paso 65 QUE Montreal 45 IN Indianapolis 50 NJ Atlantic City 55 UT Salt Lake City 50 YUK Dawson 5 RUSS-SAVER PROJECTED MONTHLY SAVINGS @ $0.0/KWH 00 ESTIMATED AVERAGE MONTHLY SAVINGS ($) 80 60 40 0 00 80 60 45 o F 55 o F 65 o F 75 o F AVERAGE ANNUAL OUTDOOR TEMPERATURE 40 0 Baseline represents typical flooded system 0 5 6 7 8 0 5 0 SYSTEM HORSEPOWER 5

BTUH CAPACITIES R- HIGH TEMP SUCTION TEMPERATURE F 90 AMBIENT DE/DC/DS/DL +45 +40 +35 +5 +0 +0 5H 7H 8H 0H H 5H 79,700 09,300 36,000 58,600 83,000 0,300 7,600 99,700 4,00 44,900 66,00 9,600 65,900 90,600 3,000 3,00 50,00 75,800 53,600 74,00 9,800 09,00 6,00 45,00 47,900 66,800 83,700 98,800 3,00 3,300 37,800 53,600 67,00 80,00 90,400 05,800 95 AMBIENT DE/DC/DS/DL +45 +40 +35 +5 +0 +0 5H 7H 8H 0H H 5H 76,900 05,800 3,600 53,400 76,800 03,300 70,00 96,500 0,00 40,00 60,500 86,300 63,600 87,800 09,400 7,900 45,00 73,00 5,700 7,900 89,800 05,600,800 40,700 46,300 64,800 80,900 95,500 09,00 7,00 36,400 5,00 64,900 77,500 87,300 0,600 00 AMBIENT DE/DC/DS/DL +45 +40 +35 +5 +0 +0 5H 7H 8H 0H H 5H 74,00 0,00 7,00,00 70,700 96,600 67,500 93,300 6,00 35,500 54,900 80,00 6,300 84,900 05,700 3,600 40,00 64,700 49,900 69,600 86,800 0,000 7,600 36,300 44,700 6,800 78,00 9,300 05,400 3,300 35,00 50,500 6,600 74,800 84,300 99,400 0 AMBIENT DE/DC/DS/DL +45 +40 +35 +5 +0 +0 5H 7H 8H 0H H 5H,500 94,700 8,300 37,600 53,300 83,600 6,500 86,500 08,00 5,900 39,00,300 56,800 78,800 98,500 5,000 5,900 54,00 46,300 64,900 80,800 94,900 05,700 7,900 4,500 58,600 7,800 85,800 94,700 5,700 3,500 47,400 58,00 69,300 75,800 93,300 6

BTUH CAPACITIES R- LOW TEMP 90 AMBIENT 95 AMBIENT 00 AMBIENT 0 AMBIENT SUCTION TEMPERATURE F DE/DC/DS/DL 0-0 -0-5 -30-40 3L 4L 5L 6L 8L 9L 0L 5L L 3,000 36,500 4,600 50,500 59,300 67,900 77,300 0,400 9,500 3,500 8,000 33,00,700 46,600 53,400 60,400 86,800 00,600 7,600 0,700 4,600 9,600 35,600 40,700 45,500 66,400 77,800 5,00 7,400 0,900 5,500 30,700 35,00 39,600 57,400 67,900,800 4,600 7,600,00 6,600 30,00 33,900,800 58,700 8,700 9,900,000 4,800 9,00,300 3,300 33,900 40,600 DE/DC/DS/DL 0-0 -0-5 -30-40 3L 4L 5L 6L 8L 9L 0L 5L L 9,400 34,800 40,300 47,900 56,400 64,700 73,400 05,400 3,00,300 6,700 3,300 36,700 44,300 50,900 57,400 8,900 95,700 6,700 9,700 3,300 8,00 33,900,800 43,00 63,400 74,000 4,300 6,600 9,800 4,00 9,00 33,500 37,600 54,800 64,600,00 3,900 6,600 0,00 5,300 8,700 3,00 46,600 55,800 8,00 9,400,300 4,000 8,00 0,300,00 3,300,600 DE/DC/DS/DL 0-0 -0-5 -30-40 3L 4L 5L 6L 8L 9L 0L 5L L 7,900 33,00,00 45,500 53,600 6,500 70,500 00,500 8,00,00 5,500 9,600 34,800 4,00,400 55,00 79,00 9,800 5,900 8,800,00 6,700 3,300 36,900 4,500 60,500 7,000 3,600 5,900 8,800 3,000 7,800 3,800 36,00 5,300 6,000,500 3,300 5,700 9,00 4,00 7,300 3,000 44,500 53,600 7,800 9,000 0,700 3,300 7,00 9,300,300 30,800 37,00 DE/DC/DS/DL 0-0 -0-5 -30-40 3L 4L 5L 6L 8L 9L 0L 5L L 4,300 8,600 3,500,400 45,700 53,00 6,700 86,500 0,300 8,400,900 4,500 9,400 35,900 4,800,300,000 79,500 3,800 6,00 8,00,500 7,500 3,900 36,300 5,000 6,500,800 3,700 5,500 9,400 3,700 7,500 3,600 45,000 53,700 0,000,400 3,000 6,00 0,500 3,600 7,00,300 46,400 6,800 7,800 8,900,00 4,700 6,700 8,600 6,500 3,00 7

BTUH CAPACITIES R-404A / R-507 - HIGH / MEDIUM TEMP SUCTION TEMPERATURE F 90 AMBIENT DE/DC/DS/DL +45 +35 +5 +0 +0 0-0 5M44 6M44 7M44 8M44 0M44 M44 5M44 8,000 03,00 4,800 35,000 59,600 97,000 0,000,800 86,300 96,700 4,600 35,300 6,300 79,300 57,00 7,00 80,500 96,000 3,700 35,500 5,00 5,700 64,300 73,00 87,400 03,700 3,500,00 4,800 5,700 59,800 7,500 85,00 0,700 4,000 33,00 4,000,00 57,500 69,000 8,400 9,700 6,000 3,300,00 45,600 54,500 65,700 73,800 95 AMBIENT DE/DC/DS/DL +45 +35 +5 +0 +0 0-0 5M44 6M44 7M44 8M44 0M44 M44 5M44 76,700 97,600 09,000 8,300 5,700 87,000 99,00 65,00 8,700 9,800 08,900 8,600 53,00 70,00 54,00 67,300 76,400 9,00 08,000 8,600 43,400,900 60,800 69,400 83,000 98,500 7,00 3,000 39,500,900 56,700 67,900 80,900 96,500 08,00 3,300,800 45,600 54,600 65,500 78,00 87,900 4,600 30,500 36,00 43,300 5,800 6,300 70,000 00 AMBIENT DE/DC/DS/DL +45 +35 +5 +0 +0 0-0 5M44 6M44 7M44 8M44 0M44 M44 5M44 7,00 9,900 03,00,400 43,400 76,400 87,900 6,300 76,900 86,800 03,00,600 44,400 60,500 5,000 63,400 7,00 86,300 0,00,300 35,300 46,00 57,300 65,600 78,600 93,00 0,600 3,600 37,00 46,00 53,600 64,300 76,500 9,000 0,000 9,500 36,600 43,00 5,700 6,900 73,800 8,900 3,00 8,800 34,00 4,000 49,000 58,800 66,00 0 AMBIENT DE/DC/DS/DL +45 +35 +5 +0 +0 0-0 5M44 6M44 7M44 8M44 0M44 M44 5M44 6,400 78,00 88,900 05,400 3,800 5,900 6,00 5,00 65,400 74,900 89,500 05,000 4,400 37,700 43,300 53,900 6,300 74,900 88,00 04,500 6,00 39,00,700 56,600,00 80,400 95,00 06,000 3,600 39,00 46,300 55,800 66,00 78,400 87,500 5,00 3,00 37,00 44,900 53,500 63,500 7,00 9,700 4,400 9,500 35,600 4,300 50,600 56,700 8

BTUH CAPACITIES R-404A / R-507 - LOW TEMP SUCTION TEMPERATURE F 90 AMBIENT DE/DC/DS/DL 0-0 - 5-0 - 5-30 - 40 3L44 4L44 5L44 6L44 8L44 9L44 0L44 L44 5L44 L44 3,00 39,300 46,500 53,00 67,000 77,700 85,600 9,000 4,00 35,500 6,600 3,400 37,400 4,00 53,500 6,00 69,500 74,00 9,400 0,700 3,600 7,700 33,400 37,300 47,300 55,300 6,000 66,00 8,000 99,500 0,600 4,400 9,500 3,800 4,700 49,000 55,000 58,800 7,500 88,000 7,900,300 5,900 8,600 36,700 43,00,300 5,800 6,700 79,00 5,500 8,400,500 4,700 3,900 37,900 4,00 45,00 54,700 70,00,00 3,00 6,400 8,00 3,700 8,500 3,000 3,00 40,800 54,300 95 AMBIENT DE/DC/DS/DL 0-0 - 5-0 - 5-30 - 40 3L44 4L44 5L44 6L44 8L44 9L44 0L44 L44 5L44 L44 30,600 37,300 44,000 50,500 63,600 73,700 8,00 87,400 08,600 8,600 5,300 9,800 35,400 40,000 50,800 59,000 65,900 70,400 9,900 05,00,400 6,300 3,600 35,400 44,900 5,500 57,800 6,800 8,00 94,400 9,600 3,00 7,900 3,00 39,600 46,500 5,00 55,800 73,600 83,500 7,000 0,00 4,500 7,00 34,800 40,900 45,800 49,00 63,900 75,00 4,700 7,400,300 3,400 30,300 35,900 39,900 4,800 54,600 66,600 0,500,500 5,500 7,00,500 7,000 9,400 30,500 40,500 5,500 00 AMBIENT 0 AMBIENT DE/DC/DS/DL 0-0 -5-0 -5-30 -40 3L44 4L44 5L44 6L44 8L44 9L44 0L44 L44 5L44 L44 9,00 35,600 4,900,00 60,700 70,00 77,400 83,00 03,500,500 4,00 8,400 33,700,00,500 56,00 6,800 67,000 89,00 00,00,300 5,00 30,00 33,800 4,900 50,000 55,00 59,800 77,900 89,900 8,700,000 6,600 9,700 37,800 44,300 49,600 53,00 70,600 79,500 6,00 9,300 3,300 5,900 33,00 39,000 43,700 46,800 54,500 7,600 4,000 6,600 0,300,400 9,000 34,00,000 40,800 5,400 63,500 0,000,900 4,800 6,300,500 5,800 8,000 9,00,900 49,00 DE/DC/DS/DL 0-0 -5-0 -5-30 -40 3L44 4L44 5L44 6L44 8L44 9L44 0L44 L44 5L44 L44 6,00 3,800 37,600 43,00 54,00 6,800 69,300 74,700 9,600 09,700,600 5,400 30,300 34,00 43,300 50,300 56,300 60,00 80,00 89,700 9,00,500 7,000 30,00,300 44,800 49,400 53,700 69,900 80,600 6,700 9,700 3,900 6,600 33,700 39,700 44,500 47,700 63,400 7,300 4,500 7,300,000 3,00 9,700 34,900 39,00 4,00,900 64,00,600 4,900 8,00 0,000 5,800 30,600 34,00 36,600 47,000 56,900 9,000 0,700 3,300 4,600 9,00 3,00 5,00 6,00 34,900 44,000 9

0 MODEL NUMBER DE/ DC/ DS/DL COMPRESSOR MODEL 30/3/60 COMP. COND. RLA LRA FLA TOTAL* UNIT AMPS MCA* 460/3/60 COMP. COND. RLA LRA FLA TOTAL* UNIT AMPS MCA* 5H 7H 8H 0H H 5H ELECTRICAL SPECIFICATIONS HIGH TEMP - R- DD-R63KE DA-R89KE 3DA-R0ME 3DB-RME 3DF-R5ME 3DS-R7ME.3 3.0 4.0 43.6. 59.6 0.0 69.0 5.0 5.0 75.0 75.0 0.5 4. 0.0 0.0 3.6 9.0 85.0 06.0 06.0.0.0. 7.5 39.4.4 53.0 57.6 69.0 34.0.0 59.0 64.0 70.0 84.0 3. 8.8 4.7 4.7 8.3 33.7 6.0 3.0 30.0 30.0 35.0 4.0 3L 4L 5L 6L 8L 9L 0L 5L L LOW TEMP - R- DF-F6KE DL-F0KE DA-F3KE 3DA-F8KE 3DB-F33KE 3DF-F40KE 3DS-F46KE 4DL-F63KE 4DT-F76KE 6.8 6.3 8.8 30.3 3.5 39.0 4.0 5.6 66.0 0.0 6.0 6.0 50.0 6.0 5.0 5.0 78.0 374.0 3. 3. 3. 8. 0. 0. 3.7 6. 6.9 8.6 6.3 33.0 5.0 77.0 83.0 06.0 06.0 39.0 87.0.....0 30.5 33.0 35.5.9 4 49.4 6.0 75.4 6.0.0 4.0 44.0 47.0 57.0 76.0 9.0 0.7.8.8 6.3 0.8.6 3.3 3.0 37.7 3.0 6.0 6.0 0.0 5.0 6.0 8.0.0 46.0 5M44 6M44 7M44 8M44 0M44 M44 5M44 MEDIUM TEMP - R-404A / R-507 DD-R63KE DL-R78KE DA-R89KE 3DA-R0ME 3DB-RME 3DF-R5ME 3DS-R7ME.3 3.6 3.0 4.0 43.6. 59.6 0.0 69.0 69.0 5.0 5.0 75.0 75.0 0.5 3.8 4. 0.0 0.0 3.6 9.0 85.0 85.0 06.0 06.0.0.0. 7.5 39.4 39.4.8 53.0 57.6 69.0 34.0 47.0.0 59.0 64.0 70.0 84.0 3. 8.5 8.8 4.7 4.7 8.3 33.7 6.0.0 3.0 30.0 30.0 35.0 4.0 3L44 4L44 5L44 6L44 8L44 9L44 0L44 L44 5L44 L44 LOW TEMP - R-404A / R-507 DF-F6KE DL-F0KE DA-F3KE 3DA-F8KE 3DB-F33KE 3DF-F40KE 3DS-F46KE 4DA-F47KE 4DL-F63KE 4DT-F76KE 6.8 6.3 8.8 30.3 3.5 39.0 4.0 45.6 5.6 66.0 0.0 6.0 6.0 50.0 6.0 5.0 5.0 0.0 78.0 374.0 3. 3. 3. 3. 8. 0. 0. 3.7 6. 6.9 8.6.8 6.3 33.0 5.0 77.0 83.0 06.0 06.0 0.0 39.0 87.0.....0 30.5 33.0 34.5.9 4 49.4 53.0 6.0 75.5 6.0.0 4.0 43.0 47.0 57.0 65.0 76.0 9.0 0.7.8.8 6.3 0.8.6 3.3 7.5 3.0 37.7 3.0 6.0 6.0 0.0 5.0 6.0 8.0 34.0.0 46.0 * Does not include evaporator electrical loads. MCA = Minimum Circuit Ampacity

70 740 805 840 30 75 75 30 40 APPROX. WEIGHT (LBS.) DE DC/DS/DL CONNECTION SIZE (In) LIQ. SUCT. REC. CAP @ 90% LBS. APPROXIMATE PHYSICAL DIMENSIONS (In) H L D DRW. NO.* 850 00 30 330 340 350 MODEL NUMBER DE/ DC/ DS/DL COMPRESSOR DATA 5H 7H 8H 0H H 5H PHYSICAL DATA HIGH TEMP - R- DD-R63KE DA-R89KE 3DA-R0ME 3DB-RME 3DF-R5ME 3DS-R7ME 3L 4L 5L 6L 8L 9L 0L 5L L LOW TEMP - R- DF-F6KE DL-F0KE DA-F3KE 3DA-F8KE 3DB-F33KE 3DF-F40KE 3DS-F46KE 4DL-F63KE 4DT-F76KE 5M44 6M44 7M44 8M44 0M44 M44 5M44 MEDIUM TEMP - R-404A / R-507 DD-R63KE DL-R78KE DA-R89KE 3DA-R0ME 3DB-RME 3DF-R5ME 3DS-R7ME 3L44 4L44 5L44 6L44 8L44 9L44 0L44 L44 5L44 L44 LOW TEMP - R-404A / R-507 DF-F6KE DL-F0KE DA-F3KE 3DA-F8KE 3DB-F33KE 3DF-F40KE 3DS-F46KE 4DA-F47KE 4DL-F63KE 4DT-F76KE COMP. MODEL CFH 83 35 375 60 93 0 44-3/4 3.0 6.0 6.0 6.0 6.0 96.0 580 740 760 900 90 90 -/8 - - - 904 008 9 375 60 95 0 300 3603 44-3/4 3.0 3.0 3.0 3.0 6.0 6.0 6.0 6.0 96.0 0 50 550 575 760 840 840 890 980 3/8 3/8 3/8 3/8 -/8 -/8 - - - -/8 850 075 00 30 330 330 350 83 008 35 375 60 95 0 44-3/4 7.0 7.0 5.0 5.0 5.0 5.0 8.0 580 650 740 760 900 900 90 -/8 -/8 - - - 70 760 805 870 30 75 75 90 30 40 904 008 9 375 60 95 0 0 300 3603 44-3/4 7.0 7.0 7.0 7.0 5.0 5.0 5.0 5.0 5.0 8.0 0 50 550 605 760 840 840 855 890 980 / / / / -/8 -/8 - - - - -/8 * See back cover.

DRAWINGS INDOOR UNITS OUTDOOR UNITS P/N 30000 0/07 R-50 See Physical Data page for the appropriate number of condenser fans. 3050 Enterprise St., P.O. Box 030, Brea, CA. 98-030 Tel (74)59-935 Fax (74)59-703